Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Kurume Med J ; 2024 Sep 06.
Article in English | MEDLINE | ID: mdl-39245570

ABSTRACT

Due to bicuspid aortic valve aortic stenosis, a 78-year-old man with a history of esophagectomy and presternal gastric tube reconstruction required aortic valve replacement (AVR). AVR with a bioprosthetic valve was performed through a right parasternal thoracotomy. Despite the unfavorable conditions for conventional median sternotomy, AVR was successfully performed through an alternate approach. The right parasternal approach was excellent for AVR in patients with presternal gastric tube reconstruction for esophageal cancer (EC).

2.
Kurume Med J ; 2024 Aug 05.
Article in English | MEDLINE | ID: mdl-39098030

ABSTRACT

A 59-year-old woman, who had a history of acute coronary syndrome (ACS) but without obstructive coronary lesions 2 years previously, presented with vertigo. MRI revealed a left cerebellar embolism. TEE detected a mobile aortic valve tumor, suggesting a papillary fibroelastoma (PFE). Reviewing previous echocardiograms, it was discovered that the tumor was present at the time of the ACS event. At surgery, the PFE was present on the right coronary cusp. When the aortic valve was opened, it was found that the tumor was obstructing the right coronary artery (RCA) ostium. ACS was probably caused by PFE's dynamic obstruction of the RCA ostium.

3.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38479833

ABSTRACT

OBJECTIVES: The Ross procedure represents an excellent treatment option in younger patients with aortic stenosis but is limited by poor availability of homografts. In this study, we investigated the hydrodynamic performance of 3 different types of right ventricular outflow tract replacement with pericardium or synthetic material. METHODS: Three different types of valved conduits were constructed using pericardium and/or synthetic material (Group PEPE: pericardial cusps and pericardial conduit, Group PEPR: pericardial cusps and Dacron conduit, Group PRPR: expanded polytetrafluoroethylene cusps and Dacron conduit). The conduits were designed according to the Ozaki method. Their hydrodynamic performance (effective orifice area, mean pressure gradient and leakage volume) were evaluated in a mock circulation loop at different hydrodynamic conditions. RESULTS: Hydrodynamic assessment showed significantly larger effective orifice area of PEPE and PEPR compared to PRPR under all conditions and there were no significant differences between PEPE and PEPR [for condition 2: PEPE 2.43 (2.35-2.54) cm2, PEPR: 2.42 (2.4-2.5) cm2, PRPR: 2.08 (1.97-2.21) cm2, adjusted pairwise comparisons: PEPE versus PEPR: P = 0.80, PEPE versus PRPR: P < 0.001, PEPR versus PRPR: P < 0.001]. Mean pressure gradient was significantly lower for PEPE and PEPR compared with PRPR, whereas no significant differences were seen between PEPE and PEPR. Leakage volume was significantly lower for PEPE and PEPR compared with PRPR under all conditions while leakage was similar between PEPE and PEPR. CONCLUSIONS: Pulmonary graft reconstruction with pericardium cusps showed superior hydrodynamic performance compared with polytetrafluoroethylene cusps. Our results suggest that it could be considered as an alternative substitute for right ventricular outflow tract replacement during the Ross procedure.


Subject(s)
Heart Valve Prosthesis , Ventricular Outflow Obstruction , Humans , Polyethylene Terephthalates , Blood Vessel Prosthesis , Prosthesis Design , Ventricular Outflow Obstruction/surgery , Polytetrafluoroethylene , Treatment Outcome , Retrospective Studies
4.
Open Heart ; 10(2)2023 09.
Article in English | MEDLINE | ID: mdl-37696617

