Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 275
Filter
2.
Circ Genom Precis Med ; 17(3): e004320, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38804128

ABSTRACT

BACKGROUND: Substantial data support a heritable basis for supraventricular tachycardias, but the genetic determinants and molecular mechanisms of these arrhythmias are poorly understood. We sought to identify genetic loci associated with atrioventricular nodal reentrant tachycardia (AVNRT) and atrioventricular accessory pathways or atrioventricular reciprocating tachycardia (AVAPs/AVRT). METHODS: We performed multiancestry meta-analyses of genome-wide association studies to identify genetic loci for AVNRT (4 studies) and AVAP/AVRT (7 studies). We assessed evidence supporting the potential causal effects of candidate genes by analyzing relations between associated variants and cardiac gene expression, performing transcriptome-wide analyses, and examining prior genome-wide association studies. RESULTS: Analyses comprised 2384 AVNRT cases and 106 489 referents, and 2811 AVAP/AVRT cases and 1,483 093 referents. We identified 2 significant loci for AVNRT, which implicate NKX2-5 and TTN as disease susceptibility genes. A transcriptome-wide association analysis supported an association between reduced predicted cardiac expression of NKX2-5 and AVNRT. We identified 3 significant loci for AVAP/AVRT, which implicate SCN5A, SCN10A, and TTN/CCDC141. Variant associations at several loci have been previously reported for cardiac phenotypes, including atrial fibrillation, stroke, Brugada syndrome, and electrocardiographic intervals. CONCLUSIONS: Our findings highlight gene regions associated with ion channel function (AVAP/AVRT), as well as cardiac development and the sarcomere (AVAP/AVRT and AVNRT) as important potential effectors of supraventricular tachycardia susceptibility.


Subject(s)
Genome-Wide Association Study , Tachycardia, Supraventricular , Humans , Tachycardia, Supraventricular/genetics , Genetic Predisposition to Disease , Tachycardia, Atrioventricular Nodal Reentry/genetics , Polymorphism, Single Nucleotide , Connectin/genetics , Transcriptome
3.
Circ Arrhythm Electrophysiol ; 17(5): e012667, 2024 May.
Article in English | MEDLINE | ID: mdl-38655693

ABSTRACT

BACKGROUND: We previously presented the safety and early efficacy of the inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed-field Ablation [PFA] System With Irreversible Electroporation [IRE]). With the study's conclusion, we report the outcomes of the full pivotal study cohort, with an additional analysis of predictors of success. METHODS: InspIRE was a prospective, multicenter, single-arm clinical trial of drug-refractory paroxysmal atrial fibrillation. Pulmonary vein isolation was performed with a variable-loop circular catheter integrated with a 3-dimensional mapping system. Follow-up with 24-hour Holter was at 3, 6, and 12 months, as well as remote rhythm monitoring: weekly from 3 to 5 months, monthly from 6 to 12 months, and for symptoms. The primary effectiveness end point (PEE) was acute pulmonary vein isolation plus freedom from any atrial arrhythmia at 12 months. Additional subanalyses report predictors of PEE success. RESULTS: The patient cohort included 186 patients: aged 59±10 years, female 30%, and CHA2DS2-VASc 1.3±1.2. The previously reported primary adverse event rate was 0%. One serious procedure-related adverse event, urinary retention, was reported. The PEE was achieved in 75.6% (95% CI, 69.5%-81.8%). The clinical success of freedom from symptomatic recurrence was 81.7% (95% CI, 76.1%-87.2%). Simulating a monitoring method used in standard real-world practice (without protocol-driven remote rhythm monitoring), this translates to a freedom from all and symptomatic recurrence of 85.8% (95% CI, 80.8%-90.9%) or 94.0% (95% CI, 90.6%-97.5%), respectively. Multivariate analyses revealed that left ventricular ejection fraction ≥60% (adjusted odds ratio, 0.30) and patients receiving ≥48 PFA applications (adjusted odds ratio, 0.28) were independent predictors of PEE success. Moreover, PEE success was 79.2% in patients who received ≥12 PFA applications per vein compared with 57.1% in patients receiving fewer PFA applications. CONCLUSIONS: The inspIRE study confirms the safety and effectiveness of pulmonary vein isolation using the novel 3-dimensional mapping integrated circular loop catheter. An optimal number of PFA applications (≥48 total or ≥12 per vein) resulted in an improved 1-year success rate of ≈80%. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04524364.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Female , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Male , Middle Aged , Catheter Ablation/instrumentation , Catheter Ablation/methods , Catheter Ablation/adverse effects , Prospective Studies , Aged , Time Factors , Heart Rate , Action Potentials , Electrocardiography, Ambulatory/instrumentation , Recurrence , Cardiac Catheters , Predictive Value of Tests , Treatment Outcome , Imaging, Three-Dimensional , Risk Factors , Equipment Design , Electrophysiologic Techniques, Cardiac
7.
Pacing Clin Electrophysiol ; 46(12): 1447-1454, 2023 12.
Article in English | MEDLINE | ID: mdl-37997450

