Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 348
Filter
1.
Int J Cardiol ; : 132320, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38964549

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is common in patients with heart failure (HF). Real-world data about long-term outcomes and rhythm control interventions use in AF patients with and without HF remain scarce. METHODS: AF patients from two prospective, multicentre studies were classified based on the HF status at baseline into: HF with preserved ejection fraction (HFpEF), HF with reduced or mildly reduced ejection fraction (HFrEF/HFmrEF), and no HF. The prespecified primary outcome was risk of HF hospitalisation. Other outcomes of interest included mortality, cardiovascular events, AF progression, and quality of life. RESULTS: A total of 1265 patients with AF were analysed (mean age 69.6 years, women 27.4%) with a median follow-up of 5.98 years. Patients with HFpEF (n = 126) had a 2.69-fold and patients with HFrEF/HFmrEF (n = 308) had a 2.12-fold increased risk of HF hospitalisation compared to patients without HF (n = 831, p < 0.001). Similar results applied for all-cause and cardiovascular mortality. The risk for AF progression was higher for patients with HFpEF and HFrEF/HFmrEF (6.30 and 6.79 per 100 patient-years, respectively) compared to patients without HF (4.20). The use of rhythm control strategies during follow-up was least in the HFpEF population (4.56 per 100 patient-years) compared to 7.74 in HFrEF/HFmrEF and 8.03 in patients with no HF. With regards to quality of life over time, this was worst among HFpEF patients. CONCLUSIONS: The presence of HFpEF among patients with AF carried a high risk of HF hospitalisations and AF progression, and worse quality of life. Rhythm control interventions were rarely offered to HFpEF patients. These results uncover an unmet need for enhanced therapeutic interventions in patients with AF and HFpEF.

2.
Article in English | MEDLINE | ID: mdl-38869506

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: To assess the outcomes of pulsed-field ablation (PFA) in HF. METHODS: MANIFEST-PF is a multicenter patient-level registry of consecutive patients undergoing PFA for paroxysmal (PAF) or persistent AF (PerAF). In this sub-study, patients were stratified as: no history of HF (no-HF), HF with preserved EF (HFPEF; LVEF≥50%) or HF with reduced/mildly-reduced EF (HFMR/REF; LVEF<50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30s and major adverse events (MAEs), respectively. RESULTS: Of the 1,381 patients, 85% (n=1,174) were no-HF, 6.2% (n=87) were HFPEF, and 8.6% (n=120) were HFMR/REF. No-HF patients had less PerAF than patients with HF (p<0.001), with no difference between HF subtypes (p=1.00). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF than with HFPEF or HFMR/REF (79.9%, 71.3%, 67.5%, p<0.001), but similar between HFMR/REF and HFPEF (p=0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFPEF vs HFMR/REF for those with PAF (82.8%/82.4%/71.7%, p=0.09) and PerAF (73.3%, 64.2%, and 64.9%, p=0.14.MAE rates were similar between the no-HF, HFPEF and HFMR/REF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSION: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

3.
Article in English | MEDLINE | ID: mdl-38864809

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively. RESULTS: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P = >0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSIONS: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.

4.
Heart Rhythm O2 ; 5(5): 257-265, 2024 May.
Article in English | MEDLINE | ID: mdl-38840763

ABSTRACT

Background: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology. Its potential value for repeat procedures after unsuccessful thermal ablation for atrial fibrillation has not been assessed. Objective: The purpose of this study was to summarize our initial experience with patients undergoing repeat procedures using PFA. Methods: Consecutive patients with arrhythmia recurrences after a prior thermal ablation undergoing a repeat procedure using a multipolar PFA catheter from May 2021 and December 2022 were included. After 3-dimensional electroanatomic mapping, reconnected pulmonary veins (PVs) were reisolated and veins with only ostial isolation wither ablated to widen antral PV isolation. Posterior wall ablation was performed if all PVs were durably isolated or in case of low-voltage areas on the posterior wall at the discretion of the operator. Patients underwent follow-up with 7-day Holter electrocardiography after 3, 6, and 12 months. Results: A total of 186 patients undergoing a repeat procedure using PFA were included. The median number of previous ablations was 1 (range 1-6). The prior ablation modality was radiofrequency in 129 patients (69.4%), cryoballoon in 51 (27.4%), and epicardial ablation in 6 (3.2%). At the beginning of the procedure, 258 of 744 PVs (35%) showed reconnections. Additional antral ablations were applied in 236 of 486 still isolated veins (49%). Posterior wall ablation was added in 125 patients (67%). Major complications occurred in 1 patient (transient ischemic attack 0.5%). Freedom from arrhythmia recurrence in Kaplan-Meier-analysis was 78% after 6 months and 54% after 12 months. Conclusion: PFA is a versatile and safe option for repeat procedures after failed prior thermal ablation.

