Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 82
1.
Heart Lung Circ ; 2024 May 02.
Article En | MEDLINE | ID: mdl-38702234

Catheter ablation for atrial fibrillation (AF) has increased exponentially in many developed countries, including Australia and New Zealand. This Expert Position Statement on Catheter and Surgical Ablation for Atrial Fibrillation from the Cardiac Society of Australia and New Zealand (CSANZ) recognises healthcare factors, expertise and expenditure relevant to the Australian and New Zealand healthcare environments including considerations of potential implications for First Nations Peoples. The statement is cognisant of international advice but tailored to local conditions and populations, and is intended to be used by electrophysiologists, cardiologists and general physicians across all disciplines caring for patients with AF. They are also intended to provide guidance to healthcare facilities seeking to establish or maintain catheter ablation for AF.

2.
J Am Heart Assoc ; 13(9): e031795, 2024 May 07.
Article En | MEDLINE | ID: mdl-38664237

BACKGROUND: Transcatheter renal denervation (RDN) has had inconsistent efficacy and concerns for durability of denervation. We aimed to investigate long-term safety and efficacy of transcatheter microwave RDN in vivo in normotensive sheep in comparison to conventional radiofrequency ablation. METHODS AND RESULTS: Sheep underwent bilateral RDN, receiving 1 to 2 microwave ablations (maximum power of 80-120 W for 240 s-480 s) and 12 to 16 radiofrequency ablations (180 s-240 s) in the main renal artery in a paired fashion, alternating the side of treatment, euthanized at 2 weeks (acute N=15) or 5.5 months (chronic N=15), and compared with undenervated controls (N=4). Microwave RDN produced substantial circumferential perivascular injury compared with radiofrequency at both 2 weeks [area 239.8 (interquartile range [IQR] 152.0-343.4) mm2 versus 50.1 (IQR, 32.0-74.6) mm2, P <0.001; depth 16.4 (IQR, 13.9-18.9) mm versus 7.5 (IQR, 6.0-8.9) mm P <0.001] and 5.5 months [area 20.0 (IQR, 3.4-31.8) mm2 versus 5.0 (IQR, 1.4-7.3) mm2, P=0.025; depth 5.9 (IQR, 1.9-8.8) mm versus 3.1 (IQR, 1.2-4.1) mm, P=0.005] using mixed models. Renal denervation resulted in significant long-term reductions in viability of renal sympathetic nerves [58.9% reduction with microwave (P=0.01) and 45% reduction with radiofrequency (P=0.017)] and median cortical norepinephrine levels [71% reduction with microwave (P <0.001) and 72.9% reduction with radiofrequency (P <0.001)] at 5.5 months compared with undenervated controls. CONCLUSIONS: Transcatheter microwave RDN produces deep circumferential perivascular ablations without significant arterial injury to provide effective and durable RDN at 5.5 months compared with radiofrequency RDN.


Kidney , Microwaves , Renal Artery , Sympathectomy , Animals , Microwaves/therapeutic use , Microwaves/adverse effects , Sympathectomy/methods , Sympathectomy/adverse effects , Renal Artery/innervation , Kidney/innervation , Kidney/blood supply , Sheep , Catheter Ablation/methods , Catheter Ablation/adverse effects , Time Factors , Disease Models, Animal , Blood Pressure/physiology , Female , Radiofrequency Ablation/methods , Radiofrequency Ablation/adverse effects
3.
Heart Lung Circ ; 32(2): 184-196, 2023 Feb.
Article En | MEDLINE | ID: mdl-36599791

