Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 539
Filter
1.
Am J Cardiol ; 2024 Sep 04.
Article in English | MEDLINE | ID: mdl-39241974

ABSTRACT

An increased total stent length (TSL) might be associated with a higher risk of clinical events, however, in patients with multivessel disease (MVD) a considerable total stent length is often required. In patients presenting with acute coronary syndrome (ACS) and MVD, immediate complete revascularization was associated with shorter TSL in the BIOVASC Trial. This is a sub-analysis of the BIOVASC trial comparing clinical outcomes in patients with either <60mm or ≥60mm total stent length. The primary outcome was a composite of all-cause mortality, myocardial infarction, any unplanned ischemia driven revascularization or cerebrovascular events at 2 years post index procedure. 1525 patients were enrolled in the BIOVASC trial, of whom 855 had a TSL of ≥60mm (long TSL). No significant difference was established when comparing patients treated with either long or short TSL in terms of the primary outcome at 2-year follow up, which occurred in 117 patients (13.7%) in the ≥60 mm group and 69 patients (10.3%) in the <60mm group (adjusted HR 1.25, 95% CI 0.92-1.69, p=0.16). Also, no significant differences were observed in the secondary endpoints. In conclusion, in patients with ACS and MVD, long stenting did not show a significant difference in clinical event rate compared with short stenting.

2.
Am Heart J Plus ; 46: 100451, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39296913

ABSTRACT

Insights in age- and sex-specific coronary atherosclerotic plaque characteristics may contribute to a better understanding of coronary artery disease and, ultimately, to its prevention and treatment. In 307 women and 406 men aged 20 to 90 years undergoing intravascular ultrasound imaging, sex-based differences in coronary atherosclerotic plaque characteristics were mainly present in younger patients, while these differences were less pronounced at advanced age.

3.
Neth Heart J ; 2024 Sep 16.
Article in English | MEDLINE | ID: mdl-39283568

ABSTRACT

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has emerged as a minimally invasive alternative to mitral valve surgery for patients at high or prohibitive operative risk. Prospective studies reported favourable outcomes in patients with annulus calcification (valve-in-mitral annulus calcification; ViMAC), failed annuloplasty ring (mitral valve-in-ring; MViR), and bioprosthetic mitral valve dysfunction (mitral valve-in-valve; MViV). Multi-slice computed tomography (MSCT)-derived 3D-modelling and simulations may provide complementary anatomical perspectives for TMVR planning. AIMS: We aimed to illustrate the implementation of MSCT-derived modelling and simulations in the workup of TMVR for ViMAC, MViR, and MViV. METHODS: For this retrospective study, we included all consecutive patients screened for TMVR and compared MSCT data, echocardiographic outcomes and clinical outcomes. RESULTS: Sixteen out of 41 patients were treated with TMVR (ViMAC n = 9, MViR n = 3, MViV n = 4). Eleven patients were excluded for inappropriate sizing, 4 for anchoring issues and 10 for an unacceptable risk of left ventricular outflow tract obstruction (LVOTO) based on 3D modelling. There were 3 procedure-related deaths and 1 non-procedure-related cardiovascular death during 30 days of follow-up. LVOTO occurred in 3 ViMAC patients and 1 MViR patient, due to deeper valve implantation than planned in 3 patients, and anterior mitral leaflet displacement with recurrent basal septum thickening in 1 patient. TMVR significantly reduced mitral mean gradients as compared with baseline measurements (median mean gradient 9.5 (9.0-11.5) mm Hg before TMVR versus 5.0 (4.5-6.0) mm Hg after TMVR, p = 0.03). There was no residual mitral regurgitation at 30 days. CONCLUSION: MSCT-derived 3D modelling and simulation provide valuable anatomical insights for TMVR with transcatheter balloon expandable valves in ViMAC, MViR and MViV. Further planning iterations should target the persistent risk for neo-LVOTO.