5.
Article in English | MEDLINE | ID: mdl-38842971

ABSTRACT

BACKGROUND: There is limited information on the mode of arrhythmia initiation in idiopathic ventricular fibrillation (IVF). A non-pause-dependent mechanism has been suggested to be the rule. OBJECTIVES: The aim of this study was to assess the mode and characteristics of initiation of polymorphic ventricular tachycardia (PVT) in patients with short or long-coupled PVT/IVF included in THESIS (THerapy Efficacy in Short or long-coupled idiopathic ventricular fibrillation: an International Survey), a multicenter study involving 287 IVF patients treated with drugs or radiofrequency ablation. METHODS: We reviewed the initiation of 410 episodes of ≥1 PVT triplet in 180 patients (58.3% females; age 39.6 ± 13.6 years) with IVF. The incidence of pause-dependency arrhythmia initiation (prolongation by >20 ms of the preceding cycle length) was assessed. RESULTS: Most arrhythmias (n = 295; 72%) occurred during baseline supraventricular rhythm without ambient premature ventricular complexes (PVCs), whereas 106 (25.9%) occurred during baseline rhythm including PVCs. Nine (2.2%) arrhythmias occurred during atrial/ventricular pacing and were excluded from further analysis. Mode of PVT initiation was pause-dependent in 45 (15.6%) and 64 (60.4%) of instances in the first and second settings, respectively, for a total of 109 of 401 (27.2%). More than one type of pause-dependent and/or non-pause-dependent initiation (mean: 2.6) occurred in 94.4% of patients with ≥4 events. Coupling intervals of initiating PVCs were <350 ms, 350-500 ms, and >500 ms in 76.6%, 20.72%, and 2.7% of arrhythmia initiations, respectively. CONCLUSIONS: Pause-dependent initiation occurred in more than a quarter of arrhythmic episodes in IVF patients. PVCs having long (between 350 and 500 ms) and very long (>500 ms) coupling intervals were observed at the initiation of nearly a quarter of PVT episodes.

6.
Europace ; 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38917059

ABSTRACT

BACKGROUND AND AIMS: Atrial fibrillation (AF) ablation and left atrial appendage occlusion (LAAO) are increasingly performed as individual procedures. Pulsed field ablation (PFA) has significantly reduced procedure duration and may be advantageous for the combined approach. METHODS: We have launched a program for simultaneous AF ablation using PFA and LAAO for patients qualifying for both treatments and excluding those with complex anatomy. We compare procedure duration and fluoroscopy time against individual procedures (either AF ablation or LAAO alone), all performed by the same operators and using consistent technologies. RESULTS: We performed the combined procedure in 10 patients (50% male; median age 70 years) and excluded two patients (17%) because of complex LAA anatomy. No death, stroke or major bleeding, including pericardial effusion, occurred. For single procedure comparison, 207 AF ablation procedures and 61 LAAO procedures were available. Total median procedure duration was 79 minutes (range 60; 125) for the combined procedure, 71 minutes (25; 241) for individual AF ablation (51 minutes without and 78 minutes with 3D electroanatomic mapping) and 47 minutes (15; 162) for individual LAAO. Respective fluoroscopy times were 21 (15; 26), 15 (5; 44) and 10 (3; 50) minutes. For the combined procedure, femoral vein access to last PFA application lasted 49 minutes (34; 93) and LAAO added 20 minutes (15; 37). CONCLUSION: Simultaneous PFA-based AF ablation and LAAO in carefully selected patients is feasible, safe, and can be executed within a short overall procedure duration.

