Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
Add more filters











Publication year range
1.
J Bacteriol ; : e0014024, 2024 Sep 16.
Article in English | MEDLINE | ID: mdl-39283106

ABSTRACT

Powered by ion transport across the cell membrane, conserved ion-powered rotary motors (IRMs) drive bacterial motility by generating torque on the rotor of the bacterial flagellar motor. Homologous heteroheptameric IRMs have been structurally characterized in ion channels such as Tol/Ton/Exb/Gld, and most recently in phage defense systems such as Zor. Functional stator complexes synthesized from chimeras of PomB/MotB (PotB) have been used to study flagellar rotation at low ion-motive force achieved via reduced external sodium concentration. The function of such chimeras is highly sensitive to the location of the fusion site, and these hybrid proteins have thus far been arbitrarily designed. To date, no chimeras have been constructed using interchange of components from Tol/Ton/Exb/Gld and other ion-powered motors with more distant homology. Here, we synthesized chimeras of MotAB, PomAPotB, and ExbBD to assess their capacity for cross-compatibility. We generated motile strains powered by stator complexes with B-subunit chimeras. This motility was further optimized by directed evolution. Whole-genome sequencing of these strains revealed that motility-enhancing residue changes occurred in the A-subunit and at the peptidoglycan binding domain of the B-unit, which could improve motility. Overall, our work highlights the complexity of stator architecture and identifies the challenges associated with the rational design of chimeric IRMs. IMPORTANCE: Ion-powered rotary motors (IRMs) underpin the rotation of one of nature's oldest wheels, the flagellar motor. Recent structures show that this complex appears to be a fundamental molecular module with diverse biological utility where electrical energy is coupled to torque. Here, we attempted to rationally design chimeric IRMs to explore the cross-compatibility of these ancient motors. We succeeded in making one working chimera of a flagellar motor and a non-flagellar transport system protein. This had only a short hybrid stretch in the ion-conducting channel, and function was subsequently improved through additional substitutions at sites distant from this hybrid pore region. Our goal was to test the cross-compatibility of these homologous systems and highlight challenges arising when engineering new rotary motors.

2.
Protein Sci ; 32(12): e4811, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37870481

ABSTRACT

Many bacteria swim driven by an extracellular filament rotated by the bacterial flagellar motor. This motor is powered by the stator complex, MotA5 MotB2 , an heptameric complex which forms an ion channel which couples energy from the ion motive force to torque generation. Recent structural work revealed that stator complex consists of a ring of five MotA subunits which rotate around a central dimer of MotB subunits. Transmembrane (TM) domains TM3 and TM4 from MotA combine with the single TM domain from MotB to form two separate ion channels within this complex. Much is known about the ion binding site and ion specificity; however, to date, no modeling has been undertaken to explore the MotB-MotB dimer stability and the role of MotB conformational dynamics during rotation. Here, we modeled the central MotB dimer using coiled-coil engineering and modeling principles and calculated free energies to identify stable states in the operating cycle of the stator. We found three stable coiled-coil states with dimer interface angles of 28°, 56°, and 64°. We tested the effect of strategic mutagenesis on the comparative energy of the states and correlated motility with a specific hierarchy of stability between the three states. In general, our results indicate agreement with existing models describing a 36° rotation step of the MotA pentameric ring during the power stroke and provide an energetic basis for the coordinated rotation of the central MotB dimer based on coiled-coil modeling.


Subject(s)
Bacterial Proteins , Flagella , Bacterial Proteins/genetics , Bacterial Proteins/chemistry , Flagella/chemistry , Flagella/metabolism , Bacteria/metabolism , Protein Domains , Binding Sites
3.
Microlife ; 4: uqad011, 2023.
Article in English | MEDLINE | ID: mdl-37223728

ABSTRACT

The bacterial flagellar motor (BFM) is a rotary nanomachine powered by the translocation of ions across the inner membrane through the stator complex. The stator complex consists of two membrane proteins: MotA and MotB (in H+-powered motors), or PomA and PomB (in Na+-powered motors). In this study, we used ancestral sequence reconstruction (ASR) to probe which residues of MotA correlate with function and may have been conserved to preserve motor function. We reconstructed 10 ancestral sequences of MotA and found four of them were motile in combination with contemporary Escherichia coli MotB and in combination with our previously published functional ancestral MotBs. Sequence comparison between wild-type (WT) E. coli MotA and MotA-ASRs revealed 30 critical residues across multiple domains of MotA that were conserved among all motile stator units. These conserved residues included pore-facing, cytoplasm-facing, and MotA-MotA intermolecular facing sites. Overall, this work demonstrates the role of ASR in assessing conserved variable residues in a subunit of a molecular complex.

4.
Sci Adv ; 8(47): eabq2492, 2022 11 25.
Article in English | MEDLINE | ID: mdl-36417540

ABSTRACT

Determining which cellular processes facilitate adaptation requires a tractable experimental model where an environmental cue can generate variants that rescue function. The bacterial flagellar motor (BFM) is an excellent candidate-an ancient and highly conserved molecular complex for bacterial propulsion toward favorable environments. Motor rotation is often powered by H+ or Na+ ion transit through the torque-generating stator subunit of the motor complex, and ion selectivity has adapted over evolutionary time scales. Here, we used CRISPR engineering to replace the native Escherichia coli H+-powered stator with Na+-powered stator genes and report the spontaneous reversion of our edit in a low-sodium environment. We followed the evolution of the stators during their reversion to H+-powered motility and used both whole-genome and RNA sequencing to identify genes involved in the cell's adaptation. Our transplant of an unfit protein and the cells' rapid response to this edit demonstrate the adaptability of the stator subunit and highlight the hierarchical modularity of the flagellar motor.


Subject(s)
Escherichia coli , Flagella , Escherichia coli/genetics , Escherichia coli/metabolism , Flagella/metabolism , Molecular Motor Proteins/metabolism , Sodium/metabolism , Torque , Ions/metabolism
6.
Nucleic Acids Res ; 49(19): 10835-10850, 2021 11 08.
Article in English | MEDLINE | ID: mdl-34614184

ABSTRACT

Liposomes are widely used as synthetic analogues of cell membranes and for drug delivery. Lipid-binding DNA nanostructures can modify the shape, porosity and reactivity of liposomes, mediated by cholesterol modifications. DNA nanostructures can also be designed to switch conformations by DNA strand displacement. However, the optimal conditions to facilitate stable, high-yield DNA-lipid binding while allowing controlled switching by strand displacement are not known. Here, we characterized the effect of cholesterol arrangement, DNA structure, buffer and lipid composition on DNA-lipid binding and strand displacement. We observed that binding was inhibited below pH 4, and above 200 mM NaCl or 40 mM MgCl2, was independent of lipid type, and increased with membrane cholesterol content. For simple motifs, binding yield was slightly higher for double-stranded DNA than single-stranded DNA. For larger DNA origami tiles, four to eight cholesterol modifications were optimal, while edge positions and longer spacers increased yield of lipid binding. Strand displacement achieved controlled removal of DNA tiles from membranes, but was inhibited by overhang domains, which are used to prevent cholesterol aggregation. These findings provide design guidelines for integrating strand displacement switching with lipid-binding DNA nanostructures. This paves the way for achieving dynamic control of membrane morphology, enabling broader applications in nanomedicine and biophysics.


Subject(s)
DNA, Single-Stranded/metabolism , DNA/metabolism , Liposomes/metabolism , Phosphatidylcholines/metabolism , Phosphatidylethanolamines/metabolism , Cholesterol/chemistry , Cholesterol/metabolism , DNA/chemistry , DNA, Single-Stranded/chemistry , Hydrogen-Ion Concentration , Kinetics , Liposomes/chemistry , Magnesium Chloride/chemistry , Magnesium Chloride/metabolism , Nanostructures/chemistry , Nanostructures/ultrastructure , Nucleic Acid Conformation , Phosphatidylcholines/chemistry , Phosphatidylethanolamines/chemistry , Sodium Chloride/chemistry , Sodium Chloride/metabolism , Solutions , Thermodynamics
7.
J Gen Physiol ; 152(8)2020 08 03.
Article in English | MEDLINE | ID: mdl-32582958

