Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 62
Filter
Add more filters










Publication year range
1.
Biosens Bioelectron ; 255: 116219, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38552525

ABSTRACT

We introduce a versatile method to convert NAD+ or NADP+ -dependent dehydrogenases into quasi-direct electron transfer (quasi-DET)-type dehydrogenases, by modifying with a mediator on the enzyme surface toward the development of 2.5th generation enzymatic sensors. In this study, we use ß-hydroxybutyrate (BHB) dehydrogenase (BHBDh) from Alcaligenes faecalis (AfBHBDh) as a representative NAD+ or NADP+ -dependent dehydrogenase. BHBDhs are important in ketone monitoring, especially for the diagnosis of diabetic ketoacidosis. We modified AfBHBDh with a thiol-reactive phenazine ethosulfate (trPES). We designed, constructed, and modified mutant BHBDhs harboring cysteine residues within 20 Å from the C4 nicotinamide in NAD+/NADH. Mutants Ser65Cys, Thr96Cys, and Lys106Cys showed indistinguishable catalytic activities from the wild-type enzyme, even after trPES modification. These trPES-modified mutants were immobilized on gold disk electrodes via amine coupling with succinimide-groups of dithiobis (succinimidyl hexanoate) self-assembled monolayers for electrochemical measurements. Considering there is a wide range of BHB concentrations, we exploited the linear regression in log scales. The linear range for the sensors with trPES-modified BHBDh mutants Ser65Cys, Thr96Cys, and Lys106Cys were 0.1-4.0 mM in both buffer solution and artificial interstitial fluid (ISF). They have limits of detection of 0.047 mM for Ser65Cys, 0.15 mM for Thr96Cys, and 0.060 mM for Lys106Cys in buffer solution, and 0.12 mM, 0.089 mM, and 0.044 mM in artificial ISF, respectively. These results indicate that redox mediator modification of NAD(P)-dependent dehydrogenases converts them into quasi-DET-type dehydrogenases, thereby enabling their utilization in 2.5th generation enzymatic sensors, which will facilitate the construction of enzymatic sensors suitable for continuous monitoring systems.


Subject(s)
Biosensing Techniques , Glucose , NAD , Electrons , NADP , Biosensing Techniques/methods , Oxidoreductases
2.
Int J Mol Sci ; 25(5)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38474105

ABSTRACT

Although IgG-free immunosensors are in high demand owing to ethical concerns, the development of convenient immunosensors that alternatively integrate recombinantly produced antibody fragments, such as single-chain variable fragments (scFvs), remains challenging. The low affinity of antibody fragments, unlike IgG, caused by monovalent binding to targets often leads to decreased sensitivity. We improved the affinity owing to the bivalent effect by fabricating a bivalent antibody-enzyme complex (AEC) composed of two scFvs and a single glucose dehydrogenase, and developed a rapid and convenient scFv-employed electrochemical detection system for the C-reactive protein (CRP), which is a homopentameric protein biomarker of systemic inflammation. The development of a point-of-care testing (POCT) system is highly desirable; however, no scFv-based CRP-POCT immunosensors have been developed. As expected, the bivalent AEC showed higher affinity than the single scFv and contributed to the high sensitivity of CRP detection. The electrochemical CRP detection using scFv-immobilized magnetic beads and the bivalent AEC as capture and detection antibodies, respectively, was achieved in 20 min without washing steps in human serum and the linear range was 1-10 nM with the limit of detection of 2.9 nM, which has potential to meet the criteria required for POCT application in rapidity, convenience, and hand-held detection devices without employing IgGs.


Subject(s)
Biosensing Techniques , Single-Chain Antibodies , Humans , Single-Chain Antibodies/metabolism , C-Reactive Protein , Immunoassay
3.
J Am Chem Soc ; 146(6): 4087-4097, 2024 02 14.
Article in English | MEDLINE | ID: mdl-38295327

ABSTRACT

DNA-protein complexes are attractive components with broad applications in various research fields, such as DNA aptamer-enzyme complexes as biosensing elements. However, noncovalent DNA-protein complexes often decrease detection sensitivity because they are highly susceptible to environmental conditions. In this study, we developed a versatile DNA-protein covalent-linking patch (D-Pclip) for fabricating covalent and stoichiometric DNA-protein complexes. We comprehensively explored the database to determine the DNA-binding ability of the candidates and selected UdgX as the only uracil-DNA glycosylase known to form covalent bonds with DNA via uracil, with a binding efficiency >90%. We integrated a SpyTag/SpyCatcher protein-coupling system into UdgX to create a universal and convenient D-Pclip. The usability of D-Pclip was shown by preparing a stoichiometric model complex of a hemoglobin (Hb)-binding aptamer and glucose oxidase (GOx) by mixing at 4 °C. The prepared aptamer-GOx complexes detected Hb in a dose-dependent manner within the clinically required detection range in buffer and human serum without any washing procedures. D-Pclip covalently connects any uracil-inserted DNA sequence and any SpyCatcher-fused protein stoichiometrically; therefore, it has a high potential for various applications.