7.
Heart Rhythm ; 2024 May 16.
Article in English | MEDLINE | ID: mdl-38762133

ABSTRACT

BACKGROUND: Stroke remains one of the most serious complications in atrial fibrillation (AF) patients and has been linked to disturbances of the autonomic nervous system. OBJECTIVE: The purpose of this study was to test the hypothesis that impaired cardiac autonomic function might be associated with an enhanced stroke risk in AF patients. METHODS: A total of 1922 AF patients who were in either sinus rhythm (SR group; n = 1121) or AF (AF group; n = 801) on a 5-minute resting electrocardiographic (ECG) recording were enrolled in the study. Heart rate variability triangular index (HRVI), standard deviation of normal-to-normal intervals, root mean square root of successive differences of normal-to-normal intervals, mean heart rate, 5-minute total power, and power in the high-frequency, low-frequency, and very-low-frequency ranges were calculated. Cox regression models were constructed to examine the association of heart rate variability (HRV) parameters with the composite endpoint of stroke or systemic embolism. RESULTS: Mean age was 71 ± 8 years in the SR group and 75 ± 8 years in the AF group. Thirty-seven patients in the SR group (3.4%) and 60 patients in the AF group (8.0%) experienced a stroke or systemic embolism during follow-up of 5 years. In patients with SR, HRVI <15 was the strongest HRV parameter to be associated with stroke or systemic embolism (hazard ratio 3.04; 95% confidence interval 1.3-7.0; P = .009) after adjustment for multiple confounders. In the AF group, no HRV parameter was found to be associated with the composite endpoint. CONCLUSION: HRVI measured during SR on a single 5-minute ECG recording is independently associated with stroke or systemic embolism in AF patients. HRV analysis in SR may help to improve risk stratification in AF patients.

8.
Article in English | MEDLINE | ID: mdl-38819347

ABSTRACT

BACKGROUND: Catheter ablation for atrial fibrillation (AF) including pulmonary vein isolation and possibly further substrate ablation is the most common electrophysiological procedure. Severe complications are uncommon, but their detailed assessment in a large worldwide cohort is lacking. OBJECTIVES: The aim of this study was to determine the incidence of periprocedural severe complications and to provide a detailed characterization of the diagnostic evaluation and management of these complications in patients undergoing AF ablation. METHODS: Individual patient data were collected from 23 centers worldwide. Limited data were collected for all patients who underwent catheter ablation, and an expanded series of data points were collected for patients who experienced severe complications during periprocedural follow-up. Incidence, predictors, patient characteristics, management details, and overall outcomes of patients who experienced ablation-related complications were investigated. RESULTS: Data were collected from 23 participating centers at which 33,879 procedures were performed (median age 63 years, 30% women, 71% radiofrequency ablations). The incidence of severe complications (n = 271) was low (tamponade 6.8‰, stroke 0.97‰, cardiac arrest 0.41‰, esophageal fistula 0.21‰, and death 0.21‰). Age, female sex, a dilated left atrium, procedure duration, and the use of radiofrequency energy were independently associated with the composite endpoint of all severe complications. Among patients experiencing tamponade, 13% required cardiac surgery. Ninety-three percent of patients with complications were discharged directly home after a median length of stay of 5 days (Q1-Q3: 3-7 days). CONCLUSIONS: This large worldwide collaborative study highlighted that tamponade, stroke, cardiac arrest, esophageal fistula, and death are rare after AF ablation. Older age, female sex, procedure duration, a dilated left atrium, and the use of radiofrequency energy were associated with severe complications in this multinational cohort. One in 8 patients with tamponade required cardiac surgery.

