Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 198
Filter
1.
Ann Vasc Surg ; 2024 Aug 02.
Article in English | MEDLINE | ID: mdl-39098724

ABSTRACT

OBJECTIVES: This study aimed to assess geometry changes of the ascending aorta after thoracic endovascular aortic repair (TEVAR) for descending aortic dissection and identify potential risk factors for diameter and length change. METHODS: Between 04/2009 and 07/2021, 102 patients were treated for acute descending aortic dissections (Type B and non-A non-B) with TEVAR and were included in this analysis. Computed tomography angiographic scans were transferred to a dedicated imaging software and detailed aortic measurements (including length, diameter and area) were taken in multiplanar reconstruction postoperatively, after six months and annually thereafter. RESULTS: Sixty-five (58%) patients were male, with a mean age of 66 (±11). Four (4%) patients were diagnosed with a connective tissue disease. Before TEVAR, 79% of our patients were treated with a mean of 1.5 (±1.2) different classes of antihypertensive medications. This number rose to 98% after TEVAR and 2.7 (±1.0) different antihypertensive drugs. There was no significant change in length, diameter, cross-sectional area, or volume of the ascending aorta during the follow-up of 3 years after TEVAR. Body height was a negative predictor for mean ascending aortic diameter (p-value = -0.013; B = -8.890) and mean aortic diameter at the level of the brachiocephalic trunk (p-value = 0.039; B = -14.763). CONCLUSIONS: Our data suggests no significant changes in the ascending aorta following TEVAR of the descending thoracic aorta during mid-term follow-up when under stringent blood pressure medication. Additionally, we did not find any modifiable risk factors for geometry parameter increase.

2.
Nutr Metab (Lond) ; 21(1): 45, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38982517

ABSTRACT

BACKGROUND: Obesity is associated with alterations in the hypothalamic-pituitary-adrenal (HPA) axis. Effects of glucocorticoids on adipose tissues appear to depend on the specific adipose depot, in which they take place. In this study, we aimed to investigate the role of MRI-based adrenal gland volume as an imaging marker in association with different adipose tissue compartments. METHODS: The study cohort derives from the population-based research platform KORA (Cooperative Health Research in the Augsburg Region, Germany) MRI sub-study, a cross-sectional sub-study investigating the interactions between subclinical metabolic changes and cardiovascular disease in a study sample of 400 participants. Originally, eligible subjects underwent a whole-body MRI. MRI-based segmentations were performed manually and semi-automatically for adrenal gland volume, visceral adipose tissue (VAT), subcutaneous adipose tissue (SAT), epi- and pericardial fat and renal sinus fat. Hepatic and pancreatic lipid content were measured as pancreatic proton density fraction (PDFF) and MR-spectroscopic hepatic fat fraction (HFF). Multivariable linear regression analyses were performed. RESULTS: A number of 307 participants (56.2 ± 9.1 years, 60.3% male, 14.3% with type 2 diabetes (T2DM), 30.6% with obesity, 34.2% with hypertension) were included. In multivariable analyses, strong positive associations between adrenal gland volume and VAT, total adipose tissue (TAT) as well as HFF persisted after extensive step-wise adjustment for possible metabolic confounders (VAT: beta = 0.31, 95%-CI [0.71, 0.81], p < 0.001; TAT: beta = 0.14, 95%-CI [0.06, 0.23], p < 0.001; HFF: beta = 1.17, 95%-CI [1.04, 1.31], p = 0.009). In contrast, associations between adrenal gland volume and SAT were attenuated in multivariate analysis after adjusting for BMI. Associations between pancreatic PDFF, epi- and pericardial fat and renal sinus fat were mediated to a great extent by VAT (pancreatic PDFF: 72%, epicardial adipose tissue: 100%, pericardial adipose tissue: 100%, renal sinus fat: 81.5%). CONCLUSION: Our results found MRI-based adrenal gland volume as a possible imaging biomarker of unfavorable adipose tissue distribution, irrespective of metabolic risk factors. Thus, adrenal gland volume may serve as a potential MRI-based biomarker of metabolic changes and contributes to an individual characterization of metabolic states and individual risk stratification. Future studies should elucidate in a longitudinal study design, if and how HPA axis activation may trigger unfavorable adipose tissue distribution and whether and to which extent this is involved in the pathogenesis of manifest metabolic syndrome.