Subject(s)
DNA-Binding Proteins , DNA , Humans , DNA-Binding Proteins/chemistry , DNA/chemistry , Base Sequence , Uracil
4.
Int J Mol Sci ; 24(3)2023 Jan 17.
Article in English | MEDLINE | ID: mdl-36768169

ABSTRACT

The electrochemical enzyme sensors based on direct electron transfer (DET)-type oxidoreductase-based enzymes are ideal for continuous and in vivo monitoring. However, the number and types of DET-type oxidoreductases are limited. The aim of this research is the development of a versatile method to create a DET-type oxidoreductase complex based on the SpyCatcher/SpyTag technique by preparing SpyCatcher-fused heme c and SpyTag-fused non-DET-type oxidoreductases, and by the in vitro formation of DET-type oxidoreductase complexes. A heme c containing an electron transfer protein derived from Rhizobium radiobacter (CYTc) was selected to prepare SpyCatcher-fused heme c. Three non-DET-type oxidoreductases were selected as candidates for the SpyTag-fused enzyme: fungi-derived flavin adenine dinucleotide (FAD)-dependent glucose dehydrogenase (GDH), an engineered FAD-dependent d-amino acid oxidase (DAAOx), and an engineered FMN-dependent l-lactate oxidase (LOx). CYTc-SpyCatcher (CYTc-SC) and SpyTag-Enzymes (ST-GDH, ST-DAAOx, ST-LOx) were prepared as soluble molecules while maintaining their redox properties and catalytic activities, respectively. CYTc-SC/ST-Enzyme complexes were formed by mixing CYTc-SpyCatcher and SpyTag-Enzymes, and the complexes retained their original enzymatic activity. Remarkably, the heme domain served as an electron acceptor from complexed enzymes by intramolecular electron transfer; consequently, all constructed CYTc-SC/ST-Enzyme complexes showed DET ability to the electrode, demonstrating the versatility of this method.


Subject(s)
Electrons , Flavin-Adenine Dinucleotide , Flavin-Adenine Dinucleotide/metabolism , Glucose 1-Dehydrogenase/metabolism , Proteins/metabolism , Oxidation-Reduction
5.
Commun Biol ; 5(1): 1334, 2022 12 06.
Article in English | MEDLINE | ID: mdl-36473944

ABSTRACT

The heterotrimeric flavin adenine dinucleotide dependent glucose dehydrogenase is a promising enzyme for direct electron transfer (DET) principle-based glucose sensors within continuous glucose monitoring systems. We elucidate the structure of the subunit interface of this enzyme by preparing heterotrimer complex protein crystals grown under a space microgravity environment. Based on the proposed structure, we introduce inter-subunit disulfide bonds between the small and electron transfer subunits (5 pairs), as well as the catalytic and the electron transfer subunits (9 pairs). Without compromising the enzyme's catalytic efficiency, a mutant enzyme harboring Pro205Cys in the catalytic subunit, Asp383Cys and Tyr349Cys in the electron transfer subunit, and Lys155Cys in the small subunit, is determined to be the most stable of the variants. The developed engineered enzyme demonstrate a higher catalytic activity and DET ability than the wild type. This mutant retains its full activity below 70 °C as well as after incubation at 75 °C for 15 min - much higher temperatures than the current gold standard enzyme, glucose oxidase, is capable of withstanding.