10.
Article in English | MEDLINE | ID: mdl-38752963

ABSTRACT

BACKGROUND: Pulmonary vein isolation is an effective treatment for atrial fibrillation (AF). Cryoballoon ablation using the Arctic Front cryoballoon (Medtronic) was found to be superior to antiarrhythmic drug treatment. Recently, a novel cryoballoon system was introduced (PolarX, Boston Scientific). OBJECTIVES: The purpose of this study was to compare the efficacy and safety of the 2 cryoballoons in a randomized controlled trial. METHODS: Patients with symptomatic paroxysmal AF were enrolled in 2 centers and randomized 1:1 to pulmonary vein isolation using the PolarX or the Arctic Front cryoballoon. All patients received an implantable cardiac monitor. The primary endpoint was first recurrence of atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia [AT]) between days 91 and 365. Procedural safety was assessed by a composite of tamponade, phrenic nerve palsy lasting >24 hours, vascular complications, stroke/transient ischemic attack, atrioesophageal fistula or death up to 30 days. RESULTS: A total of 201 patients were enrolled. At 1 year, recurrence of atrial tachyarrhythmia had occurred in 41 of 99 patients (41.6%) assigned to the PolarX group and in 48 of 102 patients (47.1%) assigned to the Arctic Front group (HR: 0.85 [95% CI: 0.56-1.30]; P = 0.03 for noninferiority; P = 0.46 for superiority). The safety endpoint occurred in 5 patients (5%) in the PolarX group (n = 5 phrenic nerve palsies lasting >24 hours), whereas no safety endpoints occurred in the Arctic Front group (P = 0.03). CONCLUSIONS: In this randomized controlled trial using implantable cardiac monitors for continuous rhythm monitoring, the novel PolarX cryoballoon was noninferior compared with the Arctic Front cryoballoon regarding efficacy. However, the PolarX balloon resulted in significantly more phrenic nerve palsies. (Comparison of PolarX and the Arctic Front Cryoballoons for PVI in Patients With Symptomatic Paroxysmal AF [COMPARE-CRYO]; NCT04704986).

11.
Heart Rhythm ; 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38597857

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.

12.
JACC Clin Electrophysiol ; 10(6): 1090-1100, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38639700

ABSTRACT

BACKGROUND: Recurrence of paroxysmal atrial fibrillation (AF) following pulmonary vein isolation (PVI) is presumably caused by pulmonary vein (PV) reconnections. However, there is little data available on the durability of PVI and incidence of arrhythmia recurrence in patients with persistent AF. OBJECTIVES: The purpose of this study was to evaluate the lesion durability by means of an a priori planned remapping procedure in patients with persistent AF undergoing CLOSE-guided PVI. METHODS: In a prospective study, we included patients with symptomatic, persistent AF undergoing CLOSE-guided radiofrequency ablation. Irrespective of AF recurrence, a redo procedure was mandated 6 months following the index procedure to evaluate PV reconnections. The outcome of AF ablation was based on clinical recurrence and 7-day Holter electrocardiogram 3 and 6 months after the index procedure and 3, 6, and 12 months after the redo procedure. RESULTS: Of 30 patients included, 26 (81% men; median age 68 years) underwent the planned remapping study a median of 6 months after the index procedure, whereas 4 patients without recurrence refused a repeat procedure. In total, 78 of 102 (76%) PVs showed durable isolation and 15 patients (58%) presented complete isolation of all PVs. Beyond the blanking period, 6 of 26 patients (23%) had arrhythmia recurrence before the redo procedure. Recurrence had occurred in 33% of patients with complete isolation of all veins and in 9% of patients with PV reconnections (P = 0.197). After re-PVI in patients with PV reconnections and additional ablation in patients with recurrence but durable PVI, 17 of 26 patients (65%) were free of arrhythmia after 12 months. CONCLUSIONS: In patients with persistent AF, CLOSE-guided PVI resulted in durable rate of PVI on a per-vein and per-patient level of 76% and 58%, respectively. Arrhythmia recurrence was numerically higher in patients with durable PVI compared with patients without.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Recurrence , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Pulmonary Veins/surgery , Male , Female , Prospective Studies , Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Middle Aged , Treatment Outcome , Electrocardiography, Ambulatory , Reoperation/statistics & numerical data
13.
Pacing Clin Electrophysiol ; 47(6): 853-861, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38655610

ABSTRACT

AIMS: Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome. METHODS: From our prospective PM and ICD implantation registry, all patients who underwent PM and/or ICD implantations at our center were analyzed. Patient characteristics and outcomes of PM patients with subsequent ICD upgrade were compared to age- and sex-matched patients with de novo ICD implantation, and to PM patients without subsequent upgrade. RESULTS: Of 1'301 ICD implantations, 60 (5%) were upgraded from PMs. Median time from PM implantation to ICD upgrade was 2.6 years (IQR 1.3-5.4). Of 2'195 PM patients, 28 patients underwent subsequent ICD upgrades, corresponding to an estimated annual incidence of an ICD upgrade of at least 0.33%. Lower LVEF (p = .05) and male sex (p = .038) were independent predictors for ICD upgrade. Survival without death, transplant and LVAD implantation were worse both for upgraded ICD patients compared to matched patients with de novo ICD implantation (p = .05), as well as for PM patients with subsequent upgrade compared to matched PM patients not requiring an upgrade (p = .036). CONCLUSIONS: One of 20 ICD implantations are upgrade of patients with a PM. At least one of 30 PM patients will require an ICD upgrade in the following 10 years. Predictors for ICD upgrade are male sex and lower LVEF at PM implantation. Upgraded patients have worse outcomes.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Humans , Male , Female , Aged , Treatment Outcome , Prospective Studies , Registries , Middle Aged , Risk Factors , Survival Rate
14.
Heart Rhythm ; 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38614191

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA. METHODS: Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included. Patients underwent 7-day Holter electrocardiography at 3, 6, and 12 months postablation. The primary outcome was recurrence of any atrial arrhythmia after a 90-day blanking period. Safety outcomes included the composite of in-hospital major adverse events. RESULTS: A total of 533 patients with persistent AF underwent PVI using PFA (n = 214, 39%), CBA (n = 190, 36%), or RFA (n = 129, 24%). Procedures with PFA guided by fluoroscopy were shorter than those with CBA (median 60 minutes; interquartile range [IQR] 53-80 minutes vs 84 minutes; IQR 68-101 minutes; P ≤ .001), and procedures with PFA in combination with 3-dimensional electroanatomic mapping were shorter than those with RFA (median 101 minutes; IQR 85-126 minutes vs 171 minutes; IQR 141-204 minutes; P < .001). Acute safety events occurred in 2.3%, 2.6%, and 0.8% in the PFA, CBA, and RFA groups, respectively (P = .545). The 1-year confounder-adjusted estimate for freedom from atrial arrhythmias was 62.1% for CBA, 55.3% for PFA, and 48.3% for RFA (CBA vs PFA: P = .79; CBA vs RFA: P = .009; PFA vs RFA: P = .010). CONCLUSION: In patients with persistent AF undergoing first PVI, 1-year confounder-adjusted outcomes are better with PFA and CBA than with RFA.

15.
Article in English | MEDLINE | ID: mdl-38609733

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

16.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38597211

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Female , Humans , Middle Aged , Male , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Pulmonary Veins/surgery , Retrospective Studies , Treatment Outcome , Heart Atria/diagnostic imaging , Heart Atria/surgery , Phenotype , Recurrence , Catheter Ablation/adverse effects , Catheter Ablation/methods
17.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
18.
Article in English | MEDLINE | ID: mdl-38630571

ABSTRACT

The first commercial dual-chamber leadless pacemaker (LLPM) was introduced recently. The system combines two separate implants situated in the right atrium and the right ventricle of the heart. Implant synchronization is accomplished with conductive intracardiac communication (CIC) using the myocardium and blood as transmission channel. Successful implant synchronization of this dual-chamber LLPM has been demonstrated. However, the continuously active synchronization transceivers, consuming about 800 nA, cause a 25-45% reduction in the projected device longevity. This work proposes an alternative strategy for power-optimized LLPM synchronization, which is based on synchronous duty-cycling of the transceivers and direct-digital CIC (DD-CIC). In line with this strategy, a novel low-power DD-CIC receiver for short-packet communication based on Manchester-encoded data and with fast startup time is presented. The circuit was fabricated in 180 nm CMOS technology and analyzed with respect to sensitivity, current consumption and startup time under highly duty-cycled operation. The receiver achieves a sensitivity of 81.6±7.4 µV at a data rate of 100 kb/s, with an active current consumption of 39.1±0.6 µA and a startup time below 250 µs. Operating the receiver as specified by the proposed LLPM synchronization strategy reduces the current consumption to a measured average value of 73 nA. In conclusion, this work suggests synchronous duty-cycling for CIC-based implant synchronization as a promising concept to severely reduce the current consumption of contemporary dual-chamber LLPMs. Consequently, device longevity may be increased significantly, potentially reducing the frequency of costly and complication-prone re-interventions.

