Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 11 de 11
1.
BMC Ophthalmol ; 24(1): 9, 2024 Jan 04.
Article En | MEDLINE | ID: mdl-38178013

In this review, we presented the principles of radial keratotomy (RK), its evolution, enhancement, and complications, and strategies to manage the consequences of RK in the present day. It is essential to understand the RK procedure f, the theoretical background that supported this surgery, the current effect on the cornea, and how to approach patients needing vision improvement. These patients are developing cataracts that need to be handled well, from the IOL calculation to the surgical procedure. Guided keratorefractive surgery is the most accurate procedure to improve these patient's vision and life. Nevertheless, some patients may need other approaches, such as sutures, penetrating keratoplasty, corneal rings, and pinhole implants, depending on the degree of irregularity of the cornea, ablation depth for guided surgery or if the sutures are open.


Keratotomy, Radial , Refractive Surgical Procedures , Humans , Keratotomy, Radial/adverse effects , Keratotomy, Radial/methods , Cornea/surgery , Keratoplasty, Penetrating
2.
Cornea ; 43(2): 190-194, 2024 Feb 01.
Article En | MEDLINE | ID: mdl-37039699

PURPOSE: The aim of this study was to evaluate the quality of life (QOL) after intrastromal ring implantation in patients with keratoconus. METHODS: This was a prospective, randomized, interventional study. We analyzed 60 eyes of 30 patients aged 16 to 35 years who were treated at the Department of Ophthalmology and Visual Sciences, Federal University of São Paulo, Brazil. The Visual Function Questionnaire (VFQ-25) and Short-Form 36 Questionnaire (SF-36) were used before intracorneal ring segment (ICRS) implantation and at 3, 6, and 12 months after surgical intervention. RESULTS: The mean corrected visual acuity improved from a mean of 0.32 ± 0.2 logMAR (20/40) preoperatively to 0.14 ± 0.11 logMAR (20/25) 1 year postoperatively ( P = 0.001). The mean spherical equivalent varied from -7.24 ± 3.47 preoperatively to -4.13 ± 2.41 postoperatively ( P = 0.001). The overall composite score for the VFQ-25 improved from 55.1 preoperatively to 80.4 1 postoperatively ( P = 0.001). SF-36 showed statistically significant improvement in all scores. When analyzing the correlation between visual acuity and VFQ composite score, a significant correlation was found between both variables (Pearson correlation coefficient of -0.40, P = 0.001). CONCLUSIONS: Patients with keratoconus had increased psychological symptoms and lower QOL and improved psychosocial criteria associated with corneal remodeling and decreased visual dependence on others after surgery. Extrapolation of these data to the whole keratoconus population suggests that ICRS implantation could improve QOL in these patients.


Keratoconus , Humans , Corneal Stroma/surgery , Corneal Topography , Prospective Studies , Prostheses and Implants , Prosthesis Implantation , Quality of Life , Refraction, Ocular , Adolescent , Young Adult , Adult
3.
Arq. bras. oftalmol ; 87(4): e2022, 2024. tab, graf
Article En | LILACS-Express | LILACS | ID: biblio-1520232

ABSTRACT Purpose: To compare the differences between the apparent and actual chord μ. Methods: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. Results: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord μ. The mean actual and apparent chord μ were 226.21 ± 128.53 and 278.66 ± 123.90 μm, respectively, with a mean difference of 52.45 μm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. Conclusions: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.


RESUMO Objetivo: Comparar as diferenças entre a chord aparente μ e o chord real μ. Métodos: Estudo prospectivo, comparativo, não randomizado e não intervencionista. Os exames de imagem (Pentacam e HD Analyzer) foram realizados na mesma sala e nas mesmas condições escotópicas. Os critérios de inclusão foram idade de 21 a 71 anos; compreensão do termo de consentimento; miopia até 4D e astigmatismo topográfico anterior até 1D. Os critérios de exclusão foram usuários de lentes de contato; pacientes com doenças oculares prévias ou cirurgias; opacidades da córnea; a presença de alterações tomográficas da córnea ou suspeita de ceratocone. Resultados: Em nosso estudo foram analisados 116 olhos de 58 pacientes. A média de idade foi de 30,69 anos (± 7,85). Análises de correlação foram desenvolvidas e o coeficiente de correlação de Pearson (0,647) indica uma relação linear positiva moderada entre as variáveis. A média do chord μ real foi 226,21 ± 128,53 μm e a média do chord μ média foi 278,66 ± 123,90 μm, com diferença média de 52,45 μm (p=0,01). A análise do diâmetro pupilar médio apresentou: 5,76mm no HD Analyzer e 3,31mm no Pentacam. Conclusões: Entendemos a existência de uma diferença significativa entre os métodos e assim a medida de ambos os dispositivos com base em princípios diferentes devemos respeitar suas peculiaridades. Como encontramos correlação entre as duas medidas, acreditamos que ambas podem ser utilizadas na prática diária.