ABSTRACT

INTRODUCTION: Drug therapy to reduce the regurgitation fraction (RF) of high-grade aortic regurgitation (AR) by increasing heart rate (HR) is generally recommended. However, chronic HR reduction in HFREF patients can significantly improve aortic compliance and thereby potentially decrease RF. To clarify these contrasts, we examined the influence of HR, aortic compliance and stroke volume (SV) on RF in an ex vivo porcine model of severe AR. METHODS: Experiments were performed on porcine ascending aorta with aortic valves (n=12). Compliance was varied by inserting a Dacron graft close to the aortic valve. Both tube systems were connected to a left heart simulator varying HR and SV. AR was accomplished by punching a 0.3 cm2 hole in one aortic cusp. Flow, RF, SV and aortic pressure were measured, aortic compliance with transoesophageal ultrasound probes. RESULTS: Compliance of the aorta was significantly reduced after Dacron graft insertion (0.55%±0.21%/mm Hg vs 0.01%±0.007%/mm Hg, p<0.001, respectively). With increasing HR, RF was significantly reduced in each steady state of the native aorta (HR 40 bpm: 88%±7% vs HR 120 bpm: 42%±10%; p<0.001), but Dacron tube did not affect RF (HR 40 bpm: 87%±8%; p=0.79; HR 120 bpm: 42%±3%; p=0.86). Increasing SV also reduced RF independent of the stiff Dacron graft. CONCLUSION: Aortic compliance did not affect AR in the ex vivo porcine model of AR. RF was significantly reduced with increasing HR and SV. These results affirm that HR lowering and negative inotropic drugs should be avoided to treat severe AR.


Subject(s)
Aortic Valve Insufficiency , Heart Failure , Humans , Swine , Animals , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Heart Rate , Stroke Volume , Polyethylene Terephthalates , Aorta/diagnostic imaging , Aorta/surgery
5.
Catheter Cardiovasc Interv ; 100(5): 841-849, 2022 11.
Article in English | MEDLINE | ID: mdl-36040748

ABSTRACT

OBJECTIVES: The aim of this study was to investigate the degree of functional improvement of a transcatheter heart valve (THV) for valve-in-valve after bioprosthetic valve fracture (BVF) of three small surgical aortic valve bioprostheses (SAVBP) using high-pressure balloon aortic valvuloplasty (HP-BAV) under standardized ex-vivo-conditions. METHODS: A THV 26 mm (Evolut R) and SAVBP 21 mm (Perimount Magna Ease, Trifecta, and Epic supra [n = 4] were used. Mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area (GOA), minimal internal diameter (MID), and pinwheeling index (PWI) were analyzed before and after HP-BAV of the SAVBP using a noncompliant balloon. Fracturing of the SAVBP was done before implantation of the THV and the balloon pressures at the point of fracture were recorded. RESULTS: The Magna Ease and Epic fractured at balloon pressures of 18 and 8 atm, respectively. The Trifecta did not fracture up to a balloon pressure of 30 atm but was dilated. HP-BAV led to increased THV expansion as evident by straightened coaptation lines of the Evolut R 26 mm with reduced PWI, increased MID, and increased GOA in all 21 mm SAVBP. Evolut R showed significantly lower MPG and higher EOA as ViV in all prostheses after HP-BAV (p < 0.001). MPG and EOA of Evolut R differed regarding the SAVBP. Evolut R presented the lowest MPG and highest EOA in Magna Ease and the highest MPG and lowest EOA in Epic supra. CONCLUSIONS: The degree of function improvement of the same THV as ViV after HP-BAV depends on the surgical valve model. Functional improvement can also be achieved without valve fracture.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Hydrodynamics , Prosthesis Design , Treatment Outcome , Balloon Valvuloplasty/adverse effects
6.
Eur J Cardiothorac Surg ; 62(4)2022 09 02.
Article in English | MEDLINE | ID: mdl-35993864

