Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 143
Filter
2.
Article in English | MEDLINE | ID: mdl-38864808

ABSTRACT

BACKGROUND: Epicardial (Epi) access is commonly required during ventricular tachycardia ablation. Conventional Epi (ConvEpi) access targets a "dry" pericardial space presenting technical challenges and risk of complications. Recently, intentional puncture of coronary venous branches with Epi carbon dioxide insufflation (EpiCO2) has been described as a technique to improve Epi access. The safety of this technique relative to conventional methods remains unproven. OBJECTIVES: The authors sought to compare the feasibility and safety of EpiCO2 to ConvEpi access. METHODS: All patients at a high-volume center undergoing Epi access between January 2021 and December 2023 were included and grouped according to ConvEpi or EpiCO2 approach. Access technique was according to the discretion of the operator. RESULTS: Epi access was attempted in 153 cases by 17 different operators (80 ConvEpi vs 73 EpiCO2). There was no difference in success rate whether the ConvEpi or EpiCO2 approach was used (76 [95%] cases vs 67 [91.8%] cases; P = 0.4). Total Epi access time was shorter in the ConvEpi group compared with the EpiCO2 group (16.3 ± 11.6 minutes vs 26.9 ± 12.7 minutes; P < 0.001), though the total procedure duration was similar. Major Epi access-related complications occurred in only the ConvEpi group (6 [7.5%] ConvEpi vs 0 [0%] EpiCo2; P = 0.02). Bleeding ≥80 mL was more frequently observed following ConvEpi access (14 [17.5%] cases vs 4 [5.5%] cases; P = 0.02). After adjusting for age, repeat Epi access, and antithrombotic therapy, EpiCO2 was associated with a reduction in bleeding ≥80 mL (OR: 0.27; 95% CI: 0.08-0.89; P = 0.03). CONCLUSIONS: EpiCO2 access is associated with lower rates of major complication and bleeding when compared with ConvEpi access.

3.
Article in English | MEDLINE | ID: mdl-38924232

ABSTRACT

INTRODUCTION: Identifying the origin of nonpulmonary vein atrial fibrillation (AF) triggers (NPVTs) after pulmonary vein isolation (PVI) can be challenging. We aimed to determine if noninvasive electrocardiographic imaging (ECGi) could localize pacing from common NPVT sites. ECGi combines measured body surface potentials with heart-torso geometry acquired from computed tomography (CT) to generate an activation map. METHODS: In 12 patients with AF undergoing first time ablation, the ECGi vest was fitted for preprocedural CT scan and worn during the procedure. After PVI, we performed steady-state pacing from 15 typical anatomic NPVT sites at a cycle length of 700-800 ms. We co-registered the invasive anatomic map with the CT-based ECGi epicardial activation map to compare ECGi predicted to true pacing origin. RESULTS: In the study cohort (67% male, 58% persistent AF, and 67% with left atrial dilation), 148 (82%) pacing sites had both capture and adequate anatomy acquired from the three-dimensional mapping system to co-register with ECGi activation map. Median distance between true pacing sites and point of earliest epicardial activation derived from the ECGi maps for all sites was 17 mm (interquartile range, 10-22 mm). Assuming paced sites treated as regions with a radius of 2.5 cm, the earliest activation site on ECGi map falls within the region with 94% accuracy. CONCLUSION: ECGi can approximate the origin of paced beats from common NPVT sites to within a median distance of 17 mm. A rapidly identified region may then be the focus of more detailed catheter-based mapping techniques to facilitate successful localization and ablation of NPVTs.