4.
Struct Heart ; 8(5): 100279, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39290682

ABSTRACT

Moderate aortic stenosis is increasingly recognized as a disease entity with poor prognosis. Diagnosis of moderate aortic stenosis may be complemented by laboratory tests and advanced imaging techniques focused at detecting signs of cardiac damage such as increase of cardiac enzymes (N-terminal pro-B-type Natriuretic Peptide, troponin), left ventricular remodeling (hypertrophy, reduced left ventricular ejection fraction), or myocardial fibrosis. Therapy should include guideline-directed optimal medical therapy for heart failure. Patients with signs of cardiac damage may benefit from early intervention, which is the focus of several ongoing randomized controlled trials. As yet, no evidence-based therapy exists to halt the progression of aortic valve calcification.

6.
Article in English | MEDLINE | ID: mdl-39192480

ABSTRACT

AIMS: There is a paucity of data on the performance of angiography-derived vessel fractional flow reserve (vFFR) in coronary artery lesions of patients presenting with non-ST-segment elevation acute coronary syndrome (NSTE-ACS). Optical coherence tomography (OCT) allows for visualization of lumen dimensions and plaque integrity with high resolution. The aim of the present study was to define the association between vFFR and OCT findings in intermediate coronary artery lesions in patients presenting with NSTE-ACS. METHODS AND RESULTS: The FAST OCT study was a prospective, multicenter, single-arm study. Patients presenting with NSTE-ACS with intermediate to severe coronary artery stenosis in one or multiple vessels with TIMI 3 flow suitable for OCT imaging were eligible. Complete pre-procedural vFFR and OCT data were available in 226 vessels (in 188 patients). A significant association between vFFR and minimal lumen area (MLA) was observed, showing an average decrease of 20.4% (95% CI -23.9% - -16.7%) in MLA per 0.10 decrease in vFFR (adjusted p<0.001). vFFR≤0.80 showed a sensitivity of 56.7% and specificity of 92.5% to detect MLA≤2.5 mm². Conversely, vFFR had a poor to moderate discriminative ability to detect plaque instability (sensitivity, 46.9% specificity 71.6%). CONCLUSIONS: In patients with NSTE-ACS, vFFR is significantly associated with OCT-detected MLA and a vFFR≤0.80 is highly predictive for the presence of significant disease based on OCT. Conversely, the sensitivity of vFFR≤0.80 to detect OCT-assessed significant disease was low, indicating that the presence of significant OCT findings cannot be ruled out based on a negative vFFR. CLINICALTRIALS.GOV ID: NCT04683133.

7.
Article in English | MEDLINE | ID: mdl-39193828

ABSTRACT

BACKGROUND: Paravalvular leakage (PVL) and conduction disorders that require permanent pacemaker implantation (PPI) remain clinically relevant challenges after transcatheter aortic valve implantation (TAVI). Computed tomography-based simulations may predict the risk of significant PVL and PPI. AIMS: To evaluate the feasibility and accuracy of preprocedural computer simulation with FEops HEARTguide™ to predict >trace PVL and PPI after TAVI with the self-expanding supra-annular ACURATE Neo2 transcatheter heart valve. METHODS: Prospective multicenter observational study that included consecutive patients undergoing TAVI with an ACURATE Neo2 valve. Computer simulations were performed before the TAVI procedure as part of the preprocedural planning. Follow-up period for PPI and PVL was 30 days. RESULTS: Sixty-five patients were included (median age 81 years (25th-75th percentile 77-84.5)). New left bundle branch block occurred in five patients (7.7%) and PPI in two patients (3%). Contact pressure index (CPI) was similar for patients with vs without new conduction disorders. Patients with PPI had numerically higher CPI than those without PPI (median CPI 20.0% (25th-75th percentile 15.0-25.0) vs. 13.0% (25th-75th percentile 5.5-18), p = 0.27). More than trace PVL occurred in 30%. Median PVL was significantly lower in patients with none-trace PVL (3.2 mL/s [25th-75th percentile 2.2-5.0]), compared to mild PVL (5.2 mL/s [25th-75th percentile 3.2-10.3]) and moderate PVL (12.6 mL/s [25th-75th percentile 3.9-21.3])(p = 0.036). A simulated PVL-cutoff of 9.65 mL/s identified patients with >trace PVL (AUC 0.70 (95% CI 0.55-0.85), sensitivity 42%, specificity 95%). CONCLUSION: In our study FEops HEARTguide™ simulations identified patients at risk for >trace PVL with ACURATE Neo2 TAVI but not for PPI.

