Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 263
Filter
1.
J Clin Med ; 13(15)2024 Aug 01.
Article in English | MEDLINE | ID: mdl-39124777

ABSTRACT

(1) Background: In glaucoma patients, it is observed that intraocular pressure (IOP) in non-surgical eyes decreases during hospitalization, but detailed data have not been reported. This study aimed to examine changes in IOP in the non-surgical eyes of patients admitted for glaucoma surgery. (2) Methods: This retrospective study included 487 patients (254 males, 233 females). Statistical analysis was performed separately for groups that were and were not under medication treatment. (3) Results: In non-surgical eyes, the difference in IOP between admission and discharge was -1.6 ± 4.8 mmHg (95% confidence interval (CI), -2.1 to -1.2; p < 0.0001) with a significant decrease in the medication group (n = 414), while it was -0.6 ± 4.8 mmHg with no significant change observed (95% confidence interval (CI), -1.7 to 0.57; p = 0.33) in the non-medication group (n = 73). Multiple regression analysis of the medication group showed that IOP at admission (p < 0.0001) and older age (p = 0.03) were associated with the reduction or the rate of reduction in IOP. (4) Conclusions: IOP in the non-surgical eyes of patients admitted for glaucoma surgery with medication decreased during hospitalization. The reduction was more pronounced in individuals with higher IOP at admission and in older patients. It is possible that improved medication adherence contributes to the lowering of IOP.

2.
Bioengineering (Basel) ; 11(7)2024 Jun 29.
Article in English | MEDLINE | ID: mdl-39061751

ABSTRACT

To evaluate the effectiveness of the PRESERFLO MicroShunt (PFM) in reducing intraocular pressure (IOP) ex vivo in porcine eyes using an infusion pump system and to simulate various IOP conditions, In this study, porcine eyes received increasing flows between 2 and 20 µL/min. IOP measurements were taken under conditions with and without the PFM [PFM (+) and PFM (-), respectively]. In the PFM (-) group, IOP increased from 7.4 mmHg to 46.3 mmHg as the flow rate increased from 2 µL/min to 20 µL/min. The rate of IOP reduction (%ΔIOP) rose with increasing flow rates, although the absolute IOP values achieved with the PFM insertion also increased. The correlation between IOPs in the PFM (-) conditions and the %ΔIOP was modeled as %ΔIOP = 22.4 Ln [PFM(-) IOP] - 41.7. According to this equation, IOP reduction by PFM insertion is 0% at IOPs of 6.4 mmHg or lower. IOP reductions of 10%, 20%, 30%, and 40% were observed when the pre-insertion IOPs were 10.1, 15.7, 24.6, and 38.4 mmHg, respectively. Achievable post-insertion IOP levels of ≤21 mmHg, ≤18 mmHg, ≤15 mmHg, and ≤12 mmHg corresponded to the initial IOPs of 33 mmHg, 26 mmHg, 20 mmHg, and 14.8 mmHg, respectively. In conclusion, the PFM effectively reduced IOP within a specific range of IOP values in an ex vivo experimental system. In clinical situations, the PFM is unlikely to be effective at low IOP levels. At higher levels, the PFM reduces IOP, but it may be insufficient to achieve the target IOP.

3.
Curr Issues Mol Biol ; 46(7): 6940-6950, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-39057055

ABSTRACT

Carotenoids, having strong antioxidant properties, have been associated with neurodegenerative conditions like dementia and glaucoma, characterized by neuronal loss leading to cognitive and visual dysfunction. Therefore, carotenoids have attracted attention as factors predictive of the onset and progression of these neurodegenerative diseases. However, the impact of carotenoids on cognitive impairment and glaucomatous visual field defects remains unexplored. We conducted a retrospective, observational clinical study to investigate the association between skin carotenoid (SC) levels and cognitive impairment, as screened by the Mini-Cog test, in glaucoma patients. The study included 406 participants and 812 eyes were examined (average age: 69.7 ± 11.4 years; 228 men, 178 women) with various types of glaucoma: primary open angle (57.6%), exfoliation (18.6%), and other types (23.8%). SC levels were estimated via pressure-mediated reflection spectroscopy. Mixed-effects regression models were utilized to examine the relationship between SC levels, visual field defects, and Mini-Cog results. Of the participants, 28 (6.9%) tested positive on the Mini-Cog, suggesting cognitive impairment. The average SC level in the Mini-Cog positive group was significantly lower than in the negative group (269.5 ± 86.4 A.U. vs. 329.2 ± 120.4 A.U., respectively; p = 0.01). Additionally, the visual field mean deviation (MD) in the Mini-Cog positive group was notably worse than that in the negative group (-19.64 ± 9.07 dB vs. -12.46 ± 9.28 dB, respectively; p < 0.0001). The mixed-effects regression analysis revealed a significant association between Mini-Cog positivity and lower SC levels (p = 0.0006), although SC levels did not significantly correlate with MD (p = 0.3). Our findings suggest that cognitive impairment in glaucoma patients is associated with lower SC levels, underscoring the potential benefits of maintaining carotenoid levels to slow cognitive function decline. The protective role of carotenoids in glaucoma merits further investigation.

4.
BMJ Open Ophthalmol ; 9(1)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38960415

ABSTRACT

BACKGROUND: To investigate if there are improvements in trabeculectomy outcomes supporting filtration bleb formation caused by Rho-associated protein kinase (ROCK) inhibitors. METHODS: This prospective, multicentre, randomised, open-label clinical study examined open-angle glaucoma patients who underwent trabeculectomy or trabeculectomy combined with cataract surgery followed by 3-month postoperative ripasudil treatments. After randomly allocating patients to ripasudil-ROCK inhibitor (ripasudil) or without ripasudil (non-ripasudil) groups. Mean intraocular pressure (IOP) changes, success rate, and number of eyedrops were compared for both groups. RESULTS: A total of 17 and 15 subjects dropped out in the ripasudil group and non-ripasudil group, respectively. At baseline, the mean IOP was 16.8±5.0 mm Hg in the ripasudil group (38 patients) and 16.2±4.4 in the non-ripasudil group (52 patients). The IOP decreased to 11.4±3.2 mm Hg, 10.9±3.9 mm Hg and 10.6±3.5 mm Hg at 12, 24 and 36 months in the ripasudil group, while it decreased to 11.2±4.1 mm Hg, 10.5±3.1 mm Hg and 10.9±3.2 mm Hg at 12, 24 and 36 months in the non-ripasudil group, respectively. There was a significant decrease in the number of IOP-lowering medications after trabeculectomy in the ripasudil group versus the non-ripasudil group at 24 (p=0.010) and 36 months (p=0.016). There was no statistically significant difference between the groups for the 3-year cumulative probability of success. CONCLUSION: Although ripasudil application did not increase the primary trabeculectomy success rate, it did reduce IOP-lowering medications after trabeculectomy with mitomycin C.


Subject(s)
Glaucoma, Open-Angle , Intraocular Pressure , Isoquinolines , Mitomycin , Sulfonamides , Trabeculectomy , Humans , Trabeculectomy/methods , Male , Intraocular Pressure/drug effects , Prospective Studies , Female , Glaucoma, Open-Angle/surgery , Glaucoma, Open-Angle/drug therapy , Isoquinolines/therapeutic use , Isoquinolines/administration & dosage , Aged , Sulfonamides/therapeutic use , Sulfonamides/administration & dosage , Mitomycin/therapeutic use , Mitomycin/administration & dosage , Middle Aged , rho-Associated Kinases/antagonists & inhibitors , Treatment Outcome , Alkylating Agents/administration & dosage , Alkylating Agents/therapeutic use
5.
Int Med Case Rep J ; 17: 545-553, 2024.
Article in English | MEDLINE | ID: mdl-38828363