ABSTRACT

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are routinely implanted using intravenous drugs for sedation. However, some patients are poor candidates for intravenous sedation. OBJECTIVE: We present a case series demonstrating the safety and efficacy of a novel, ultrasound-guided nerve block technique that allows for pre-pectoral CIED implantation. The targets are the supraclavicular nerve (SCN) and pectoral nerve (PECS1). METHODS: We enrolled 20 patients who were planned for new CIED implantation. Following US-localization of the SCN and PECS1, local anesthetic (LA) was instilled at least 30-60 min pre-procedure. Successful nerve block was determined if < 5 mL of intraprocedural LA was used, along with lack of sensation with skin and deep tissue pinprick. Optional sedation was offered to patients' pre-procedure if discomfort was reported. RESULTS: Seventeen patients (85%) had a successful periprocedural nerve block, with only three patients exceeding 5 mL of LA. SCN and PECS1 success occurred in 19 (95%) and 18 (90%) patients, respectively. The overall success of nerve block by fulfilling all the criteria was demonstrated in 17 out of 20 patients (85%). Patients who reported no pain (VAS score = 0) were distributed as follows: 13 patients (65%) in the immediate post-procedure interval, 18 patients (90%) at the 1 h post-implant interval, and 14 patients (70%) at the 24 h post- implant interval. The median cumulative VAS score was 0 (IQR = 0 - 1). There were no reported significant adverse effects. CONCLUSION: SCN and PECS1 nerve blocks are safe and effective for patients undergoing CIED implantation to minimize or eliminate the use of intravenous sedation.


Subject(s)
Analgesia , Nerve Block , Humans , Pilot Projects , Nerve Block/methods , Pain Management , Anesthetics, Local/therapeutic use
10.
Circ Arrhythm Electrophysiol ; 16(3): e011780, 2023 03.
Article in English | MEDLINE | ID: mdl-36735937

ABSTRACT

BACKGROUND: The inspIRE study (Study for Treatment of Paroxysmal Atrial Fibrillation [PAF] by Pulsed Field Ablation [PFA] System With Irreversible Electroporation [IRE]) evaluated safety and effectiveness of a fully integrated biphasic pulsed field ablation (PFA) system with a variable-loop circular catheter for the treatment of drug-refractory paroxysmal atrial fibrillation. METHODS: Subjects underwent pulmonary vein (PV) isolation with the PFA system, using at least 12 applications per vein; adenosine/isoproterenol was administered to confirm entrance block. Wave I assessed initial safety, including for esophageal lesions, silent cerebral lesions, and PV stenosis. Wave II (pivotal phase) tested (1) primary safety, incidence of early-onset primary adverse events, and (2) primary effectiveness, confirmed PV isolation with freedom from documented atrial arrhythmia at 12 months. The study design specified an interim analysis to determine early success once 30 subjects reached the 12-month follow-up and all subjects reached 3-month follow-up. RESULTS: Across 13 centers in Europe/Canada, 226 subjects were enrolled, met criteria for safety and effectiveness evaluations, and received PFA (Wave I, 40; Wave II, 186). Wave I demonstrated no esophageal thermal lesions or PV stenosis. Among 39 subjects with cerebral magnetic resonance imaging, silent cerebral lesions were detected in 4 of the first 6 subjects, after which workflow enhancements, including a 10-second pause between PFA applications, were implemented; subsequently, only 4 of 33 subjects had silent cerebral lesions. In the Wave II phase, no primary adverse events were reported. Upon declaring early success, 83 subjects reached 12-month follow-up. With 100% entrance block, PV isolation without acute reconnection was achieved in 97.1% of targeted veins. For Wave II, the primary effectiveness end point per Kaplan-Meier at the time of interim analysis was 70.9%; 12-month freedom from symptomatic atrial fibrillation/atrial flutter/atrial tachycardia recurrence and repeat ablation was 78.9% and 92.3%, respectively. Total procedure and transpired PFA times were 70.1±27.7 and 26.7±14.0 minutes, respectively. CONCLUSIONS: The inspIRE trial confirmed the safety and effectiveness of the novel mapping-integrated PFA system. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; unique identifier: NCT04524364.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Constriction, Pathologic/etiology , Constriction, Pathologic/surgery , Treatment Outcome , Catheters , Europe , Pulmonary Veins/surgery , Stenosis, Pulmonary Vein/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
11.
N Engl J Med ; 388(2): 105-116, 2023 01 12.
Article in English | MEDLINE | ID: mdl-36342178

ABSTRACT

BACKGROUND: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Subject(s)
Anti-Arrhythmia Agents , Atrial Fibrillation , Catheter Ablation , Cryosurgery , Humans , Anti-Arrhythmia Agents/adverse effects , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/drug therapy , Atrial Fibrillation/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cryosurgery/adverse effects , Cryosurgery/methods , Recurrence , Tachycardia/etiology , Treatment Outcome , Disease Progression , Follow-Up Studies
12.
Am Heart J ; 254: 133-140, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36030965

ABSTRACT

BACKGROUND: Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE: The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN: A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION: Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Prospective Studies , Quality of Life , Pulmonary Veins/surgery , Catheter Ablation/methods , Treatment Outcome , Recurrence
13.
PLoS One ; 17(7): e0269592, 2022.
Article in English | MEDLINE | ID: mdl-35802680

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) is associated with extracellular matrix (ECM) remodelling and often coexists with myocardial fibrosis (MF); however, the causality of these conditions is not well established. OBJECTIVE: We aim to corroborate AF to MF causality by quantifying left atrial (LA) fibrosis in cardiac magnetic resonance (CMR) images after persistent rapid ventricular pacing and subsequent AF using a canine model and histopathological validation. METHODS: Twelve canines (9 experimental, 3 control) underwent baseline 3D LGE-CMR imaging at 3T followed by insertion of a pacing device and 5 weeks of rapid ventricular pacing to induce AF (experimental) or no pacing (control). Following the 5 weeks, pacing devices were removed to permit CMR imaging followed by excision of the hearts and histopathological imaging. LA myocardial segmentation was performed manually at baseline and post-pacing to permit volumetric %MF quantification using the image intensity ratio (IIR) technique, wherein fibrosis was defined as pixels > mean LA myocardium intensity + 2SD. RESULTS: Volumetric %MF increased by an average of 2.11 ± 0.88% post-pacing in 7 of 9 experimental dogs. While there was a significant difference between paired %MF measurements from baseline to post-pacing in experimental dogs (P = 0.019), there was no significant change in control dogs (P = 0.019 and P = 0.5, Wilcoxon signed rank tests). The median %MF for paced animals was significantly greater than that of non-paced dogs at the 5-week post-insertion time point (P = 0.009, Mann Whitney U test). Histopathological imaging yielded an average %MF of 19.42 ± 4.80% (mean ± SD) for paced dogs compared to 1.85% in one control dog. CONCLUSION: Persistent rapid ventricular pacing and subsequent AF leads to an increase in LA fibrosis volumes measured by the IIR technique; however, quantification is limited by inherent image acquisition parameters and observer variability.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Animals , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/pathology , Atrial Fibrillation/therapy , Cardiomyopathies/pathology , Contrast Media , Dogs , Fibrosis , Gadolinium , Heart Atria , Magnetic Resonance Imaging/methods
14.
Curr Cardiol Rep ; 24(10): 1227-1231, 2022 10.
Article in English | MEDLINE | ID: mdl-35870075

ABSTRACT

PURPOSE OF REVIEW: Heart failure (HF) and atrial fibrillation (AF) frequently co-exist, with the prevalence of AF increasing in patients with more advanced HF symptoms. When present, AF increases morbidity and mortality in patients with HF. The purpose of this review is to examine emerging evidence addressing the value of restoration and maintenance of sinus rhythm in patients with HF. RECENT FINDINGS: Earlier trials comparing a rhythm control strategy with antiarrhythmic drugs have failed to demonstrate benefit in patients with HF and reduced ejection fraction. More recent trials, including the recently published RAFT-AF, utilizing catheter ablation for rhythm control, have shown greater promise, possibly due to reduced medication-related side effects and higher efficacy in maintaining sinus rhythm. A strategy of sinus rhythm maintenance with catheter ablation appears to improve mortality, reduce HF events and improve quality of life in patients with AF and HF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Anti-Arrhythmia Agents/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Humans , Quality of Life , Treatment Outcome
15.
J Interv Card Electrophysiol ; 65(2): 481-489, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35739438