19.
JAMA Cardiol ; 9(5): 480-485, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38568602

ABSTRACT

Importance: Arterial hypoxemia, electrolyte imbalances, and periodic breathing increase the vulnerability to cardiac arrhythmia at altitude. Objective: To explore the incidence of tachyarrhythmias and bradyarrhythmias in healthy individuals at high altitudes. Design, Setting, and Participants: This prospective cohort study involved healthy individuals at altitude (8849 m) on Mount Everest, Nepal. Recruitment occurred from January 25 to May 9, 2023, and data analysis took place from June to July 2023. Exposure: All study participants underwent 12-lead electrocardiogram, transthoracic echocardiography, and exercise stress testing before and ambulatory rhythm recording both before and during the expedition. Main Outcome: The incidence of a composite of supraventricular (>30 seconds) and ventricular (>3 beats) tachyarrhythmia and bradyarrhythmia (sinoatrial arrest, second- or third-degree atrioventricular block). Results: Of the 41 individuals recruited, 100% were male, and the mean (SD) age was 33.6 (8.9) years. On baseline investigations, there were no signs of exertional ischemia, wall motion abnormality, or cardiac arrhythmia in any of the participants. Among 34 individuals reaching basecamp at 5300 m, 32 participants climbed to 7900 m or higher, and 14 reached the summit of Mount Everest. A total of 45 primary end point-relevant events were recorded in 13 individuals (38.2%). Forty-three bradyarrhythmic events were documented in 13 individuals (38.2%) and 2 ventricular tachycardias in 2 individuals (5.9%). Nine arrhythmias (20%) in 5 participants occurred when climbers were using supplemental bottled oxygen, whereas 36 events (80%) in 11 participants occurred at lower altitudes when no supplemental bottled oxygen was used. The proportion of individuals with arrhythmia remained stable across levels of increasing altitude, while event rates per 24 hours numerically increased between 5300 m (0.16 per 24 hours) and 7300 m (0.37 per 24 hours) before decreasing again at higher altitudes, where supplemental oxygen was used. None of the study participants reported dizziness or syncope. Conclusion and Relevance: In this study, more than 1 in 3 healthy individuals experienced cardiac arrhythmia during the climb of Mount Everest, thereby confirming the association between exposure to high altitude and incidence of cardiac arrhythmia. Future studies should explore the potential implications of these rhythm disturbances.


Subject(s)
Altitude , Arrhythmias, Cardiac , Electrocardiography , Mountaineering , Humans , Male , Adult , Prospective Studies , Nepal/epidemiology , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Female , Incidence , Exercise Test , Bradycardia/epidemiology , Bradycardia/physiopathology , Bradycardia/etiology , Echocardiography
20.
Article in English | MEDLINE | ID: mdl-38478165

ABSTRACT

BACKGROUND: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported. In this study, we report the extended outcomes of the CRAFT study to 36 months. METHODS: Patients with typical AFL and no evidence of AF were randomised 1:1 to cryoballoon PVI or radiofrequency CTI. All patients received an implantable loop recorder (ILR) for continuous cardiac rhythm monitoring. The primary outcome was time-to-symptomatic arrhythmia recurrence > 30 s. Secondary outcomes included time-to-first-AF episode ≥ 2 min. The composite safety outcome included death, stroke and procedural complications. RESULTS: A total of 113 patients were randomised to cryoballoon PVI (n = 54) or radiofrequency CTI ablation (n = 59). Ninety-one patients reconsented for extended follow-up beyond 12 months. There was no difference in the primary outcome between arms, with the primary outcome occurring in 12 PVI vs 11 CTI patients (HR 0.97; 95% CI 0.43-2.20; p = 0.994). AF ≥ 2 min was significantly less frequent in the PVI arm, affecting 26 PVI vs 36 CTI patients (HR 0.48; 95% CI 0.29-0.79; p = 0.004). The composite safety outcome occurred in 5 PVI and 6 CTI patients (p = 0.755). CONCLUSION: Cryoballoon PVI shows similar efficacy to radiofrequency CTI ablation in reducing symptomatic arrhythmia recurrence in patients presenting with isolated typical AFL but significantly reduces the occurrence of subsequent AF.

SELECTION OF CITATIONS
SEARCH DETAIL
...