ABSTRACT

The human mechanosensitive ion channel PIEZO1 is gated by membrane tension and regulates essential biological processes such as vascular development and erythrocyte volume homeostasis. Currently, little is known about PIEZO1 plasma membrane localization and organization. Using a PIEZO1-GFP fusion protein, we investigated whether cholesterol enrichment or depletion by methyl-ß-cyclodextrin (MBCD) and disruption of membrane cholesterol organization by dynasore affects PIEZO1-GFP's response to mechanical force. Electrophysiological recordings in the cell-attached configuration revealed that MBCD caused a rightward shift in the PIEZO1-GFP pressure-response curve, increased channel latency in response to mechanical stimuli, and markedly slowed channel inactivation. The same effects were seen in native PIEZO1 in N2A cells. STORM superresolution imaging revealed that, at the nanoscale, PIEZO1-GFP channels in the membrane associate as clusters sensitive to membrane manipulation. Both cluster distribution and diffusion rates were affected by treatment with MBCD (5 mM). Supplementation of polyunsaturated fatty acids appeared to sensitize the PIEZO1-GFP response to applied pressure. Together, our results indicate that PIEZO1 function is directly dependent on the membrane composition and lateral organization of membrane cholesterol domains, which coordinate the activity of clustered PIEZO1 channels.


Subject(s)
Cell Membrane/chemistry , Cholesterol/chemistry , Ion Channels , Mechanotransduction, Cellular , Humans , Ion Channels/physiology
8.
J Bacteriol ; 202(3)2020 01 15.
Article in English | MEDLINE | ID: mdl-31591272

ABSTRACT

The bacterial flagellar motor is driven by an ion flux that is converted to torque by motor-attendant complexes known as stators. The dynamics of stator assembly around the motor in response to external stimuli have been the subject of much recent research, but less is known about the evolutionary origins of stator complexes and how they select for specific ions. Here, we review the latest structural and biochemical data for the stator complexes and compare these with other ion transporters and microbial motors to examine possible evolutionary origins of the stator complex.


Subject(s)
Archaea/metabolism , Bacterial Proteins/metabolism , Flagella/metabolism , Flagella/physiology , Molecular Motor Proteins/metabolism , Archaea/genetics , Bacterial Proteins/genetics , Chemotaxis/genetics , Chemotaxis/physiology , Molecular Motor Proteins/genetics
9.
J Cell Sci ; 132(23)2019 12 10.
Article in English | MEDLINE | ID: mdl-31722978

ABSTRACT

TRP channels of the transient receptor potential ion channel superfamily are involved in a wide variety of mechanosensory processes, including touch sensation, pain, blood pressure regulation, bone loading and detection of cerebrospinal fluid flow. However, in many instances it is unclear whether TRP channels are the primary transducers of mechanical force in these processes. In this study, we tested stretch activation of eleven TRP channels from six mammalian subfamilies. We found that these TRP channels were insensitive to short membrane stretches in cellular systems. Furthermore, we purified TRPC6 and demonstrated its insensitivity to stretch in liposomes, an artificial bilayer system free from cellular components. Additionally, we demonstrated that, when expressed in C. elegans neurons, mouse TRPC6 restores the mechanoresponse of a touch insensitive mutant but requires diacylglycerol for activation. These results strongly suggest that the mammalian members of the TRP ion channel family are insensitive to tension induced by cell membrane stretching and, thus, are more likely to be activated by cytoplasmic tethers or downstream components and to act as amplifiers of cellular mechanosensory signaling cascades.


Subject(s)
TRPC6 Cation Channel/chemistry , Animals , CHO Cells , Caenorhabditis elegans/metabolism , Cricetulus , Electrophysiology , HEK293 Cells , HeLa Cells , Humans , Mechanotransduction, Cellular/physiology , Neurons/metabolism , Proteolipids/chemistry
10.
Biophys Rev ; 11(5): 795-805, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31494839

