Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Lab Anim Res ; 40(1): 18, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741131

ABSTRACT

Community-acquired respiratory infection is the commonest cause of sepsis presenting to emergency departments. Yet current experimental animal models simulate peritoneal sepsis with intraperitoneal (I.P.) injection of lipopolysaccharide (LPS) as the predominant route. We aimed to compare the progression of organ injury between I.P. LPS and intranasal (I.N.) LPS in order to establish a better endotoxemia murine model of respiratory sepsis. Eight weeks old male BALB/c mice received LPS-Escherichia coli doses at 0.15, 1, 10, 20, 40 and 100 mg per kg body weight (e.g. LPS-10 is a dose of 10 mg/kg body weight). Disease severity was monitored by a modified Mouse Clinical Assessment Score for Sepsis (M-CASS; range 0-21). A M-CASS score ≥ 10 or a weight reduction of ≥ 20%, was used as a criterion for euthanasia. The primary outcome was the survival rate (either no death or no need for euthanasia). The progression of disease was specified as M-CASS, body weight, blood glucose, histopathological changes to lung, liver, spleen, kidney, brain and heart tissues. Survival rate in I.P. LPS-20 mice was 0% (2/3 died; 1/3 euthanized with M-CASS > 10) at 24 h. Survival rate in all doses of I.N. LPS was 100% (20/20; 3-4 per group) at 96 h. 24 h mean M-CASS post-I.P. LPS-10 was 6.4/21 significantly higher than I.N. LPS-10 of 1.7/21 (Unpaired t test, P < 0.05). Organ injury was present at 96 h in the I.P. LPS-10 group: lung (3/3; 100%), spleen (3/3; 100%) and liver (1/3; 33%). At 24 h in the I.P. LPS-20 group, kidney injury was observed in the euthanized mouse. At 96 h in the post-I.N. LPS-20 group, only lung injury was observed in 2/3 (67%) mice (Kruskal-Wallis test with Dunn's, P < 0.01). At 24 h in the post-I.N. LPS-100 group all (4/4) mice had evidence of lung injury. Variable doses of I.N. LPS in mice produced lung injury but did not produce sepsis. Higher doses of I.P. LPS induced multi-organ injury but not respiratory sepsis. Lethal models of respiratory virus, e.g., influenza A, might provide alternative avenues that can be explored in future research.

2.
Pacing Clin Electrophysiol ; 47(4): 568-576, 2024 04.
Article in English | MEDLINE | ID: mdl-38407315

ABSTRACT

BACKGROUND: Clinical studies have demonstrated the safety, efficacy, and efficiency of VISITAG SURPOINT® (VS), which provides important lesion markers during catheter ablation (CA) of atrial fibrillation (AF). The present study evaluated the cost-effectiveness of CA with VS compared to CA without VS in AF from the publicly-funded German and Belgium healthcare perspectives. METHODS: We constructed a two-stage cost utility model that included a decision tree to simulate clinical events, costs, and utilities during the first year after the index procedure and a Markov model to simulate transitions between health states throughout a patient's lifetime. Model inputs included published literature, a meta-analysis of randomized controlled trials AF outcomes, and publicly available administrative data on costs. Deterministic and probabilistic sensitivity analyses were conducted to determine the robustness of the model. RESULTS: CA with VS was associated with lower per patient costs vs CA without VS (Germany: €3295 vs. €3936, Belgium: €3194 vs. €3814) and similar quality-adjusted life-years (QALYs) per patient (Germany: 5.35 vs. 5.34, Belgium: 5.68 vs. 5.67). CA with VS was the dominant ablation strategy (incremental cost-effectiveness ratios: Germany: €-52,455/QALY, Belgium: €-50,676/QALY). The model results were robust and not highly sensitive to variation to individual parameters with regard to QALYs or costs. Freedom from AF and procedure time had the greatest impact on model results, highlighting the importance of these outcomes in ablation. CONCLUSIONS: CA with VS resulted in cost savings and QALY gains compared to CA without VS, supporting the increased adoption of VS in CA in Germany and Belgium.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/surgery , Belgium , Catheter Ablation/methods , Cost-Benefit Analysis , Quality-Adjusted Life Years
SELECTION OF CITATIONS
SEARCH DETAIL