Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
Article in English | MEDLINE | ID: mdl-38864969

ABSTRACT

PURPOSE: Coronary artery bypass grafting (CABG) on cardiopulmonary bypass (CPB) is associated with myocardial ischemia-reperfusion injury (IRI), which may limit the benefit of the surgery. Both experimental and clinical studies suggest that Intralipid, a lipid emulsion commonly used for parenteral nutrition, can limit myocardial IRI. We therefore aimed to investigate whether Intralipid administered at reperfusion can reduce myocardial IRI in patients undergoing CABG on CPB. METHODS: We conducted a randomized, double-blind, pilot trial in which 29 adult patients scheduled for CABG were randomly assigned (on a 1:1 basis) to receive either 1.5 ml/kg Intralipid 20% or Ringer's Lactate 3 min before aortic cross unclamping. The primary endpoint was the 72-h area under the curve (AUC) for troponin I. RESULTS: Of the 29 patients randomized, 26 were included in the study (two withdrew consent and one was excluded before surgery). The 72-h AUC for troponin I did not significantly differ between the control and Intralipid group (546437 ± 205518 versus 487561 ± 115724 arbitrary units, respectively; P = 0.804). Other outcomes (including 72-h AUC for CK-MB, C-reactive protein, need for defibrillation, time to extubation, length of ICU and hospital stay, and serious adverse events) were similar between the two groups. CONCLUSION: In patients undergoing CABG on CPB, Intralipid did not limit myocardial IRI compared to placebo. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02807727 (registration date: 16 June 2016).

4.
Front Cardiovasc Med ; 9: 791949, 2022.
Article in English | MEDLINE | ID: mdl-35310972

ABSTRACT

Leaflet durability and costs restrict contemporary trans-catheter aortic valve replacement (TAVR) largely to elderly patients in affluent countries. TAVR that are easily deployable, avoid secondary procedures and are also suitable for younger patients and non-calcific aortic regurgitation (AR) would significantly expand their global reach. Recognizing the reduced need for post-implantation pacemakers in balloon-expandable (BE) TAVR and the recent advances with potentially superior leaflet materials, a trans-catheter BE-system was developed that allows tactile, non-occlusive deployment without rapid pacing, direct attachment of both bioprosthetic and polymer leaflets onto a shape-stabilized scallop and anchorage achieved by plastic deformation even in the absence of calcification. Three sizes were developed from nickel-cobalt-chromium MP35N alloy tubes: Small/23 mm, Medium/26 mm and Large/29 mm. Crimp-diameters of valves with both bioprosthetic (sandwich-crosslinked decellularized pericardium) and polymer leaflets (triblock polyurethane combining siloxane and carbonate segments) match those of modern clinically used BE TAVR. Balloon expansion favors the wing-structures of the stent thereby creating supra-annular anchors whose diameter exceeds the outer diameter at the waist level by a quarter. In the pulse duplicator, polymer and bioprosthetic TAVR showed equivalent fluid dynamics with excellent EOA, pressure gradients and regurgitation volumes. Post-deployment fatigue resistance surpassed ISO requirements. The radial force of the helical deployment balloon at different filling pressures resulted in a fully developed anchorage profile of the valves from two thirds of their maximum deployment diameter onwards. By combining a unique balloon-expandable TAVR system that also caters for non-calcific AR with polymer leaflets, a powerful, potentially disruptive technology for heart valve disease has been incorporated into a TAVR that addresses global needs. While fulfilling key prerequisites for expanding the scope of TAVR to the vast number of patients of low- to middle income countries living with rheumatic heart disease the system may eventually also bring hope to patients of high-income countries presently excluded from TAVR for being too young.

