Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Electrocardiol ; 85: 75-77, 2024.
Article in English | MEDLINE | ID: mdl-38924804

ABSTRACT

The ECG of a patient during sinus rhythm shows preexcited QRS pattern, with rS pattern in lead V1, transition in lead V2, and positive inferior leads. Following the stepwise algorithms, the location of accessory pathway (AP) was identified at anteroseptal region. However, the precordial transition in lead V2 indicates mid-septal or posteroseptal AP. The mismatch suggested multiple APs and 5 APs were identified by electrophysiologic study. This case highlights the importance of detailed analysis of ECG in order to achieve adequate ablation.


Subject(s)
Accessory Atrioventricular Bundle , Electrocardiography , Humans , Accessory Atrioventricular Bundle/physiopathology , Accessory Atrioventricular Bundle/surgery , Male , Catheter Ablation , Adult , Female , Wolff-Parkinson-White Syndrome/physiopathology , Wolff-Parkinson-White Syndrome/surgery , Wolff-Parkinson-White Syndrome/diagnosis , Diagnosis, Differential
2.
J Cardiovasc Electrophysiol ; 35(3): 469-477, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38282257

ABSTRACT

INTRODUCTION: The optimized ablation index (AI) value for catheter ablation of atrial fibrillation (AF) remains to be defined. We aimed to compare the efficacy and safety of CLOSE protocol and lower AI protocol in paroxysmal AF. METHODS AND RESULTS: Patients with symptomatic, drug-resistant paroxysmal AF for first ablation were prospectively enrolled from September 2020 to January 2022. The patients were randomly divided into CLOSE group (AI ≥ 550 for anterior/roof segments and ≥400 for posterior/inferior segments) and lower AI group (AI ≥ 450 for anterior/roof segments and ≥350 for posterior/inferior segments). First-pass isolation, acute pulmonary vein (PV) reconnections, 1-year arrhythmia recurrence, and major complications were assessed. Of the 270 enrolled patients, 238 completed 1-year follow-up (118 in CLOSE group and 120 in lower AI group). First-pass isolation in left PVs was higher in CLOSE group (71.2% vs. 53.3%, p = .005). Acute PV reconnections were comparable between groups (9.3% vs. 14.2%, p = .246). At 1 year, 86.4% in CLOSE group versus 81.7% in lower AI group were free from atrial arrhythmia (log rank p = .334). The proportion difference was -4.8% (95% CI: -14.1% to 4.6%), and p = .475 for noninferiority. Stroke occurred in four patients of lower AI group, and no cardiac tamponade, atrioesophageal fistula, major bleeding or death occurred post procedure. CONCLUSION: For patients with paroxysmal AF and treated by AI-guided PV ablation, lower AI is not noninferior to CLOSE protocol.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Pulmonary Veins/surgery , Treatment Outcome , Clinical Protocols
SELECTION OF CITATIONS
SEARCH DETAIL