8.
Article in English | MEDLINE | ID: mdl-39198100

ABSTRACT

BACKGROUND: The off-label utilization of transcatheter heart valve (THV) devices for the treatment of inoperable or high-surgical risk patients with pure native aortic valve regurgitation (NAVR) has demonstrated suboptimal outcomes, both with self- and balloon-expandable (BE) devices. The aim of this study is to compare the use of different BE scaffolds in treating pure NAVR. METHODS: Consecutive patients with pure severe NAVR who were deemed to be at high-risk and were treated with last-generation BE-THVs among seventeen Centers in Europe and US. Technical and device success rates were the primary objectives. RESULTS: Between February 2018 and July 2023, among 144 patients, 41 (28 %) received a MyVal device and 103 (72 %) were treated with a Sapien THV. Patients treated with a MyVal THV had an extra-large annulus more frequently compared to the Sapien group (49%vs.20 %, p < 0.001). Technical and device success rates were 90 % and 81 %, respectively, p > 0.1. The rate of THV migration/embolization (MyVal 4.9%vs. Sapien 11 %, p = 0.4) and second valve needed (4.9%vs.7.8 %, p = 0.7) were numerically lower in the MyVal group, whereas the rate of at least moderate paravalvular leak (15%vs.7.8 %, p = 0.2) and permanent pacemaker implantation (25%vs.18 %, p = 0.16) were numerically higher in the Myval group. CONCLUSIONS: Off-label use of BE devices for pure NAVR represents a potential alternative in high-risk patients in the absence of dedicated devices. However, BE in NAVR is associated with suboptimal outcomes. The availability of larger THV sizes may introduce transcatheter aortic valve replacement as an effective treatment for patients traditionally deemed unsuitable. NON-STANDARD ABBREVIATIONS AND ACRONYMS: AR = aortic regurgitation, BE = balloon-expandable, NAVR = native aortic valve regurgitation, PM = pacemaker, TAVR = transcatheter aortic valve replacement, THV = transcatheter heart valve, TVEM = transcatheter valve embolization and migration, VARC-3 = Valve Academic Research Consortium 3.

9.
Am Heart J ; 278: 1-4, 2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39178978
10.
Neth Heart J ; 32(10): 348-355, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39164507

ABSTRACT

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is considered a safe and effective alternative to surgical aortic valve replacement (SAVR) for elderly patients across the operative risk spectrum. In the Netherlands, TAVI is reimbursed only for patients with a high operative risk. Despite this, one fifth of TAVI patients are < 75 years of age. We aim to compare patient characteristics and outcomes of TAVI and SAVR patients < 75 years. METHODS: This study included all patients < 75 years without active endocarditis undergoing TAVI or SAVR for severe aortic stenosis, mixed aortic valve disease or degenerated aortic bioprosthesis between 2015 and 2020 at the Erasmus University Medical Centre. Dutch authority guidelines were used to classify operative risk. RESULTS: TAVI was performed in 292 patients, SAVR in 386 patients. Based on the Dutch risk algorithm, 59.6% of TAVI patients and 19.4% of SAVR patients were at high operative risk. There was no difference in 30-day all-cause mortality between TAVI and SAVR (2.4% vs 0.8%, p = 0.083). One-year and 5­year mortality was higher after TAVI than after SAVR (1-year: 12.5% vs 4.3%, p < 0.001; 5­year: 36.8% vs 12.0%, p < 0.001). Within risk categories we found no difference between treatment strategies. Independent predictors of mortality were cardiovascular comorbidities (left ventricular ejection fraction < 30%, atrial fibrillation, pulmonary hypertension) and the presence of malignancies, liver cirrhosis or immunomodulatory drug use. CONCLUSION: At the Erasmus University Medical Centre, in patients < 75 years, TAVI is selected for higher-risk phenotypes and overall has higher long-term mortality than SAVR. We found no evidence for worse outcome within risk categories.