6.
Anesth Analg ; 131(5): 1401-1408, 2020 11.
Article in English | MEDLINE | ID: mdl-33079862

ABSTRACT

BACKGROUND: Hypertension is a common risk factor for cardiovascular morbidity and mortality, with a high prevalence in patients presenting for elective surgery. In limited resource environments, patients have poor access to primary care physicians, limiting the efficacy of lifestyle modification for the management of hypertension. In these circumstances, the perioperative period presents a unique opportunity for diagnosis and initiation and/or modification of pharmacotherapy of hypertension. Anesthesiologists are ideally placed to lead this aspect of perioperative medicine. The study objective was for anesthesiologists to identify patients at the preoperative visit with previously undiagnosed or poorly controlled chronic hypertension and follow a simple management algorithm. METHODS: In collaboration with expert physicians, we designed and implemented an algorithm for the diagnosis and management of chronic hypertension. This was a multicenter, cross-sectional quality improvement project in 7 hospitals in the Western Cape, South Africa. On the day before scheduled elective surgery, adult in-patients had 2 sets of blood pressure (BP) readings taken, one by nurses and the other by anesthesiologists, using a noninvasive automated BP device. These were averaged on an electronic database, to diagnose hypertension. Patients with normal BP or well-controlled hypertension required no further management. Those with borderline BP received educational pamphlets. Patients with stage 1 or 2 hypertension were managed with medication according to the algorithm, starting 1 day postoperatively, and provided with educational pamphlets. Patients with stage 3 disease had their surgery postponed and were referred to a physician. The primary outcome was adherence by the anesthesiologist to the algorithm in the diagnosis and management of hypertension. An 80% adherence rate was considered successful implementation. The secondary outcome was the adherence to the algorithm at discharge. RESULTS: Two hundred ninety-eight patients were screened for hypertension. One hundred six patients were eligible for the quality improvement project. Thirty-seven (34.9%) had borderline BP readings, 43 (40.6%) had stage 1, 22 (20.8%) stage 2, and 4 (3.8%) stage 3 hypertension, respectively. The adherence rate by the anesthesiologist in initiating treatment according to the algorithm was 89 of 106 (84.0%; 95% confidence interval [CI, 77.0-91.0). There was full adherence to the algorithm in 59 of 106 (55.5%; 95% CI, 46.2-65.1) at the time of discharge from hospital. CONCLUSIONS: Anesthesiologists successfully implemented a quality improvement project for diagnosis and management of hypertension in the perioperative period. This has the potential to reduce the public health burden of hypertension in limited resource environments. Successful ongoing prescription and follow-up requires cooperation within a multidisciplinary team.


Subject(s)
Algorithms , Anesthesiologists , Hypertension/therapy , Perioperative Care/standards , Quality Improvement , Blood Pressure , Chronic Disease , Cross-Sectional Studies , Databases, Factual , Female , Guideline Adherence , Humans , Hypertension/diagnosis , Hypertension/epidemiology , Male , Middle Aged , Prevalence , South Africa/epidemiology
7.
Curr Opin Anaesthesiol ; 33(1): 83-91, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31789893

ABSTRACT

PURPOSE OF REVIEW: Transesophageal echocardiography (TEE) has made its way into the cardiac surgery realm and spurred the development of many interventions. In the domain of minimally invasive cardiac surgery (MICS), TEE has become central to reducing cardiovascular complications. RECENT FINDINGS: Real-time three-dimensional TEE is a key contributor to the safe and precise deployment of the PASCAL mitral valve repair system, which is showing great potential in ongoing studies. The current data on outcomes of transcatheter aortic valve replacement show that preprocedural three-dimensional TEE and multidetector computed tomography (CT) perform similarly in aortic root assessment. Three-dimensional color Doppler TEE has been suggested to be more appropriate in quantifying residual mitral regurgitation and evaluating the success of surgical or percutaneous closure. A three-dimensional TEE-derived aortomitral angle may be valuable in predicting and detecting dynamic left ventricular outflow tract obstruction, thereby enhancing the safety of transcatheter mitral valve replacement. SUMMARY: Advanced imaging modalities are essential for the sustained growth of MICS, particularly with the evolution of novel transcatheter systems. These techniques rely on exceptional imaging quality at all stages of the perioperative period to modify surgical-risk and improve patient outcomes. TEE has the additional benefit of providing real-time information on intrathoracic structures to guide intraoperative management.