ABSTRACT

OBJECTIVES: Selection of a surgical aortic valve (SAV) bioprosthesis model for the treatment of aortic valve disease remains controversial. The aim of this study was to characterize the functional performance of 8 SAV models in a standardized in vitro setting. METHODS: The hydrodynamic performance of 8 SAVs with labelled size 21 mm (Avalus™, Hancock® II, Mosaic® Ultra™, Perimount®, Perimount® Magna Ease, Epic™ Supra, Trifecta™ GT; Freestyle®), was investigated in a pulse duplicator. Transvalvular pressure gradients and effective orifice area (EOA) were recorded. The geometrical orifice area and physical dimensions of the valves were determined, and new functional dimensions were introduced. RESULTS: Mean pressure gradient (MPG) and EOA differed significantly between the analysed SAVs. The Epic presented with the lowest EOA and highest MPG, while the Trifecta showed the highest EOA and the lowest MPG. We introduce a useful way to determine the minimal internal diameter and a new measure termed 'relative orifice area' to characterize a valve's performance. CONCLUSIONS: SAVs showed significant differences in their hydrodynamic performance despite the same label size. This finding was related to the construction of the valves. We introduce a new measure that characterizes the functional performance of a valve model and size for the treatment of an aortic annulus of a specific size. Our data emphasize that SAV selection should carefully be done using an individual patient approach and that future research is necessary to improve the current generation of SAVs.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Hemodynamics , Humans , Physical Functional Performance , Prosthesis Design
7.
Article in English | MEDLINE | ID: mdl-35895002

ABSTRACT

OBJECTIVES: We investigated the hydrodynamic performance and cusp kinematics of the Ozaki neocuspidized aortic valve in comparison with the native aortic and prosthetic valves in an ex vivo study. METHODS: Native aortic valves of swine hearts were replaced by aortic valve substitutes, and their hydrodynamic performance (effective orifice area and mean pressure gradient) was evaluated in a mock circulation under defined conditions. The following aortic valve substitutes were investigated: native aortic valve, Ozaki valve, Perimount Magna Ease, Trifecta and St. Jude Medical Masters. All prosthetic valves had a labelled size of 21 mm. RESULTS: The Ozaki valve and native aortic valve showed a similar and significantly larger orifice area than all investigated prosthetic valves particularly at high flow rates. There was no significant difference between the Ozaki valve and the native aortic valve. The native aortic valve and Ozaki valve showed a similar increase in orifice area with increasing flow through the valve while prosthetic valves showed a markedly weaker increase. Similarly, the native and Ozaki valve showed a similar increase in mPG with forward flow which was weaker than prosthetic valves. Cusp kinematics were similar between the native and Ozaki valve, whilst prosthetic valves were clearly distinguishable from them. CONCLUSIONS: The Ozaki procedure showed excellent hydrodynamic performance compared to prosthetic valves and showed similar cusp motion characteristics to the native aortic valve. Our results suggest that the Ozaki neocuspidized valve behaves physiologically in many aspects, which may contribute to beneficial clinical outcomes.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Animals , Aortic Valve/surgery , Hemodynamics , Hydrodynamics , Prosthesis Design , Swine
8.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Article in English | MEDLINE | ID: mdl-35380636

ABSTRACT

OBJECTIVES: Surgical aortic valve replacement (SAVR) in small annuli carries an elevated risk for the patient-prosthesis mismatch. In this study, we systematically investigated the influence of different implantation techniques including annular enlargement (AE) on the functional result after SAVR in small annuli using a standardized ex vivo model. METHODS: SAVR using the PERIMOUNT Magna Ease® (PME) 21 mm was performed in small porcine aortic roots using 4 implantation techniques: non-everting pledgeted (NE) suture, single interrupted (SI) suture, continuous suture (CS), figure-of-8 (F8) suture, as well as the PME 23 mm after AE using the Nunez method and the NE suture technique (PME23 AE). The effective orifice area (EOA), mean pressure gradient and leakage volume were evaluated using a mock circulation loop in accordance with ISO regulations. RESULTS: Experiments were conducted on 31 porcine aortic roots. PME21 using F8 and PME23 after AE achieved a significantly larger EOA than using NE. PME23 after AE showed a larger EOA than the PME21 using any suture technique, except the F8 [for stroke volume of 74 ml: PME21 NE: 1.68 (1.63-1.72) cm2, PME21 SI: 1.76 (1.68-1.81) cm2 (P = 0.17), PME21 CS: 1.76 (1.65-1.79) cm2 (P = 0.14), PME21 F8: 1.81 (1.70-1.85) cm2 (P = 0.005); PME23 AE: 1.83 (1.73-1.92) cm2 (P < 0.001)]. SI and CS did not result in larger EOA compared with the NE technique. PME21 using SI had a significantly larger leakage volume than using NE and there was no significant difference between other techniques [for stroke volume of 74 ml: PME21 NE: 3.51 (1.85-4.53) ml/stroke, PME21 SI: 6.00 (4.02-7.06) ml/stroke (P < 0.001), PME21 CS: 4.04 (3.60-4.49) ml/stroke (P = 0.10), PME21 F8: 3.16 (1.99-3.62) ml/stroke (P = 0.74), PME23 NE: 2.89 (2.45-4.72) ml/stroke (P = 0.51)]. CONCLUSIONS: The F8 technique with the PME21 achieved a similar EOA as the 1 size larger PME23 using NE after AE. These results suggest that the F8 technique may be an effective surgical modification to improve the haemodynamic result in a small annulus without additional AE.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Animals , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis Implantation/methods , Hemodynamics , Prosthesis Design , Suture Techniques , Swine
9.
Eur J Cardiothorac Surg ; 62(5)2022 10 04.
Article in English | MEDLINE | ID: mdl-35333318