4.
Indian J Ophthalmol ; 71(9): 3210-3218, 2023 09.
Article En | MEDLINE | ID: mdl-37602610

Purpose: Compare the safety and efficacy of wavefront-guided photorefractive keratotomy (PRK) 6 months after cross-linking (CXL) to wavefront-guided PRK alone for refractive correction in patients with bilateral asymmetric corneal topography. Methods: Prospective randomized clinical trial with 16 patients (32 eyes). CXL with subsequent PRK after 6 months in one eye, and PRK alone was performed in contralateral eyes. The follow-up was 10 years. We analyzed visual outcomes, Scheimpflug topography, and corneal haze evaluation. Results: Eyes in the PRK group showed better results than in the CXL + PRK group. Mean postoperative CDVA was 0.044 logmar (SD, 0.073) in the PRK group and 0.1 logmar (SD, 0.21) in the CXL + PRK group, the mean sphere was + 0.21 (SD, 0.6) D in the PRK group and 0.87 (SD, 2.3) D in the CXL + PRK group, and mean SE was -0.35 (SD, 0.65) D in the PRK group and 0.62 (SD, 2.32) D in the CXL + PRK group. In one patient, a steepening of 2.5 D and a thinning of 17 µm occurred in PRK alone group. Two patients in the CXL + PRK group presented corneal haze. The overall complication rate was 18,75% (haze and ectasia). Conclusion: Non-simultaneous CXL and PRK procedures yielded good refractive results, but worse than those obtained with PRK alone. Although one patient in the PRK group developed corneal ectasia, the CXL + PRK group had a higher loss of vision lines, indicating less safety.


Corneal Cross-Linking , Corneal Opacity , Humans , Corneal Topography , Dilatation, Pathologic , Follow-Up Studies , Prospective Studies
5.
Curr Eye Res ; 48(8): 731-735, 2023 08.
Article En | MEDLINE | ID: mdl-37092541

PURPOSE: This study evaluated the luminous behavior applied to materials used in intraocular surgeries. METHODS: Discs of the different products were delivered in 19.00 mm × 3.00 mm. Each sample was fixed on support keeping it perpendicular to the spectrophotometer beam. Later, their analyses were carried out in the air/PMMA ratio. The graphs of individual profiles of the measurements along the length were constructed according to each of the filters from the spectrophotometric analysis. In addition, descriptive statistics of transmittance and absorbance for each wavelength presented were correlated for each filter. RESULTS: It is possible to observe that the minimum absorption measure was found in the Red Filter, especially in the blue and green light spectrum. CONCLUSION: Using filters in PMMA materials appears to improve visual quality in corneal implants, especially the red filter, due to greater absorbance of light leading to fewer light scattering phenomena through corneal rings. However, further studies comparing the effects of different filters on Intracorneal rings should be carried out to elucidate this field of study.


Polymethyl Methacrylate , Prostheses and Implants , Prosthesis Implantation , Spectrophotometry
6.
Arq Bras Oftalmol ; 2023 Mar 24.
Article En | MEDLINE | ID: mdl-36995814

PURPOSE: To compare the differences between the apparent and actual chord µ. METHODS: In this prospective, comparative, non-randomized, and non-interventional study, imaging examinations using Pentacam and the HD Analyzer were performed in the same room under the same scotopic conditions. The inclusion criteria were patients aged 21-71 years, able to provide informed consent, myopia up to 4D, and anterior topographic astigmatism up to 1D. Patients using contact lenses, those with previous eye diseases or surgeries, corneal opacities, corneal tomographic changes, or suspected keratoconus were excluded. RESULTS: Altogether, 116 eyes of 58 patients were analyzed. The patients' mean age was 30.69 (±7.85) years. In the correlation analyses, Pearson's correlation coefficient of 0.647 indicates a moderate positive linear relationship between apparent and actual chord µ. The mean actual and apparent chord µ were 226.21 ± 128.53 and 278.66 ± 123.90 µm, respectively, with a mean difference of 52.45 µm (p=0.01). The analysis of mean pupillary diameter resulted in 5.76 mm using the HD Analyzer and 3.31 mm using the Pentacam. CONCLUSIONS: We found a correlation between the two measurement devices, and even though we found considerable differences, both can be used in daily practice. Given their differences, we should respect their peculiarities as well.

