Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Z Med Phys ; 2023 Apr 22.
Article in English | MEDLINE | ID: mdl-37088675

ABSTRACT

INTRODUCTION: Image guided radiotherapy allows for particularly conformal tumour irradiation through precise patient positioning. Becoming the standard for radiotherapy, this increases imaging doses to the patient. The Halcyon 3.0 linear accelerator (Varian Medical Systems, Palo Alto, CA) requires daily imaging due to its geometry. For this reason, the accelerator is equipped with on-line kV and MV imaging. However, daily CBCT images required for irradiation apply additional radiation, which increases the dose to normal tissue and therefore can affect the patient's secondary cancer risk. In this study, actual organ doses were measured for the kV system, and a comparison of normal tissue doses for all available kV CBCT protocols was presented to demonstrate differences in imaging doses across entities and protocols. In addition, effective dose and secondary cancer risk from imaging are evaluated. MATERIAL AND METHODS: Measurements were performed with thermoluminescent dosimeters in an anthropomorphic phantom positioned according to each entity (brain, head and neck, breast, lung, pelvis). CBCT images were obtained, using all available pre-set protocols without further adjustment of the parameters. Measured doses for each position and each protocol were then compared and secondary cancer risk of relevant and specifically radiosensitive organs was calculated. RESULTS: It was found that imaging doses for protocols such as Pelvis and Head could be reduced by up to half using the corresponding Fast and Low Dose modes, respectively. On the other hand, larger field sizes or the Large mode yielded higher doses than their initial protocols. Image Gently was found to spare normal tissue best, however it is not suitable for certain entities due to low image quality or insufficient projection data. DISCUSSION: By using appropriate kV-CBCT protocols, it is possible to reduce imaging doses to a significant extent and therefore spare healthy tissue. Combined with studies of image quality, the results of this study could lead to adjustments in workflow regarding the choice of protocols used in daily routine. This could prevent unnecessary radiation exposure and reduce secondary cancer risk.

2.
Front Oncol ; 12: 892923, 2022.
Article in English | MEDLINE | ID: mdl-35965556

ABSTRACT

Background: Radiotherapy after breast-conserving therapy is a standard postoperative treatment of breast cancer, which can be carried out with a variety of irradiation techniques. The treatment planning must take into consideration detrimental effects on the neighbouring organs at risk-the lung, the heart, and the contralateral breast, which can include both short- and long-term effects represented by the normal tissue complication probability and secondary cancer risk. Patients and Methods: In this planning study, we investigate intensity-modulated (IMRT) and three-dimensional conformal (3D-CRT) radiotherapy techniques including sequential or simultaneously integrated boosts as well as interstitial multicatheter brachytherapy boost techniques of 38 patients with breast-conserving surgery retrospectively. We furthermore develop a 3D-printed breast phantom add-on to allow for catheter placement and to measure the out-of-field dose using thermoluminescent dosimeters placed inside an anthropomorphic phantom. Finally, we estimate normal tissue complication probabilities using the Lyman-Kutcher-Burman model and secondary cancer risks using the linear non-threshold model (out-of-field) and the model by Schneider et al. (in-field). Results: The results depend on the combination of primary whole-breast irradiation and boost technique. The normal tissue complication probabilities for various endpoints are of the following order: 1%-2% (symptomatic pneumonitis, ipsilateral lung), 2%-3% (symptomatic pneumonitis, whole lung), and 1%-2% (radiation pneumonitis grade ≥ 2, whole lung). The additional relative risk of ischemic heart disease ranges from +25% to +35%. In-field secondary cancer risk of the ipsilateral lung in left-sided treatment is around 50 per 10,000 person-years for 20 years after exposure at age 55. Out-of-field estimation of secondary cancer risk results in approximately 5 per 10,000 person-years each for the contralateral lung and breast. Conclusions: In general, 3D-CRT shows the best risk reduction in contrast to IMRT. Regarding the boost concepts, brachytherapy is the most effective method in order to minimise normal tissue complication probability and secondary cancer risk compared to teletherapy boost concepts. Hence, the 3D-CRT technique in combination with an interstitial multicatheter brachytherapy boost is most suitable in terms of risk avoidance for treating breast cancer with techniques including boost concepts.

3.
Phys Med ; 46: 81-88, 2018 Feb.
Article in English | MEDLINE | ID: mdl-29519414

ABSTRACT

BACKGROUND: In order to consider potential positioning errors there are different recipes for safety-margins for CTV-to-PTV expansion. The aim of this study is to simulate the effect of positioning inaccuracy with clinically realistic patient treatment plans. METHODS: For a collective of 40 prostate patients, the isocenter was shifted back appropriately to the applied table shifts after positioning verification, simulating that no positioning correction had been performed and the treatment plans were recalculated. All the treatment fractions with the appropriate isocenter-shifts were added to yield a new plan considering two scenarios:Afterwards all plans were analysed and compared with each other regarding target coverage, sparing of organs at risk (OAR) and normal tissue complication probability (NTCP). RESULTS: Dose distributions and especially DVH show a deterioration of the target-coverage caused by the positioning inaccuracy. Deviations in dose at a single point can reach values of over 10 Gy. In single cases minimum plan agreement only achieved 66% pass within 3% local dose for the realistic case. Organs at risk and NTCP analysis result in a slightly better sparing of the rectum. Measures of quality like homogeneity and conformity differ just minimally regarding the different scenarios. CONCLUSION: PTV-coverage suffers markedly by the positioning uncertainties, the shifted plans are in large parts clinically not acceptable. Surprisingly sparing of the OAR is not negatively affected by potential positioning errors for this prostate collective.


Subject(s)
Patient Positioning , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy , Radiation Dosage , Radiotherapy Setup Errors , Radiotherapy, Image-Guided/methods , Humans , Male , Organs at Risk/radiation effects , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided/adverse effects , Radiotherapy, Intensity-Modulated/adverse effects , Tomography, X-Ray Computed , Uncertainty
SELECTION OF CITATIONS
SEARCH DETAIL
...