Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 248
1.
BMC Pregnancy Childbirth ; 24(1): 195, 2024 Mar 12.
Article En | MEDLINE | ID: mdl-38475706

Bladder exstrophy (BE) is a congenital genito-urinary malformation where there is a defect in the abdominal wall resulting in a protruding open bladder with exposed mucosa (Resnik R.P. et al. Creasy and Resnik's maternal-fetal medicine: principles and practice. Elsevier, 2019). Several reconstructive procedures are required to correct the anomalies, resulting in an ileal conduit which is an alternate urinary reservoir reconstructed from the terminal ileum (Madersbacher S, et al. J Urol 169(3):985-90, 2003). We describe the care of a pregnant woman with BE and outline the principles of management of her pregnancy with a multidisciplinary team. Timely pre-operative planning is advised to minimise intraoperative complications in the event of a caesarean section. The woman went on to have an uncomplicated classical caesarean section at term by midline laparotomy with a good outcome for both mother and baby.


Bladder Exstrophy , Plastic Surgery Procedures , Pregnancy Complications , Humans , Pregnancy , Female , Cesarean Section/adverse effects , Bladder Exstrophy/complications , Bladder Exstrophy/surgery , Pregnancy Complications/etiology , Urinary Bladder
3.
Phys Med Biol ; 68(19)2023 09 20.
Article En | MEDLINE | ID: mdl-37659394

Aim. Flat panel detectors with small pixel sizes general can potentially improve imaging performance in radiography applications requiring fine detail resolution. This study evaluated the imaging performance of seven detectors, covering a wide range of pixel sizes, in the frame of orthopaedic applications.Material and methods. Pixel sizes ranged from 175 (detector A175) to 76µm (detector G76). Modulation transfer function (MTF) and detective quantum efficiency (DQE) were measured using International Electrotechnical Commission (IEC) RQA3 beam quality. Threshold contrast (CT) and a detectability index (d') were measured at three air kerma/image levels. Rabbit shoulder images acquired at 60 kV, over five air kerma levels, were evaluated in a visual grading study for anatomical sharpness, image noise and overall diagnostic image quality by four radiologists. The detectors were compared to detector E124.Results. The 10% point of the MTF ranged from 3.21 to 4.80 mm-1, in going from detector A175to detector G76. DQE(0.5 mm-1) measured at 2.38µGy/image was 0.50 ± 0.05 for six detectors, but was higher for F100at 0.62. High frequency DQE was superior for the smaller pixel detectors, howeverCTfor 0.25 mm discs correlated best with DQE(0.5 mm-1). Correlation betweenCTand the detectability model was good (R2= 0.964).CTfor 0.25 mm diameter discs was significantly higher for D150and F100compared to E124. The visual grading data revealed higher image quality ratings for detectors D125and F100compared to E124. An increase in air kerma was associated with improved perceived sharpness and overall quality score, independent of detector. Detectors B150, D125, F100and G76, performed well in specific tests, however only F100consistently outperformed the reference detector.Conclusion. Pixel size alone was not a reliable predictor of small detail detectability or even perceived sharpness in a visual grading analysis study.


Orthopedics , Animals , Rabbits , X-Rays , Radiography , Azo Compounds
4.
Ultrasound Obstet Gynecol ; 62(4): 497-503, 2023 10.
Article En | MEDLINE | ID: mdl-37247395

OBJECTIVE: To evaluate the impact of detailed late first-trimester ultrasound (LFTU) on the positive predictive value (PPV) of a high-risk non-invasive prenatal test (NIPT) result for various chromosomal abnormalities. METHODS: This was a retrospective study of all cases undergoing invasive prenatal testing from three tertiary providers of obstetric ultrasound over 4 years, each using NIPT as a first-line screening test. Data were collected from pre-NIPT ultrasound, NIPT, LFTU, placental serology and later ultrasound examinations. Prenatal testing for chromosomal abnormalities was performed by microarray, initially using array comparative genomic hybridization and then single nucleotide polymorphism (SNP) array for the last 2 years. Uniparental disomy testing was performed by SNP array during all 4 years. The majority of NIPT tests were analyzed using the Illumina platform, initially confined to the assessment of the common autosomal trisomies, sex chromosome aneuploidies and rare autosomal trisomies (RAT), then extending to genome-wide analysis for the last 2 years. RESULTS: Amniocentesis or chorionic villus sampling (CVS) was performed on 2657 patients, 1352 (51%) of whom had undergone prior NIPT, with 612 (45%) of these returning a high-risk result and meeting the inclusion criteria for the study. LFTU findings significantly affected the PPV of the NIPT result for trisomies 13 (T13), 18 (T18) and 21 (T21), monosomy X (MX) and RAT but not for the other sex chromosomal abnormalities or segmental imbalances (> 7 Mb). Abnormal LFTU increased the PPV close to 100% for T13, T18, T21, MX and RAT. The magnitude of the change in PPV was highest for the most severe chromosomal abnormalities. When LFTU was normal, the incidence of confined placental mosaicism (CPM) was highest in those with a high-risk NIPT result for T13, followed by T18 and T21. After normal LFTU, the PPV for T21, T18, T13 and MX decreased to 68%, 57%, 5% and 25%, respectively. CONCLUSIONS: LFTU after a high-risk NIPT result can alter the PPV for many chromosomal abnormalities, assisting counseling regarding invasive prenatal testing and pregnancy management. The high PPVs of NIPT for T21 and T18 are not sufficiently modified by normal LFTU findings to alter management. These at-risk patients should be offered CVS for earlier diagnosis, particularly given the low rate of CPM associated with these aneuploidies. Patients with a high-risk NIPT result for T13 and normal LFTU findings often wait for amniocentesis or avoid invasive testing altogether given the low PPV and higher rate of CPM in this context. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Placenta , Trisomy , Pregnancy , Humans , Female , Pregnancy Trimester, First , Retrospective Studies , Comparative Genomic Hybridization , Prenatal Diagnosis , Aneuploidy , Sex Chromosome Aberrations , Trisomy 13 Syndrome/diagnosis
6.
Ocul Immunol Inflamm ; 31(4): 710-716, 2023 May.
Article En | MEDLINE | ID: mdl-35404742

PURPOSE: To report uveitis' spectrum in a private practice cohort in the city of Buenos Aires, Argentina. METHODS: Retrospective review at Instituto de la Visión (November 2011-October 2015). Standard demographics, ethnicity and Native American aboriginal ancestry were recorded. RESULTS: Among 212 patients, median age 45 (6-97), 10% pediatric, 35% bilateral, 72% non-idiopathic, 36% infectious. Anterior uveitis presented in 50%, followed by posterior (32%), intermediate (9%) and panuveitis (8%). Frequent visits (≥ 6 per year) needed by 29%: posterior, non-idiopathic disease with 79% systemic immunosuppression requirement was their main presentation. Native American aboriginal ancestry was reported by 22.64% of the whole cohort and 37% of frequent visits' subgroup. CONCLUSIONS: Unilateral, non-idiopathic, non-infectious anterior uveitis was the most frequent presentation, in agreement with reports coming from western developed cities. The multi-racial Argentinian population with specific Native American aboriginal ancestry might contribute to certain forms of posterior uveitis and their response to treatment.


Uveitis, Anterior , Uveitis , Humans , Child , Middle Aged , Argentina/epidemiology , Tertiary Healthcare , Uveitis/diagnosis , Uveitis/epidemiology , Tertiary Care Centers , Uveitis, Anterior/epidemiology , Referral and Consultation , Retrospective Studies
7.
Acta Gastroenterol Belg ; 85(3): 537-539, 2022.
Article En | MEDLINE | ID: mdl-36198300

Question: A 62-year old man presented to our tertiary care hospital for a second opinion regarding end stage COPD GOLD 4D. He had a medical history of former alcohol use complicated by liver steatosis and former smoking. Upon admission the patient complained of constipation and abdominal distension. Physical examination showed diffuse hypertympanic percussion and diffuse abdominal pain upon palpation without signs of peritoneal irrita- tion. CRP, hemoglobin, lactate, liver enzymes, and serum creatinine were within limits of normal. Abdominal radiography showed dilatation of the colon transversum with intramural and intra-abdominal free air (Figure 1). Contrast-enhanced abdominal CT showed extensive intramural air in the right hemicolon (Figure 2). Answer: The findings are consistent with pneumatosis intestinalis (PI). Conservative management with oxygen, triple bronchodilator therapy, fasting, laxation and antibiotic therapy resulted in resolution of the clinical symptoms.