3.
Clin Res Cardiol ; 2024 Jul 30.
Article in English | MEDLINE | ID: mdl-39080016

ABSTRACT

AIM: To evaluate the effects of lipid-lowering medications of different intensities on total, calcified, and non-calcified plaque volumes in patients undergoing serial cardiac computed tomography angiography (CCTA). METHODS: Individuals with chronic coronary syndromes from 11 centers were included in a retrospective registry. Total, calcified, and non-calcified plaque volumes were quantified and the relative difference in plaque volumes between baseline and follow-up CCTA was calculated. The intensity of lipid-lowering treatment was designated as low, moderate, or high, based on current recommendations. RESULTS: Of 216 patients (mean age 63.1 ± 9.7 years), undergoing serial CCTA (median timespan = 824.5 [IQR = 463.0-1323.0] days), 89 (41.2%) received no or low-intensity lipid-lowering medications, and 80 (37.0%) and 47 (21.8%) moderate- and high-intensity lipid-lowering agents, respectively. Progression of total and non-calcified plaque was attenuated in patients on moderate-/high- versus those on no/low-intensity treatment and arrested in patients treated with high-intensity statins or PCSK9 inhibitors (p < 0.001). Halted increase of non-calcified plaque was associated with LDL-cholesterol reduction (p < 0.001), whereas calcified plaque mass and Agatston score increased irrespective of the lipid-lowering treatment (p = NS). The intensity of lipid-lowering therapy robustly predicted attenuation of non-calcified plaque progression as a function of the time duration between the two CCTA scans, and this was independent of age and cardiovascular risk factors (HR = 3.83, 95% CI = 1.81-8.05, p < 0.001). CONCLUSION: The LOCATE multi-center observational study shows that progression of non-calcified plaques, which have been previously described as precursors of acute coronary syndromes, can be attenuated with moderate-intensity, and arrested with high-intensity lipid-lowering therapy. GERMAN CLINICAL TRIALS REGISTER: DRKS00031954.

4.
Article in English | MEDLINE | ID: mdl-39009381

ABSTRACT

BACKGROUND: There is increasing evidence that myosteatosis, which is currently not assessed in clinical routine, plays an important role in risk estimation in individuals with impaired glucose metabolism, as it is associated with the progression of insulin resistance. With advances in artificial intelligence, automated and accurate algorithms have become feasible to fill this gap. METHODS: In this retrospective study, we developed and tested a fully automated deep learning model using data from two prospective cohort studies (German National Cohort [NAKO] and Cooperative Health Research in the Region of Augsburg [KORA]) to quantify myosteatosis on whole-body T1-weighted Dixon magnetic resonance imaging as (1) intramuscular adipose tissue (IMAT; the current standard) and (2) quantitative skeletal muscle (SM) fat fraction (SMFF). Subsequently, we investigated the two measures for their discrimination of and association with impaired glucose metabolism beyond baseline demographics (age, sex and body mass index [BMI]) and cardiometabolic risk factors (lipid panel, systolic blood pressure, smoking status and alcohol consumption) in asymptomatic individuals from the KORA study. Impaired glucose metabolism was defined as impaired fasting glucose or impaired glucose tolerance (140-200 mg/dL) or prevalent diabetes mellitus. RESULTS: Model performance was high, with Dice coefficients of ≥0.81 for IMAT and ≥0.91 for SM in the internal (NAKO) and external (KORA) testing sets. In the target population (380 KORA participants: mean age of 53.6 ± 9.2 years, BMI of 28.2 ± 4.9 kg/m2, 57.4% male), individuals with impaired glucose metabolism (n = 146; 38.4%) were older and more likely men and showed a higher cardiometabolic risk profile, higher IMAT (4.5 ± 2.2% vs. 3.9 ± 1.7%) and higher SMFF (22.0 ± 4.7% vs. 18.9 ± 3.9%) compared to normoglycaemic controls (all P ≤ 0.005). SMFF showed better discrimination for impaired glucose metabolism than IMAT (area under the receiver operating characteristic curve [AUC] 0.693 vs. 0.582, 95% confidence interval [CI] [0.06-0.16]; P < 0.001) but was not significantly different from BMI (AUC 0.733 vs. 0.693, 95% CI [-0.09 to 0.01]; P = 0.15). In univariable logistic regression, IMAT (odds ratio [OR] = 1.18, 95% CI [1.06-1.32]; P = 0.004) and SMFF (OR = 1.19, 95% CI [1.13-1.26]; P < 0.001) were associated with a higher risk of impaired glucose metabolism. This signal remained robust after multivariable adjustment for baseline demographics and cardiometabolic risk factors for SMFF (OR = 1.10, 95% CI [1.01-1.19]; P = 0.028) but not for IMAT (OR = 1.14, 95% CI [0.97-1.33]; P = 0.11). CONCLUSIONS: Quantitative SMFF, but not IMAT, is an independent predictor of impaired glucose metabolism, and discrimination is not significantly different from BMI, making it a promising alternative for the currently established approach. Automated methods such as the proposed model may provide a feasible option for opportunistic screening of myosteatosis and, thus, a low-cost personalized risk assessment solution.

