Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 104
1.
Trials ; 25(1): 308, 2024 May 07.
Article En | MEDLINE | ID: mdl-38715118

BACKGROUND: Acute respiratory distress syndrome (ARDS) is a frequent cause of hypoxemic respiratory failure with a mortality rate of approximately 30%. Identifying ARDS subphenotypes based on "focal" or "non-focal" lung morphology has the potential to better target mechanical ventilation strategies of individual patients. However, classifying morphology through chest radiography or computed tomography is either inaccurate or impractical. Lung ultrasound (LUS) is a non-invasive bedside tool that can accurately distinguish "focal" from "non-focal" lung morphology. We hypothesize that LUS-guided personalized mechanical ventilation in ARDS patients leads to a reduction in 90-day mortality compared to conventional mechanical ventilation. METHODS: The Personalized Mechanical Ventilation Guided by UltraSound in Patients with Acute Respiratory Distress Syndrome (PEGASUS) study is an investigator-initiated, international, randomized clinical trial (RCT) that plans to enroll 538 invasively ventilated adult intensive care unit (ICU) patients with moderate to severe ARDS. Eligible patients will receive a LUS exam to classify lung morphology as "focal" or "non-focal". Thereafter, patients will be randomized within 12 h after ARDS diagnosis to receive standard care or personalized ventilation where the ventilation strategy is adjusted to the morphology subphenotype, i.e., higher positive end-expiratory pressure (PEEP) and recruitment maneuvers for "non-focal" ARDS and lower PEEP and prone positioning for "focal" ARDS. The primary endpoint is all-cause mortality at day 90. Secondary outcomes are mortality at day 28, ventilator-free days at day 28, ICU length of stay, ICU mortality, hospital length of stay, hospital mortality, and number of complications (ventilator-associated pneumonia, pneumothorax, and need for rescue therapy). After a pilot phase of 80 patients, the correct interpretation of LUS images and correct application of the intervention within the safe limits of mechanical ventilation will be evaluated. DISCUSSION: PEGASUS is the first RCT that compares LUS-guided personalized mechanical ventilation with conventional ventilation in invasively ventilated patients with moderate and severe ARDS. If this study demonstrates that personalized ventilation guided by LUS can improve the outcomes of ARDS patients, it has the potential to shift the existing one-size-fits-all ventilation strategy towards a more individualized approach. TRIAL REGISTRATION: The PEGASUS trial was registered before the inclusion of the first patient, https://clinicaltrials.gov/ (ID: NCT05492344).


Lung , Randomized Controlled Trials as Topic , Respiration, Artificial , Respiratory Distress Syndrome , Ultrasonography, Interventional , Humans , Respiratory Distress Syndrome/therapy , Respiratory Distress Syndrome/diagnostic imaging , Respiratory Distress Syndrome/mortality , Respiration, Artificial/methods , Lung/diagnostic imaging , Lung/physiopathology , Treatment Outcome , Ultrasonography, Interventional/methods , Time Factors , Multicenter Studies as Topic , Predictive Value of Tests , Precision Medicine/methods
2.
J Clin Med ; 13(7)2024 Mar 29.
Article En | MEDLINE | ID: mdl-38610748

Background: Airway care interventions and prone positioning are used in critically ill patients with coronavirus disease 2019 (COVID-19) admitted to the intensive care unit (ICU) to improve oxygenation and facilitate mucus removal. At the onset of the COVID-19 pandemic, the decision-making process regarding the practice of airway care interventions and prone positioning was challenging. Objective: To provide an overview of the practice of airway care interventions and prone positioning during the second wave of the pandemic in the Netherlands. Method: Web-based survey design. Seventy ICU nurses, each representing one intensive care in the Netherlands, were contacted for participation. Potential items were generated based on a literature search and formulated by a multidisciplinary team. Questions were pilot tested for face and construct validity by four intensive care nurses from four different hospitals. Results: The response rate was 53/77 (69%). This survey revealed widespread use of airway care interventions in the Netherlands in COVID-19 patients, despite questionable benefits. Additionally, prone positioning was used in invasively and non-invasively ventilated patients. Conclusions: The use of airway care interventions and prone positioning is time consuming and comes with the production of waste. Further research is needed to assess the effectiveness, workload, and environmental impact of airway care interventions and prone positioning.