IMPORTANCE: Randomised trials have shown that catheter ablation (CA) is superior to medical therapy for ventricular tachycardia (VT) largely in patients with ischaemic heart disease. Whether this translates to patients with all forms and stages of structural heart disease (SHD-e.g., non-ischaemic heart disease) is unclear. This trial will help clarify whether catheter ablation offers superior outcomes compared to medical therapy for VT in all patients with SHD. OBJECTIVE: To determine in patients with SHD and spontaneous or inducible VT, if catheter ablation is more efficacious than medical therapy in control of VT during follow-up. DESIGN: Randomised controlled trial including 162 patients, with an allocation ratio of 1:1, stratified by left ventricular ejection fraction (LVEF) and geographical region of site, with a median follow-up of 18-months and a minimum follow-up of 1 year. SETTING: Multicentre study performed in centres across Australia. PARTICIPANTS: Structural heart disease patients with sustained VT or inducible VT (n=162). INTERVENTION: Early treatment, within 30 days of randomisation, with catheter ablation (intervention) or initial treatment with antiarrhythmic drugs only (control). MAIN OUTCOMES, MEASURES, AND RESULTS: Primary endpoint will be a composite of recurrent VT, VT storm (≥3 VT episodes in 24 hrs or incessant VT), or death. Secondary outcomes will include each of the individual primary endpoints, VT burden (number of VT episodes in the 6 months preceding intervention compared to the 6 months after intervention), cardiovascular hospitalisation, mortality (including all-cause mortality, cardiac death, and non-cardiac death) and LVEF (assessed by transthoracic echocardiography from baseline to 6-, 12-, 24- and 36-months post intervention). CONCLUSIONS AND RELEVANCE: The Catheter Ablation versus Anti-arrhythmic Drugs for Ventricular Tachycardia (CAAD-VT) trial will help determine whether catheter ablation is superior to antiarrhythmic drug therapy alone, in patients with SHD-related VT. TRIAL REGISTRY: Australian New Zealand Clinical Trials Registry (ANZCTR) TRIAL REGISTRATION ID: ACTRN12620000045910 TRIAL REGISTRATION URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=377617&isReview=true.


Catheter Ablation , Myocardial Ischemia , Tachycardia, Ventricular , Humans , Anti-Arrhythmia Agents/therapeutic use , Stroke Volume , Prospective Studies , Treatment Outcome , Ventricular Function, Left , Australia/epidemiology , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/etiology , Myocardial Ischemia/surgery , Catheter Ablation/methods , Randomized Controlled Trials as Topic , Multicenter Studies as Topic
4.
J Interv Card Electrophysiol ; 66(1): 203-213, 2023 Jan.
Article En | MEDLINE | ID: mdl-35353320

BACKGROUND: Women are under-represented in many key studies and trials examining outcomes of catheter ablation (CA) for ventricular arrhythmias (VA). We compared characteristics between men and women undergoing their first catheter ablation for VA at a single centre over 10 years. METHODS: The clinical, procedural characteristics and outcomes of 287 consecutive patients (male = 182, female = 105), undergoing their first CA at our centre over 10 years were compared according to sex and underlying heart disease. RESULTS: In the ablation population, women were younger, had fewer co-morbidities, were less likely to have ischemic cardiomyopathy (ICM) and VA storm and were more likely to have idiopathic VA and premature ventricular complexes as the indication for ablation (P < 0.05 for all). Amongst idiopathic and non-ischemic cardiomyopathy (NICM) subgroups, baseline characteristics were similar; amongst ICM, women were younger and had higher numbers of drug failure pre-ablation (P = 0.05). Women were similar to men in all procedural characteristics, acute procedural success and complications, regardless of underlying heart disease. At median follow-up of 666 days, VA-free survival, overall mortality and survival free of death or transplant were comparable in both groups. Sex was not a predictor of these outcomes, after accounting for clinical and procedural characteristics. CONCLUSION: Women represented 36% of the real-world population at our centre referred for CA of VA. There are key differences in clinical features of women versus men referred for VA ablation. Despite these differences, VA ablation in women can be accomplished with similar success and complication rates to men, regardless of underlying heart disease.


Cardiomyopathies , Catheter Ablation , Heart Diseases , Myocardial Ischemia , Tachycardia, Ventricular , Ventricular Premature Complexes , Humans , Male , Female , Tachycardia, Ventricular/surgery , Treatment Outcome , Myocardial Ischemia/complications , Ventricular Premature Complexes/surgery , Catheter Ablation/adverse effects , Cardiomyopathies/complications , Cardiomyopathies/surgery
5.
Circ Arrhythm Electrophysiol ; 15(12): e011129, 2022 12.
Article En | MEDLINE | ID: mdl-36399370

