1.
Phys Imaging Radiat Oncol ; 31: 100621, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39220113

ABSTRACT

Proton therapy (PT) is an advancing radiotherapy modality increasingly integrated into clinical settings, transitioning from research facilities to hospital environments. A critical aspect of the commissioning of a proton pencil beam scanning delivery system is the acquisition of experimental beam data for accurate beam modelling within the treatment planning system (TPS). These guidelines describe in detail the acquisition of proton pencil beam modelling data. First, it outlines the intrinsic characteristics of a proton pencil beam-energy distribution, angular-spatial distribution and particle number. Then, it lists the input data typically requested by TPSs. Finally, it describes in detail the set of experimental measurements recommended for the acquisition of proton pencil beam modelling data-integrated depth-dose curves, spot maps in air, and reference dosimetry. The rigorous characterization of these beam parameters is essential for ensuring the safe and precise delivery of proton therapy treatments.

2.
Crit Rev Oncol Hematol ; 202: 104463, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39098367

ABSTRACT

The role of external beam radiotherapy (EBRT) in thyroid cancer (TC) remains contentious due to limited data. Retrospective studies suggest adjuvant EBRT benefits high-risk differentiated thyroid cancer (DTC) and limited-stage anaplastic thyroid carcinoma (ATC), enhancing locoregional control and progression-free survival when combined with surgery and chemotherapy. Intensity-modulated radiotherapy (IMRT) and particle therapy (PT), including protons, carbon ions, and Boron Neutron Capture Therapy (BNCT), represent advances in TC treatment. Following PRISMA guidelines, we reviewed 471 studies from January 2002 to January 2024, selecting 14 articles (10 preclinical, 4 clinical). Preclinical research focused on BNCT in ATC mouse models, showing promising local control rates. Clinical studies explored proton, neutron, or photon radiotherapy, reporting favorable outcomes and manageable toxicity. While PT shows promise supported by biological rationale, further research is necessary to clarify its role and potential combination with systemic treatments in TC management.


Subject(s)
Thyroid Neoplasms , Thyroid Neoplasms/radiotherapy , Thyroid Neoplasms/pathology , Humans , Animals , Heavy Ion Radiotherapy/methods , Proton Therapy/methods , Radiotherapy, Intensity-Modulated/methods , Boron Neutron Capture Therapy/methods
3.
Phys Imaging Radiat Oncol ; 31: 100624, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39206357

ABSTRACT

Background and Purpose: A low linear energy transfer (LET) in the target can reduce the effectiveness of carbon ion radiotherapy (CIRT). This study aimed at exploring benefits and limitations of LET optimization for large sacral chordomas (SC) undergoing CIRT. Materials and Methods: Seventeen cases were used to tune LET-based optimization, and seven to independently test interfraction plan robustness. For each patient, a reference plan was optimized on biologically-weighted dose cost functions. For the first group, 7 LET-optimized plans were obtained by increasing the gross tumor volume (GTV) minimum LETd (minLETd) in the range 37-55 keV/µm, in steps of 3 keV/µm. The optimal LET-optimized plan (LETOPT) was the one maximizing LETd, while adhering to clinical acceptability criteria. Reference and LETOPT plans were compared through dose and LETd metrics (D x , L x to x% volume) for the GTV, clinical target volume (CTV), and organs at risk (OARs). The 7 held-out cases were optimized setting minLETd to the average GTV L98% of the investigation cohort. Both reference and LETOPT plans were recalculated on re-evaluation CTs and compared. Results: GTV L98% increased from (31.8 ± 2.5)keV/µm to (47.6 ± 3.1)keV/µm on the LETOPT plans, while the fraction of GTV receiving over 50 keV/µm increased on average by 36% (p < 0.001), without affecting target coverage goals, or impacting LETd and dose to OARs. The interfraction analysis showed no significant worsening with minLETd set to 48 keV/µm. Conclusion: LETd optimization for large SC could boost the LETd in the GTV without significantly compromising plan quality, potentially improving the therapeutic effects of CIRT for large radioresistant tumors.

4.
Cancers (Basel) ; 16(14)2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39061220

ABSTRACT

INTRODUCTION: Decellularized extracellular matrix (ECM) bioscaffolds have emerged as a promising three-dimensional (3D) model, but so far there are no data concerning their use in radiobiological studies. MATERIAL AND METHODS: We seeded two well-known radioresistant cell lines (HMV-II and PANC-1) in decellularized porcine liver-derived scaffolds and irradiated them with both high- (Carbon Ions) and low- (Photons) Linear Energy Transfer (LET) radiation in order to test whether a natural 3D-bioscaffold might be a useful tool for radiobiological research and to achieve an evaluation that could be as near as possible to what happens in vivo. RESULTS: Biological scaffolds provided a favorable 3D environment for cell proliferation and expansion. Cells did not show signs of dedifferentiation and retained their distinct phenotype coherently with their anatomopathological and clinical behaviors. The radiobiological response to high LET was higher for HMV-II and PANC-1 compared to the low LET. In particular, Carbon Ions reduced the melanogenesis in HMV-II and induced more cytopathic effects and the substantial cell deterioration of both cell lines compared to photons. CONCLUSIONS: In addition to offering a suitable 3D model for radiobiological research and an appropriate setting for preclinical oncological analysis, we can attest that bioscaffolds seemed cost-effective due to their ease of use, low maintenance requirements, and lack of complex technology.

5.
Phys Med ; 124: 103421, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38968695

ABSTRACT

PURPOSE: To investigate the role of dosiomics features extracted from physical dose (DPHYS), RBE-weighted dose (DRBE) and dose-averaged Linear Energy Transfer (LETd), to predict the risk of local recurrence (LR) in skull base chordoma (SBC) treated with Carbon Ion Radiotherapy (CIRT). Thus, define and evaluate dosiomics-driven tumor control probability (TCP) models. MATERIALS AND METHODS: 54 SBC patients were retrospectively selected for this study. A regularized Cox proportional hazard model (r-Cox) and Survival Support Vector Machine (s-SVM) were tuned within a repeated Cross Validation (CV) and patients were stratified in low/high risk of LR. Models' performance was evaluated through Harrell's concordance statistic (C-index), and survival was represented through Kaplan-Meier (KM) curves. A multivariable logistic regression was fit to the selected feature sets to generate a dosiomics-driven TCP model for each map. These were compared to a reference model built with clinical parameters in terms of f-score and accuracy. RESULTS: The LETd maps reached a test C-index of 0.750 and 0.786 with r-Cox and s-SVM, and significantly separated KM curves. DPHYS maps and clinical parameters showed promising CV outcomes with C-index above 0.8, despite a poorer performance on the test set and patients stratification. The LETd-based TCP showed a significatively higher f-score (0.67[0.52-0.70], median[IQR]) compared to the clinical model (0.4[0.32-0.63], p < 0.025), while DPHYS achieved a significatively higher accuracy (DPHYS: 0.73[0.65-0.79], Clinical: 0.6 [0.52-0.72]). CONCLUSION: This analysis supports the role of LETd as relevant source of prognostic factors for LR in SBC treated with CIRT. This is reflected in the TCP modeling, where LETd and DPHYS showed an improved performance with respect to clinical models.


Subject(s)
Chordoma , Heavy Ion Radiotherapy , Skull Base Neoplasms , Chordoma/radiotherapy , Skull Base Neoplasms/radiotherapy , Humans , Treatment Outcome , Male , Female , Middle Aged , Retrospective Studies , Radiometry , Adult , Aged , Radiotherapy Dosage , Linear Energy Transfer , Proportional Hazards Models , Neoplasm Recurrence, Local/radiotherapy , Support Vector Machine
6.
Phys Med Biol ; 69(11)2024 May 14.
Article in English | MEDLINE | ID: mdl-38663410