3.
Eur J Anaesthesiol ; 41(6): 438-446, 2024 Jun 01.
Article En | MEDLINE | ID: mdl-38385449

BACKGROUND: Lung protective ventilation is considered standard of care in the intensive care unit. However, modifying the ventilator settings can be challenging and is time consuming. Closed loop modes of ventilation are increasingly attractive for use in critically ill patients. With closed loop ventilation, settings that are typically managed by the ICU professionals are under control of the ventilator's algorithms. OBJECTIVES: To describe the effectiveness, safety, efficacy and workload with currently available closed loop ventilation modes. DESIGN: Systematic review of randomised clinical trials. DATA SOURCES: A comprehensive systematic search in PubMed, Embase and the Cochrane Central register of Controlled Trials search was performed in January 2023. ELIGIBILITY CRITERIA: Randomised clinical trials that compared closed loop ventilation with conventional ventilation modes and reported on effectiveness, safety, efficacy or workload. RESULTS: The search identified 51 studies that met the inclusion criteria. Closed loop ventilation, when compared with conventional ventilation, demonstrates enhanced management of crucial ventilator variables and parameters essential for lung protection across diverse patient cohorts. Adverse events were seldom reported. Several studies indicate potential improvements in patient outcomes with closed loop ventilation; however, it is worth noting that these studies might have been underpowered to conclusively demonstrate such benefits. Closed loop ventilation resulted in a reduction of various aspects associated with the workload of ICU professionals but there have been no studies that studied workload in sufficient detail. CONCLUSIONS: Closed loop ventilation modes are at least as effective in choosing correct ventilator settings as ventilation performed by ICU professionals and have the potential to reduce the workload related to ventilation. Nevertheless, there is a lack of sufficient research to comprehensively assess the overall impact of these modes on patient outcomes, and on the workload of ICU staff.


Intensive Care Units , Randomized Controlled Trials as Topic , Respiration, Artificial , Ventilators, Mechanical , Workload , Humans , Respiration, Artificial/methods , Respiration, Artificial/instrumentation , Randomized Controlled Trials as Topic/methods , Critical Care/methods , Treatment Outcome
4.
Diagnostics (Basel) ; 14(4)2024 Feb 14.
Article En | MEDLINE | ID: mdl-38396460

Serum biomarkers and lung ultrasound are important measures for prognostication and treatment allocation in patients with COVID-19. Currently, there is a paucity of studies investigating relationships between serum biomarkers and ultrasonographic biomarkers derived from lung ultrasound. This study aims to assess correlations between serum biomarkers and lung ultrasound findings. This study is a secondary analysis of four prospective observational studies in adult patients with COVID-19. Serum biomarkers included markers of epithelial injury, endothelial dysfunction and immune activation. The primary outcome was the correlation between biomarker concentrations and lung ultrasound score assessed with Pearson's (r) or Spearman's (rs) correlations. Forty-four patients (67 [41-88] years old, 25% female, 52% ICU patients) were included. GAS6 (rs = 0.39), CRP (rs = 0.42) and SP-D (rs = 0.36) were correlated with lung ultrasound scores. ANG-1 (rs = -0.39) was inversely correlated with lung ultrasound scores. No correlations were found between lung ultrasound score and several other serum biomarkers. In patients with COVID-19, several serum biomarkers of epithelial injury, endothelial dysfunction and immune activation correlated with lung ultrasound findings. The lack of correlations with certain biomarkers could offer opportunities for precise prognostication and targeted therapeutic interventions by integrating these unlinked biomarkers.

5.
Antimicrob Resist Infect Control ; 13(1): 23, 2024 Feb 28.
Article En | MEDLINE | ID: mdl-38419094

BACKGROUND: The application of hand hygiene (HH) and the use of non-sterile gloves (NSG) in daily care is highly intertwined. We aimed (1) to assess the combined application of HH and NSG among nurses and (2) to explore determinants that influence their ability to combine both measures in their care. METHODS: In a multi-methods study, we combined direct observations of care episodes with semi-structured interviews with nurses in two affiliated university hospitals. Topics were based on Flottorp's checklist of determinants of practice. RESULTS: In total, we observed 205 care episodes and interviewed 10 nurses. Observations revealed that the combination of NSG and HH was correctly applied in 19% of care episodes in which a single procedure was executed, and in 2% of care episodes in which multiple procedures were performed. From the interviews, we found determinants that influenced compliance, covered mainly by three out of seven of Flottorp's checklist domains. Nurses indicated that their knowledge of protocols was limited to HH and protocols were hardly ever actively consulted; visual reminders within their workplace were used as sources of information. Nurses' behavior was primarily influenced by their ability to operationalize this information and their ability to integrate both infection prevention measures into their care. The intention to apply and combine HH and NSG use was influenced by their risk assessment of cross-contamination, by the urge to self-protect and gut feeling. The feasibility to execute HH and NSG protocols is influenced by the urgency and the complexity of the care episode. CONCLUSIONS: The combined correct application with HH and NSG measures by nurses is low. Nurses are instructed in a fragmented way while in the day to day care HH and NSG use are highly intertwined. Operationalization and simplification of infection prevention protocols, in which instructions on both infection prevention measures are fused, should be considered. Strategies to improve practice should consider the power of habit and nurses urge to self-protect.


