Water Res X ; 22: 100215, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38831972

ABSTRACT

A growing number of cities and regions are promoting or mandating on-site treatment and reuse of wastewater, which has resulted in the implementation of several thousand on-site water reuse systems on a global scale. However, there is only limited information on the (microbial) water quality from implemented systems. The focus of this study was on two best-in-class on-site water reuse systems in Bengaluru, India, which typically met the local water quality requirements during monthly compliance testing. This study aimed to (i) assess the microbial quality of the reclaimed water at a high temporal resolution (daily or every 15 min), and (ii) explore whether measurements from commercially available sensors can be used to improve the operation of such systems. The monitoring campaign revealed high variations in microbial water quality, even in these best-in-class systems, rendering the water inadequate for the intended reuse applications (toilet flushing and landscape irrigation). These variations were attributed to two key factors: (1) the low frequency of chlorination, and (2) fluctuations of the chlorine demand of the water, in particular of ammonium concentrations. Such fluctuations are likely inherent to on-site systems, which rely on a low level of process control. The monitoring campaign showed that the microbial water quality was most closely related to oxidation-reduction potential (ORP) and free chlorine sensors. Due to its relatively low cost and low need for maintenance, the ORP emerges as a compelling candidate for automating the chlorination to effectively manage variations in chlorine demand and ensure safe water reuse. Overall, this study underscores the necessity of integrating treatment trains, operation, and monitoring for safe on-site water reuse.

2.
Water Res ; 240: 120075, 2023 Jul 15.
Article in English | MEDLINE | ID: mdl-37263119

ABSTRACT

Widespread implementation of on-site water reuse is hindered by the limited availability of monitoring approaches that ensure microbial quality during operation. In this study, we developed a methodology for monitoring microbial water quality in on-site water reuse systems using inexpensive and commercially available online sensors. An extensive dataset containing sensor and microbial water quality data for six of the most critical types of disruptions in membrane bioreactors with chlorination was collected. We then tested the ability of three typological machine learning algorithms - logistic regression, support-vector machine, and random forest - to predict the microbial water quality as "safe" or "unsafe" for reuse. The main criteria for model optimization was to ensure a low false positive rate (FPR) - the percentage of safe predictions when the actual condition is unsafe - which is essential to protect users health. This resulted in enforcing a fixed FPR ≤ 2%. Maximizing the true positive rate (TPR) - the percentage of safe predictions when the actual condition is safe - was given second priority. Our results show that logistic-regression-based models using only two out of the six sensors (free chlorine and oxidation-reduction potential) achieved the highest TPR. Including sensor slopes as engineered features allowed to reach similar TPRs using only one sensor instead of two. Analysis of the occurrence of false predictions showed that these were mostly early alarms, a characteristic that could be regarded as an asset in alarm management. In conclusion, the simplest algorithm in combination with only one or two sensors performed best at predicting the microbial water quality. This result provides useful insights for water quality modeling or for applications where small datasets are a common challenge and a general advantage might be gained by using simpler models that reduce the risk of overfitting, allow better interpretability, and require less computational power.


Subject(s)
Algorithms , Water Quality , Bioreactors
3.
Sci Total Environ ; 895: 165042, 2023 Oct 15.
Article in English | MEDLINE | ID: mdl-37355129

ABSTRACT

In dealing with water pollution and freshwater scarcity, on-site treatment and reuse of domestic wastewater has shown to be a promising solution. To increase on-site wastewater treatment and reuse, some cities, among them Bengaluru in India, have mandated the installation and use of the necessary technology in certain building types. However, even with a mandate, a successful and sustainable implementation of the technology, including reliable operation, monitoring, and maintenance, depends on the acceptance (i.e. positive valuation) of the technology and its use by the (prospective) users. Literature on technology acceptance indicates perceived costs, risks, and benefits of the respective technology as key predictors of acceptance. Therefore, the present online study assessed this relationship for on-site systems in Bengaluru. The relation was analysed separately for mandated users of on-site systems (N = 103) and current non-users (i.e. potential prospective users, should the mandate be expanded; N = 232), as the perceptions might differ between the two groups, due to the personal experience with the technology among users. The results show that for mandated users and non-users, acceptance of on-site systems is explained by perceived benefits only, namely a positive image of users, environmental benefits, and, only for non-users, also financial benefits for the city. The findings suggest that interventions aimed at promoting on-site systems should include emphasis on the benefits of on-site systems. Whenever possible, interventions should be tailored to the target group's individual cost, risk, and benefit perception.