11.
J Am Coll Cardiol ; 84(9): 848-861, 2024 Aug 27.
Article in English | MEDLINE | ID: mdl-39168571

ABSTRACT

Transcatheter aortic valve (TAV) thrombosis may manifest as subclinical leaflet thrombosis (SLT) and clinical valve thrombosis. SLT is relatively common (10%-20%) after transcatheter aortic valve replacement, but clinical implications are uncertain. Clinical valve thrombosis is rare (1.2%) and associated with bioprosthetic valve failure, neurologic or thromboembolic events, heart failure, and death. Treatment for TAV thrombosis has been understudied. In principle, anticoagulation may prevent TAV thrombosis. Non-vitamin K oral anticoagulants, as compared to antiplatelet therapy, are associated with reduced incidence of SLT, although at the cost of higher bleeding and all-cause mortality risk. We present an overview of existing literature for management of TAV thrombosis and propose a rational treatment algorithm. Vitamin K antagonists or non-vitamin K oral anticoagulants are the cornerstone of antithrombotic treatment. In therapy-resistant or clinically unstable patients, ultraslow, low-dose infusion of thrombolytics seems effective and safe and may be preferred over redo-transcatheter aortic valve replacement or explant surgery.


Subject(s)
Thrombosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Thrombosis/prevention & control , Thrombosis/etiology , Anticoagulants/therapeutic use , Anticoagulants/administration & dosage , Fibrinolytic Agents/therapeutic use , Aortic Valve/surgery , Heart Valve Prosthesis/adverse effects
12.
Am Heart J ; 277: 104-113, 2024 Nov.
Article in English | MEDLINE | ID: mdl-39121916

ABSTRACT

BACKGROUND: About half of patients with severe aortic stenosis present with concomitant coronary artery disease. The optimal timing of percutaneous coronary intervention (PCI) and transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and concomitant coronary artery disease remains unknown. STUDY DESIGN: The TAVI PCI trial is a prospective, international, multicenter, randomized, 2-arm, open-label study planning to enroll a total of 986 patients. It is designed to investigate whether the strategy "angiography-guided complete revascularization after (within 1-45 days) TAVI" is noninferior to the strategy "angiography-guided complete revascularization before (within 1-45 days) TAVI" using the Edwards SAPIEN 3 or 3 Ultra Transcatheter Heart Valve in patients with severe aortic stenosis and concomitant coronary artery disease. Patients are randomized in a 1:1 ratio to one of the 2 treatment strategies. The primary end point is a composite of all-cause death, nonfatal myocardial infarction, ischemia-driven revascularization, rehospitalization (valve- or procedure-related including heart failure), or life-threatening/disabling or major bleeding at 1 year. CONCLUSIONS: The TAVI PCI trial tests the hypothesis that the strategy "PCI after TAVI" is noninferior to the strategy "PCI before TAVI" in patients with severe aortic stenosis and concomitant coronary artery disease.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Percutaneous Coronary Intervention , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Percutaneous Coronary Intervention/methods , Coronary Artery Disease/surgery , Coronary Artery Disease/complications , Coronary Artery Disease/therapy , Prospective Studies , Male , Female , Coronary Angiography , Treatment Outcome
13.
N Engl J Med ; 2024 Aug 31.
Article in English | MEDLINE | ID: mdl-39216096