ABSTRACT

Objective. This study characterized optically-stimulated luminescent dosimeter (OSLD) nanoDots for use in a therapeutic carbon beam using the Imaging and Radiation Oncology Core (IROC) framework for remote output verification.Approach. The absorbed dose correction factors for OSLD (fading, linearity, beam quality, angularity, and depletion), as defined by AAPM TG 191, were characterized for carbon beams. For the various correction factors, the effect of linear energy transfer (LET) was examined by characterizing in both a low and high LET setting.Main results. Fading was not statistically different between reference photons and carbon, nor between low and high LET beams; thus, the standard IROC-defined exponential function could be used to characterize fading. Dose linearity was characterized with a linear fit; while low and high LET carbon linearity was different, these differences were small and could be rolled into the uncertainty budget if using a single linearity correction. A linear fit between beam quality and dose-averaged LET was determined. The OSLD response at various angles of incidence was not statistically different, thus a correction factor need not be applied. There was a difference in depletion between low and high LET irradiations in a primary carbon beam, but this difference was small over the standard five readings. The largest uncertainty associated with the use of OSLDs in carbon was because of thekQcorrection factor, with an uncertainty of 6.0%. The overall uncertainty budget was 6.3% for standard irradiation conditions.Significance. OSLD nanoDot response was characterized in a therapeutic carbon beam. The uncertainty was larger than for traditional photon applications. These findings enable the use of OSLDs for carbon absorbed dose measurements, but with less accuracy than conventional OSLD audit programs.


Subject(s)
Carbon , Carbon/chemistry , Carbon/therapeutic use , Radiometry/methods , Linear Energy Transfer , Uncertainty , Optically Stimulated Luminescence Dosimetry/methods , Radiotherapy Dosage , Humans
7.
Med Phys ; 51(5): 3782-3795, 2024 May.
Article in English | MEDLINE | ID: mdl-38569067

ABSTRACT

BACKGROUND: Interpatient variation of tumor radiosensitivity is rarely considered during the treatment planning process despite its known significance for the therapeutic outcome. PURPOSE: To apply our mechanistic biophysical model to investigate the biological robustness of carbon ion radiotherapy (CIRT) against DNA damage repair interference (DDRi) associated patient-to-patient variability in radiosensitivity and its potential clinical advantages against conventional radiotherapy approaches. METHODS AND MATERIALS: The "UNIfied and VERSatile bio response Engine" (UNIVERSE) was extended by carbon ions and its predictions were compared to a panel of in vitro and in vivo data including various endpoints and DDRi settings within clinically relevant dose and linear energy transfer (LET) ranges. The implications of UNIVERSE predictions were then assessed in a clinical patient scenario considering DDRi variance. RESULTS: UNIVERSE tests well against the applied benchmarks. While in vitro survival curves were predicted with an R2 > 0.92, deviations from in vivo RBE data were less than 5.6% The conducted paradigmatic patient plan study implies a markedly reduced significance of DDRi based radiosensitivity variability in CIRT (13% change of D 50 ${{D}_{50}}$ in target) compared to conventional radiotherapy (62%) and that boosting the LET within the target further amplifies this robustness of CIRT (8%). In the case of heightened tumor radiosensitivity, a dose de-escalation strategy for photons allows a reduction of the maximum effective dose within the normal tissue (NT) from a D 2 ${{D}_2}$ of 2.65 to 1.64 Gy, which lies below the level found for CIRT ( D 2 ${{D}_2}$  = 2.41 Gy) for the analyzed plan and parameters. However, even after de-escalation, the integral effective dose in the NT is found to be substantially higher for conventional radiotherapy in comparison to CIRT ( D m e a n ${{D}_{mean}}$ of 0.75, 0.46, and 0.24 Gy for the conventional plan, its de-escalation and CIRT, respectively). CONCLUSIONS: The framework offers adequate predictions of in vitro and in vivo radiation effects of CIRT while allowing the consideration of DRRi based solely on parameters derived from photon data. The results of the patient planning study underline the potential of CIRT to minimize important sources of interpatient divergence in therapy outcome, especially when combined with techniques that allow to maximize the LET within the tumor. Despite the potential of de-escalation strategies for conventional radiotherapy to reduce the maximum effective dose in the NT, CIRT appears to remain a more favorable option due to its ability to reduce the integral effective dose within the NT.