7.
Eur J Ophthalmol ; 32(5): 3103-3109, 2022 Sep.
Article En | MEDLINE | ID: mdl-35348412

PURPOSE: Report a new technique for improvement of pterygium surgery: donor graft harvesting with air. CASE REPORTS: We describe a technique that was used with 138 patients who underwent surgery that included a conjunctival autograft and fibrin glue with air injection to dissect the Tenon capsule from the conjunctiva. RESULTS: No complications occurred with this technique and all patients achieved good results. DISCUSSION: The surgical time with this new technique was similar to that reported in the literature. In addition, the graft thickness was close to that reported with femtosecond laser dissection and it was thinner than that reported with aesthetic/saline dissection (unable to determine statistical significance). CONCLUSIONS AND IMPORTANCE: With the injection of an air bubble, we could easily dissect the conjunctiva from the Tenon capsule and quickly acquire thin grafts without any additional costs or complications.


Pterygium , Tissue Adhesives , Conjunctiva/transplantation , Fibrin Tissue Adhesive/therapeutic use , Follow-Up Studies , Humans , Postoperative Complications , Pterygium/surgery , Transplantation, Autologous
8.
Eur J Ophthalmol ; 31(6): 3505-3510, 2021 Nov.
Article En | MEDLINE | ID: mdl-34058904

OBJECTIVE: Evaluation of central corneal densitometry changes following Ferrara corneal ring segment implantation in patients with keratoconus, especially the correlation between corneal densitometry and keratometry. METHODS: Retrospective, non-comparative, interventional study based on the review of medical records of patients diagnosed with keratoconus who underwent Ferrara corneal ring segment implantation. Pre and post-operative corneal densitometry measurements obtained with Pentacam HR (Oculus, Wetzlar, Germany) were analyzed. The follow-up time was 3 months, and data comparison was made, using specific statistical analysis, with the data of 3 months postoperatively. RESULTS: The study sample consisted of 43 eyes of 36 patients. The mean corrected visual acuity improved from 0.82 LogMAR preoperatively (SD ± 0.33) to 0.19 LogMAR (SD ± 0.13) postoperatively. The mean spherical equivalent varied from -4.63 (SD ± 3.94) preoperatively to -2.16 (SD ± 2.63) postoperatively. Asphericity varied from -0.69 (SD ± 0.32) preoperatively to -0.27 (SD ± 0.31) postoperatively. The mean maximum K was 54.01D (SD ± 3.38) preoperatively and 51.50D (SD ± 2.90) postoperatively. The mean anterior densitometric value was 18.26 (SD ± 2.03) preoperatively and 17.66 (SD ± 1.84) postoperatively. CONCLUSION: Corneal densitometry is an interesting technology that should be studied in keratoconus patients. Our results suggest that the corneal densitometry in the cornea's anterior layer reduces after ICRS implantation and correlates with corneal keratometry. Further studies should be performed to increase the knowledge in this field.


Keratoconus , Cornea/diagnostic imaging , Corneal Stroma/diagnostic imaging , Corneal Stroma/surgery , Corneal Topography , Densitometry , Humans , Keratoconus/surgery , Prostheses and Implants , Prosthesis Implantation , Refraction, Ocular , Retrospective Studies , Visual Acuity
9.
Eur J Ophthalmol ; 31(6): 3483-3489, 2021 Nov.
Article En | MEDLINE | ID: mdl-33719637

OBJECTIVE: To investigate the role of ICRS in halting keratoconus progression in a large sample of patients. METHODS: A retrospective, non-comparative, interventional study based on the review of medical records of patients diagnosed with keratoconus who underwent Ferrara corneal ring segment implantation. A retrospective chart analysis study of 123 operated eyes with follow-up ranging from 3 to 16 years (mean 5.3 ± 3.6 years) was performed. This study was carried out at Ocular Surgery Unit, São Paulo, Brazil. All topographic data were obtained from Pentacam (Oculus, Arlington, USA). The same surgeon performed all surgeries, and the Ferrara ICRS nomogram was used for ICRS selection in all cases. RESULTS: Corrected distance visual acuity, keratometry, and topographic astigmatism improved in most cases, with statistical significance. In 42 eyes (53.8%), there was an increase in K1 or K2, and in 36 (46.2%), there was a reduction or maintenance in K1. Considering a difference higher than 1 D, between 3-month post-surgery and final visit (group 3), 32 eyes (41%) showed an increase, and 46 eyes (59%) ended equal or below this value. CONCLUSION: The implantation of ICRS showed improvement in visual and keratometric indexes. The majority of patients did not increase more than one diopter in keratometric values after ICRS implantation. ICRS may be effective for slowing disease progression, especially in older patients.


Keratoconus , Aged , Brazil , Corneal Stroma/surgery , Corneal Topography , Humans , Keratoconus/surgery , Prostheses and Implants , Prosthesis Implantation , Refraction, Ocular , Retrospective Studies
10.
Arq Bras Oftalmol ; 76(4): 218-20, 2013.
Article En | MEDLINE | ID: mdl-24061831

PURPOSE: The optical correction of presbyopia must be handled individually. Our aim was to compare the methods used in addition to the refractive near vision, with the final addition used in presbyopic patients. METHODS: Eighty healthy subjects with a mean age of 49.7 years (range 40 to 60 years) were studied. Tentative near additions were determined using four different techniques: one-half amplitude accommodation with minus lenses (AAL); one-third accommodative demand with positive lens (ADL); balanced range of accommodation with minus and positive lenses (BRA) and crossed cylinder test with initial myopisation (CCT). The power of the addition was then refined to arrive at the final addition. RESULTS: The mean tentative near additions were lower than the final addition for ADL and BRA addition methods. The mean differences between tentative and final additions were low for all the tests examined (less than 0.25 D). The intervals between the 95% limits of agreement differed substantially and were always higher than ±0.50 D. CONCLUSION: All the methods used displayed similar behavior and provided a tentative addition close to the final addition. The coefficient of agreements (COA) detected suggests that every tentative addition should be adjusted according to the particular needs of the patient.


Accommodation, Ocular/physiology , Eyeglasses , Presbyopia/therapy , Adult , Cross-Sectional Studies , Depth Perception/physiology , Female , Humans , Male , Middle Aged , Reference Values , Reproducibility of Results , Visual Acuity
11.
Arq. bras. oftalmol ; 76(4): 218-220, jul.-ago. 2013. graf, tab
Article En | LILACS | ID: lil-686556

PURPOSE: The optical correction of presbyopia must be handled individually. Our aim was to compare the methods used in addition to the refractive near vision, with the final addition used in presbyopic patients. METHODS: Eighty healthy subjects with a mean age of 49.7 years (range 40 to 60 years) were studied. Tentative near additions were determined using four different techniques: one-half amplitude accommodation with minus lenses (AAL); one-third accommodative demand with positive lens (ADL); balanced range of accommodation with minus and positive lenses (BRA) and crossed cylinder test with initial myopisation (CCT). The power of the addition was then refined to arrive at the final addition. RESULTS: The mean tentative near additions were lower than the final addition for ADL and BRA addition methods. The mean differences between tentative and final additions were low for all the tests examined (less than 0.25 D). The intervals between the 95% limits of agreement differed substantially and were always higher than ±0.50 D. CONCLUSION: All the methods used displayed similar behavior and provided a tentative addition close to the final addition. The coefficient of agreements (COA) detected suggests that every tentative addition should be adjusted according to the particular needs of the patient.


OBJETIVO: A correção óptica da presbiopia deve ser manejada individualmente. Nosso intuito é de comparar os métodos usados para calcular a adição na elaboração do grau para perto em pacientes présbitas. MÉTODOS: Oitenta pacientes com média de idade de 49,7 anos (intervalo de 40 a 60 anos) foram estudados. Adições provisórias foram determinadas usando quatro diferentes técnicas: metade da amplitude de acomodação com lentes negativas (AAL); um terço da demanda acomodativa com lentes positivas (ADL); média aritmética da acomodação usando lentes positivas e negativas (BRA); teste com o cilindro cruzado com miopização (CCT). O grau final foi refinado até chegar a graduação final da adição. RESULTADOS: A média das adições nos testes foram menores que as adições finais nos métodos ADL e BRA. As diferenças médias entre os testes e o grau final foram baixas em todos os métodos (menores que +0,25 D). Os intervalos entre os 95% dos limites da concordância diferenciaram substancialmente e foram todos maiores que ±0.50 D. CONCLUSÃO: Todos os métodos usados demonstraram comportamentos similares e forneceram resultados bem próximos da adição final. O coeficiente de concordância (COA) detectado, sugere que todos os métodos utilizados devem ser ajustados de acordo com as necessidades do paciente.


Adult , Female , Humans , Male , Middle Aged , Accommodation, Ocular/physiology , Eyeglasses , Presbyopia/therapy , Cross-Sectional Studies , Depth Perception/physiology , Reference Values , Reproducibility of Results , Visual Acuity
...