5.
Sci Rep ; 14(1): 14664, 2024 06 25.
Article in English | MEDLINE | ID: mdl-38918570

ABSTRACT

Aim of this study was to analyse the associations of cardiovascular health and adrenal gland volume as a rather new imaging biomarker of chronic hypothalamic-pituitary-adrenal (HPA) axis activation. The study population originates from the KORA population-based cross-sectional prospective cohort. 400 participants without known cardiovascular disease underwent a whole-body MRI. Manual segmentation of adrenal glands was performed on VIBE-Dixon gradient-echo sequence. MRI based evaluation of cardiac parameters was achieved semi-automatically. Cardiometabolic risk factors were obtained through standardized interviews and medical examination. Univariate and multivariate associations were derived. Bi-directional causal mediation analysis was performed. 351 participants were eligible for analysis (56 ± 9.1 years, male 58.7%). In multivariate analysis, significant associations were observed between adrenal gland volume and hypertension (outcome hypertension: Odds Ratio = 1.11, 95% CI [1.01, 1.21], p = 0.028), left ventricular remodelling index (LVRI) (outcome LVRI: ß = 0.01, 95% CI [0.00, 0.02], p = 0.011), and left ventricular (LV) wall thickness (outcome LV wall thickness: ß = 0.06, 95% CI [0.02, 0.09], p = 0.005). In bi-directional causal mediation analysis adrenal gland volume had a borderline significant mediating effect on the association between hypertension and LVRI (p = 0.052) as well as wall thickness (p = 0.054). MRI-based assessment of adrenal gland enlargement is associated with hypertension and LV remodelling. Adrenal gland volume may serve as an indirect cardiovascular imaging biomarker.


Subject(s)
Adrenal Glands , Cardiovascular Diseases , Magnetic Resonance Imaging , Humans , Male , Middle Aged , Adrenal Glands/diagnostic imaging , Adrenal Glands/pathology , Magnetic Resonance Imaging/methods , Female , Cardiovascular Diseases/diagnostic imaging , Cross-Sectional Studies , Aged , Prospective Studies , Hypertension/diagnostic imaging , Hypertension/pathology , Ventricular Remodeling , Organ Size , Hypothalamo-Hypophyseal System/diagnostic imaging , Pituitary-Adrenal System/diagnostic imaging
6.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38837348

ABSTRACT

OBJECTIVES: To assess the accuracy of a deep learning-based algorithm for fully automated detection of thoracic aortic calcifications in chest computed tomography (CT) with a focus on the aortic clamping zone. METHODS: We retrospectively included 100 chest CT scans from 91 patients who were examined on second- or third-generation dual-source scanners. Subsamples comprised 47 scans with an electrocardiogram-gated aortic angiography and 53 unenhanced scans. A deep learning model performed aortic landmark detection and aorta segmentation to derive 8 vessel segments. Associated calcifications were detected and their volumes measured using a mean-based density thresholding. Algorithm parameters (calcium cluster size threshold, aortic mask dilatation) were varied to determine optimal performance for the upper ascending aorta that encompasses the aortic clamping zone. A binary visual rating served as a reference. Standard estimates of diagnostic accuracy and inter-rater agreement using Cohen's Kappa were calculated. RESULTS: Thoracic aortic calcifications were observed in 74% of patients with a prevalence of 27-70% by aorta segment. Using different parameter combinations, the algorithm provided binary ratings for all scans and segments. The best performing parameter combination for the presence of calcifications in the aortic clamping zone yielded a sensitivity of 93% and a specificity of 82%, with an area under the receiver operating characteristic curve of 0.874. Using these parameters, the inter-rater agreement ranged from κ 0.66 to 0.92 per segment. CONCLUSIONS: Fully automated segmental detection of thoracic aortic calcifications in chest CT performs with high accuracy. This includes the critical preoperative assessment of the aortic clamping zone.


