Talanta ; 203: 161-167, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31202322

ABSTRACT

A simple and rapid impedimetric sensor applicable for industrial lipase activity quantification was developed and characterized. It is based on the lipase catalyzed degradation by hydrolysis of a thin nanocomposite substrate sensitive layer deposited on a PCB stick electrode usable as disposable or regenerable. The sensitive layer degradation rate was evaluated by the impedance changes registration along time resulting from its thickness diminution applying a small amplitude AC voltage with a constant frequency. The AC current phase shift variations along the time caused by the impedance changes were registered as s sensor response. The sensor was characterized in terms of linear quantification range, LOD, precision and quantification time. The response time was found to be from 80 to 6 s for the linear concentration range from 0.99x10-2 to 1.68 U.S.P. U mL-1 with relative errors from 3.75% to 1.24% respectively and a LOD of 8x10-3 U.S.P. U mL-1. Finally, lipase spiked whey samples taken from milk industry were quantified and the results were validated by a titrimetric method revealing a good agreement (relative error less than 4.5%).


Subject(s)
Lipase/analysis , Electric Impedance , Electrochemical Techniques/instrumentation , Electrochemical Techniques/methods , Electrodes , Equipment Design , Limit of Detection , Metal Nanoparticles/chemistry , Nanocomposites/chemistry , Olive Oil/chemistry , Oxides/chemistry , Silicon Dioxide/chemistry , Silver Compounds/chemistry
2.
Sensors (Basel) ; 19(10)2019 May 17.
Article in English | MEDLINE | ID: mdl-31108833

ABSTRACT

Selective UV sensitivity was observed in Metal-Oxide-Semiconductor structures with Si nanoclusters. Si nanocrystals and amorphous Si nanoparticles (a-Si NPs) were obtained by furnace annealing of SiOx films with x = 1.15 for 60 min in N2 at 1000 and 700 °C, respectively. XPS and TEM analysis prove phase separation and formation of Si nanocrystals in SiO2, while the a-Si NPs are formed in SiO1.7 matrix. Both types of structures show selective sensitivity to UV light; the effect is more pronounced in the structure with nanocrystals. The responsivity of the nanocrystal structure to 365 nm UV light is ~ 4 times higher than that to green light at 4 V applied to the top contact. The observed effect is explained by assuming that only short wavelength radiation generates photocarriers in the amorphous and crystalline nanoclusters.

3.
Talanta ; 179: 594-600, 2018 Mar 01.
Article in English | MEDLINE | ID: mdl-29310281

ABSTRACT

A simple and rapid reagent less nephelometric method for on-line H2O2 quantification in semiconductors etching solutions was developed, optimized, characterized and validated. The intensity of the light scattered by the oxygen gas suspension resulted from H2O2 catalytic decomposition by immobilized MnO2 was registered as analytical response. The influences of the light wave length, the agitation rate, the temperature and the catalyst surface area on the response amplitude were studied and optimization was done. The achieved linear concentration range from 10 to 150mmolL-1 at 0.9835 calibration curve correlation coefficient, precision from 3.65% to 0.95% and response time from 35 to 20s respectively, at sensitivity of 8.01µAmmol-1 L and LOD of 2.9mmolL -1 completely satisfy the semiconductor industry requirements.

4.
Talanta ; 171: 39-44, 2017 Aug 15.
Article in English | MEDLINE | ID: mdl-28551151

ABSTRACT

A simple, rapid, and reagent-less calorimetric method for H2O2 quantification, applicable automatically on-line was developed, analytically characterized and tested with real SC-1 alkaline etching solutions used in the semiconductor technology. Being based on H2O2 catalytic decomposition by immobilized solid catalyst, the proposed method possesses excellent specificity toward the H2O2 without any interference. The total quantification time was found to be less than 60s, RSD lies in the range from 4.7% to 1.8% for the linear concentration range from 2.8 10-2 to 2molL-1 respectively and the LOD was determined to be as low as 9.3 10-3molL-1.

5.
J Anal Methods Chem ; 2013: 193230, 2013.
Article in English | MEDLINE | ID: mdl-23691434

ABSTRACT

A virtual instrumentation (VI) system called VI localized corrosion image analyzer (LCIA) based on LabVIEW 2010 was developed allowing rapid automatic and subjective error-free determination of the pits number on large sized corroded specimens. The VI LCIA controls synchronously the digital microscope image taking and its analysis, finally resulting in a map file containing the coordinates of the detected probable pits containing zones on the investigated specimen. The pits area, traverse length, and density are also determined by the VI using binary large objects (blobs) analysis. The resulting map file can be used further by a scanning vibrating electrode technique (SVET) system for rapid (one pass) "true/false" SVET check of the probable zones only passing through the pit's centers avoiding thus the entire specimen scan. A complete SVET scan over the already proved "true" zones could determine the corrosion rate in any of the zones.