Subject(s)
Blood Glucose Self-Monitoring , Glucose 1-Dehydrogenase , Electrons , Blood Glucose
6.
Protein Sci ; 31(10): e4434, 2022 10.
Article in English | MEDLINE | ID: mdl-36173159

ABSTRACT

l-Lactate oxidase (LOx) is a flavin mononucleotide (FMN)-dependent triose phosphate isomerase (TIM) barrel fold enzyme that catalyzes the oxidation of l-lactate using oxygen as a primary electron acceptor. Although reductive half-reaction mechanism of LOx has been studied by structure-based kinetic studies, oxidative half-reaction and substrate/product-inhibition mechanisms were yet to be elucidated. In this study, the structure and enzymatic properties of wild-type and mutant LOxs from Enterococcus hirae (EhLOx) were investigated. EhLOx structure showed the common TIM-barrel fold with flexible loop region. Noteworthy observations were that the EhLOx crystal structures prepared by co-crystallization with product, pyruvate, revealed the complex structures with "d-lactate form ligand," which was covalently bonded with a Tyr211 side chain. This observation provided direct evidence to suggest the product-inhibition mode of EhLOx. Moreover, this structure also revealed a flip motion of Met207 side chain, which is located on the flexible loop region as well as Tyr211. Through a saturation mutagenesis study of Met207, one of the mutants Met207Leu showed the drastically decreased oxidase activity but maintained dye-mediated dehydrogenase activity. The structure analysis of EhLOx Met207Leu revealed the absence of flipping in the vicinity of FMN, unlike the wild-type Met207 side chain. Together with the simulation of the oxygen-accessible channel prediction, Met207 may play as an oxygen gatekeeper residue, which contributes oxygen uptake from external enzyme to FMN. Three clades of LOxs are proposed based on the difference of the Met207 position and they have different oxygen migration pathway from external enzyme to active center FMN.


Subject(s)
Enterococcus hirae , Flavin Mononucleotide , Catalytic Domain , Enterococcus hirae/metabolism , Flavin Mononucleotide/chemistry , Kinetics , Lactates , Ligands , Mixed Function Oxygenases/chemistry , Oxygen , Pyruvic Acid , Triose-Phosphate Isomerase/metabolism
7.
Biosens Bioelectron ; 200: 113927, 2022 Mar 15.
Article in English | MEDLINE | ID: mdl-34995837

ABSTRACT

d-Serine biosensing has been extensively reported based on enzyme sensors using flavin adenine dinucleotide (FAD) -dependent d-amino acid oxidase (DAAOx), based on the monitoring of hydrogen peroxide generated by the enzymatic reaction, which is affected by dissolved oxygen concentration in the measurement environment in in vivo use. Here we report a novel sensing principle for d-serine, transient potentiometry based d-serine sensor using engineered DAAOx showing quasi-direct electron transfer (DET) property. DAAOx Gly52Val mutant, revealed to possess dye-mediated dehydrogenase activity using artificial synthetic electron acceptors, while its oxidase activity was negligible. The enzyme was immobilized on electrode and was modified with amine-reactive phenazine ethosulfate, resulted an enzyme electrode showing quasi-DET type response. Although OCP based monitoring took more than several minutes to obtain steady state OCP value, the time dependent OCP change monitoring, transient potentiometry, provided rapid and sensitive sensor signals. While dOCP/dt based monitoring was suitable for sensing with longer than 5 s time resolution with d-serine concentration range between 0.5 mM and 5 mM, dOCP/d t based monitoring is suitable for d-serine monitoring with much shorter time resolution (less than 1 s) with high sensitivity with wider dynamic range (20 µM-30 mM). The maximum dOCP/d t was -39.2 ± 2.0 mV/s1/2, the Km(app) was 1.9 mM, and the lower limit of detection was 20 µM. In addition, d-serine monitoring was also possible in the artificial cerebrospinal fluid. The transient potentiometry based sensing reported in this study will be further utilized to realize miniaturized, continuous, real-time, in vivo sensor for d-serine monitoring.


Subject(s)
Biosensing Techniques , Electrons , Flavin-Adenine Dinucleotide , Glucose , Glucose 1-Dehydrogenase , Potentiometry , Serine
8.
Talanta ; 234: 122638, 2021 Nov 01.
Article in English | MEDLINE | ID: mdl-34364447