Subject(s)
Cardiac Surgical Procedures , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Mitral Valve Insufficiency , Cardiac Surgical Procedures/methods , Humans , Minimally Invasive Surgical Procedures , Mitral Valve Insufficiency/surgery
8.
EuroIntervention ; 15(11): e975-e982, 2019 Dec 06.
Article in English | MEDLINE | ID: mdl-31403458

ABSTRACT

AIMS: Cardiac surgery in middle-income countries differs significantly from that in high-income countries regarding prevailing heart valve pathologies and access to cardiac surgery. Typically, rheumatic aortic regurgitation in the absence of calcification by far outweighs stenosis. As such, entirely different transcatheter aortic valve implantation (TAVI) concepts are required for these regions. The aim of the study was to evaluate the five-month performance of the SAT (Strait Access Technologies, Cape Town, South Africa) pericardial TAVI system in the orthotopic aortic position of juvenile sheep. METHODS AND RESULTS: A self-homing, non-occlusive balloon-expandable TAVI system comprising a hollow balloon, stabilising locator trunks, a scalloped CoCr stent with elevating anchorage arms and decellularised, sandwich-crosslinked pericardium was compared with control surgical valves (Edwards PERIMOUNT) in sheep. The implantation period was five months. The tactile placement of the TAVI valves was accomplished without the need for rapid pacing. At termination, no structural degeneration was observed in either group. The TAVIs were well healed with the stent struts largely embedded in tissue. Correlating with sheep growth (weight gain of 40.4±13.0%) during the implantation period, mean transvalvular gradients increased from 3.08±1.95 mmHg to 8.50±5.38 mmHg (p=0.044) after five months. CONCLUSIONS: A single-stage, balloon-expandable, easy to place TAVI system with antigen-depleted and antigen-masked bioprosthetic leaflets promises to address the distinct needs of low- and middle-income countries with regard to TAVI better than conventional systems.


Subject(s)
Rheumatic Heart Disease , Transcatheter Aortic Valve Replacement , Animals , Aortic Valve , Aortic Valve Stenosis , Patients , Prosthesis Design , Rheumatic Heart Disease/complications , Sheep , South Africa , Treatment Outcome
9.
Anesth Analg ; 128(6): 1208-1216, 2019 06.
Article in English | MEDLINE | ID: mdl-31094790

ABSTRACT

BACKGROUND: Pilot studies applying point-of-care ultrasound (POCUS) in preeclampsia indicate the presence of pulmonary interstitial edema, cerebral edema, and cardiac dysfunction. Laboratory markers of oncotic pressure (albumin) and cardiac dysfunction (brain natriuretic peptide [BNP]) may be abnormal, but the clinical application remains unclear. We investigated the prevalence of pulmonary interstitial syndrome (PIS), cardiac dysfunction, and increased optic nerve sheath diameter (ONSD) in late-onset preeclampsia with severe features. The primary aim was to examine the association between PIS or ONSD and maternal serum albumin level. The secondary aims were to explore the association between cardiac dysfunction and PIS, ONSD, BNP, and serum albumin level and between POCUS-derived parameters and a suspicious or pathological cardiotocograph. METHODS: Ninety-five women were enrolled in this prospective observational cohort study. A POCUS examination of lungs, heart, and ONSD was performed. PIS was defined as a bilateral B-line pattern on lung ultrasound and diastolic dysfunction according to an algorithm of the American Society of Echocardiography. ONSD >5.8 mm was interpreted as compatible with raised intracranial pressure (>20 mm Hg). Serum BNP and albumin levels were also measured. RESULTS: PIS, diastolic dysfunction, systolic dysfunction, and raised left ventricular end-diastolic pressure (LVEDP) were present in 23 (24%), 31 (33%), 9 (10%), and 20 (25%) women, respectively. ONSD was increased in 27 (28%) women. Concerning the primary outcome, there was no association between albumin level and PIS (P = .4) or ONSD (P = .63). With respect to secondary outcomes, there was no association between albumin level and systolic dysfunction (P = .21) or raised LVEDP (P = .44). PIS was associated with diastolic dysfunction (P = .02) and raised LVEDP (P = .009; negative predictive value, 85%). BNP level was associated with systolic (P < .001) and diastolic dysfunction (P = .003) and LVEDP (P = .007). No association was found between POCUS abnormalities and a suspicious/pathological cardiotocograph (P = .07). CONCLUSIONS: PIS, diastolic dysfunction, and increased ONSD were common in preeclampsia with severe features. Cardiac ultrasound abnormalities may be more useful than albumin levels in predicting PIS. The absence of PIS may exclude raised LVEDP. The further clinical relevance of PIS and raised ONSD remains to be established. BNP level was associated with cardiac ultrasound abnormalities. Although this study was not designed to directly influence clinical management, the findings suggest that POCUS may serve as a useful adjunct to clinical examination for the obstetric anesthesiologist managing these complex patients.