Pneumatosis Cystoides Intestinalis , Pulmonary Disease, Chronic Obstructive , Anti-Bacterial Agents/therapeutic use , Bronchodilator Agents , Constipation/etiology , Creatinine , Humans , Lactates , Male , Middle Aged , Oxygen , Pneumatosis Cystoides Intestinalis/complications , Pulmonary Disease, Chronic Obstructive/complications , Pulmonary Disease, Chronic Obstructive/diagnosis
8.
ESC Heart Fail ; 9(6): 4315-4324, 2022 12.
Article En | MEDLINE | ID: mdl-36043434

Multisystem Inflammatory Syndrome in Adult (MIS-A) is a rare COVID-19 complication, presenting as fever with laboratory evidence of inflammation, severe illness requiring hospitalization and multisystem organ involvement. We report on a 25-year-old man presenting with fever, rash, abdominal pain, diarrhoea and vomiting following prior asymptomatic COVID-19 infection. He developed refractory shock and type 1 respiratory insufficiency requiring mechanical ventilation. Diagnostic testing revealed significant inflammation, anemia, thrombocytopenia, acute kidney injury, hepatosplenomegaly, colitis, lymphadenopathy and myocarditis necessitating inotropy. Ventilatory, vasopressor and inotropic support was weaned following pulse corticosteroids and intravenous immunoglobulins. Heart failure therapy was started. Short-term follow-up shows resolution of inflammation and cardiac dysfunction.


COVID-19 , Myocarditis , Male , Humans , Adult , COVID-19/complications , COVID-19/diagnosis , SARS-CoV-2 , Shock, Cardiogenic/diagnosis , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Myocarditis/complications , Myocarditis/diagnosis , Inflammation , Cardiotonic Agents
9.
Int J Retina Vitreous ; 8(1): 33, 2022 Jun 07.
Article En | MEDLINE | ID: mdl-35672810

Tertiary outpatient ophthalmology clinics are high-risk environments for COVID-19 transmission, especially retina clinics, where regular follow-up is needed for elderly patients with multiple comorbidities. Intravitreal injection therapy (IVT) for chronic macular diseases, is one of the most common procedures performed, associated with a significant burden of care because of the vigorous treatment regimen associated with multiple investigations. While minimizing the risk of COVID-19 infection transmission is a priority, this must be balanced against the continued provision of sight-saving ophthalmic care to patients at risk of permanent vision loss. This review aims to give evidence-based guidelines on managing IVT during the COVID-19 pandemic in common macular diseases such as age-related macular degeneration, diabetic macula edema and retinal vascular disease and to report on how the COVID-19 pandemic has affected IVT practices worldwide.To illustrate some real-world examples, 18 participants in the International Retina Collaborative, from 15 countries and across four continents, were surveyed regarding pre- and during- COVID-19 pandemic IVT practices in tertiary ophthalmic centers. The majority of centers reported a reduction in the number of appointments to reduce the risk of the spread of COVID-19 with varying changes to their IVT regimen to treat various macula diseases. Due to the constantly evolving nature of the COVID-19 pandemic, and the uncertainty about the normal resumption of health services, we suggest that new solutions for eye healthcare provision, like telemedicine, may be adopted in the future when we consider new long-term adaptations required to cope with the COVID-19 pandemic.

10.
Radiother Oncol ; 173: 188-196, 2022 08.
Article En | MEDLINE | ID: mdl-35661677

Surface guidance systems enable patient positioning and motion monitoring without using ionising radiation. Surface Guided Radiation Therapy (SGRT) has therefore been widely adopted in radiation therapy in recent years, but guidelines on workflows and specific quality assurance (QA) are lacking. This ESTRO-ACROP guideline aims to give recommendations concerning SGRT roles and responsibilities and highlights common challenges and potential errors. Comprehensive guidelines for procurement, acceptance, commissioning, and QA of SGRT systems installed on computed tomography (CT) simulators, C-arm linacs, closed-bore linacs, and particle therapy treatment systems are presented that will help move to a consensus among SGRT users and facilitate a safe and efficient implementation and clinical application of SGRT.


Radiotherapy, Image-Guided , Humans , Particle Accelerators , Patient Positioning , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Image-Guided/methods , Tomography, X-Ray Computed/methods
11.
Ultrasound Obstet Gynecol ; 59(1): 128-129, 2022 01.
Article En | MEDLINE | ID: mdl-34985816
12.
Ultrasound Obstet Gynecol ; 59(1): 114-119, 2022 Jan.
Article En | MEDLINE | ID: mdl-34396623

OBJECTIVE: Cell-free DNA (cfDNA) screening assesses both maternal and placental cfDNA. Fibroids are common and release cfDNA into maternal serum. Genetic abnormality is seen in 50% of fibroids. We aimed to assess the impact of fibroids on the accuracy of genome-wide cfDNA screening. METHODS: This was a prospective cohort study of singleton pregnancies examined at one of two centers in Melbourne and Sydney, Australia, between 1 November 2019 and 31 December 2020. All cases underwent pretest ultrasound examination to confirm an ongoing pregnancy of at least 10 weeks' gestation, and, at this stage, the number and volume of any uterine fibroid were documented. Genome-wide cfDNA screening was performed to detect all copy-number variants (CNV) > 7 megabases. The incidence of a false-positive result was compared between cases with and those without fibroids. RESULTS: Over the 14-month study period, 13 184 patients underwent cfDNA screening, of whom 1017 (7.7%) had fibroids. Fibroids were not identified in any of the 17 participants who had a false-positive result for chromosomes 13, 18, 21, X or Y. Ninety-five (0.7%) cases were screen-positive for subchromosomal aberration (SA), rare autosomal trisomy (RAT) or multiple abnormalities (MA), with 10 of these cases having a fetal genetic abnormality. The incidence of a false-positive RAT, MA or SA result was significantly higher in participants with fibroids (20/1017 (2.0%)) than in those without fibroids (64/12 167 (0.5%)). Women with fibroids were approximately six times as likely to have a false-positive result for SA, and this was associated positively with both fibroid number and volume. CONCLUSIONS: Most women with fibroids do not have an abnormal result on genome-wide cfDNA screening. However, CNVs due to fibroids are associated with false-positive SA findings, although fibroids do not appear to influence cfDNA screening accuracy for the common autosomal trisomies or sex-chromosomal abnormalities. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Cell-Free Nucleic Acids/blood , Chromosome Disorders/diagnosis , Leiomyoma/genetics , Noninvasive Prenatal Testing/statistics & numerical data , Uterine Neoplasms/genetics , Adult , Australia , Chromosome Aberrations/statistics & numerical data , Chromosome Disorders/embryology , DNA Copy Number Variations , False Positive Reactions , Female , Humans , Pregnancy , Prospective Studies
13.
J Fr Ophtalmol ; 43(9): 929-943, 2020 Nov.
Article Fr | MEDLINE | ID: mdl-32778347

Phacoemulsification is the most frequently performed surgery in the world. Over the past few years, this surgery seems to have reached a plateau with no further innovative breakthroughs. In this paper, we focus on alternatives techniques, the latest innovations, and the research and development pipeline in this field.


Cataract Extraction , Cataract , Laser Therapy , Lens, Crystalline , Ophthalmology , Phacoemulsification , Cataract/diagnosis , Cataract/epidemiology , Humans
14.
Clin Exp Immunol ; 195(1): 1-9, 2019 01.
Article En | MEDLINE | ID: mdl-30307604

The objective of this study was to test the capacity of a newly developed fusion protein of interleukin 4 (IL-4) and IL-10 [IL4-10 fusion protein (FP)] to shift multiple pro-inflammatory pathways towards immune regulation, and to inhibit pro-inflammatory activity in arthritis models. The effects of IL4-10 FP in comparison with IL-4, IL-10 and IL-4 plus IL-10 on pro- and anti-inflammatory mediators, T cells and immunoglobulin (Ig) receptors in favour of immunoregulatory activity were studied. In addition, the capacity of IL4-10 FP to inhibit pro-inflammatory activity in ex-vivo and in-vivo arthritis models was investigated. IL4-10 FP robustly inhibited pro-inflammatory cytokine [IL-1ß, tumour necrosis factor (TNF)-α, IL-6 and IL-8] production in whole blood cultures, mediated by both the IL-10 and the IL-4 moiety. IL4-10 fusion protein induced IL-1 receptor antagonist (IL-1RA) production and preserved soluble TNF receptor (sTNFR) levels, strongly increasing IL-1RA/IL-1ß and sTNFR/TNF-α ratios. In addition, IL4-10 FP strongly inhibited T helper (Th) type 1 and 17 cytokine secretion, while maintaining FoxP3 expression and up-regulating Th2 activity. In addition, while largely leaving expression of activating Fc gamma receptor (FcγR)I, III and Fc epsilon receptor (FcεR) unaffected, it significantly shifted the FcγRIIa/FcγRIIb ratio in favour of the inhibitory FcγRIIb. Moreover, IL4-10 FP robustly inhibited secretion of pro-inflammatory cytokines by rheumatoid arthritis synovial tissue and suppressed experimental arthritis in mice, without inducing B cell hyperactivity. IL4-10 fusion protein is a novel drug, signalling cells to induce immunoregulatory activity that overcomes limitations of IL-4 and IL-10 stand-alone therapy, and therefore has therapeutic potential for inflammatory diseases such as rheumatoid arthritis.


Arthritis, Rheumatoid/therapy , Immunotherapy/methods , Inflammation/therapy , Interleukin-10/immunology , Interleukin-4/therapeutic use , Leukocytes, Mononuclear/immunology , Recombinant Fusion Proteins/therapeutic use , Animals , Arthritis, Rheumatoid/chemically induced , Arthritis, Rheumatoid/immunology , Cell Proliferation , Cells, Cultured , Disease Models, Animal , Female , Flow Cytometry , Humans , Immunomodulation , Inflammation/immunology , Interleukin-4/genetics , Lipopolysaccharides/immunology , Mice , Mice, Inbred BALB C , Proteoglycans , Recombinant Fusion Proteins/genetics , Synovial Membrane/metabolism , Synovial Membrane/pathology
15.
Nat Biomed Eng ; 2: 649-656, 2018 Jun 18.
Article En | MEDLINE | ID: mdl-30263872

Microsurgery of the retina would be dramatically improved by instruments that offer supra-human precision. Here, we report the results of a first-in-human study of remotely controlled robot-assisted retinal surgery performed through a telemanipulation device. Specifically, 12 patients requiring dissection of the epiretinal or inner limiting membrane over the macula were randomly assigned to either undergo robot-assisted-surgery or manual surgery, under general anaesthesia. We evaluated surgical success, duration of surgery and amount of retinal microtrauma as a proxy for safety. Surgical outcomes were equally successful in the robotic-surgery and manual-surgery groups. Differences in the amount of retinal microtrauma between the two groups were statistically insignificant, yet dissection took longer with robotic surgery (median time, 4 min 5 s) than with manual surgery (1 min 20 s). We also show the feasibility of using the robot to inject recombinant tissue plasminogen activator under the retina to displace sight-threatening haemorrhage in three patients under local anaesthesia. A safe and viable robotic system for intraocular surgery would enable precise and minimally traumatic delivery of gene therapy or cell therapy to the retina.

16.
Eur Radiol ; 28(7): 2951-2959, 2018 Jul.
Article En | MEDLINE | ID: mdl-29460076

OBJECTIVES: To evaluate the impact of digital detector, dose level and post-processing on neonatal chest phantom X-ray image quality (IQ). METHODS: A neonatal phantom was imaged using four different detectors: a CR powder phosphor (PIP), a CR needle phosphor (NIP) and two wireless CsI DR detectors (DXD and DRX). Five different dose levels were studied for each detector and two post-processing algorithms evaluated for each vendor. Three paediatric radiologists scored the images using European quality criteria plus additional questions on vascular lines, noise and disease simulation. Visual grading characteristics and ordinal regression statistics were used to evaluate the effect of detector type, post-processing and dose on VGA score (VGAS). RESULTS: No significant differences were found between the NIP, DXD and CRX detectors (p>0.05) whereas the PIP detector had significantly lower VGAS (p< 0.0001). Processing did not influence VGAS (p=0.819). Increasing dose resulted in significantly higher VGAS (p<0.0001). Visual grading analysis (VGA) identified a detector air kerma/image (DAK/image) of ~2.4 µGy as an ideal working point for NIP, DXD and DRX detectors. CONCLUSIONS: VGAS tracked IQ differences between detectors and dose levels but not image post-processing changes. VGA showed a DAK/image value above which perceived IQ did not improve, potentially useful for commissioning. KEY POINTS: • A VGA study detects IQ differences between detectors and dose levels. • The NIP detector matched the VGAS of the CsI DR detectors. • VGA data are useful in setting initial detector air kerma level. • Differences in NNPS were consistent with changes in VGAS.


Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Radiation Dosage , Radiography, Thoracic/instrumentation , Radiography, Thoracic/methods , Algorithms , Humans , Infant, Newborn
17.
Br J Radiol ; 91(1083): 20170714, 2018 Feb.
Article En | MEDLINE | ID: mdl-29212356

OBJECTIVE: The purpose of this study was to correlate the total dysphagia risk score (TDRS) with swallowing function as measured by videofluoroscopy of swallowing using the swallowing performance scale (SPS) and the penetration aspiration scale (PAS). METHODS: 63 patients from two different centres treated with radiotherapy for head and neck cancer were evaluated in the current study. Swallowing videofluoroscopies at baseline, 6 and 12 months following radiotherapy were evaluated by two observers. The TDRS of all patients was calculated and correlated with the consensus PAS and SPS scores of the two observers. RESULTS: Regarding the PAS scale, we did not observe a significant correlation with the TDRS. Regarding SPS, we found a significant correlation at 6 months (p = 0.01) and a borderline significant correlation at 12 months (p = 0.05). We observed statistically lower SPS scores for patients in the intermediate-risk category when compared to the high-risk category. When we compared low vs high TDRS risk patients, we did not observe a significant difference regarding SPS scores. When comparing low- vs intermediate-risk patients, we observed higher SPS scores in the low-risk group (p = 0.01). When the low- and intermediate-risk patients were grouped together, we observed less swallowing problems as measured by SPS in the low and intermediate group when compared to the high-risk group (p = 0.05) at 6 months. CONCLUSION: Patients with high-risk TDRS scores have higher SPS scores when compared to the intermediate group and the intermediate- and low-risk group together. However, low-risk patients in our patient cohort could not be distinguished from high or intermediate-risk patients. Advances in knowledge: TDRS was never correlated with videofluoroscopies in past studies. The hypothesis of this paper was to see if the TDRS could guide us to see which patients are at risk for high scores on SPS and PAS and might need a videofluoroscopic examination in the follow up. Given the poor correlations in our study, however, we cannot recommend the use of the TDRS to select patients who might benefit from the additional information provided by videofluoroscopies.


Deglutition Disorders/diagnostic imaging , Deglutition Disorders/etiology , Fluoroscopy , Head and Neck Neoplasms/radiotherapy , Video Recording , Adult , Aged , Aged, 80 and over , Contrast Media , Female , Humans , Iohexol/analogs & derivatives , Male , Middle Aged , Prospective Studies , Retrospective Studies , Risk Assessment , Risk Factors
18.
BJOG ; 125(7): 848-855, 2018 Jun.
Article En | MEDLINE | ID: mdl-29090507

OBJECTIVE: To investigate the pregnancy outcomes in a cohort of women who failed to obtain a result in non-invasive prenatal testing (NIPT). DESIGN: Historical cohort study. SETTING: A multicentre private practice in Sydney, Australia. POPULATION: Women who failed to obtain a result from NIPT (n = 131). METHODS: The maternal characteristics, antenatal investigations and pregnancy outcomes for these women were compared with those who obtained a result at the same practice and to the general Australian obstetric population. MAIN OUTCOME MEASURES: Antenatal investigations: pregnancy-associated plasma protein-A (PAPP-A), free ß-human chorionic gonadotrophin (ß-hCG), placental growth factor (PlGF), uterine artery pulsatility index (PI), mean arterial pressure (MAP). Pregnancy outcomes: chromosomal abnormality, pre-eclampsia, gestational diabetes, small-for-gestational-age (SGA), preterm delivery. RESULTS: Only 1.1% of NIPT samples failed to return a result. This cohort was significantly older and had significantly increased weight compared with the general Australian obstetric population. Pregnancy outcomes were available for 94% of the cohort. There were significantly higher rates of chromosomal aneuploidies (6.5% versus 0.2%, P < 0.0001), pre-eclampsia (11% versus 1.5%, P < 0.0001) and gestational diabetes (23% versus 7.5%, P < 0.0001) compared with the general obstetric population. Rates of preterm delivery and SGA were elevated but did not reach significance. Antenatal investigations demonstrated decreased PAPP-A MoM (0.75 versus 1.14, P < 0.0001), decreased free ß-hCG (0.71 versus 1.01, P < 0.0001) and increased uterine artery PI (1.79 versus 1.65, P = 0.02). CONCLUSION: Women who fail to obtain a result from NIPT are at increased risk of adverse pregnancy outcomes, in particular chromosomal aneuploidy, gestational diabetes and pre-eclampsia. FUNDING: None received. TWEETABLE ABSTRACT: Women who fail to obtain a result from cell-free DNA NIPT are at increased risk of adverse pregnancy outcomes.


Cell-Free Nucleic Acids/blood , Diagnostic Errors/statistics & numerical data , Maternal Serum Screening Tests/statistics & numerical data , Arterial Pressure , Chorionic Gonadotropin, beta Subunit, Human/blood , Chromosome Aberrations/statistics & numerical data , Cohort Studies , Diabetes, Gestational/diagnosis , Diabetes, Gestational/epidemiology , Female , Humans , Infant, Small for Gestational Age , Maternal Serum Screening Tests/methods , New South Wales , Placenta Growth Factor/blood , Pre-Eclampsia/diagnosis , Pre-Eclampsia/epidemiology , Pregnancy , Pregnancy Outcome , Pregnancy-Associated Plasma Protein-A/analysis , Premature Birth/diagnosis , Premature Birth/epidemiology , Pulsatile Flow , Ultrasonography, Prenatal , Uterine Artery/diagnostic imaging
19.
Phys Med Biol ; 62(24): N573-N586, 2017 Nov 21.
Article En | MEDLINE | ID: mdl-29064378

Physical image quality of five x-ray detectors used in the paediatric imaging department is characterized with the aim of establishing the range/scope of imaging performance provided by these detectors for neonatal imaging. Two computed radiography (CR) detectors (MD4.0 powder imaging plate (PIP) and HD5.0 needle imaging plate (NIP), Agfa HealthCare NV, B-2640 Mortsel, Belgium) and three flat panel detectors (FPD) (the Agfa DX-D35C and DX-D45C and the DRX-2530C (Carestream Health Inc., Rochester, NY 14608, USA)) were assessed. Physical image quality was characterized using the detector metrics given by the International Electrotechnical Commission (IEC 62220-1) to measure modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) using the IEC-specified beam qualities of RQA3 and RQA5. The DQE was evaluated at the normal operating detector air kerma (DAK) level, defined at 2.5 µGy for all detectors, and at factors of 1/3.2 and 3.2 times the normal level. MTF curves for the different detectors were similar at both RQA3 and RQA5 energies; the average spatial frequency for the 50% point (MTF0.5) at RQA3 was 1.26 mm-1, with a range from 1.20 mm-1 to 1.37 mm-1. The DQE of the NIP CR compared to the PIP CR was notably greater and similar to that for the FPD devices. At RQA3, average DQE for the FPD and NIP (at 0.5 mm-1; 2.5 µGy) was 0.57 compared to 0.26 for the PIP CR. At the RQA5 energy, the DRX-2530C and the DX-D45C had the highest DQE (~0.6 at 0.5 mm-1; 2.5 µGy). Noise separation analysis using the polynomial model showed higher electronic noise for the DX-D35C and DRX-2530C detectors; this explains the reduced DQE seen at 0.7 µGy/image. The NIP CR detector offers notably improved DQE performance compared to the PIP CR system and a value similar to the DQE for FPD devices at the RQA3 energy.


Radiographic Image Enhancement/methods , Child , Humans , Models, Statistical , Signal-To-Noise Ratio
20.
Carbohydr Polym ; 165: 229-237, 2017 Jun 01.
Article En | MEDLINE | ID: mdl-28363545

Certain lipophilic components can be inserted very efficiently as guest molecule in the existing single helical amylose cavities in VH-type crystalline granular cold-water swelling starch (GCWSS). In the present study, ascorbyl palmitate (AscP) was used as a model guest compound. The impacts of temperature (20 and 60°C) and ethanol [48 and 68% (v/v)] and AscP [1.0, 2.5, 5.0, 10.0% (w/w)] concentrations on encapsulation performance were investigated. First, native maize and potato starches were converted into VH-type GCWSS by aqueous ethanol [48% (v/v)] treatment at 95°C. Exposing GCWSS to AscP induced the formation of inclusion complexes when a particular solvent (and temperature) environment was met. In 48% (v/v) ethanol, raising the treatment temperature to 60°C did not significantly impact on the encapsulation performance. Maximum degrees of AscP encapsulation were 2.9 and 1.5% (w/w) for maize and potato starch, respectively, as determined by proton nuclear magnetic resonance measurements. As maize GCWSS contained more 'parent' VH-type crystals, it was capable of entrapping more AscP than potato GCWSS.

...