Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 359
Filter
1.
Eur J Surg Oncol ; 50(10): 108564, 2024 Jul 23.
Article in English | MEDLINE | ID: mdl-39089184

ABSTRACT

OBJECTIVE: Interleukin-6 (IL-6) and tumor necrosis factor-α (TNF-α) are inflammatory cytokines produced in response to biological invasion or infection. Their levels are elevated in the blood and locally. We examined whether measuring IL-6 and TNF-α levels in serum or drainage fluid on postoperative day (POD) 1 could detect infectious complications after minimally invasive surgery for gastric cancer. METHODS: This cohort study included 205 consecutive patients who underwent laparoscopic or robot-assisted gastrectomy for gastric cancer between November 2020 and July 2023. We measured serum and drainage fluid IL-6 and TNF-α levels on POD 1 after gastrectomy. Receiver operating characteristic (ROC) curves were created to compare the diagnostic values of each cytokine and serum C-reactive protein levels for detecting postoperative infectious complications. RESULTS: IL-6 and TNF-α levels in the serum or drainage fluid were significantly higher in patients with an infectious complication. In addition, drainage fluid IL-6 levels were significantly different in patients with versus without intra-abdominal abscess. In the ROC curve analysis, serum and drainage fluid IL-6 had the highest AUC values for any infectious complication and intra-abdominal abscess, respectively. POD 1 serum IL-6 level above 47 pg/mL could detect any infectious complication with sensitivity of 74.1 % and specificity of 71.8 %. POD 1 drainage fluid IL-6 level above 14,750 pg/mL had 100 % sensitivity for detecting intra-abdominal abscess with specificity of 56.0 %. CONCLUSIONS: Measurement of IL-6 levels in blood and drainage fluid on POD 1 is valuable for early detection of postoperative infectious complications or intra-abdominal abscess after gastric cancer surgery.

2.
Asian J Endosc Surg ; 17(4): e13372, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39143668

ABSTRACT

We report the case of a 32-year-old man who developed a giant diaphragmatic hernia following the removal of a left ventricular assist device 4 years prior due to improved cardiac function. Chest radiography revealed an intrathoracic prolapse of the gastrointestinal tract. The patient was diagnosed with a diaphragmatic hernia and a laparoscopy-assisted repair was performed. A 12 × 8 cm hernia was found intraoperatively on the left diaphragm, and a large portion of the gastrointestinal tract had prolapsed into the thoracic cavity. We attempted to repair the ventromedial defect using mesh; however, it was found to be insufficient. Therefore, we used a left rectus abdominis myocutaneous flap to fill the defect and sutured it to the mesh. A myocutaneous flap could be a useful strategy in cases where complete closure with mesh is difficult.


Subject(s)
Device Removal , Heart-Assist Devices , Herniorrhaphy , Laparoscopy , Myocutaneous Flap , Surgical Mesh , Humans , Male , Adult , Herniorrhaphy/methods , Myocutaneous Flap/transplantation , Hernia, Diaphragmatic/surgery , Hernia, Diaphragmatic/etiology
3.
Surg Today ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39012353

ABSTRACT

PURPOSE: Suprapancreatic lymph node dissection is one of the most challenging procedures performed in the treatment of gastric cancer. This study aimed to investigate whether the pancreas-left gastric artery angle (PLA) can be used to predict the difficulty of the procedure. METHODS: This was a single-center cross-sectional study. Before gastrectomy, the patients were classified according to the size of the PLA into the small PLA (s-PLA; < 30°) and large PLA (l-PLA; ≥ 30°) groups in a surgeon-blinded manner. After gastrectomy, a surgeon evaluated suprapancreatic lymph node dissection as hard, normal, or easy to perform. RESULTS: Seventy-three patients were enrolled in the study. Surgeons evaluated lymph node dissection as hard in 43.8 and 8.7% of patients in the s-PLA and l-PLA groups, respectively (p = 0.002). The time taken for suprapancreatic lymph node dissection was also significantly longer in the s-PLA group than in the l-PLA group (p = 0.040). In patients who underwent laparoscopic gastrectomy, the time for node dissection in the s-PLA group was also significantly longer than that in the s-PLA group (p = 0.021), while there was no difference in those who underwent robotic surgery (p = 0.815). CONCLUSION: PLA is useful for predicting the degree of difficulty of suprapancreatic lymph node dissection during gastrectomy for gastric cancer.

