1.
Eur Radiol Exp ; 7(1): 69, 2023 11 07.
Article in English | MEDLINE | ID: mdl-37934382

ABSTRACT

BACKGROUND: Breast cancer screening through mammography is crucial for early detection, yet the demand for mammography services surpasses the capacity of radiologists. Artificial intelligence (AI) can assist in evaluating microcalcifications on mammography. We developed and tested an AI model for localizing and characterizing microcalcifications. METHODS: Three expert radiologists annotated a dataset of mammograms using histology-based ground truth. The dataset was partitioned for training, validation, and testing. Three neural networks (AlexNet, ResNet18, and ResNet34) were trained and evaluated using specific metrics including receiver operating characteristics area under the curve (AUC), sensitivity, and specificity. The reported metrics were computed on the test set (10% of the whole dataset). RESULTS: The dataset included 1,000 patients aged 21-73 years and 1,986 mammograms (180 density A, 220 density B, 380 density C, and 220 density D), with 389 malignant and 611 benign groups of microcalcifications. AlexNet achieved the best performance with 0.98 sensitivity, 0.89 specificity of, and 0.98 AUC for microcalcifications detection and 0.85 sensitivity, 0.89 specificity, and 0.94 AUC of for microcalcifications classification. For microcalcifications detection, ResNet18 and ResNet34 achieved 0.96 and 0.97 sensitivity, 0.91 and 0.90 specificity and 0.98 and 0.98 AUC, retrospectively. For microcalcifications classification, ResNet18 and ResNet34 exhibited 0.75 and 0.84 sensitivity, 0.85 and 0.84 specificity, and 0.88 and 0.92 AUC, respectively. CONCLUSIONS: The developed AI models accurately detect and characterize microcalcifications on mammography. RELEVANCE STATEMENT: AI-based systems have the potential to assist radiologists in interpreting microcalcifications on mammograms. The study highlights the importance of developing reliable deep learning models possibly applied to breast cancer screening. KEY POINTS: • A novel AI tool was developed and tested to aid radiologists in the interpretation of mammography by accurately detecting and characterizing microcalcifications. • Three neural networks (AlexNet, ResNet18, and ResNet34) were trained, validated, and tested using an annotated dataset of 1,000 patients and 1,986 mammograms. • The AI tool demonstrated high accuracy in detecting/localizing and characterizing microcalcifications on mammography, highlighting the potential of AI-based systems to assist radiologists in the interpretation of mammograms.


Subject(s)
Breast Neoplasms , Calcinosis , Deep Learning , Humans , Female , Artificial Intelligence , Retrospective Studies , Mammography
2.
Medicina (Kaunas) ; 59(9)2023 Sep 17.
Article in English | MEDLINE | ID: mdl-37763797

ABSTRACT

Standardized radiological reports stimulate debate in the medical imaging field. This review paper explores the advantages and challenges of standardized reporting. Standardized reporting can offer improved clarity and efficiency of communication among radiologists and the multidisciplinary team. However, challenges include limited flexibility, initially increased time and effort, and potential user experience issues. The efforts toward standardization are examined, encompassing the establishment of reporting templates, use of common imaging lexicons, and integration of clinical decision support tools. Recent technological advancements, including multimedia-enhanced reporting and AI-driven solutions, are discussed for their potential to improve the standardization process. Organizations such as the ACR, ESUR, RSNA, and ESR have developed standardized reporting systems, templates, and platforms to promote uniformity and collaboration. However, challenges remain in terms of workflow adjustments, language and format variability, and the need for validation. The review concludes by presenting a set of ten essential rules for creating standardized radiology reports, emphasizing clarity, consistency, and adherence to structured formats.