Subject(s)
Wastewater , Water Purification , Waste Disposal, Fluid/methods , Prospective Studies , India
4.
Water Res X ; 18: 100164, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-37250292

ABSTRACT

Widespread implementation of on-site water reuse systems is hindered by the limited ability to ensure the level of treatment and protection of human health during operation. In this study, we tested the ability of five commercially available online sensors (free chlorine (FC), oxidation-reduction potential (ORP), pH, turbidity, UV absorbance at 254 nm) to predict the microbial water quality in membrane bioreactors followed by chlorination using logistic regression-based and mechanism-based models. The microbial water quality was assessed in terms of removal of enteric bacteria from the wastewater, removal of enteric viruses, and regrowth of bacteria in the treated water. We found that FC and ORP alone could predict the microbial water quality well, with ORP-based models generally performing better. We further observed that prediction accuracy did not increase when data from multiple sensors were integrated. We propose a methodology to link online sensor measurements to risk-based water quality targets, providing operation setpoints protective of human health for specific combinations of wastewaters and reuse applications. For instance, we recommend a minimum ORP of 705 mV to ensure a virus log-removal of 5, and an ORP of 765 mV for a log-removal of 6. These setpoints were selected to ensure that the percentage of events where the water is predicted to meet the quality target but it does not remains below 5%. Such a systematic approach to set sensor setpoints could be used in the development of water reuse guidelines and regulations that aim to cover a range of reuse applications with differential risks to human health.

5.
Environ Sci Technol Lett ; 10(4): 379-384, 2023 Apr 11.
Article in English | MEDLINE | ID: mdl-37064823

ABSTRACT

Preventing failures of water treatment barriers can play an important role in meeting the increasing demand for microbiologically safe water. The development and integration of failure prevention strategies into quantitative microbial risk assessment (QMRA) offer opportunities to support the design and operation of treatment trains. This study presents existing failure models and extends them to guide the development of risk-based operational monitoring strategies. For barriers with rapid performance loss, results show that a failure of 15 s should be reliably detected to verify a log reduction value (LRV) of 6.0; thus, detecting and remediating these failures may be beyond current technology. For chemical disinfection with a residual, failure durations in order of minutes should be reliably detected to verify a LRV of 6.0. Short-term failures are buffered because the disinfectant residual concentration sustains a partial reduction performance. Therefore, increasing the contact time and hydraulic mixing reduces the impact of failures. These findings demonstrate the importance of defining precise frequencies to monitor barrier performances during operation. Overall, this study highlights the utility of process-specific models for developing failure prevention strategies for water safety management.

6.
Water Res X ; 13: 100124, 2021 Dec 01.
Article in English | MEDLINE | ID: mdl-34917915

ABSTRACT

We present the results of three field tests and three laboratory tests of a new physical-chemical urine treatment system, which can recover all nutrients, while pathogens are inactivated. The system consists of two steps. In the first reactor, biological processes including urea hydrolysis are prevented by mixing fresh urine with calcium hydroxide (Ca(OH)2). Due to the high pH value and the high availability of calcium, phosphate can be recovered by precipitation. The high pH value also fosters the inactivation of microorganisms, including pathogens. In the second reactor, water is evaporated at low energy consumption by blowing unheated ambient air over the stabilized urine. Stabilization in the first reactor was successful in all field and laboratory tests. The pH value remained between 12 and 13, except for short dips due to shortages of Ca(OH)2. Nearly all phosphorus (92-96%) precipitated and could be recovered as calcium phosphate in the first reactor, while nitrogen and potassium overflowed with the urine into the evaporation reactor. The efficiency of the second treatment step was very different for field and laboratory experiments and depended on the duration of the experiment. During a four-day laboratory test, nitrogen recovery was 98%. In contrast, nitrogen recovery was only around 20% in the long-term field experiments. The high nitrogen losses occurred, because biological urea hydrolysis was not inhibited anymore, when the pH value in the second reactor decreased due to the dissolution of high amounts of carbon dioxide from the ambient air. Potassium was not subject to any significant loss, and the measured recovery in the solid evaporation product was 98%. Evaporation rates ranged between 50 g m-2 h-1 (RH = 82±13%, T = 12±6°C) and 130 g m-2 h-1 (RH = 60±19%, T = 24±5°C) in the three field tests. Apart from some disturbances due to low supply of Ca(OH)2, the urine module functioned without any substantial failures and was simple to maintain. The minimum consumption of Ca(OH)2 at full capacity was 6 g·L-1 urine and the electricity demand was 150 Wh kg-1 water evaporated from urine, resulting in operational costs of 0.05 EUR pers-1 d-1.

7.
Sci Total Environ ; 796: 149024, 2021 Nov 20.
Article in English | MEDLINE | ID: mdl-34328886

ABSTRACT

Safe and accessible water services for hand hygiene are critical to human health and well-being. However, access to handwashing facilities is limited in cities in the Global South, where rapid urbanisation, service backlogs, lack of infrastructure and capacity, and water scarcity impact on the ability of local governments to provide them. Community participation and the co-production of knowledge in the development of innovative technologies, which are aligned with Water, Sanitation and Hygiene (WASH) principles, can lead to more sustainable and socially-acceptable hand hygiene systems. This paper presents the outcomes of the testing of the Autarky handwashing station, a technology that provides onsite treatment and recycling of handwashing water, in an informal settlement in Durban, South Africa. The transdisciplinary research approach adopted enabled the participation of multiple stakeholders with different knowledge systems in the framing, testing and evaluation of the system. The process of co-producing knowledge, as well as the outcomes of the testing, namely high levels of functionality and social acceptability of the technology, supported the WASH principles. The evaluation revealed that the Autarky handwashing station is a niche intervention that improved access to safe and appealing handwashing facilities in an informal settlement. Its novel design, socially desirable features, reliability and ability to save water increased its acceptance in the community. The testing of the system in a real-world context revealed the value of including communities in knowledge production processes for technology innovation. Further work is required to ensure that real-time monitoring of system function is feasible before such systems can be implemented at larger scale.


Subject(s)
Hand Disinfection , Hand Hygiene , Humans , Reproducibility of Results , Sanitation , South Africa , Water Supply
8.
Water Res X ; 11: 100094, 2021 May 01.
Article in English | MEDLINE | ID: mdl-33851106

ABSTRACT

Novel technologies allow to reuse or recycle water for on-site applications such as toilet flushing, showering, or hand washing at the household- or building-scale. Many of these technologies have now reached technology readiness levels that require for verification and validation testing in the field. Results from such field tests of decentralized water reuse systems have been published over the past few years, and observed performance is often compared to quality targets from water reuse frameworks (WRFs). An inspection of ten recent journal publications reveals that targets from WRFs are often misinterpreted, and the emphasis of these publications is too often on demonstrating successful aspects of the technologies rather than critically evaluating the quality of the produced water. We hypothesize that some of these misinterpretations are due to ambiguous definition of scopes of WRFs (e.g., "unrestricted urban reuse") and unclear applicability for novel recycling systems that treat the water for applications that go beyond the reuse scopes defined in current WRFs. Additional challenges are linked to the verification of WRF quality targets in small-scale and decentralized systems under economic and organizational constraints. Current WRFs are not suitable for all possible reuse cases, and there is need for a critical discussion of quality targets and associated monitoring methods. As the scope of water reuse has expanded greatly over the past years, WRFs need to address new applications and advances in technology, including in monitoring capacities.

9.
Water Res X ; 11: 100087, 2021 May 01.
Article in English | MEDLINE | ID: mdl-33665596

ABSTRACT

Greywater recycling systems designed for high-quality applications, such as hand washing, must deliver microbially safe and aesthetically acceptable water under the challenging operating conditions present where such systems are needed most urgently. As chlorination is the most popular strategy for reducing bacterial concentrations in greywater, understanding chlorination in the context of disruptive and challenging operation is essential to designing robust treatment. In this study, we have examined how disruptions through overall increased loading, interrupted aeration and increased ammonia loading have impacted the chlorine demand of the water produced by a greywater recycling system. We also presented concentrations of significant chemicals that contributed to this chlorine demand. The results indicate that a 1 d period with 8 times (8x) the normal design loading produced a peak chlorine demand of 0.74 mg Cl2/L, which is approximately double the baseline value. While this chlorine demand can be overcome by adding more chlorine, tests involving disruptions in aeration or feeding additional ammonia into the bioreactor produced much greater increases (>30x). The risks of increased chlorine demand on microbial safety can be overcome by limiting ammonia inputs to the system, providing backup systems to ensure sufficient aeration, or through additional anti-bacterial measures that do not depend on maintaining residual chlorine.

