Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 124
Filter
1.
J Biomed Opt ; 29(6): 067001, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38826808

ABSTRACT

Significance: In the realm of cerebrovascular monitoring, primary metrics typically include blood pressure, which influences cerebral blood flow (CBF) and is contingent upon vessel radius. Measuring CBF noninvasively poses a persistent challenge, primarily attributed to the difficulty of accessing and obtaining signal from the brain. Aim: Our study aims to introduce a compact speckle contrast optical spectroscopy device for noninvasive CBF measurements at long source-to-detector distances, offering cost-effectiveness, and scalability while tracking blood flow (BF) with remarkable sensitivity and temporal resolution. Approach: The wearable sensor module consists solely of a laser diode and a board camera. It can be easily placed on a subject's head to measure BF at a sampling rate of 80 Hz. Results: Compared to the single-fiber-based version, the proposed device achieved a signal gain of about 70 times, showed superior stability, reproducibility, and signal-to-noise ratio for measuring BF at long source-to-detector distances. The device can be distributed in multiple configurations around the head. Conclusions: Given its cost-effectiveness, scalability, and simplicity, this laser-centric tool offers significant potential in advancing noninvasive cerebral monitoring technologies.


Subject(s)
Cerebrovascular Circulation , Equipment Design , Spectrum Analysis , Humans , Cerebrovascular Circulation/physiology , Spectrum Analysis/instrumentation , Cost-Benefit Analysis , Reproducibility of Results , Wearable Electronic Devices , Signal-To-Noise Ratio , Lasers , Brain/blood supply , Brain/diagnostic imaging , Brain/physiology , Laser Speckle Contrast Imaging/instrumentation
2.
Ann Emerg Med ; 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38888531

ABSTRACT

STUDY OBJECTIVE: The real-world effectiveness and safety of a 0/1-hour accelerated protocol using high-sensitivity cardiac troponin (hs-cTn) to exclude myocardial infarction (MI) compared to routine care in the United States is uncertain. The objective was to compare a 0/1-hour accelerated protocol for evaluation of MI to a 0/3-hour standard care protocol. METHODS: The RACE-IT trial was a stepped-wedge, randomized trial across 9 emergency departments (EDs) that enrolled 32,609 patients evaluated for possible MI from July 2020 through April 2021. Patients undergoing high-sensitivity cardiac troponin I testing with concentrations less than or equal to 99th percentile were included. Patients who had MI excluded by the 0/1-hour protocol could be discharged from the ED. Patients in the standard care protocol had 0- and 3-hour troponin testing and application of a modified HEART score to be eligible for discharge. The primary endpoint was the proportion of patients discharged from the ED without 30-day death or MI. RESULTS: There were 13,505 and 19,104 patients evaluated in the standard care and accelerated protocol groups, respectively, of whom 19,152 (58.7%) were discharged directly from the ED. There was no significant difference in safe discharges between standard care and the accelerated protocol (59.5% vs 57.8%; adjusted odds ratio (aOR)=1.05, 95% confidence interval [CI] 0.95 to 1.16). At 30 days, there were 90 deaths or MIs with 38 (0.4%) in the standard care group and 52 (0.4%) in the accelerated protocol group (aOR=0.84, 95% CI 0.43 to 1.68). CONCLUSION: A 0/1-hour accelerated protocol using high-sensitivity cardiac troponin I did not lead to more safe ED discharges compared with standard care.

3.
Prehosp Emerg Care ; : 1-9, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38713769

ABSTRACT

BACKGROUND: A single dose epinephrine protocol (SDEP) for out-of-hospital cardiac arrest (OHCA) achieves similar survival to hospital discharge (SHD) rates as a multidose epinephrine protocol (MDEP). However, it is unknown if a SDEP improves SHD rates among patients with a shockable rhythm or those receiving bystander cardiopulmonary resuscitation (CPR). METHODS: This pre-post study, spanning 11/01/2016-10/29/2019 at 5 North Carolina EMS systems, compared pre-implementation MDEP and post-implementation SDEP in patients ≥18 years old with non-traumatic OHCA. Data on initial rhythm type, performance of bystander CPR, and the primary outcome of SHD were sourced from the Cardiac Arrest Registry to Enhance Survival. We compared SDEP vs MDEP performance in each rhythm (shockable and non-shockable) and CPR (bystander CPR or no bystander CPR) subgroup using Generalized Estimating Equations to account for clustering among EMS systems and to adjust for age, sex, race, witnessed arrest, arrest location, AED availability, EMS response interval, and presence of a shockable rhythm or receiving bystander CPR. The interaction of SDEP implementation with rhythm type and bystander CPR was evaluated. RESULTS: Of 1690 patients accrued (899 MDEP, 791 SDEP), 19.2% (324/1690) had shockable rhythms and 38.9% (658/1690) received bystander CPR. After adjusting for confounders, SHD was increased after SDEP implementation among patients with bystander CPR (aOR 1.61, 95%CI 1.03-2.53). However, SHD was similar in the SDEP cohort vs MDEP cohort among patients without bystander CPR (aOR 0.81, 95%CI 0.60-1.09), with a shockable rhythm (aOR 0.96, 95%CI 0.48-1.91), and with a non-shockable rhythm (aOR 1.26, 95%CI 0.89-1.77). In the adjusted model, the interaction between SDEP implementation and bystander CPR was significant for SHD (p = 0.002). CONCLUSION: Adjusting for confounders, the SDEP increased SHD in patients who received bystander CPR and there was a significant interaction between SDEP and bystander CPR. Single dose epinephrine protocol and MDEP had similar SHD rates regardless of rhythm type.