Subject(s)
DNA Damage , DNA Repair , Heavy Ion Radiotherapy , Radiation Tolerance , Humans , DNA Repair/radiation effects , Models, Biological , Linear Energy Transfer
8.
Sleep Med ; 118: 29-31, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38581805

ABSTRACT

BACKGROUND: ABGAs are historically associated with Encephalitis Lethargica (EL). Typically ABGAs are also found in children resulting in a variety of neuropsychiatric and extrapyramidal disorders, rare cases are reported in adults with atypical movement disorders. No description of basal ganglia reversible lesions related to ABGAs are reported and these antibodies are not included in the list of autoimmune encephalitis. METHODS AND RESULTS: A 55 years old female presented sub-acute onset of an anxious-depressive disorder and obsessive-compulsive behavior associated with intractable insomnia affecting sleep onset and sleep maintenance. Brain-MRI showed diffuse hyperintensities on FLAIR sequences in the basal ganglia. A therapy with IV-immunoglobulin was started and the clinical condition improved dramatically and insomnia and psychiatric symptoms resolved completely. CONCLUSION: Our case highlights the importance of making a fast diagnosis. When caught early ABGAs-related encephalitis is susceptible of a good outcome and response to treatment. Reversible insomnia and dementia in our case expand ABGA clinical presentation in adults and favors the hypothesis of an immune pathogenesis for Encephalitis Lethargica, especially in the hyperkinetic form as previously suggested, as in our case.


Subject(s)
Dementia , Encephalitis , Sleep Initiation and Maintenance Disorders , Humans , Female , Sleep Initiation and Maintenance Disorders/etiology , Middle Aged , Dementia/complications , Dementia/etiology , Encephalitis/complications , Magnetic Resonance Imaging
9.
Epilepsia ; 65(6): 1560-1567, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38507275

ABSTRACT

In status epilepticus (SE), "time is brain." Currently, first-line therapy consists of benzodiazepines (BDZs) and SE is classified by the response to treatment; stage 2 or established SE is defined as "BDZ-resistant SE." Nonetheless, this classification does not always work, especially in the case of prolonged convulsive SE, where many molecular changes occur and γ-aminobutyric acid signaling becomes excitatory. Under these circumstances, BDZ therapy might not be optimal, and might be possibly detrimental, if given alone; as the duration of SE increases, so too does BDZ resistance. Murine models of SE showed how these cases might benefit more from synergistic combined therapy from the start. The definition of Stage 1 plus is suggested, as a stage requiring combined therapy from the start, which includes prolonged SE with seizure activity going on for >10 min, the time that marks the disruption of receptor homeostasis, with increased internalization. This specific stage might require a synergistic approach from the start, with a combination of first- and second-line treatment.


Subject(s)
Anticonvulsants , Status Epilepticus , Status Epilepticus/drug therapy , Status Epilepticus/physiopathology , Humans , Animals , Anticonvulsants/therapeutic use , Benzodiazepines/therapeutic use , Mice
10.
J Neurol Sci ; 457: 122882, 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38224629

ABSTRACT

BACKGROUND AND OBJECTIVES: Many reversible brain MRI abnormalities have been described, among these the most frequently reported are cortical hyperintensities on FLAIR/T2 occurring during seizures. Much less attention has been given to those situations where White Matter goes Dark: subcortical white matter hypointensity on T2/FLAIR. Our aim is to identify the medical condition "Dark White Matter" (DWM) is more frequently associated with. This is the first systematic review on DWM. METHODS: PubMed was searched in August 2023. Included studies were those reporting Diffuse Subcortical White Matter Hypointensity on T2/FLAIR. Mainly case reports were included. Individual patient-level data was included whenever available. Frequency measures of the different diseases were calculated. RESULTS: 56 studies were included, 228 patients were eligible for analysis. DWM happened in isolation, with no cortical abnormalities, in 71 cases and was associated with seizures in >61.4% of cases. The most frequently DWM-associated disease was Non-Ketotic Hyperglycaemic hyperosmolar state (NKH), followed by Encephalitis, Moyamoya disease, Genetic Causes, and Subdural Hematoma. Frequency of NKH was 32%. NKH was associated with seizures in 100% of cases and the most frequently involved lobe was the occipital one. When considering only the subgroup of patients with seizures, DWM was indicative of NKH in 51.4% of cases and Encephalitis in 26.4% of cases. Key limitations are heterogeneity and missing data. DISCUSSION: DWM is frequently underdiagnosed. This sign can exist alone and it is not merely a consequence of cortical involvement. Moreover, it has important implications, both diagnostic and therapeutic, as it is more frequently associated with NKH, especially in the context of seizures, where anti-seizure medication is not the first line of treatment. We also discuss the pathogenesis of DWM by finding a common link between the most frequently associated diseases.