ABSTRACT

BACKGROUND: One third of patients undergoing transcatheter aortic-valve implantation (TAVI) have an indication for oral anticoagulation owing to concomitant diseases. Interruption of oral anticoagulation during TAVI may decrease the risk of bleeding, whereas continuation may decrease the risk of thromboembolism. METHODS: We conducted an international, open-label, randomized, noninferiority trial involving patients who were receiving oral anticoagulants and were planning to undergo TAVI. Patients were randomly assigned in a 1:1 ratio to periprocedural continuation or interruption of oral anticoagulation. The primary outcome was a composite of death from cardiovascular causes, stroke from any cause, myocardial infarction, major vascular complications, or major bleeding within 30 days after TAVI. RESULTS: A total of 858 patients were included in the modified intention-to-treat population: 431 were assigned to continuation and 427 to interruption of oral anticoagulation. A primary-outcome event occurred in 71 patients (16.5%) in the continuation group and in 63 (14.8%) in the interruption group (risk difference, 1.7 percentage points; 95% confidence interval [CI], -3.1 to 6.6; P = 0.18 for noninferiority). Thromboembolic events occurred in 38 patients (8.8%) in the continuation group and in 35 (8.2%) in the interruption group (risk difference, 0.6 percentage points; 95% CI, -3.1 to 4.4). Bleeding occurred in 134 patients (31.1%) in the continuation group and in 91 (21.3%) in the interruption group (risk difference, 9.8 percentage points; 95% CI, 3.9 to 15.6). CONCLUSIONS: In patients undergoing TAVI with a concomitant indication for oral anticoagulation, periprocedural continuation was not noninferior to interruption of oral anticoagulation during TAVI with respect to the incidence of a composite of death from cardiovascular causes, stroke, myocardial infarction, major vascular complications, or major bleeding at 30 days. (Funded by the Netherlands Organization for Health Research and Development and the St. Antonius Research Fund; POPular PAUSE TAVI ClinicalTrials.gov number, NCT04437303.).

14.
Am J Cardiol ; 227: 98-104, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-39032588

ABSTRACT

In patients with prevalent or incident atrial fibrillation (AF) after successful transcatheter aortic valve implantation (TAVI) enrolled in the EdoxabaN Versus standard of care and theIr effectS on clinical outcomes in pAtients havinG undergonE Transcatheter Aortic Valve Implantation - in Atrial Fibrillation (ENVISAGE-TAVI AF) trial, the incidence of ischemic stroke (IS) and any stroke was numerically less in the edoxaban group than in the vitamin K antagonist (VKA) group. The present study aimed to identify risk factors associated with IS in an on-treatment subanalysis in patients from ENVISAGE-TAVI AF who received ≥1 dose of edoxaban or VKA. Baseline patient characteristics were compared in patients with and those without IS. Numerical variables were compared using a 1-way analysis of variance; categorical variables were compared using Fisher's exact test. Stepwise Cox regression determined patient characteristics associated with the first IS event. Of 1,377 patients, 41 (3.0%) experienced an IS, and 1,336 (97.0%) did not; baseline demographics and clinical characteristics were well balanced between groups. Most ISs occurred within 180 days of TAVI for edoxaban (57.9%) and VKA (68.2%). The rate of IS was 2.0/100 person-years for edoxaban versus 2.7/100 person-years for VKA. Independently associated with IS were history of systemic embolic events (hazard ratio 2.96, 95% confidence interval 1.26 to 7.00, p = 0.01) and pre-TAVI use of VKAs (hazard ratio 2.17, 95% confidence interval 1.12 to 4.20, p = 0.02). In conclusion, although the overall incidence of IS was small for patients with AF on edoxaban or VKA after successful TAVI, patients with a history of systemic embolic events or pre-TAVI use of VKAs may be at greater risk of IS after TAVI.