Cross Infection , Hand Hygiene , Humans , Hand Hygiene/methods , Tertiary Care Centers , Cross Infection/prevention & control , Health Personnel , Referral and Consultation
6.
Respir Care ; 2024 May 07.
Article En | MEDLINE | ID: mdl-38296330

BACKGROUND: Endotracheal suctioning causes discomfort, is associated with adverse effects, and is resource-demanding. An artificial secretion removal method, known as an automated cough, has been developed, which applies rapid, automated deflation, and inflation of the endotracheal tube cuff during the inspiratory phase of mechanical ventilation. This method has been evaluated in the hands of researchers but not when used by attending nurses. The aim of this study was to explore the efficacy of the method over the course of patient management as part of routine care. METHODS: This prospective, longitudinal, interventional study recruited 28 subjects who were intubated and mechanically ventilated. For a maximum of 7 d and on clinical need for endotracheal suctioning, the automatic cough procedure was applied. The subjects were placed in a pressure-regulated ventilation mode with elevated inspiratory pressure, and automated cuff deflation and inflation were performed 3 times, with this repeated if deemed necessary. Success was determined by resolution of the clinical need for suctioning as determined by the attending nurse. Adverse effects were recorded. RESULTS: A total of 84 procedures were performed. In 54% of the subjects, the artificial cough procedure was successful on > 70% of occasions, with 56% of all procedures considered successful. Ninety percent of all the procedures were performed in subjects who were spontaneously breathing and on pressure-support ventilation with peak inspiratory pressures of 20 cm H2O. Rates of adverse events were similar to those seen in the application of endotracheal suctioning. CONCLUSIONS: This study solely evaluated the efficacy of an automated artificial cough procedure, which illustrated the potential for reducing the need for endotracheal suctioning when applied by attending nurses in routine care.

8.
Nurs Crit Care ; 29(1): 219-225, 2024 01.
Article En | MEDLINE | ID: mdl-37144426

BACKGROUND: INTELLiVENT-adaptive support ventilation (ASV) is an automated closed-loop mode of invasive ventilation for use in critically ill patients. INTELLiVENT-ASV automatically adjusts, without the intervention of the caregiver, ventilator settings to achieve the lowest work and force of breathing. AIMS: The aim of this case series is to describe the specific adjustments of INTELLiVENT-ASV in patients with acute hypoxemic respiratory failure, who were intubated for invasive ventilation. STUDY DESIGN: We describe three patients with severe acute respiratory distress syndrome (ARDS) because of COVID-19 who received invasive ventilation in our intensive care unit (ICU) in the first year of the COVID-19 pandemic. RESULTS: INTELLiVENT-ASV could be used successfully, but only after certain adjustments in the settings of the ventilator. Specifically, the high oxygen targets that are automatically chosen by INTELLiVENT-ASV when the lung condition 'ARDS' is ticked had to be lowered, and the titration ranges for positive end expiratory pressure (PEEP) and inspired oxygen fraction (FiO2 ) had to be narrowed. CONCLUSIONS: The challenges taught us how to adjust the ventilator settings so that INTELLiVENT-ASV could be used in successive COVID-19 ARDS patients, and we experienced the benefits of this closed-loop ventilation in clinical practice. RELEVANCE TO CLINICAL PRACTICE: INTELLiVENT-ASV is attractive to use in clinical practice. It is safe and effective in providing lung-protective ventilation. A closely observing user always remains needed. INTELLiVENT-ASV has a strong potential to reduce the workload associated with ventilation because of the automated adjustments.