BACKGROUND: Ventricular tachycardia (VT) storm is associated with significantly increased morbidity, mortality, and exponential healthcare utilization. Although catheter ablation (CA) may be curative, there are limited data directly comparing outcomes of early CA with initial medical therapy. METHODS: We compared outcomes of patients presenting with VT storm treated with initial CA versus those treated with initial medical therapy during their first storm presentation in an observational study. Retrospective data from the host institution from January 2014 to April 2020 of 129 patients with their first VT storm presentation were analyzed (58 underwent initial CA, 71 underwent treatment with initial medical therapy). Outcomes were compared in follow-up. RESULTS: Median time to initial CA was 6 days. Over a median follow-up of 702 days, patients who underwent initial CA compared with those treated with initial medical therapy had significantly less: (i) VA recurrence (43% versus 92%; P=0.002); (ii) VT storm recurrence (28% versus 73%; P<0.001); (iii) composite end point of death, heart transplant, VT storm recurrence, and VT-related hospitalization (47% versus 89%; P=0.002); (iv) iatrogenic complications (at 12 months: 17% versus 45%; P<0.001); (v) cardiovascular-related hospitalizations (50% versus 89%; P=0.01); (vi) total number of hospitalizations (median 1 versus 4; P<0.001); and (vi) cumulative days in hospital (median 0.5 versus 18; P<0.001). There were no intraprocedural deaths in patients treated with early CA. CONCLUSION: In an observational setting in which patients presenting with storm, early CA appears superior to initial medical therapy in terms of VT recurrence, storm recurrence, iatrogenic complications, cardiovascular hospitalizations, and cumulative days in hospital in follow-up.


Catheter Ablation , Tachycardia, Ventricular , Humans , Treatment Outcome , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Retrospective Studies , Catheter Ablation/adverse effects , Iatrogenic Disease , Recurrence
6.
Heart Lung Circ ; 31(11): 1432-1449, 2022 Nov.
Article En | MEDLINE | ID: mdl-36109292

Cardiac arrhythmias are associated with significant morbidity, mortality and economic burden on the health care system. Detection and surveillance of cardiac arrhythmias using medical grade non-invasive methods (electrocardiogram, Holter monitoring) is the accepted standard of care. Whilst their accuracy is excellent, significant limitations remain in terms of accessibility, ease of use, cost, and a suboptimal diagnostic yield (up to ∼50%) which is critically dependent on the duration of monitoring. Contemporary wearable and handheld devices that utilise photoplethysmography and the electrocardiogram present a novel opportunity for remote screening and diagnosis of arrhythmias. They have significant advantages in terms of accessibility and availability with the potential of enhancing the diagnostic yield of episodic arrhythmias. However, there is limited data on the accuracy and diagnostic utility of these devices and their role in therapeutic decision making in clinical practice remains unclear. Evidence is mounting that they may be useful in screening for atrial fibrillation, and anecdotally, for the diagnosis of other brady and tachyarrhythmias. Recently, there has been an explosion of patient uptake of such devices for self-monitoring of arrhythmias. Frequently, the clinician is presented such information for review and comment, which may influence clinical decisions about treatment. Further studies are needed before incorporation of such technologies in routine clinical practice, given the lack of systematic data on their accuracy and utility. Moreover, challenges with regulation of quality standards and privacy remain. This state-of-the-art review summarises the role of novel ambulatory, commercially available, heart rhythm monitors in the diagnosis and management of cardiac arrhythmias and their expanding role in the diagnostic and therapeutic paradigm in cardiology.


Atrial Fibrillation , Wearable Electronic Devices , Humans , Electrocardiography, Ambulatory/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Electrocardiography
7.
Heart Lung Circ ; 31(8): 1064-1074, 2022 Aug.
Article En | MEDLINE | ID: mdl-35643798