10.
Sci Total Environ ; 755(Pt 2): 143284, 2021 Feb 10.
Article in English | MEDLINE | ID: mdl-33168239

ABSTRACT

The provision of water and sanitation for all that is safe, dignified, reliable, affordable and sustainable is a major global challenge. While centralized sewer-based sanitation systems remain the dominant approach to providing sanitation, the benefits of non-sewered onsite sanitation systems are increasingly being recognised. This paper presents the outcomes of the testing of the Blue Diversion Autarky Toilet (BDAT), a sanitation system providing hygiene and dignity without relying on water and wastewater infrastructure, in a peri-urban household in Durban, South Africa. The BDAT was used by a single household as their only form of sanitation during three months of technical and social testing. An analysis based on technical data in combination with interpretive, qualitative research methods revealed that the BDAT functioned well and achieved high levels of social acceptance in the test household. The flushing, cleanliness and odour-free nature of the sanitation technology, its functionality, the household's previous sanitation experience, and their experience with and understanding of water scarcity, were the main factors underpinning their positive response to this innovation in sanitation. The testing process resulted in broader developmental benefits for the household, including improved basic services due to the upgrading of the electrical and existing sanitation system, social learning, and improved relationships between household members and the local state. A transdisciplinary research process, which emerged through the assessment, enabled the integration of different forms of knowledge from multiple actors to address the complexity of problems related to the development of socially just sanitation. The benefit of engaging with societal actors in sanitation innovation and assessing its outcomes using both the technical and social sciences is evident in this paper.


Subject(s)
Hygiene , Sanitation , Family Characteristics , South Africa , Water Supply
11.
Water Res X ; 7: 100051, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32462136

ABSTRACT

On-site wastewater reuse can improve global access to clean water, sanitation and hygiene. We developed a treatment system (aerated bioreactor, ultrafiltration membrane, granular activated carbon and electrolysis for chlorine disinfection) that recycles hand washing and toilet flush water. Three prototypes were field-tested in non-sewered areas, one in Switzerland (hand washing) and two in South Africa (hand washing, toilet flushing), over periods of 63, 74 and 94 days, respectively. We demonstrated that the system is able to recycle sufficient quantities of safe and appealing hand washing and toilet flush water for domestic or public use in real-life applications. Chemical contaminants were effectively removed from the used water in all prototypes. Removal efficiencies were 99.7% for the chemical oxygen demand (COD), 98.5% for total nitrogen (TN) and 99.9% for phosphate in a prototype treating hand washing water, and 99.8% for COD, 95.7% for TN and 89.6% for phosphate in a prototype treating toilet flush water. While this system allowed for true recycling for the same application, most on-site wastewater reuse systems downcycle the treated water, i.e., reuse it for an application requiring lower water quality. An analysis of 18 selected wastewater reuse specifications revealed that at best these guidelines are only partially applicable to innovative recycling systems as they are focused on the downcycling of water to the environment (e.g., use for irrigation). We believe that a paradigm shift is necessary and advocate for the implementation of risk-based (and thus end-use dependent) system performance targets to evaluate water treatment systems, which recycle and not only downcycle water.

12.
Sci Total Environ ; 721: 137489, 2020 Jun 15.
Article in English | MEDLINE | ID: mdl-32172099

ABSTRACT

Ozone, electrolysis and granular activated carbon (GAC) were examined as potential post-treatments to follow a household-scale biologically activated membrane bioreactor (BAMBi), treating a wash water containing trace urine and feces contamination. Each post-treatment was evaluated for abilities and reaction preferences to remove or transform dissolved organic carbon (DOC), chemical structures that contribute color, and assimilable organic carbon (AOC), which can support bacterial regrowth. Batch treatment with each technology demonstrated an ability to remove ≥95% DOC. Ozone demonstrated a reaction selectivity through increased reaction rates with larger compounds and color-contributing compounds. Electrolysis and GAC demonstrated generally less-selective reactivity. Adding post-treatments to full-scale systems reduced DOC (55-91%), AOC (34-62%), and color (75-98%), without significant reaction selectivity. These reductions in DOC and AOC were not linked to reduction of bacterial concentrations in treated water. Reductions in bacterial concentrations were observed with ozone and electrolysis, but this is credited to oxidation chemicals produced in these systems and not the removal or transformations of organic materials.


Subject(s)
Ozone , Water Pollutants, Chemical/analysis , Water Purification , Charcoal , Recycling , Water
13.
Water Res X ; 7: 100048, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32154508

ABSTRACT

Simultaneous nitrification-denitrification (SND) is, in theory, a key advantage of aerobic granular sludge systems over conventional activated sludge systems. But practical experience and literature suggests that SND and thus total nitrogen removal are limited during treatment of municipal wastewater using AGS systems. This study thus aims at quantifying the extent and understanding the mechanisms of SND during treatment of municipal wastewater with aerobic granular sludge (AGS) systems. Experiments (long-term and batch-tests) as well as mathematical modelling were performed. Our experimental results demonstrate that SND is significantly limited during treatment of low-strength municipal wastewater with AGS systems (14-39%), while almost full SND is observed when treating synthetic influent containing only diffusible substrate (90%). Our simulations demonstrate that the main mechanisms behind limited SND are (1) the dynamics of anoxic zone formation inside the granule, (2) the diffusibility and availability of electron-donors in those zones and (3) the aeration mode. The development of anoxic zones is driven by the utilisation of oxygen in the upper layers of the granule leading to transport limitations of oxygen inside the granule; this effect is closely linked to granule size and wastewater composition. Development of anoxic zones during the aerobic phase is limited for small granules at constant aeration at bulk dissolved oxygen (DO) concentration of 2 mgO2 L-1, and anoxic zones only develop during a brief period of the aerated phase for large granules. Modelling results further indicate that a large fraction of electron-donors are actually utilised in aerobic rather than anoxic redox zones - in the bulk or at the granule surface. Thus, full SND cannot be achieved with AGS treating low strength municipal wastewater if a constant DO is maintained during the aeration phase. Optimised aeration strategies are therefore required. 2-step and alternating aeration are tested successfully using mathematical modelling and increase TN removal to 40-79%, without compromising nitrification, and by shifting electron-donor utilisation towards anoxic redox conditions.

14.
Water Res ; 144: 752-762, 2018 11 01.
Article in English | MEDLINE | ID: mdl-30165322

ABSTRACT

On-site biological hand washing water treatment can improve global access to safe hand washing water, but requires a thorough understanding of the chemical composition of the water to be treated, and an effective treatment strategy. This study first presents a detailed characterization of the individual inputs to hand washing water. We demonstrate (i) that soap is likely the most significant input in hand washing water, representing ∼90% of mass loading, and (ii) that inputs to hand washing water have low concentrations of biologically-essential macro- and micro-nutrients (nitrogen, phosphorus, potassium, copper, zinc, molybdenum and cobalt) with respect to carbon, which may impair biological carbon removal. This study next formulates a recipe that recreates a representative composition of hand washing water and develops a procedure to identify and supplement nutrients in which this recipe is estimated to be deficient. Batch testing of the nutrient-supplemented hand washing water with an inoculum of planktonic bacteria demonstrated improved assimilable organic carbon removal (99% vs. 86% removal) and produced lower final dissolved organic carbon concentrations (1.7 mgC/L vs. 3.5 mgC/L) compared to realistic (nutrient-deficient) washing water. Supplementing nutrients did promote cell growth (50x higher final total cell count). Full-scale testing in a biologically activated membrane bioreactor (BAMBi) system treating 75 L/day of nutrient-supplemented hand washing water showed that long-term operation (100 days) can deliver effective carbon removal (95%) without detrimental fouling or other disruptions caused by cell growth. This work demonstrates that biological treatment in a BAMBi system, operated with appropriate nutrient-balancing offers an effective solution for decentralized treatment of light greywater.


Subject(s)
Nutrients , Water Purification , Hand Disinfection , Nitrogen , Phosphorus