Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 53
Filter
2.
J Arrhythm ; 40(4): 830-838, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39139884

ABSTRACT

Background: Currently, two types of cryoballoon (CB) systems are available for catheter ablation of atrial fibrillation (AF). Since the POLARx (Boston Scientific) is softer during freezing than the Arctic Front Advance Pro (AFA-Pro; Medtronic), it tends to go more deeply into the pulmonary vein (PV), risking PV stenosis. Methods: Ninety-one patients underwent initial CB ablation for paroxysmal AF (AFA-Pro 56; POLARx 35). Twenty-six from each group were extracted using propensity score matching. The PV cross-sectional area (PVA) was measured by tracing the area within the PV plane at 5-mm intervals from the PV ostium in a distal direction for 20 mm or to the bifurcation in each PV. The PVA was compared before and 3 months after ablation. Results: Time to balloon temperatures of -30 and - 40°C was significantly shorter and the nadir temperature was significantly lower with POLARx than with AFA-Pro. In the left inferior (LI) PV and right superior (RS) PV, the freezing balloon position was significantly deeper in POLARx than in AFA-pro. The freezing position in RSPV with mild to moderate narrowing was deeper than those without (10.2 ± 3.3 mm vs. 8.2 ± 1.8 mm, p = .01). In RSPV, the reduction of PVA tended to be greater with the POLARx than with the AFA-Pro (26.1% ± 14.1% vs. 19.9% ± 10.3%, p = .07). Conclusion: There was no significant difference in the incidence of PV stenosis between POLARx and AFA-Pro. However, if POLARx goes deep into the PVs, we will still have to be careful.

3.
Article in English | MEDLINE | ID: mdl-39107545

ABSTRACT

Pulmonary vein stenosis (PVS) can occasionally occur in the follow-up after pulmonary vein isolation (PVI) for atrial fibrillation (AF). During PVI, ablation is performed at the PV ostium or distal part, leading to tissue damage. This damage can result in fibrosis of the necrotic myocardium, proliferation, and thickening of the vascular intima, as well as thrombus formation, further advancing PVS. Mild-to-moderate PVS often remains asymptomatic, but severe PVS can cause symptoms, such as dyspnea, cough, fatigue, decreased exercise tolerance, chest pain, and hemoptysis. These symptoms are due to pulmonary hypertension and pulmonary infarction. Imaging evaluations such as contrast-enhanced computed tomography are essential for diagnosing PVS. Early suspicion and detection are necessary, as underdiagnosis can lead to inappropriate treatment, disease progression, and poor outcomes. The long-term prognosis of PVS remains unclear, particularly regarding the impact of mild-to-moderate PVS over time. PVS treatment focuses on symptom management, with no established definitive solutions. For severe PVS, transcatheter PV angioplasty is performed, though the risk of restenosis remains high. Restenosis and reintervention rates have improved with stent implantation compared with balloon angioplasty. The role of subsequent antiplatelet therapy remains uncertain. Dedicated evaluation is essential for accurate diagnosis and appropriate management to avoid significant long-term impacts on patient outcomes.

4.
J Arrhythm ; 40(3): 520-526, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38939774

ABSTRACT

Background: Hyperuricemia (HU) has been reported to be associated with a high incidence of atrial fibrillation (AF). However, the relationship between HUA and recurrent AF after catheter ablation (CA) is unclear. Methods: Four hundred consecutive AF patients (paroxysmal/persistent AF [PAF/PsAF]: 200/200) who underwent the initial CA were retrospectively enrolled. HU was defined as serum uric acid (SUA) level >7.0 mg/dL. We measured SUA levels 1 day before (pre-CA) and 1 month after CA (post-CA). A second-generation 28 mm cryoballoon was used for pulmonary vein isolation (PVI) for PAF, while PVI plus linear ablation (roof and mitral isthmus lines) by radiofrequency catheter was conducted for PsAF. Results: During 57 ± 24 months of follow-up, AF recurred in 16% and 42% in PAF and PsAF patients (p < .0001). Pre-CA SUA level in PsAF was significantly higher than that in PAF (6.5 ± 1.3 vs. 5.8 ± 1.3 mg/dL, p < .001). SUA level was significantly decreased after CA in both PAF and PsAF (5.8 ± 1.3 vs. 5.6 ± 1.3 mg/dL; p < .01 and 6.5 ± 1.3 vs. 6.1 ± 1.2 mg/dL; p < .0001, respectively). The association between pre-/post-CA HU and recurrent AF was not identified in PAF, while the incidence of post-CA HU was significantly higher in patients with recurrent AF than those without in PsAF (36% vs. 15%, p < .001). In multivariable analysis, longer AF duration and the presence of post-CA HU were identified as independent predictors of AF recurrence in PsAF (OR:1.01, 95%CI:1.003-1.011, p = .0001 and OR:2.77, 95%CI:1.333-5.755, p = .007, respectively). Conclusions: SUA level was significantly higher in PsAF than PAF patients. The presence of post-CA HU was strongly related to AF recurrence in PsAF patients.

5.
Circ Arrhythm Electrophysiol ; 17(6): e012635, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38804141

ABSTRACT

BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% (P<0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P=0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P=0.004, and odds ratio, 29.93; P<0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.


Subject(s)
Catheter Ablation , Echocardiography , Saline Solution , Steam , Tachycardia, Ventricular , Therapeutic Irrigation , Humans , Male , Female , Saline Solution/administration & dosage , Middle Aged , Catheter Ablation/adverse effects , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/diagnostic imaging , Aged , Embolism, Air/prevention & control , Embolism, Air/etiology , Embolism, Air/diagnostic imaging , Treatment Outcome , Risk Factors , Predictive Value of Tests , Electric Impedance
6.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1353-1364, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38819347

ABSTRACT

BACKGROUND: Catheter ablation for atrial fibrillation (AF) including pulmonary vein isolation and possibly further substrate ablation is the most common electrophysiological procedure. Severe complications are uncommon, but their detailed assessment in a large worldwide cohort is lacking. OBJECTIVES: The aim of this study was to determine the incidence of periprocedural severe complications and to provide a detailed characterization of the diagnostic evaluation and management of these complications in patients undergoing AF ablation. METHODS: Individual patient data were collected from 23 centers worldwide. Limited data were collected for all patients who underwent catheter ablation, and an expanded series of data points were collected for patients who experienced severe complications during periprocedural follow-up. Incidence, predictors, patient characteristics, management details, and overall outcomes of patients who experienced ablation-related complications were investigated. RESULTS: Data were collected from 23 participating centers at which 33,879 procedures were performed (median age 63 years, 30% women, 71% radiofrequency ablations). The incidence of severe complications (n = 271) was low (tamponade 6.8‰, stroke 0.97‰, cardiac arrest 0.41‰, esophageal fistula 0.21‰, and death 0.21‰). Age, female sex, a dilated left atrium, procedure duration, and the use of radiofrequency energy were independently associated with the composite endpoint of all severe complications. Among patients experiencing tamponade, 13% required cardiac surgery. Ninety-three percent of patients with complications were discharged directly home after a median length of stay of 5 days (Q1-Q3: 3-7 days). CONCLUSIONS: This large worldwide collaborative study highlighted that tamponade, stroke, cardiac arrest, esophageal fistula, and death are rare after AF ablation. Older age, female sex, procedure duration, a dilated left atrium, and the use of radiofrequency energy were associated with severe complications in this multinational cohort. One in 8 patients with tamponade required cardiac surgery.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Postoperative Complications , Registries , Humans , Atrial Fibrillation/surgery , Male , Female , Catheter Ablation/adverse effects , Middle Aged , Aged , Postoperative Complications/epidemiology , Incidence , Cardiac Tamponade/epidemiology , Cardiac Tamponade/etiology , Stroke/epidemiology , Esophageal Fistula/epidemiology , Esophageal Fistula/etiology
7.
Heart Vessels ; 39(7): 616-625, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38526754

ABSTRACT

Accurate measurement of the pulmonary vein dimension (PVD) is important for determining stenosis and efficacy following pulmonary vein isolation (PVI). Little is known about the quantitative evaluation of the impact of the cardiac cycle on pulmonary vein (PV) morphology before and after PVI. This study aims to investigate variations in the ostial size of the PV during the cardiac cycle before and after PVI and the effect of the cardiac cycle on PV stenosis and reduction rate using cardiac computed tomography (CT). Sixty-eight patients with atrial fibrillation who underwent cardiac CT before and after PVI at our institution between 23 January 2021 and 5 February 2022 were retrospectively analyzed. The maximum and minimum PVD were measured at each segment before and after the PV. Each PV was evaluated according to the PVD reduction rate (ΔPVD), calculated as follows: (1 - post-PVD/pre-PVD) × 100 (%). The average dimension of all PVs at the end-diastolic frame was significantly reduced compared to that at the end-systolic frame before PVI. The average dimensions of the right superior and right inferior PV at the end-diastolic frame were significantly reduced compared with those at the end-systolic frame following PVI. The average reduction rate of dimension-classified stenosis of PVs, except for the left inferior PV at the end-diastolic frame, was significantly reduced compared with that at the end-systolic frame. The cardiac cycle affects PVD assessment, including PV stenosis, after PVI. PVD measurement is recommended to be unified to the end-systolic frame of the cardiac cycle to avoid underestimating PV stenosis before and after PVI, ensuring appropriate management and follow-up.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/physiopathology , Male , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Female , Retrospective Studies , Middle Aged , Catheter Ablation/methods , Aged , Stenosis, Pulmonary Vein/physiopathology , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/diagnosis , Stenosis, Pulmonary Vein/surgery , Treatment Outcome , Follow-Up Studies , Heart Rate/physiology
9.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38367008

ABSTRACT

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Subject(s)
Catheter Ablation , Radiofrequency Ablation , Tachycardia, Ventricular , Male , Humans , Middle Aged , Female , Saline Solution/adverse effects , Steam , Prospective Studies , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Tachycardia, Ventricular/surgery , Therapeutic Irrigation/adverse effects
10.
JACC Clin Electrophysiol ; 10(2): 193-202, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38069975

ABSTRACT

BACKGROUND: Risks of radiofrequency catheter ablation for ventricular arrhythmias include emboli and bleeding complications but data on antithrombotic regimens are limited and guidelines do not specify a systematic approach. OBJECTIVES: This study sought to assess embolic and bleeding complications in relation to pre-periprocedure and post-periprocedure antithrombotic regimens. METHODS: Prospective assessment for complications was performed for 663 endocardial radiofrequency catheter ablation procedures in 616 consecutive patients (median age 64 years [Q1-Q3: 54-73 years], 70.3% men, 71.6% with cardiomyopathy, 44.5% with sustained ventricular tachycardia). RESULTS: There were 2 strokes (0.3%; 95% CI: 0.0%-0.8%), 1 transient ischemic attack (0.15%), and 2 pulmonary emboli (0.3%). There were 39 bleeding complications (5.9%) including 11 pericardial effusions (1.7%), and 28 related to vascular access (4.2%). Consistent with the prevalence of coronary artery disease (47.5%), atrial fibrillation (30.0%), and prior stroke (10.6%), preprocedure, 464 patients (70.0%) were taking antithrombotic agents including 220 (33.2%) taking aspirin alone (ASA), and 163 (24.6%) taking warfarin or a direct acting oral anticoagulant (DOAC). Preprocedure non-ASA antiplatelet use (OR: 2.846; P = 0.011) and DOAC use (OR: 2.585; P = 0.032) were associated with risk of bleeding complications. Following ablation, 49.8% of patients were treated with ASA 325 mg/d and 30.3% received DOACs or warfarin. New DOAC or warfarin administration was initiated in only 6.6% of patients. Overall, 39.7% of patients continued the same preprocedure antithrombotic regimen. CONCLUSIONS: Stroke is a rare complication of radiofrequency catheter ablation for ventricular arrhythmia using ASA 325 mg/d as a minimal postprocedure regimen with more potent regimens for selected patients.


Subject(s)
Atrial Fibrillation , Stroke , Male , Humans , Middle Aged , Female , Warfarin/adverse effects , Anticoagulants/adverse effects , Hemorrhage/etiology , Hemorrhage/chemically induced , Fibrinolytic Agents , Prospective Studies , Stroke/etiology , Stroke/epidemiology , Atrial Fibrillation/surgery , Aspirin/adverse effects
11.
Pacing Clin Electrophysiol ; 47(3): 437-439, 2024 03.
Article in English | MEDLINE | ID: mdl-37260106

ABSTRACT

We report a case of atrial fibrillation (AF) recurrence after pulmonary vein isolation, which patient had AF trigger in the superior vena cava (SVC) near the sinus node (SN). The ultra-high-resolution mapping revealed that SN located within the SVC and the atrial activation from the SN to SVC propagated in both septal and lateral direction, then upward with circumventing the spontaneous conduction block identified just above and lateral SN (upper hemisphere). We successfully isolated SVC including the ectopic origin at the same level as the SN by utilizing the spontaneous conduction block line around the SN without any complication.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Vena Cava, Superior/surgery , Atrial Fibrillation/surgery , Sinoatrial Node , Heart Atria , Heart Block , Pulmonary Veins/surgery
13.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Article in English | MEDLINE | ID: mdl-37258224

ABSTRACT

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Stenosis, Pulmonary Vein , Humans , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology , Cross-Sectional Studies , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Lasers
14.
Circ Arrhythm Electrophysiol ; 16(2): e010889, 2023 02.
Article in English | MEDLINE | ID: mdl-36602818

ABSTRACT

BACKGROUND: Initiation of ventricular tachycardia (VT) by programmed electrical stimulation (PES) has an important role to allow mapping and assess ablation end points. We hypothesized that substrate mapping may alter VT inducibility by mechanical bumping of critical sites. METHODS: Subjects with left ventricular scar-related VT that was inducible by PES who were undergoing ablation were included. PES was repeated after substrate mapping (Group I) or after time under sedation/anesthesia during which additional imaging and transeptal puncture were performed without substrate mapping (Group II). The response to the second PES was categorized as type I if the same VT was induced, type II if a different VT was induced, and type III if VT was not inducible. RESULTS: Twenty-eight patients (median age 66 years, 61% ischemic cardiomyopathy), 14 in Group I and 14 in Group II, were included. Age, time between initial and second PES, type of cardiomyopathy, ejection fraction, and anesthesia methods were not different between the 2 groups. Initial VT cycle length, however, was shorter in Group I (305 millisecond [range, 235-600] versus 350 millisecond [range, 235-600], P=0.016). Also, Group I required more extrastimuli to induce VT in PES 1 (2 [1-4] versus 2 [1-3], P=0.022). In Group I, following substrate mapping, the second PES induced the same VT in 3 patients (21%), a different VT in 9 (64%), and no VT in 2 (14%) patients. In contrast, in Group II the same VT was induced in 10 (71%) patients, a different VT in 3 (21%) and no VT in 1 (7%) patient (P=0.017). CONCLUSIONS: Mechanical effects of substrate mapping commonly alter inducibility of VT. This has important implications for catheter ablation procedure planning and acute assessment of outcome and can potentially account for some recurrent VTs that are not recognized at the time of the procedure.


Subject(s)
Anesthesia , Cardiomyopathies , Catheter Ablation , Myocardial Ischemia , Tachycardia, Ventricular , Humans , Aged , Cardiomyopathies/surgery , Catheter Ablation/methods , Treatment Outcome
15.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36194289

ABSTRACT

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Freezing , Cross-Sectional Studies , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome
16.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Article in English | MEDLINE | ID: mdl-35842800

ABSTRACT

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Bradycardia , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Follow-Up Studies , Humans , Male , Middle Aged , Recurrence , Sick Sinus Syndrome/therapy , Tachycardia/diagnosis , Tachycardia/surgery , Treatment Outcome
17.
Circ J ; 86(8): 1229-1236, 2022 07 25.
Article in English | MEDLINE | ID: mdl-35786690

ABSTRACT

BACKGROUND: Pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is rare; however, it remains a serious complication. PV angioplasty is reportedly an effective therapy; however, a dedicated device for PV angioplasty has not been developed, and the detailed procedural methods remain undetermined. This study describes the symptoms, indications, treatment strategies, and long-term outcomes for PV stenosis after AF ablation.Methods and Results: This study retrospectively analyzed 7 patients with PV stenosis after catheter ablation for AF and who had undergone PV angioplasty at our hospital during 2015-2021. PV stenosis occurred in the left superior (5 patients) and left inferior (2 patients) PV. Six patients had hemoptysis, chest pain, and dyspnea. Seven de novo lesions were treated using balloon angioplasty (BA) (3 patients), a bare metal stent (BMS) (3 patients), and a drug-coated balloon (DCB) (1 patient). The restenosis rate was 42.9% (n=3; 2 patients in the BA group and 1 patient in the DCB group). The repeat treatment rate was 28.6% (2 patients in the BA group). Stenting was performed as repeat treatment. One patient with subsequent repeat restenosis development underwent BA. Ten PV angioplasties were performed; there were no major complications. CONCLUSIONS: Regarding PV angioplasty after ablation therapy for AF, stenting showed superior long-term PV patency than BA alone; therefore, it should be considered as a standard first-line approach.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Stenosis, Pulmonary Vein , Angioplasty/adverse effects , Angioplasty/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Constriction, Pathologic/complications , Humans , Pulmonary Veins/surgery , Retrospective Studies , Stenosis, Pulmonary Vein/diagnostic imaging , Stenosis, Pulmonary Vein/etiology , Stenosis, Pulmonary Vein/therapy , Treatment Outcome
18.
Int J Cardiol Heart Vasc ; 40: 101020, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35434257

ABSTRACT

Background: It was previously reported, based on a retrospective study, that preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation reduced the incidence of asymptomatic cerebral embolism (ACE). The present study aims to compare the incidence of ACE between a conventional and pre-inflation method during cryoballoon ablation in a prospective randomized controlled study. Methods: A total of 98 atrial fibrillation patients were enrolled and randomized into conventional and pre-inflation groups. Patients in the pre-inflation group received balloon massaging with preliminary extracorporeal balloon inflation in saline water before the cryoballoon was inserted into the body. Results: The baseline characteristics were similar between the two groups. Post-procedural 3-Tesla MRI revealed CE in 27.6% of patients. Symptomatic CE only occurred in two patients in the pre-inflation group. One patient had transient dysarthria and mild muscle weakness in one hand; the other patient complained of transient left upper limb weakness, left lower limb paresthesia and dysarthria. The incidence of ACE detected by cerebral MRI did not differ between the two groups to a statistically significant extent (conventional vs. pre-inflation; 22.9% vs. 29.2%; P = 0.49). In the multivariable analysis, eGFR was independently associated with the presence of ACE (odds ratio 0.95; 95% confidence interval 0.907-0.995; P = 0.03). Conclusion: In this prospective randomized study, the preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation had no impact on the incidence of ACE.

20.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34216250

ABSTRACT

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Subject(s)
Atrial Fibrillation , Atrial Premature Complexes , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Premature Complexes/diagnosis , Cryosurgery/adverse effects , Heart Rate , Humans , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
SELECTION OF CITATIONS