ABSTRACT

Human hemoglobin (Hb) is a biomarker of several diseases, and monitoring of Hb levels is required during emergent surgery. However, rapid and sensitive Hb detection methods are yet to be developed. The present study established a rapid, convenient, and highly sensitive detection method for Hb in human serum using a bivalent antibody-enzyme complex (AEC). AECs are promising sensing elements because of their ability to bind specific targets and their catalytic activity that produce signals. We recently reported a convenient and universal method to fabricate bivalent AECs with two antibody fragments, using the SpyCatcher/SpyTag system. The present study applied a bivalent AEC for highly sensitive and quantitative detection of human Hb. The bivalent anti-Hb AEC was successfully prepared by incubating both N- and C-terminus SpyCatcher-fused glucose dehydrogenase and SpyTag-fused anti-Hb single-chain variable fragments at 4 °C. As expected, the bivalent AEC for Hb with a multimeric structure showed higher affinity than the monovalent AEC, by means of avidity effects, unlike that for soluble epidermal growth factor receptor with a monomeric structure; this contributed to a great improvement in sensitivity. Finally, we established a rapid and wash-free homogeneous electrochemical detection system for Hb by integrating magnetic beads. The linear range of the system completely covered the clinically required Hb levels, even in human serum. This technology provides an ideal point-of-care test for Hb and other multimeric biomarkers.


Subject(s)
Single-Chain Antibodies , ErbB Receptors , Hemoglobins , Humans
9.
Molecules ; 26(3)2021 Jan 31.
Article in English | MEDLINE | ID: mdl-33572552

ABSTRACT

Glycated albumin (GA) is an important glycemic control marker for diabetes mellitus. This study aimed to develop a highly sensitive disposable enzyme sensor strip for GA measurement by using an interdigitated electrode (IDE) as an electrode platform. The superior characteristics of IDE were demonstrated using one microelectrode of the IDE pair as the working electrode (WE) and the other as the counter electrode, and by measuring ferrocyanide/ferricyanide redox couple. The oxidation current was immediately reached at the steady state when the oxidation potential was applied to the WE. Then, an IDE enzyme sensor strip for GA measurement was prepared. The measurement of fructosyl lysine, the protease digestion product of GA, exhibited a high, steady current immediately after potential application, revealing the highly reproducible measurement. The sensitivity (2.8 nA µM-1) and the limit of detection (1.2 µM) obtained with IDE enzyme sensor strip were superior compared with our previously reported sensor using screen printed electrode. Two GA samples, 15 or 30% GA, corresponding to healthy and diabetic levels, respectively, were measured after protease digestion with high resolution. This study demonstrated that the application of an IDE will realize the development of highly sensitive disposable-type amperometric enzyme sensors with high reproducibility.


Subject(s)
Biosensing Techniques/instrumentation , Disposable Equipment , Enzymes/metabolism , Serum Albumin/analysis , Electrodes , Glycation End Products, Advanced , Reproducibility of Results , Glycated Serum Albumin
10.
Biosens Bioelectron ; 177: 112984, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-33477030

ABSTRACT

Haemoglobin A1c (hemoglobin A1c, HbA1c) is an important long-term glycemic control marker for diabetes. The aim of this study was to develop an enzyme flow injection analysis (FIA) system using engineered fructosyl peptide oxidase (FPOx) based on 2.5th generation principle for an HbA1c automated analytical system. FPOx from Phaeosphaeria nodorum (PnFPOx) was engineered by introducing a Lys residue at the R414 position, to be modified with amine reactive phenazine ethosulfate (arPES) in proximity of FAD. The engineered PnFPOx mutant with minimized oxidase activity, N56A/R414K, showed quasi-direct electron transfer (quasi-DET) ability after PES-modification. The FIA system was constructed by employing a PES-modified PnFPOx N56A/R414K and operated at 0 V against Ag/AgCl. The system showed reproducible responses with a linear range of 20-500 µM for both fructosyl valine (FV) and fructosyl valylhistidine (FVH), with sensitivities of 0.49 nA µM-1 and 0.13 nA µM-1, and the detection limits of 1.3 µM and 2.0 µM for FV and FVH, respectively. These results indicate that the enzyme electrochemical FIA system covers the clinical range of HbA1c detection for more 200 consecutive measurements. Protease digested three different levels of HbA1c samples including healthy and diabetic range subjects were also measured with the FIA system. Thus, it will be possible to develop an integrated system consisting of sample pretreatment and sample electrochemical measurement based on an FIA system possessing quasi-DET type PnFPOx.


Subject(s)
Biosensing Techniques , Flow Injection Analysis , Ascomycota , Electrons , Glycated Hemoglobin/analysis , Humans , Peptides
11.
Biosens Bioelectron ; 176: 112911, 2021 Mar 15.
Article in English | MEDLINE | ID: mdl-33421758

ABSTRACT

A fusion enzyme composed of an Aspergillus flavus-derived flavin adenine dinucleotide glucose dehydrogenase (AfGDH) and an electron transfer domain of Phanerochaete chrysosporium-derived cellobiose dehydrogenase (Pcyb) was previously reported to show the direct electron transfer (DET) ability to an electrode. However, its slow intramolecular electron transfer (IET) rate from the FAD to the heme, limited the sensor signals. In this study, fusion FADGDH (Pcyb-AfGDH) enzymes were strategically redesigned by performing docking simulation, following surface-electrostatic potential estimation in the predicted area. Based on these predictions, we selected the amino acid substitution on Glu324, or on Asn408 to Lys to increase the positive charge at the rim of the interdomain region. Pcyb-AfGDH mutants were recombinantly produced using Pichia pastoris as the host microorganism, and their IET was evaluated. Spectroscopic observations showed that the Glu324Lys (E324K) and Asn408Lys (N408K) Pcyb-AfGDH mutants showed approximately 1.70- and 9.0-fold faster IET than that of wildtype Pcyb-AfGDH, respectively. Electrochemical evaluation revealed that the mutant Pcyb-AfGDH-immobilized electrodes showed higher DET current values than that of the wildtype Pcyb-AfGDH-immobilized electrodes at pH 6.5, which was approximately 9-fold higher in the E324K mutant and 15-fold higher in the N408K mutant, than in the wildtype. Glucose enzyme sensors employing N408K mutant was able to measure glucose concentration under physiological condition using artificial interstitial fluid at pH 7.4, whereas the one with wildtype Pcyb-AfGDH was not. These results indicated that the sensor employed the redesigned mutant Pcyb-AfGDH can be used for future continuous glucose monitoring system based on direct electron transfer principle. (247 words).


Subject(s)
Biosensing Techniques , Glucose 1-Dehydrogenase , Blood Glucose , Blood Glucose Self-Monitoring , Electron Transport , Electrons , Flavin-Adenine Dinucleotide/metabolism , Glucose , Glucose 1-Dehydrogenase/metabolism , Heme , Saccharomycetales
12.
Biosens Bioelectron ; 176: 112933, 2021 Mar 15.
Article in English | MEDLINE | ID: mdl-33395570

ABSTRACT

The development of wearable multiplexed biosensors has been focused on systems to measure sweat l-lactate and other metabolites, where the employment of the direct electron transfer (DET) principle is expected. In this paper, a fusion enzyme between an engineered l-lactate oxidase derived from Aerococcus viridans, AvLOx A96L/N212K mutant, which is minimized its oxidase activity and b-type cytochrome protein was constructed to realize multiplexed DET-type lactate and glucose sensors. The sensor with a fusion enzyme showed DET to a gold electrode, with a limited operational range less than 0.5 mM. A mutation was introduced into the fusion enzyme to increase Km value and eliminate its substrate inhibition to construct "b2LOxS". Together with the employment of an outer membrane, the detection range of the sensor with b2LOxS was expanded up to 10 mM. A simultaneous lactate and glucose monitoring system was constructed using a flexible thin-film multiplexed electrodes with b2LOxS and a DET-type glucose dehydrogenase, and evaluated their performance in the artificial sweat. The sensors achieved simultaneous detection of lactate and glucose without cross-talking error, with the detected linear ranges of 0.5-20 mM for lactate and 0.1-5 mM for glucose, sensitivities of 4.1 nA/mM∙mm2 for lactate and 56 nA/mM∙mm2 for glucose, and limit of detections of 0.41 mM for lactate and 0.057 mM for glucose. The impact of the presence of electrochemical interferants (ascorbic acid, acetaminophen and uric acid), was revealed to be negligible. This is the first report of the DET-type enzyme based lactate and glucose dual sensing systems.


Subject(s)
Biosensing Techniques , Blood Glucose , Blood Glucose Self-Monitoring , Electrodes , Electrons , Glucose , Glucose Oxidase , L-Lactate Dehydrogenase
13.
Biosens Bioelectron ; 175: 112885, 2021 Mar 01.
Article in English | MEDLINE | ID: mdl-33342691