ABSTRACT

OBJECTIVES: Transcatheter aortic valve-in-valve (ViV) procedures are increasingly performed for the treatment of degenerated surgical aortic valves with a high risk for a redo operation. For an optimal functional result, precise positioning of the transcatheter heart valve (THV) inside the SHV is crucial. The aim of this study was to systematically investigate the impact of implantation depth on the functional result after a ViV procedure in a standardized in vitro setting. METHODS: A THV 23 mm (Evolut PRO) and 3 SHV 21 mm (Perimount Magna Ease, Trifecta and Hancock II) were used for hydrodynamic testing with a constant heartbeat 64/min and a range of 55-105 ml of stroke volume in 5 different positions of the THV. The following parameters were analysed: mean pressure gradient (MPG), effective orifice area (EOA), geometric orifice area, minimal internal diameter and pin-wheeling index. RESULTS: MPG and EOA differed significantly regarding the position of the THV in the same SHV. The highest EOA and the lowest MPG were recorded for Evolut PRO with significance for both parameters in Hancock II at 4 vs 5 mm (P < 0.001), in Magna Ease at 2 mm (vs 3 mm and vs 6 mm, P < 0.001) and in Trifecta at 4 mm (vs 5 and 6 mm, P < 0.001). Leaflet coadaptation, minimal internal diameter and maximal geometric orifice area of the same TAV differ regarding the position of the TAV. CONCLUSIONS: The optimal position for hydrodynamic performance of the THV as ViV differs among specific SHV models. The findings may be useful for planning a ViV procedure using the Evolut PRO THV.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Hydrodynamics , Prosthesis Design , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Treatment Outcome
10.
Interact Cardiovasc Thorac Surg ; 33(4): 518-524, 2021 10 04.
Article in English | MEDLINE | ID: mdl-34089604

ABSTRACT

OBJECTIVES: We investigated the Ozaki procedure using a single interrupted suture technique (SST) and compared this with the standard continuous suture technique (CST) with regard to hydrodynamic valve performance. In addition, both techniques were compared with the native aortic valve (NAV). METHODS: Effective orifice area, mean pressure gradient and leakage volume were evaluated in the NAV as well as after an Ozaki procedure using SST or CST in fresh swine aortic roots using a mock circulation loop. The NAV, SST and CST were evaluated under 4 defined hydrodynamic conditions. RESULTS: Both suture techniques resulted in a similar effective orifice area under all conditions [for stroke volume of 70 ml: SST: 1.50 (1.35-1.87) vs CST: 1.57 (1.41-1.72) cm2, P = 0.8] and there were no significant differences between both suture techniques and the NAV (P > 0.05). Regarding mean pressure gradient, the Ozaki procedure with SST and CST showed no significant differences [7.23 (5.53-8.91) vs 7.04 (6.65-7.60) mmHg, P = 0.72] and there was no significant difference between both suture techniques and the NAV (P > 0.1). In leakage volume, there was no significant difference between SST and CST [4.49 (3.91-4.99) vs CST: 4.23 (3.58-4.87) ml/stroke, P = 0.34]. CONCLUSIONS: The Ozaki procedure with SST performed similarly to that with CST with regard to hydrodynamic performance. Our results suggest that the Ozaki procedure can be performed with SST instead of CST, which may be useful in patients with limited surgical exposure, such as a small annulus.


