Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 408
1.
World J Urol ; 42(1): 298, 2024 May 06.
Article En | MEDLINE | ID: mdl-38709327

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Equipment Design , Kidney , Lighting , Ureteroscopes , Models, Anatomic , Humans
2.
World J Urol ; 42(1): 310, 2024 May 09.
Article En | MEDLINE | ID: mdl-38722553

INTRODUCTION: Ionizing radiation is used daily during endourological procedures. Despite the dangers of both deterministic and stochastic effects of radiation, there is a lack of knowledge and awareness among urologists. This study reviewed the literature to identify the radiation exposure (RE) of urologists during endourological procedures. METHODS: A literature search of the Medline, Web of Science, and Google Scholar databases was conducted to collect articles related to the radiation dose to urologists during endourological procedures. A total of 1966 articles were screened. 21 publications met the inclusion criteria using the PRIMA standards. RESULTS: Twenty-one studies were included, of which 14 were prospective. There was a large variation in the mean RE to the urologist between studies. PCNL had the highest RE to the urologist, especially in the prone position. RE to the eyes and hands was highest in prone PCNL, compared to supine PCNL. Wearing a thyroid shield and lead apron resulted in a reduction of RE ranging between 94.1 and 100%. Educational courses about the possible dangers of radiation decreased RE and increased awareness among endourologists. CONCLUSIONS: This is the first systematic review in the literature analyzing RE to urologists over a time period of more than four decades. Wearing protective garments such as lead glasses, a thyroid shield, and a lead apron are essential to protect the urologist from radiation. Educational courses on radiation should be encouraged to further reduce RE and increase awareness on the harmful effects of radiation, as the awareness of endourologists is currently very low.


Occupational Exposure , Radiation Exposure , Urologists , Humans , Urology , Urologic Surgical Procedures
3.
World J Urol ; 42(1): 292, 2024 May 04.
Article En | MEDLINE | ID: mdl-38704492

PURPOSE: During endoscopic stone surgery, Holmium:YAG (Ho:YAG) and Thulium Fiber Laser (TFL) technologies allow to pulverize urinary stones into fine particles, ie DUST. Yet, currently there is no consensus on the exact definition of DUST. This review aimed to define stone DUST and Clinically Insignificant Residual Fragments (CIRF). METHODS: Embase, MEDLINE (PubMed) and Cochrane databases were searched for both in vitro and in vivo articles relating to DUST and CIRF definitions, in November 2023, using keyword combinations: "dust", "stones", "urinary calculi", "urolithiasis", "residual fragments", "dusting", "fragments", "lasers" and "clinical insignificant residual fragments". RESULTS: DUST relates to the fine pulverization of urinary stones, defined in vitro as particles spontaneously floating with a sedimentation duration ≥ 2 sec and suited for aspiration through a 3.6Fr-working channel (WC) of a flexible ureteroscope (FURS). Generally, an upper size limit of 250 µm seems to agree with the definition of DUST. Ho:YAG with and without "Moses Technology", TFL and the recent pulsed-Thulium:YAG (pTm:YAG) can produce DUST, but no perioperative technology can currently measure DUST size. The TFL and pTm:YAG achieve better dusting compared to Ho:YAG. CIRF relates to residual fragments (RF) that are not associated with imminent stone-related events: loin pain, acute renal colic, medical or interventional retreatment. CIRF size definition has decreased from older studies based on Shock Wave Lithotripsy (SWL) (≤ 4 mm) to more recent studies based on FURS (≤ 2 mm) and Percutaneous Nephrolithotomy(PCNL) (≤ 4 mm). RF ≤ 2 mm are associated with lower stone recurrence, regrowth and clinical events rates. While CIRF should be evaluated postoperatively using Non-Contrast Computed Tomography(NCCT), there is no consensus on the best diagnostic modality to assess the presence and quantity of DUST. CONCLUSION: DUST and CIRF refer to independent entities. DUST is defined in vitro by a stone particle size criteria of 250 µm, translating clinically as particles able to be fully aspirated through a 3.6Fr-WC without blockage. CIRF relates to ≤ 2 RF on postoperative NCCT.