COVID-19 , Respiratory Distress Syndrome , Respiratory Insufficiency , Humans , Pandemics , COVID-19/therapy , Lung , Respiration, Artificial , Respiratory Insufficiency/therapy , Respiratory Distress Syndrome/therapy , Oxygen
9.
Crit Care Med ; 52(2): e100-e104, 2024 02 01.
Article En | MEDLINE | ID: mdl-37962157

OBJECTIVES: To assess the effect of incorporating bilateral abnormalities as detected by lung ultrasound (LUS) in the Kigali modification and the New Global definition of acute respiratory distress syndrome (ARDS) on the occurrence rate of ARDS. DESIGN: Post hoc analysis of a previously published prospective cohort study. SETTING: An academic mixed medical-surgical ICU. PATIENTS: The original study included critically ill adults with any opacity on chest radiography in whom subsequent LUS was performed. Patients with ARDS according to the Berlin definition, COVID-19 patients and patients with major thorax trauma were excluded. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: LUS was performed within 24 hours of chest radiography and the presence of unilateral and bilateral abnormalities on LUS and chest radiograph (opacities) was scored. Subsequently, the Kigali modification and the New Global definition of ARDS were applied by two independent researchers on the patients with newly found bilateral opacities. Of 120 patients, 116 were included in this post hoc analysis. Thirty-three patients had bilateral opacities on LUS and unilateral opacities on chest radiograph. Fourteen of these patients had ARDS according to the Kigali modification and 12 had ARDS according to the New Global definition. The detected LUS patterns were significantly different between patients with and without ARDS ( p = 0.004). An A-profile with a positive PosteroLateral Alveolar and/or Pleural Syndrome was most prevalent in patients without ARDS, whereas heterogeneous and mixed A, B, and C patterns were most prevalent in patients with ARDS. CONCLUSION: The addition of bilateral abnormalities as detected by LUS to the Kigali modification and the New Global definition increases the occurrence rate of the ARDS. The nomenclature for LUS needs to be better defined as LUS patterns differ between patients with and without ARDS. Incorporating well-defined LUS criteria can increase specificity and sensitivity of new ARDS definitions.


Lung , Respiratory Distress Syndrome , Adult , Humans , Prospective Studies , Rwanda , Lung/diagnostic imaging , Respiratory Distress Syndrome/diagnostic imaging , Respiratory Distress Syndrome/epidemiology , Thorax , Ultrasonography
10.
J Clin Med ; 12(18)2023 09 05.
Article En | MEDLINE | ID: mdl-37762725

Chronic obstructive pulmonary disease (COPD) is a risk factor for death in patients admitted to intensive care units (ICUs) for respiratory support. Previous reports suggested higher mortality in COPD patients with COVID-19. It is yet unknown whether patients with COPD were treated differently compared to non-COPD patients. We compared the ventilation management and outcomes of invasive ventilation for COVID-19 in COPD patients versus non-COPD patients. This was a post hoc analysis of a nation-wide, observational study in the Netherlands. COPD patients were compared to non-COPD patients with respect to key ventilation parameters. The secondary endpoints included adjunctive treatments for refractory hypoxemia, and 28-day mortality. Of a total of 1090 patients, 88 (8.1%) were classified as having COPD. The ventilation parameters were not different between COPD patients and non-COPD patients, except for FiO2, which was higher in COPD patients. Prone positioning was applied more often in COPD patients. COPD patients had higher 28-day mortality than non-COPD patients. COPD had an independent association with 28-day mortality. In this cohort of patients who received invasive ventilation for COVID-19, only FiO2 settings and the use of prone positioning were different between COPD patients and non-COPD patients. COPD patients had higher mortality than non-COPD patients.

11.
Am J Respir Crit Care Med ; 208(7): 770-779, 2023 10 01.
Article En | MEDLINE | ID: mdl-37552556

Rationale: Supplemental oxygen is widely administered to ICU patients, but appropriate oxygenation targets remain unclear. Objectives: This study aimed to determine whether a low-oxygenation strategy would lower 28-day mortality compared with a high-oxygenation strategy. Methods: This randomized multicenter trial included mechanically ventilated ICU patients with an expected ventilation duration of at least 24 hours. Patients were randomized 1:1 to a low-oxygenation (PaO2, 55-80 mm Hg; or oxygen saturation as measured by pulse oximetry, 91-94%) or high-oxygenation (PaO2, 110-150 mm Hg; or oxygen saturation as measured by pulse oximetry, 96-100%) target until ICU discharge or 28 days after randomization, whichever came first. The primary outcome was 28-day mortality. The study was stopped prematurely because of the COVID-19 pandemic when 664 of the planned 1,512 patients were included. Measurements and Main Results: Between November 2018 and November 2021, a total of 664 patients were included in the trial: 335 in the low-oxygenation group and 329 in the high-oxygenation group. The median achieved PaO2 was 75 mm Hg (interquartile range, 70-84) and 115 mm Hg (interquartile range, 100-129) in the low- and high-oxygenation groups, respectively. At Day 28, 129 (38.5%) and 114 (34.7%) patients had died in the low- and high-oxygenation groups, respectively (risk ratio, 1.11; 95% confidence interval, 0.9-1.4; P = 0.30). At least one serious adverse event was reported in 12 (3.6%) and 17 (5.2%) patients in the low- and high-oxygenation groups, respectively. Conclusions: Among mechanically ventilated ICU patients with an expected mechanical ventilation duration of at least 24 hours, using a low-oxygenation strategy did not result in a reduction of 28-day mortality compared with a high-oxygenation strategy. Clinical trial registered with the National Trial Register and the International Clinical Trials Registry Platform (NTR7376).