4.
Am Heart J Plus ; 40: 100372, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38586432

ABSTRACT

Background: Diagnosing ischemia in emergency department (ED) patients with suspected acute coronary syndrome (sACS) is challenging with equivocal disposition of intermediate risk patients. Objective: Compare sensitivity and specificity of magnetocardiography (MCG) versus standard of care (SOC) stress testing in diagnosing myocardial ischemia. Methods: Multicenter, prospective, observational cohort study. ED patients with sACS and HEART score ≥ 3 underwent 90 s noninvasive MCG to detect myocardial ischemia. Results were blinded to the patient's clinicians. MCGs were read independently by 3 physicians blinded to clinical data. Myocardial ischemia was ≥70 % epicardial coronary artery stenosis, revascularization within 30 days, or 30-day major adverse cardiac events (MACE). Time to first test (TTT) and patient satisfaction for MCG and SOC were compared. Results: Of enrolled patients (N = 390) (mean age 59 ± 12 years, 45 % female), 99 (25 %) underwent a non-invasive stress test: 42 (14 %) diagnosed with ischemia. MCG sensitivity was 66.7 % (50.5-80.4 %, 95 % CI) and specificity 57.1 % (50.0-63.3 %, 95 % CI) for detecting coronary ischemia. Noninvasive stress testing (stress echo, nuclear stress, and exercise stress) had the same sensitivity 66.7 % (95 % CI 29.9 % to 92.5 %) and a specificity of 89.9 % (95 % CI 81.7-95.3 %). Mean TTT was shorter for MCG, 3.18 h (SD 1.91) vs. SOC stress testing 22.71 (SD 15.23), p < 0.0001. Mean patient experience was MCG 4.7 versus 3.0 SOC stress testing (p < 0.0001). Conclusion: MCG provides similar sensitivity and lower specificity as non-invasive stress testing in ED sACS patients. Time to test is shorter for MCG with higher patient satisfaction scores.

5.
J Am Coll Emerg Physicians Open ; 5(2): e13140, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38567033

ABSTRACT

Objective: Protocols to evaluate for myocardial infarction (MI) using high-sensitivity cardiac troponin (hs-cTn) have the potential to drive costs upward due to the added sensitivity. We performed an economic evaluation of an accelerated protocol (AP) to evaluate for MI using hs-cTn to identify changes in costs of treatment and length of stay compared with conventional testing. Methods: We performed a planned secondary economic analysis of a large, cluster randomized trial across nine emergency departments (EDs) from July 2020 to April 2021. Patients were included if they were 18 years or older with clinical suspicion for MI. In the AP, patients could be discharged without further testing at 0 h if they had a hs-cTnI < 4 ng/L and at 1 h if the initial value were 4 ng/L and the 1-h value ≤7 ng/L. Patients in the standard of care (SC) protocol used conventional cTn testing at 0 and 3 h. The primary outcome was the total cost of treatment, and the secondary outcome was ED length of stay. Results: Among 32,450 included patients, an AP had no significant differences in cost (+$89, CI: -$714, $893 hospital cost, +$362, CI: -$414, $1138 health system cost) or ED length of stay (+46, CI: -28, 120 min) compared with the SC protocol. In lower acuity, free-standing EDs, patients under the AP experienced shorter length of stay (-37 min, CI: -62, 12 min) and reduced health system cost (-$112, CI: -$250, $25). Conclusion: Overall, the implementation of AP using hs-cTn does not result in higher costs.

