1.
JTCVS Open ; 15: 291-299, 2023 Sep.
Article En | MEDLINE | ID: mdl-37808019

Objective: Implantation of an appropriately sized donor heart is critical for optimal outcomes after heart transplantation. Although predicted heart mass has recently gained consideration, there remains a need for improved granularity in size matching, particularly among small donor hearts. We sought to determine if indexed donor cardiac output is a sensitive metric to assess the adequacy of a donor heart for a given recipient. Methods: A retrospective analysis was performed (2003-2021) in isolated orthotopic heart transplant recipients from the United Network for Organ Sharing database. Donor cardiac output was divided by recipient body surface area to compute cardiac index (donor cardiac index). Predicted heart mass ratio was computed as donor/recipient predicted heart mass. The primary outcome was mortality 1 year after transplant. Results: Among transplant recipients, median donor cardiac output was 7.3 (5.8-9.0) liters per minute and donor cardiac index was 3.7 (3.0-4.6) liters per minute/m2. Predicted heart mass ratio was 1.01 (0.91-1.13). After multivariable adjustment, higher donor cardiac index was associated with lower 1-year mortality risk (odds ratio, 0.92, P = .042). Recipients with predicted heart mass ratio less than 0.80 (n = 255) had a lower median donor cardiac index than those with a predicted heart mass ratio of 0.80 or greater (3.2 vs 3.7, P < .001). As predicted, heart mass ratio became smaller and the association between donor cardiac index and 1-year mortality became progressively stronger. Conclusions: Higher donor cardiac index was associated with a lower probability of 1-year mortality among patients undergoing heart transplantation and served to further quantify mortality risk among those with a small predicted heart mass ratio. Donor cardiac index appears to be an effective tool for size matching and may serve as an adjunctive strategy among small donor hearts with a low predicted heart mass ratio.

2.
Anesthesiology ; 139(6): 815-826, 2023 12 01.
Article En | MEDLINE | ID: mdl-37566686

BACKGROUND: Bedside electrical impedance tomography could be useful to visualize evolving pulmonary perfusion distributions when acute respiratory distress syndrome worsens or in response to ventilatory and positional therapies. In experimental acute respiratory distress syndrome, this study evaluated the agreement of electrical impedance tomography and dynamic contrast-enhanced computed tomography perfusion distributions at two injury time points and in response to increased positive end-expiratory pressure (PEEP) and prone position. METHODS: Eleven mechanically ventilated (VT 8 ml · kg-1) Yorkshire pigs (five male, six female) received bronchial hydrochloric acid (3.5 ml · kg-1) to invoke lung injury. Electrical impedance tomography and computed tomography perfusion images were obtained at 2 h (early injury) and 24 h (late injury) after injury in supine position with PEEP 5 and 10 cm H2O. In eight animals, electrical impedance tomography and computed tomography perfusion imaging were also conducted in the prone position. Electrical impedance tomography perfusion (QEIT) and computed tomography perfusion (QCT) values (as percentages of image total) were compared in eight vertical regions across injury stages, levels of PEEP, and body positions using mixed-effects linear regression. The primary outcome was agreement between QEIT and QCT, defined using limits of agreement and Pearson correlation coefficient. RESULTS: Pao2/Fio2 decreased over the course of the experiment (healthy to early injury, -253 [95% CI, -317 to -189]; early to late injury, -88 [95% CI, -151 to -24]). The limits of agreement between QEIT and QCT were -4.66% and 4.73% for the middle 50% quantile of average regional perfusion, and the correlation coefficient was 0.88 (95% CI, 0.86 to 0.90]; P < 0.001). Electrical impedance tomography and computed tomography showed similar perfusion redistributions over injury stages and in response to increased PEEP. QEIT redistributions after positional therapy underestimated QCT in ventral regions and overestimated QCT in dorsal regions. CONCLUSIONS: Electrical impedance tomography closely approximated computed tomography perfusion measures in experimental acute respiratory distress syndrome, in the supine position, over injury progression and with increased PEEP. Further validation is needed to determine the accuracy of electrical impedance tomography in measuring perfusion redistributions after positional changes.


Respiratory Distress Syndrome , Tomography, X-Ray Computed , Male , Female , Swine , Animals , Electric Impedance , Respiratory Distress Syndrome/therapy , Lung , Perfusion , Tomography/methods
...