ABSTRACT

Mechanosensitive (MS) ion channels are integral membrane proteins which play a crucial role in fast signaling during mechanosensory transduction processes in living cells. They are ubiquitous and old in the evolutionary sense, given their presence in cells from all three kingdoms of life found on Earth, including bacterial, archaeal, and eukaryotic organisms. As molecular transducers of mechanical force, MS channels are activated by mechanical stimuli exerted on cellular membranes, upon which they rapidly and efficiently convert these stimuli into electrical, osmotic, and/or chemical intracellular signals. Most of what we know about the gating mechanisms of MS channels comes from the work carried out on bacterial channels. However, recent progress resulting from identification and structural information of eukaryotic K2P-type TREK and TRAAK as well as Piezo1 and Piezo2 MS channels has greatly contributed to our understanding of the common biophysical principles underlying the gating mechanism and evolutionary origins of these fascinating membrane proteins. Using Piezo1 channels as an example, we briefly describe in this review what we have learned about their biophysics, physiological functions, and potential roles in "mechanopathologies."

11.
Channels (Austin) ; 13(1): 102-109, 2019 12.
Article in English | MEDLINE | ID: mdl-30885080

ABSTRACT

Mechanosensitive ion channels are membrane gated pores which are activated by mechanical stimuli. The focus of this study is on Piezo1, a newly discovered, large, mammalian, mechanosensitive ion channel, which has been linked to diseases such as dehydrated hereditary stomatocytosis (Xerocytosis) and lymphatic dysplasia. Here we utilize an established in-vitro artificial bilayer system to interrogate single Piezo1 channel activity. The droplet-hydrogel bilayer (DHB) system uniquely allows the simultaneous recording of electrical activity and fluorescence imaging of labelled protein. We successfully reconstituted fluorescently labelled Piezo1 ion channels in DHBs and verified activity using electrophysiology in the same system. We demonstrate successful insertion and activation of hPiezo1-GFP in bilayers of varying composition. Furthermore, we compare the Piezo1 bilayer reconstitution with measurements of insertion and activation of KcsA channels to reproduce the channel conductances reported in the literature. Together, our results showcase the use of DHBs for future experiments allowing simultaneous measurements of ion channel gating while visualising the channel proteins using fluorescence.


Subject(s)
Hydrogels/chemistry , Ion Channels/chemistry , Lipid Bilayers/chemistry , Humans , Hydrogels/metabolism , Ion Channels/metabolism , Lipid Bilayers/metabolism , Microscopy, Fluorescence , Optical Imaging , Particle Size , Surface Properties
12.
Biophys Rev ; 10(5): 1377-1384, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30182202

ABSTRACT

Mechanical stimuli acting on the cellular membrane are linked to intracellular signaling events and downstream effectors via different mechanoreceptors. Mechanosensitive (MS) ion channels are the fastest known primary mechano-electrical transducers, which convert mechanical stimuli into meaningful intracellular signals on a submillisecond time scale. Much of our understanding of the biophysical principles that underlie and regulate conversion of mechanical force into conformational changes in MS channels comes from studies based on MS channel reconstitution into lipid bilayers. The bilayer reconstitution methods have enabled researchers to investigate the structure-function relationship in MS channels and probe their specific interactions with their membrane lipid environment. This brief review focuses on close interactions between MS channels and the lipid bilayer and emphasizes the central role that the transbilayer pressure profile plays in mechanosensitivity and gating of these fascinating membrane proteins.