Ureteroscopy , Urinary Calculi , Humans , Urinary Calculi/therapy , Lithotripsy, Laser/methods , Dust , Particle Size
4.
World J Urol ; 42(1): 294, 2024 May 05.
Article En | MEDLINE | ID: mdl-38704777

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Ureteroscopes , Ureteroscopy , Humans , Equipment Design , Lighting , Pliability , Kidney Calices
5.
World J Urol ; 42(1): 280, 2024 May 01.
Article En | MEDLINE | ID: mdl-38693433

OBJECTIVE: To perform a comprehensive narrative review that will examine the risk factors and treatment outcomes of arterial pseudoaneurysm following laser flexible ureteroscopy (F-URS). METHODS: A retrospective case series and a review of literature was performed. Clinical records from three patients treated for postoperative arterial pseudoaneurysm from January of 2021 to November 2023 were identified. A comprehensive literature review was also performed. The MEDLINE and Scopus databases were searched. The analysis was made by a narrative synthesis. RESULTS: Three cases of postoperative arterial pseudoaneurysm were included, one from our center, one from Dubai, UAE, and one from Barcelona. The literature review identified six case reports, two after endocorporeal laser lithotripsy with thulium fiber laser (TFL) and four with Ho:YAG laser. All cases, from our series and literature review, presented with macroscopic hematuria and used high-power laser settings. All cases were treated by selective embolization. CONCLUSION: Ho:YAG or TFL lasers are both capable of causing arterial pseudoaneurysms following F-URS if high-power settings are used. Selective artery embolization continues to be the treatment of choice with good outcomes.


Aneurysm, False , Lithotripsy, Laser , Aged , Female , Humans , Male , Middle Aged , Aneurysm, False/etiology , Aneurysm, False/therapy , Lithotripsy, Laser/adverse effects , Lithotripsy, Laser/methods , Postoperative Complications/etiology , Retrospective Studies , Ureteroscopy/adverse effects , Adult
6.
BJU Int ; 2024 May 30.
Article En | MEDLINE | ID: mdl-38813615

OBJECTIVE: To perform a collaborative review of the literature exploring the microsatellite instability/deficient mismatch repair (MSI/dMMR) phenotype in patients with upper tract urothelial carcinoma (UTUC). METHOD: A collaborative review of the literature available on Medline was conducted by the Cancer Committee of the French Association of Urology to report studies describing the genetic mechanisms, investigation, prevalence and impact of the MSI/dMMR phenotype in UTUC patients. RESULTS: The predominant genetic mechanism leading to the MSI/dMMR phenotype in UTUC patients is related to the constitutional mutation of one allele of the MMR genes MLH1, MSH2, MSH6 and PMS2 within Lynch syndrome. Indications for its investigation currently remain limited to patients with a clinical suspicion for sporadic UTUC to refer only those with a positive testing for germline DNA sequencing to screen for this syndrome. With regard to technical aspects, despite the interest of MSIsensor, only PCR and immunohistochemistry are routinely used to somatically investigate the MSI and dMMR phenotypes, respectively. The prevalence of the MSI/dMMR phenotype in UTUC patients ranges from 1.7% to 57%, depending on the study population, investigation method and definition of a positive test. Younger age and a more balanced male to female ratio at initial diagnosis are the main specific clinical characteristics of UTUC patients with an MSI/dMMR phenotype. Despite the conflicting results available in the literature, these patients may have a better prognosis, potentially related to more favourable pathological features. Finally, they may also have lower sensitivity to chemotherapy but greater sensitivity to immunotherapy. CONCLUSION: Our collaborative review summarises the available data from published studies exploring the MSI/dMMR phenotype in UTUC patients, the majority of which are limited by a low level of evidence.

