ABSTRACT
Auto-transplantation has been suggested to be a favourable treatment option in comparison to prosthodontic replacements. Studies have shown an average survival rate of 89.1% for auto-transplanted teeth. This article aims to report a successful third molar auto-transplantation, despite delayed endodontic treatment because of movement control order (MCO) imposition following COVID-19 out-break in Malaysia. A 22-year-old female patient's impacted lower left third molar (38) was used as a donor to replace her lower left second molar (37), which was deemed non-restorable due to caries and root resorption as a result of impinging pressure from the impacted adjacent third molar. Successful outcome and uneventful healing were achieved over a period of one year, despite delayed endodontic treatment following auto-transplantation. A favourable auto-transplant can be achieved despite delayed endodontic treatment post-transplantation, if the procedure is performed in a good aseptic environment and bacterial load is controlled at the site (AU)
O autotransplante tem sido sugerido como uma opção de tratamento favorável em comparação com as substituições protéticas. Estudos mostraram uma taxa de sobrevivência média de 89,1% para dentes autotransplantados. Este artigo tem como objetivo relatar um autotransplante de terceiro molar bem-sucedido, apesar do atraso no tratamento endodôntico devido à imposição da ordem de controle de movimento (MCO) após o surto de COVID-19 na Malásia. O terceiro molar inferior esquerdo impactado de uma paciente de 22 anos (38) foi usado como doador para substituir seu segundo molar inferior esquerdo (37), que foi considerado não restaurável devido à cárie e reabsorção radicular como resultado da pressão de impacto do terceiro molar adjacente impactado. Resultado bem sucedido e cicatrização sem intercorrências foram alcançados ao longo de um período de um ano, apesar do atraso no tratamento endodôntico após o autotransplante. Um autotransplante favorável pode ser alcançado apesar do atraso no tratamento endodôntico pós-transplante, se o procedimento for realizado em um ambiente asséptico e com carga bacteriana controlada no local.(AU)
Subject(s)
Humans , Female , Adult , Controlled Confinement , Dental Pulp , Dental Pulp Cavity , Endodontics , COVID-19 , Molar, ThirdABSTRACT
Objective: To compare the color stability and translucency of aged and unaged experimental zirconia reinforced rice husk nanohybrid composite resin (Zr-Hybrid) with a commercialized nanofilled and a microhybrid composite resin after immersion in four different infusion media. Material and Methods: Three groups of standardized disc-shaped composite resin with 80 samples per group were prepared as follow: Group 1 (Filtek-Z350-XT), Group 2 (Zmack-Comp), and Group 3 (Zr-Hybrid). Each group was further subdivided into aged (n=40) and unaged (n=40) groups. Initial color measurements were taken using a digital spectrophotometer based on CIE L*a*b* color system. Samples in aged subgroup were subjected to 2500 thermal cycles. Subsequently, all samples were immersed in four different types of infusion media (n=10): T1 - Distilled water, T2 - Soft drink, T3 - Tea and T4 - Coffee. After 15 days, color measurements of all samples were measured again. Data were analyzed using two-way ANOVA followed by Bonferroni and paired sample t-tests with a significance level set at P=0.05. Results: Unaged Zr-Hybrid showed comparable color change to Zmack-Comp and Filtek-Z350-XT (P=0.181), but aged Zr-Hybrid demonstrated the lowest color change (P<0.001). Zr-Hybrid exhibited the lowest translucency value (P<0.001), but no significant color and translucency changes (P=0.051 and P=0.069, respectively) were observed between unaged and aged Zr-Hybrid. Soft drink had the greatest effect (P<0.001) on color change, while coffee showed the greatest effect (P<0.001) on translucency. Conclusion: Although Zr-Hybrid showed greater opacity, it still retained its color stability and translucency after accelerated aging compared to commercialized microhybrid and nanofilled composite resins. All infusion media caused discoloration and affected the composite resins' translucency. (AU)
Objetivo: Comparar a estabilidade de cor e translucidez de uma resina composta nanohíbrida de casca de arroz reforçada com zircônia experimental envelhecida e não envelhecida (Zr-Hybrid) com uma resina composta comercial nanoparticulada e microhíbrida após a imersão em quatro meios de infusão diferentes. Material e Métodos: Três grupos de resina composta em forma de disco padronizado com 80 amostras por grupo foram preparados da seguinte forma: Grupo 1 (Filtek-Z350-XT), Grupo 2 (Zmack-Comp) e Grupo 3 (Zr-Hybrid). Cada grupo foi subdividido em grupos de envelhecimento (n = 40) e não envelhecimento (n = 40). As medições iniciais de cor foram feitas usando um espectrofotômetro digital baseado no sistema de cores CIE L * a * b *. As amostras do subgrupo envelhecido foram submetidas a 2500 ciclos térmicos. Posteriormente, todas as amostras foram imersas em quatro tipos diferentes de meios de infusão (n = 10): T1 - Água destilada, T2 - Refrigerante,T3 - Chá e T4 - Café. Após 15 dias, as medições de cor de todas as amostras foram medidas novamente. Os dados foram analisados usando ANOVA dois fatores seguido por Bonferroni e testes t pareados com nível de significância estabelecido em P = 0,05. Resultados: O grupo Zr-Hybrid não envelhecido mostrou uma mudança de cor comparável a Zmack-Comp e Filtek-Z350-XT (P = 0,181), mas o grupo Zr-Hybrid envelhecido demonstrou a menor mudança de cor (P <0,001). Zr-Hybrid exibiu o menor valor de translucidez (P <0,001), mas nenhuma mudança significativa de cor e translucidez (P = 0,051 e P = 0,069, respectivamente) foram observadas entre Zr-Hybrid não envelhecido e envelhecido. O refrigerante teve o maior efeito (P <0,001) na mudança de cor, enquanto o café apresentou o maior efeito (P <0,001) na translucidez. Conclusão: Apesar do grupo Zr-Hybrid tenha mostrado maior opacidade, ele ainda manteve sua estabilidade de cor e translucidez após envelhecimento acelerado em comparação com resinas compostas micro-híbridas e nanoparticuladas comercializadas. Todos os meios de infusão causaram descoloração e afetaram a translucidez das resinas compostas (AU)