BACKGROUND: There are differences in substrate and ablation approaches for ventricular tachycardia (VT) in ischaemic (ICM) and non-ischaemic cardiomyopathy (NICM). OBJECTIVE: To perform a systematic review and meta-analysis comparing clinical and procedural characteristics/outcomes of VT ablation in ICM versus NICM. METHODS: Electronic databases were searched for comparative studies reporting outcomes of VT ablation in patients with ICM and NICM. Primary outcomes were acute procedural success, VT recurrence and long-term mortality. Meta-analyses were performed using random-effects modelling. RESULTS: Thirty-one (31) studies (7,473 patients; 4,418 ICM and 3,055 NICM) were included. Patients with ICM were significantly older (67.0 vs 55.3 yrs), more commonly male (89% vs 79%), had lower left ventricular ejection fraction (29% vs 38%) were less likely to undergo epicardial access (11% vs 36%) and were more likely to require haemodynamic support during ablation (relative risk [RR] 1.30; 95% CI 1.01-1.69). Acute procedural success (i.e. non-inducibility of VT) was higher in the ICM cohort (RR 1.10, 95% CI 1.05-1.15). Recurrence of VT at follow-up was significantly lower in the ICM cohort (RR 0.77; 95% CI 0.70-0.84). Peri-procedural mortality, incidence of procedural complications and long-term mortality were not significantly different between the cohorts. CONCLUSIONS: NICM and ICM patients undergoing VT ablation are fundamentally different in their clinical characteristics, ablation approaches, acute procedural outcomes and likelihood of VA recurrence. VT ablation in NICM has a lower likelihood of procedural success with increased risk of VA recurrence, consistent with known challenging arrhythmia substrate.


Cardiomyopathies , Catheter Ablation , Myocardial Ischemia , Tachycardia, Ventricular , Cardiomyopathies/complications , Cardiomyopathies/surgery , Catheter Ablation/adverse effects , Humans , Male , Myocardial Ischemia/complications , Myocardial Ischemia/surgery , Recurrence , Stroke Volume , Treatment Outcome , Ventricular Function, Left
8.
Heliyon ; 7(12): e08538, 2021 Dec.
Article En | MEDLINE | ID: mdl-34917813

BACKGROUND: There are limited data comparing remote magnetic navigation (RMN) to contemporary techniques of manual-guided ventricular arrhythmia (VA) catheter ablation. OBJECTIVES: We compared acute and long-term outcomes of VA ablation guided by either RMN or contemporary manual techniques in patients with structural heart disease. METHODS: From 2010-2019, 192 consecutive patients, with ischemic cardiomyopathy (ICM) or non-ischemic cardiomyopathy (NICM) underwent catheter ablation for sustained ventricular tachycardia (VT) or premature ventricular complexes (PVCs), using either RMN (n = 60) or manual (n = 132) guided techniques. Acute success and VA-free survival were compared. RESULTS: In ICM, acute procedural success was comparable between the 2 techniques (manual 43.5% vs. RMN 29%, P = 0.11), as was VA-free survival (manual 83% vs. RMN 74%, P = 0.88), and survival free from cardiac transplantation and all-cause mortality (manual 88% vs. RMN 87%, P = 0.47), both at 12-months after final ablation. In NICM, manual compared to RMN guided, had superior acute procedural success (manual 46% vs. RMN 19%, P = 0.003) and VA-free survival 12-months after final ablation (manual 79% vs. RMN 41%, P = 0.004), but comparable survival free from cardiac transplantation and all-cause mortality 12-months after final ablation (manual 95% vs. RMN 90%, P = 0.52). Procedural duration was shorter in both subgroups undergoing manual guided ablation, whereas fluoroscopy dose and complication rates were comparable. CONCLUSION: RMN provides similar outcomes to manual ablation in patients with ICM. In NICM however, acute success, and long-term VA-free survival was better with manual ablation. Prospective, multi-centre randomised trials comparing contemporary manual and RMN systems for VA catheter ablation are needed.

9.
J Arrhythm ; 37(6): 1506-1511, 2021 Dec.
Article En | MEDLINE | ID: mdl-34887955

We reviewed the different approaches used for central vein access during insertion of cardiac implantable electronic devices. The benefits and hazards of each approach (cephalic vein cutdown, axillary vein cannulation using venography and ultrasound) are discussed. Each approach has its advantages and hazards that need to be considered for the individual patient and balanced against the skills of the operator. The benefits of ultrasound guided venous access in reducing radiation exposure to the patient and implanter, avoiding the need for angiographic contrast and in minimizing the risk of pneumothorax and inadvertent arterial puncture are highlighted. Trainees should be taught each approach to deal with patient variability. Ultrasound guidance should be considered as a mainstream option for most patients.