7.
Eur Urol Focus ; 2024 May 23.
Article En | MEDLINE | ID: mdl-38789313

BACKGROUND AND OBJECTIVE: The aim of this study was to evaluate the stone-free status (SFS) rate and complications after flexible ureteroscopy (fURS) for treatment of renal stones using a flexible and navigable suction (FANS) ureteral access sheath. METHODS: Data for adults undergoing fURS in 25 centers worldwide were prospectively collected (August 2023 to January 2024). Exclusion criteria were abnormal renal anatomy and ureteral stones. All patients had computed tomography scans before and within 30 d after fURS with a FANS ureteral access sheath. SFS was defined as follows: grade A, zero fragments; grade B, a single fragment ≤2 mm; grade C, a single fragment 2.1-4 mm; and grade D, single/multiple fragments >4 mm. Data for continuous variables are presented as the median and interquartile range (IQR). Multivariable logistic regression was performed to evaluate predictors of grade A SFS. KEY FINDINGS AND LIMITATIONS: The study enrolled 394 patients (59.1% male) with a median age of 49 yr (IQR 36-61). The median stone volume was 1260 mm3 (IQR 706-1800). Thulium fiber laser (TFL) was used in 45.9% of cases and holmium laser in the rest. The median lasing time was 18 min (IQR 11-28) and the median operative time was 49 min (IQR 37-70). One patient required a blood transfusion and 3.3% of patients had low-grade fever. No patient developed sepsis. Low-grade ureteral injury occurred in eight patients (2%). The grade A SFS rate was 57.4% and the grade A + B SFS rate was 97.2%, while 2.8% of patients had grade C or D SFS. Eleven patients underwent repeat fURS. Multivariable analysis revealed that a stone volume of 1501-3000 mm3 (odds ratio 0.50) and of >3000 mm3 (odds ratio 0.29) were significantly associated with lower probability of grade A SFS, while TFL use was associated with higher SFS probability (odds ratio 1.83). Limitations include the lack of a comparative group. CONCLUSIONS AND CLINICAL IMPLICATIONS: fURS using a FANS ureteral access sheath resulted in a high SFS rate with negligible serious adverse event and reintervention rates. PATIENT SUMMARY: We looked at 30-day results for patients undergoing telescopic laser treatment for kidney stones using a special type of vacuum-assisted sheath to remove stone fragments. We found a high stone-free rate with minimal complications.

8.
Turk J Med Sci ; 54(1): 185-193, 2024.
Article En | MEDLINE | ID: mdl-38812627

Background/aim: Management of asymptomatic kidney stones is an ongoing debate with follow-up and treatment guidelines based on low-level evidence. Our aim was to evaluate current management of asymptomatic urinary stones. Materials and methods: A 70-question survey was designed in collaboration with European Association of Urology, Young Academic Urologists, Section of Uro-Technology and Section of Urolithiasis groups and distributed. Responders filled out hypothetical scenarios from 2 perspectives, either as treating physicians, or as patients themselves. Results: A total of 212 (40.01%) responses were obtained. Median responder age was 39 years. 75% of responders were interested in "urolithiasis". 82.5% had never experienced a renal colic, 89.6% had never undergone urolithiasis treatment.Overall, as the kidney stone scenarios got more complicated, the invasiveness of the treatment preference increased. As "the physician", responders preferred the conservative option in all situations more than they would choose as "the patient". For ureteral stones, conservative approach was most preferred for small stones and ureteroscopy became more preferred as the stone size increased.For smaller kidney stones, the most preferred follow-up schedule was 4-6 monthly, whereas for larger and complicated stones it was 0-3 monthly from both perspectives respectively. For all ureteral stone scenarios, 0-4 weekly follow-up was mostly preferred.Interestingly, having had a renal colic was an independent predictor of an interventional approach, whereas having had an intervention was an independent predictor of a conservative approach. Conclusion: Current treatment and follow-up patterns of asymptomatic urinary stones are in agreement with international guidelines on symptomatic stones.In most of the urolithiasis situations urologists chose a conservative approach for their patients compared to what they would prefer for themselves. Conversely, urologists, in the scenarios as "the patient", would like to have a more frequent follow-up schedule for their stones compared to how they would follow-up their patients.


Urologists , Humans , Adult , Surveys and Questionnaires , Male , Female , Urology , Kidney Calculi/therapy , Ureteroscopy , Practice Patterns, Physicians'/statistics & numerical data , Urolithiasis/therapy , Middle Aged , Europe , Attitude of Health Personnel , Asymptomatic Diseases/therapy
9.
Diagnostics (Basel) ; 14(10)2024 May 16.
Article En | MEDLINE | ID: mdl-38786332

The ureteral access sheath (UAS) has been a boon and a bane in flexible ureteroscopy (FURS), with its merits and demerits well established. Its design and dimensions were instrumental in reshaping the way flexible scopes were used and were key adjuncts to establishing retrograde intrarenal surgery (RIRS) as a standard of care in the endourological management of renal stones. With the ever-changing landscape of RIRS over the decades shaped by technological advancements in lasers and flexible scopes, the UAS has also continuously evolved. The utility of suction in endourology has recently changed the way RIRS is performed and is a game changer for FURS outcomes. With strong clinical and experimental evidence to support its use, the UAS has undergone a transformative change in the recent past, with its ability to monitor intrarenal pressure and provide a superior vacuum-cleaner effect that improves the trifecta of RIRS, namely an improved single-stage stone-free rate (SFR), minimise complications, and reduce reinterventions. Our comprehensive review outlines the key clinical and experimental evidence and traces the developments that were key to modifying the traditional UAS into a flexible and navigable suction ureteric access sheath (FANS) and highlights how the design and modifications, in turn, influence the ability to push the boundaries of RIRS.

