Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 117
Filter
1.
Article in English | MEDLINE | ID: mdl-38934970

ABSTRACT

BACKGROUND: Ventricular tachycardia (VT), which can lead to sudden cardiac death, occurs frequently in patients after myocardial infarction. Radiofrequency catheter ablation (RFA) is a modestly effective treatment of VT, but it has limitations and risks. Cardiac magnetic resonance (CMR)-based heart digital twins have emerged as a useful tool for identifying VT circuits for RFA treatment planning. However, the CMR resolution used to reconstruct these digital twins may impact VT circuit predictions, leading to incorrect RFA treatment planning. OBJECTIVES: This study sought to predict RFA targets in the arrhythmogenic substrate using heart digital twins reconstructed from both clinical and high-resolution 2-dimensional CMR datasets and compare the predictions. METHODS: High-resolution (1.35 × 1.35 × 3 mm), or oversampled resolution (Ov-Res), short-axis late gadolinium-enhanced CMR was acquired by combining 2 subsequent clinical resolution (Clin-Res) (1.35 × 1.35 × 6 mm) short-axis late gadolinium-enhanced CMR scans from 6 post-myocardial infarction patients undergoing VT ablation and used to reconstruct a total of 3 digital twins (1 Ov-Res, 2 Clin-Res) for each patient. Rapid pacing was used to assess VT circuits and identify the optimal ablation targets in each digital twin. VT circuits predicted by the digital twins were compared with intraprocedural electroanatomic mapping data and used to identify emergent VT. RESULTS: The Ov-Res digital twins reduced partial volume effects and better predicted unique VT circuits compared with the Clin-Res digital twins (66.6% vs 54.5%; P < 0.01). Only the Ov-Res digital twin successfully identified emergent VT after a failed initial ablation. CONCLUSIONS: Digital twin infarct geometry and VT circuit predictions depend on the magnetic resonance resolution. Ov-Res digital twins better predict VT circuits and emergent VT, which may improve RFA outcomes.

2.
Rev Med Suisse ; 20(868): 682-687, 2024 Apr 03.
Article in French | MEDLINE | ID: mdl-38568060

ABSTRACT

The diagnosis of cardiac sarcoidosis, particularly in its isolated cardiac form, represents a major challenge due to non-specific symptoms and the limited sensitivity and specificity of basic cardiac investigations. MRI and metabolic PET-CT are important elements in the diagnostic process. Corticosteroids remain the cornerstone for the treatment of the inflammatory phase, in association with biological agents and steroid-sparing therapies. The goal is to limit the progression of fibrosis, which is a source of malignant arrhythmias and heart failure. The indication for implantation of a cardiac defibrillator must be carefully evaluated to reduce the risk of sudden death. Multidisciplinary collaboration is essential for optimal care.


Le diagnostic de sarcoïdose cardiaque, en particulier dans sa forme cardiaque isolée, représente un défi majeur en raison de symptômes aspécifiques et d'une sensibilité et spécificité limitées des explorations cardiologiques de base. L'IRM et le PET-CT métabolique sont devenus des éléments essentiels dans le processus diagnostique. Les corticostéroïdes restent la pierre angulaire du traitement dans la phase inflammatoire, parallèlement aux agents biologiques et aux thérapies d'épargne cortisonique. L'objectif est d'éviter la progression vers la fibrose, source d'arythmies malignes et d'insuffisance cardiaque. L'indication à l'implantation d'un défibrillateur cardiaque doit être soigneusement évaluée afin de réduire le risque de mort subite. Une collaboration multidisciplinaire est essentielle afin d'assurer une prise en charge optimale.