COVID-19 , Pandemics , Humans , COVID-19/therapy , Critical Care , Oximetry , Intensive Care Units , Respiration, Artificial
12.
J Clin Med ; 12(13)2023 Jul 05.
Article En | MEDLINE | ID: mdl-37445542

The aim of this analysis was to compare ventilation management and outcomes in invasively ventilated patients with acute hypoxemic respiratory failure due to coronavirus disease 2019 (COVID-19) between the first and second wave in the Netherlands. This is a post hoc analysis of two nationwide observational COVID-19 studies conducted in quick succession. The primary endpoint was ventilation management. Secondary endpoints were tracheostomy use, duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), and mortality. We used propensity score matching to control for observed confounding factors. This analysis included 1122 patients from the first and 568 patients from the second wave. Patients in the second wave were sicker, had more comorbidities, and had worse oxygenation parameters. They were ventilated with lower positive end-expiratory pressure and higher fraction inspired oxygen, had a lower oxygen saturation, received neuromuscular blockade more often, and were less often tracheostomized. Duration of ventilation was shorter, but mortality rates were similar. After matching, the fraction of inspired oxygen was lower in the second wave. In patients with acute hypoxemic respiratory failure due to COVID-19, aspects of respiratory care and outcomes rapidly changed over the successive waves.

13.
Intensive Care Med Exp ; 11(1): 42, 2023 Jul 14.
Article En | MEDLINE | ID: mdl-37442844

INTRODUCTION: The driving pressure (ΔP) has an independent association with outcome in patients with acute respiratory distress syndrome (ARDS). INTELLiVENT-Adaptive Support Ventilation (ASV) is a closed-loop mode of ventilation that targets the lowest work and force of breathing. AIM: To compare transpulmonary and respiratory system ΔP between closed-loop ventilation and conventional pressure controlled ventilation in patients with moderate-to-severe ARDS. METHODS: Single-center randomized cross-over clinical trial in patients in the early phase of ARDS. Patients were randomly assigned to start with a 4-h period of closed-loop ventilation or conventional ventilation, after which the alternate ventilation mode was selected. The primary outcome was the transpulmonary ΔP; secondary outcomes included respiratory system ΔP, and other key parameters of ventilation. RESULTS: Thirteen patients were included, and all had fully analyzable data sets. Compared to conventional ventilation, with closed-loop ventilation the median transpulmonary ΔP with was lower (7.0 [5.0-10.0] vs. 10.0 [8.0-11.0] cmH2O, mean difference - 2.5 [95% CI - 2.6 to - 2.1] cmH2O; P = 0.0001). Inspiratory transpulmonary pressure and the respiratory rate were also lower. Tidal volume, however, was higher with closed-loop ventilation, but stayed below generally accepted safety cutoffs in the majority of patients. CONCLUSIONS: In this small physiological study, when compared to conventional pressure controlled ventilation INTELLiVENT-ASV reduced the transpulmonary ΔP in patients in the early phase of moderate-to-severe ARDS. This closed-loop ventilation mode also led to a lower inspiratory transpulmonary pressure and a lower respiratory rate, thereby reducing the intensity of ventilation. Trial registration Clinicaltrials.gov, NCT03211494, July 7, 2017. https://clinicaltrials.gov/ct2/show/NCT03211494?term=airdrop&draw=2&rank=1 .