10.
Fr J Urol ; 34(7-8): 102644, 2024 May 15.
Article En | MEDLINE | ID: mdl-38759842

OBJECTIVES: To characterize and compare in vitro the surfaces of ureteral stents (STENTS) before utilization. METHODS: Our in vitro experiment included six unused STENTS models: three double-pigtail with side orifices (ImaJin and Stenostent [Coloplast©,France], TriaSoft [BostonScientific©,USA]), two double-pigtail without side orifice (Vortek-TumorStent [Coloplast©,France], Urosoft-TumorStent [Bard-Angiomed©,Germany]) and one single-pigtail (J-Fil [Rocamed©,Monaco]). STENTS were made of polyurethane except for ImaJin (silicone). For all STENTS, four parts of the stent were specifically analyzed under high-resolution scanning electron microscopy (HR-SEM,FEI-XL40 [Philips©,France]): surface core, lateral orifice, ureteral loop, and black marking surface. Each experiment was repeated with three different samples from three different stents. STENTS analysis included multiple imperfection searches, defined as irregularities>10µm. RESULTS: All STENTS presented imperfections with no discernible differences. Imperfections were mainly located on the stent loop and on the lateral orifice. For STENTS without side orifice (J-Fil, Urosoft) imperfections were also reported, on the beveled cut as well as the distal loop orifice. Marking surfaces examinations found defects in the Urosoft and imperfections in the ImaJin and Stenostent. The Triasoft presented a better smoothness on marking surfaces compared to other STENTS. Additional matter was reported on the loop distal orifice for J-Fil and ImaJin but all STENTS presented irregular cross-sectional aeras. CONCLUSION: All ureteral stents are not perfectly smooth even before utilization. Imperfections were noticed regardless to stent composition or shape, and could play a role in the incrustation phenomenon, is association with inner irregularities, infection, and urine composition. Both manufacturing and material could have an impact on the stent external surface's smoothness.

11.
World J Urol ; 42(1): 329, 2024 May 16.
Article En | MEDLINE | ID: mdl-38753120

PURPOSE: To define a peak force of insertion (PFOI) threshold for ureteral damage during ureteral access sheath (UAS) placement on an experimental ureteral orifice model. METHODS: A specially designed water tank using 2 laparoscopic 5 mm ports and 2 different size (10 Fr and 8 Fr) sealing cap adaptors (SCA) as ureteral orifices was used to perform the test. A 10-12 Fr UAS was fixed to a load cell and the force of insertion (FOI) was continuously recorded with a digital force gauge.13 experts in the field of endourology who participated performed 3 UAS insertions. The FOI was recorded initially with 10 Fr followed by 8 Fr SCA. On the final insertion, the orifice was obstructed, leaving a 5 cm length to insert the UAS. The experts were asked to "Stop at the point they anticipate ureteral damage, and they would not proceed in real life". RESULTS: Using 10 Fr SCA the PFOI was 2.12 ± 0.58 Newton (N) (range:1.48-3.48) while 8 Fr SCA showed a PFOI 5.76 ± 0.96 N (range:4.05-7.35). Six of the experts, said they would stop proceeding when they reached above 5.1 N. Three experts had PFOI < 5.1 N and the other 4 stated they would go with PFOIs of 5.88, 6.16, 6.69 and 7.35 N when using SCA of 8 Fr.The highest load they would stop proceeding had a PFOI of 6.09 ± 1.87 N (range: 2.53-10.74). CONCLUSION: The PFOI threshold for ureteral damage inserting UAS of the experts is variable. Although FOI is a subjective perception, experience suggests that ureteral injury may occur at an average of 6.05 N perceived by surgeons' tactile feedback. In-vivo measurement of UAS PFOI may confirm a threshold.


Ureter , Ureter/injuries , Humans , Urologic Surgical Procedures/methods , Surgeons
12.
World J Urol ; 42(1): 355, 2024 May 26.
Article En | MEDLINE | ID: mdl-38796790

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Equipment Design , Lighting , Ureteroscopes , Ureteroscopy , Light , Humans , Saline Solution , Color
13.
Int Braz J Urol ; 50(4): 459-469, 2024.
Article En | MEDLINE | ID: mdl-38743064

PURPOSE: To assess the incidence of the most common intra- and early postoperative complications following RIRS in a large series of patients with kidney stones. METHODS: We conducted a retrospective analysis of patients with kidney stones who underwent RIRS across 21 centers from January 2018 to August 2021, as part of the Global Multicenter Flexible Ureteroscopy Outcome (FLEXOR) Registry. RESULTS: Among 6669 patients undergoing RIRS, 4.5% experienced intraoperative pelvicalyceal system bleeding without necessitating blood transfusion. Only 0.1% of patients, required a blood transfusion. The second most frequent intraoperative complication was ureteric injury due to the ureteral access sheath requiring stenting (1.8% of patients). Postoperatively, the most prevalent early complications were fever/infections requiring antibiotics (6.3%), blood transfusions (5.5%), and sepsis necessitating intensive care unit admission (1.3%). In cases of ureteric injury, a notably higher percentage of patients exhibited multiple stones and stone(s) in the lower pole, and these cases were correlated with prolonged lasing and overall surgical time. Hematuria requiring a blood transfusion was associated with an increased prevalence of larger median maximum stone diameters, particularly among patients with stones exceeding 20 mm. Furthermore, these cases exhibited a significant prolongation in surgical time. Sepsis necessitating admission to the intensive care unit was more prevalent among the elderly, concomitant with a significantly larger median maximum stone diameter. CONCLUSIONS: Our analysis showed that RIRS has a good safety profile but bleeding requiring transfusions, ureteric injury, fever, and sepsis are still the most common complications despite advancements in technology.


Kidney Calculi , Postoperative Complications , Registries , Ureteroscopy , Humans , Ureteroscopy/adverse effects , Ureteroscopy/methods , Retrospective Studies , Female , Kidney Calculi/surgery , Male , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Middle Aged , Intraoperative Complications/epidemiology , Intraoperative Complications/etiology , Aged , Adult , Treatment Outcome
14.
World J Urol ; 42(1): 362, 2024 May 30.
Article En | MEDLINE | ID: mdl-38814457

OBJECTIVE: To evaluate long-term surgical and functional outcomes of cystinuric patients exclusively treated with Ureteroscopy (URS). METHODS: Data from patients treated for cystine stones at a single academic center were retrospectively analyzed. The management protocol consisted of (i) treating symptomatic or > 7 mm stones, (ii) multi-staged URS for voluminous stones, (iii) referring patients to a dedicated nephrological clinic. The eGFR was calculated according to the MDRD formula. CKD category was assessed according to the NKF classification. Relevant CKD was defined as CKD category ≥ 3a. Descriptive statistics were used to analyze the cohort data. RESULTS: Data from 46 cystinuric patients treated with 332 URS were available. Median age at diagnosis and at first URS in our center were 18 and 32 years, respectively. Median follow-up was 101 months. Median number of URS and recurrences per patient were 6 and 2, respectively. The median interval between the first and the last available creatinine level was 64 months. Median first and last eGFR were 72 and 74 mL/min, respectively. Overall, 83% of patients had stable or improved renal function within the study period. Ureteral stricture occurred in 3 (6.5%) patients. CONCLUSIONS: Cystinuria requires intensive endoscopic management. Most patients treated with URS have stable or improved renal function within a long-term follow-up. CKD is a not neglectable event that potentially occurs at an early stage of life. Current findings should be considered for the surgical management of cystinuric patients.


Cystinuria , Tertiary Care Centers , Ureteroscopy , Humans , Male , Retrospective Studies , Adult , Female , Adolescent , Cystinuria/complications , Young Adult , Treatment Outcome , Time Factors , Kidney Calculi/surgery , Middle Aged , Child
16.
Eur Urol ; 2024 Apr 20.
Article En | MEDLINE | ID: mdl-38644144

BACKGROUND AND OBJECTIVE: Different training programs have been developed to improve trainee outcomes in urology. However, evidence on the optimal training methodology is sparse. Our aim was to provide a comprehensive description of the training programs available for urological robotic surgery and endourology, assess their validity, and highlight the fundamental elements of future training pathways. METHODS: We systematically reviewed the literature using PubMed/Medline, Embase, and Web of Science databases. The validity of each training model was assessed. The methodological quality of studies on metrics and curricula was graded using the MERSQI scale. The level of evidence (LoE) and level of recommendation for surgical curricula were awarded using the educational Oxford Centre for Evidence-Based Medicine classification. KEY FINDINGS AND LIMITATIONS: A total of 75 studies were identified. Many simulators have been developed to aid trainees in mastering skills required for both robotic and endourology procedures, but only four demonstrated predictive validity. For assessment of trainee proficiency, we identified 18 in robotics training and six in endourology training; however, the majority are Likert-type scales. Although proficiency-based progression (PBP) curricula demonstrated superior outcomes to traditional training in preclinical settings, only four of six (67%) in robotics and three of nine (33%) in endourology are PBP-based. Among these, the Fundamentals of Robotic Surgery and the SIMULATE curricula have the highest LoE (level 1b). The lack of a quantitative synthesis is the main limitation of our study. CONCLUSIONS AND CLINICAL IMPLICATIONS: Training curricula that integrate simulators and PBP methodology have been introduced to standardize trainee outcomes in robotics and endourology. However, evidence regarding their educational impact remains restricted to preclinical studies. Efforts should be made to expand these training programs to different surgical procedures and assess their clinical impact. PATIENT SUMMARY: Simulation-based training and programs in which progression is based on proficiency represent the new standard of quality for achieving surgical proficiency in urology. Studies have demonstrated the educational impact of these approaches. However, there are still no standardized training pathways for several urology procedures.

17.
World J Urol ; 42(1): 233, 2024 Apr 13.
Article En | MEDLINE | ID: mdl-38613608

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Kidney Calculi , Lithotripsy , Ureteral Calculi , Humans , Holmium , Thulium , Ureteroscopy , Prospective Studies , Kidney Calculi/surgery , Lasers
19.
World J Urol ; 42(1): 266, 2024 Apr 27.
Article En | MEDLINE | ID: mdl-38676726

PURPOSE: Considering the existing gaps in the literature regarding patient radiation dose (RD) and its associated risks, a systematic review of the literature on RD was conducted, focusing on percutaneous nephrolithotomy (PCNL), extracorporeal shock wave lithotripsy (SWL), and ureteroscopy (URS). METHODS: Two authors conducted a literature search on PubMed, Web of Science, and Google Scholar to identify studies on RD during endourological procedures. Two thousand two hundred sixty-six articles were screened. Sixty-five publications met the inclusion criteria using the PRISMA standards. RESULTS: RD was generally highest for PCNL, reaching levels up to 33 mSv, 28,700 mGycm2, and 430.8 mGy. This was followed by SWL, with RD reaching up to 7.32 mSv, 13,082 mGycm2, and 142 mGy. URS demonstrated lower RD, reaching up to 6.07 mSv, 8920 mGycm2, and 46.99 mGy. Surgeon experience and case load were inversely associated with RD. Strategies such as optimizing fluoroscopy settings, implementing ultrasound (US), and following the ALARA (As Low As Reasonably Achievable) principle minimized RD. CONCLUSIONS: This is the first systematic review analyzing RD, which was generally highest during PCNL, followed by SWL and URS. There is no specific RD limit for these procedures. Implementation of strategies such as optimizing fluoroscopy settings, utilizing US, and adhering to the ALARA principle proved effective in reducing RD. However, further research is needed to explore the factors influencing RD, assess their impact on patient outcomes, and establish procedure-specific reference levels for RD.


Lithotripsy , Nephrolithotomy, Percutaneous , Radiation Exposure , Ureteroscopy , Humans , Ureteroscopy/adverse effects , Nephrolithotomy, Percutaneous/adverse effects , Nephrolithotomy, Percutaneous/methods , Lithotripsy/adverse effects , Lithotripsy/methods , Radiation Dosage
20.
World J Urol ; 42(1): 188, 2024 Mar 23.
Article En | MEDLINE | ID: mdl-38520528

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Lighting , Ureteroscopes , Humans , Equipment Design , Urologists , Disposable Equipment , Ureteroscopy
...