Subject(s)
Encephalitis , Leukoencephalopathies , Moyamoya Disease , White Matter , Humans , White Matter/diagnostic imaging , Magnetic Resonance Imaging , Leukoencephalopathies/diagnostic imaging
11.
Sci Rep ; 14(1): 418, 2024 01 03.
Article in English | MEDLINE | ID: mdl-38172585

ABSTRACT

Boron Neutron Capture Therapy (BNCT) is a radiotherapy technique based on the enrichment of tumour cells with suitable 10-boron concentration and on subsequent neutron irradiation. Low-energy neutron irradiation produces a localized deposition of radiation dose caused by boron neutron capture reactions. Boron is vehiculated into tumour cells via proper borated formulations, able to accumulate in the malignancy more than in normal tissues. The neutron capture releases two high-LET charged particles (i.e., an alpha particle and a lithium ion), losing their energy in a distance comparable to the average dimension of one cell. Thus BNCT is selective at the cell level and characterized by high biological effectiveness. As the radiation field is due to the interaction of neutrons with the components of biological tissues and with boron, the dosimetry requires a formalism to express the absorbed dose into photon-equivalent units. This work analyzes a clinical case of an adenoid cystic carcinoma treated with carbon-ion radiotherapy (CIRT), located close to optic nerve and deep-seated as a practical example of how to apply the formalism of BNCT photon isoeffective dose and how to evaluate the BNCT dose distribution against CIRT. The example allows presenting different dosimetrical and radiobiological quantities and drawing conclusions on the potential of BNCT stemming on the clinical result of the CIRT. The patient received CIRT with a dose constraint on the optic nerve, affecting the peripheral part of the Planning Target Volume (PTV). After the treatment, the tumour recurred in this low-dose region. BNCT was simulated for the primary tumour, with the goal to calculate the dose distribution in isoeffective units and a Tumour Control Probability (TCP) to be compared with the one of the original treatment. BNCT was then evaluated for the recurrence in the underdosed region which was not optimally covered by charged particles due to the proximity of the optic nerve. Finally, a combined treatment consisting in BNCT and carbon ion therapy was considered to show the consistency and the potential of the model. For the primary tumour, the photon isoeffective dose distribution due to BNCT was evaluated and the resulted TCP was higher than that obtained for the CIRT. The formalism produced values that are consistent with those of carbon-ion. For the recurrence, BNCT dosimetry produces a similar TCP than that of primary tumour. A combined treatment was finally simulated, showing a TCP comparable to the BNCT-alone with overall dosimetric advantage in the most peripheral parts of the treatment volume. Isoeffective dose formalism is a robust tool to analyze BNCT dosimetry and to compare it with the photon-equivalent dose calculated for carbon-ion treatment. This study introduces for the first time the possibility to combine the dosimetry obtained by two different treatment modalities, showing the potential of exploiting the cellular targeting of BNCT combined with the precision of charged particles in delivering an homogeneous dose distribution in deep-seated tumours.


Subject(s)
Boron Neutron Capture Therapy , Head and Neck Neoplasms , Heavy Ion Radiotherapy , Humans , Boron Neutron Capture Therapy/methods , Boron , Carbon , Neutrons
12.
Neurol Sci ; 45(2): 825-826, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37828390

ABSTRACT

A 78-year-old woman without past relevant medical history presented to the emergency department for acute transient dysarthria. NIHSS was 0/42. Neurological examination revealed chorea-like movements over the left limbs, especially the foot. No other neurological signs were present. CT perfusion showed right cortical hypoperfusion due to right M2 occlusion, basal-ganglia perfusion was normal. Brain MRI revealed a small focus of restricted diffusion in the right insula, sparing basal ganglia. Based on the neuroimaging features and clinical correlation, despite the NIHSS score, we decided to treat the patient with alteplase, after iv-thrombolysis hyperkinetic movements ceased completely. Brain-MRI performed 72 h after symptom onset confirmed a confined insular ischemic lesion without the involvement of deep gray matter structures. Hyperkinetic movement disorders, such as hemichorea hemiballismus, are rare presentations of stroke, basal ganglia are mainly involved even if the insular cortex has been described too. Clinical decision on whether to treat ischemic stroke does not include movement disorders. Our case underscores NIHSS limitations in clinical practice.


Subject(s)
Chorea , Dyskinesias , Movement Disorders , Stroke , Female , Humans , Aged , Stroke/complications , Stroke/diagnostic imaging , Chorea/diagnosis , Tissue Plasminogen Activator
13.
Toxins (Basel) ; 15(5)2023 05 09.
Article in English | MEDLINE | ID: mdl-37235358

ABSTRACT

In this randomized, double-blind, placebo-controlled study, we evaluated the efficacy of an individualized technique of subcutaneous injection of botulinum toxin type A (BoNT-A) targeted (SjBoT) to the occipital or trigeminal skin area in non-responder patients with chronic migraine (CM). Patients who had not previously responded to at least two treatments of intramuscular injections of BoNT-A were randomly assigned (2:1) to receive two subcutaneous administrations of BoNT-A (up to 200 units) with the SjBoT injection paradigm or placebo. Following the skin area where the maximum pain began, treatment was given in the trigeminal or occipital region bilaterally. The primary endpoint changed in monthly headache days from baseline to the last 4 weeks. Among 139 randomized patients, 90 received BoNT-A and 49 received placebo, and 128 completed the double-blind phase. BoNT-A significantly reduced monthly headache days versus placebo (-13.2 versus -1.2; p < 0.0001) in the majority of patients who had cutaneous allodynia. Other secondary endpoints, including measures for disability (Migraine Disability Assessment questionnaire from baseline 21.96 to 7.59 after treatment, p = 0.028), also differed. Thus, in non-responder patients with CM, BoNT-A significantly reduced migraine days when administered according to the "follow the origin of maximum pain" approach using SjBoT injection paradigm.


Subject(s)
Botulinum Toxins, Type A , Migraine Disorders , Neuromuscular Agents , Humans , Botulinum Toxins, Type A/therapeutic use , Treatment Outcome , Migraine Disorders/drug therapy , Headache/drug therapy , Double-Blind Method , Injections, Subcutaneous , Neuromuscular Agents/therapeutic use
14.
J Clin Med ; 12(7)2023 Mar 31.
Article in English | MEDLINE | ID: mdl-37048714

ABSTRACT

Sinonasal cancers (SNCs) are rare and heterogeneous in histology and biological behavior. The prognosis is generally unfavorable, especially in inoperable cases. In recent years, for some histologies, such as undifferentiated sinonasal carcinoma (SNUC), multimodal treatment with a combination of induction chemotherapy, surgery, and chemo/radiotherapy (RT) has improved the prognosis. Nevertheless, still about half of the patients treated incur a recurrence, in most of the cases at the local site. Surgery with and without RT is usually the treatment choice in cases of recurrence after previous RT in combination with systemic therapy or RT in a histology-driven fashion. In the case of inoperable disease or contraindications to surgery, RT is still a valid treatment option. In this context, hadron therapy with protons (PT) or carbon ions (CIRT) is often preferred due to the physical and biological characteristics of charged particles, allowing the administration of high doses to the tumor target while sparing the surrounding healthy tissues and potentially limiting the side effects due to the high cumulative dose. In the absence of a standard of care for the recurrent setting, we aimed to investigate the role of re-RT with PT or CIRT. We retrospectively analysed 15 patients with recurrent, previously irradiated, SNCs treated at our institution between 2013 and 2020. Local control (LC) and overall survival (OS) were estimated by the Kaplan-Meier method. Acute and late toxicities were scored according to the National Cancer Institute's Common Terminology Criteria for Adverse Events CTCAE version 5.0. A total of 13 patients received CIRT and 2 patients received PT. The median re-RT dose was 54 GyRBE (range 45-64 GyRBE) delivered in 3 or 4 GyRBE/fr (fraction) for the CIRT, and 2 Gy RBE/fr for the PT schedule. LC was 44% at the 1-year follow-up and 35.2% at the 3-year follow-up. OS at 1 and 3 years were 92.9% and 38.2%, respectively. Fourteen patients developed G1-G2 acute toxicity (dermatitis and mucositis), and no patients developed G3-G5. Regarding late toxicity, 10 patients encountered at maximum G1-2 events, and 4 did not experience any toxicity. Only for one patient G3 late toxicity was reported (dysphagia requiring a percutaneous endoscopic gastrostomy).