Subject(s)
Heart Failure , Myocarditis , Sarcoidosis , Humans , Positron Emission Tomography Computed Tomography , Heart , Sarcoidosis/diagnosis , Sarcoidosis/therapy
3.
Pacing Clin Electrophysiol ; 47(5): 614-625, 2024 May.
Article in English | MEDLINE | ID: mdl-38558218

ABSTRACT

INTRODUCTION: The use of esophageal temperature monitoring (ETM) for the prevention of esophageal injury during atrial fibrillation (AF) ablation is often advocated. However, evidence supporting its use is scarce and controversial. We therefore aimed to review the evidence assessing the efficacy of ETM for the prevention of esophageal injury. METHODS: We performed a meta-analysis and systematic review of the available literature from inception to December 31, 2022. All studies comparing the use of ETM, versus no ETM, during radiofrequency (RF) AF ablation and which reported the incidence of endoscopically detected esophageal lesions (EDELs) were included. RESULTS: Eleven studies with a total of 1112 patients undergoing RF AF ablation were identified. Of those patients, 627 were assigned to ETM (56%). The overall incidence of EDELs was 9.8%. The use of ETM during AF ablation was associated with a non significant increase in the incidence of EDELs (12.3% with ETM, vs. 6.6 % without ETM, odds ratio, 1.44, 95%CI, 0.49, 4.22, p = .51, I2 = 72%). The use of ETM was associated with a significant increase in the energy delivered specifically on the posterior wall compared to patients without ETM (mean power difference: 5.13 Watts, 95% CI, 1.52, 8.74, p = .005). CONCLUSIONS: The use of ETM does not reduce the incidence of EDELs during RF AF ablation. The higher energy delivered on the posterior wall is likely attributable to a false sense of safety that may explain the lack of benefit of ETM. Further randomized controlled trials are needed to provide conclusive results.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Esophagus , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/prevention & control , Esophagus/injuries , Body Temperature , Monitoring, Intraoperative/methods , Intraoperative Complications/prevention & control
4.
Strahlenther Onkol ; 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38652131

ABSTRACT

This preliminary ethical appraisal from the STOPSTORM.eu consortium is meant to raise critical points that clinicians administering stereotactic arrhythmia radioablation should consider to meet the highest standards in medical ethics and thus promote quality of life of patients recruited for radiotherapy treatments at a stage in which they experience a significant degree of vulnerability.

5.
Rev Med Suisse ; 20(856-7): 19-24, 2024 Jan 17.
Article in French | MEDLINE | ID: mdl-38231094

ABSTRACT

The year 2023 has been extremely rich in new publications in the various subfields of cardiology. Furthermore, the European Society of Cardiology (ESC) has issued revised guidelines focused on the management of acute coronary syndrome (ACS) and endocarditis, as well as an update on the recommendations for the management of heart failure and cardiovascular prevention. The most significant updates according to the Cardiology Department of CHUV are summarized in this review article.


L'année 2023 a été extrêmement riche en nouvelles publications dans les différents sous-domaines de la cardiologie. De plus, la Société européenne de cardiologie (ESC) a formulé des directives révisées axées sur le management du syndrome coronarien aigu (SCA) et de l'endocardite ainsi qu'une mise à jour des recommandations sur la prise en charge de l'insuffisance cardiaque et la prévention cardiovasculaire. Les nouveautés les plus importantes selon l'équipe du Service de cardiologie du CHUV sont résumées dans cet article de synthèse.


Subject(s)
Acute Coronary Syndrome , Cardiology , Endocarditis , Heart Failure , Humans , Heart Failure/diagnosis , Heart Failure/therapy , Acute Coronary Syndrome/diagnosis , Acute Coronary Syndrome/therapy
6.
Physiol Meas ; 45(2)2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38266291

ABSTRACT

Objective.Cardiac arrhythmias are a leading cause of mortality worldwide. Wearable devices based on photoplethysmography give the opportunity to screen large populations, hence allowing for an earlier detection of pathological rhythms that might reduce the risks of complications and medical costs. While most of beat detection algorithms have been evaluated on normal sinus rhythm or atrial fibrillation recordings, the performance of these algorithms in patients with other cardiac arrhythmias, such as ventricular tachycardia or bigeminy, remain unknown to date.Approach. ThePPG-beatsopen-source framework, developed by Charlton and colleagues, evaluates the performance of the beat detectors namedQPPG,MSPTDandABDamong others. We applied thePPG-beatsframework on two newly acquired datasets, one containing seven different types of cardiac arrhythmia in hospital settings, and another dataset including two cardiac arrhythmias in ambulatory settings.Main Results. In a clinical setting, theQPPGbeat detector performed best on atrial fibrillation (with a medianF1score of 94.4%), atrial flutter (95.2%), atrial tachycardia (87.0%), sinus rhythm (97.7%), ventricular tachycardia (83.9%) and was ranked 2nd for bigeminy (75.7%) behindABDdetector (76.1%). In an ambulatory setting, theMSPTDbeat detector performed best on normal sinus rhythm (94.6%), and theQPPGdetector on atrial fibrillation (91.6%) and bigeminy (80.0%).Significance. Overall, the PPG beat detectorsQPPG,MSPTDandABDconsistently achieved higher performances than other detectors. However, the detection of beats from wrist-PPG signals is compromised in presence of bigeminy or ventricular tachycardia.