ABSTRACT

BACKGROUND: Transseptal puncture to achieve left atrial access is necessary for many cardiac procedures, including atrial fibrillation ablation. More recently, there has been an increasing need for left atrial access using large caliber sheaths, which increases risk of perforation associated with the initial advancement into the left atrium. We compared the effectiveness of a radiofrequency needle-based transseptal system versus conventional needle for transseptal access. METHODS: This prospective controlled trial randomized 161 patients with symptomatic paroxysmal atrial fibrillation undergoing cryoballoon pulmonary vein isolation to transseptal access with a commercially available transseptal system (radiofrequency needle plus stiff pigtail wire; RF + Pigtail group) versus conventional transseptal access (standard group). The primary outcome was time required for left atrial access. Secondary outcomes included failure of the assigned transseptal system, radiation exposure, and complications. RESULTS: The median transseptal puncture time was significantly shorter using the radiofrequency needle plus stiff pigtail wire transseptal system compared with conventional transseptal (840 ± 323 vs. 956 ± 407 s, P = 0.0489). Compared to conventional transseptal puncture, fewer transseptal attempts were required (1.0 ± 0.5 RF applications vs. 1.3 ± 0.8 mechanical punctures, P = 0.0123) and the fluoroscopy time was significantly shorter (72.0 [IQR 48.0, 129.0] vs. 93.0 [IQR 60.0, 171.0] s, P = 0.0490) with the radiofrequency needle plus stiff pigtail wire transseptal system. Failure to achieve transseptal LA access with the assigned system was rarely observed (1.3% vs. 5.7%, P = 0.2192). There were no procedural complications observed with either system. CONCLUSIONS: The use of a radiofrequency needle plus stiff pigtail wire resulted in shorter time to left atrial access and reduced fluoroscopy time compared to left atrial access using conventional transseptal equipment. TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT03199703.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Catheter Ablation/methods , Prospective Studies , Punctures , Treatment Outcome
16.
Circulation ; 145(23): 1693-1704, 2022 06 07.
Article in English | MEDLINE | ID: mdl-35313733

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) frequently coexist and can be challenging to treat. Pharmacologically based rhythm control of AF has not proven to be superior to rate control. Ablation-based rhythm control was compared with rate control to evaluate if clinical outcomes in patients with HF and AF could be improved. METHODS: This was a multicenter, open-label trial with blinded outcome evaluation using a central adjudication committee. Patients with high-burden paroxysmal (>4 episodes in 6 months) or persistent (duration <3 years) AF, New York Heart Association class II to III HF, and elevated NT-proBNP (N-terminal pro brain natriuretic peptide) were randomly assigned to ablation-based rhythm control or rate control. The primary outcome was a composite of all-cause mortality and all HF events, with a minimum follow-up of 2 years. Secondary outcomes included left ventricular ejection fraction, 6-minute walk test, and NT-proBNP. Quality of life was measured using the Minnesota Living With Heart Failure Questionnaire and the AF Effect on Quality of Life. The primary analysis was time-to-event using Cox proportional hazards modeling. The trial was stopped early because of a determination of apparent futility by the Data Safety Monitoring Committee. RESULTS: From December 1, 2011, to January 20, 2018, 411 patients were randomly assigned to ablation-based rhythm control (n=214) or rate control (n=197). The primary outcome occurred in 50 (23.4%) patients in the ablation-based rhythm-control group and 64 (32.5%) patients in the rate-control group (hazard ratio, 0.71 [95% CI, 0.49-1.03]; P=0.066). Left ventricular ejection fraction increased in the ablation-based group (10.1±1.2% versus 3.8±1.2%, P=0.017), 6-minute walk distance improved (44.9±9.1 m versus 27.5±9.7 m, P=0.025), and NT-proBNP demonstrated a decrease (mean change -77.1% versus -39.2%, P<0.0001). Minnesota Living With Heart Failure Questionnaire demonstrated greater improvement in the ablation-based rhythm-control group (least-squares mean difference of -5.4 [95% CI, -10.5 to -0.3]; P=0.0036), as did the AF Effect on Quality of Life score (least-squares mean difference of 6.2 [95% CI, 1.7-10.7]; P=0.0005). Serious adverse events were observed in 50% of patients in both treatment groups. CONCLUSIONS: In patients with high-burden AF and HF, there was no statistical difference in all-cause mortality or HF events with ablation-based rhythm control versus rate control; however, there was a nonsignificant trend for improved outcomes with ablation-based rhythm control over rate control. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01420393.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/surgery , Humans , Quality of Life , Stroke Volume , Treatment Outcome , Ventricular Function, Left
17.
Can J Cardiol ; 38(8): 1271-1276, 2022 08.
Article in English | MEDLINE | ID: mdl-35346798

ABSTRACT

BACKGROUND: Patients with hemodynamically tolerated ventricular tachycardia (VT) and minimally reduced left ventricular ejection fraction (LVEF) remain a group that presents a prognostic and therapeutic dilemma. METHODS: We studied patients from our implanted cardioverter-defibrillator (ICD) database who received ICDs for hemodynamically tolerated VT and mildly reduced LVEF (36%-49%) at time of implant between May 2015 and December 2019. Time to appropriate ICD therapy was assessed. Clinical features associated with recurrent VT/ventricular fibrillation (VF) with ICD therapies were explored using binary logistic regression. RESULTS: Among 2037 ICDs placed between May 2015 and December 2019, 64 subjects met the inclusion criteria. The mean age of the study group was 68 ± 12 years, and 58 (90.6%) subjects were male. Average ejection fraction was 40% ± 4.4 (range 36%-49%). Twenty-two (34%) subjects received antitachycardia pacing (ATP) for VT at 229 ± 265 days after ICD placement. Fifteen (23%) subjects received appropriate ICD shocks 305 ± 321 days after implant. The rate of recurrent VT/VF among the 37 patients with ICD therapy was 195 ± 39 beats per minute (bpm). This was significantly more rapid than initial presenting VT rates before ICD placement (183 ± 27 bpm) (P = 0.048). Multivariate analysis showed no factors independently associated with recurrent VT/VF. CONCLUSIONS: Patients with mildly impaired LV function and hemodynamically tolerated VT receive appropriate ICD therapies over the 3 years following implant. This patient group warrants further investigation, as their recurrent VT/VF rates can be much more rapid, and 23% go on to receive appropriate ICD shocks.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Aged , Aged, 80 and over , Arrhythmias, Cardiac , Electric Countershock , Female , Humans , Male , Middle Aged , Stroke Volume , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/therapy , Ventricular Function, Left
20.
Circulation ; 144(24): 1899-1911, 2021 12 14.
Article in English | MEDLINE | ID: mdl-34587750

ABSTRACT

BACKGROUND: The most prominent risk factor for atrial fibrillation (AF) is chronological age; however, underlying mechanisms are unexplained. Algorithms using epigenetic modifications to the human genome effectively predict chronological age. Chronological and epigenetic predicted ages may diverge in a phenomenon referred to as epigenetic age acceleration (EAA), which may reflect accelerated biological aging. We sought to evaluate for associations between epigenetic age measures and incident AF. METHODS: Measures for 4 epigenetic clocks (Horvath, Hannum, DNA methylation [DNAm] PhenoAge, and DNAm GrimAge) and an epigenetic predictor of PAI-1 (plasminogen activator inhibitor-1) levels (ie, DNAm PAI-1) were determined for study participants from 3 population-based cohort studies. Cox models evaluated for associations with incident AF and results were combined via random-effects meta-analyses. Two-sample summary-level Mendelian randomization analyses evaluated for associations between genetic instruments of the EAA measures and AF. RESULTS: Among 5600 participants (mean age, 65.5 years; female, 60.1%; Black, 50.7%), there were 905 incident AF cases during a mean follow-up of 12.9 years. Unadjusted analyses revealed all 4 epigenetic clocks and the DNAm PAI-1 predictor were associated with statistically significant higher hazards of incident AF, though the magnitudes of their point estimates were smaller relative to the associations observed for chronological age. The pooled EAA estimates for each epigenetic measure, with the exception of Horvath EAA, were associated with incident AF in models adjusted for chronological age, race, sex, and smoking variables. After multivariable adjustment for additional known AF risk factors that could also potentially function as mediators, pooled EAA measures for 2 clocks remained statistically significant. Five-year increases in EAA measures for DNAm GrimAge and DNAm PhenoAge were associated with 19% (adjusted hazard ratio [HR], 1.19 [95% CI, 1.09-1.31]; P<0.01) and 15% (adjusted HR, 1.15 [95% CI, 1.05-1.25]; P<0.01) higher hazards of incident AF, respectively. Mendelian randomization analyses for the 5 EAA measures did not reveal statistically significant associations with AF. CONCLUSIONS: Our study identified adjusted associations between EAA measures and incident AF, suggesting that biological aging plays an important role independent of chronological age, though a potential underlying causal relationship remains unclear. These aging processes may be modifiable and not constrained by the immutable factor of time.


Subject(s)
Aging , DNA Methylation , Epigenesis, Genetic , Models, Cardiovascular , Models, Genetic , Aged , Aging/genetics , Aging/metabolism , Atrial Fibrillation/epidemiology , Atrial Fibrillation/genetics , Atrial Fibrillation/metabolism , Epigenomics , Female , Follow-Up Studies , Humans , Incidence , Male , Mendelian Randomization Analysis , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...