15.
Life (Basel) ; 13(3)2023 Mar 15.
Article in English | MEDLINE | ID: mdl-36983949

ABSTRACT

Primary mucosal melanoma (PMM) and pancreatic ductal adenocarcinoma (PDAC) are two aggressive malignancies, characterized by intrinsic radio-chemoresistance and neurotropism, a histological feature resulting in frequent perineural invasion (PNI), supported by neurotrophic factors secreted in the tumour microenvironment (TME), such as neurotrophin-3 (NT-3). Carbon-ion radiotherapy (CIRT) could represent an effective option in unresectable PMM and PDAC. Only a few data about the effects of CIRT on PNI in relation to NT-3 are available in the literature, despite the numerous pieces of evidence revealing the peculiar effects of this type of radiation on tumour cell migration. This in vitro study investigated for the first time the response of PMM and PDAC cells to NT-3 and evaluated the effects of conventional photon beam radiotherapy (XRT) and CIRT on cell viability, proliferation, and migration. Our results demonstrated the greater capacity of C-ions to generally decrease cell viability, proliferation, and migration, while the addition of NT-3 after both types of irradiation determined an increase in these features, maintaining a dose-dependent trend and acting more effectively as a chemoattractant than inductor in the case of migration.

16.
Phys Med ; 107: 102561, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36898300

ABSTRACT

PURPOSE: To fully characterize the flat panel detector of the new Sphinx Compact device with scanned proton and carbon ion beams. MATERIALS AND METHODS: The Sphinx Compact is designed for daily QA in particle therapy. We tested its repeatability and dose rate dependence as well as its proportionality with an increasing number of particles and potential quenching effect. Potential radiation damage was evaluated. Finally, we compared the spot characterization (position and profile FWHM) with our radiochromic EBT3 film baseline. RESULTS: The detector showed a repeatability of 1.7% and 0.9% for single spots of protons and carbon ions, respectively, while for small scanned fields it was inferior to 0.2% for both particles. The response was independent from the dose rate (difference from nominal value < 1.5%). We observed an under-response due to quenching effect for both particles, mostly for carbon ions. No radiation damage effects were observed after two months of weekly use and approximately 1350 Gy delivered to the detector. Good agreement was found between the Sphinx and EBT3 films for the spot position (central-axis deviation within 1 mm). The spot size measured with the Sphinx was larger compared to films. For protons, the average and maximum differences over different energies were 0.4 mm (3%) and 1 mm (7%); for carbon ions they were 0.2 mm (4%) and 0.4 mm (6%). CONCLUSIONS: Despite the quenching effect the Sphinx Compact fulfills the requirements needed for constancy checks and could represent a time-saving tool for daily QA in scanned particle beams.


Subject(s)
Proton Therapy , Protons , Radiometry , Carbon , Film Dosimetry
17.
Neuroradiol J ; 36(5): 614-615, 2023 Oct.
Article in English | MEDLINE | ID: mdl-36607067

ABSTRACT

Ecchordosis physaliphora (EP) is a rare benign congenital hamartomatous lesion originating from remnants of the notochord. EP has never been associated with hypnic headache before. We report for the first time two cases of EP associated with an hypnic headache. The latter is a form of sleep-related nocturnal headache whose pathogenesis has not been fully elucidated. A 61-year-old woman and a 41-year-old man had been complaining of a dull headache that woke them up every night for many months. In both cases, an enlarged cystic lesion in the prepontine cistern, compatible with ecchordosis physaliphora, was found on brain MRI. A diagnosis of hypnic headache secondary to EP was made. Ecchordosis physaliphora presenting as hypnic headache had never been described before. The low prevalence of both conditions (EP and HH) and their presence in two cases might suggest a possible causal association between the two conditions.