6.
J Pathol ; 263(1): 89-98, 2024 05.
Article in English | MEDLINE | ID: mdl-38433721

ABSTRACT

Brain metastases can occur in nearly half of patients with early and locally advanced (stage I-III) non-small cell lung cancer (NSCLC). There are no reliable histopathologic or molecular means to identify those who are likely to develop brain metastases. We sought to determine if deep learning (DL) could be applied to routine H&E-stained primary tumor tissue sections from stage I-III NSCLC patients to predict the development of brain metastasis. Diagnostic slides from 158 patients with stage I-III NSCLC followed for at least 5 years for the development of brain metastases (Met+, 65 patients) versus no progression (Met-, 93 patients) were subjected to whole-slide imaging. Three separate iterations were performed by first selecting 118 cases (45 Met+, 73 Met-) to train and validate the DL algorithm, while 40 separate cases (20 Met+, 20 Met-) were used as the test set. The DL algorithm results were compared to a blinded review by four expert pathologists. The DL-based algorithm was able to distinguish the eventual development of brain metastases with an accuracy of 87% (p < 0.0001) compared with an average of 57.3% by the four pathologists and appears to be particularly useful in predicting brain metastases in stage I patients. The DL algorithm appears to focus on a complex set of histologic features. DL-based algorithms using routine H&E-stained slides may identify patients who are likely to develop brain metastases from those who will remain disease free over extended (>5 year) follow-up and may thus be spared systemic therapy. © 2024 The Authors. The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.


Subject(s)
Brain Neoplasms , Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Humans , Lung Neoplasms/pathology , Carcinoma, Non-Small-Cell Lung/pathology , Algorithms , Pathologists
7.
Heart ; 110(12): 838-845, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38471727

ABSTRACT

BACKGROUND: To determine if the European Society of Cardiology 0/1-hour (ESC 0/1-h) algorithm with high-sensitivity cardiac troponin T (hs-cTnT) meets the ≥99% negative predictive value (NPV) safety threshold for 30-day cardiac death or myocardial infarction (MI) in older, middle-aged and young subgroups. METHODS: We conducted a subgroup analysis of adult emergency department patients with chest pain prospectively enrolled from eight US sites (January 2017 to September 2018). Patients were stratified into rule-out, observation and rule-in zones using the hs-cTnT ESC 0/1-h algorithm and classified as older (≥65 years), middle aged (46-64 years) or young (21-45 years). Patients had 0-hour and 1-hour hs-cTnT measures (Roche Diagnostics) and a History, ECG, Age, Risk factor and Troponin (HEART) score. Fisher's exact tests compared rule-out and 30-day cardiac death or MI rates between ages. NPVs with 95% CIs were calculated for the ESC 0/1-h algorithm with and without the HEART score. RESULTS: Of 1430 participants, 26.9% (385/1430) were older, 57.4% (821/1430) middle aged and 15.7% (224/1430) young. Cardiac death or MI at 30 days occurred in 12.8% (183/1430). ESC 0/1-h algorithm ruled out 35.6% (137/385) of older, 62.1% (510/821) of middle-aged and 79.9% of (179/224) young patients (p<0.001). NPV for 30-day cardiac death or MI was 97.1% (95% CI 92.7% to 99.2%) among older patients, 98.4% (95% CI 96.9% to 99.3%) in middle-aged patients and 99.4% (95% CI 96.9% to 100%) among young patients. Adding a HEART score increased NPV to 100% (95% CI 87.7% to 100%) for older, 99.2% (95% CI 97.2% to 99.9%) for middle-aged and 99.4% (95% CI 96.6% to 100%) for young patients. CONCLUSIONS: In older and middle-aged adults, the hs-cTnT ESC 0/1-h algorithm was unable to reach a 99% NPV for 30-day cardiac death or MI unless combined with a HEART score. TRIAL REGISTRATION NUMBER: NCT02984436.


Subject(s)
Algorithms , Biomarkers , Myocardial Infarction , Predictive Value of Tests , Troponin T , Humans , Troponin T/blood , Middle Aged , Male , Female , Adult , Age Factors , Aged , Biomarkers/blood , Myocardial Infarction/blood , Myocardial Infarction/diagnosis , Myocardial Infarction/mortality , Young Adult , Prospective Studies , Time Factors , Risk Assessment/methods , Societies, Medical , Chest Pain/blood , Chest Pain/diagnosis , Chest Pain/etiology , Emergency Service, Hospital , United States/epidemiology , Cardiology/standards , Risk Factors
8.
J Am Coll Cardiol ; 83(13): 1181-1190, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38538196

ABSTRACT

BACKGROUND: The American College of Cardiology (ACC) recently published an Expert Consensus Decision Pathway for chest pain. OBJECTIVES: The purpose of this study was to validate the ACC Pathway in a multisite U.S. METHODS: An observational cohort study of adults with possible acute coronary syndrome was conducted. Patients were accrued from 5 U.S. Emergency Departments (November 1, 2020, to July 31, 2022). ECGs and 0- and 2-hour high-sensitivity troponin (Beckman Coulter) measures were used to stratify patients according to the ACC Pathway. The primary safety outcome was 30-day all-cause death or myocardial infarction (MI). Efficacy was defined as the proportion stratified to the rule-out zone. Negative predictive value for 30-day death or MI was assessed among the whole cohort and in a subgroup of patients with coronary artery disease (CAD) (prior MI, revascularization, or ≥70% coronary stenosis). RESULTS: ACC Pathway assessments were complete in 14,395 patients, of whom 51.7% (7,437 of 14,395) were women with a median age of 56 years (Q1-Q3: 44-68 years). Known CAD was present in 23.5% (3,386 of 14,395) and 30-day death or MI occurred in 8.1% (1,168 of 14,395). The ACC Pathway had an efficacy of 48.1% (95% CI: 47.3%-49.0%). Among patients in the rule-out zone, 0.3% (22 of 6,930) had death or MI at 30 days, yielding a negative predictive value of 99.7% (95% CI: 99.5%-99.8%). In patients with known CAD, 20.0% (676 of 3,386) were classified to the rule-out zone, of whom 1.5% (10 of 676) had death or MI. CONCLUSIONS: The ACC expert consensus decision pathway was safe and efficacious. However, it may not be safe for use among patients with known CAD.


Subject(s)
Acute Coronary Syndrome , Cardiology , Myocardial Infarction , Adult , Female , Humans , Male , Middle Aged , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/complications , Chest Pain/diagnosis , Chest Pain/etiology , Consensus , Emergency Service, Hospital , Myocardial Infarction/complications , Prospective Studies , United States/epidemiology , Aged
9.
Am J Emerg Med ; 79: 111-115, 2024 May.
Article in English | MEDLINE | ID: mdl-38417221

ABSTRACT

BACKGROUND: The European Society of Cardiology (ESC) 0/1-h high sensitivity troponin T (hs-cTnT) algorithm does not differentiate risk based on known coronary artery disease (CAD: prior myocardial infarction [MI], coronary revascularization, or ≥ 70% coronary stenosis). We recently evaluated its performance among patients with known CAD at 30-days, but little is known about its longer-term risk prediction. The objective of this study is to determine and compare the performance of the algorithm at 90-days among patients with and without known CAD. METHODS: We performed a pre-planned subgroup analysis of the STOP-CP cohort, which prospectively enrolled ED patients ≥21 years old with symptoms suggestive of ACS without ST-elevation on initial ECG across 8 US sites (1/25/2017-9/6/2018). Participants with 0- and 1-h hs-cTnT measures (Roche, Basel, Switzerland) were stratified into rule-out, observe, and rule-in groups using the ESC 0/1-h algorithm. Algorithm performance was tested among patients with or without known CAD, as determined by the treating provider. The primary outcome was cardiac death or MI at 90-days. Fisher's exact tests were used to compare 90-day event and rule-out rates between patients with and without known CAD. Negative predictive values (NPVs) for 90-day cardiac death or MI with exact 95% confidence intervals were calculated and compared using Fisher's exact test. RESULTS: The STOP-CP study accrued 1430 patients, of which 31.4% (449/1430) had known CAD. Cardiac death or MI at 90 days was more common in patients with known CAD than in those without [21.2% (95/449) vs. 10.0% (98/981); p < 0.001]. Using the ESC 0/1-h algorithm, 39.6% (178/449) of patients with known CAD and 66.1% (648/981) of patients without known CAD were ruled-out (p < 0.001). Among rule-out patients, 90-day cardiac death or MI occurred in 3.4% (6/178) of patients with known CAD and 1.2% (8/648) without known CAD (p = 0.09). NPV for 90-day cardiac death or MI was 96.6% (95%CI 92.8-98.8) among patients with known CAD and 98.8% (95%CI 97.6-99.5) in patients without known CAD (p = 0.09). CONCLUSION: Patients with known CAD who were ruled-out using the ESC 0/1-h hs-cTnT algorithm had a high rate of missed 90-day cardiac events, suggesting that the ESC 0/1-h hs-cTnT algorithm may not be safe for use among patients with known CAD. TRIAL REGISTRATION: High-Sensitivity Cardiac Troponin T to Optimize Chest Pain Risk Stratification (STOP-CP; ClinicalTrials.gov: NCT02984436; https://clinicaltrials.gov/ct2/show/NCT02984436).


Subject(s)
Cardiology , Coronary Artery Disease , Humans , Young Adult , Adult , Troponin T , Coronary Artery Disease/complications , Coronary Artery Disease/diagnosis , Prospective Studies , Algorithms , Death , Biomarkers
11.
ArXiv ; 2024 Feb 09.
Article in English | MEDLINE | ID: mdl-38351942

ABSTRACT

In the realm of cerebrovascular monitoring, primary metrics typically include blood pressure, which influences cerebral blood flow (CBF) and is contingent upon vessel radius. Measuring CBF non-invasively poses a persistent challenge, primarily attributed to the difficulty of accessing and obtaining signal from the brain. This study aims to introduce a compact speckle visibility spectroscopy (SVS) device designed for non-invasive CBF measurements, offering cost-effectiveness and scalability while tracking CBF with remarkable sensitivity and temporal resolution. The wearable hardware has a modular design approach consisting solely of a laser diode as the source and a meticulously selected board camera as the detector. They both can be easily placed on a subject's head to measure CBF with no additional optical elements. The SVS device can achieve a sampling rate of 80 Hz with minimal susceptibility to external disturbances. The device also achieves better SNR compared with traditional fiber-based SVS devices, capturing about 70 times more signal and showing superior stability and reproducibility. It is designed to be paired and distributed in multiple configurations around the head, and measure signals that exceed the quality of prior optical CBF measurement techniques. Given its cost-effectiveness, scalability, and simplicity, this laser-centric tool offers significant potential in advancing non-invasive cerebral monitoring technologies.

