Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Innov Card Rhythm Manag ; 15(7): 5930-5934, 2024 Jul.
Article in English | MEDLINE | ID: mdl-39011464

ABSTRACT

With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system. This case demonstrates the utility of a temporary externalized transvenous ICD system in the successful detection and pace-termination of VT, thereby reducing episodes of painful and potentially harmful external defibrillator shocks during the treatment of CIED infection.

2.
Heart Rhythm ; 2024 May 06.
Article in English | MEDLINE | ID: mdl-38718942

ABSTRACT

BACKGROUND: Myocardial electrical heterogeneity is critical for normal cardiac electromechanical function, but abnormal or excessive electrical heterogeneity is proarrhythmic. The spatial ventricular gradient (SVG), a vectorcardiographic measure of electrical heterogeneity, has been associated with arrhythmic events during long-term follow-up, but its relationship with short-term inducibility of ventricular arrhythmias (VAs) is unclear. OBJECTIVE: This study was designed to determine associations between SVG and inducible VAs during electrophysiology study. METHODS: A retrospective study was conducted of adults without prior sustained VA, cardiac arrest, or implantable cardioverter-defibrillator who underwent ventricular stimulation for evaluation of syncope and nonsustained ventricular tachycardia or for risk stratification before primary prevention implantable cardioverter-defibrillator implantation. The 12-lead electrocardiograms were converted into vectorcardiograms, and SVG magnitude (SVGmag) and direction (azimuth and elevation) were calculated. Odds of inducible VA were regressed by logistic models. RESULTS: Of 143 patients (median age, 69 years; 80% male; median left ventricular ejection fraction [LVEF], 47%; 52% myocardial infarction), 34 (23.8%) had inducible VAs. Inducible patients had lower median LVEF (38% vs 50%; P < .0001), smaller SVGmag (29.5 vs 39.4 mV·ms; P = .0099), and smaller cosine SVG azimuth (cosSVGaz; 0.64 vs 0.89; P = .0007). When LVEF, SVGmag, and cosSVGaz were dichotomized at their medians, there was a 39-fold increase in adjusted odds (P = .002) between patients with all low LVEF, SVGmag, and cosSVGaz (65% inducible) compared with patients with all high LVEF, SVGmag, and cosSVGaz (4% [n = 1] inducible). After multivariable adjustment, SVGmag, cosSVGaz, and sex but not LVEF or other characteristics remained associated with inducible VAs. CONCLUSION: Assessment of electrical heterogeneity by SVG, which reflects abnormal electrophysiologic substrate, adds to LVEF and identifies patients at high and low risk of inducible VA at electrophysiology study.

SELECTION OF CITATIONS
SEARCH DETAIL