14.
Ann Intensive Care ; 13(1): 64, 2023 Jul 14.
Article En | MEDLINE | ID: mdl-37452196

BACKGROUND: High-flow nasal oxygen (HFNO) is increasingly used in patients with acute hypoxemic respiratory failure. It is uncertain whether a broadened Berlin definition of acute respiratory distress syndrome (ARDS), in which ARDS can be diagnosed in patients who are not receiving ventilation, results in similar groups of patients receiving HFNO as in patients receiving ventilation. METHODS: We applied a broadened definition of ARDS in a multicenter, observational study in adult critically ill patients with acute hypoxemic respiratory failure due to coronavirus disease 2019 (COVID-19), wherein the requirement for a minimal level of 5 cm H2O PEEP with ventilation is replaced by a minimal level of airflow rate with HFNO, and compared baseline characteristics and outcomes between patients receiving HFNO and patients receiving ventilation. The primary endpoint was ICU mortality. We also compared outcomes in risk for death groups using the PaO2/FiO2 cutoffs as used successfully in the original definition of ARDS. Secondary endpoints were hospital mortality; mortality on days 28 and 90; need for ventilation within 7 days in patients that started with HFNO; the number of days free from HFNO or ventilation; and ICU and hospital length of stay. RESULTS: Of 728 included patients, 229 patients started with HFNO and 499 patients with ventilation. All patients fulfilled the broadened Berlin definition of ARDS. Patients receiving HFNO had lower disease severity scores and lower PaO2/FiO2 than patients receiving ventilation. ICU mortality was lower in receiving HFNO (22.7 vs 35.6%; p = 0.001). Using PaO2/FiO2 cutoffs for mild, moderate and severe arterial hypoxemia created groups with an ICU mortality of 16.7%, 22.0%, and 23.5% (p = 0.906) versus 19.1%, 37.9% and 41.4% (p = 0.002), in patients receiving HFNO versus patients receiving ventilation, respectively. CONCLUSIONS: Using a broadened definition of ARDS may facilitate an earlier diagnosis of ARDS in patients receiving HFNO; however, ARDS patients receiving HFNO and ARDS patients receiving ventilation have distinct baseline characteristics and mortality rates. TRIAL REGISTRATION: The study is registered at ClinicalTrials.gov (identifier NCT04719182).

15.
JMIR Res Protoc ; 12: e48183, 2023 06 02.
Article En | MEDLINE | ID: mdl-37266993

BACKGROUND: In hospitalized patients with COVID-19, the dosing and timing of corticosteroids vary widely. Low-dose dexamethasone therapy reduces mortality in patients requiring respiratory support, but it remains unclear how to treat patients when this therapy fails. In critically ill patients, high-dose corticosteroids are often administered as salvage late in the disease course, whereas earlier administration may be more beneficial in preventing disease progression. Previous research has revealed that increased levels of various biomarkers are associated with mortality, and whole blood transcriptome sequencing has the ability to identify host factors predisposing to critical illness in patients with COVID-19. OBJECTIVE: Our goal is to determine the most optimal dosing and timing of corticosteroid therapy and to provide a basis for personalized corticosteroid treatment regimens to reduce morbidity and mortality in hospitalized patients with COVID-19. METHODS: This is a retrospective, observational, multicenter study that includes adult patients who were hospitalized due to COVID-19 in the Netherlands. We will use the differences in therapeutic strategies between hospitals (per protocol high-dose corticosteroids or not) over time to determine whether high-dose corticosteroids have an effect on the following outcome measures: mechanical ventilation or high-flow nasal cannula therapy, in-hospital mortality, and 28-day survival. We will also explore biomarker profiles in serum and bronchoalveolar lavage fluid and use whole blood transcriptome analysis to determine factors that influence the relationship between high-dose corticosteroids and outcome. Existing databases that contain routinely collected electronic data during ward and intensive care admissions, as well as existing biobanks, will be used. We will apply longitudinal modeling appropriate for each data structure to answer the research questions at hand. RESULTS: As of April 2023, data have been collected for a total of 1500 patients, with data collection anticipated to be completed by December 2023. We expect the first results to be available in early 2024. CONCLUSIONS: This study protocol presents a strategy to investigate the effect of high-dose corticosteroids throughout the entire clinical course of hospitalized patients with COVID-19, from hospital admission to the ward or intensive care unit until hospital discharge. Moreover, our exploration of biomarker and gene expression profiles for targeted corticosteroid therapy represents a first step towards personalized COVID-19 corticosteroid treatment. TRIAL REGISTRATION: ClinicalTrials.gov NCT05403359; https://clinicaltrials.gov/ct2/show/NCT05403359. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/48183.