12.
Circ Cardiovasc Qual Outcomes ; 17(3): e010270, 2024 03.
Article in English | MEDLINE | ID: mdl-38328912

ABSTRACT

BACKGROUND: The HEART Pathway (History, Electrocardiogram, Age, Risk factors, Troponin) can be used with high-sensitivity cardiac troponin to risk stratify emergency department patients with possible acute coronary syndrome. However, data on whether a high-sensitivity HEART Pathway (hs-HP) are safe and effective is lacking. METHODS: An interrupted time series study was conducted at 5 North Carolina sites in 26 126 adult emergency department patients being investigated for possible acute coronary syndrome and without ST-segment-elevation myocardial infarction. Patients were accrued into 16-month preimplementation and postimplementation cohorts with a 6-month wash-in phase. Preimplementation (January 2019 to April 2020), the traditional HEART Pathway was used with 0- and 3-hour contemporary troponin measures (Siemens). In the postimplementation period (November 2020 to February 2022), a modified hs-HP was used with 0- and 2-hour high-sensitivity cardiac troponin (Beckman Coulter) measures. The primary safety and effectiveness outcomes were 30-day all-cause death or myocardial infarction and 30-day hospitalizations. These outcomes and early discharge rate (emergency department discharge without stress testing or coronary angiography) were determined from health records and death index data. Outcomes were compared preimplementation versus postimplementation using χ2 tests and multivariable logistic regression to adjust for potential confounders. RESULTS: Preimplementation and postimplementation cohorts included 12 317 and 13 809 patients, respectively, of them 52.7% (13 767/26 126) were female with a median age of 54 years (interquartile range, 42-66). Rates of 30-day death or MI were 6.8% (945/13 809) postimplementation and 7.7% (948/12 317) preimplementation (adjusted odds ratio, 1.00 [95% CI, 0.90-1.11]). hs-HP implementation was associated with 19.9% (95% CI, 18.7%-21.1%) higher early discharges (post versus pre: 63.6% versus 43.7%; adjusted odds ratio, 2.22 [95% CI, 2.10-2.35]). The hs-HP was also associated with 16.1% (95% CI, 14.9%-17.3%) lower 30-day hospitalizations (postimplementation versus preimplementation, 31.4% versus 47.5%; adjusted odds ratio, 0.51 [95% CI, 0.48-0.54]). Among early discharge patients, death or myocardial infarction occurred in 0.5% (41/8780) postimplementation versus 0.4% (22/5383) preimplementation (P=0.61). CONCLUSIONS: hs-HP implementation is associated with increased early discharges without increasing adverse events. These findings support the use of a modified hs-HP to improve chest pain care.


Subject(s)
Acute Coronary Syndrome , Myocardial Infarction , Adult , Humans , Female , Middle Aged , Male , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/therapy , Predictive Value of Tests , Myocardial Infarction/diagnosis , Troponin , Chest Pain , Emergency Service, Hospital , Biomarkers
13.
Crit Care Explor ; 6(2): e1026, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38333076

ABSTRACT

OBJECTIVES: To assess the in vitro IntelliSep test, a microfluidic assay that quantifies the state of immune activation by evaluating the biophysical properties of leukocytes, as a rapid diagnostic for sepsis. DESIGN: Prospective cohort study. SETTING: Five emergency departments (EDs) in Louisiana, Missouri, North Carolina, and Washington. PATIENTS: Adult patients presenting to the ED with signs (two of four Systemic Inflammatory Response Syndrome criteria, where one must be temperature or WBC count) or suspicion (provider-ordered culture) of infection. INTERVENTIONS: All patients underwent testing with the IntelliSep using ethylene diamine tetraacetic acid-anticoagulated whole blood followed by retrospective adjudication for sepsis by sepsis-3 criteria by a blinded panel of physicians. MEASUREMENTS AND MAIN RESULTS: Of 599 patients enrolled, 572 patients were included in the final analysis. The result of the IntelliSep test is reported as the IntelliSep Index (ISI), ranging from 0.1 to 10.0, divided into three interpretation bands for the risk of sepsis: band 1 (low) to band 3 (high). The median turnaround time for ISI results was 7.2 minutes. The ISI resulted band 1 in 252 (44.1%), band 2 in 160 (28.0%), and band 3 in 160 (28.0%). Sepsis occurred in 26.6% (152 of 572 patients). Sepsis prevalence was 11.1% (95% CI, 7.5-15.7%) in band 1, 28.1% (95% CI, 21.3-35.8%) in band 2, and 49.4% (95% CI, 41.4-57.4%) in band 3. The Positive Percent Agreement of band 1 was 81.6% and the Negative Percent Agreement of band 3 was 80.7%, with an area under the receiver operating characteristic curve of 0.74. Compared with band 1, band 3 correlated with adverse clinical outcomes, including mortality, and resource utilization. CONCLUSIONS: Increasing ISI interpretation band is associated with increasing probability of sepsis in patients presenting to the ED with suspected infection.

14.
Prehosp Emerg Care ; : 1-8, 2024 Jan 18.
Article in English | MEDLINE | ID: mdl-38235978

ABSTRACT

BACKGROUND: The objective of this study is to identify patient and EMS agency factors associated with timely reperfusion of patients with ST-elevation myocardial infarction (STEMI). METHODS: We conducted a cohort study of adult patients (≥18 years old) with STEMI activations from 2016 to 2020. Data was obtained from a regional STEMI registry, which included eight rural county EMS agencies and three North Carolina percutaneous coronary intervention (PCI) centers. On each patient, prehospital and in-hospital time intervals were abstracted. The primary outcome was the ability to achieve the 90-minute EMS FMC to PCI time goal (yes vs. no). We used generalized estimating equations accounting for within-agency clustering to evaluate the association between patient and agency factors and meeting first medical contact (FMC) to PCI time goal while accounting for clustering within the agency. RESULTS: Among 365 rural STEMI patients 30.1% were female (110/365) with a mean age of 62.5 ± 12.7 years. PCI was performed within the time goal in 60.5% (221/365) of encounters. The FMC to PCI time goal was met in 45.5% (50/110) of women vs 69.8% (178/255) of men (p < 0.001). The median PCI center activation time was 12 min (IQR 7-19) in the group that received PCI within the time goal compared to 21 min (IQR 10-37) in the cohort that did not. After adjusting for loaded mileage and other clinical variables (e.g., pulse rate, hypertension etc.), the male sex was associated with an improved chance of meeting the goal of FMC to PCI (aOR: 2.94; 95% CI 2.11-4.10) compared to the female sex. CONCLUSION: Nearly 40% of rural STEMI patients transported by EMS failed to receive FMC to PCI within 90 min. Women were less likely than men to receive reperfusion within the time goal, which represents an important health care disparity.

15.
JAMA Netw Open ; 7(1): e2350511, 2024 Jan 02.
Article in English | MEDLINE | ID: mdl-38198141

ABSTRACT

Importance: More than 80% of patients who present to the emergency department (ED) with acute heart failure (AHF) are hospitalized. With more than 1 million annual hospitalizations for AHF in the US, safe and effective alternatives are needed. Care for AHF in short-stay units (SSUs) may be safe and more efficient than hospitalization, especially for lower-risk patients, but randomized clinical trial data are lacking. Objective: To compare the effectiveness of SSU care vs hospitalization in lower-risk patients with AHF. Design, Setting, and Participants: This multicenter randomized clinical trial randomly assigned low-risk patients with AHF 1:1 to SSU or hospital admission from the ED. Patients received follow-up at 30 and 90 days post discharge. The study began December 6, 2017, and was completed on July 22, 2021. The data were analyzed between March 27, 2020, and November 11, 2023. Intervention: Randomized post-ED disposition to less than 24 hours of SSU care vs hospitalization. Main Outcomes and Measures: The study was designed to detect at least 1-day superiority for a primary outcome of days alive and out of hospital (DAOOH) at 30-day follow-up for 534 participants, with an allowance of 10% participant attrition. Due to the COVID-19 pandemic, enrollment was truncated at 194 participants. Before unmasking, the primary outcome was changed from DAOOH to an outcome with adequate statistical power: quality of life as measured by the 12-item Kansas City Cardiomyopathy Questionnaire (KCCQ-12). The KCCQ-12 scores range from 0 to 100, with higher scores indicating better quality of life. Results: Of the 193 patients enrolled (1 was found ineligible after randomization), the mean (SD) age was 64.8 (14.8) years, 79 (40.9%) were women, and 114 (59.1%) were men. Baseline characteristics were balanced between arms. The mean (SD) KCCQ-12 summary score between the SSU and hospitalization arms at 30 days was 51.3 (25.7) vs 45.8 (23.8) points, respectively (P = .19). Participants in the SSU arm had 1.6 more DAOOH at 30-day follow-up than those in the hospitalization arm (median [IQR], 26.9 [24.4-28.8] vs 25.4 [22.0-27.7] days; P = .02). Adverse events were uncommon and similar in both arms. Conclusions and Relevance: The findings show that the SSU strategy was no different than hospitalization with regard to KCCQ-12 score, superior for more DAOOH, and safe for lower-risk patients with AHF. These findings of lower health care utilization with the SSU strategy need to be definitively tested in an adequately powered study. Trial Registration: ClinicalTrials.gov Identifier: NCT03302910.


Subject(s)
Heart Failure , Patient Discharge , Female , Humans , Male , Middle Aged , Aftercare , Emergency Service, Hospital , Heart Failure/therapy , Hospitalization , Pandemics , Quality of Life , Aged
16.
Prehosp Emerg Care ; 28(2): 335-341, 2024.
Article in English | MEDLINE | ID: mdl-37669502

ABSTRACT

BACKGROUND: Emergency medical services (EMS) clinicians demonstrate a high prevalence of chronic medical conditions that place them at risk for early mortality. Workplace health promotion programs improve health outcomes, but the availably of such programs for EMS clinicians has not been described. We investigate the availability, scope, and participation of workplace health promotion programs available to EMS clinicians in North Carolina (NC). METHODS: We administered an electronic survey based on the Centers for Disease Control and Prevention Worksite Health ScoreCard to key representatives of EMS agencies within NC that provide primarily transport-capable 9-1-1 response with ground ambulances. We collected information on agency size, rurality, elements of health promotion programs offered, incentives for participation, and participation rate. We calculated descriptive statistics using frequency and percentage for worksite and health promotion program characteristics. We compared the participation rate for agencies who did and did not incentivize participation using Fisher's exact test. RESULTS: Complete responses were received from 69 of 92 agencies (response = 75%) that collectively employ 6679 EMS clinicians [median employees per agency 71 (IQR 50-131)]. Most agencies (88.4%, 61/69) offered at least one element of a worksite health program, but only 13.0% (9/69) offered all elements of a worksite health program. In descending order, the availability of program elements were employee assistance programs (73.9%, 51/69), supportive physical and social environment (66.7%, 46/69), health education (62.3%, 43/69), health risk assessments (52.2%, 36/69), and organization culture of health promotion (20.3%, 14/69). Of agencies with programs, few (11.5%, 7/61) required participation, but most (59.0%, 36/61) offered incentives to participate. Participation rates were <25% among nearly all of the agencies that did not offer incentives, but >50% among most agencies that did offer incentives (p < 0.001). CONCLUSION: While most agencies offer at least one element of a worksite health promotion program, few agencies offer all elements and participation rates are low.


Subject(s)
Emergency Medical Services , Humans , North Carolina , Health Promotion , Health Education , Workplace
17.
Clin Cardiol ; 47(2): e24199, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38088463

ABSTRACT

The diagnostic performance of the high-sensitivity troponin T (hs-cTnT) European Society of Cardiology (ESC) 0/1-h algorithm in sex and race subgroups of US Emergency Department (ED) patients is unclear. A pre-planned subgroup analysis of the STOP-CP cohort study was conducted. Participants with 0- and 1-h hs-cTnT measures from eight US EDs (1/2017 to 9/2018) were stratified into rule-out, observation, and rule-in zones using the hs-cTnT ESC 0/1 algorithm. The primary outcome was adjudicated 30-day cardiac death or MI. The proportion with the primary outcome in each zone was compared between subgroups with Fisher's exact tests. The negative predictive value (NPV) of the ESC 0/1 rule-out zone for 30-day CDMI was calculated and compared between subgroups using Fisher's exact tests. Of the 1422 patients enrolled, 54.2% (770/1422) were male and 58.1% (826/1422) white with a mean age of 57.6 ± 12.8 years. At 30 days, cardiac death or myocardial infarction (MI) occurred in 12.9% (183/1422) of participants. Among patients stratified to the rule-out zone, 30-day cardiac death or MI occurred in 1.1% (5/436) of women versus 2.1% (8/436) of men (p = .40) and 1.2% (4/331) of non-white patients versus 1.8% (9/490) of white patients (p = .58). The NPV for 30-day cardiac death or MI was similar among women versus men (98.9% [95% confidence interval, CI: 97.3-99.6] vs. 97.9% [95% CI: 95.9-99.1]; p = .40) and among white versus non-white patients (98.8% [95% CI: 96.9-99.7] vs. 98.2% [95% CI: 96.5-99.2]; p = .39). NPVs <99% in each subgroup suggest the hs-cTnT ESC 0/1-h algorithm may not be safe for use in US EDs. Trial Registration: High-Sensitivity Cardiac Troponin T to Optimize Chest Pain Risk Stratification (STOP-CP; ClinicalTrials.gov: NCT02984436; https://clinicaltrials.gov/ct2/show/NCT02984436).


Subject(s)
Cardiology , Myocardial Infarction , Humans , Male , Female , Adult , Middle Aged , Aged , Troponin T , Cohort Studies , Race Factors , Prospective Studies , Myocardial Infarction/diagnosis , Algorithms , Death , Biomarkers
18.
Acad Emerg Med ; 31(3): 239-248, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37925594

ABSTRACT

BACKGROUND: The diagnostic performance of the high-sensitivity troponin T (hs-cTnT) 0/2-h algorithm is unclear among U.S. emergency department (ED) patients with acute chest pain. METHODS: A preplanned subgroup analysis of the STOP-CP cohort study was conducted. Participants with 0- and 2-h hs-cTnT measures prospectively enrolled at eight U.S. EDs from January 2017 to September 2018 were stratified into rule-out, observation, and rule-in zones using the hs-cTnT 0/2-h algorithm alone and combined with the history, electrocardiogram, age, and risk factor (HEAR) score. The primary outcome was adjudicated 30-day cardiac death or myocardial infarction (CDMI). The sensitivity and negative predictive value (NPV) of the 0/2-h rule-out zone and specificity and positive predictive value (PPV) of the rule-in zone for 30-day CDMI were calculated. RESULTS: Of the 1307 patients accrued, 53.6% (700/1307) were male and 58.6% (762/1307) were White, with a mean ± SD age of 57.5 ± 12.7 years. At 30 days, CDMI occurred in 12.9% (168/1307) of participants. The 0/2-h algorithm ruled out 61.4% (802/1307) of patients. Among rule-out patients, 1.9% (15/802) experienced 30-day CDMI, resulting in a sensitivity of 91.1% (95% confidence interval [CI] 85.7%-94.9%) and NPV of 98.1% (95% CI 96.9%-98.9%). The 0/2-h algorithm ruled in 12.4% (162/1307) patients of whom 61.7% (100/162) experienced 30-day CDMI. The rule-in zone specificity was 94.6% (95% CI 93.1%-95.8%) and PPV was 61.7% (95% CI 53.8%-69.2%) for 30-day CDMI. The 0/2-h algorithm combined with HEAR score ruled out 30.7% (401/1307) of patients with a sensitivity and NPV for 30-day CDMI of 98.2% (95% CI 94.9%-99.6%) and 99.3% (95% CI 97.8%-99.8%), respectively. CONCLUSIONS: The hs-cTnT 0/2-h algorithm ruled out most patients. With NPV of <99% for 30-day CDMI, the hs-cTnT 0/2-h algorithm, many emergency physicians may not consider it safe to use for U.S. ED patients. When combined with a low-risk HEAR score, NPV was >99% for 30-day CDMI at the cost of reduced efficacy.


Subject(s)
Myocardial Infarction , Troponin T , Humans , Male , Adult , Middle Aged , Aged , Female , Cohort Studies , Prospective Studies , Time Factors , Myocardial Infarction/diagnosis , Predictive Value of Tests , Algorithms , Emergency Service, Hospital , Biomarkers
20.
Clin Biochem ; 121-122: 110679, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37884085

ABSTRACT

BACKGROUND: The Atellica® VTLi point-of-care (POC) High Sensitivity Cardiac Troponin-I (hs-cTnI) assay is intended for use as an aid in the diagnosis of myocardial infarction (MI). Our primary objective is to assess its diagnostic performance in patients presenting with suspected acute coronary syndrome (ACS). METHODS: This prospective observational study will enrol ∼1500 patients at ∼20 U.S. Emergency Departments. After informed consent, adults (>21 years of age) with suspected ACS, and no prior enrollment in this study, will provide a fingerstick and venous blood sample within 2 h of ED presentation, >2 to ≤4 h, and >4 to ≤9 h (max. blood draw = 60 mL). HEART and EDACS scores will be prospectively documented. Patients without the first blood draw may be enrolled if the second draw was obtained. Capillary and venous whole blood will undergo Atellica VTLi assay testing, with remaining venous sample processed to plasma and run. All results will be blinded to the clinical care team. Site operators will undergo a 3-day familiarization period. Quality control testing will be performed daily. At 30 ± 3 days, patient mortality status, major adverse cardiac events, and rehospitalizations will be determined. A clinical endpoint adjudication committee, blinded to hs-cTnI VTLi result, will define the final diagnosis. Sensitivity, specificity, and predictive values will describe the assay performance. RESULTS: We expect study completion within 114 weeks of enrollment of the first patient. CONCLUSIONS: It is anticipated that the Atellica VTLi hs-cTnI assay validation study will define a performance equivalent to lab-based hs-cTnI, with results within ∼8 min at the point of care.


Subject(s)
Acute Coronary Syndrome , Myocardial Infarction , Adult , Humans , Point-of-Care Systems , Troponin I , Emergency Service, Hospital , Troponin T , Biomarkers
SELECTION OF CITATIONS
SEARCH DETAIL
...