4.
Anticancer Res ; 44(8): 3343-3348, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39060043

ABSTRACT

BACKGROUND/AIM: Most clear cell renal cell carcinomas (ccRCCs) have a dysfunctional von Hippel-Lindau tumor suppressor protein (VHL). Hypoxia-inducible factors 1 and 2 alpha (HIF1α and HIF2α) accumulate in ccRCC with dysfunctional VHL and up-regulate the vascular endothelial growth factor (VEGF) pathway and tumor angiogenesis. Recently, pimitespib (PIM), a potent ATP-competitive inhibitor of heat shock protein 90 (HSP90), was developed. PIM down-regulates the expression of HIF, a key protein in ccRCC progression, with anti-angiogenic effects. This study aimed to examine the effectiveness of PIM in ccRCC and the underlying mechanisms. MATERIALS AND METHODS: The efficacy and mechanism of PIM against ccRCCs was evaluated using ccRCC cell lines. RESULTS: PIM inhibited the VEGFR pathway by down-regulating VEGFR 2, phosphorylated VEGFR 2, and protein levels in downstream signaling pathways. The growth of ccRCC cell lines was inhibited by PIM. Furthermore, PIM inhibits HIF1α, HIF2α, and VEGF expression, suggesting that PIM may suppress angiogenesis in addition to the VEGFR pathway. CONCLUSION: PIM provides a novel approach for treating ccRCC and holds promise for future clinical strategies. Further in vivo and clinical research is required to elucidate the detailed relationship between the effects of PIM and ccRCC.


Subject(s)
Carcinoma, Renal Cell , HSP90 Heat-Shock Proteins , Kidney Neoplasms , Neovascularization, Pathologic , Signal Transduction , Humans , Carcinoma, Renal Cell/drug therapy , Carcinoma, Renal Cell/pathology , Carcinoma, Renal Cell/metabolism , Kidney Neoplasms/drug therapy , Kidney Neoplasms/pathology , Kidney Neoplasms/metabolism , Signal Transduction/drug effects , Cell Line, Tumor , HSP90 Heat-Shock Proteins/antagonists & inhibitors , HSP90 Heat-Shock Proteins/metabolism , Neovascularization, Pathologic/drug therapy , Cell Proliferation/drug effects , Angiogenesis Inhibitors/pharmacology , Vascular Endothelial Growth Factor A/metabolism , Vascular Endothelial Growth Factor A/antagonists & inhibitors , Vascular Endothelial Growth Factor Receptor-2/antagonists & inhibitors , Vascular Endothelial Growth Factor Receptor-2/metabolism , Hypoxia-Inducible Factor 1, alpha Subunit/metabolism , Hypoxia-Inducible Factor 1, alpha Subunit/antagonists & inhibitors , Basic Helix-Loop-Helix Transcription Factors/metabolism , Basic Helix-Loop-Helix Transcription Factors/antagonists & inhibitors , Gene Expression Regulation, Neoplastic/drug effects , Triazoles
5.
Dig Endosc ; 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38978152

ABSTRACT

Water pressure method (WPM) is useful for colorectal endoscopic submucosal dissection (ESD), characterized not only by underwater conditions but also by active water pressure via the waterjet function. However, the extension of the colorectum by injecting excess water and contaminating the operative field by stool and bleeding have been issues. This study aimed to evaluate the feasibility of a novel perfusion system using a continuous liquid-suction catheter attachment (CLCA) in colorectal ESD with WPM. We retrospectively reviewed cases in which the perfusion system was used in colorectal ESD with WPM between August 2022 and September 2023. We evaluated clinical characteristics, treatment outcomes, volume of injection by the waterjet function, volume of suction by the endoscope and CLCA, and concentration of floating matter in the operative field over time. Thirty-one cases were enrolled. The median lesion size was 30 (range, 15-100) mm. In all cases, en bloc resection was achieved without perforation. The median injection volume was 2312 (range, 1234-13,866) g. The median suction volumes by the endoscope and CLCA were 918 (range, 141-3162) and 1147 (range, 254-11,222) g, respectively. The median concentration of floating matter in the operative field (measured in 15 cases) was 15.3 (range, 7.3-112) mg/mL when the endoscope arrived at the lesion and 8.0 (range, 3.2-16) mg/mL after endoscopically washing at the beginning of the ESD. It ranged from 7.6 to 13.4 mg/dL every 20 min during ESD. This perfusion system could prevent the extension of the lumen and maintain a good field of view in colorectal ESD with WPM.

7.
Minim Invasive Ther Allied Technol ; 33(4): 245-251, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38592474

ABSTRACT

BACKGROUND: Cell-derived sheets are of global interest for regenerative therapy. Transplanting a sheet for abdominal organs requires a device for laparoscopic delivery to minimize invasiveness. Here, using a porcine model, we aimed to confirm the feasibility of a device developed to deliver sheets to the thoracic cavity in a laparoscopic transplantation procedure. MATERIAL AND METHODS: We used the device to transplant human skeletal myoblast cell sheets onto the liver and measured extra-corporeal, intra-abdominal, and total procedure times for sheet transplantation. Tissues, including the liver and the sheet, were collected two days after transplantation and analyzed histologically. RESULTS: In all experiments (n = 27), all sheets were successfully placed at target locations. The mean (± standard deviation) extra-corporeal, intra-abdominal, and total procedure times were 44 ± 29, 33 ± 12, and 77 ± 36 s, respectively. We found no difference between the two surgeons in procedure times. Histological analyses showed no liver damage with the transplantation and that sheets were transplanted closely onto the liver tissue without gaps. CONCLUSION: We confirmed the feasibility of a simple universal device to transplant cell-derived sheets via laparoscopic surgery. This device could support a minimally invasive procedure for sheet transplantation.


Subject(s)
Laparoscopy , Liver , Animals , Laparoscopy/methods , Swine , Liver/surgery , Humans , Feasibility Studies , Myoblasts, Skeletal/transplantation , Models, Animal , Operative Time , Cell Transplantation/methods , Cell Transplantation/instrumentation
8.
World J Surg ; 48(6): 1292-1296, 2024 06.
Article in English | MEDLINE | ID: mdl-38658174

ABSTRACT

In laparoscopic and thoracoscopic surgery, maintaining clear visualization is crucial for safe and efficient operation. We have developed a new scope warmer/cleaner (Lapahot®) based on "hot-pack" technology. We used our device in 20 consecutive laparoscopic and thoracoscopic cases and compared it with the conventional warm saline method. Lens fogging was not observed in any of the cases, and the cleaning function was comparable to the warm saline method. Moreover, continuous temperature monitoring showed that Lapahot® maintained its temperature much longer than warm saline. Our novel device has the potential to become the new standard for lens defogging and cleaning.


Subject(s)
Laparoscopy , Thoracoscopy , Humans , Laparoscopy/methods , Laparoscopy/instrumentation , Thoracoscopy/methods , Equipment Design , Female , Male , Middle Aged , Treatment Outcome , Aged , Adult
9.
Article in English | MEDLINE | ID: mdl-38605997

ABSTRACT

Objectives: Flexible endoscopy does not have a system that can automatically evacuate surgical smoke generated in the gastrointestinal lumen. We aimed to investigate the feasibility and potential usefulness of automatic smoke evacuation systems in flexible endoscopy. Methods: [Bench] After surgical smoke generated in the stomach was evacuated by the evacuator, the degree of residual smoke and gastric luminal collapse were evaluated to optimize the evacuator settings. [Animal] Insufflation, suction, and total operation time to complete the protocol of 10 cauterizations of the gastric mucosa were measured in three groups: "manual suction only," "manual suction with automatic evacuation (50% force)," and "manual suction with automatic evacuation (70% force)." The stability of endoscopic visualization and operability was evaluated by 10 endoscopists blinded to those suction settings, and the number of manual suctions, insufflations, and total operation time were measured. Results: [Bench] The degree of residual smoke and gastric luminal collapse were inversely correlated. [Animal] When the automatic evacuator was partially used, there was no difference in the insufflation time, but the suction time (vs 50%; p = 0.011, vs. 70%; p = 0.011) and total operation time (vs. 50%; p = 0.012, vs. 70%; p = 0.036) were significantly reduced compared to manual operation only. Furthermore, manual suction with automatic evacuation (50% force) significantly improved the stability of endoscopic visualization and operability compared to manual operation only (p = 0.041, p = 0.0085). Conclusions: The automatic smoke evacuation in flexible gastrointestinal endoscopy was potentially feasible and useful by improving the device setting.

10.
Surg Today ; 54(9): 1051-1057, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38514475

ABSTRACT

PURPOSE: As Japanese society ages, the number of surgeries performed in elderly patients with hiatal hernia (HH) is increasing. In this study, we examined the feasibility, safety, and potential effectiveness of the addition of anterior gastropexy to hiatoplasty with or without mesh repair and/or fundoplication in elderly Japanese HH patients. METHODS: We retrospectively evaluated 39 patients who underwent laparoscopic HH repair between 2010 and 2021. We divided them into 2 groups according to age: the "younger" group (< 75 years old, n = 21), and the "older" group (≥ 75 years old, n = 18). The patient characteristics, intraoperative data, and postoperative results were collected. RESULTS: The median ages were 68 and 82 years old in the younger and older groups, respectively, and the female ratio was similar between the groups (younger vs. older: 67% vs. 78%, p = 0.44). The older group had more type III/IV HH cases than the younger group (19% vs. 83%, p < 0.001). The operation time was longer in the older group than in the younger group, but there was no significant difference in blood loss, perioperative complications, or postoperative length of stay between the groups. The older group had significantly more cases of anterior gastropexy (0% vs. 78%, p < 0.001) and less fundoplication (100% vs. 67%, p = 0.004) than the younger group. There was no significant difference in HH recurrence between the groups (5% vs. 11%, p = 0.46). CONCLUSIONS: The addition of anterior gastropexy to other procedures is feasible, safe, and potentially effective in elderly Japanese patients with HH.


Subject(s)
Feasibility Studies , Fundoplication , Gastropexy , Hernia, Hiatal , Laparoscopy , Humans , Hernia, Hiatal/surgery , Aged , Aged, 80 and over , Female , Male , Retrospective Studies , Age Factors , Treatment Outcome , Gastropexy/methods , Laparoscopy/methods , Fundoplication/methods , Herniorrhaphy/methods , Operative Time , Asian People , Middle Aged , Japan , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Safety , East Asian People
11.
Int J Biol Macromol ; 265(Pt 2): 131060, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38521317

ABSTRACT

Various types of hemostatic agents are used to manage bleeding in surgery. Many such agents are animal products, which carry the risk of secondary infection. The aim of this study is to develop a novel hemostatic agent from a non-animal source that quickly stops bleeding, is easy to use, and has no risk of infection. In this study, we synthesized calcium ion-crosslinked sodium alginate (Alg-Na/Ca) by partial substitution of Ca ions for Na ions in sodium alginate. We prepared 12 kinds of Alg-Na/Ca powders with different Ca mass ratios, molecular weights, M/G ratios and particle size distributions and measured their swelling ratio and the burst pressure generated. We found that Alg-Na/Ca began to swell immediately after contact with saline, especially Alg-Na/Ca at Ca mass ratios of 74.1-77.0 % showed a high swelling ratio after 2 min and a high burst pressure, over 200 % and 500 mmHg respectively. Also, there is a correlation between the swelling ratio after 2 min and the burst pressure. Our results suggest that, by optimizing the composition conditions, Alg-Na/Ca may be an effective hemostatic agent that could act as a tamponade by absorbing and swelling at a bleeding site to quickly achieve primary hemostasis.


Subject(s)
Hemostatics , Animals , Hemostatics/pharmacology , Calcium , Hemostasis , Alginates , Ions
12.
World J Surg ; 48(4): 914-923, 2024 04.
Article in English | MEDLINE | ID: mdl-38319155

ABSTRACT

BACKGROUND: Multidisciplinary treatment combining chemotherapy, chemo radiation therapy (CRT), and surgery has been utilized for advanced esophageal cancer. However, preoperative treatment could cause postoperative inflammation and complications. We hypothesized that fibrosis surrounding tumor tissue caused by preoperative treatment could induce postoperative systemic inflammation and influence postoperative complications. METHODS: Surgical specimens from patients with thoracic esophageal cancer who underwent preoperative CRT (38 cases) or chemotherapy (77 cases) and those who received no preoperative treatment (49 cases) were evaluated to measure the fibrotic area adjacent to the tumor (10 mm from the tumor edge) by applying Azan staining. Pleural effusion and peripheral blood serum interleukin-6 levels were analyzed to evaluate local and systemic postoperative inflammation in 37 patients. RESULTS: The fibrotic areas around the tumors were significantly larger in patients who underwent preoperative CRT than in patients who underwent chemotherapy (p < 0.001) or who had received no preoperative therapy (p < 0.001). Infectious complications were higher in patients who underwent preoperative CRT than chemotherapy (p = 0.047) or surgery alone (p < 0.001). The patients with larger fibrotic areas had more infectious complications (p = 0.028). Multivariate analysis showed that both a large fibrotic area and preoperative CRT were correlated with infectious complications, but not significantly. Pleural effusion interleukin-6 was significantly higher in patients who underwent preoperative CRT than in patients who received no preoperative therapy (p = 0.013). CONCLUSIONS: A large fibrotic peritumoral esophageal tissue area after preoperative treatment could cause postoperative inflammatory response and infectious complications.


Subject(s)
Esophageal Neoplasms , Pleural Effusion , Humans , Interleukin-6/therapeutic use , Esophageal Neoplasms/surgery , Esophageal Neoplasms/pathology , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Inflammation , Retrospective Studies , Treatment Outcome
13.
Minim Invasive Ther Allied Technol ; 33(4): 200-206, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38369855

ABSTRACT

INTRODUCTION: Surgical site infection (SSI) poses a substantial postoperative challenge, affecting patient recovery and healthcare costs. While surgical wound irrigation is pivotal in SSI reduction, consensus on the optimal method remains elusive. We developed a novel device for surgical wound irrigation and conducted preclinical and clinical evaluations to evaluate its efficacy and safety. METHODS: Two preclinical experiments using swine were performed. In the washability test, two contaminated wound model were established, and the cleansing rate between the device and the conventional method were compared. In the contamination test, the irrigation procedure with a fluorescent solution assessed the surrounding contamination of drapes. Subsequently, a clinical trial involving patients undergoing abdominal surgery was conducted. RESULTS: The washability test demonstrated significantly higher cleansing rates with the device method (86.4% and 82.5%) compared to the conventional method (65.2% and 65.1%) in two contamination models. The contamination test revealed a smaller contaminated region with the device method than the conventional method. In the clinical trial involving 17 abdominal surgery cases, no superficial SSIs or adverse events related to device use were observed. CONCLUSIONS: Our newly developed device exhibits potential for achieving more effective and safe SSI control compared to conventional wound irrigation.


Subject(s)
Surgical Wound Infection , Therapeutic Irrigation , Therapeutic Irrigation/instrumentation , Therapeutic Irrigation/methods , Swine , Pilot Projects , Surgical Wound Infection/prevention & control , Humans , Animals , Female , Male , Middle Aged , Aged , Surgical Wound/therapy , Adult , Abdomen/surgery
14.
Surg Today ; 54(5): 442-451, 2024 May.
Article in English | MEDLINE | ID: mdl-37903923

ABSTRACT

PURPOSE: To investigate the indications for neoadjuvant chemotherapy (NAC) in esophageal cancer patients aged 75 years or older. METHODS: We analyzed data, retrospectively, from 155 patients over 75 years old, who underwent esophagectomy for esophageal cancer between 2010 and 2020. Forty-one patients underwent upfront surgery (US group) and 114 were treated with NAC followed by surgery (NAC group). We compared the patient backgrounds and perioperative outcomes including prognosis, between the two groups. RESULTS: The NAC group patients were significantly younger and had significantly more advanced clinical stage disease than the US group patients. The incidence of postoperative complications was similar in the two groups. Patients with a good pathological response to NAC had a significantly better prognosis than those with a poor response and those in the US group. Among patients with a performance status (PS) of 0, the 5-year OS rate was 56.5% in the NAC group and 38.1% in the US group (HR = 0.63, 95% CI 0.35-1.12). Among those with a PS of 1-2, the 5-year OS rates were 28.1% and 57.1%, respectively (HR = 1.69, 95% CI 0.99-2.89; P = 0.037 for interaction). CONCLUSIONS: NAC did not improve the postoperative prognosis of older esophageal cancer patients with a PS of 1 or higher.


Subject(s)
Esophageal Neoplasms , Neoadjuvant Therapy , Humans , Aged , Esophagectomy/adverse effects , Retrospective Studies , Esophageal Neoplasms/surgery , Prognosis
15.
Am Surg ; 90(3): 386-392, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37688476

ABSTRACT

BACKGROUND: In the short term, pylorus-preserving gastrectomy (PPG) has been reported to have advantages over distal gastrectomy (DG) with regard to postprandial symptoms and dumping syndrome. We aimed to evaluate the quality of life after PPG for early gastric cancer in the long term in comparison to that after DG. METHODS: Twenty-six patients who underwent gastrectomy (11 PPG, 15 DG) for early gastric cancer at Osaka University Hospital participated and were followed for more than 4 years. Body weight changes, nutritional status, dual-phase scintigraphy findings, endoscopic survey results, and questionnaire responses after gastrectomy were examined. RESULTS: There were significantly lower ratios of weight changes in PPG than in DG, 5 years after surgery. There were no differences in the clinicopathological characteristics, nutritional parameters, questionnaire responses, and endoscopic findings between the two groups. Based on gastric scintigraphy, although the gastric emptying of liquids showed similar curves in the two groups, gastric emptying of solids was significantly slower in the PPG group than in the DG group (P = .039). DISCUSSION: PPG had advantages with regard to long-term outcomes over DG in terms of weight maintenance and the prevention of rapid gastric emptying. PPG might be efficient in patients with early gastric cancer.


Subject(s)
Pylorus , Stomach Neoplasms , Humans , Pylorus/surgery , Stomach Neoplasms/surgery , Stomach Neoplasms/pathology , Quality of Life , Gastrectomy/methods , Gastric Emptying/physiology
16.
Minim Invasive Ther Allied Technol ; 33(2): 64-70, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38044882

ABSTRACT

BACKGROUND: Fogging and staining of a laparoscope lens negatively impact surgical visualization. We hypothesized that the disposable hot pack could not only warm but also clean laparoscopes. Hence, this study verified and developed the disposable hot pack with anti-fogging and cleaning function. MATERIAL AND METHODS: The laparoscope was inserted into a swine abdominal cavity for five minutes. Then, the laparoscopic tip was heated with 65 °C saline or the folded disposable hot pack with nonwoven fabric coated surfactant for ten seconds (n = 15). Also, a laparoscopic tip with dirt was wiped with the prototype or conventional gauze for 10 s (n = 10). The dirt, fogging, and temperature of the laparoscopic tip were respectively evaluated after the laparoscope was inserted into the abdominal cavity. RESULTS: The laparoscopic tip temperature five minutes after insertion into the abdominal cavity was similar (31.1 °C vs 31.2 °C, p = 0.748) and there was no fogging in both methods. The conventional gauze had significantly less temperature of the laparoscopic tip after cleaning and higher fogging occurrence than the prototype (29.5 °C vs 34.0 °C, p < 0.001, 30% vs 0%, p = 0.030, respectively), although there was no dirt left after both methods. CONCLUSION: The disposable hot pack has a strong potential as an anti-fogging and cleaning device for use during laparoscopic surgery.


Subject(s)
Laparoscopy , Lenses , Animals , Swine , Laparoscopy/methods , Laparoscopes , Temperature , Hot Temperature
17.
Surg Endosc ; 38(2): 488-498, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38148401

ABSTRACT

BACKGROUND: Minimally invasive total gastrectomy (MITG) is a mainstay for curative treatment of patients with gastric cancer. To define and standardize optimal surgical techniques and further improve clinical outcomes through the enhanced MITG surgical quality, there must be consensus on the key technical steps of lymphadenectomy and anastomosis creation, which is currently lacking. This study aimed to determine an expert consensus from an international panel regarding the technical aspects of the performance of MITG for oncological indications using the Delphi method. METHODS: A 100-point scoping survey was created based on the deconstruction of MITG into its key technical steps through local and international expert opinion and literature evidence. An international expert panel comprising upper gastrointestinal and general surgeons participated in multiple rounds of a Delphi consensus. The panelists voted on the issues concerning importance, difficulty, or agreement using an online questionnaire. A priori consensus standard was set at > 80% for agreement to a statement. Internal consistency and reliability were evaluated using Cronbach's α. RESULTS: Thirty expert upper gastrointestinal and general surgeons participated in three online Delphi rounds, generating a final consensus of 41 statements regarding MITG for gastric cancer. The consensus was gained from 22, 12, and 7 questions from Delphi rounds 1, 2, and 3, which were rephrased into the 41 statetments respectively. For lymphadenectomy and aspects of anastomosis creation, Cronbach's α for round 1 was 0.896 and 0.886, and for round 2 was 0.848 and 0.779, regarding difficulty or importance. CONCLUSIONS: The Delphi consensus defined 41 steps as crucial for performing a high-quality MITG for oncological indications based on the standards of an international panel. The results of this consensus provide a platform for creating and validating surgical quality assessment tools designed to improve clinical outcomes and standardize surgical quality in MITG.


Subject(s)
Stomach Neoplasms , Humans , Delphi Technique , Consensus , Stomach Neoplasms/surgery , Reproducibility of Results , Lymph Node Excision , Anastomosis, Surgical , Gastrectomy
18.
Surg Case Rep ; 9(1): 212, 2023 Dec 11.
Article in English | MEDLINE | ID: mdl-38072842