13.
J Mech Behav Biomed Mater ; 79: 158-167, 2018 03.
Article in English | MEDLINE | ID: mdl-29304430

ABSTRACT

The level of fatty acid saturation in phospholipids is a crucial determinant of the biophysical properties of the lipid bilayer. Integral membrane proteins are sensitive to changes of their bilayer environment such that their activities and localization can be profoundly affected. When incorporated into phospholipids of mammalian cells, poly-unsaturated fatty acids (PUFAs) determine the mechanical properties of the bilayer thereby affecting several membrane-associated functions such as endo- and exo-cytosis and ion channel/membrane receptor signalling cascades. In order to understand how membrane tension is propagated through poly-unsaturated bilayers, we characterized the effect of lipid saturation on liposome reconstituted MscS and MscL, the two bacterial mechanosensitive ion channels that have for many years served as models of ion- channel-mediated mechanotransduction. The combination of NMR and patch clamp experiments in this study demonstrate that bilayer thinning is the main responsible factor for the modulation of the MscL threshold of activation while a change in transbilayer pressure profile is indicated as the main factor behind the observed modulation of the MscS kinetics. Together, our data offer a novel insight into how the structural shape differences between the two types of mechanosensitive channels determine their differential modulation by poly-unsaturated phospholipids and thus lay the foundation for future functional studies of eukaryotic ion channels involved in the physiology of mechanosensory transduction processes in mammalian cells. SUMMARY: Mechanosensitive channels MscL and MscS are differentially modulated by poly-unsaturated fatty acids in lipid bilayers. MscL becomes sensitized because of increased hydrophobic mismatch while MscS open state is stabilized due to changes in the bilayer lateral pressure profile determined by NMR.


Subject(s)
Escherichia coli Proteins/metabolism , Fatty Acids, Unsaturated/metabolism , Lipid Bilayers/metabolism , Mechanotransduction, Cellular/physiology , Escherichia coli , Liposomes/metabolism
14.
Sci Rep ; 7(1): 17229, 2017 12 08.
Article in English | MEDLINE | ID: mdl-29222414

ABSTRACT

The large conductance mechanosensitive channel (MscL), acts as an osmoprotective emergency valve in bacteria by opening a large, water-filled pore in response to changes in membrane tension. In its closed configuration, the last 36 residues at the C-terminus form a bundle of five α-helices co-linear with the five-fold axis of symmetry. Here, we examined the structural dynamics of the C-terminus of EcMscL using site-directed spin labelling electron paramagnetic resonance (SDSL EPR) spectroscopy. These experiments were complemented with computational modelling including molecular dynamics (MD) simulations and finite element (FE) modelling. Our results show that under physiological conditions, the C-terminus is indeed an α-helical bundle, located near the five-fold symmetry axis of the molecule. Both experiments and computational modelling demonstrate that only the top part of the C-terminal domain (from the residue A110 to E118) dissociates during the channel gating, while the rest of the C-terminus stays assembled. This result is consistent with the view that the C-terminus functions as a molecular sieve and stabilizer of the oligomeric MscL structure as previously suggested.


Subject(s)
Escherichia coli Proteins/chemistry , Escherichia coli Proteins/metabolism , Ion Channels/chemistry , Ion Channels/metabolism , Amino Acid Sequence , Escherichia coli Proteins/genetics , Finite Element Analysis , Ion Channels/genetics , Molecular Dynamics Simulation , Mutagenesis , Protein Domains , Protein Multimerization , Protein Structure, Quaternary
15.
Sci Rep ; 7: 45180, 2017 03 27.
Article in English | MEDLINE | ID: mdl-28345591

ABSTRACT

The droplet on hydrogel bilayer (DHB) is a novel platform for investigating the function of ion channels. Advantages of this setup include tight control of all bilayer components, which is compelling for the investigation of mechanosensitive (MS) ion channels, since they are highly sensitive to their lipid environment. However, the activation of MS ion channels in planar supported lipid bilayers, such as the DHB, has not yet been established. Here we present the activation of the large conductance MS channel of E. coli, (MscL), in DHBs. By selectively stretching the droplet monolayer with nanolitre injections of buffer, we induced quantifiable DHB tension, which could be related to channel activity. The MscL activity response revealed that the droplet monolayer tension equilibrated over time, likely by insertion of lipid from solution. Our study thus establishes a method to controllably activate MS channels in DHBs and thereby advances studies of MS channels in this novel platform.


Subject(s)
Escherichia coli Proteins/metabolism , Escherichia coli/metabolism , Ion Channels/metabolism , Mechanotransduction, Cellular , Escherichia coli/genetics , Escherichia coli Proteins/genetics , Hydrogels , Ion Channels/genetics , Lipid Bilayers/metabolism , Lipid Droplets/metabolism , Mutation
16.
Eur Biophys J ; 44(7): 589-98, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26233759

ABSTRACT

The mechanosensitive channel of large conductance MscL is a well-characterized mechanically gated non-selective ion channel, which often serves as a prototype mechanosensitive channel for mechanotransduction studies. However, there are some discrepancies between MscL constructs used in these studies, most notably unintended heterogeneous expression from some MscL expression constructs. In this study we investigate the possible cause of this expression pattern, and compare the original non-homogenously expressing constructs with our new homogeneously expressing one to confirm that there is little functional difference between them. In addition, a new MscL construct has been developed with an improved molar extinction coefficient at 280 nm, enabling more accurate protein quantification.


