Catheter Cardiovasc Interv ; 55(2): 133-9, 2002 Feb.
Article in English | MEDLINE | ID: mdl-11835634

ABSTRACT

The objective of this study was to evaluate the early angiographic outcome in the first human subjects who underwent intracoronary atherectomy and thrombectomy using the X-Sizer helical cutting and aspiration system. Percutaneous coronary interventions in patients with thrombo-occlusive disease or friable degenerative saphenous vein grafts are associated with considerable periprocedural morbidity and mortality, predominantly related to microscopic distal embolization. X-Sizer catheter system is a novel atherectomy and thrombectomy device that consists of a helix cutter connected to a handheld motor drive unit and a vacuum collection chamber for aspiration of excised atheroma, thrombus, and debris. Quantitative coronary angiography was obtained in 14 patients before and after X-Sizer extraction atherectomy with adjunctive balloon angioplasty and stenting. Thirteen native coronary arteries and one saphenous vein graft were treated. Mean preprocedural reference vessel diameter was 3.06 +/- 0.66 mm. There were 71.4% AHA/ACC type B2 and C lesions. Preprocedural thrombus was present in nine patients and total occlusion in 64% of cases. Minimal luminal diameter was increased from 0.29 +/- 0.47 mm to 1.32 +/- 0.64 mm, a gain of 1.04 +/- 0.69 mm after atherectomy. Final total gain was 1.47 +/- 0.61 mm. Mean diameter stenosis was reduced from 89.3% to a final residual stenosis of 14.4%. Postatherectomy distal embolization occurred in one patient who had heavy preprocedural thrombus burden. No episodes of perforation, distal coronary spasm, abrupt closure, or slow/no-reflow occurred. The angiographic analysis of the first cohort of human subjects suggests that X-Sizer helical atherectomy is a feasible method of removing occlusive tissue or thrombus in coronary artery disease with a low angiographic complication rate. A large-scale randomized phase II clinical trial is underway to determine the ultimate safety and efficacy of this device in thrombo-occlusive native coronary arteries and saphenous vein grafts.


Subject(s)
Atherectomy, Coronary/instrumentation , Catheters, Indwelling , Coronary Angiography , Thrombectomy/instrumentation , Angioplasty, Balloon, Coronary/instrumentation , Blood Vessel Prosthesis , Coronary Angiography/adverse effects , Coronary Stenosis/complications , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/surgery , Coronary Thrombosis/complications , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/therapy , Equipment Design , Europe/epidemiology , Humans , Incidence , Recurrence , Reoperation , Saphenous Vein/diagnostic imaging , Saphenous Vein/transplantation , South America/epidemiology , Stents , Treatment Outcome , Videotape Recording
SELECTION OF CITATIONS
SEARCH DETAIL