4.
Heart Rhythm ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38762819

ABSTRACT

BACKGROUND: Conduction system pacing (CSP) by His bundle pacing or left bundle branch area pacing (LBBAP) is incorporated into Heart Rhythm Society guidelines for the management of bradycardia and cardiac resynchronization therapy. Despite increasing adoption with both lumenless leads and stylet-driven leads, concerns regarding the feasibility and safety of the extraction of CSP leads remain. OBJECTIVE: The aim of the study was to report on the safety, feasibility, and clinical outcomes of the extraction of CSP leads. METHODS: Patients undergoing the extraction of CSP leads from 10 international centers were enrolled in this retrospective study. Data regarding indications, lead location, lead type, extraction tools, procedural success, complications, and reimplantation in the conduction system were collected. RESULTS: Overall, 341 patients (age 69 ± 15 years; female 34%; cardiomyopathy 46%; lead dwell time 22 ± 26 months) underwent the extraction of 224 His bundle pacing and 117 LBBAP leads (lumenless leads 321; stylet-driven leads 20). Complete procedural success was achieved in 338 (99%), while clinical success was 100% with retained distal fragments in 3 patients (1%). Among patients with a lead dwell time of >6 months (6-193 months; n = 226), manual extraction was successful in 198 (87%), mechanical tools in 22 (10%), and laser in 6 (3%). Femoral tools were necessary in 3 patients. Minor complications occurred in 7 patients (2.1%). CSP reimplantation was successful in 233 of 244 patients attempted (95%). CONCLUSION: The overall success rates of the extraction of CSP leads were very high (although the LBBAP lead dwell time was <3 years), with a low need for extraction tools and minimal complication. Reimplantation in the conduction system is feasible and safe.

5.
Heart Rhythm ; 21(5): e1-e29, 2024 May.
Article in English | MEDLINE | ID: mdl-38466251

ABSTRACT

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Subject(s)
Consensus , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals , Humans , Cardiovascular Infections/diagnosis , Endocarditis/diagnosis , Endocarditis/diagnostic imaging , Fluorodeoxyglucose F18/pharmacology , Leukocytes , Multimodal Imaging/methods , Positron Emission Tomography Computed Tomography/methods , Radiopharmaceuticals/pharmacology , Single Photon Emission Computed Tomography Computed Tomography/methods , Societies, Medical , United States
6.
JACC Cardiovasc Imaging ; 17(6): 669-701, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38466252

ABSTRACT

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multisocietal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multifocal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Subject(s)
Consensus , Delphi Technique , Fluorodeoxyglucose F18 , Leukocytes , Positron Emission Tomography Computed Tomography , Predictive Value of Tests , Radiopharmaceuticals , Single Photon Emission Computed Tomography Computed Tomography , Humans , Fluorodeoxyglucose F18/administration & dosage , Radiopharmaceuticals/administration & dosage , Positron Emission Tomography Computed Tomography/standards , Single Photon Emission Computed Tomography Computed Tomography/standards , Prognosis , Prosthesis-Related Infections/diagnostic imaging , Reproducibility of Results , Endocarditis/diagnostic imaging , Cardiovascular Infections/diagnostic imaging , Algorithms
7.
J Nucl Cardiol ; 34: 101786, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38472038

ABSTRACT

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.


Subject(s)
Cardiovascular Infections , Endocarditis , Humans , Positron Emission Tomography Computed Tomography , Fluorodeoxyglucose F18 , Consensus , Tomography, X-Ray Computed , Multimodal Imaging , Endocarditis/diagnostic imaging , Tomography, Emission-Computed, Single-Photon
8.
Clin Infect Dis ; 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38466039

ABSTRACT

This document on cardiovascular infection, including infective endocarditis, is the first in the American Society of Nuclear Cardiology Imaging Indications (ASNC I2) series to assess the role of radionuclide imaging in the multimodality context for the evaluation of complex systemic diseases with multi-societal involvement including pertinent disciplines. A rigorous modified Delphi approach was used to determine consensus clinical indications, diagnostic criteria, and an algorithmic approach to diagnosis of cardiovascular infection including infective endocarditis. Cardiovascular infection incidence is increasing and is associated with high morbidity and mortality. Current strategies based on clinical criteria and an initial echocardiographic imaging approach are effective but often insufficient in complicated cardiovascular infection. Radionuclide imaging with 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/CT leukocyte scintigraphy can enhance the evaluation of suspected cardiovascular infection by increasing diagnostic accuracy, identifying extracardiac involvement, and assessing cardiac implanted device pockets, leads, and all portions of ventricular assist devices. This advanced imaging can aid in key medical and surgical considerations. Consensus diagnostic features include focal/multi-focal or diffuse heterogenous intense 18F-FDG uptake on valvular and prosthetic material, perivalvular areas, device pockets and leads, and ventricular assist device hardware persisting on non-attenuation corrected images. There are numerous clinical indications with a larger role in prosthetic valves, and cardiac devices particularly with possible infective endocarditis or in the setting of prior equivocal or non-diagnostic imaging. Illustrative cases incorporating these consensus recommendations provide additional clarification. Future research is necessary to refine application of these advanced imaging tools for surgical planning, to identify treatment response, and more.