Subject(s)
Aorta, Thoracic , Aortic Diseases , Deep Learning , Tomography, X-Ray Computed , Vascular Calcification , Humans , Aorta, Thoracic/diagnostic imaging , Retrospective Studies , Female , Male , Vascular Calcification/diagnostic imaging , Aged , Middle Aged , Tomography, X-Ray Computed/methods , Aortic Diseases/diagnostic imaging , Algorithms , Aged, 80 and over
8.
Insights Imaging ; 15(1): 124, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38825600

ABSTRACT

OBJECTIVES: Achieving a consensus on a definition for different aspects of radiomics workflows to support their translation into clinical usage. Furthermore, to assess the perspective of experts on important challenges for a successful clinical workflow implementation. MATERIALS AND METHODS: The consensus was achieved by a multi-stage process. Stage 1 comprised a definition screening, a retrospective analysis with semantic mapping of terms found in 22 workflow definitions, and the compilation of an initial baseline definition. Stages 2 and 3 consisted of a Delphi process with over 45 experts hailing from sites participating in the German Research Foundation (DFG) Priority Program 2177. Stage 2 aimed to achieve a broad consensus for a definition proposal, while stage 3 identified the importance of translational challenges. RESULTS: Workflow definitions from 22 publications (published 2012-2020) were analyzed. Sixty-nine definition terms were extracted, mapped, and semantic ambiguities (e.g., homonymous and synonymous terms) were identified and resolved. The consensus definition was developed via a Delphi process. The final definition comprising seven phases and 37 aspects reached a high overall consensus (> 89% of experts "agree" or "strongly agree"). Two aspects reached no strong consensus. In addition, the Delphi process identified and characterized from the participating experts' perspective the ten most important challenges in radiomics workflows. CONCLUSION: To overcome semantic inconsistencies between existing definitions and offer a well-defined, broad, referenceable terminology, a consensus workflow definition for radiomics-based setups and a terms mapping to existing literature was compiled. Moreover, the most relevant challenges towards clinical application were characterized. CRITICAL RELEVANCE STATEMENT: Lack of standardization represents one major obstacle to successful clinical translation of radiomics. Here, we report a consensus workflow definition on different aspects of radiomics studies and highlight important challenges to advance the clinical adoption of radiomics. KEY POINTS: Published radiomics workflow terminologies are inconsistent, hindering standardization and translation. A consensus radiomics workflow definition proposal with high agreement was developed. Publicly available result resources for further exploitation by the scientific community.

9.
Clin Exp Med ; 24(1): 103, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38758248

ABSTRACT

COVID-19 vaccination has been shown to prevent and reduce the severity of COVID-19 disease. The aim of this study was to explore the cardioprotective effect of COVID-19 vaccination in hospitalized COVID-19 patients. In this retrospective, single-center cohort study, we included hospitalized COVID-19 patients with confirmed vaccination status from July 2021 to February 2022. We assessed outcomes such as acute cardiac events and cardiac biomarker levels through clinical and laboratory data. Our analysis covered 167 patients (69% male, mean age 58 years, 42% being fully vaccinated). After adjustment for confounders, vaccinated hospitalized COVID-19 patients displayed a reduced relative risk for acute cardiac events (RR: 0.33, 95% CI [0.07; 0.75]) and showed diminished troponin T levels (Cohen's d: - 0.52, 95% CI [- 1.01; - 0.14]), compared to their non-vaccinated peers. Type 2 diabetes (OR: 2.99, 95% CI [1.22; 7.35]) and existing cardiac diseases (OR: 4.31, 95% CI [1.83; 10.74]) were identified as significant risk factors for the emergence of acute cardiac events. Our findings suggest that COVID-19 vaccination may confer both direct and indirect cardioprotective effects in hospitalized COVID-19 patients.


Subject(s)
COVID-19 Vaccines , COVID-19 , Hospitalization , SARS-CoV-2 , Humans , COVID-19/prevention & control , Male , Female , Middle Aged , Retrospective Studies , COVID-19 Vaccines/administration & dosage , COVID-19 Vaccines/immunology , Aged , Hospitalization/statistics & numerical data , SARS-CoV-2/immunology , Vaccination , Heart Diseases/prevention & control , Risk Factors , Adult , Troponin T/blood
10.
J Clin Med ; 13(8)2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38673658

ABSTRACT

Background: The goal of our study is to evaluate a method to quantify aortic valve calcification (AVC) in contrast-enhanced computed tomography for patients with suspected severe aortic stenosis pre-interventionally. Methods: A total of sixty-five patients with aortic stenosis underwent both a native and a contrast-enhanced computed tomography (CECT) scan of the aortic valve (45 in the training cohort and 20 in the validation cohort) using a standardized protocol. Aortic valve calcification was semi-automatically quantified via the Agatston score method for the native scans and was used as a reference. For contrast-enhanced computed tomography, a calcium threshold of the Hounsfield units of the aorta plus four times the standard deviation was used. Results: For the quantification of aortic valve calcification in contrast-enhanced computed tomography, a conversion formula (691 + 1.83 x AVCCECT) was derived via a linear regression model in the training cohort. The validation in the second cohort showed high agreement for this conversion formula with no significant proportional bias (Bland-Altman, p = 0.055) and with an intraclass correlation coefficient in the validation cohort of 0.915 (confidence interval 95% 0.786-0.966) p < 0.001. Conclusions: Calcium scoring in patients with aortic valve stenosis can be performed using contrast-enhanced computed tomography with high validity. Using a conversion factor led to an excellent agreement, thereby obviating an additional native computed tomography scan. This might contribute to a decrease in radiation exposure.

11.
Biomark Res ; 12(1): 31, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38444025

ABSTRACT

BACKGROUND: Changes in serum metabolites in individuals with altered cardiac function and morphology may exhibit information about cardiovascular disease (CVD) pathway dysregulations and potential CVD risk factors. We aimed to explore associations of cardiac function and morphology, evaluated using magnetic resonance imaging (MRI) with a large panel of serum metabolites. METHODS: Cross-sectional data from CVD-free individuals from the population-based KORA cohort were analyzed. Associations between 3T-MRI-derived left ventricular (LV) function and morphology parameters (e.g., volumes, filling rates, wall thickness) and markers of carotid plaque with metabolite profile clusters and single metabolites as outcomes were assessed by adjusted multinomial logistic regression and linear regression models. RESULTS: In 360 individuals (mean age 56.3 years; 41.9% female), 146 serum metabolites clustered into three distinct profiles that reflected high-, intermediate- and low-CVD risk. Higher stroke volume (relative risk ratio (RRR): 0.53, 95%-CI [0.37; 0.76], p-value < 0.001) and early diastolic filling rate (RRR: 0.51, 95%-CI [0.37; 0.71], p-value < 0.001) were most strongly protectively associated against the high-risk profile compared to the low-risk profile after adjusting for traditional CVD risk factors. Moreover, imaging markers were associated with 10 metabolites in linear regression. Notably, negative associations of stroke volume and early diastolic filling rate with acylcarnitine C5, and positive association of function parameters with lysophosphatidylcholines, diacylphosphatidylcholines, and acylalkylphosphatidylcholines were observed. Furthermore, there was a negative association of LV wall thickness with alanine, creatinine, and symmetric dimethylarginine. We found no significant associations with carotid plaque. CONCLUSIONS: Serum metabolite signatures are associated with cardiac function and morphology even in individuals without a clinical indication of CVD.

12.
Dtsch Arztebl Int ; 121(9): 284-290, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38530931

ABSTRACT

BACKGROUND: Population-wide research on potential new imaging biomarkers of the kidney depends on accurate automated segmentation of the kidney and its compartments (cortex, medulla, and sinus). METHODS: We developed a robust deep-learning framework for kidney (sub-)segmentation based on a hierarchical, three-dimensional convolutional neural network (CNN) that was optimized for multiscale problems of combined localization and segmentation. We applied the CNN to abdominal magnetic resonance images from the population-based German National Cohort (NAKO) study. RESULTS: There was good to excellent agreement between the model predictions and manual segmentations. The median values for the body-surface normalized total kidney, cortex, medulla, and sinus volumes of 9934 persons were 158, 115, 43, and 24 mL/m2. Distributions of these markers are provided both for the overall study population and for a subgroup of persons without kidney disease or any associated conditions. Multivariable adjusted regression analyses revealed that diabetes, male sex, and a higher estimated glomerular filtration rate (eGFR) are important predictors of higher total and cortical volumes. Each increase of eGFR by one unit (i.e., 1 mL/min per 1.73 m2 body surface area) was associated with a 0.98 mL/m2 increase in total kidney volume, and this association was significant. Volumes were lower in persons with eGFR-defined chronic kidney disease. CONCLUSION: The extraction of image-based biomarkers through CNN-based renal sub-segmentation using data from a population-based study yields reliable results, forming a solid foundation for future investigations.


Subject(s)
Kidney , Magnetic Resonance Imaging , Humans , Male , Female , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/statistics & numerical data , Kidney/diagnostic imaging , Middle Aged , Aged , Adult , Germany , Glomerular Filtration Rate/physiology , Biomarkers/analysis , Neural Networks, Computer , Deep Learning , Cohort Studies
15.
Int J Cardiovasc Imaging ; 40(4): 811-820, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38360986

ABSTRACT

To compare the diagnostic value of ultrahigh-resolution CT-angiography (UHR-CTA) compared with high-pitch spiral CTA (HPS-CTA) using a first-generation, dual-source photon-counting CT (PCD-CT) scanner for preprocedural planning of transcatheter aortic valve replacement (TAVR). Clinically referred patients with severe aortic valve stenosis underwent both, retrospective ECG-gated cardiac UHR-CTA (collimation: 120 × 0.2 mm) and prospective ECG-triggered aortoiliac HPS-CTA (collimation: 144 × 0.4 mm, full spectral capabilities) for TAVR planning from August 2022 to March 2023. Radiation dose was extracted from the CT reports, and the effective dose was calculated. Two radiologists analyzed UHR-CTA and HPS-CTA datasets, assessing the image quality of the aortic annulus, with regard to the lumen visibility and margin delineation using a 4-point visual-grading scale (ranges: 4 = "excellent" to 1 = "poor"). Aortic annulus area (AAA) measurements were taken for valve prosthesis sizing, with retrospective UHR-CTA serving as reference standard. A total of 64 patients were included (mean age, 81 years ± 7 SD; 28 women) in this retrospective study. HPS-CTA showed a lower radiation dose, 4.1 mSv vs. 12.6 mSv (p < 0.001). UHR-CTA demonstrated higher image quality to HPS-CTA (median score, 4 [IQR, 3-4] vs. 3 [IQR, 2-3]; p < 0.001). Quantitative assessments of AAA from both CTA datasets were strongly positively correlated (mean 477.4 ± 91.1 mm2 on UHR-CTA and mean 476.5 ± 90.4 mm2 on HPS-CTA, Pearson r2 = 0.857, p < 0.001) with a mean error of 22.3 ± 24.6 mm2 and resulted in identical valve prosthesis sizing in the majority of patients (91%). Patients with lower image quality on HPS-CTA (score value 1 or 2, n = 28) were more likely to receive different sizing recommendations (82%). Both UHR-CTA and HPS-CTA acquisitions using photon-counting CT technology provided reliable aortic annular assessments for TAVR planning. While UHR-CTA offers superior image quality, HPS-CTA is associated with lower radiation exposure. However, severely impaired image quality on HPS-CTA may impact on prosthesis sizing, suggesting that immediate post-scan image evaluations may require complementary UHR-CTA scanning.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Cardiac-Gated Imaging Techniques , Computed Tomography Angiography , Electrocardiography , Heart Valve Prosthesis , Predictive Value of Tests , Prosthesis Design , Radiation Dosage , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Female , Male , Retrospective Studies , Aged, 80 and over , Aged , Transcatheter Aortic Valve Replacement/instrumentation , Reproducibility of Results , Severity of Illness Index , Radiation Exposure , Clinical Decision-Making , Photons , Multidetector Computed Tomography
16.
Eur J Radiol ; 173: 111360, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38342061

ABSTRACT

PURPOSE: To determine the diagnostic accuracy of volumetric interpolated breath-hold examination sequences with fat suppression in Dixon technique (VIBE-Dixon) for cardiac thrombus detection. METHOD: From our clinical database, we retrospectively identified consecutive patients between 2014 and 2022 who had definite diagnosis or exclusion of cardiac thrombus confirmed by an independent adjudication committee, serving as the reference standard. All patients received 2D-Cine plus 2D-Late-Gadolinium-Enhancement (Cine + LGE) and VIBE-Dixon sequences. Two blinded readers assessed all images for the presence of cardiac thrombus. The diagnostic accuracy of Cine + LGE and VIBE-Dixon was determined and compared. RESULTS: Among 141 MRI studies (116 male, mean age: 61 years) mean image examination time was 28.8 ± 3.1 s for VIBE-Dixon and 23.3 ± 2.5 min for Cine + LGE. Cardiac thrombus was present in 49 patients (prevalence: 35 %). For both readers sensitivity for thrombus detection was significantly higher in VIBE-Dixon compared with Cine + LGE (Reader 1: 96 % vs.73 %, Reader 2: 96 % vs. 78 %, p < 0.01 for both readers), whereas specificity did not differ significantly (Reader 1: 96 % vs. 98 %, Reader 2: 92 % vs. 93 %, p > 0.1). Overall diagnostic accuracy of VIBE-Dixon was higher than for Cine + LGE (95 % vs. 89 %, p = 0.02) and was non-inferior to the reference standard (Delta ≤ 5 % with probability > 95 %). CONCLUSIONS: Biplanar VIBE-Dixon sequences, acquired within a few seconds, provided a very high diagnostic accuracy for cardiac thrombus detection. They could be used as stand-alone sequences to rapidly screen for cardiac thrombus in patients not amenable to lengthy acquisition times.


Subject(s)
Contrast Media , Thrombosis , Humans , Male , Middle Aged , Gadolinium , Retrospective Studies , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Thrombosis/diagnostic imaging , Image Enhancement/methods
17.
Eur Radiol ; 34(7): 4273-4283, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38177617

ABSTRACT

OBJECTIVES: To determine the diagnostic accuracy of ultra-high-resolution photon-counting detector CT angiography (UHR PCD-CTA) for evaluating coronary stent patency compared to invasive coronary angiography (ICA). METHODS: Consecutive, clinically referred patients with prior coronary stent implantation were prospectively enrolled between August 2022 and March 2023 and underwent UHR PCD-CTA (collimation, 120 × 0.2 mm). Two radiologists independently analyzed image quality of the in-stent lumen using a 5-point Likert scale, ranging from 1 ("excellent") to 5 ("non-diagnostic"), and assessed all coronary stents for the presence of in-stent stenosis (≥ 50% lumen narrowing). The diagnostic accuracy of UHR PCD-CTA was determined, with ICA serving as the standard of reference. RESULTS: A total of 44 coronary stents in 18 participants (mean age, 83 years ± 6 [standard deviation]; 12 women) were included in the analysis. In 3/44 stents, both readers described image quality as non-diagnostic, whereas reader 2 noted a fourth stent to have non-diagnostic image quality. In comparison to ICA, UHR PCD-CTA demonstrated a sensitivity, specificity, and accuracy of 100% (95% CI [confidence interval] 47.8, 100), 92.3% (95% CI 79.1, 98.4), and 93.2% (95% CI 81.3, 98.6) for reader 1 and 100% (95% CI 47.8, 100), 87.2% (95% CI 72.6, 95.7), and 88.6% (95% CI 75.4, 96.2) for reader 2, respectively. Both readers observed a 100% negative predictive value (36/36 stents and 34/34 stents). Stent patency inter-reader agreement was 90.1%, corresponding to a substantial Cohen's kappa value of 0.72. CONCLUSIONS: UHR PCD-CTA enables non-invasive assessment of coronary stent patency with high image quality and diagnostic accuracy. CLINICAL RELEVANCE STATEMENT: Ultra-high-resolution photon-counting detector CT angiography represents a reliable and non-invasive method for assessing coronary stent patency. Its high negative predictive value makes it a promising alternative over invasive coronary angiography for the rule-out of in-stent stenosis. KEY POINTS: • CT-based evaluation of coronary stent patency is limited by stent-induced artifacts and spatial resolution. • Ultra-high-resolution photon-counting detector CT accurately evaluates coronary stent patency compared to invasive coronary angiography. • Photon-counting detector CT represents a promising method for the non-invasive rule-out of in-stent stenosis.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Sensitivity and Specificity , Stents , Humans , Female , Male , Coronary Angiography/methods , Aged, 80 and over , Prospective Studies , Computed Tomography Angiography/methods , Aged , Photons
18.
Eur Heart J Cardiovasc Imaging ; 25(6): 867-877, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38269622

ABSTRACT

AIMS: To identify radiographic differences between patients with uncomplicated and complicated descending aortic dissections. METHODS AND RESULTS: Between April 2009 and July 2021, 209 patients with acute descending aortic dissections were analysed as complicated (malperfusion, rupture, diameter progress, and diameter ≥ 55 mm) or uncomplicated. Detailed CTA measurements (slice thickness ≤ 3 mm) were taken in multiplanar reconstruction. A composite endpoint (early aortic failure) was defined as reoperation, diameter progression, and early mortality. Seventy-seven patients were female (36.8%) [complicated n = 27 (36.5%); uncomplicated n = 50 (37.0%) P = 1.00]. Seventy-four (35%) patients were categorized as morphologically complicated, and 135 (65%) as uncomplicated. In patients with complicated dissections, the dissection extended more frequently to the aortic bifurcation (P = 0.044), the coeliac trunk (P = 0.003), the superior mesenteric artery (P = 0.007), and both iliac arteries (P < 0.001) originated less frequently from the true lumen. The length of the most proximal communication (entry) in type B aortic dissection was longer, 14.0 mm [12.0 mm; 27.0 mm] vs. 6.0 mm [4,0 mm; 13.0 mm] in complicated cases (P = 0.005). Identified risk factors for adverse aortic events were connective tissue disease [HR 8.0 (1.9-33.7 95% CI HR)], length of the aortic arch [HR 4.7 (1.5-15.1 95% CI HR)], a false lumen diameter > 19.38 mm [HR 3.389 (1.1-10.2 95% CI HR)], and origin of the inferior mesenteric artery from the false lumen [HR 4.2 (1.0-5.5 95% CI HR)]. CONCLUSION: We identified significant morphological differences and predictors for adverse events in patients presenting complicated and uncomplicated descending dissections. Our morphological findings will help guide future aortic therapies, taking a tailored patient approach.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Computed Tomography Angiography , Humans , Female , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Male , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/surgery , Computed Tomography Angiography/methods , Middle Aged , Aged , Risk Factors , Retrospective Studies , Aorta, Thoracic/diagnostic imaging , Risk Assessment
19.
Clin Exp Med ; 24(1): 21, 2024 Jan 27.
Article in English | MEDLINE | ID: mdl-38280024

ABSTRACT

This study aimed to analyze the effect of COVID-19 vaccination on the occurrence of ARDS in hospitalized COVID-19 patients. The study population of this retrospective, single-center cohort study consisted of hospitalized COVID-19 patients with known vaccination status and chest computed tomography imaging between July 2021 and February 2022. The impact of vaccination on ARDS in COVID-19 patients was assessed through logistic regression adjusting for demographic differences and confounding factors with statistical differences determined using confidence intervals and effect sizes. A total of 167 patients (69% male, average age 58 years, 95% CI [55; 60], 42% fully vaccinated) were included in the data analysis. Vaccinated COVID-19 patients had a reduced relative risk (RR) of developing ARDS (RR: 0.40, 95% CI [0.21; 0.62]). Consequently, non-vaccinated hospitalized patients had a 2.5-fold higher probability of developing ARDS. This risk reduction persisted after adjusting for several confounding variables (RR: 0.64, 95% CI [0.29; 0.94]) in multivariate analysis. The protective effect of COVID-19 vaccination increased with ARDS severity (RR: 0.61, 95% CI [0.37; 0.92]). Particularly, patients under 60 years old were at risk for ARDS onset and seemed to benefit from COVID-19 vaccination (RR: 0.51, 95% CI [0.20; 0.90]). COVID-19 vaccination showed to reduce the risk of ARDS occurrence in hospitalized COVID-19 patients, with a particularly strong effect in patients under 60 years old and those with more severe ARDS.


Subject(s)
COVID-19 , Respiratory Distress Syndrome , Humans , Male , Middle Aged , Female , COVID-19/prevention & control , Cohort Studies , Retrospective Studies , COVID-19 Vaccines , Respiratory Distress Syndrome/prevention & control , Respiratory Distress Syndrome/epidemiology , Vaccination
20.
PLOS Digit Health ; 3(1): e0000429, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38227569

ABSTRACT

AIM: Diabetes is a global health challenge, and many individuals are undiagnosed and not aware of their increased risk of morbidity/mortality although dedicated tests are available, which indicates the need for novel population-wide screening approaches. Here, we developed a deep learning pipeline for opportunistic screening of impaired glucose metabolism using routine magnetic resonance imaging (MRI) of the liver and tested its prognostic value in a general population setting. METHODS: In this retrospective study a fully automatic deep learning pipeline was developed to quantify liver shape features on routine MR imaging using data from a prospective population study. Subsequently, the association between liver shape features and impaired glucose metabolism was investigated in individuals with prediabetes, type 2 diabetes and healthy controls without prior cardiovascular diseases. K-medoids clustering (3 clusters) with a dissimilarity matrix based on Euclidean distance and ordinal regression was used to assess the association between liver shape features and glycaemic status. RESULTS: The deep learning pipeline showed a high performance for liver shape analysis with a mean Dice score of 97.0±0.01. Out of 339 included individuals (mean age 56.3±9.1 years; males 58.1%), 79 (23.3%) and 46 (13.6%) were classified as having prediabetes and type 2 diabetes, respectively. Individuals in the high risk cluster using all liver shape features (n = 14) had a 2.4 fold increased risk of impaired glucose metabolism after adjustment for cardiometabolic risk factors (age, sex, BMI, total cholesterol, alcohol consumption, hypertension, smoking and hepatic steatosis; OR 2.44 [95% CI 1.12-5.38]; p = 0.03). Based on individual shape features, the strongest association was found between liver volume and impaired glucose metabolism after adjustment for the same risk factors (OR 1.97 [1.38-2.85]; p<0.001). CONCLUSIONS: Deep learning can estimate impaired glucose metabolism on routine liver MRI independent of cardiometabolic risk factors and hepatic steatosis.

SELECTION OF CITATIONS
SEARCH DETAIL