Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Publication year range
1.
Rev. chil. cardiol ; 41(2): 105-110, ago. 2022. ilus
Article in Spanish | LILACS | ID: biblio-1407756

ABSTRACT

Resumen: El síncope mediado neuralmente es un trastorno causado por un reflejo autónomo anormalmente amplificado que involucra componentes tanto simpáticos como parasimpáticos. Es la causa más frecuente de síncope en personas jóvenes y su tratamiento sigue siendo un desafío, ya que no se ha demostrado que alguna terapia farmacológica prevenga por completo su recurrencia. En los últimos años ha surgido una técnica denominada cardioneuroablación, que consiste en la ablación por radiofrecuencia de los plexos ganglionares (PG) parasimpáticos, con buenos resultados a corto y largo plazo en la prevención de síncope recurrente, según los diferentes grupos de investigación. Presentamos el primer caso en Chile de un hombre joven con síncopes mediados neuralmente recurrentes que fue tratado con esta técnica en el Hospital Regional de Concepción.


Abstract: Cardioneuroablation is a novel method that can be used to treat reflex syncope. Although the experience with this technique is relatively limited it provides a more physiological way to treat this condition. The first case in Chile is herein reported along with a discussion of the subject.


Subject(s)
Humans , Male , Adult , Ablation Techniques/methods , Radiofrequency Ablation/methods , Atropine/pharmacology , Syncope, Vasovagal/diagnosis , Electrocardiography/instrumentation
2.
Heart Rhythm O2 ; 3(6Part B): 731-735, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36589010

ABSTRACT

Background: Transvenous lead extraction is the standard of care for cardiac implantable electronic device (CIED) malfunction/infection-related removal. However, data on its performance and results in underdeveloped countries are limited. Objective: The purpose of this study was to report the feasibility and efficacy of a lead extraction program in a tertiary hospital in Chile, South America. Methods: Patients requiring CIED removal at the Electrophysiology Division of the Hospital las Higuera's were retrospectively analyzed. Outcomes including procedure-related mortality, procedural success and failure, and cardiac and vascular complications were reported. Results: A total of 15 patients were analyzed (median age 68 [interquartile range 52-75] years; 80% male). Patients with lead extraction difficulty index >10 represented 33% of patients. Infection was the indication for removal in all patients, with pocket infection (80%). Mechanical rotational tools were used in 66% of cases, and a total of 29 leads were removed. Procedural success was accomplished in 93% of cases. There was 1 (7%) intraprocedural complication and no procedure-related mortality. Conclusions: The development of a lead management program is feasible, safe, and effective in underdeveloped countries.

SELECTION OF CITATIONS
SEARCH DETAIL