ABSTRACT

Introduction: Although ab-interno trabeculotomy-related (goniotomy-related) surgeries has a favorable safety profile, cyclodialysis cleft refractory to conservative management could occur, thereby requiring additional surgical treatment. External and, more recently, internal cycloplexy have been attempted to treat cyclodialysis clefts with hypotony maculopathy, however the traditional methods require conjunctival or scleral incisions and have been inappropriate for glaucoma patients who need to undergo future trabeculectomy. Therefore, we report two cases who underwent a novel reliable technique for suture fixation of the detached ciliary body onto the original scleral bed directly through the intraocular approach without conjunctival or scleral incision, minimally invasive direct internal cyclopexy, in the management of goniotomy-related cyclodialysis cleft with hypotony maculopathy. Case Description: Goniotomy-related cyclodialysis cleft exceeded 45° and vision-threatening hypotony maculopathy was observed in two eyes in two patients with normal tension glaucoma and myopia gravis without a prior history of trauma who had undergone Kahook Dual Blade goniotomy combined with cataract surgery. The patients were followed conservatively for a while, however the cyclodialysis clefts and hypotony maculopathies did not resolve. Therefore, a 72-year-old man underwent minimally invasive direct internal cyclopexy on postoperative day 65 after the goniotomy, and another 67-year-old man underwent minimally invasive direct internal cyclopexy on postoperative day 149. In both cases, topical antibiotic and steroid eye drops were prescribed postoperatively. The cyclodialysis clefts were repaired successfully; however, the latter patient developed delayed-onset acute transient ocular hypertension 33 days after minimally invasive direct internal cyclopexy and required glaucoma medications. The hypotony maculopathies resolved approximately 3 months after suturing, and eventually visual acuity improved from preoperative levels and good intraocular pressure control was achieved in both. No further postoperative complications have been observed to date. Conclusion: We successfully managed two cases of goniotomy-related cyclodialysis cleft with hypotony maculopathy using minimally invasive direct internal cyclopexy.

6.
BMC Ophthalmol ; 24(1): 227, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38811878

ABSTRACT

OBJECTIVE: To present six cases exhibiting transient anterior subcapsular vacuolar lens opacities following early postoperative Tanito microhook trabeculotomy (TMH) performed by the same surgeon. METHODS: Six patients who underwent lens-sparing TMH at Meizankai Shimizu Eye Clinic from November 2021 to May 2023, and developed anterior subcapsular vacuolar lens opacities postoperatively were reviewed. Detailed records of surgeries, follow-up findings were collected and reported. RESULTS: In all six cases, anterior vacuolar subcapsular lens opacities were observed on the day after surgery, gradually decreasing without affecting visual acuity or contrast sensitivity. In all cases, without any specific interventions, the opacities disappeared by 21 months postoperatively. CONCLUSION: Anterior subcapsular cataracts, characterized by a vacuolar appearance and transient existence, should be recognized as an early complication of ab interno glaucoma surgery, possibly linked to use of distributed ophthalmic viscosurgical devices and excessive anterior chamber irrigation leading to traumatic cataracts on the lens surface.


Subject(s)
Cataract , Trabeculectomy , Visual Acuity , Adult , Aged , Female , Humans , Male , Middle Aged , Glaucoma/surgery , Intraocular Pressure/physiology , Lens Capsule, Crystalline/surgery , Lens Capsule, Crystalline/pathology , Postoperative Complications , Retrospective Studies , Trabeculectomy/adverse effects , Vacuoles/pathology
7.
Cureus ; 16(4): e58356, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38756279

ABSTRACT

We experienced a case of bilateral corneal thinning during the oral taking of S-1, a combination anti-cancer drug of tegafur, gimeracil, and oteracil-potassium. A 69-year-old man was prescribed oral S-1 for the treatment of duodenal papilla adenocarcinoma and intraductal papillary mucinous neoplasm. However, he developed a decrease in visual acuity in both eyes after three cycles of S-1 oral taking, and ophthalmic examination revealed corneal thinning exceeding 100 µm and an increase in high-order irregularity of cornea in both eyes. After one month after discontinuation of S-1, his visual acuity and corneal thickness returned to its previous levels. Besides corneal ulcers and perforations, corneal thinning can be recognized as a potential corneal side effect necessitating monitoring during S-1 treatment.

8.
Redox Biol ; 73: 103186, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38744193

ABSTRACT

Recent studies have highlighted the indispensable role of oxidized lipids in inflammatory responses, cell death, and disease pathogenesis. Consequently, inhibitors targeting oxidized lipids, particularly lipid-derived radicals critical in lipid peroxidation, which are known as radical-trapping antioxidants (RTAs), have been actively pursued. We focused our investigation on nitroxide compounds that have rapid second-order reaction rate constants for reaction with lipid-derived radicals. A novel screening system was developed by employing competitive reactions between library compounds and a newly developed profluorescence nitroxide probe with lipid-derived radicals to identify RTA compounds. A PubMed search of the top hit compounds revealed their wide application as repositioned drugs. Notably, the inhibitory efficacy of methyldopa, selected from these compounds, against retinal damage and bilateral common carotid artery stenosis was confirmed in animal models. These findings underscore the efficacy of our screening system and suggest that it is an effective approach for the discovery of RTA compounds.


Subject(s)
Antioxidants , Lipid Peroxidation , Animals , Humans , Antioxidants/pharmacology , Antioxidants/chemistry , Lipid Peroxidation/drug effects , Retinal Diseases/drug therapy , Retinal Diseases/metabolism , Cerebrovascular Disorders/drug therapy , Cerebrovascular Disorders/metabolism , Free Radicals/metabolism , Disease Models, Animal , Drug Evaluation, Preclinical , Mice , Lipids/chemistry
9.
BMJ Open Ophthalmol ; 9(1)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38626932

ABSTRACT

BACKGROUND/AIMS: This study aimed to investigate and compare the efficacy and safety of first-line and second-line selective laser trabeculoplasty (SLT) in Japanese patients with normal-tension glaucoma (NTG). METHODS: 100 patients with NTG were enrolled in this study. Patients were treated with SLT as a first-line or second-line treatment for NTG. Main outcome measures were intraocular pressure (IOP) reduction rate, outflow pressure improvement rate (ΔOP), success rate at 1 year and complications. Success was defined as ΔOP≥20% (criterion A) or an IOP reduction ≥20% (criterion B) without additional IOP-lowering eye-drops, repeat SLT or additional glaucoma surgeries. The incidence of transient IOP spike (>5 mm Hg from the pretreatment IOP), conjunctival hyperaemia, inflammation in the anterior chamber and visual impairment due to SLT were assessed. RESULTS: A total of 99 patients (99 eyes) were initially enrolled in this study, including 74 eyes assigned to the first-line SLT group and 25 eyes to the second-line SLT group. The mean IOP of 16.3±2.1 mm Hg before SLT decreased by 17.1%±9.5% to 13.4±1.9 mm Hg at 12 months after SLT in the first-line group (p<0.001), and the mean IOP of 15.4±1.5 mm Hg before SLT decreased by 12.7%±9.7% to 13.2±2.0 mm Hg at 12 months after SLT (p=0.005) in the second-line group. Both groups showed significant reductions in IOP. Higher pre-SLT IOP and thinner central corneal thickness were associated with greater IOP reduction. The success rate at 1 year was higher in the first-line compared with the second-line group, with lower pretreatment IOP and the use of IOP-lowering medication before SLT being associated with treatment failure. Most post-treatment complications were minor and transient. CONCLUSIONS: SLT may be an effective and safe treatment option for NTG, as either a first-line or second-line treatment. TRIAL REGISTRATION NUMBER: The study was registered in the UMIN-CTR (UMIN Test ID: UMIN R000044059).


Subject(s)
Glaucoma , Lasers, Solid-State , Low Tension Glaucoma , Ocular Hypotension , Trabeculectomy , Humans , Trabeculectomy/adverse effects , Intraocular Pressure , Low Tension Glaucoma/surgery , Glaucoma/surgery , Ocular Hypotension/surgery , Anterior Chamber , Lasers, Solid-State/therapeutic use , Cohort Studies
10.
Am J Ophthalmol Case Rep ; 33: 102008, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38374947

ABSTRACT

Purpose: This study aims to present two different types of giant bleb formation following Ahmed Glaucoma Valve (AGV) implantation: an anterior enlarged giant bleb and a posterior enlarged giant bleb. Observations: In Case 1, a 70-year-old Japanese male underwent AGV implantation for neovascular glaucoma in his right eye (OD). Preoperatively, the patient's intraocular pressure (IOP) and best corrected visual acuity (BCVA) were 23 mmHg and 0.6, respectively, OD, while using 3 antiglaucoma topical medications. Two months post-surgery, the patient began experiencing double vision. Slit lamp evaluation revealed no abnormalities, IOP and BCVA were 24.0 mmHg and 0.8, respectively, OD. A posteriorly enlarged bleb in the superotemporal quadrant OD was found to be causing displacement on T2-weighted orbital MRI. The patient underwent surgical excision of the anterior bleb wall. By three weeks post-surgery, the double vision resolved; IOP and BCVA were 17 mmHg and 0.7, respectively, and a normal bleb in the slit lamp evaluation was identified OD. In Case 2, a 10-year-old Japanese female underwent AGV implantation for childhood glaucoma associated with congenital cataract OD. Preoperatively, IOP and BCVA were 30 mmHg and 0.5, respectively, OD, while using 3 antiglaucoma topical medications. She underwent pars plana vitrectomy (PPV) in addition to AGV implantation. Seven months post-surgery, slip lamp evaluation revealed an anteriorly enlarged giant bleb that only cause her a cosmetic concern. Conclusions and Importance: There are two types of giant bleb formation following AGV implantation based on the direction of the enlargement: an anterior enlarged giant bleb and a posterior enlarged giant bleb. The introduction of this classification contribute to better understanding and management of this unusual surgical complication.