Subject(s)
Hamartoma , Male , Female , Humans , Middle Aged , Adult , Headache/diagnostic imaging , Headache/etiology , Subarachnoid Space/pathology , Magnetic Resonance Imaging , Notochord/pathology
18.
J Neurol ; 270(2): 595-600, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36229702

ABSTRACT

BACKGROUND: Many patients treated with Natalizumab experience wearing-off symptoms (WoS) towards the end of the administration cycle. During the pandemic we advised and asked patients undergoing treatment with Natalizumab if they wanted to be shifted from a standard interval dosing (StID of 4 weeks) to an extended interval dosing (ExID of 5-6 weeks), regardless of their JCV index. Our main objective was to study prevalence and incidence of WoS when ExID was adopted. METHODS: We enrolled 86 patients, from May 2020 to January 2021, evaluated at baseline and during a 6 months follow-up with a survey focused on WoS, Fatigue Severity Scale (FSS), Expanded Disability Status Scale (EDSS) and MRI. RESULTS: Among the 86 patients, 32 (37.2%) reported WoS. Most common one was fatigue (93.7%). Mean EDSS was higher in the group reporting WoS (3.8 WoS vs 3.1 non-WoS, p < 0.05). Sphincterial function was the EDSS item that significantly differed between the WoS group and the non-WoS group (1.4 WoS vs 0.6 non-WoS, p < 0.001). WoS correlate with the FSS scale (p < 0.001). CONCLUSION: Adopting an extended interval dosing does not result in significantly different occurrence of WoS between the ExID and the StID populations, in our cohort of patients. Interestingly, there is a strong correlation between WoS and a higher EDSS and FSS. Safety and efficacy of Natalizumab with ExID are relatively preserved in our study.


Subject(s)
COVID-19 , Multiple Sclerosis, Relapsing-Remitting , Multiple Sclerosis , Humans , Natalizumab/adverse effects , SARS-CoV-2 , Immunologic Factors/adverse effects , Pandemics , Multiple Sclerosis, Relapsing-Remitting/chemically induced , Multiple Sclerosis/drug therapy , Multiple Sclerosis/epidemiology , Multiple Sclerosis/chemically induced
19.
Interv Neuroradiol ; : 15910199221143181, 2022 Dec 19.
Article in English | MEDLINE | ID: mdl-36536607
20.
Med Phys ; 49(12): 7802-7814, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36196033

ABSTRACT

BACKGROUND: With rapid evolutions of fast and sophisticated calculation techniques and delivery technologies, clinics are almost facing a daily patient-specific (PS) plan adaptation, which would make a conventional experimental quality assurance (QA) workflow unlikely to be routinely feasible. Therefore, in silico approaches are foreseen by means of second-check independent dose calculation systems possibly handling machine log-files. PURPOSE: To validate the in-house developed GPU-dose engine, FRoG, for light ion beam therapy (protons and carbon ions) as a second-check independent calculation system and to integrate machine log-file analysis into the patient-specific quality assurance (PSQA) program. METHODS: Spot sizes, depth-dose distributions, and absolute dose calibrations were configured into FRoG and a set of nine regular-shaped targets in combination with more than 170 clinical treatment fields were tested against pinpoint ionization chamber measurements. Both the treatment planning system DICOM RTplans and machine treatment log-files were used as input for the dose kernel in water, and a 3D local γ (1 mm/2%) index was used as the main evaluation metric. RESULTS: Calculated configuration data matched experimental measurements with submillimetric agreement. For regular-shaped targets, the unsigned average relative difference between calculated and measured dose values was less than 2% for both protons and carbon ions. The mean γ passing rate (PR) was around 98% for both particle species. For clinical treatment beams, DICOM-based recalculations showed a γ-PR more than 99% for both particle species. The same level of agreement was preserved for protons when moving to log-file-based recalculations. A score of around 95% was registered for carbon ion beams, once excluding low-quality machine log-files. Unsigned average relative difference against acquired data was less than 2% also for real clinical beams. CONCLUSIONS: FRoG was proven as an accurate and reliable tool for PSQA in scanning light ion beam therapy. The proposed method allows for an extremely efficient workflow, without compromising the quality of the plan verification procedure.


Subject(s)
Protons , Radiometry , Humans , Radiotherapy Dosage , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Quality Assurance, Health Care/methods , Monte Carlo Method