Subject(s)
Atrial Fibrillation , Tachycardia, Ventricular , Humans , Heart Rate , Atrial Fibrillation/diagnosis , Photoplethysmography/methods , Benchmarking , Tachycardia, Ventricular/diagnosis , Algorithms , Electrocardiography/methods
7.
Front Cardiovasc Med ; 10: 1267800, 2023.
Article in English | MEDLINE | ID: mdl-37799779

ABSTRACT

Background: Stereotactic arrhythmia radioablation (STAR) is a potential new therapy for patients with refractory ventricular tachycardia (VT). The arrhythmogenic substrate (target) is synthesized from clinical and electro-anatomical information. This study was designed to evaluate the baseline interobserver variability in target delineation for STAR. Methods: Delineation software designed for research purposes was used. The study was split into three phases. Firstly, electrophysiologists delineated a well-defined structure in three patients (spinal canal). Secondly, observers delineated the VT-target in three patients based on case descriptions. To evaluate baseline performance, a basic workflow approach was used, no advanced techniques were allowed. Thirdly, observers delineated three predefined segments from the 17-segment model. Interobserver variability was evaluated by assessing volumes, variation in distance to the median volume expressed by the root-mean-square of the standard deviation (RMS-SD) over the target volume, and the Dice-coefficient. Results: Ten electrophysiologists completed the study. For the first phase interobserver variability was low as indicated by low variation in distance to the median volume (RMS-SD range: 0.02-0.02 cm) and high Dice-coefficients (mean: 0.97 ± 0.01). In the second phase distance to the median volume was large (RMS-SD range: 0.52-1.02 cm) and the Dice-coefficients low (mean: 0.40 ± 0.15). In the third phase, similar results were observed (RMS-SD range: 0.51-1.55 cm, Dice-coefficient mean: 0.31 ± 0.21). Conclusions: Interobserver variability is high for manual delineation of the VT-target and ventricular segments. This evaluation of the baseline observer variation shows that there is a need for methods and tools to improve variability and allows for future comparison of interventions aiming to reduce observer variation, for STAR but possibly also for catheter ablation.

8.
Radiother Oncol ; 189: 109949, 2023 12.
Article in English | MEDLINE | ID: mdl-37827279

ABSTRACT

BACKGROUND AND PURPOSE: In patients with recurrent ventricular tachycardia (VT), STereotactic Arrhythmia Radioablation (STAR) shows promising results. The STOPSTORM.eu consortium was established to investigate and harmonise STAR treatment in Europe. The primary goals of this benchmark study were to standardise contouring of organs at risk (OAR) for STAR, including detailed substructures of the heart, and accredit each participating centre. MATERIALS AND METHODS: Centres within the STOPSTORM.eu consortium were asked to delineate 31 OAR in three STAR cases. Delineation was reviewed by the consortium expert panel and after a dedicated workshop feedback and accreditation was provided to all participants. Further quantitative analysis was performed by calculating DICE similarity coefficients (DSC), median distance to agreement (MDA), and 95th percentile distance to agreement (HD95). RESULTS: Twenty centres participated in this study. Based on DSC, MDA and HD95, the delineations of well-known OAR in radiotherapy were similar, such as lungs (median DSC = 0.96, median MDA = 0.1 mm and median HD95 = 1.1 mm) and aorta (median DSC = 0.90, median MDA = 0.1 mm and median HD95 = 1.5 mm). Some centres did not include the gastro-oesophageal junction, leading to differences in stomach and oesophagus delineations. For cardiac substructures, such as chambers (median DSC = 0.83, median MDA = 0.2 mm and median HD95 = 0.5 mm), valves (median DSC = 0.16, median MDA = 4.6 mm and median HD95 = 16.0 mm), coronary arteries (median DSC = 0.4, median MDA = 0.7 mm and median HD95 = 8.3 mm) and the sinoatrial and atrioventricular nodes (median DSC = 0.29, median MDA = 4.4 mm and median HD95 = 11.4 mm), deviations between centres occurred more frequently. After the dedicated workshop all centres were accredited and contouring consensus guidelines for STAR were established. CONCLUSION: This STOPSTORM multi-centre critical structure contouring benchmark study showed high agreement for standard radiotherapy OAR. However, for cardiac substructures larger disagreement in contouring occurred, which may have significant impact on STAR treatment planning and dosimetry evaluation. To standardize OAR contouring, consensus guidelines for critical structure contouring in STAR were established.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Tachycardia, Ventricular , Humans , Radiotherapy Planning, Computer-Assisted/methods , Benchmarking , Heart , Coronary Vessels , Tachycardia, Ventricular/radiotherapy , Tachycardia, Ventricular/surgery
9.
J Clin Med ; 12(19)2023 Sep 29.
Article in English | MEDLINE | ID: mdl-37834932

ABSTRACT

Over the last few years, pacing of the conduction system (CSP) has emerged as the new standard pacing modality for bradycardia indications, allowing a more physiological ventricular activation compared to conventional right ventricular pacing. CSP has also emerged as an alternative modality to conventional biventricular pacing for the delivery of cardiac resynchronization therapy (CRT) in heart failure patients. However, if the initial clinical data seem to support this new physiological-based approach to CRT, the lack of large randomized studies confirming these preliminary results prevents CSP from being used routinely in clinical practice. Furthermore, concerns are still present regarding the long-term performance of pacing leads when employed for CSP, as well as their extractability. In this review article, we provide the state-of-the-art of CSP as an alternative to biventricular pacing for CRT delivery in heart failure patients. In particular, we describe the physiological concepts supporting this approach and we discuss the future perspectives of CSP in this context according to the implant techniques (His bundle pacing and left bundle branch area pacing) and the clinical data published so far.

10.
Radiother Oncol ; 189: 109910, 2023 12.
Article in English | MEDLINE | ID: mdl-37709052

ABSTRACT

BACKGROUND: Stereotactic arrhythmia radioablation (STAR) appears to be beneficial in selected patients with therapy-refractory ventricular tachycardia (VT). However, high-dose radiotherapy used for STAR-treatment may affect functioning of the patients' implantable cardioverter defibrillator (ICD) by direct effects of radiation on ICD components or cardiac tissue. Currently, the effect of STAR on ICD functioning remains unknown. METHODS: A retrospective pre-post multicenter study evaluating ICD functioning in the 12-month before and after STAR was performed. Patients with (non)ischemic cardiomyopathies with therapy-refractory VT and ICD who underwent STAR were included and the occurrence of ICD-related adverse events was collected. Evaluated ICD parameters included sensing, capture threshold and impedance. A linear mixed-effects model was used to investigate the association between STAR, radiotherapy dose and changes in lead parameters over time. RESULTS: In total, 43 patients (88% male) were included in this study. All patients had an ICD with an additional right atrial lead in 34 (79%) and a ventricular lead in 17 (40%) patients. Median ICD-generator dose was 0.1 Gy and lead tip dose ranged from 0-32 Gy. In one patient (2%), a reset occurred during treatment, but otherwise, STAR and radiotherapy dose were not associated with clinically relevant alterations in ICD leads parameters. CONCLUSIONS: STAR treatment did not result in major ICD malfunction. Only one radiotherapy related adverse event occurred during the study follow-up without patient harm. No clinically relevant alterations in ICD functioning were observed after STAR in any of the leads. With the reported doses STAR appears to be safe.


Subject(s)
Defibrillators, Implantable , Myocardial Ischemia , Tachycardia, Ventricular , Humans , Male , Female , Defibrillators, Implantable/adverse effects , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Retrospective Studies , Arrhythmias, Cardiac/etiology , Myocardial Ischemia/etiology , Treatment Outcome
11.
Europace ; 25(10)2023 Oct 05.
Article in English | MEDLINE | ID: mdl-37695314

ABSTRACT

AIMS: Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analysed recurrences in our patients after STAR. METHODS AND RESULTS: From 09.2017 to 01.2020, 20 patients (68 ± 8 y, LVEF 37 ± 15%) suffering from refractory VT were enrolled, 16/20 with a history of at least one electrical storm. Before STAR, an invasive electroanatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23 ± 2 Gy was delivered to the planning target volume (PTV). The median ablation volume was 26 mL (range 14-115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in the proximity of the treated substrate in nine cases, remote from the PTV in three cases and involved a larger substrate over ≥3 LV segments in two cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR. CONCLUSION: STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude.

12.
J Clin Med ; 12(16)2023 Aug 08.
Article in English | MEDLINE | ID: mdl-37629216

ABSTRACT

BACKGROUND: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. METHODS: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. RESULTS: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14-1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). CONCLUSIONS: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.

13.
Radiother Oncol ; 188: 109844, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37543057

ABSTRACT

AIM: To identify the optimal STereotactic Arrhythmia Radioablation (STAR) strategy for individual patients, cardiorespiratory motion of the target volume in combination with different treatment methodologies needs to be evaluated. However, an authoritative overview of the amount of cardiorespiratory motion in ventricular tachycardia (VT) patients is missing. METHODS: In this STOPSTORM consortium study, we performed a literature review to gain insight into cardiorespiratory motion of target volumes for STAR. Motion data and target volumes were extracted and summarized. RESULTS: Out of the 232 studies screened, 56 provided data on cardiorespiratory motion, of which 8 provided motion amplitudes in VT patients (n = 94) and 10 described (cardiac/cardiorespiratory) internal target volumes (ITVs) obtained in VT patients (n = 59). Average cardiac motion of target volumes was < 5 mm in all directions, with maximum values of 8.0, 5.2 and 6.5 mm in Superior-Inferior (SI), Left-Right (LR), Anterior-Posterior (AP) direction, respectively. Cardiorespiratory motion of cardiac (sub)structures showed average motion between 5-8 mm in the SI direction, whereas, LR and AP motions were comparable to the cardiac motion of the target volumes. Cardiorespiratory ITVs were on average 120-284% of the gross target volume. Healthy subjects showed average cardiorespiratory motion of 10-17 mm in SI and 2.4-7 mm in the AP direction. CONCLUSION: This review suggests that despite growing numbers of patients being treated, detailed data on cardiorespiratory motion for STAR is still limited. Moreover, data comparison between studies is difficult due to inconsistency in parameters reported. Cardiorespiratory motion is highly patient-specific even under motion-compensation techniques. Therefore, individual motion management strategies during imaging, planning, and treatment for STAR are highly recommended.

14.
Front Cardiovasc Med ; 10: 1213165, 2023.
Article in English | MEDLINE | ID: mdl-37547255

ABSTRACT

Background: Cardiac sarcoidosis is associated with heart failure, conduction abnormalities, and life-threatening arrhythmias including ventricular tachycardia (VT). Radiotherapy has been suggested as a treatment for extra-cardiac sarcoidosis in patients refractory to immunomodulatory treatment. Methods: The effectiveness and safety of low-dose whole-heart radiotherapy for therapy refractory cardiac sarcoidosis were evaluated in a pre- and post-intervention case report comparing the 54 months before and after treatment. Immunomodulatory low-dose whole-heart irradiation as sarcoidosis treatment consisted of a 2 × 2 Gy scheme. Additionally, high-dose single-fraction stereotactic arrhythmia radioablation of 1 × 20 Gy was applied to the pro-arrhythmic region to manage the ventricular tachycardia episodes. Cardiac sarcoidosis disease activity was measured by hypermetabolic areas on repeated fluorodeoxyglucose ([18F]FDG)-PET/computed tomography (CT) scans and by evaluating changes in ventricular tachycardia episodes before and after treatment. Results: One patient with therapy refractory progressive cardiac sarcoidosis and recurrent ventricular tachycardia was treated. The cardiac sarcoidosis disease activity showed a durable regression of inflammatory disease activity from 3 months onwards. The [18F]FDG-PET/CT scan at 54 months did not show any signs of active cardiac sarcoidosis, and a state of remission was achieved. The number of sustained VT episodes was reduced by 95%. We observed that the development of moderate aortic valve regurgitation was likely irradiation-related. No other irradiation-related adverse events occurred, and the left ventricular ejection fraction remained stable. Conclusion: We report here for the first time on the beneficial and lasting effects of combined immunomodulatory low-dose whole-heart radiotherapy and high-dose stereotactic arrhythmia radioablation in a patient with therapy refractory cardiac sarcoidosis and recurrent VT.

15.
J Am Heart Assoc ; 12(13): e028956, 2023 07 04.
Article in English | MEDLINE | ID: mdl-37345794

ABSTRACT

Background Data on the incidence of arrhythmias, associated cardiac interventions, and outcome in patients with dextro-transposition of the great arteries and atrial switch are scarce. Methods and Results In this multicenter analysis, we included adult patients with dextro-transposition of the great arteries and atrial switch regularly followed up at 3 Swiss tertiary care hospitals. The primary outcome was a composite of left ventricular assist device, heart transplantation, and death. The secondary outcome was occurrence of ventricular tachycardia, ventricular fibrillation, or sudden cardiac death. We identified 207 patients (34% women; median age at last follow-up, 35 years) with dextro-transposition of the great arteries and atrial switch. Arrhythmias occurred in 97 patients (47%) at a median age of 22 years. A pacemaker or an implantable cardioverter-defibrillator was implanted in 39 (19%) and 13 (6%) patients, respectively, and 33 (16%) patients underwent a total of 51 ablation procedures to target 60 intra-atrial re-entry tachycardias, 4 atrioventricular nodal re-entry tachycardias, and 1 atrial fibrillation. The primary outcome occurred in 21 patients (10%), and the secondary outcome occurred in 18 patients (9%); both were more common in patients with concomitant ventricular septum defect than in those without (hazard ratio [HR], 3.06 [95% CI, 1.29-7.27], P=0.011; and HR, 3.62 [95% CI, 1.43-9.18], P=0.007, respectively). Conclusions In patients with dextro-transposition of the great arteries and atrial switch reaching adulthood, arrhythmias occur in almost half of patients, and associated rhythm interventions are frequent. One-tenth of those patients do not survive until the age of 35 years free from left ventricular assist device or heart transplantation, and the outcome is worse in patients with concomitant ventricular septum defect.


Subject(s)
Atrial Fibrillation , Tachycardia, Supraventricular , Transposition of Great Vessels , Adult , Humans , Female , Young Adult , Male , Atrial Fibrillation/complications , Switzerland/epidemiology , Tachycardia, Supraventricular/complications , Arteries , Follow-Up Studies , Treatment Outcome
19.
Rev Med Suisse ; 19(N° 809-10): 16-24, 2023 Jan 18.
Article in French | MEDLINE | ID: mdl-36660831

ABSTRACT

The year of 2022 was marked by many novelties in the fields of interventional cardiology, heart failure, electrophysiology, cardiac imaging, and congenital heart disease. These advances will certainly change our daily practice, on top of improving the diagnosis and treatment of many heart conditions. In addition, the European Society of Cardiology has updated its guidelines on pulmonary hypertension, ventricular arrhythmias and sudden death, cardiovascular assessment of patients undergoing non-cardiac surgery. The members of the Cardiology division of Lausanne University Hospital (CHUV) here present the publications which they considered to be the most important of the past year.


L'année 2022 a été marquée par de nombreuses nouveautés dans les domaines de la cardiologie interventionnelle, de l'insuffisance cardiaque, de l'électrophysiologie, de l'imagerie cardiaque et des cardiopathies congénitales. Ces progrès vont certainement faire évoluer notre pratique quotidienne, en plus d'améliorer le diagnostic et le traitement de nombreuses cardiopathies. Par ailleurs, la Société européenne de cardiologie a mis à jour ses recommandations portant sur l'hypertension pulmonaire, les arythmies ventriculaires et la mort subite ainsi que le bilan cardiologique avant une chirurgie non cardiaque. Les membres du Service de cardiologie du CHUV vous présentent ici les travaux qui leur ont semblé être les plus importants de l'année écoulée.


Subject(s)
Cardiology , Heart Defects, Congenital , Heart Failure , Humans , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Heart Defects, Congenital/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...