Subject(s)
Aortic Valve , Heart Valve Prosthesis , Animals , Aorta/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Humans , Stroke Volume , Suture Techniques , Swine
11.
Surg Case Rep ; 5(1): 125, 2019 Aug 05.
Article in English | MEDLINE | ID: mdl-31385066

ABSTRACT

BACKGROUND: Florida sleeve technique was reported by Hess et al. as a new technique of valve sparing aortic root replacement without the requirement of entire aortic root wall resection and coronary artery reconstruction. We present a rare case of an unruptured aneurysm of the right sinus of Valsalva that was successfully treated with resection of the aneurysm and the Florida sleeve technique. CASE PRESENTATION: A 72-year-old man was admitted for the treatment of an unruptured aneurysm of the right sinus of Valsalva. Computed tomography showed an aneurysm of the right sinus of Valsalva measuring > 40 mm and protruding into the right ventricular outflow tract. The aneurysm dilated up to 5 mm per year, and the left sinus of Valsalva and non-coronary sinus of Valsalva also showed dilation, and he underwent resection of only the right sinus of Valsalva aneurysm and valve sparing aortic root replacement with the Florida sleeve technique. CONCLUSIONS: We performed valve-sparing aortic root replacement with the Florida sleeve technique. It could reduce surgical risks and prevent a dilatation of the residual sinus of Valsalva through coverage with a graft for a long term.

12.
Interact Cardiovasc Thorac Surg ; 29(5): 800-802, 2019 11 01.
Article in English | MEDLINE | ID: mdl-31369121

ABSTRACT

In this article, we report on the case of an 85-year-old woman with a history of left pulmonary tuberculosis, who was referred for Stanford type A acute aortic dissection. A preoperative chest X-ray and computed tomography revealed extreme mediastinal deviation to the left. We decided to perform surgery with left rib-cross thoracotomy. This approach yielded excellent exposure of the aortic root, ascending aorta and aortic arch. Following an uneventful operative and postoperative course, the patient was discharged on the 21st postoperative day.


Subject(s)
Aorta/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation/methods , Mediastinitis/etiology , Thoracotomy/methods , Tuberculosis, Pulmonary/complications , Aged, 80 and over , Aortic Dissection/complications , Aortic Aneurysm, Thoracic/complications , Female , Humans , Mediastinitis/diagnosis , Radiography, Thoracic , Tomography, X-Ray Computed , Tuberculosis, Pulmonary/diagnosis
13.
Int Heart J ; 58(1): 144-146, 2017 Feb 07.
Article in English | MEDLINE | ID: mdl-28077818

ABSTRACT

We report progressive enlargement of the excluded left atrial appendage (LAA) with a thrombus in a patient who had undergone valve surgery and endocardial suture closure of the LAA previously. Echocardiography and CT detected no communication between the LAA and the left atrium. Magnetic resonance imaging showed the LAA was filled with fresh and old thrombi. Coronary arteriography demonstrated small left coronary artery-LAA fistulae. At surgery, successful exclusion of the LAA was confirmed after removal of the thrombi. Persistent inflow of blood through the coronary artery fistulae to the excluded LAA may be the primary mechanism of this pathology.