Subject(s)
Escherichia coli Proteins/metabolism , Ion Channels/metabolism , Amino Acid Sequence , Codon , Escherichia coli/genetics , Escherichia coli/metabolism , Escherichia coli Proteins/chemistry , Escherichia coli Proteins/genetics , Ion Channels/chemistry , Ion Channels/genetics , Liposomes/metabolism , Molecular Sequence Data , Protein Structure, Tertiary
17.
Eur Biophys J ; 44(7): 567-76, 2015 Oct.
Article in English | MEDLINE | ID: mdl-25842033

ABSTRACT

The bacterial mechanosensitive channels MscS and MscL are gated by an increase in membrane tension when the bacterium experiences hypoosmotic shock. It has been well established that membrane lipids modulate the mechanosensitivity and gating behavior of these channels. The focus of this study is a negatively charged phospholipid, cardiolipin, which has been shown to localize at curved regions of the bacterial cell, including the poles and the septum, and to have a strong preference for binding to membrane proteins. Here we characterize the effect of cardiolipin on MscS, the mechanosensitive channel of small conductance, using patch-clamp electrophysiology. We compare the gating kinetics and mechanosensitivity of the channel in both azolectin and mixtures of pure lipids DOPE/DOPC liposomes with and without cardiolipin. In azolectin liposomes, the addition of 10 % cardiolipin abolishes hysteresis of MscS, but MscL remains largely unaffected, indicating that cardiolipin may stabilize the closed state of MscS. On the other hand, mixtures of DOPE/DOPC abolish the hysteresis gating of MscS even in the absence of cardiolipin, and the addition of cardiolipin increases the opening and closing thresholds of both MscS and MscL. In addition, we show that MscS gates more frequently when cardiolipin is present in both the azolectin and pure lipid systems; this dose-dependent effect ultimately destabilizes the open state of MscS and we consider the functional implications of this cardiolipin effect in the bacterial osmotic response. Our results show that cardiolipin modulates the mechanosensitivity and gating characteristics of MscS, indicating its important role in the physiology of bacterial cells.


Subject(s)
Cardiolipins/pharmacology , Escherichia coli Proteins/metabolism , Ion Channel Gating/drug effects , Ion Channels/metabolism , Action Potentials/drug effects , Amino Acid Sequence , Escherichia coli Proteins/chemistry , Ion Channels/chemistry , Liposomes/chemistry , Liposomes/metabolism , Molecular Sequence Data , Patch-Clamp Techniques
18.
Sci Rep ; 4: 5609, 2014 Jul 17.
Article in English | MEDLINE | ID: mdl-25030051

ABSTRACT

Multi-drug resistance is becoming an increasing problem in the treatment of bacterial infections and diseases. The mechanosensitive channel of large conductance (MscL) is highly conserved among prokaryotes. Evidence suggests that a pharmacological agent that can affect the gating of, or block the current through, MscL has significant potential as a new class of antimicrobial compound capable of targeting a range of pathogenic bacteria with minimal side-effects to infected patients. Using molecular dynamics we examine the binding of fullerenes and nanotubes to MscL and demonstrate that both are stable within the MscL pore. We predict that fullerenes will attenuate the flow of ions through MscL by reducing the pore volume available to water and ions, but nanotubes will prevent pore closure resulting in a permanently open pore. Moreover, we confirm experimentally that it is possible to attenuate the flow of ions through MscL using a C60-γ cyclodextrin complex.


Subject(s)
Escherichia coli Proteins/chemistry , Fullerenes/chemistry , Ion Channels/chemistry , Molecular Dynamics Simulation , Nanotubes, Carbon/chemistry , Binding Sites , Boron Compounds/chemistry , Protein Binding
SELECTION OF CITATIONS
SEARCH DETAIL