6.
Contraception ; 81(3): 261-4, 2010 Mar.
Article in English | MEDLINE | ID: mdl-20159185

ABSTRACT

BACKGROUND: Female pelvic actinomycosis may involve fallopian tubes, ovaries, uterus and bladder. This condition is often associated with the use of intrauterine contraceptive devices (IUDs), vaginal pessaries and/or tampons. The predominant causative agent of human actinomycosis is Actinomyces israelii, which has been found on copper IUDs retrieved from patients. STUDY DESIGN: In this work, a biofilm of A. israelii was developed in vitro on copper surfaces immersed in a simulated uterine fluid under anaerobic conditions. The biofilm was characterized using scanning electron microscopy (SEM), energy dispersive X-ray and atomic force microscopy. RESULTS: The capacity of A. israelii to develop a biofilm over copper surfaces in synthetic media was demonstrated. SEM micrographies illustrate the exopolysaccharides production and bacterial distribution. CONCLUSION: A. israelii was able to attach and grow in synthetic intrauterine media and to present on the copper surface is likely due to the production of biofilm.


Subject(s)
Actinomyces/growth & development , Biofilms/growth & development , Intrauterine Devices, Copper/microbiology , Actinomycosis/microbiology , Equipment Contamination , Female , Humans , Microscopy, Electron, Scanning , Prosthesis-Related Infections/microbiology
7.
Biosens Bioelectron ; 25(2): 482-7, 2009 Oct 15.
Article in English | MEDLINE | ID: mdl-19729293

ABSTRACT

A novel electrochemical biosensor integrating the strictly autotrophic bacterial strain Leptospirillum ferrooxidans as a recognition element and a Clark type oxygen probe as a transducer was designed, metrologically and analytically characterized and applied for the specific Fe(2+) determination. The bacterial Fe(2+) oxidation involves O(2) consumption, thus the quantification was performed registering the decrease of the oxygen reduction current. The limit of detection was found to be 2.4 micromol L(-1) and the sensitivity of the determinations-3.94 nAL micromol(-1). The response time of the biosensor is 18s for Fe(2+) concentrations of 10(-5) to 10(-4) mol L(-1). The biosensor was applied as well for the indirect determination of Fe(2+) oxidizing species such as Cr(2)O(7)(2-), reaching a sensitivity of 2.47 nAL micromol(-1). The transducer characteristics were evaluated and optimized to obtain short response time and high sensitivity. The analytical performances of the biosensor subject of the present work were found to be similar to that of the At. ferrooxidans based one developed by the authors earlier, avoiding however the sulfur compounds interference, because of the substrate specificity of the applied bacterial strain.


Subject(s)
Biological Assay/instrumentation , Biosensing Techniques/instrumentation , Iron/analysis , Iron/pharmacology , Leptospira/drug effects , Leptospira/physiology , Oxygen Consumption/physiology , Electrochemistry/instrumentation , Equipment Design , Equipment Failure Analysis , Transducers
8.
Biosens Bioelectron ; 22(1): 1-9, 2006 Jul 15.
Article in English | MEDLINE | ID: mdl-16376069

ABSTRACT

The sensors applied recently for determination of cholinesterase activity are mostly enzymatic amperometric sensors, in spite of their disadvantages: short life-time at ambient temperature, instability of the response, interferences, as well as passivation of the electrode surface. In the present paper a new approach for determination of cholinesterase activity was proposed, overcoming the main drawbacks of the analysis performed with amperometric enzymatic sensors. Instead of the immobilization of enzymes on a conducting electrode surface, whole cells of Arthrobacter globiformis, containing choline oxidase were fixed on a Clark type oxygen probe. Current proportional to bacteria respiration is registered as a sensor response. The application of whole cells of bacteria as a sensing element permits to achieve high stability of the response and long life-time of the sensor at ambient temperature, due to the conservation of the enzyme in its natural micro-environment inside the immobilized cells. The proposed sensor keeps its functionality more than 7 weeks stored in deionized water at ambient temperature. For the first 2 weeks the amplitude of the response decreases with only 10% and at the end of the studied 7 weeks period the response was 50% of the initial. The other advantages of the proposed sensor are: the dissolved oxygen is used as a mediator which concentration can be reliably and interferences free measured by the aim of a Clark type oxygen probe applied as a transducer; reproducible bacterial membranes can be elaborated by filtration of resuspended bacterial culture after preliminary determination of its activity; application of membranes containing lyophilized bacteria capable to be conserved infinitely long time and activated just before their application; negligible cost compared with the sensors based on immobilized enzymes. The steady-state response of the proposed bacterial sensor to choline obtained in 200 s is linear in the investigated concentration range up to 2 x 10(-4) moldm(-3), with detection limit of 8 x 10(-8) moldm(-3) and sensitivity of 4 x 10(-1) microAcm(3)mol(-1), at pH 6, temperature of 25 degrees C and stirring rate of 300 rpm. Choline is formed as a result of the catalytic hydrolysis (depending on the cholinesterase activity) of the substrate acetylcholine. Linear calibration graph for cholinesterase activity determination was obtained in the range up to 11 mUcm(-3), with a slope of 1.97 x 10(-2) microAcm(3)mU(-1), at pH 6, temperature of 25 degrees C and stirring rate of 300 rpm. The tests with reconstituted lyophilized serum with known activity used as a control sample confirm the accuracy of the proposed method. The relative error of the determination was only 2.82%.


Subject(s)
Arthrobacter , Biosensing Techniques , Cholinesterases/analysis , Electrochemistry , Choline