Subject(s)
Radiology , Humans , Radiography , Communication , Language , Workflow
3.
Cancers (Basel) ; 15(9)2023 Apr 22.
Article in English | MEDLINE | ID: mdl-37173880

ABSTRACT

This study aims to evaluate the Average Glandular Dose (AGD) and diagnostic performance of CEM versus Digital Mammography (DM) as well as versus DM plus one-view Digital Breast Tomosynthesis (DBT), which were performed in the same patients at short intervals of time. A preventive screening examination in high-risk asymptomatic patients between 2020 and 2022 was performed with two-view Digital Mammography (DM) projections (Cranio Caudal and Medio Lateral) plus one Digital Breast Tomosynthesis (DBT) projection (mediolateral oblique, MLO) in a single session examination. For all patients in whom we found a suspicious lesion by using DM + DBT, we performed (within two weeks) a CEM examination. AGD and compression force were compared between the diagnostic methods. All lesions identified by DM + DBT were biopsied; then, we assessed whether lesions found by DBT were also highlighted by DM alone and/or by CEM. We enrolled 49 patients with 49 lesions in the study. The median AGD was lower for DM alone than for CEM (3.41 mGy vs. 4.24 mGy, p = 0.015). The AGD for CEM was significantly lower than for the DM plus one single projection DBT protocol (4.24 mGy vs. 5.55 mGy, p < 0.001). We did not find a statistically significant difference in the median compression force between the CEM and DM + DBT. DM + DBT allows the identification of one more invasive neoplasm one in situ lesion and two high-risk lesions, compared to DM alone. The CEM, compared to DM + DBT, failed to identify only one of the high-risk lesions. According to these results, CEM could be used in the screening of asymptomatic high-risk patients.

4.
Cancers (Basel) ; 15(3)2023 Feb 02.
Article in English | MEDLINE | ID: mdl-36765921

ABSTRACT

The study aimed to evaluate the performance of radiomics features and one ultrasound CAD (computer-aided diagnosis) in the prediction of the malignancy of a breast lesion detected with ultrasound and to develop a nomogram incorporating radiomic score and available information on CAD performance, conventional Breast Imaging Reporting and Data System evaluation (BI-RADS), and clinical information. Data on 365 breast lesions referred for breast US with subsequent histologic analysis between January 2020 and March 2022 were retrospectively collected. Patients were randomly divided into a training group (n = 255) and a validation test group (n = 110). A radiomics score was generated from the US image. The CAD was performed in a subgroup of 209 cases. The radiomics score included seven radiomics features selected with the LASSO logistic regression model. The multivariable logistic model incorporating CAD performance, BI-RADS evaluation, clinical information, and radiomic score as covariates showed promising results in the prediction of the malignancy of breast lesions: Area under the receiver operating characteristic curve, [AUC]: 0.914; 95% Confidence Interval, [CI]: 0.876-0.951. A nomogram was developed based on these results for possible future applications in clinical practice.

5.
J Clin Med ; 12(4)2023 Feb 09.
Article in English | MEDLINE | ID: mdl-36835908

ABSTRACT

Recent technological advances in the field of artificial intelligence hold promise in addressing medical challenges in breast cancer care, such as early diagnosis, cancer subtype determination and molecular profiling, prediction of lymph node metastases, and prognostication of treatment response and probability of recurrence. Radiomics is a quantitative approach to medical imaging, which aims to enhance the existing data available to clinicians by means of advanced mathematical analysis using artificial intelligence. Various published studies from different fields in imaging have highlighted the potential of radiomics to enhance clinical decision making. In this review, we describe the evolution of AI in breast imaging and its frontiers, focusing on handcrafted and deep learning radiomics. We present a typical workflow of a radiomics analysis and a practical "how-to" guide. Finally, we summarize the methodology and implementation of radiomics in breast cancer, based on the most recent scientific literature to help researchers and clinicians gain fundamental knowledge of this emerging technology. Alongside this, we discuss the current limitations of radiomics and challenges of integration into clinical practice with conceptual consistency, data curation, technical reproducibility, adequate accuracy, and clinical translation. The incorporation of radiomics with clinical, histopathological, and genomic information will enable physicians to move forward to a higher level of personalized management of patients with breast cancer.

6.
Int J Mol Sci ; 23(23)2022 Dec 05.
Article in English | MEDLINE | ID: mdl-36499648

ABSTRACT

We aimed to investigate the association between the radiomic features of contrast-enhanced spectral mammography (CESM) images and a specific receptor pattern of breast neoplasms. In this single-center retrospective study, we selected patients with neoplastic breast lesions who underwent CESM before a biopsy and surgical assessment between January 2013 and February 2022. Radiomic analysis was performed on regions of interest selected from recombined CESM images. The association between the features and each evaluated endpoint (ER, PR, Ki-67, HER2+, triple negative, G2-G3 expressions) was investigated through univariate logistic regression. Among the significant and highly correlated radiomic features, we selected only the one most associated with the endpoint. From a group of 321 patients, we enrolled 205 malignant breast lesions. The median age at the exam was 50 years (interquartile range (IQR) 45-58). NGLDM_Contrast was the only feature that was positively associated with both ER and PR expression (p-values = 0.01). NGLDM_Coarseness was negatively associated with Ki-67 expression (p-value = 0.02). Five features SHAPE Volume(mL), SHAPE_Volume(vx), GLRLM_RLNU, NGLDM_Busyness and GLZLM_GLNU were all positively and significantly associated with HER2+; however, all of them were highly correlated. Radiomic features of CESM images could be helpful to predict particular molecular subtypes before a biopsy.


Subject(s)
Breast Neoplasms , Humans , Middle Aged , Female , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Retrospective Studies , Ki-67 Antigen , Contrast Media , Mammography/methods
7.
J Clin Med ; 11(24)2022 Dec 09.
Article in English | MEDLINE | ID: mdl-36555950

ABSTRACT

Radiomics investigates the predictive role of quantitative parameters calculated from radiological images. In oncology, tumour segmentation constitutes a crucial step of the radiomic workflow. Manual segmentation is time-consuming and prone to inter-observer variability. In this study, a state-of-the-art deep-learning network for automatic segmentation (nnU-Net) was applied to computed tomography images of lung tumour patients, and its impact on the performance of survival radiomic models was assessed. In total, 899 patients were included, from two proprietary and one public datasets. Different network architectures (2D, 3D) were trained and tested on different combinations of the datasets. Automatic segmentations were compared to reference manual segmentations performed by physicians using the DICE similarity coefficient. Subsequently, the accuracy of radiomic models for survival classification based on either manual or automatic segmentations were compared, considering both hand-crafted and deep-learning features. The best agreement between automatic and manual contours (DICE = 0.78 ± 0.12) was achieved averaging 2D and 3D predictions and applying customised post-processing. The accuracy of the survival classifier (ranging between 0.65 and 0.78) was not statistically different when using manual versus automatic contours, both with hand-crafted and deep features. These results support the promising role nnU-Net can play in automatic segmentation, accelerating the radiomic workflow without impairing the models' accuracy. Further investigations on different clinical endpoints and populations are encouraged to confirm and generalise these findings.

8.
Phys Med ; 97: 13-24, 2022 May.
Article in English | MEDLINE | ID: mdl-35334407

ABSTRACT

PURPOSE: Phantoms mimicking human tissue heterogeneity and intensity are required to establish radiomic features robustness in Computed Tomography (CT) images. We developed inserts with two different techniques for the radiomic study of Non-Small Cell Lung Cancer (NSCLC) lesions. METHODS: We developed two insert prototypes: two 3D-printed made of glycol-modified polyethylene terephthalate (PET-G), and nine with sodium polyacrylate plus iodinated contrast medium. The inserts were put in a handcraft phantom (HeLLePhant). We also analysed four materials of a commercial homogeneous phantom (Catphan® 424) and collected 29 NSCLC patients for comparison. All the CT acquisitions were performed with the same clinical protocol and scanner at 120kVp. The HeLLePhant phantom was scanned ten times in fixed condition at 120kVp and 100kVp for repeatability investigation. We extracted 153 radiomic features using Pyradiomics. To compare the features between phantoms and patients, we computed how many phantom features fell in the range between 10th and 90th percentile of the corresponding patient values. We deemed repeatable the features with a coefficient of variation (CV) less than or equal to 0.10. RESULTS: The best similarity with the patients was obtained with the polyacrylate inserts (55.6-90.2%), the worst with Catphan (15.7-19.0%). For the PET-G inserts 35.3% and 36.6% of the features match the patient range. We found high repeatability for all the inserts of the HeLLePhant phantom (74.3-100% at 120kVp, 75.7-97.9% at 100kVp), and observed a texture dependency in repeatability. CONCLUSIONS: Our study shows a promising way to construct heterogeneous inserts mimicking a target tissue for radiomic studies.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Humans , Image Processing, Computer-Assisted/methods , Lung Neoplasms/diagnostic imaging , Phantoms, Imaging , Tomography, X-Ray Computed/methods
9.
Insights Imaging ; 13(1): 23, 2022 Feb 05.
Article in English | MEDLINE | ID: mdl-35124735

ABSTRACT

The evaluation of radiation burden in vivo is crucial in modern radiology as stated also in the European Directive 2013/59/Euratom-Basic Safety Standard. Although radiation dose monitoring can impact the justification and optimization of radiological procedure, as well as effective patient communication, standardization of radiation monitoring software is far to be achieved. Toward this goal, the Italian Association of Medical Physics (AIFM) published a report describing the state of the art and standard guidelines in radiation dose monitoring system quality assurance. This article reports the AIFM statement about radiation dose monitoring systems (RDMSs) summarizing the different critical points of the systems related to Medical Physicist Expert (MPE) activities before, during, and after their clinical implementation. In particular, the article describes the general aspects of radiation dose data management, radiation dose monitoring systems, data integrity, and data responsibilities. Furthermore, the acceptance tests that need to be implemented and the most relevant dosimetric data for each radiological modalities are reported under the MPE responsibility.

10.
Eur Radiol Exp ; 6(1): 2, 2022 01 25.
Article in English | MEDLINE | ID: mdl-35075539

ABSTRACT

BACKGROUND: We investigated to what extent tube voltage, scanner model, and reconstruction algorithm affect radiomic feature reproducibility in a single-institution retrospective database of computed tomography images of non-small-cell lung cancer patients. METHODS: This study was approved by the Institutional Review Board (UID 2412). Images of 103 patients were considered, being acquired on either among two scanners, at 100 or 120 kVp. For each patient, images were reconstructed with six iterative blending levels, and 1414 features were extracted from each reconstruction. At univariate analysis, Wilcoxon-Mann-Whitney test was applied to evaluate feature differences within scanners and voltages, whereas the impact of the reconstruction was established with the overall concordance correlation coefficient (OCCC). A multivariable mixed model was also applied to investigate the independent contribution of each acquisition/reconstruction parameter. Univariate and multivariable analyses were combined to analyse feature behaviour. RESULTS: Scanner model and voltage did not affect features significantly. The reconstruction blending level showed a significant impact at both univariate analysis (154/1414 features yielding an OCCC < 0.85) and multivariable analysis, with most features (1042/1414) revealing a systematic trend with the blending level (multiple comparisons adjusted p < 0.05). Reproducibility increased in association to image processing with smooth filters, nonetheless specific investigation in relation to clinical endpoints should be performed to ensure that textural information is not removed. CONCLUSIONS: Combining univariate and multivariable models is allowed to identify features for which corrections may be applied to reduce the trend with the algorithm and increase reproducibility. Subsequent clustering may be applied to eliminate residual redundancy.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Humans , Lung Neoplasms/diagnostic imaging , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed
11.
Phys Med ; 91: 28-42, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34710789

ABSTRACT

PURPOSE: The assessment of low-contrast-details is a part of the quality control (QC) program in digital radiology. It generally consists of evaluating the threshold contrast (Cth) detectability details for different-sized inserts, appropriately located in dedicated QC test tools. This work aims to propose a simplified method, based on a statistical model approach for threshold contrast estimation, suitable for different modalities in digital radiology. METHODS: A home-madelow-contrast phantom, made of a central aluminium insert with a step-wedge, was assembled and tested. The reliability and robustness of the method were investigated for Mammography, Digital Radiography, Fluoroscopy and Angiography. Imageswere analysed using our dedicated software developed on Matlab®. TheCth is expressed in the same unit (mmAl) for all studied modalities. RESULTS: This method allows the collection of Cthinformation from different modalities and equipment by different vendors, and it could be used to define typical values. Results are summarized in detail. For 0.5 diameter detail, Cthresults are in the range of: 0.018-0.023 mmAl for 2D mammography and 0.26-0.34 mmAl DR images. For angiographic images, for 2.5 mm diameter detail, the Cths median values are 0.55, 0.4, 0.06, 0.12 mmAl for low dose fluoroscopy, coronary fluorography, cerebral and abdominal DSA, respectively. CONCLUSIONS: The statistical method proposed in this study gives a simple approach for Low-Contrast-Details assessment, and the typical values proposed can be implemented in a QA program for digital radiology modalities.


Subject(s)
Mammography , Radiographic Image Enhancement , Phantoms, Imaging , Quality Control , Reproducibility of Results
12.
Cancers (Basel) ; 13(17)2021 Aug 25.
Article in English | MEDLINE | ID: mdl-34503081

ABSTRACT

OBJECTIVES: We aimed to determine whether radiomic features extracted from a highly homogeneous database of breast MRI could non-invasively predict pathological complete responses (pCR) to neoadjuvant chemotherapy (NACT) in patients with breast cancer. METHODS: One hundred patients with breast cancer receiving NACT in a single center (01/2017-06/2019) and undergoing breast MRI were retrospectively evaluated. For each patient, radiomic features were extracted within the biopsy-proven tumor on T1-weighted (T1-w) contrast-enhanced MRI performed before NACT. The pCR to NACT was determined based on the final surgical specimen. The association of clinical/biological and radiomic features with response to NACT was evaluated by univariate and multivariable analysis by using random forest and logistic regression. The performances of all models were assessed using the areas under the receiver operating characteristic curves (AUC) with 95% confidence intervals (CI). RESULTS: Eighty-three patients (mean (SD) age, 47.26 (8.6) years) were included. Patients with HER2+, basal-like molecular subtypes and Ki67 ≥ 20% presented a pCR to NACT more frequently; the clinical/biological model's AUC (95% CI) was 0.81 (0.71-0.90). Using 136 representative radiomics features selected through cluster analysis from the 1037 extracted features, a radiomic score was calculated to predict the response to NACT, with AUC (95% CI): 0.64 (0.51-0.75). After combining the clinical/biological and radiomics models, the AUC (95% CI) was 0.83 (0.73-0.92). CONCLUSIONS: MRI-based radiomic features slightly improved the pre-treatment prediction of pCR to NACT, in addiction to biological characteristics. If confirmed on larger cohorts, it could be helpful to identify such patients, to avoid unnecessary treatment.

13.
Cancers (Basel) ; 13(12)2021 Jun 21.
Article in English | MEDLINE | ID: mdl-34205631

ABSTRACT

Radiomics uses high-dimensional sets of imaging features to predict biological characteristics of tumors and clinical outcomes. The choice of the algorithm used to analyze radiomic features and perform predictions has a high impact on the results, thus the identification of adequate machine learning methods for radiomic applications is crucial. In this study we aim to identify suitable approaches of analysis for radiomic-based binary predictions, according to sample size, outcome balancing and the features-outcome association strength. Simulated data were obtained reproducing the correlation structure among 168 radiomic features extracted from Computed Tomography images of 270 Non-Small-Cell Lung Cancer (NSCLC) patients and the associated to lymph node status. Performances of six classifiers combined with six feature selection (FS) methods were assessed on the simulated data using AUC (Area Under the Receiver Operating Characteristics Curves), sensitivity, and specificity. For all the FS methods and regardless of the association strength, the tree-based classifiers Random Forest and Extreme Gradient Boosting obtained good performances (AUC ≥ 0.73), showing the best trade-off between sensitivity and specificity. On small samples, performances were generally lower than in large-medium samples and with larger variations. FS methods generally did not improve performances. Thus, in radiomic studies, we suggest evaluating the choice of FS and classifiers, considering specific sample size, balancing, and association strength.

14.
Magn Reson Med ; 85(3): 1713-1726, 2021 03.
Article in English | MEDLINE | ID: mdl-32970859

ABSTRACT

PURPOSE: To investigate the repeatability and reproducibility of radiomic features extracted from MR images and provide a workflow to identify robust features. METHODS: T2 -weighted images of a pelvic phantom were acquired on three scanners of two manufacturers and two magnetic field strengths. The repeatability and reproducibility of features were assessed by the intraclass correlation coefficient and the concordance correlation coefficient, respectively, and by the within-subject coefficient of variation, considering repeated acquisitions with and without phantom repositioning, and with different scanner and acquisition parameters. The features showing intraclass correlation coefficient or concordance correlation coefficient >0.9 were selected, and their dependence on shape information (Spearman's ρ > 0.8) analyzed. They were classified for their ability to distinguish textures, after shuffling voxel intensities of images. RESULTS: From 944 two-dimensional features, 79.9% to 96.4% showed excellent repeatability in fixed position across all scanners. A much lower range (11.2% to 85.4%) was obtained after phantom repositioning. Three-dimensional extraction did not improve repeatability performance. Excellent reproducibility between scanners was observed in 4.6% to 15.6% of the features, at fixed imaging parameters. In addition, 82.4% to 94.9% of the features showed excellent agreement when extracted from images acquired with echo times 5 ms apart, but decreased with increasing echo-time intervals, and 90.7% of the features exhibited excellent reproducibility for changes in pulse repetition time. Of nonshape features, 2.0% was identified as providing only shape information. CONCLUSION: We showed that radiomic features are affected by MRI protocols and propose a general workflow to identify repeatable, reproducible, and informative radiomic features to ensure robustness of clinical studies.


Subject(s)
Magnetic Resonance Imaging , Pelvis , Heart Rate , Pelvis/diagnostic imaging , Phantoms, Imaging , Reproducibility of Results
15.
Cancers (Basel) ; 12(6)2020 May 31.
Article in English | MEDLINE | ID: mdl-32486453

ABSTRACT

BACKGROUND: To evaluate whether a model based on radiomic and clinical features may be associated with lymph node (LN) status and overall survival (OS) in lung cancer (LC) patients; to evaluate whether CT reconstruction algorithms may influence the model performance. METHODS: patients operated on for LC with a pathological stage up to T3N1 were retrospectively selected and divided into training and validation sets. For the prediction of positive LNs and OS, the Least Absolute Shrinkage and Selection Operator (LASSO) logistic regression model was used; univariable and multivariable logistic regression analysis assessed the association of clinical-radiomic variables and endpoints. All tests were repeated after dividing the groups according to the CT reconstruction algorithm. p-values < 0.05 were considered significant. RESULTS: 270 patients were included and divided into training (n = 180) and validation sets (n = 90). Transfissural extension was significantly associated with positive LNs. For OS prediction, high- and low-risk groups were different according to the radiomics score, also after dividing the two groups according to reconstruction algorithms. CONCLUSIONS: a combined clinical-radiomics model was not superior to a single clinical or single radiomics model to predict positive LNs. A radiomics model was able to separate high-risk and low-risk patients for OS; CTs reconstructed with Iterative Reconstructions (IR) algorithm showed the best model performance.

16.
Phys Med ; 71: 71-81, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32092688

ABSTRACT

PURPOSE: To develop a phantom for methodological radiomic investigation on Magnetic Resonance (MR) images of female patients affected by pelvic cancer. METHODS: A pelvis-shaped container was filled with a MnCl2 solution reproducing the relaxation times (T1, T2) of muscle surrounding pelvic malignancies. Inserts simulating multi-textured lesions were embedded in the phantom. The relaxation times of muscle and tumour were measured on an MR scanner on healthy volunteers and patients; T1 and T2 of MnCl2 solutions were evaluated with a relaxometer to find the concentrations providing a match to in vivo relaxation times. Radiomic features were extracted from the phantom inserts and the patients' lesions. Their repeatability was assessed by multiple measurements. RESULTS: Muscle T1 and T2 were 1128 (806-1378) and 51 (40-65) ms, respectively. The phantom reproduced in vivo values within 13% (T1) and 12% (T2). T1 and T2 of tumour tissue were 1637 (1396-2121) and 94 (79-101) ms, respectively. The phantom insert best mimicking the tumour agreed within 7% (T1) and 24% (T2) with in vivo values. Out of 1034 features, 75% (95%) had interclass correlation coefficient greater than 0.9 on T1 (T2)-weighted images, reducing to 33% (25%) if the phantom was repositioned. The most repeatable features on phantom showed values in agreement with the features extracted from patients' lesions. CONCLUSIONS: We developed an MR phantom with inserts mimicking both relaxation times and texture of pelvic tumours. As exemplified with repeatability assessment, such phantom is useful to investigate features robustness and optimise the radiomic workflow on pelvic MR images.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Muscles/diagnostic imaging , Pelvic Neoplasms/diagnostic imaging , Pelvic Neoplasms/radiotherapy , Pelvis/diagnostic imaging , Radiometry , Adult , Chlorides/chemistry , Female , Healthy Volunteers , Humans , Manganese Compounds/chemistry , Middle Aged , Phantoms, Imaging , Reproducibility of Results , Young Adult
17.
Phys Med ; 64: 273-292, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31515030

ABSTRACT

PURPOSE: The Council Directive 2013/59/EURATOM considers interventional radiology to be a special practice involving high doses of radiation and requiring strict monitoring to ensure the best quality assurance programs. This work reports the early experience of managing dose data from patients undergoing angiography in a multicentre study. MATERIALS AND METHODS: The study was based on a survey of about 15,200 sample procedures performed in 21 Italian hospitals centres involved on a voluntary basis. The survey concerned the collection of data related to different interventional radiology procedures: interventional cardiology, radiology, neuroradiology, vascular surgery, urology, endoscopy and pain therapy from a C-Arm and fixed units. The analysis included 11 types of procedures and for each procedure, air-kerma, kerma-area product and fluoroscopy time were collected. RESULTS: The duration and dose values of fluoroscopic exposure for each procedure is strongly dependent on individual clinical circumstances including the complexity of the procedure; the observed distribution of patient doses was very wide, even for a specified protocol. The median values of the parameters were compared with the diagnostic reference levels (DRL) proposed for some procedures in Italy (ISTISAN) or internationally. This work proposes local DRL values for three procedures. CONCLUSION: This first data collection serves to take stock of the situation on patient's dosimetry in several sectors and is the starting point for obtaining and updating DRL recalling that these levels are dependent on experience and technology available.


Subject(s)
Angiography/methods , Radiation Dosage , Radiography, Interventional/methods , Humans , Italy , Time Factors
19.
Eur Radiol Exp ; 2(1): 36, 2018 Nov 14.
Article in English | MEDLINE | ID: mdl-30426318

ABSTRACT

Radiomics is an emerging translational field of research aiming to extract mineable high-dimensional data from clinical images. The radiomic process can be divided into distinct steps with definable inputs and outputs, such as image acquisition and reconstruction, image segmentation, features extraction and qualification, analysis, and model building. Each step needs careful evaluation for the construction of robust and reliable models to be transferred into clinical practice for the purposes of prognosis, non-invasive disease tracking, and evaluation of disease response to treatment. After the definition of texture parameters (shape features; first-, second-, and higher-order features), we briefly discuss the origin of the term radiomics and the methods for selecting the parameters useful for a radiomic approach, including cluster analysis, principal component analysis, random forest, neural network, linear/logistic regression, and other. Reproducibility and clinical value of parameters should be firstly tested with internal cross-validation and then validated on independent external cohorts. This article summarises the major issues regarding this multi-step process, focussing in particular on challenges of the extraction of radiomic features from data sets provided by computed tomography, positron emission tomography, and magnetic resonance imaging.