Subject(s)
Atrial Appendage/diagnostic imaging , Coronary Angiography , Coronary Thrombosis/diagnostic imaging , Postoperative Complications/diagnostic imaging , Aged , Coronary Thrombosis/etiology , Female , Humans , Magnetic Resonance Imaging , Postoperative Complications/etiology , Tomography, X-Ray Computed , Vascular Fistula/complications
14.
J Heart Valve Dis ; 25(4): 437-439, 2016 07.
Article in English | MEDLINE | ID: mdl-28009946

ABSTRACT

A 70-year-old woman with a history of aortic valve replacement and coronary artery bypass grafting (CABG) was transferred to the authors' hospital for further management of a three-month fever of unknown origin. Computed tomography showed a huge mass in the ascending aorta with pseudoaneurysm. Blood ß-D-glucan levels were significantly high, and blood culture showed the growth of Candida albicans. The fungus ball was excised surgically, together with aortic root replacement and CABG, followed by six-month postoperative anti-fungal therapy. Early diagnosis by imaging studies followed by aggressive surgery and long-term postoperative antifungal treatment should result in a favorable outcome.


Subject(s)
Aneurysm, False/microbiology , Aneurysm, False/surgery , Aorta/microbiology , Aorta/surgery , Candida albicans/isolation & purification , Candidiasis/diagnosis , Candidiasis/surgery , Aged , Aortic Valve Stenosis/surgery , Coronary Artery Bypass , Female , Heart Valve Prosthesis Implantation , Humans
15.
J Artif Organs ; 19(4): 408-410, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27165606

ABSTRACT

A 77-year-old woman who had undergone mitral valve replacement (MVR) with a 29 mm Hancock standard (H-S) bioprosthesis (Model 242) and tricuspid annuloplasty (Kay's method) at the age of 44 years was admitted urgently with acute heart failure. Echocardiography showed severe transvalvular leakage of the prosthesis and moderate tricuspid regurgitation. The patient underwent reMVR with a 29 mm Carpentier-Edwards Perimount Magna Mitral bioprosthesis and tricuspid annuloplasty with a 30 mm MC3 ring. The explanted bioprosthesis showed mild calcification and a tear in the leaflet, dehisced commissures and pannus overgrowth. To our knowledge there are no reports describing H-S valves that were still functioning over 30 years after implantation. Herein, we report a case of reMVR in a patient with an H-S valve that had been implanted 33 years previously.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency/etiology , Mitral Valve , Prosthesis Failure/adverse effects , Aged , Bioprosthesis , Calcinosis , Female , Heart Failure/etiology , Heart Failure/surgery , Humans , Mitral Valve Insufficiency/surgery , Reoperation , Tricuspid Valve/surgery
16.
Ann Thorac Cardiovasc Surg ; 21(4): 388-95, 2015.
Article in English | MEDLINE | ID: mdl-25740455

ABSTRACT

OBJECTIVES: In most patients with aortic regurgitation (AR), aortic valve replacement (AVR) improves left ventricular (LV) function, but some patients will not have favorable remodeling. Our objectives were to review long term clinical results of AVR for AR and to examine what factors affect the normalization of LV function after AVR for chronic AR. METHODS: Between 1989 and 2010, 177 patients underwent isolated AVR for chronic pure AR. The patients were divided into 2 groups based on indexed end-systolic LV diameter (iESD): Group L (iESD) ≥25 mm/m(2)) (130 patients) and Group S (iESD <25 mm/m(2)) (47 patients). RESULTS: There was no significant difference between groups in late mortality, freedom from cardiac-related death and rehospitalization for heart failure at late follow up after operation. At postoperative follow-up, 16% of patients had not recovered normal LV systolic function. By means of multivariate analysis, iESD and cardiac index (CI) were independent predictors of recovery of LV function and iESD >26.7 mm/m(2) and CI <2.71 l/min/m(2) were the best cut-off values. CONCLUSIONS: Early and late surgical results of AVR for chronic AR were good, but for the preservation of postoperative normal LV function, AVR for AR patients should be performed before iESD reaches 26.7 mm/m(2).


Subject(s)
Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/surgery , Stroke Volume , Transcatheter Aortic Valve Replacement , Ventricular Function, Left , Adult , Aged , Aged, 80 and over , Aortic Valve Insufficiency/mortality , Body Mass Index , Chronic Disease , Female , Follow-Up Studies , Heart Valve Prosthesis , Humans , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Risk Factors , Sensitivity and Specificity , Time Factors , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL