Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
J Clin Monit Comput ; 2024 Aug 16.
Article in English | MEDLINE | ID: mdl-39150462

ABSTRACT

Blood velocities measured by Transcranial Doppler (TCD) are dependent on the angle between the incident ultrasound beam and the direction of blood flow (known as the Doppler angle). However, when TCD examinations are performed without imaging the Doppler angle for each vessel segment is not known. We have measured Doppler angles in the basal cerebral arteries examined with TCD using three-dimensional (3D) vessel models generated from computed tomography angiography (CTA) scans. This approach produces angle statistics that are not accessible during non-imaging TCD studies. We created 3D models of the basal cerebral arteries for 24 vasospasm patients. Standard acoustic windows were mapped to the specific anatomy of each patient. Virtual ultrasound transmit beams were generated that originated from the acoustic window and intersected the centerline of each arterial segment. Doppler angle measurements were calculated and compiled for each vessel segment. Doppler angles were smallest for the middle cerebral artery M1 segment (median 24.6°) and ophthalmic artery (median 25.0°), and largest for the anterior cerebral artery A2 segment (median 76.4°) and posterior cerebral artery P2 segment (median 75.8°). The ophthalmic artery had the highest proportion of Doppler angles that were less than 60° (99%) while the anterior cerebral artery A2 segment had the lowest proportion of Doppler angles that were less than 60° (10%). These angle measurements indicate the expected deviation between measured and true velocities in the cerebral arteries, highlighting specific segments that may be prone to underestimation of velocity.

2.
Ann Biomed Eng ; 52(9): 2417-2439, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38758460

ABSTRACT

The Circle of Willis (CoW) is a ring-like network of blood vessels that perfuses the brain. Flow in the collateral pathways that connect major arterial inputs in the CoW change dynamically in response to vessel narrowing or occlusion. Vasospasm is an involuntary constriction of blood vessels following subarachnoid hemorrhage (SAH), which can lead to stroke. This study investigated interactions between localization of vasospasm in the CoW, vasospasm severity, anatomical variations, and changes in collateral flow directions. Patient-specific computational fluid dynamics (CFD) simulations were created for 25 vasospasm patients. Computed tomographic angiography scans were segmented capturing the anatomical variation and stenosis due to vasospasm. Transcranial Doppler ultrasound measurements of velocity were used to define boundary conditions. Digital subtraction angiography was analyzed to determine the directions and magnitudes of collateral flows as well as vasospasm severity in each vessel. Percent changes in resistance and viscous dissipation were analyzed to quantify vasospasm severity and localization of vasospasm in a specific region of the CoW. Angiographic severity correlated well with percent changes in resistance and viscous dissipation across all cerebral vessels. Changes in flow direction were observed in collateral pathways of some patients with localized vasospasm, while no significant changes in flow direction were observed in others. CFD simulations can be leveraged to quantify the localization and severity of vasospasm in SAH patients. These factors as well as anatomical variation may lead to changes in collateral flow directions. Future work could relate localization and vasospasm severity to clinical outcomes like the development of infarct.


Subject(s)
Cerebrovascular Circulation , Circle of Willis , Models, Cardiovascular , Vasospasm, Intracranial , Humans , Circle of Willis/physiopathology , Circle of Willis/diagnostic imaging , Vasospasm, Intracranial/physiopathology , Vasospasm, Intracranial/diagnostic imaging , Female , Male , Middle Aged , Hydrodynamics , Aged , Collateral Circulation , Adult
3.
Ann Biomed Eng ; 52(6): 1763-1778, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38517620

ABSTRACT

Patients with advanced heart failure are implanted with a left ventricular assist device (LVAD) as a bridge-to-transplantation or destination therapy. Despite advances in pump design, the risk of stroke remains high. LVAD implantation significantly alters intraventricular hemodynamics, where regions of stagnation or elevated shear stresses promote thrombus formation. Third generation pumps incorporate a pulsatility mode that modulates rotational speed of the pump to enhance in-pump washout. We investigated how the timing of the pulsatility mode with the cardiac cycle affects intraventricular hemodynamic factors linked to thrombus formation. Computational fluid dynamics simulations with Lagrangian particle tracking to model platelet behavior in a patient-specific left ventricle captured altered intraventricular hemodynamics due to LVAD implantation. HeartMate 3 incorporates a pulsatility mode that modulates the speed of the pump every two seconds. Four different timings of this pulsatility mode with respect to the cardiac cycle were investigated. A strong jet formed between the mitral valve and inflow cannula. Blood stagnated in the left ventricular outflow tract beneath a closed aortic valve, in the near-wall regions off-axis of the jet, and in a large counterrotating vortex near the anterior wall. Computational results showed good agreement with particle image velocimetry results. Synchronization of the pulsatility mode with peak systole decreased stasis, reflected in the intraventricular washout of virtual contrast and Lagrangian particles over time. Temporal synchronization of HeartMate 3 pulsatility with the cardiac cycle reduces intraventricular stasis and could be beneficial for decreasing thrombogenicity.


Subject(s)
Heart-Assist Devices , Hemodynamics , Models, Cardiovascular , Humans , Heart Ventricles , Computer Simulation , Thrombosis/physiopathology , Heart Failure/physiopathology
4.
J Biomech Eng ; 145(4)2023 04 01.
Article in English | MEDLINE | ID: mdl-36173034

ABSTRACT

The Circle of Willis (CoW) is a redundant network of blood vessels that perfuses the brain. The ringlike anatomy mitigates the negative effects of stroke by activating collateral pathways that help maintain physiological perfusion. Previous studies have investigated the activation of these pathways during embolic stroke and internal carotid artery occlusion. However, the role of collateral pathways during cerebral vasospasm-an involuntary constriction of blood vessels after subarachnoid hemorrhage-is not well-documented. This study presents a novel technique to create patient-specific computational fluid dynamics (CFD) simulations of the Circle of Willis before and during vasospasm. Computed tomographic angiography (CTA) scans are segmented to model the vasculature, and transcranial Doppler ultrasound (TCD) measurements of blood flow velocity are applied as boundary conditions. Bayesian analysis leverages information about the uncertainty in the measurements of vessel diameters and velocities to find an optimized parameter set that satisfies mass conservation and that is applied in the final simulation. With this optimized parameter set, the diameters, velocities, and flow rates fall within typical literature values. Virtual angiograms modeled using passive scalar transport agree closely with clinical angiography. A sensitivity analysis quantifies the changes in collateral flow rates with respect to changes in the inlet and outlet flow rates. This analysis can be applied in the future to a cohort of patients to investigate the relationship between the locations and severities of vasospasm, the patient-to-patient anatomical variability in the Circle of Willis, and the activation of collateral pathways.


Subject(s)
Circle of Willis , Hydrodynamics , Circle of Willis/diagnostic imaging , Bayes Theorem , Collateral Circulation/physiology , Cerebrovascular Circulation/physiology , Blood Flow Velocity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL