Results 1 - 20 de 38
Filter
2.
Phys Eng Sci Med ; 2024 May 16.
Article in English | MEDLINE | ID: mdl-38753285

ABSTRACT

This study aims to evaluate the output factors (OPF) of different radiation therapy planning systems (TPSs) using a plastic scintillator detector (PSD). The validation results for determining a practical field size for clinical use were verified. The implemented validation system was an Exradin W2 PSD. The focus was to validate the OPFs of the small irradiation fields of two modeled radiation TPSs using RayStation version 10.0.1 and Monaco version 5.51.10. The linear accelerator used for irradiation was a TrueBeam with three energies: 4, 6, and 10 MV. RayStation calculations showed that when the irradiation field size was reduced from 10 × 10 to 0.5 × 0.5 cm2, the results were within 2.0% of the measured values for all energies. Similarly, the values calculated using Monaco were within approximately 2.0% of the measured values for irradiation field sizes between 10 × 10 and 1.5 × 1.5 cm2 for all beam energies of interest. Thus, PSDs are effective validation tools for OPF calculations in TPS. A TPS modeled with the same source data has different minimum irradiation field sizes that can be calculated. These findings could aid in verification of equipment accuracy for treatment planning requiring highly accurate dose calculations and for third-party evaluation of OPF calculations for TPS.

3.
J Clin Med ; 13(6)2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38542005

ABSTRACT

Background: Our initial clinical study using simple diffusion kurtosis imaging (SDI), which simultaneously produces a diffusion kurtosis image (DKI) and an apparent diffusion coefficient map, confirmed the usefulness of SDI for tumor diagnosis. However, the obtained DKI had noticeable variability in the mean kurtosis (MK) values, which is inherent to SDI. We aimed to improve this variability in SDI by preprocessing with three different filters (Gaussian [G], median [M], and nonlocal mean) of the diffusion-weighted images used for SDI. Methods: The usefulness of filter parameters for diagnosis was examined in basic and clinical studies involving 13 patients with head and neck tumors. Results: The filter parameters, which did not change the median MK value, but reduced the variability and significantly homogenized the MK values in tumor and normal tissues in both basic and clinical studies, were identified. In the receiver operating characteristic curve analysis for distinguishing tumors from normal tissues using MK values, the area under curve values significantly improved from 0.627 without filters to 0.641 with G (σ = 0.5) and 0.638 with M (radius = 0.5). Conclusions: Thus, image pretreatment with G and M for SDI was shown to be useful for improving tumor diagnosis in clinical practice.

4.
Med Dosim ; 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38556401

ABSTRACT

Accurate information on set-up error during radiotherapy is essential for determining the optimal number of treatments in hypofractionated radiotherapy for prostate cancer. This necessitates careful control by the radiotherapy staff to assess the patient's condition. This study aimed to develop an evaluation method of the temporal trends in a patient's specific prostate movement during treatment using image matching and margin values. This study included 65 patients who underwent prostate volumetric modulated arc therapy (mean treatment time, 87.2 s). Set-up errors were assessed using bone, inter-, and intra-fraction marker matching across 39 fractions. The set-up margin was determined by dividing the four periods into 39 fractions using Stroom's formula and correlation coefficient. The intra-fraction set-up error was biased in the anterior-superior (AS) direction during treatment. The temporal trend of set-up errors during radiotherapy slightly increased based on bone matching and inter-fraction marker matching, with a 1.6-mm difference in the set-up margin fractions 11 to 20. The correlation coefficient of the mean prostate movement during treatment significantly decreased in the superior-inferior direction, while remaining high in the left-right and anterior-posterior directions. Image matching contributed significantly to the improvement of set-up errors; however, careful attention is needed for prostate movement in the AS direction, particularly during short treatment times. Understanding the trend of set-up errors during the treatment period is essential in numerical information sharing on patient condition and evaluating the margins for tailored hypo-fractionated radiotherapy, considering the facility's image-guided radiation therapy technology.

5.
Phys Eng Sci Med ; 47(2): 589-596, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38372942

ABSTRACT

To investigate the impact of sagging correction calibration errors in radiotherapy software on image matching. Three software applications were used, with and without a polymethyl methacrylate rod supporting the ball bearings (BB). The calibration error for sagging correction across nine flex maps (FMs) was determined by shifting the BB positions along the Left-Right (LR), Gun-Target (GT), and Up-Down (UD) directions from the reference point. Lucy and pelvic phantom cone-beam computed tomography (CBCT) images underwent auto-matching after modifying each FM. Image deformation was assessed in orthogonal CBCT planes, and the correlations among BB shift magnitude, deformation vector value, and differences in auto-matching were analyzed. The average difference in analysis results among the three softwares for the Winston-Lutz test was within 0.1 mm. The determination coefficients (R2) between the BB shift amount and Lucy phantom matching error in each FM were 0.99, 0.99, and 1.00 in the LR-, GT-, and UD-directions, respectively. The pelvis phantom demonstrated no cross-correlation in the GT direction during auto-matching error evaluation using each FM. The correlation coefficient (r) between the BB shift and the deformation vector value was 0.95 on average for all image planes. Slight differences were observed among software in the evaluation of the Winston-Lutz test. The sagging correction calibration error in the radiotherapy imaging system was caused by an auto-matching error of the phantom and deformation of CBCT images.


Subject(s)
Cone-Beam Computed Tomography , Image Processing, Computer-Assisted , Phantoms, Imaging , Software , Calibration , Humans , Pelvis/diagnostic imaging
6.
Diagnostics (Basel) ; 13(24)2023 Dec 07.
Article in English | MEDLINE | ID: mdl-38132203

ABSTRACT

We evaluated the usefulness of simple diffusion kurtosis (SD) imaging, which was developed to generate diffusion kurtosis images simultaneously with an apparent diffusion coefficient (ADC) map for 27 cystic disease lesions in the head and neck region. The mean kurtosis (MK) and ADC values were calculated for the cystic space. The MK values were dentigerous cyst (DC): 0.74, odontogenic keratocyst (OKC): 0.86, ranula (R): 0.13, and mucous cyst (M): 0, and the ADC values were DC: 1364 × 10-6 mm2/s, OKC: 925 × 10-6 mm2/s, R: 2718 × 10-6 mm2/s, and M: 2686 × 10-6 mm2/s. The MK values of DC and OKC were significantly higher than those of R and M, whereas their ADC values were significantly lower. One reason for the characteristic signal values in diffusion-weighted images of DC may be related to content components such as fibrous tissue and exudate cells. When imaging cystic disease in the head and neck region using SD imaging, the maximum b-value setting at the time of imaging should be limited to approximately 1200 s/mm2 for accurate MK value calculation. This study is the first to show that the MK values of DC are characteristically higher than those of other cysts.

7.
Exp Ther Med ; 26(5): 536, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37869640

ABSTRACT

Increased heart dose during postoperative radiotherapy (RT) for left-sided breast cancer (BC) can cause cardiac injury, which can decrease patient survival. The deep inspiration breath-hold technique (DIBH) is becoming increasingly common for reducing the mean heart dose (MHD) in patients with left-sided BC. However, treatment planning and DIBH for RT are laborious, time-consuming and costly for patients and RT staff. In addition, the proportion of patients with left BC with low MHD is considerably higher among Asian women, mainly due to their smaller breast volume compared with that in Western countries. The present study aimed to determine the optimal machine learning (ML) model for predicting the MHD after RT to pre-select patients with low MHD who will not require DIBH prior to RT planning. In total, 562 patients with BC who received postoperative RT were randomly divided into the trainval (n=449) and external (n=113) test datasets for ML using Python (version 3.8). Imbalanced data were corrected using synthetic minority oversampling with Gaussian noise. Specifically, right-left, tumor site, chest wall thickness, irradiation method, body mass index and separation were the six explanatory variables used for ML, with four supervised ML algorithms used. Using the optimal value of hyperparameter tuning with root mean squared error (RMSE) as an indicator for the internal test data, the model yielding the best F2 score evaluation was selected for final validation using the external test data. The predictive ability of MHD for true MHD after RT was the highest among all algorithms for the deep neural network, with a RMSE of 77.4, F2 score of 0.80 and area under the curve-receiver operating characteristic of 0.88, for a cut-off value of 300 cGy. The present study suggested that ML can be used to pre-select female Asian patients with low MHD who do not require DIBH for the postoperative RT of BC.

8.
Curr Oncol ; 30(8): 7412-7424, 2023 08 04.
Article in English | MEDLINE | ID: mdl-37623018

ABSTRACT

Deep inspiration breath-hold (DIBH) is an excellent technique to reduce the incidental radiation received by the heart during radiotherapy in patients with breast cancer. However, DIBH is costly and time-consuming for patients and radiotherapy staff. In Asian countries, the use of DIBH is restricted due to the limited number of patients with a high mean heart dose (MHD) and the shortage of radiotherapy personnel and equipment compared to that in the USA. This study aimed to develop, evaluate, and compare the performance of ten machine learning algorithms for predicting MHD using a patient's body mass index and single-slice CT parameters to identify patients who may not require DIBH. Machine learning models were built and tested using a dataset containing 207 patients with left-sided breast cancer who were treated with field-in-field radiotherapy with free breathing. The average MHD was 251 cGy. Stratified repeated four-fold cross-validation was used to build models using 165 training data. The models were compared internally using their average performance metrics: F2 score, AUC, recall, accuracy, Cohen's kappa, and Matthews correlation coefficient. The final performance evaluation for each model was further externally analyzed using 42 unseen test data. The performance of each model was evaluated as a binary classifier by setting the cut-off value of MHD ≥ 300 cGy. The deep neural network (DNN) achieved the highest F2 score (78.9%). Most models successfully classified all patients with high MHD as true positive. This study indicates that the ten models, especially the DNN, might have the potential to identify patients who may not require DIBH.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Female , Unilateral Breast Neoplasms/diagnostic imaging , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Body Mass Index , Machine Learning , Tomography, X-Ray Computed
9.
Article in Japanese | MEDLINE | ID: mdl-37468252
10.
Acta Med Okayama ; 77(3): 273-280, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37357628

ABSTRACT

Diffusion kurtosis (DK) imaging (DKI), a type of restricted diffusion-weighted imaging, has been reported to be useful for tumor diagnoses in clinical studies. We developed a software program to simultaneously create DK images with apparent diffusion coefficient (ADC) maps and conducted an initial clinical study. Multi-shot echo-planar diffusion-weighted images were obtained at b-values of 0, 400, and 800 sec/mm2 for simple DKI, and DK images were created simultaneously with the ADC map. The usefulness of the DK image and ADC map was evaluated using a pixel analysis of all pixels and a median analysis of the pixels of each case. Tumor and normal tissues differed significantly in both pixel and median analyses. In the pixel analysis, the area under the curve was 0.64 for the mean kurtosis (MK) value and 0.77 for the ADC value. In the median analysis, the MK value was 0.74, and the ADC value was 0.75. The MK and ADC values correlated moderately in the pixel analysis and strongly in the median analysis. Our simple DKI system created DK images simultaneously with ADC maps, and the obtained MK and ADC values were useful for differentiating head and neck tumors from normal tissue.


Subject(s)
Diffusion Tensor Imaging , Head and Neck Neoplasms , Humans , Diffusion Magnetic Resonance Imaging/methods , Head and Neck Neoplasms/diagnostic imaging , Sensitivity and Specificity
11.
Open Vet J ; 13(4): 427-432, 2023 04.
Article in English | MEDLINE | ID: mdl-37251269

ABSTRACT

Background: Accurate dose assessment during animal radiotherapy is beneficial for veterinary medicine and medical education. Aim: To visualize the radiation treatment distribution of orthovoltage X-ray equipment in clinical practice using Monte Carlo simulations and create a dog skull water phantom for animal-specific radiotherapy. Methods: EGSnrc-based BEAMnrc and DOSXYZnrc codes were used to simulate orthovoltage dose distributions. At 10, 20, 30, 40, 50, and 80 mm in a water phantom, the depth dose was measured with waterproof Farmer dosimetry chambers, and the diagonal off-axis ratio was measured with Gafchromic EBT3 film to simulate orthovoltage dose distributions. Energy differences between orthovoltage and linear accelerated radiotherapy were assessed with a heterogeneous bone and tissue virtual phantom. The animal-specific phantom for radiotherapy quality assurance (QA) was created from CT scans of a dog and printed with a three-dimensional printer using polyamide 12 nylon, with insertion points for dosimetry chambers and Gafchromic EBT3 film. Results: Monte Carlo simulated and measured dose distributions differed by no more than 2.0% along the central axis up to a depth of 80 mm. The anode heel effect occurred in shallow areas. The orthovoltage radiotherapy percentage depth dose in bone was >40%. Build-up was >40%, with build-down after bone exit, whereas linear accelerator radiotherapy absorption changed little in the bone. A highly water-impermeable, animal-specific dog skull water phantom could be created to evaluate dose distribution. Conclusion: Animal-specific water phantoms and Monte Carlo simulated pre-treatment radiotherapy are useful QA for orthovoltage radiotherapy and yield a visually familiar phantom that will be useful for veterinary medical education.


Subject(s)
Radiometry , Water , Dogs , Animals , X-Rays , Radiometry/veterinary , Radiometry/methods , Skull , Printing, Three-Dimensional
12.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(5): 462-468, 2023 May 20.
Article in Japanese | MEDLINE | ID: mdl-36889732

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the effects of phantom factor on the verification of measured doses using cheese phantoms in tomotherapy. METHODS: Two plans for dose verification (plan classes and plan class phantom sets with a virtual organ at the risk set) were evaluated. The calculated and measured doses were compared with and without the phantom factor using cheese phantoms. Additionally, the phantom factor was evaluated for two conditions (TomoHelical/TomoDirect) in clinical cases (breast and prostate). RESULTS: When applying a phantom factor of 1.007, the deviation between the calculated and measured doses increased in Plan-Class and TomoDirect, decreased in TomoHelical, and increased in both clinical cases. CONCLUSION: When conducting dose verification, the effects of one phantom factor on measurement conditions may differ depending on when phantom factors were obtained (irradiation technique and irradiation field). It is therefore necessary to consider changes in measured doses due to changes in phantom scattering.


Subject(s)
Radiotherapy, Intensity-Modulated , Water , Male , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Phantoms, Imaging , Radiometry/methods
13.
Phys Eng Sci Med ; 46(2): 623-632, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36940063

ABSTRACT

It is important to plan radiotherapy treatment and establish optimal dose distribution to reduce the chances of side effects and injury. Because there are no commercially available tools for calculating dose distribution in orthovoltage radiotherapy in companion animals, we developed an algorithm to accomplish this and verified its characteristics using tumor disease cases. First, we used the Monte Carlo method to develop an algorithm to calculate the dose distribution of orthovoltage radiotherapy (280 kVp; MBR-320, Hitachi Medical Corporation, Tokyo, Japan) using BEAMnrc at our clinic. Using development of Monte Carlo method, dose distribution for tumor and normal organs were evaluated in brain tumors, squamous cell carcinomas of the head, and feline nasal lymphomas. In all cases of brain tumors, the mean dose delivered to the GTV ranged from 36.2 to 76.1% of the prescribed dose due to the decrease through the skull. In the nasal lymphoma in cats, the eyes with covered a 2 mm-thick lead plate, the respective average dose to the eyes was 71.8% and 89.9% less than that to the uncovered eyes. The findings may be useful for informed decision making in orthovoltage radiotherapy with more effective and targeted irradiation and data collection allowing detailed informed consent.


Subject(s)
Brain Neoplasms , Radiotherapy Planning, Computer-Assisted , Animals , Cats , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Monte Carlo Method , Algorithms
14.
Exp Ther Med ; 25(3): 109, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36793326

ABSTRACT

Magnetic resonance imaging (MRI) is superior to computed tomography (CT) in determining changes in tissue structure, such as those observed following inflammation and infection. However, when metal implants or other metal objects are present, MRI exhibits more distortion and artifacts compared with CT, which hinders the accurate measurement of the implants. A limited number of reports have examined whether the novel MRI sequence, multiacquisition variable-resonance image combination selective (MAVRIC SL), can accurately measure metal implants without distortion. Therefore, the present study aimed to demonstrate whether MAVRIC SL could accurately measure metal implants without distortion and whether the area around the metal implants could be well delineated without artifacts. An agar phantom containing a titanium alloy lumbar implant was used for the present study and was imaged using a 3.0 T MRI machine. A total of three imaging sequences, namely MAVRIC SL, CUBE and magnetic image compilation (MAGiC), were applied and the results were compared. Distortion was evaluated by measuring the screw diameter and distance between the screws multiple times in the phase and frequency directions by two different investigators. The artifact region around the implant was examined using a quantitative method following standardization of the phantom signal values. It was revealed that MAVRIC SL was a superior sequence compared with CUBE and MAGiC, as there was significantly less distortion, a lack of bias between the two different investigators and significantly reduced artifact regions. These results suggested the possibility of utilizing MAVRIC SL for follow-up to observe metal implant insertions.

16.
Phys Imaging Radiat Oncol ; 25: 100405, 2023 Jan.
Article in English | MEDLINE | ID: mdl-36655212

ABSTRACT

Background and purpose: In real-time lung tumor-tracking stereotactic body radiotherapy (SBRT), tracking accuracy is related to radiotherapy efficacy. This study aimed to evaluate the respiratory movement relationship between a lung tumor and a fiducial marker position in each direction using four-dimensional (4D) computed tomography (CT) images. Materials and methods: A series of 31 patients with a fiducial marker for lung SBRT was retrospectively analyzed using 4DCT. In the upper (UG) and middle and lower lobe groups (MLG), the cross-correlation coefficients of respiratory movement between the lung tumor and fiducial marker position in four directions (anterior-posterior, left-right, superior-inferior [SI], and three-dimensional [3D]) were calculated for each gating window (≤1, ≤2, and ≤ 3 mm). Subsequently, the proportions of phase numbers in unplanned irradiation (with lung tumors outside the gating window and fiducial markers inside the gating window) were calculated for each gating window. Results: In the SI and 3D directions, the cross-correlation coefficients were significantly different between UG (mean r = 0.59, 0.63, respectively) and MLG (mean r = 0.95, 0.97, respectively). In both the groups, the proportions of phase numbers in unplanned irradiation were 11 %, 28 %, and 63 % for the ≤ 1-, ≤2-, and ≤ 3-mm gating windows, respectively. Conclusions: Compared with MLG, fiducial markers for UG have low cross-correlation coefficients between the lung tumor and the fiducial marker position. Using 4DCT to assess the risk of unplanned irradiation in a gating window setting and selecting a high cross-correlation coefficient fiducial marker in advance are important for accurate treatment using lung SBRT.

17.
Phys Imaging Radiat Oncol ; 24: 82-87, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36267878

ABSTRACT

Background and purpose: The low tracking accuracy of lung stereotactic body radiotherapy (SBRT) risks reduced treatment efficacy. We used four-dimensional computed tomography (4DCT) images to determine the correlation between changes in fiducial marker positions and lung volume for lung tumors, and we evaluated the effectiveness of the combined use of these images in lung SBRT. Materials and methods: Data of 30 patients who underwent fiducial marker placement were retrospectively analyzed. We calculated the motion amplitudes of the center of gravity coordinates of the lung tumor and fiducial markers in each phase and the ipsilateral, contralateral, and bilateral lung volumes using 4DCT. Moreover, we calculated the cross-correlation coefficient between the fiducial marker position and the lung volume changes waveform for the motion amplitude waveform of the lung tumor over three gating windows (all phases, ≤2 mm3, and ≤3 mm3). Results: Compared with the lung volume, approximately 30 % of the fiducial markers demonstrated a low correlation with the lung tumor. In the ≤2 mm3 and ≤3 mm3 gating windows, the cross-correlation coefficients between the lung tumor and the optimal marker (r > 0.9: 83 % and 86 %) were significantly different for all fiducial markers (r > 0.9: 39 %, 53 %) and the ipsilateral (r > 0.9: 35 % and 40 %), contralateral (r > 0.9: 44 % and 41 %), and bilateral (r > 0.9: 39 % and 45 %) lung volumes. Conclusions: Some of the fiducial markers showed a low correlation with the lung tumor. This study indicated that the combined use of lung volume monitoring can improve tracking accuracy.

19.
Open Vet J ; 12(3): 407-413, 2022.
Article in English | MEDLINE | ID: mdl-35821783

ABSTRACT

Background: For optimal treatment, it is important to maintain optimal multi-leaf collimator (MLC) transmission in intensity-modulated radiation therapy (IMRT). However, adjustment of transmissions has not been reported in veterinary medicine. Aim: To demonstrate that appropriate MLC parameter adjustment for IMRT using 4- and 6-MV energy can reduce the need for quality assurance revalidation in real companion animal clinical cases. Methods: The MLC parameters (leaf transmission and leaf offset) of the treatment planning system were adjusted by evaluating seven plans (10 × 10 cm, 3ABUT, DMLC, 7segA, FOURL, HDMLC, and HIMRT) and 20 preclinical cases (10 cases each in 4- and 6-MV groups). Subsequently, 101 IMRT plans of 88 cases (77 dogs and 11 cats) were evaluated for absolute dose of plan target volume (PTV) and organs at risk (OAR) and were analyzed for the relative dose distribution by gamma analysis (3%/3 mm, >10%) using EBT3 film. Results: After adjustment of the MLC parameters (leaf transmission and leaf offset, 4 MV: 0.008 and 0, 6 MV: 0.005 and 0, respectively), the data from 101 plans (4 MV: 64 plans and 6 MV: 37 plans) treated with IMRT showed PTV <3%, OAR <5%, and gamma analysis pass rates ≥95% in all cases. Conclusion: Clinically meaningful dose distributions can be created even with a limited validation device if the treatment parameters are adjusted appropriately, even for tumors in canines and felines, where the irradiation field is small, the target is adjacent to the OAR, and the target is often superficial.


Subject(s)
Cat Diseases , Dog Diseases , Radiotherapy, Intensity-Modulated , Animals , Cats , Dog Diseases/radiotherapy , Dogs , Radiotherapy Dosage/veterinary , Radiotherapy Planning, Computer-Assisted/veterinary , Radiotherapy, Intensity-Modulated/veterinary
20.
Med Dosim ; 47(4): 329-333, 2022.
Article in English | MEDLINE | ID: mdl-35850758

ABSTRACT

Patient-specific quality assurance (QA) data must be migrated from outdated QA systems to new ones to produce objective results that can be understood by oncologists. We aimed to evaluate a method for obtaining a high correlation of dose distributions according to various gamma passing rates among two types of 2D detectors for the migration of patient-specific QA data of volumetric modulated arc therapy (VMAT). The patient-specific QA of 20 patients undergoing VMAT was measured in two different modes: standard single measurement (SM) mode and multiple merged measurements (MM) techniques using ArcCHECK (AC) and OCTAVIUS (OT). The correlation of the measured and calculated dose distributions was evaluated according to varying gamma passing rates (3%/3 mm, 2%/3 mm, 2%/2 mm, and 1%/1 mm). The gamma passing rates were analyzed using the Anderson-Darling normality test. Treatment plan dose distributions were calculated by intentionally shifting the calculation isocenter position (x,y,z ± 0.5, ± 1.0, ± 1.5, and ± 2.0 mm). The highest correlation between the SM and MM was observed with a gamma passing rate of 1%/1 mm with AC (r = 0.866) and 3%/2 mm with OT (r = 0.916). However, SM and MM did not follow a normal distribution with a rate of 3%/2 mm in OT. The second-highest correlation was obtained with a rate of 2%/2 mm (r = 0.900). Among the two 2D detectors, the highest correlation between the calculated and measured dose distributions was obtained for a gamma passing rate of 1%/1 mm using SM in AC and 2%/2 mm using MM in OT (r = 0.716). Adjusting the gamma passing rate and measurement mode of AC and OT resulted in higher correlations between measured and calculated dose distributions. The high correlation between different 2D detectors objectively indicated a potential migration method. This enabled the sharing of more accurate patient-specific QA data from 2D detectors with different phantoms. A high correlation was observed between the two types of detectors in this study (r = 0.716); therefore, the proposed method should be useful for oncologists to share information regarding patient-specific QA for VMAT.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiometry/methods , Quality Assurance, Health Care , Radiotherapy, Intensity-Modulated/methods , Phantoms, Imaging , Radiotherapy Dosage