Subject(s)
Heart/diagnostic imaging , Natriuretic Peptide, Brain/blood , Point-of-Care Systems , Pre-Eclampsia/blood , Serum Albumin/analysis , Ultrasonography, Prenatal , Adult , Algorithms , Cardiotocography , Echocardiography , Female , Heart Defects, Congenital/blood , Heart Ventricles , Humans , Incidence , Intracranial Pressure , Lung/diagnostic imaging , Lung Diseases/blood , Observer Variation , Optic Nerve/pathology , Predictive Value of Tests , Pregnancy , Prevalence , Prospective Studies , Ventricular Dysfunction, Left/physiopathology
10.
Anesth Analg ; 129(2): 444-449, 2019 08.
Article in English | MEDLINE | ID: mdl-29878938

ABSTRACT

BACKGROUND: The increasing prevalence of obesity worldwide is a major threat to global health. Cardiac structural and functional changes are well documented for obesity as well as for pregnancy, but there is limited literature on morbidly obese parturients. We hypothesized that there are both cardiac structural and functional differences between morbidly obese pregnant women and pregnant women of normal body mass index (BMI). METHODS: This prospective cross-sectional study was performed in 2 referral maternity units in Cape Town, South Africa, over a 3-month period. Forty morbidly obese pregnant women of BMI ≥40 kg·m (group O) were compared to 45 pregnant women of BMI ≤30 kg·m (group N). Cardiac structure and function were assessed by transthoracic echocardiography, according to the recommendations of the British Society of Echocardiography. The 2-sample t-test with unequal variances was used for the comparison of the mean values between the groups. RESULTS: Acceptable echocardiographic images were obtained in all obese women. Statistical significance was defined as P < .0225 after applying the Benjamini-Hochberg correction for multiple testing. Mean (standard deviation) mean arterial pressure was higher in group O (91 [8.42] vs 84 [9.49] mm Hg, P < .001). There were no between-group differences in heart rate, stroke volume, or cardiac index (84 [12] vs 79 [13] beats·minute, P = .103; 64.4 [9.7] vs 59.5 [13.5] mL, P = .069; 2551 [474] vs 2729 [623] mL·minute·m, P = .156, for groups O and N, respectively). Stroke volume index was lower, and left ventricular mass was higher in group O (30.14 [4.51] vs 34.25 [7.00] mL·m, P = .003; 152 [24] vs 115 [29] g, P < .001). S' septal was lower in group O (8.43 [1.20] vs 9.25 [1.64] cm·second, P = .012). Considering diastolic function, isovolumetric relaxation time was significantly prolonged in group O (73 [15] vs 61 [15] milliseconds, P < .001). The septal tissue Doppler index E' septal was lower in group O (9.08 [1.69] vs 11.28 [3.18], P < .001). There were no between-group differences in E' average (10.7 [2.3] vs 12.0 [2.7], P = .018, O versus N) or E/E' average (7.85 [1.77] vs 7.27 [1.68], P = .137, O versus N). Right ventricular E'/A' was lower in group O (1.07 [0.47] vs 1.29 [0.32], P = .016). CONCLUSIONS: Cardiac index did not differ between obese pregnant women and those with normal BMI. Their increased left ventricular mass and lower stroke volume index could indicate a limited adaptive reserve. Obese women had minor decreases in septal left ventricular tissue Doppler velocity, but the E/E' average values did not suggest clinically significant diastolic dysfunction.


