Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 39
Filter
1.
Aorta (Stamford) ; 11(6): 203-206, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38531385

ABSTRACT

Seventy years ago, in 1952, Charles A. Hufnagel implanted a caged-ball prosthesis into the descending thoracic aorta, to treat a patient with aortic valve insufficiency. In 1962, 60 years ago, the first aortic homograft was implanted in a subcoronary position by Donald N. Ross and Brian G. Barratt-Boyes. Forty years ago, in 1982, the first anticalcification treatment was introduced in commercially manufactured porcine bioprostheses. All such important or even milestone events should be remembered, since they witness efforts made by those who have significantly influenced the clinical history of aortic and valvular diseases.

2.
J Card Surg ; 37(11): 3722-3728, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36116053

ABSTRACT

BACKGROUND: Mitral valve repair using expanded polytetrafluoroethylene sutures to replace mitral chordae tendineae is a well-established procedure. However, the incidence of neo-chordae failure causing recurrent mitral regurgitation is not well defined. METHODS: We have reviewed the reported cases of complications after mitral valve repair related to the use of neo-chordae. This study was mainly carried out through PubMed, Medline, and Google Chrome websites. RESULTS: We have identified a total of 26 patients presenting with rupture of polytetrafluoroethylene neo-chordae, mostly being described as isolated cases. Few other cases of recurrent mitral regurgitation with hemolysis were found, where reoperation was not caused by neo-chordal failure but most likely by technical errors. At pathological investigation the findings were substantially similar in all reported cases. The neo-chordae retained their length and pliability, became covered with host tissue and rupture was mainly related to suture size. Mild calcification was observed not interfering with chordal function; chordal infection did never occur. CONCLUSIONS: The use of artificial neo-chordae provides excellent late results with durable mitral valve repair stability. Chordal rupture may occur late postoperatively leading to reoperation because of recurrent mitral regurgitation. Despite its rarity, this potential complication should not be overlooked during follow-up of patients after mitral valve repair using artificial neo-chordae.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve Prolapse , Chordae Tendineae/pathology , Chordae Tendineae/surgery , Humans , Mitral Valve/pathology , Mitral Valve/surgery , Mitral Valve Prolapse/surgery , Polytetrafluoroethylene , Sutures
5.
Tex Heart Inst J ; 49(2)2022 03 01.
Article in English | MEDLINE | ID: mdl-35390164

ABSTRACT

Sixty years ago, 2 cardiac operations dramatically influenced the survival of patients with valvular heart disease. The replacement of an aortic valve by Dwight Harken and of a mitral valve by Albert Starr with mechanical caged-ball valves, both in 1960, was a true milestone in the history of cardiac surgery and the beginning of a long journey toward prosthetic valve replacement full of expectations, hopes, and dreams fulfilled. Caged-ball prostheses underwent numerous modifications in design and materials to improve reliability and prevent specific mechanical and thrombogenic complications. Clinical and pathologic experience gained during the past 6 decades has enabled the development of safe, durable, and minimally thrombogenic mechanical prostheses.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Diseases , Heart Valve Prosthesis , Aortic Valve , Cardiac Surgical Procedures/adverse effects , Heart Valve Diseases/surgery , Humans , Prosthesis Design , Reproducibility of Results
7.
J Card Surg ; 36(12): 4690-4698, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34519088

ABSTRACT

BACKGROUND AND AIM: Blood cysts of cardiac valves are generally seen in newborns and infants and very rarely in adults. Although in most cases they are incidental findings they may be associated to severe cardiac or systemic complications. This study analyzes incidence, presentation, and treatment of valvular blood cysts in adults. METHODS: A review of the pertinent literature through a search mainly on PubMed and Medline was performed. RESULTS: In patients ≥18 years of age, our search disclosed 54 patients with mitral blood cysts (mean age, 48 ± 18 years), 9 with a tricuspid valve cyst (mean age, 67 ± 15 years), 3 with a blood cyst on the pulmonary valve (age 31, 43, and 44 years), and 1 aortic valve cyst in a 22-year-old man. Most patients were asymptomatic while stroke, syncope, or myocardial infarction occurred in six patients with a mitral valve cyst. Blood cysts were removed surgically in 70% of patients with a mitral cyst, in 55% with a tricuspid cyst, and in all those with a pulmonary or aortic cyst. At histology, the cyst wall was composed mainly by fibrous tissue and with the inner surface lined with typical endothelium. CONCLUSIONS: Blood cysts of cardiac valves are rare in adults but may cause life-threatening complications, particularly when located on the mitral valve. For such reason, surgical removal appears advisable, with low-risk procedures. Widespread use of multimodality imaging techniques will most likely increase the number of valvular blood cysts diagnosed also in adults.