ABSTRACT

BACKGROUND: A diaphragmatic hernia is a prolapse of the abdominal organs into the thoracic cavity through a hole in the diaphragm. Traumatic diaphragmatic injuries are rare and usually occur after blunt or penetrating thoracic or abdominal traumas. Blunt diaphragmatic rupture rarely accounts for immediate mortality and may go clinically silent until complications occur which can be life threatening. It usually present late with intrathoracic herniation of abdominal viscera and carry a high mortality rate. We experienced a very rare case who showed repeated colon incarcerations 7 years after injury. And, we operated laparoscopically. CASE PRESENTATION: A 64-year-old man presented with multiple left rib fractures that occurred during an accident. After 7 years, he visited the emergency department with the chief complaint of left shoulder pain and epicardial pain after eating. He was diagnosed with transverse colon incarceration due to a left diaphragmatic hernia by computed tomography (CT) and X-ray imaging. Surgical repair was recommended, but he refused as the symptoms improved. Fourteen months later, the patient revisited the hospital in similar symptoms and improved spontaneously. He consulted our hospital for the surgical indication. We recommended that he undergo surgery, showing images of the X-ray and CT when his transverse colon was obstructed and he felt pain and when symptoms improved. Finally, he decided to undergo surgery. We performed diaphragmatic hernia repair with laparoscopic direct suturing in good view. The patient experienced an uneventful postoperative recovery period. The absence of diaphragmatic herniation recurrence was confirmed seven months after surgery. CONCLUSIONS: We experienced a traumatic diaphragmatic hernia with repeated colon incarcerations 7 years after injury and performed surgical repair laparoscopically.

19.
Surg Case Rep ; 9(1): 204, 2023 Nov 24.
Article in English | MEDLINE | ID: mdl-37999864

ABSTRACT

BACKGROUND: Severe scoliosis can cause reflux esophagitis, and is a risk factor for Barrett's adenocarcinoma of the esophagus. Severe scoliosis is associated with respiratory dysfunction, impaired operative tolerance, and anatomical difficulty in surgical manipulation, and is, therefore, considered a high surgical risk. In this report, we describe the case of a young patient with Barrett's esophageal adenocarcinoma with severe scoliosis who underwent salvage surgery after radical chemoradiotherapy. CASE PRESENTATION: The patient was a 39-year-old male. Although he had severe scoliosis and paraplegia of both lower limbs since childhood, he was independent in activities of daily living. His previous doctor, who diagnosed the esophageal cancer, determined that surgery was not indicated due to the coexistence of severe scoliosis, so he underwent chemoradiotherapy with curative intent. After chemoradiotherapy, the patient was referred to our hospital for a second opinion because of a tumor remnant. After various additional examinations, thoracoscopic and laparoscopic subtotal esophagectomy for esophageal cancer was performed, along with ante-thoracic route reconstruction using a narrow gastric tube. Although the patient had symptoms associated with postoperative reflux, he recovered well overall and was discharged home about 4 weeks after surgery. CONCLUSIONS: We report the case of an esophageal cancer patient with severe scoliosis at high surgical risk who underwent successful minimally invasive esophagectomy.

20.
Endosc Int Open ; 11(8): E714-E718, 2023 Aug.
Article in English | MEDLINE | ID: mdl-38033744

ABSTRACT

Endoscopic submucosal dissection enables en bloc resection of large superficial colorectal neoplasms. However, it is sometimes challenging to retrieve a large resected specimen via the anus without sample fragmentation. A novel "bag-type" retrieval device has been developed to accomplish complete isolation and non-destructive delivery of oversized specimens. This single-center retrospective study was performed to demonstrate the efficacy of this device for large colorectal resected specimens. Among 17 patients, we identified 18 superficial colorectal lesions for which the use of a novel retrieval device (Endo Carry Large Type) was indicated at specimen delivery at a referral cancer institute from March 2021 to July 2022. The median (interquartile range) tumor size was 62.5 (52.0-79.5) mm. Retrieval of 17 (94%) of 18 resected specimens was performed using the Endo Carry Large Type, and 16 (89%) were successfully retrieved without sample fragmentation. The median (interquartile range) retrieval time was 4 (4-8) minutes, and no apparent adverse events were observed. The novel Endo Carry Large Type device can accomplish colorectal specimen retrieval safely and quickly without specimen damage and therefore may contribute to accurate pathological diagnosis.

SELECTION OF CITATIONS
SEARCH DETAIL