Subject(s)
Echocardiography, Doppler , Heart/diagnostic imaging , Hemodynamics , Obesity, Morbid/complications , Parturition , Pregnancy Complications, Cardiovascular/diagnostic imaging , Ventricular Function , Adaptation, Physiological , Adult , Body Mass Index , Cross-Sectional Studies , Female , Heart/physiopathology , Humans , Obesity, Morbid/diagnosis , Obesity, Morbid/physiopathology , Predictive Value of Tests , Pregnancy , Pregnancy Complications, Cardiovascular/etiology , Pregnancy Complications, Cardiovascular/physiopathology , Prospective Studies , South Africa , Stroke Volume , Ventricular Function, Left , Ventricular Function, Right , Ventricular Remodeling , Young Adult
11.
Echo Res Pract ; 5(4): R101-R113, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30303686

ABSTRACT

Transoesophageal echocardiography (TOE) has, in certain clinical situations, become an almost universal monitor and diagnostic tool. In the perioperative environment, TOE is frequently used to guide anaesthetic management and assist with surgical decision making for, but not limited to, cardiothoracic, major vascular and transplant operations. The use of TOE is not limited to the theatre environment being frequently used in outpatient clinics, emergency departments and intensive care settings. Two case reports, one of oesophageal perforation and another of TOE utilization in a patient having previously undergone an oesophagectomy, introduce the need for care while using TOE and highlight the need for vigilance. The safe use of TOE, the potential complications and the suggested contra-indications are then considered together with suggestions for improving the safety of TOE in adult and paediatric patients.

12.
Echo Res Pract ; 5(2): K47-K51, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29674478

ABSTRACT

SummaryWe present a patient with rheumatic heart disease involving all the heart valves. An intraoperative transoesophageal echocardiography confirmed severe mitral stenosis, severe aortic regurgitation, severe tricuspid regurgitation and stenosis, and severe pulmonary stenosis. The patient underwent successful quadruple valve replacement during a single operation at the Groote Schuur Hospital, Cape Town, South Africa. LEARNING POINTS: Rheumatic heart disease can affect all the heart valves including the pulmonary valve.Intraoperative transoesophageal echocardiography is key for diagnosis, monitoring and confirmation of successful surgical result during heart valve surgery.Combined surgical procedure of all four valves is possible though associated with long procedural time.

16.
S Afr Med J ; 106(6)2016 May 09.
Article in English | MEDLINE | ID: mdl-27245725

ABSTRACT

BACKGROUND: Meta-analyses of the implementation of a surgical safety checklist (SSC) in observational studies have shown a significant decrease in mortality and surgical complications. OBJECTIVE: To determine the efficacy of the SSC using data from randomised controlled trials (RCTs). METHODS: This meta-analysis followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines and was registered with PROSPERO (CRD42015017546). A comprehensive search of six databases was conducted using the OvidSP search engine. RESULTS: Four hundred and sixty-four citations revealed three eligible trials conducted in tertiary hospitals and a community hospital, with a total of 6 060 patients. All trials had allocation concealment bias and a lack of blinding of participants and personnel. A single trial that contributed 5 295 of the 6 060 patients to the meta-analysis had no detection, attrition or reporting biases. The SSC was associated with significantly decreased mortality (risk ratio (RR) 0.59, 95% confidence interval (CI) 0.42 - 0.85; p=0.0004; I2=0%) and surgical complications (RR 0.64, 95% CI 0.57 - 0.71; p<0.00001; I2=0%). The efficacy of the SSC on specific surgical complications was as follows: respiratory complications RR 0.59, 95% CI 0.21 - 1.70; p=0.33, cardiac complications RR 0.74, 95% CI 0.28 - 1.95; p=0.54, infectious complications RR 0.61, 95% CI 0.29 - 1.27; p=0.18, and perioperative bleeding RR 0.36, 95% CI 0.23 - 0.56; p<0.00001. CONCLUSIONS: There is sufficient RCT evidence to suggest that SSCs decrease hospital mortality and surgical outcomes in tertiary and community hospitals. However, randomised evidence of the efficacy of the SSC at rural hospital level is absent.

SELECTION OF CITATIONS