9.
Heart Rhythm O2 ; 5(1): 34-40, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38312199

ABSTRACT

Background: Long-term rhythm monitoring to detect atrial fibrillation (AF) following a cryptogenic stroke (CS) is well established. However, the burden of organized atrial arrhythmias in this population is not well defined. Objective: The purpose of this study was to assess the incidence and risk factors for organized atrial arrhythmias in patients with CS. Methods: We evaluated all patients with CS who received an insertable cardiac monitor (ICM) between October 2014 and April 2020. All ICM transmissions categorized as AF, tachycardia, or bradycardia were reviewed. We evaluated the time to detection of organized AF and the combination of either organized atrial arrhythmia or AF. Results: A total of 195 CS patients with ICMs were included (51% men; mean age 66 ± 12 years; mean CHA2DS2-VASC score 4.6). Over mean follow-up of 18.9 ± 11.2 months, organized atrial arrhythmias lasting ≥30 seconds were detected in 45 patients (23%), of whom 62% did not have AF. Seventeen patients had both organized atrial arrhythmia and AF, and another 21 patients had AF only. Compared to those with normal left atrial size, patients with left atrial enlargement had a higher adjusted risk for development of atrial arrhythmias (mild left atrial enlargement: hazard ratio 1.99; 95% confidence interval 1.06-3.75; moderate/severe left atrial enlargement: hazard ratio 3.06; 95% confidence interval 1.58-5.92). Conclusion: Organized atrial arrhythmias lasting ≥30 seconds are detected in nearly one-fourth of CS patients. Two-thirds of these patients did not have AF. Further studies are required to evaluate the impact of organized atrial arrhythmias on recurrent stroke risk.

10.
Heart Rhythm ; 21(6): 806-811, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38296010

ABSTRACT

BACKGROUND: Targeting non-pulmonary vein triggers (NPVTs) after pulmonary vein isolation may reduce atrial fibrillation (AF) recurrence. Isoproterenol infusion and cardioversion of spontaneous or induced AF can provoke NPVTs but typically require vasopressor support and increased procedural time. OBJECTIVE: The purpose of this study was to identify risk factors for the presence of NPVTs and create a risk score to identify higher-risk subgroups. METHODS: Using the AF ablation registry at the Hospital of the University of Pennsylvania, we included consecutive patients who underwent AF ablation between January 2021 and December 2022. We excluded patients who did not receive NPVT provocation testing after failing to demonstrate spontaneous NPVTs. NPVTs were defined as non-pulmonary vein ectopic beats triggering AF or focal atrial tachycardia. We used risk factors associated with NPVTs with P <.1 in multivariable logistic regression model to create a risk score in a randomly split derivation set (80%) and tested its predictive accuracy in the validation set (20%). RESULTS: In 1530 AF ablations included, NPVTs were observed in 235 (15.4%). In the derivation set, female sex (odds ratio [OR] 1.40; 95% confidence interval [CI] 0.96-2.03; P = .080), sinus node dysfunction (OR 1.67; 95% CI 0.98-2.87; P = .060), previous AF ablation (OR 2.50; 95% CI 1.70-3.65; P <.001), and left atrial scar (OR 2.90; 95% CI 1.94-4.36; P <.001) were risk factors associated with NPVTs. The risk score created from these risk factors (PRE2SSS2 score; [PRE]vious ablation: 2 points, female [S]ex: 1 point, [S]inus node dysfunction: 1 point, left atrial [S]car: 2 points) had good predictive accuracy in the validation cohort (area under the receiver operating characteristic curve 0.728; 95% CI 0.648-0.807). CONCLUSION: A risk score incorporating predictors for NPVTs may allow provocation of triggers to be performed in patients with greatest expected yield.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/physiopathology , Atrial Fibrillation/etiology , Atrial Fibrillation/diagnosis , Female , Male , Pulmonary Veins/surgery , Middle Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Risk Factors , Risk Assessment/methods , Retrospective Studies , Aged , Registries , Heart Conduction System/physiopathology , Recurrence , Follow-Up Studies
11.
J Interv Card Electrophysiol ; 67(3): 559-569, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37592198

ABSTRACT

BACKGROUND: The use of a multi-electrode Optrell mapping catheter during ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation procedures has not been widely reported. OBJECTIVES: We aim to describe the feasibility and safety of using the Optrell multipolar mapping catheter (MPMC) to guide catheter ablation of VT and PVCs. METHODS: We conducted a single-center, retrospective evaluation of patients who underwent VT or PVC ablation between June and November 2022 utilizing the MPMC. RESULTS: A total of 20 patients met the inclusion criteria (13 VT and 7 PVC ablations, 80% male, 61 ± 15 years). High-density mapping was performed in the VT procedures with median 2753 points [IQR 1471-17,024] collected in the endocardium and 12,830 points [IQR 2319-30,010] in the epicardium. Operators noted challenges in manipulation of the MPMC in trabeculated endocardial regions or near valve apparatus. Late potentials (LPs) were detected in 11 cases, 7 of which had evidence of isochronal crowding demonstrated during late annotation mapping. Two patients who also underwent entrainment mapping had critical circuitry confirmed in regions of isochronal crowding. In the PVC group, high-density voltage and activation mapping was performed with a median 1058 points [IQR 534-3582] collected in the endocardium. CONCLUSIONS: This novel MPMC can be used safely and effectively to create high-density maps in LV endocardium or epicardium. Limitations of the catheter include a longer wait time for matrix formation prior to starting point collection and challenges in manipulation in certain regions.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Ventricular Premature Complexes , Humans , Male , Female , Retrospective Studies , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Ventricular Premature Complexes/surgery , Electrodes , Catheters , Catheter Ablation/methods
12.
J Interv Card Electrophysiol ; 67(3): 617-623, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37700118

ABSTRACT

BACKGROUND: There is growing interest in the possibility of discontinuing oral anticoagulation following successful catheter ablation of atrial fibrillation (AF). However, it remains unknown whether patients can accurately detect arrhythmia recurrences following ablation. We therefore sought to characterize the accuracy of pulse checking and arrhythmia symptoms for the identification of AF following ablation. METHODS: This prospective cohort study included patients at the Hospital of the University of Pennsylvania with an insertable cardiac monitor (ICM) treated with catheter ablation for AF who recorded the results from minimum twice daily pulse checks and additionally with arrhythmia symptoms into a diary for 2 months following their procedure. Accuracy of this self-assessment protocol was determined by comparison to ICM-detected AF. RESULTS: A total of 55 patients (age 69 ± 8 years, 30 (55%) male, CHA2DS2VASc score 3.2 ± 1. 5) were included. Patients recorded a total of 5911 pulse checks, and there were 280 episodes of ICM-documented AF among 26 patients with an average duration of 2.5 ± 3.3 h. Among 362 episodes of patient-suspected AF, 134 correlated with ICM-identified AF (37% true positive rate). Of the 5549 pulse checks that did not identify AF, 196 correlated with ICM-identified AF (4% false negative rate). Twice daily pulse checking had a sensitivity of 47% and a specificity of 96% for identifying each episode of AF. CONCLUSIONS: Our data indicate that a strategy of pulse checks and symptom assessment is insufficient to identify all episodes of AF in many patients following catheter ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Male , Middle Aged , Aged , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Prospective Studies , Electrocardiography, Ambulatory/methods , Heart Rate , Catheter Ablation/methods
15.
JACC Clin Electrophysiol ; 9(12): 2523-2533, 2023 12.
Article in English | MEDLINE | ID: mdl-37715743

ABSTRACT

BACKGROUND: Entrainment and pace mapping are used to identify critical components (CCs) of ventricular tachycardia (VT) circuits. In patients with dense myocardial scarring, VT circuits may elude capture at standard high pacing outputs (up to 10 mA at a 2-millisecond pulse width). OBJECTIVES: The purpose of this study was to assess the utility of very high-output pacing (V-HOP, 50 mA at 2 milliseconds) for identifying CCs of VT circuits after standard high pacing output failed to elicit capture in densely scarred myocardial tissue. METHODS: Our standard VT ablation approach included electroanatomic mapping for substrate characterization and entrainment and/or pace mapping to identify CCs of VT circuits. Patients that required V-HOP to capture sites of interest comprised the study cohort. Ablation endpoints were VT termination and noninducibility. RESULTS: Twenty-five patients (71 ± 10 years of age, all males) undergoing 26 VT ablations met the inclusion criteria. The mean left ventricular ejection fraction was 30% ± 14%, and 85% had ischemic cardiomyopathy. V-HOP was used to successfully entrain VT in 17 patients, yielding central isthmus sites in 10 and entrance/exit sites in 4. VT terminated with radiofrequency ablation at these sites in 15 patients. In 9 patients, V-HOP identified scar locations with a delayed exit. Acute procedural success was achieved in 24 patients without any adverse events. Over a follow-up period of 16 ± 21 months, 2 patients experienced VT recurrence requiring repeat ablation during which the same location was targeted successfully in 1 patient. CONCLUSIONS: In VT patients with a dense scar that is traditionally inexcitable, V-HOP can identify CCs of the re-entrant circuit and guide successful ablation.


Subject(s)
Myocardial Ischemia , Tachycardia, Ventricular , Male , Humans , Cicatrix , Stroke Volume , Ventricular Function, Left , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery
16.
JACC Clin Electrophysiol ; 9(11): 2275-2287, 2023 11.
Article in English | MEDLINE | ID: mdl-37737775

ABSTRACT

BACKGROUND: Targeting nonpulmonary vein triggers (NPVTs) of atrial fibrillation (AF) after pulmonary vein isolation can be challenging. NPVTs are often single ectopic beats with a surface P-wave obscured by a QRS or T-wave. OBJECTIVES: The goal of this study was to construct an algorithm to regionalize the site of origin of NPVTs using only intracardiac bipolar electrograms from 2 linear decapolar catheters positioned in the posterolateral right atrium (along the crista terminalis with the distal bipole pair in the superior vena cava) and in the proximal coronary sinus (CS). METHODS: After pulmonary vein isolation in 42 patients with AF, pacing from 15 typical anatomic NPVT sites was conducted. For each pacing site, the electrogram activation sequence was analyzed from the CS catheter (simultaneous/chevron/inverse chevron/distal-proximal/proximal-distal) and activation time (ie, CSCTAT) between the earliest electrograms from the 2 decapolar catheters was measured referencing the earliest CS electrogram; a negative CSCTAT value indicates the crista terminalis catheter electrogram was earlier, and a positive CSCTAT value indicates the CS catheter electrogram was earlier. A regionalization algorithm with high predictive value was defined and tested in a validation cohort with AF NPVTs localized with electroanatomic mapping. RESULTS: In the study patient cohort (71% male; 43% with persistent AF, 52% with left atrial dilation), the algorithm grouped with high precision (positive predictive value 81%-99%, specificity 94%-100%, and sensitivity 30%-94%) the 15 distinct pacing sites into 9 clinically useful regions. Algorithm testing in a 98 patient validation cohort showed predictive accuracy of 91%. CONCLUSIONS: An algorithm defined by the activation sequence and timing of electrograms from 2 linear multipolar catheters provided accurate regionalization of AF NPVTs to guide focused detailed mapping.


Subject(s)
Atrial Fibrillation , Vena Cava, Superior , Humans , Male , Female , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Heart Atria , Catheters , Algorithms
17.
Europace ; 25(11)2023 11 02.
Article in English | MEDLINE | ID: mdl-37772978

ABSTRACT

Clinically significant tricuspid regurgitation (TR) has historically been managed with either medical therapy or surgical interventions. More recently, percutaneous trans-catheter tricuspid valve (TV) replacement and tricuspid trans-catheter edge-to-edge repair have emerged as alternative treatment modalities. Patients with cardiac implantable electronic devices (CIEDs) have an increased incidence of TR. Severe TR in this population can occur for multiple reasons but most often results from the interactions between the CIED lead and the TV apparatus. Management decisions in patients with CIED leads and clinically significant TR, who are undergoing evaluation for a percutaneous TV intervention, need careful consideration as a trans-venous lead extraction (TLE) may both worsen and improve TR severity. Furthermore, given the potential risks of 'jailing' a CIED lead at the time of a percutaneous TV intervention (lead fracture and risk of subsequent infections), consideration should be given to performing a TLE prior to a percutaneous TV intervention. The purpose of this 'state-of-the-art' review is to provide an overview of the causes of TR in patients with CIEDs, discuss the available therapeutic options for patients with TR and CIED leads, and advocate for including a lead management specialist as a member of the 'heart team' when making treatment decisions in patients TR and CIED leads.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnosis , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/epidemiology , Cardiac Surgical Procedures/adverse effects , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Retrospective Studies
18.
JACC Clin Electrophysiol ; 9(9): 1903-1913, 2023 09.
Article in English | MEDLINE | ID: mdl-37480866

ABSTRACT

BACKGROUND: Intraprocedural identification of intramural septal substrate for ventricular tachycardia (ISS-VT) in nonischemic cardiomyopathy (NICM) is challenging. Delayed (>40 ms) transmural conduction time (DCT) with right ventricular basal septal pacing has been previously shown to identify ISS-VT. OBJECTIVES: This study sought to determine whether substrate catheter ablation incorporating areas of DCT may improve acute and long-term outcomes. METHODS: We included patients with NICM and ISS-VT referred for catheter ablation between 2016 and 2020. ISS-VT was defined by the following: 1) confluent septal areas of low unipolar voltage (<8.3 mV) in the presence of normal or minimal bipolar abnormalities; and 2) presence of abnormal electrograms in the septum. Substrate ablation was guided by the following: 1) activation and/or entrainment mapping for tolerated VT and pace mapping with ablation of abnormal septal electrograms for unmappable VTs (n = 57, Group 1); and 2) empirically extended to target areas of DCT during right ventricular basal septal pacing regardless of their participation in inducible VT(s) but sparing the conduction system when possible (n = 24, Group 2). RESULTS: There were no significant baseline differences between Groups 1 and 2. Noninducibility of any VT programmed stimulation at the end of ablation was higher in Group 2 compared with Group 1 (80% vs 53%; P = 0.03). At 12-month follow-up, single-procedure VT-free survival was significantly higher (79% vs 46%; P = 0.006) and the time to VT recurrence was longer (mean 10 ± 3 months vs 7 ± 4 months; P = 0.02) in Group 2 compared with Group 1. CONCLUSIONS: In patients with NICM and ISS-VT, a substrate ablation strategy that incorporates areas of DCT appears to improve freedom from recurrent VT.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/surgery , Cardiac Conduction System Disease , Heart Conduction System/surgery , Heart Ventricles
19.
Circ Arrhythm Electrophysiol ; 16(8): 468-474, 2023 08.
Article in English | MEDLINE | ID: mdl-37485688

ABSTRACT

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICDs) are an attractive alternative to transvenous ICDs among those not requiring pacing. However, the risks of damage to the S-ICD electrode during sternotomy and adverse interactions with sternal wires remain unclear. We sought to determine the rates of damage to the S-ICD lead during sternotomy, inappropriate shocks from electrical noise due to interaction with sternal wires, and failure to terminate spontaneous or induced ventricular arrhythmias. METHODS: Retrospective, multicenter study of patients undergoing sternotomy before or after S-ICD implantation. Clinical, procedural, and device-related data were collected by each center and analyzed by the coordinating center. These data were compared with a historical control cohort of nonsternotomy patients. RESULTS: Of 196 identified patients (52±16 years, 47 women), 166 underwent S-ICD implantation after sternotomy and 30 sternotomy after S-ICD. There was no damage to any lead among those who underwent sternotomy after S-ICD. Defibrillation threshold testing was performed in 63% at implant, with 91% first shock success. During a median follow-up of 29 months (range, 1-188), S-ICD first shocks successfully terminated spontaneous ventricular arrhythmias in 31 of 32 patients (97%). Inappropriate shocks occurred in 22 patients, most commonly related to T wave oversensing (n=14). Compared with the nonsternotomy controls, there were no differences in rates of first shock success for induced or spontaneous arrhythmias or rate of inappropriate shocks. CONCLUSIONS: Sternotomy before or after S-ICD does not confer additional risk relative to a historical control group without sternotomy.


Subject(s)
Defibrillators, Implantable , Humans , Female , Defibrillators, Implantable/adverse effects , Sternotomy/adverse effects , Retrospective Studies , Treatment Outcome , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control
SELECTION OF CITATIONS
SEARCH DETAIL
...