ABSTRACT

Antibody-enzyme complexes (AECs) with binding ability to specific targets and catalytic activities to gain signals are known to be ideal sensing elements; however, AEC-based universal sensors applicable to point-of-care testing (POCT) have not yet been developed. Here, we achieved rapid and homogeneous electrochemical detection by fabricating a high-affinity bispecific AEC (bsAEC) using two Catcher/Tag systems. Recently, we reported a convenient and universal method to fabricate AECs using the SpyCatcher/SpyTag system. The resultant anti-epidermal growth factor receptor (anti-EGFR) AEC worked efficiently as a sensing element; however, the sensitivities did not meet the clinically required detection range of the soluble ectodomain of EGFR (sEGFR). To induce high affinity even to monomeric targets like sEGFR, we designed a convenient fabrication method for bsAEC using two Catcher/Tag systems, which did not express cross-reactivity. The anti-EGFR bsAEC was successfully prepared by constructing glucose dehydrogenase with two different catcher domains at the N- and C-terminus and by combining two corresponding Tag-fused anti-EGFR single-chain Fvs (scFvs), which recognize different epitopes on sEGFR. As expected, bsAEC showed a higher affinity than that of bivalent AEC with two identical anti-EGFR scFvs at low concentrations of sEGFR, and met the clinically required detection range of sEGFR. Further, by combining magnet beads, we established a rapid and wash-free homogeneous electrochemical detection method. This study offers new insights into the fabrication of universal POCT devices.


Subject(s)
Antibodies, Bispecific , Biosensing Techniques , Single-Chain Antibodies , Epitopes , ErbB Receptors
14.
Biochem Biophys Res Commun ; 530(1): 82-86, 2020 09 10.
Article in English | MEDLINE | ID: mdl-32828319

ABSTRACT

Fungi-derived flavin adenine dinucleotide (FAD)-dependent glucose dehydrogenases (FADGDHs) are the most popular and advanced enzymes for SMBG sensors because of their high substrate specificity toward glucose and oxygen insensitivity. However, this type of FADGDH hardly shows direct electron transfer (DET) ability. In this study, we developed a new DET-type FADGDH by harboring Cytochrome b562 (cyt b562) derived from Escherichia coli as the electron transfer domain. The structural genes encoding fusion enzymes composed of cyt b562 at either the N- or C-terminus of fungal FADGDH, (cyt b562-GDH or GDH-cyt b562), were constructed, recombinantly expressed, and characteristics of the fusion proteins were investigated. Both constructed fusion enzymes were successfully expressed in E. coli, as the soluble and GDH active proteins, showing cyt b562 specific redox properties. Thusconstructed fusion proteins showed internal electron transfer between FAD in FADGDH and fused cyt b562. Consequently, both cyt b562-GDH and GDH-cyt b562 showed DET abilities toward electrode. Interestingly, cyt b562-GDH showed much rapid internal electron transfer and higher DET ability than GDH-cyt b562. Thus, we demonstrated the construction and production of a new DET-type FADGDH using E.coli as the host cells, which is advantageous for future industrial application and further engineering.


Subject(s)
Botrytis/genetics , Cytochrome b Group/genetics , Escherichia coli Proteins/genetics , Escherichia coli/genetics , Glucose 1-Dehydrogenase/genetics , Botrytis/metabolism , Cytochrome b Group/metabolism , Electron Transport , Escherichia coli/metabolism , Escherichia coli Proteins/metabolism , Flavin-Adenine Dinucleotide/metabolism , Glucose 1-Dehydrogenase/metabolism , Protein Engineering , Recombinant Fusion Proteins/genetics , Recombinant Fusion Proteins/metabolism , Substrate Specificity
15.
Sensors (Basel) ; 20(10)2020 May 15.
Article in English | MEDLINE | ID: mdl-32429321

ABSTRACT

In this paper, a novel electron mediator, 1-methoxy-5-ethyl phenazinium ethyl sulfate (mPES), was introduced as a versatile mediator for disposable enzyme sensor strips, employing representative flavin oxidoreductases, lactate oxidase (LOx), glucose dehydrogenase (GDH), and fructosyl peptide oxidase (FPOx). A disposable lactate enzyme sensor with oxygen insensitive Aerococcus viridans-derived engineered LOx (AvLOx), with A96L mutant as the enzyme, was constructed. The constructed lactate sensor exhibited a high sensitivity (0.73 ± 0.12 µA/mM) and wide linear range (0-50 mM lactate), showings that mPES functions as an effective mediator for AvLOx. Employing mPES as mediator allowed this amperometric lactate sensor to be operated at a relatively low potential of +0.2 V to 0 V vs. Ag/AgCl, thus avoiding interference from uric acid and acetaminophen. The lactate sensors were adequately stable for at least 48 days of storage at 25 °C. These results indicated that mPES can be replaced with 1-methoxy-5-methyl phenazinium methyl sulfate (mPMS), which we previously reported as the best mediator for AvLOx-based lactate sensors. Furthermore, this study revealed that mPES can be used as an effective electron mediator for the enzyme sensors employing representative flavin oxidoreductases, GDH-based glucose sensors, and FPOx-based hemoglobin A1c (HbA1c) sensors.


Subject(s)
Aerococcus/enzymology , Amino Acid Oxidoreductases/chemistry , Biosensing Techniques , Electrons , Glucose Dehydrogenases/chemistry , Mixed Function Oxygenases/chemistry , Sulfuric Acid Esters/chemistry
16.
Int J Mol Sci ; 21(11)2020 May 27.
Article in English | MEDLINE | ID: mdl-32471202

ABSTRACT

In this review, recent progress in the engineering of the oxidative half-reaction of flavin-dependent oxidases and dehydrogenases is discussed, considering their current and future applications in bioelectrochemical studies, such as for the development of biosensors and biofuel cells. There have been two approaches in the studies of oxidative half-reaction: engineering of the oxidative half-reaction with oxygen, and engineering of the preference for artificial electron acceptors. The challenges for engineering oxidative half-reactions with oxygen are further categorized into the following approaches: (1) mutation to the putative residues that compose the cavity where oxygen may be located, (2) investigation of the vicinities where the reaction with oxygen may take place, and (3) investigation of possible oxygen access routes to the isoalloxazine ring. Among these approaches, introducing a mutation at the oxygen access route to the isoalloxazine ring represents the most versatile and effective strategy. Studies to engineer the preference of artificial electron acceptors are categorized into three different approaches: (1) engineering of the charge at the residues around the substrate entrance, (2) engineering of a cavity in the vicinity of flavin, and (3) decreasing the glycosylation degree of enzymes. Among these approaches, altering the charge in the vicinity where the electron acceptor may be accessed will be most relevant.


Subject(s)
Electron Transport , Flavoproteins/chemistry , Oxidoreductases/chemistry , Animals , Flavins/chemistry , Flavins/metabolism , Flavoproteins/metabolism , Humans , Oxidoreductases/metabolism , Oxygen/chemistry , Oxygen/metabolism
17.
Int J Mol Sci ; 21(3)2020 Feb 08.
Article in English | MEDLINE | ID: mdl-32046321

ABSTRACT

Glucose oxidase (GOx) has been widely utilized for monitoring glycemic levels due to its availability, high activity, and specificity toward glucose. Among the three generations of electrochemical glucose sensor principles, direct electron transfer (DET)-based third-generation sensors are considered the ideal principle since the measurements can be carried out in the absence of a free redox mediator in the solution without the impact of oxygen and at a low enough potential for amperometric measurement to avoid the effect of electrochemically active interferences. However, natural GOx is not capable of DET. Therefore, a simple and rapid strategy to create DET-capable GOx is desired. In this study, we designed engineered GOx, which was made readily available for single-step modification with a redox mediator (phenazine ethosulfate, PES) on its surface via a lysine residue rationally introduced into the enzyme. Thus, PES-modified engineered GOx showed a quasi-DET response upon the addition of glucose. This strategy and the obtained results will contribute to the further development of quasi-DET GOx-based glucose monitoring dedicated to precise and accurate glycemic control for diabetic patient care.


Subject(s)
Biosensing Techniques/methods , Blood Glucose/analysis , Glucose Oxidase/metabolism , Phenazines/metabolism , Protein Engineering , Aspergillus niger/enzymology , Electrochemical Techniques , Fungal Proteins/metabolism , Glucose/metabolism , Glucose Oxidase/genetics
18.
Biosens Bioelectron ; 151: 111974, 2020 Mar 01.
Article in English | MEDLINE | ID: mdl-31999581