11.
Invest Ophthalmol Vis Sci ; 65(2): 15, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38324302

ABSTRACT

Purpose: This study aimed to histologically compare the status of Schlemm's canal (SC) and Schlemm's canal endothelial (SCE) cells between trabeculectomy specimens from patients with primary open-angle glaucoma (POAG) and exfoliation glaucoma (EXG). Methods: A total of 182 eyes from 152 patients with POAG and 138 eyes from 116 patients with EXG underwent immunohistochemical staining for thrombomodulin. Equal numbers of cases were selected from both groups using propensity score matching. The following parameters were evaluated: total SC length, staining positive and negative SC length (PSC and NSC, respectively), opened and closed SC length, staining positive and opened SC length, staining positive and closed SC length, staining negative and opened SC length (NOSC), and staining negative and closed SC length. Results: After matching for age and gender, 87 cases were selected in each group. The EXG group had significantly higher preoperative IOP and medication scores. PSC was significantly longer in the POAG group, while NSC and NOSC were longer in the EXG group. Multiple regression analysis of these 174 cases revealed that PSC was significantly shorter in the EXG group. After matching for age, gender, preoperative IOP, and medication score, 64 cases were selected in each group, and NOSC was significantly longer in the EXG group. Conclusions: These findings suggest that in EXG, SCE loss occurs independently of background factors such as aging and medication use. The loss of SCE may have a more critical impact on IOP elevation in EXG compared to POAG.


Subject(s)
Exfoliation Syndrome , Glaucoma, Open-Angle , Humans , Propensity Score , Schlemm's Canal , Eye
12.
Sci Rep ; 14(1): 3683, 2024 02 14.
Article in English | MEDLINE | ID: mdl-38355836

ABSTRACT

To investigate the association between lactate metabolism and glaucoma, we conducted a multi-institutional cross-sectional clinical study and a retinal metabolomic analysis of mice with elevated intraocular pressure (IOP) induced by intracameral microbead injection. We compared lactate concentrations in serum and aqueous humor in age-matched 64 patients each with primary open-angle glaucoma (POAG) and cataract. Neither serum nor aqueous humor lactate concentrations differed between the two groups. Multiple regression analysis revealed that only body mass index showed a significant positive correlation with serum and aqueous humor lactate concentration in POAG patients (rs = 0.376, P = 0.002, and rs = 0.333, P = 0.007, respectively), but not in cataract patients. L-Lactic acid was one of the most abundantly detected metabolites in mouse retinas with gas chromatography and mass spectrometry, but there were no significant differences among control, 2-week, and 4-week IOP elevation groups. After 4 weeks of elevated IOP, D-glucose and L-glutamic acid ranked as the top two for a change in raised concentration, roughly sevenfold and threefold, respectively (ANOVA, P = 0.004; Tukey-Kramer, P < 0.05). Glaucoma may disrupt the systemic and intraocular lactate metabolic homeostasis, with a compensatory rise in glucose and glutamate in the retina.


Subject(s)
Cataract , Glaucoma, Open-Angle , Animals , Humans , Mice , Aqueous Humor/metabolism , Cataract/metabolism , Cross-Sectional Studies , Gas Chromatography-Mass Spectrometry , Glaucoma, Open-Angle/metabolism , Glutamic Acid/metabolism , Homeostasis , Intraocular Pressure , Lactic Acid/metabolism , Retina/metabolism
13.
J Clin Med ; 12(23)2023 Nov 23.
Article in English | MEDLINE | ID: mdl-38068318

ABSTRACT

This study aims to investigate the pressure characteristics of the PRESERFLO MicroShunt, a microinvasive glaucoma device, using an in vitro setup. Additionally, the study explores the impact of the scleral tissue surrounding the device on its pressure and lumen area. Ten PRESERFLO MicroShunts were subjected to an in vitro experimental setup. A constant flow of physiological saline was maintained at 2 µL/min using an infusion syringe pump. The PRESERFLO was connected to a pressure transducer via a 23 G needle. Pressure characteristics were measured under three different conditions: without sclera [sclera (-)], passing through sclera at a 90° angle (sclera 90°), and passing through sclera at a 30° angle (sclera 30°). The lumen area of the device was measured using microscopic observation. We observed peak and trough pressures in this experimental setting; the peak pressure (6.76 mmHg) was significantly higher than the trough pressure of 4.74 mmHg (p = 0.0020) in the sclera (-) condition. Compared to sclera (-), the peak pressures were significantly higher in the sclera 90° (7.81 mmHg, p = 0.0020) and the sclera 30° (7.96 mmHg, p = 0.0039) conditions. Additionally, compared to sclera (-), the trough pressure was significantly higher in the sclera 90° (6.25 mmHg, p = 0.0039) and the sclera 30° (5.76 mmHg, p = 0.037) conditions. The lumen area was significantly smaller in the sclera 90° condition (3515 µm2) than the sclera (-) condition (3927 µm2, p = 0.0078). The study found that when the distal end of PRESERFLO MicroShunt was free and in air, it exhibited both peak and trough pressures. The presence of scleral tissue surrounding the PRESERFLO MicroShunt affects its lumen area and pressure characteristics. Understanding these effects can provide valuable insights into the device's performance.

14.
J Clin Med ; 12(23)2023 Dec 01.
Article in English | MEDLINE | ID: mdl-38068513

ABSTRACT

This study compared the effectiveness and safety of 120-degree (nasal) and 240-degree (bilateral) incisions in Tanito Microhook Trabeculotomy (TMH) combined with cataract surgery in patients with open-angle glaucoma. From a pool of 185 eyes, 67 eyes from 67 subjects were selected for each incision group using propensity score matching to align age, sex, glaucoma type, and preoperative intraocular pressure (IOP). The study found that preoperative IOP, initially 18.6 mmHg in both groups, decreased to 13.2 mmHg in the nasal group and 12.8 mmHg in the bilateral group 12 months postoperatively, representing reductions of 29% and 31%, respectively. Similarly, medication scores decreased from 3.4 to 2.7 in the nasal group and from 3.1 to 2.5 in the bilateral group. Notably, the bilateral incision group exhibited a significantly higher hyphema red blood cell score compared to the nasal group (p < 0.0001). Across the study period, other parameters such as IOP, medication score, visual acuity, anterior chamber flare, corneal endothelial cell density, visual field mean deviation, and the frequency of surgical complications other than hyphema were similar between the groups. The study concluded that TMH combined with cataract surgery is equally effective and safe regardless of incision width, although narrower incisions resulted in reduced early postoperative hyphema.

15.
J Clin Med ; 12(22)2023 Nov 09.
Article in English | MEDLINE | ID: mdl-38002619

ABSTRACT

This study aims to compare the surgical efficacy and safety of the Tanito microhook trabeculotomy (TMH-CE) and iStent inject W (Inject-CE) when performed in combination with cataract surgery on the eyes of glaucoma patients. A total of 78 glaucomatous eyes from 39 participants were retrospectively analyzed. Intraocular pressure (IOP), the number of antiglaucoma medications, best-corrected visual acuity (BCVA), anterior chamber flare (ACF), and corneal endothelial cell density (CECD) were all evaluated preoperatively and at multiple postoperative time points. The preoperative IOP was significantly higher in the TMH-CE (19.6 ± 6.7 mmHg) than in the Inject-CE (15.7 ± 3.8 mmHg) (p < 0.0001). At the 12-month follow-up, reductions in IOP and the number of medications were more pronounced in the TMH-CE (6.6 mmHg, 27.6% and -1.1, respectively) group than Inject-CE (2.7 mmHg, 12.4% and -0.7, respectively) (p < 0.0001 and p = 0.0034), while the IOP and medication-number levels were identical between TMH-CE (13.0 ± 3.3 mmHg and 1.3 ± 0.9, respectively) and Inject-CE (12.9 ± 2.6 mmHg and 1.9 ± 0.9, respectively) (p = 0.88 and p > 0.99, respectively). The TMH-CE group exhibited a higher ACF, a higher frequency of layered hyphema, and a greater anterior chamber floating red blood cells score in the early postoperative periods. Despite these differences, the changes in BCVA, ACF, and CECD were equivalent between the two groups in later follow-up periods. TMH-CE provides a more significant IOP reduction and medication-number reduction compared to Inject-CE, while Inject-CE shows quicker BCVA recovery. This study provides valuable insights for ophthalmologists choosing the most suitable surgical approach for glaucoma and cataract patients.

16.
J Clin Med ; 12(22)2023 Nov 15.
Article in English | MEDLINE | ID: mdl-38002731

ABSTRACT

This study reports the prevalence of cognitive impairment (CI) in patients attending a glaucoma outpatient clinic at a tertiary hospital. It also comprehensively assesses possible associations between CI and visual field (VF) reliability indices among glaucoma patients. The retrospective analysis included 1464 eyes from 746 subjects (mean age, 70.6 ± 11.9; 401 males and 345 females). CI was evaluated using the Mini-Cog test, revealing a suspected prevalence of 8.0% (60 out of 746) among the patients. After adjusting for various background parameters using a mixed effects regression model, an abnormal Mini-Cog score was linked to higher false negative (FN) (p = 0.0034) and false positive (FP) (p = 0.0051) but not fixation loss (FL) (p = 0.82). Among the Mini-Cog components, a lower word recall test score was associated with higher FN (p < 0.0001), with a borderline difference in FP (p = 0.054) and no significant effect on FL (p = 0.09). Conversely, a lower clock drawing test score was associated with higher FP (p = 0.038), while FL (p = 0.49) and FN (p = 0.12) remained unaffected. These findings suggest that CI can impact the reliability of VF testing among glaucoma patients, highlighting the importance of assessing cognitive function in glaucoma care.

17.
Cureus ; 15(10): e47356, 2023 Oct.
Article in English | MEDLINE | ID: mdl-38022219

ABSTRACT

We report a case of PreserFlo MicroShunt (PFM) dislocation following a postsurgical needling procedure. A 58-year-old woman underwent PFM implantation for exfoliation glaucoma in her left eye (OS). There were no intraoperative complications. Preoperatively, her best-corrected visual acuity (BCVA) was 0.6, and her intraocular pressure (IOP) was 25 mmHg with three antiglaucoma medications in the OS. On postoperative day 21, the IOP was 21 mmHg OS, and the filtration bleb had shrunk. A needling procedure was performed using a sharp 26-gauge needle to lower the IOP. On postoperative day 29, the BCVA was 0.02, and the IOP was 60 mmHg OS. Gonioscopy revealed no device tip in the anterior chamber, and peripheral anterior synechia was observed at the site of PFM insertion. Anterior segment optical coherence tomography showed a dislocated device in the subconjunctival space. On postoperative day 35, the dislocated PFM was removed, and a new device was inserted. Following the reoperation, no further complications were observed, and bleb formation was obtained. In conclusion, like other glaucoma filtering surgeries, PFM may require postsurgical needling procedures. Needling procedures may cause PFM dislocation and IOP rise, resulting in the requirement for further IOP-reducing procedures.

18.
Case Rep Ophthalmol ; 14(1): 477-483, 2023.
Article in English | MEDLINE | ID: mdl-37901638

ABSTRACT

PHACE(S) syndrome is a neurocutaneous disorder with a hallmark finding of an infantile facial hemangioma (IFH) >5 cm. Eye examination of patients with PHACE(S) syndrome with no IFH at periorbital region is reported to be of low yield. We report a unique case of the syndrome with ocular manifestations without periorbital IFH or systemic findings. A 3-week-old female infant with right periauricular IFH >5 cm, extending to the neck and cheek and lower lip IFH was presented. Examination revealed pseudoptosis due to microphthalmia with esotropia and hypertropia. Both corneas were clear with diameters of 5 mm and 10 mm, right eye (RE) and left eye (LE), respectively. There was a posterior polar cataract with a poor view of the fundus RE. Ocular B-scan and magnetic resonance imaging (MRI) findings were suggestive of a dysmorphic globe, vitreous hemorrhage, spherophakia and persistent fetal vasculature RE and normal findings LE. Clinical evaluation, MRI, and MR angiography revealed no other systemic abnormalities. Subsequent follow-up visits revealed progressive clouding of the cornea with neovascularization and the development of phthisis bulbi RE at which point an ocular prosthesis was placed. The IFH was managed with dye laser and with oral propranolol. At 1 year, the patient has remained stable with no development of new local or systemic anomalies, regression of the periauricular and lip IFH, and normal development of the orbital structure RE with an ocular prosthesis in situ. Ocular involvement in patients with PHACE(S) syndrome may be present without periorbital IFH. Regardless of the location of the IFH and the presence or absence of a periocular component, it is recommended that they receive a full initial ophthalmological assessment.

19.
Adv Ther ; 40(11): 4907-4918, 2023 11.
Article in English | MEDLINE | ID: mdl-37707675

ABSTRACT

INTRODUCTION: To report eyedrop instillation techniques and factors associated with instillation failure among glaucoma subjects in the Video-Recorded Assessment of Medication Skill and Questionnaire-based evaluation of Perception in Glaucoma Study. METHODS: In this cross-sectional observational study, subjects were 60 patients with glaucoma (mean ± standard deviation age, 68.4 ± 11.3 years; 30 men) who required ocular hypotensive medication(s). Subjects completed ophthalmologic examinations and the Mini-Cog cognitive function test; their typical eyedrop instillation technique was video-recorded. Subjects rated their technique as successes/failures by questionnaire and two examiners rated the successes/failures based on video assessment. Discrepancy between self-reported and video-assessed success/failure rates of instillation was the main outcome measures. Multivariate logistic regression identified factors in instillation failure. RESULTS: Of 48/56 (86%) self-reported successes, 27/48 (56%) failed based on video assessment; as a result, 32/56 (57%) were inconsistent between subjective and objective assessments. Overall, 30/56 (54%) failed based on video assessment. In the subject-based data model, older age [odds ratio (OR) 0.93/year, P = 0.025] and lower cognitive function score (OR 2.7/score, P = 0.025) were factors in failed instillations. In the eye-based data model, less myopic objective refractive error (OR 0.77/diopter, P = 0.016) and lower visual field foveal threshold (OR 1.1/decibel, P = 0.041) were factors in failures. CONCLUSION: In addition to older age, decreased cognitive function, hyperopia, and decreased foveal sensitivity are risks for failed eyedrop instillation. Treating physicians can screen patients who require guidance by checking the risk factors of instillation failure rather than by relying on patient reports.


Subject(s)
Glaucoma , Aged , Humans , Male , Middle Aged , Antihypertensive Agents/therapeutic use , Cross-Sectional Studies , Glaucoma/drug therapy , Intraocular Pressure , Medication Adherence , Ophthalmic Solutions/therapeutic use , Surveys and Questionnaires , Female
20.
Am J Ophthalmol ; 256: 118-125, 2023 12.
Article in English | MEDLINE | ID: mdl-37573988

ABSTRACT

PURPOSE: To compare the efficacy and safety of 120-, 240-, and 360-degree goniotomy (GT) with or without phacoemulsification with intraocular lens implantation (PEI) for patients with primary open-angle glaucoma (POAG). DESIGN: Multicenter, retrospective, comparative, nonrandomized interventional study. METHODS: Patients diagnosed with POAG who underwent GT with or without PEI were included, and divided into 6 groups: 1) standalone 120-degree GT (120GT); 2) standalone 240-degree GT (240GT); 3) standalone 360-degree GT (360GT); 4) PEI + 120GT; 5) PEI + 240GT; and 6) PEI + 360GT. Data on intraocular pressure (IOP), the number of ocular hypotensive medications, and complications were collected and compared. Success was defined as a postoperative IOP within the range of 6 to 18 mm Hg and a 20% reduction from baseline without further glaucoma surgery. Complete success and qualified success were defined as the above without and with ocular hypotensive medications, respectively. RESULTS: Three hundred eight eyes of 231 patients were included with a mean follow-up of 14.4 ± 8.6 months (6.0-48.0 months). There were no significant differences in the reductions in IOP and number of medications and cumulative survival probability for complete and qualified success rates among the 3 groups of standalone GT and PEI + GT. The 360GT group had the highest proportion of hyphema with or without PEI. CONCLUSIONS: 120GT, 240GT, and 360GT with or without PEI showed similar efficacy in reducing IOP and medications used in POAG. 360GT with or without PEI was more likely to cause hyphema compared with 120GT or 240GT. 120GT with or without PEI was sufficient for treating POAG with or without cataract..


Subject(s)
Cataract , Glaucoma, Open-Angle , Phacoemulsification , Trabeculectomy , Humans , Glaucoma, Open-Angle/drug therapy , Glaucoma, Open-Angle/surgery , Glaucoma, Open-Angle/complications , Retrospective Studies , Hyphema/complications , Hyphema/drug therapy , Hyphema/surgery , Treatment Outcome , Intraocular Pressure , Tonometry, Ocular , Cataract/complications , Antihypertensive Agents/therapeutic use
SELECTION OF CITATIONS
SEARCH DETAIL