16.
Diagnostics (Basel) ; 13(12)2023 Jun 07.
Article En | MEDLINE | ID: mdl-37370885

BACKGROUND: Ventilation with lower positive end-expiratory pressure (PEEP) may cause loss of lung aeration in critically ill invasively ventilated patients. This study investigated whether a systematic lung ultrasound (LUS) scoring system can detect such changes in lung aeration in a study comparing lower versus higher PEEP in invasively ventilated patients without acute respiratory distress syndrome (ARDS). METHODS: Single center substudy of a national, multicenter, randomized clinical trial comparing lower versus higher PEEP ventilation strategy. Fifty-seven patients underwent a systematic 12-region LUS examination within 12 h and between 24 to 48 h after start of invasive ventilation, according to randomization. The primary endpoint was a change in the global LUS aeration score, where a higher value indicates a greater impairment in lung aeration. RESULTS: Thirty-three and twenty-four patients received ventilation with lower PEEP (median PEEP 1 (0-5) cm H2O) or higher PEEP (median PEEP 8 (8-8) cm H2O), respectively. Median global LUS aeration scores within 12 h and between 24 and 48 h were 8 (4 to 14) and 9 (4 to 12) (difference 1 (-2 to 3)) in the lower PEEP group, and 7 (2-11) and 6 (1-12) (difference 0 (-2 to 3)) in the higher PEEP group. Neither differences in changes over time nor differences in absolute scores reached statistical significance. CONCLUSIONS: In this substudy of a randomized clinical trial comparing lower PEEP versus higher PEEP in patients without ARDS, LUS was unable to detect changes in lung aeration.

17.
BMJ Open ; 13(5): e061832, 2023 05 02.
Article En | MEDLINE | ID: mdl-37130670

INTRODUCTION: Hypotension is common during cardiac surgery and often persists postoperatively in the intensive care unit (ICU). Still, treatment is mainly reactive, causing a delay in its management. The Hypotension Prediction Index (HPI) can predict hypotension with high accuracy. Using the HPI combined with a guidance protocol resulted in a significant reduction in the severity of hypotension in four non-cardiac surgery trials. This randomised trial aims to evaluate the effectiveness of the HPI in combination with a diagnostic guidance protocol on reducing the occurrence and severity of hypotension during coronary artery bypass grafting (CABG) surgery and subsequent ICU admission. METHODS AND ANALYSIS: This is a single-centre, randomised clinical trial in adult patients undergoing elective on-pump CABG surgery with a target mean arterial pressure of 65 mm Hg. One hundred and thirty patients will be randomly allocated in a 1:1 ratio to either the intervention or control group. In both groups, a HemoSphere patient monitor with embedded HPI software will be connected to the arterial line. In the intervention group, HPI values of 75 or above will initiate the diagnostic guidance protocol, both intraoperatively and postoperatively in the ICU during mechanical ventilation. In the control group, the HemoSphere patient monitor will be covered and silenced. The primary outcome is the time-weighted average of hypotension during the combined study phases. ETHICS AND DISSEMINATION: The medical research ethics committee and the institutional review board of the Amsterdam UMC, location AMC, the Netherlands, approved the trial protocol (NL76236.018.21). No publication restrictions apply, and the study results will be disseminated through a peer-reviewed journal. TRIAL REGISTRATION NUMBER: The Netherlands Trial Register (NL9449), ClinicalTrials.gov (NCT05821647).


Cardiac Surgical Procedures , Hypotension , Adult , Humans , Hypotension/diagnosis , Hypotension/etiology , Cardiac Surgical Procedures/adverse effects , Arterial Pressure , Elective Surgical Procedures/adverse effects , Machine Learning , Randomized Controlled Trials as Topic
18.
Diagnostics (Basel) ; 13(6)2023 03 17.
Article En | MEDLINE | ID: mdl-36980464

Subcutaneous emphysema, pneumothorax and pneumomediastinum are well-known complications of invasive ventilation in patients with acute hypoxemic respiratory failure. We determined the incidences of air leaks that were visible on available chest images in a cohort of critically ill patients with acute hypoxemic respiratory failure due to coronavirus disease of 2019 (COVID-19) in a single-center cohort in the Netherlands. A total of 712 chest images from 154 patients were re-evaluated by a multidisciplinary team of independent assessors; there was a median of three (2-5) chest radiographs and a median of one (1-2) chest CT scans per patient. The incidences of subcutaneous emphysema, pneumothoraxes and pneumomediastinum present in 13 patients (8.4%) were 4.5%, 4.5%, and 3.9%. The median first day of the presence of an air leak was 18 (2-21) days after arrival in the ICU and 18 (9-22)days after the start of invasive ventilation. We conclude that the incidence of air leaks was high in this cohort of COVID-19 patients, but it was fairly comparable with what was previously reported in patients with acute hypoxemic respiratory failure in the pre-COVID-19 era.

19.
Trials ; 24(1): 226, 2023 Mar 24.
Article En | MEDLINE | ID: mdl-36964614

BACKGROUND: Fluid therapy is a common intervention in critically ill patients. It is increasingly recognised that deresuscitation is an essential part of fluid therapy and delayed deresuscitation is associated with longer invasive ventilation and length of intensive care unit (ICU) stay. However, optimal timing and rate of deresuscitation remain unclear. Lung ultrasound (LUS) may be used to identify fluid overload. We hypothesise that daily LUS-guided deresuscitation is superior to deresuscitation without LUS in critically ill patients expected to undergo invasive ventilation for more than 24 h in terms of ventilator free-days and being alive at day 28. METHODS: The "effect of lung ultrasound-guided fluid deresuscitation on duration of ventilation in intensive care unit patients" (CONFIDENCE) is a national, multicentre, open-label, randomised controlled trial (RCT) in adult critically ill patients that are expected to be invasively ventilated for at least 24 h. Patients with conditions that preclude a negative fluid balance or LUS examination are excluded. CONFIDENCE will operate in 10 ICUs in the Netherlands and enrol 1000 patients. After hemodynamic stabilisation, patients assigned to the intervention will receive daily LUS with fluid balance recommendations. Subjects in the control arm are deresuscitated at the physician's discretion without the use of LUS. The primary endpoint is the number of ventilator-free days and being alive at day 28. Secondary endpoints include the duration of invasive ventilation; 28-day mortality; 90-day mortality; ICU, in hospital and total length of stay; cumulative fluid balance on days 1-7 after randomisation and on days 1-7 after start of LUS examination; mean serum lactate on days 1-7; the incidence of reintubations, chest drain placement, atrial fibrillation, kidney injury (KDIGO stadium ≥ 2) and hypernatremia; the use of invasive hemodynamic monitoring, and chest-X-ray; and quality of life at day 28. DISCUSSION: The CONFIDENCE trial is the first RCT comparing the effect of LUS-guided deresuscitation to routine care in invasively ventilated ICU patients. If proven effective, LUS-guided deresuscitation could improve outcomes in some of the most vulnerable and resource-intensive patients in a manner that is non-invasive, easy to perform, and well-implementable. TRIAL REGISTRATION: ClinicalTrials.gov NCT05188092. Registered since January 12, 2022.


Critical Illness , Lung , Adult , Humans , Lung/diagnostic imaging , Critical Care/methods , Respiration, Artificial/methods , Intensive Care Units , Ultrasonography, Interventional , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
20.
Am J Trop Med Hyg ; 108(5): 1035-1041, 2023 05 03.
Article En | MEDLINE | ID: mdl-36972693

The COVID-19 pandemic led to local oxygen shortages worldwide. To gain a better understanding of oxygen consumption with different respiratory supportive therapies, we conducted an international multicenter observational study to determine the precise amount of oxygen consumption with high-flow nasal oxygen (HFNO) and with mechanical ventilation. A retrospective observational study was conducted in three intensive care units (ICUs) in the Netherlands and Spain. Patients were classified as HFNO patients or ventilated patients, according to the mode of oxygen supplementation with which a patient started. The primary endpoint was actual oxygen consumption; secondary endpoints were hourly and total oxygen consumption during the first two full calendar days. Of 275 patients, 147 started with HFNO and 128 with mechanical ventilation. Actual oxygen use was 4.9-fold higher in patients who started with HFNO than in patients who started with ventilation (median 14.2 [8.4-18.4] versus 2.9 [1.8-4.1] L/minute; mean difference = 11.3 [95% CI 11.0-11.6] L/minute; P < 0.01). Hourly and total oxygen consumption were 4.8-fold (P < 0.01) and 4.8-fold (P < 0.01) higher. Actual oxygen consumption, hourly oxygen consumption, and total oxygen consumption are substantially higher in patients that start with HFNO compared with patients that start with mechanical ventilation. This information may help hospitals and ICUs predicting oxygen needs during high-demand periods and could guide decisions regarding the source of distribution of medical oxygen.


COVID-19 , Oxygen , Humans , Oxygen/therapeutic use , COVID-19/therapy , Respiration, Artificial , Pandemics , Oxygen Consumption
...