ABSTRACT

The l-lactate oxidase (LOx) based lactate sensors are widely used for clinical diagnostics, sports medicine, and food quality control. However, dissolved oxygen interference and electroactive interferent effects are inherent issues of current lactate sensors. In this paper, a quasi-direct electron transfer (quasi-DET) type lactate sensor was developed using rationally engineered Aerococcus viridans LOx (AvLOx) modified with amine-reactive phenazine ethosulfate (PES). Since the modification of wild type AvLOx by PES did not result quasi-DET, engineered AvLOx with additional Lys residue was designed. The additional Lys residue was introduced by substituting residue locating on the surface of AvLOx, and within 20 Šof the isoalloxazine ring of FMN. Among several constructed mutants, Ala96Leu/Asn212Lys double mutant showed the highest dye-mediated dehydrogenase activity with negligible oxidase activity, showing quasi-DET properties after PES modification, when the enzyme was immobilized on screen printed carbon electrode. The constructed electrode did not show oxygen interference in cyclic voltammetric analysis and distinct catalytic current with 20 mM l-lactate. The sensor performance of a chronoamperometric l-lactate sensor employing PES modified Ala96Leu/Asn212Lys AvLOx, marked with linear range between 0 and 1 mM, with sensitivity of 13 µA/mM∙cm2, and a limit of detection of 25 µM for l-lactate. By applying -200 mV vs. Ag/AgCl, l-lactate could be monitored with negligible interference from 170 µM ascorbic acid, 1.3 mM acetaminophen, 1.4 mM uric acid or 20 mM glucose. These results indicated that a quasi-DET type lactate sensor was developed that did not suffer from the interference of oxygen and representative electroactive ingredient compounds.


Subject(s)
Aerococcus/isolation & purification , Biosensing Techniques , Lactic Acid/isolation & purification , Mixed Function Oxygenases/chemistry , Aerococcus/chemistry , Catalysis , Enzymes, Immobilized/chemistry , Glucose/chemistry , Humans , Lactic Acid/chemistry , Oxidation-Reduction
19.
Acta Crystallogr D Struct Biol ; 75(Pt 9): 841-851, 2019 Sep 01.
Article in English | MEDLINE | ID: mdl-31478907

ABSTRACT

The bacterial flavin adenine dinucleotide (FAD)-dependent glucose dehydrogenase complex derived from Burkholderia cepacia (BcGDH) is a representative molecule of direct electron transfer-type FAD-dependent dehydrogenase complexes. In this study, the X-ray structure of BcGDHγα, the catalytic subunit (α-subunit) of BcGDH complexed with a hitchhiker protein (γ-subunit), was determined. The most prominent feature of this enzyme is the presence of the 3Fe-4S cluster, which is located at the surface of the catalytic subunit and functions in intramolecular and intermolecular electron transfer from FAD to the electron-transfer subunit. The structure of the complex revealed that these two molecules are connected through disulfide bonds and hydrophobic interactions, and that the formation of disulfide bonds is required to stabilize the catalytic subunit. The structure of the complex revealed the putative position of the electron-transfer subunit. A comparison of the structures of BcGDHγα and membrane-bound fumarate reductases suggested that the whole BcGDH complex, which also includes the membrane-bound ß-subunit containing three heme c moieties, may form a similar overall structure to fumarate reductases, thus accomplishing effective electron transfer.


Subject(s)
Burkholderia cepacia/enzymology , Glucose Dehydrogenases/chemistry , Catalytic Domain , Crystallography, X-Ray/methods , Electron Transport , Flavin-Adenine Dinucleotide/chemistry , Models, Molecular , Recombinant Proteins/chemistry
20.
Nucleic Acid Ther ; 29(4): 224-229, 2019 08.
Article in English | MEDLINE | ID: mdl-30835633

ABSTRACT

Single-strand oligodeoxynucleotides (ODNs) containing unmethylated cytosine-phosphate-guanine (CpG) are recognized by the toll-like receptor 9, a component of the innate immunity. Therefore, they could act as immunotherapeutic agents. Chemically modified CpG ODNs containing a phosphorothioate backbone instead of phosphodiester (PD) were developed as immunotherapeutic agents resistant to nuclease degradation. However, they cause adverse side effects, and so there is a necessity to generate novel CpG ODNs. In the present study, we designed a nuclease-resistant nonmodified CpG ODN that forms G-quadruplex structures. G-quadruplex formation in CpG ODNs increased nuclease resistance and cellular uptake. The CpG ODNs designed in this study induced interleukin-6 production in a human B lymphocyte cell line and human peripheral blood mononuclear cells. These results indicate that G-quadruplex formation can be used to increase the immunostimulatory activity of CpG ODNs having a natural PD backbone.


Subject(s)
G-Quadruplexes , Leukocytes, Mononuclear/immunology , Oligonucleotides, Antisense/genetics , Adjuvants, Immunologic/genetics , Adjuvants, Immunologic/pharmacology , Animals , Cell Line , CpG Islands/drug effects , Humans , Immunologic Factors/genetics , Leukocytes, Mononuclear/drug effects , Nucleic Acid Conformation/drug effects , Oligonucleotides, Antisense/chemistry , Phosphates/chemistry , Phosphates/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL