Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Braz J Cardiovasc Surg ; 39(4): e20230278, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748990

ABSTRACT

CLINICAL DATA: Female, seven years old, referred to our service complaining about congestive heart failure symptoms due to mitral valve regurgitation and atrial septal defect. Technical description: Echocardiographic findings compatible with Barlow's disease and atrial septal defect, ostium secundum type. OPERATION: She was submitted to mitral valvuloplasty with chordal shortening and prosthetic posterior ring (Gregori-Braile®) along with patch atrioseptoplasty. COMMENTS: Mitral valve regurgitation is a rare congenital heart disease and Barlow's disease is probably rarer. Mitral valve repair is the treatment of choice.


Subject(s)
Heart Septal Defects, Atrial , Mitral Valve Insufficiency , Humans , Heart Septal Defects, Atrial/surgery , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/complications , Female , Child , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Echocardiography , Mitral Valve Prolapse/surgery , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/complications
2.
Anal Chim Acta ; 1239: 340729, 2023 Jan 25.
Article in English | MEDLINE | ID: mdl-36628727

ABSTRACT

BACKGROUND: In this work, a novel analytical approach based on the photocatalytic decomposition of N-nitrosamines combined with headspace thin-film microextraction of the generated nitrogen oxides such as NO has been developed for the determination of the acyclic N-nitrosamine fraction in drinking water samples. A hydrophilic cellulose substrate modified with fluorescent silver nanoclusters (Ag NCs) was used both as extractant and sensing platform. A quenching effect of Ag NCs fluorescence occurs as the concentration of N-nitrosamines increases. Front-face fluorescence spectroscopy with a solid sample holder was employed for directly measuring the fluorescence quenching onto the cellulose substrate. RESULTS: In order to achieve an optimal analytical response, different parameters involved in the photocatalytic reaction as well as those concerning the microextraction step were fully investigated. It is demonstrated that the photodegradation rate of cyclic N-nitrosamines at acidic pH is much lower than that of acyclic ones, which can be the basis for the determination of the later fraction in waters. Under optimal conditions, a detection limit for the acyclic N-nitrosamine fraction around 0.08 µg L-1 using N-nitrosodimethylamine (NDMA) as model compound for calibration was obtained. Several drinking waters were spiked with acyclic N-nitrosamines showing recoveries in the range of 98-102% with a relative standard deviation of 3-4% (N = 3). SIGNIFICANCE AND NOVELTY: N-nitrosamines generated as by-products during disinfection processes applied to water cause multiple adverse effects on human health being classified as potential human carcinogens. This study highlights the suitability of a fluorescent paper-based sensor for the rapid analysis of the acyclic N-nitrosamine fraction (i.e. the most abundant fraction) as a total index in drinking water, being useful as screening tool before exhaustive chromatographic analysis, which saves costs, time and reduces waste generation.


Subject(s)
Drinking Water , Nitrosamines , Water Pollutants, Chemical , Humans , Nitrosamines/analysis , Drinking Water/analysis , Dimethylnitrosamine/analysis , Carcinogens , Disinfection/methods , Water Pollutants, Chemical/analysis
3.
J Vasc Bras ; 20: e20210163, 2021.
Article in English | MEDLINE | ID: mdl-35096034

ABSTRACT

Visceral artery aneurysms (VAAs) and visceral artery pseudoaneurysms (VAPAs) are rare conditions and are potentially lethal when they rupture. They are usually found as incidental findings on computed tomography (CT) scans of asymptomatic patients. Although conventional open surgery is currently considered the gold standard treatment, the endovascular approach has gained prominence as a minimally invasive procedure with lower surgical risk. In this approach, use of coil embolization in saccular VAAs and VAPAs and implantation of flow-modulating stents constitute alternative treatments for fusiform aneurysms. We present the case of a 51-year-old female patient complaining of acute abdominal pain, tachycardia, and hypotension, with evidence of abdominal bleeding on CT angiography, who was diagnosed with a ruptured ileocolic artery (ICA) pseudoaneurysm. She underwent early endovascular treatment for ICA embolization, which was successful and achieved clinical improvement.

SELECTION OF CITATIONS
SEARCH DETAIL
...