Subject(s)
Cysts , Pulmonary Valve , Adult , Aged , Aged, 80 and over , Aortic Valve , Cysts/diagnostic imaging , Cysts/epidemiology , Cysts/surgery , Humans , Infant , Infant, Newborn , Male , Middle Aged , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Tricuspid Valve , Young Adult
9.
Eur J Cardiothorac Surg ; 59(5): 1115-1122, 2021 05 08.
Article in English | MEDLINE | ID: mdl-33367649

ABSTRACT

OBJECTIVES: We evaluated the long-term results of aortic root (AR) preservation and replacement in patients operated on for acute type A aortic dissection. METHODS: Out of 302 patients discharged after repair of acute aortic dissection (1977-2019), 124 patients had an AR ≥40 mm, which was preserved in 84 (68%, group A) patients and replaced in 40 (32%, group B) patients. Group B patients were younger (mean age 57 ± 12 vs 62 ± 11 years, P = 0.07), with a mean AR of 47 vs 43 mm and ≥moderate aortic insufficiency in 65% vs 30%. Survival, causes of death and reoperations were analysed at mean follow-up of 9 ± 8 years (6 months to 40 years). RESULTS: Actuarial survival of discharged patients at 5, 10 and 15 years was 97% (0.89-0.99), 78% (0.67-0.90) and 75% (0.64-0.88) in group A, and 85% (0.71-0.95), 62% (0.44-0.78) and 57% (0.39-0.76) in group B (log-rank test P = 0.2). Nine patients in group A (7 patients for aortic insufficiency and dilatation of the root and 2 patients for pseudoaneurysm) and 1 patient of group B (pseudoaneurysm of the right coronary button) required proximal reoperation without deaths. At 5, 10 and 15 years, the cumulative incidence of proximal aortic reoperations was 5%, 9% and 25% in group A, and 0%, 3% and 3% in group B (P = 0.02). At multivariable analysis AR >45 mm [hazard ratio (HR) 6.8, P = 0.026] and age (HR 0.9, P = 0.016) were independently associated with proximal reoperation. CONCLUSIONS: AR preservation in acute type A dissection showed acceptable long-term outcomes. Nevertheless, a more aggressive approach appears a valid option, especially in patients with AR diameter >45 mm.


Subject(s)
Aortic Aneurysm , Aortic Dissection , Acute Disease , Aged , Aortic Dissection/surgery , Aorta , Aortic Aneurysm/surgery , Aortic Valve , Follow-Up Studies , Humans , Middle Aged , Reoperation , Retrospective Studies , Treatment Outcome
10.
Thorac Cardiovasc Surg ; 69(1): 83-91, 2021 01.
Article in English | MEDLINE | ID: mdl-31604358

ABSTRACT

BACKGROUND: Reconstruction of cardiac structures has been the goal of many surgeons even before the advent of open-heart procedures with cardiopulmonary bypass. Unsatisfactory results with synthetic materials has switched the attention to biological tissues, among which pericardium, either autologous or of animal origin, has been widely used as patch material. METHODS: We have reviewed the literature to assess the effective role of pericardial tissue in the correction of various acquired cardiac lesions. Particularly, special attention was given not only to established techniques but also to detect any peculiar and unusual application of pericardium. RESULTS: Autologous pericardium is frequently used as patch material particularly when limited valvular lesions must be corrected, while xenograft pericardium appears particularly useful in patients with endocarditis and extensive destruction of the intracardiac structures by infection and abscesses. Pericardium is an extremely versatile material owing to its pliability and strength; however, it tends to calcify in the long term when in contact with blood, although stability of the repair is maintained in most cases. CONCLUSIONS: Pericardium plays an important role in various cardiac and aortic pathologies. Tissues resistant to fibrosis and calcification to be used as patch material are the ideal solution for more successful cardiac reconstruction procedures and will hopefully be provided by the ongoing research.


Subject(s)
Cardiac Surgical Procedures , Heart Diseases/surgery , Pericardium/transplantation , Animals , Cardiac Surgical Procedures/adverse effects , Heart Diseases/diagnosis , Heart Diseases/physiopathology , Humans , Transplantation, Autologous , Transplantation, Heterologous , Treatment Outcome
12.
J Card Surg ; 35(11): 3217-3219, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32790016

ABSTRACT

Transcatheter mitral valve-in-valve replacement (TMVR) is a feasible alternative in high-risk patients requiring reoperation for failing mitral bioprosthesis. Such patients may present with hemodynamic instability or sudden complications, which may jeopardize the outcomes. We report a successful transapical TMVR in a patient, with severe kyphoscoliosis and on prolonged mechanical ventilation, with prophylactic extracorporeal membrane oxygenator support. This combined procedure may be helpful to reduce the complications of TMVR in critically ill subjects.


Subject(s)
Extracorporeal Membrane Oxygenation/methods , Heart Valve Prosthesis Implantation/methods , Kyphosis , Mitral Valve/surgery , Scoliosis , Aged , Critical Illness , Humans , Male , Postoperative Complications/prevention & control , Risk , Severity of Illness Index , Treatment Outcome
13.
J Card Surg ; 35(11): 3176-3178, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32743871

ABSTRACT

The third case reported in the literature of a left atrial neoplasm characterized by a very deceptive, low grade cellular component at its early stage of growth, so as to be diagnosed as a myxoma is presented. Two months after surgical excision, regrowth of the mass occurred, producing a pancreatic mass also. The new atrial mass was excised; a left atrial myxoid sarcoma and a pancreatic metastasis were diagnosed. One week later the atrial sarcoma grew again. This time surgery was contraindicated and the patient underwent chemotherapy with a satisfactory control of the sarcoma growth. The myxoid sarcoma may present with the deceptive appearance of a myxoma in their early stages. Therefore, patients who have undergone surgical removal of a myxoma should have a close follow-up to monitor unexpected malignant turnover.


Subject(s)
Heart Neoplasms/pathology , Heart Neoplasms/surgery , Myxoma/surgery , Pancreatic Neoplasms/secondary , Pancreatic Neoplasms/surgery , Sarcoma/secondary , Sarcoma/surgery , Diagnosis, Differential , Echocardiography , Heart Atria , Heart Neoplasms/diagnosis , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Myxoma/diagnosis , Myxoma/pathology , Pancreatic Neoplasms/pathology , Sarcoma/diagnosis , Sarcoma/pathology , Treatment Outcome
14.
Ann Thorac Surg ; 110(4): 1427-1433, 2020 10.
Article in English | MEDLINE | ID: mdl-32599040

ABSTRACT

This year marks the 60th anniversary of the first aortic and mitral valve replacements using mechanical artificial prosthesis. The first caged-ball devices represented a milestone in cardiac surgery and in the treatment of valvular disease. The following decades witnessed a great evolution in mechanical valve technology providing, through frustrating complications and stimulating successes, more reliable models to be safely used in the clinical setting. This review pays tribute to pioneers of this field who made currently available the most advanced models of mechanical prostheses with extended records of durability and performance, to be used as reliable alternatives to biological devices.


Subject(s)
Heart Valve Prosthesis/history , History, 20th Century , Humans
15.
J Card Surg ; 35(3): 679-682, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31886917

ABSTRACT

Mesothelial/monocytic incidental cardiac excrescence (MICE) is a rare benign finding made of mesothelial cells, histiocytes, and fibrin, usually found during heart valve surgery. The clinical relevance resides in the potential misdiagnosis as metastatic carcinoma or arterial embolism. The pathogenesis remains uncertain, with artifactual and reactive hypotheses. Here we present a case of MICE with paradigmatic clinical, imaging, and histological features in a 28-year-old woman with undifferentiated connective tissue disease without previous cardiac catheterization with possible pathogenesis, highlighting the importance of awareness of the existence of this lesion in patients with autoimmune disease.


Subject(s)
Autoimmune Diseases/complications , Cardiomyopathies/pathology , Cardiomyopathies/surgery , Connective Tissue Diseases/complications , Epithelium/pathology , Incidental Findings , Monocytes/pathology , Myocardium/pathology , Adult , Cardiac Surgical Procedures , Cardiomyopathies/etiology , Diagnosis, Differential , Female , Humans
16.
Thorac Cardiovasc Surg ; 68(2): 131-140, 2020 03.
Article in English | MEDLINE | ID: mdl-30060268

ABSTRACT

BACKGROUND: The Mitroflow pericardial bioprosthesis (MPB) has been recently associated with a high incidence of early structural failures, questioning its validity as cardiac valve substitute. We have therefore reviewed our experience with this device. MATERIALS AND METHODS: A total of 398 patients with a mean age of 75 ± 7 years (58% above the age of 75 years) had aortic valve replacement with a Mitroflow prosthesis (2005-2015). Most patients had calcific aortic stenosis (86%) and were in sinus rhythm (89%). Mean EuroSCORE II was 5.5 ± 6.2. Mean follow-up was 4 ± 2 years (range: 4 months to 10 years), which was 100% complete. RESULTS: Hospital mortality was 6.5%; at discharge, 25% of patients had a moderate patient-prosthesis mismatch and none had a severe mismatch. Cumulative incidence of structural valve deterioration in the entire series was 2% (95% confidence interval [CI]: 1-4) at 5 years and 7% (95% CI: 4-14) at 8 years. Significant factors influencing MPB durability were age ≤ 65 years (p < 0.001) and the presence of patient-prosthesis mismatch (p = 0.01). No cases of structural valve deterioration were observed in patients with the new prosthetic model incorporating an anticalcification treatment the first 4 years of follow-up. CONCLUSIONS: The Mitroflow prosthesis has shown satisfactory results in the first decade of use. Durability appears adversely influenced by patient age and patient-prosthesis mismatch. Thus, a careful valve size selection and implantation in patients >65 years of age appears to be associated with excellent valve durability in the aortic position. Whether the new anticalcification treatment will provide a more durable prosthesis must be verified at a longer follow-up.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/pathology , Aortic Valve/surgery , Bioprosthesis , Calcinosis/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Pericardium/transplantation , Age Factors , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Female , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Hospital Mortality , Humans , Male , Middle Aged , Prosthesis Design , Recovery of Function , Retrospective Studies , Risk Factors , Severity of Illness Index , Time Factors , Treatment Outcome
17.
Ann Thorac Surg ; 108(1): 304-308, 2019 07.
Article in English | MEDLINE | ID: mdl-30959018

ABSTRACT

The year 2018 marked the 50th anniversary of the first implant of a commercially manufactured stented porcine bioprosthesis. During the subsequent years considerable clinical and pathologic research was done to evaluate the overall performance of such devices and to identify the leading causes of failure. This brief review covers 5 decades, summarizing the initial hopes and the realities faced by surgeons who have believed from the start in these cardiac valve substitutes. From reported failures and long-term results a new generation of durable and reliable stented porcine bioprosthetic valves is currently available.


Subject(s)
Bioprosthesis/history , Heart Valve Prosthesis/history , Animals , Heart Valve Prosthesis Implantation/history , History, 20th Century , History, 21st Century , Humans , Prosthesis Design/history , Prosthesis Failure , Swine
18.
J Heart Valve Dis ; 27(1): 97-103, 2018 Jan.
Article in English | MEDLINE | ID: mdl-30560605

ABSTRACT

BACKGROUND: Biological prostheses are widely employed for aortic valve replacement (AVR). The study aim was to evaluate the performance of the Mosaic porcine bioprosthesis in the aortic position over two decades. METHODS: Between November 1995 and December 2016, a total of 254 patients (194 males, 60 females; mean age 74 ± 9 years) underwent AVR with a Mosaic bioprosthesis at the authors' institution. Among the patients, 14% were aged ≥80 years and 86% had pure or prevalent calcific aortic stenosis. Preoperatively, the mean NYHA functional class was 2.5 ± 1.0. RESULTS: Overall hospital mortality was 5%. A total of 107 late deaths occurred, but only 15 were valve-related (0.72 ± 0.19% per patient-year). Actuarial survival at 15 years was 34 ± 7%. Fourteen embolic episodes occurred, with no cases of bioprosthetic thrombosis; freedom from thromboemboli was 88 ± 4% at 15 years. Eight cases of endocarditis occurred, with a freedom of 95 ± 2% at 15 years. Structural valve deterioration (SVD) was observed in four patients, all of whom were successfully reoperated. Freedom from SVD was 97 ± 2% at 15 years and 96 ± 2% at 20 years. At the last follow up, 23 mm and 25 mm prostheses showed mean gradients of 17 ± 6 mmHg and 15 ± 4 mmHg, respectively. A significant reduction in left ventricular mass was noted in patients with aortic stenosis. CONCLUSIONS: The Mosaic bioprosthesis has shown excellent durability over two decades of clinical use, with a negligible incidence of valve degeneration and need for reoperation. Thus, it may be considered a valid option for AVR, especially in elderly patients.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis , Heart Valve Prosthesis , Aged , Aged, 80 and over , Animals , Aortic Valve/pathology , Aortic Valve Stenosis/pathology , Calcinosis/surgery , Female , Follow-Up Studies , Humans , Male , Prosthesis Design , Prosthesis Failure
19.
Minerva Med ; 109(1): 31-40, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28730800

ABSTRACT

Detecting coronary artery disease at a subclinical level has always been a challenging task for cardiologists. Various non-invasive echocardiographic approaches such as measurements of left ventricular hypertrophy, diastolic function, left atrial enlargement, valve sclerosis and calcification, epicardial fat thickness, and pulse wave velocity have been proposed to integrate the available risk-charts. The present review is a collection of evidence that supports the role of the above mentioned features in cardiac risk stratification, summarizing the state of the art in non-invasive echocardiographic coronary risk assessment. Each parameter is presented with its strengths and weaknesses, aiming to trace the future directions for the development of a reliable non-invasive approach.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Echocardiography , Asymptomatic Diseases , Cardiovascular Diseases/diagnostic imaging , Humans , Quality Improvement , Risk Assessment/methods , Risk Factors
20.
Aorta (Stamford) ; 5(5): 139-147, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29657952

ABSTRACT

BACKGROUND: Patients with annuloaortic ectasia may be surgically treated with modified Bentall or David I valve-sparing procedures. Here, we compared the long-term results of these procedures. METHODS: A total of 181 patients with annuloaortic ectasia underwent modified Bentall (102 patients, Group 1) or David I (79 patients, Group 2) procedures from 1994 to 2015. Mean age was 62 ± 11 years in Group 1 and 64 ± 16 years in Group 2. Group 1 patients were in poorer health, with a lower ejection fraction and higher functional class. RESULTS: Early mortality was 3% in Group 1 and 2.5% in Group 2. Patients undergoing a modified Bentall procedure had a higher incidence of thromboembolism and hemorrhage, whereas those undergoing a David I procedure had a higher incidence of endocarditis. Actuarial survival was 70 ± 6% at 15 years in Group 1 and 84 ± 7% at 10 years in Group 2. Actuarial freedom from reoperation was 97 ± 2% at 15 years in Group 1 and 84 ± 7% at 10 years in Group 2. In Group 2, freedom from procedure-related reoperations was 98 ± 2% at 10 years. At last follow-up, no cases of moderate or severe aortic regurgitation were observed. CONCLUSIONS: The modified Bentall and David I procedures showed excellent early and late results. The modified Bentall procedure with a mechanical conduit was associated with thromboembolic and hemorrhagic complications, whereas the David I procedure was associated with unexplained occurrences of endocarditis. Thus, the David I procedure appears to be safe, reproducible, and capable of achieving stable aortic valve repair and is therefore our currently preferred solution for patients with annuloaortic ectasia. However, the much shorter follow-up for David I patients limits the strength of our comparison between the two techniques.

SELECTION OF CITATIONS
SEARCH DETAIL
...