10.
JACC Clin Electrophysiol ; 7(4): 471-481, 2021 04.
Article En | MEDLINE | ID: mdl-33888268

OBJECTIVES: This study sought to determine whether a novel impedance thermal imaging system (ITIS) provides an impedance measurement that is better correlated with lesion dimensions than circuit impedance during radiofrequency (RF) ablation. BACKGROUND: A 5- to 10-Ω impedance drop is clinically used to corroborate an effective RF ablation lesion. However, the contribution of local tissue heating to circuit impedance change is small and dependent on the local environment of the catheter and placement of the grounding patch. METHODS: ITIS uses ablation catheter and skin electrodes to perform 4-terminal impedance measurements with separate voltage sensing and current injection electrode pairs. Seven sheep underwent endocardial ventricular irrigated RF ablation at 40 W for 60 s. ITIS impedance and circuit impedance were both measured throughout ablation. When the sheep were sacrificed, ablation lesions were cut along their long axis; the depth, width, and surface area of the cut surface were measured. RESULTS: A total of 68 RF ablations were performed, with a median depth of 3.5 mm (interquartile range [IQR]: 2.1 to 4.9 mm), width of 8.3 mm (IQR: 5.7 to 10.8 mm), and surface area of 23.8 mm2 (IQR: 9.3 to 43.0 mm2). ITIS impedance change had good correlation with lesion depth, width, and surface area (R = 0.76, R = 0.87, and R = 0.87, respectively); and superior to circuit impedance for lesion depth, width, and surface area (p = 0.0018, p = 0.0004, and p = 0.0001, respectively). CONCLUSIONS: By optimizing the current path and using 4-terminal impedance measurement during RF ablation, the contribution of tissue temperature changes to measured impedance is better standardized to provide a more reliable measure than conventional ablation circuit impedance.


Catheter Ablation , Animals , Electric Impedance , Electrodes , Equipment Design , Heart Ventricles/surgery , Sheep
12.
Clin Res Cardiol ; 110(4): 544-554, 2021 Apr.
Article En | MEDLINE | ID: mdl-32880676

BACKGROUND: Atrial fibrillation (AF) is an important arrhythmia in hypertrophic cardiomyopathy (HCM). OBJECTIVES: To conduct a systematic review of published literature to: (a) assess the incidence of AF in HCM and (b) examine the impact of AF on risk of thromboembolism, heart failure, sudden death and mortality in HCM. METHODS: Search of all major databases (Pubmed, MEDLINE, Embase, Cochrane, Scopus, Web of Science) was performed to April 2020 using the search terms "atrial fibrillation" AND/OR "hypertrophic cardiomyopathy" in the title or abstract. 51 of the 1,565 citations met the inclusion criteria. RESULTS: Using random-effects modelling, the estimated pooled prevalence of AF amongst 21,887 HCM patients (36 studies) was 22.3% (95%, 19.9-24.8) and the pooled incidence of AF was 2.5 cases per person-years (95% CI 1.9-3.0). 15,444 patients from 28 studies were included in analysis of outcome data (mean age was 49.9 years; 32.7% female; mean LVEF 69%). Over a median follow up duration of 6.9 years (range 2.8-11.7 years), AF, compared to sinus rhythm (SR), was associated with significantly increased risk of thromboembolism [relative risk (RR) 7.0; 95% CI 4.6-10.7; I2 = 57%], heart failure (RR 2.8; 95% CI 1.6-4.6; I2 = 82%), sudden death (RR 1.7; 95% CI 1.3-2.3; I2 = 0%), and all-cause mortality (RR 2.5; 95% CI 1.8-3.4; I2 = 69%). CONCLUSIONS: AF is highly prevalent in patients with HCM. The presence of AF is associated with major adverse clinical outcomes. These findings suggest that both, aggressive screening and treatment of AF, are likely to have major prognostic impact on outcomes in HCM. Incidence, prevalence and prognostic impact of AF in HCM. In this systematic review, AF incidence was 2.5 cases per-person years, prevalence was 22.3%. AF in HCM was associated with a seven-fold increased risk of thromboembolism, 2.8-fold increased risk of heart failure, 1.7-fold increased risk of sudden death and 2.5-fold increased risk of all-cause mortality.


Atrial Fibrillation/complications , Cardiomyopathy, Hypertrophic/complications , Risk Assessment , Thromboembolism/epidemiology , Global Health , Humans , Incidence , Thromboembolism/etiology
13.
Heart Lung Circ ; 30(4): 555-566, 2021 Apr.
Article En | MEDLINE | ID: mdl-33153905

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) can provide circulatory support in high-risk patients undergoing drug refractory ventricular tachycardia (VT) ablation procedures. We report experience using VA-ECMO in a pre-emptive approach for high-risk patients with VT storm and previously ineffective ablation procedures. METHODS AND RESULTS: Four (4) patients with drug refractory ventricular tachycardia (mean age 61±3 years; left ventricular ejection fraction 21±5%) presenting for VT ablation had pre-emptive VA-ECMO. All patients during current admission had VT storm. Pre-ablation, 22 total monomorphic VTs (cycle length 402±69 ms) were induced or spontaneously observed (median of 4, IQR25-75% 1-6). At the end of the procedure, 86% of all inducible VTs were rendered non-inducible. Median hospitalisation following VA-ECMO supported ablation was 5 days (IQR25-75% 3-12). During follow-up (median 138 days [IQR25-75% 57-277]), VT recurred in one patient as an isolated episode reverted by anti-tachycardia pacing. There was a 99% reduction in VT burden post ablation. One (1) patient died of cardiogenic shock within 24 hours whilst still on VA-ECMO, all other patients were successfully weaned off support and discharged. Two (2) patients underwent cardiac transplantation at 199 and 512 days post ablation following implantation of ventricular assist devices for worsening heart failure. CONCLUSIONS: The pre-emptive use of VA-ECMO for high-risk patients undergoing catheter ablation for VT storm was found to be effective in maintaining haemodynamic status, and allowing successful mapping and catheter ablation for VT.


Catheter Ablation , Extracorporeal Membrane Oxygenation , Tachycardia, Ventricular , Australia/epidemiology , Humans , Middle Aged , Stroke Volume , Tachycardia, Ventricular/surgery , Treatment Outcome , Ventricular Function, Left
14.
Heart Lung Circ ; 29(6): e57-e68, 2020 Jun.
Article En | MEDLINE | ID: mdl-32451232

The COVID-19 pandemic poses a significant stress on health resources in Australia. The Heart Rhythm Council of the Cardiac Society of Australia and New Zealand aims to provide a framework for efficient resource utilisation balanced with competing risks when appropriately treating patients with cardiac arrhythmias. This document provides practical recommendations for the electrophysiology (EP) and cardiac implantable electronic devices (CIED) services in Australia. The document will be updated regularly as new evidence and knowledge is gained with time.


Betacoronavirus , Coronavirus Infections , Defibrillators, Implantable , Electrophysiologic Techniques, Cardiac , Pandemics , Pneumonia, Viral , Australia/epidemiology , COVID-19 , Coronavirus Infections/epidemiology , Coronavirus Infections/physiopathology , Coronavirus Infections/therapy , Humans , Pneumonia, Viral/epidemiology , Pneumonia, Viral/physiopathology , Pneumonia, Viral/therapy , SARS-CoV-2
15.
Circ Arrhythm Electrophysiol ; 13(5): e008251, 2020 05.
Article En | MEDLINE | ID: mdl-32299229

BACKGROUND: Radiofrequency ablation depth can be inadequate to reach intramural or epicardial substrate, and energy delivery in the pericardium is limited by penetration through epicardial fat and coronary anatomy. We hypothesized that open irrigated microwave catheter ablation can create deep myocardial lesions endocardially and epicardially though fat while acutely sparing nearby the coronary arteries. METHODS: In-house designed and constructed irrigated microwave catheters were tested in in vitro phantom models and in 15 sheep. Endocardial ablations were performed at 140 to 180 W for 4 minutes; epicardial ablations via subxiphoid access were performed at 90 to 100 W for 4 minutes at sites near coronary arteries. RESULTS: Epicardial ablations at 90 to 100 W produced mean lesion depth of 10±4 mm, width 18±10 mm, and length 29±8 mm through median epicardial fat thickness of 1.2 mm. Endocardial ablations at 180 W reached depths of 10.7±3.3 mm, width of 16.6±5 mm, and length of 20±5 mm. Acute coronary occlusion or spasm was not observed at a median separation distance of 2.7 mm (IQR, 1.2-3.4 mm). Saline electrodes recorded unipolar and bipolar electrograms; microwave ablation caused reductions in voltage and changes in electrogram morphology with loss of pace-capture. In vitro models demonstrated the heat sink effect of coronary flow, as well as preferential microwave coupling to myocardium and blood as opposed to lung and epicardial fat phantoms. CONCLUSIONS: Irrigated microwave catheter ablation may be an effective ablation modality for deep ventricular lesion creation with capacity for fat penetration and sparing of nearby coronary arteries because of cooling endoluminal flow. Clinical translation could improve the treatment of ventricular tachycardia arising from mid myocardial or epicardial substrates.


Adipose Tissue/surgery , Catheter Ablation , Coronary Vessels/injuries , Heart Injuries/prevention & control , Heart Ventricles/surgery , Microwaves , Pericardium/surgery , Therapeutic Irrigation , Action Potentials , Adipose Tissue/pathology , Animals , Cardiac Catheters , Catheter Ablation/adverse effects , Catheter Ablation/instrumentation , Coronary Vessels/physiopathology , Heart Injuries/etiology , Heart Injuries/physiopathology , Heart Rate , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Male , Microwaves/adverse effects , Models, Animal , Pericardium/pathology , Pericardium/physiopathology , Sheep, Domestic , Therapeutic Irrigation/adverse effects , Therapeutic Irrigation/instrumentation , Time Factors
16.
JACC Clin Electrophysiol ; 6(1): 56-69, 2020 01.
Article En | MEDLINE | ID: mdl-31971907

OBJECTIVES: This study sought to summarize the procedural characteristics and outcomes of patients with structural heart disease (SHD) who have focal ventricular tachycardia (VT). BACKGROUND: Scar-mediated re-entry is the predominant mechanism of VT in SHD. Some SHD patients may have a focal VT mechanism that remains poorly described. METHODS: An extended induction protocol incorporating programmed electrical stimulation, right ventricular burst pacing and isoprenaline was used to elucidate both re-entrant and focal VT mechanisms. RESULTS: Eighteen of 112 patients (16%) with SHD undergoing VT ablation over 2 years had a focal VT mechanism elucidated (mean age 66±13 years; ejection fraction 46±14%; nonischemic cardiomyopathy 10). Repetitive failure of termination with antitachycardia pacing (ATP) (69% of patients) or defibrillator shocks (56%) was a common feature of focal VTs. A median of 3 VTs per patient were inducible (28 focal VTs, 34 re-entrant VTs; 53% of patients had both focal and re-entrant VT mechanism). Focal VTs more commonly originated from the right ventricle (RV) than the left ventricle (LV) (67% vs. 33%, respectively). In the RV, the RV outflow tract was the most common site (33% of all focal VTs), followed by the RV moderator band (22%), apical septal RV (6%), and lateral tricuspid annulus (6%). The lateral LV (non-Purkinje) was the most common LV focal VT site (16%), followed by the papillary muscles (17%). After median follow-up of 289 days, 78% of patients remained arrhythmia-free; no patients had recurrence of focal VT at repeat procedure. In patients with recurrence, defibrillator therapies were significantly reduced from a median of 53 ATP episodes pre-ablation to 10 ATP episodes post-ablation. During follow-up, 2 patients (11%) underwent repeat VT ablation; none had recurrence of focal VT. CONCLUSIONS: Focal VTs are common in patients with SHD and often coexist with re-entrant forms of VT. High failure rate of defibrillator therapies was a common feature of focal VT mechanisms. Uncovering and abolishing focal VT may further improve outcomes of catheter ablation in SHD.


Catheter Ablation , Tachycardia, Ventricular , Aged , Cardiomyopathies , Female , Heart/diagnostic imaging , Heart/physiopathology , Humans , Male , Middle Aged , Myocardium/pathology , Prevalence , Retrospective Studies , Treatment Outcome
18.
JACC Cardiovasc Interv ; 12(12): 1109-1120, 2019 06 24.
Article En | MEDLINE | ID: mdl-31221301

OBJECTIVES: This study sought to develop a method to assess renal sympathetic nerve function through localization and pacing of aorticorenal ganglia (ARG). BACKGROUND: Transcatheter renal denervation procedures often fail to produce complete renal denervation because of the lack of a physiological procedural endpoint. METHODS: High-frequency pacing was performed in the inferior vena cava and aorta in sheep (n = 19) to identify ARG pace-capture sites. Group A (n = 5) underwent injection at the ARG pace-capture site for histological verification, group B (n = 6) underwent unilateral irrigated radiofrequency ablation of ARG pace-capture sites and assessment of renal innervation at 1 week post-procedure; and group C (n = 8) underwent ARG pacing before and 2 to 3 weeks after unilateral microwave renal denervation. RESULTS: ARG pace-capture responses were observed at paired discrete sites above the ipsilateral renal artery eliciting a change in mean arterial blood pressure of 22.2 (interquartile range [IQR]: 15.5 to 34.3 mm Hg; p < 0.001) with concurrent ipsilateral renal arterial vasoconstriction, change in main renal artery diameter of -0.42 mm (IQR: -0.64 to -0.24 mm; p < 0.0001), and without consistent contralateral renal vasoconstriction. Sympathetic ganglionic tissue was observed at ARG pace-capture sites, and ganglion ablation led to significant ipsilateral renal denervation. Circumferential renal denervation resulted in immediate and sustained abolition of ARP pacing-induced renal vasoconstriction and significant ipsilateral renal denervation. CONCLUSIONS: Transvascular ARG pace-capture is feasible and recognized by concurrent hypertensive and ipsilateral renal arterial vasoconstrictive responses. Abolition of ARG pacing-induced vasoconstriction may indicate successful renal sympathetic denervation and serve as a physiological procedural endpoint to guide transcatheter renal denervation.


Aorta/innervation , Catheter Ablation , Endpoint Determination , Ganglia, Sympathetic/physiology , Kidney/blood supply , Microwaves , Renal Artery/innervation , Sympathectomy , Action Potentials , Animals , Blood Pressure , Catheter Ablation/adverse effects , Electric Stimulation , Male , Microwaves/adverse effects , Sheep, Domestic , Time Factors , Vasoconstriction
19.
J Hypertens ; 37(10): 2083-2092, 2019 10.
Article En | MEDLINE | ID: mdl-31033726

BACKGROUND: Clinical studies of transcatheter radiofrequency renal denervation for treating hypertension have been hampered by the lack of consistent denervation efficacy. We aimed to demonstrate the short-term efficacy and safety of transcatheter microwave renal denervation. METHODS: A novel 7F microwave system was validated in a sheep model of unilateral renal denervation. Up to two microwave ablations were delivered to each artery with maximum power at 100-110 W for 480 s. RESULTS: Catheter deployment and ablation was successful in all 19 targeted vessel segments, and ablation produced substantial circumferential perivascular injury; median ablation lesion area greater than 395 [interquartile range (IQR) 251-437] mm, depth 17.1 (IQR 15.8-18.4) mm, length 16 (IQR 12-20) mm, without collateral visceral injury. Limiting power to 100 W minimized arterial injury, while maintaining a deep circumferential perivascular ablation. Microwave denervation reduced median functional sympathetic nerve surface area at the renal hilum on antityrosine hydroxylase staining by 100% (IQR 87-100%, P = 0.0039), and median renal cortical norepinephrine content by 83% (IQR 76-92%, P = 0.0078), compared to the paired control kidney at 2-3 weeks postprocedure. CONCLUSION: Transcatheter microwave ablation can produce deep circumferential perivascular ablations over a long segment of the renal artery without significant arterial or collateral visceral injury to provide effective renal denervation.


Catheter Ablation/methods , Denervation/methods , Kidney/innervation , Animals , Female , Kidney/blood supply , Kidney/metabolism , Microwaves , Norepinephrine/metabolism , Sheep , Sympathetic Nervous System/physiopathology
...