Subject(s)
Aortic Valve Stenosis , Atrial Fibrillation , Factor Xa Inhibitors , Ischemic Stroke , Pyridines , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Atrial Fibrillation/epidemiology , Atrial Fibrillation/complications , Male , Female , Ischemic Stroke/epidemiology , Ischemic Stroke/prevention & control , Ischemic Stroke/etiology , Risk Factors , Aged, 80 and over , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Factor Xa Inhibitors/therapeutic use , Incidence , Pyridines/therapeutic use , Thiazoles/therapeutic use , Aged , Postoperative Complications/epidemiology , Vitamin K/antagonists & inhibitors
15.
JAMA Cardiol ; 9(9): 817-825, 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-38985461

ABSTRACT

Importance: In older patients with atrial fibrillation who take anticoagulants for stroke prevention, bleeding is increased compared with younger patients, thus, clinicians frequently prescribe lower than recommended doses in older patients despite limited randomized data. Objective: To evaluate ischemic and bleeding outcomes in patients 80 years and older with atrial fibrillation receiving edoxaban, 60 mg vs 30 mg, and edoxaban, 30 mg vs warfarin. Design, Setting, and Participants: The ENGAGE AF-TIMI 48 trial (Effective Anticoagulation With Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis in Myocardial Infarction 48) was a parallel-design, double-blind, global clinical trial that randomized patients with atrial fibrillation to either one of 2 edoxaban dosing regimens or warfarin. This secondary analysis focused on patients 80 years or older without dose-reduction criteria receiving edoxaban, 60 mg vs 30 mg, as well as patients with or without dose-reduction criteria receiving edoxaban, 30 mg, vs warfarin. Study data were analyzed between October 2022 and December 2023. Interventions: Oral edoxaban, 30 mg once daily; edoxaban, 60 mg once daily; or warfarin. Main Outcomes and Measures: Primary net clinical outcome of death, stroke or systemic embolism, and major bleeding and each individual component. Results: The current analysis included 2966 patients 80 years and older (mean [SD] age, 83 [2.7] years; 1671 male [56%]). Among 1138 patients 80 years and older without dose-reduction criteria, those receiving edoxaban, 60 mg vs 30 mg, had more major bleeding events (hazard ratio [HR], 1.57; 95% CI, 1.04-2.38; P = .03), particularly gastrointestinal hemorrhage (HR, 2.24; 95% CI, 1.29-3.90; P = .004), with no significant difference in efficacy end points. Findings were supported by analyses of endogenous factor Xa inhibition, a marker of anticoagulant effect, which was comparable between younger patients receiving edoxaban, 60 mg, and older patients receiving edoxaban, 30 mg. In 2406 patients 80 years and older with or without dose-reduction criteria, patients receiving edoxaban, 30 mg, vs warfarin had lower rates of the primary net clinical outcome (HR, 0.78; 95% CI, 0.68-0.91; P = .001), major bleeding (HR, 0.59; 95% CI, 0.45-0.77; P < .001), and death (HR, 0.83; 95% CI, 0.70-1.00; P = .046), whereas rates of stroke or systemic embolism were comparable. Conclusions and Relevance: In this post hoc analysis of the ENGAGE AF-TIMI 48 randomized clinical trial, in patients 80 years and older with atrial fibrillation, major bleeding events were lower in patients randomized to receive edoxaban, 30 mg per day, compared with either edoxaban, 60 mg per day (in patients without dose-reduction criteria), or warfarin (irrespective of dose-reduction status), without an offsetting increase in ischemic events. These data support the concept that lower-dose anticoagulants, such as edoxaban, 30 mg, may be considered in older patients with atrial fibrillation even in the absence of dose-reduction criteria. Trial Registration: ClinicalTrials.gov Identifier: NCT00781391.


Subject(s)
Atrial Fibrillation , Factor Xa Inhibitors , Pyridines , Thiazoles , Warfarin , Humans , Atrial Fibrillation/drug therapy , Atrial Fibrillation/complications , Male , Thiazoles/administration & dosage , Thiazoles/therapeutic use , Female , Factor Xa Inhibitors/therapeutic use , Factor Xa Inhibitors/administration & dosage , Aged, 80 and over , Pyridines/therapeutic use , Pyridines/administration & dosage , Double-Blind Method , Warfarin/therapeutic use , Warfarin/administration & dosage , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Anticoagulants/administration & dosage , Anticoagulants/therapeutic use , Stroke/prevention & control , Dose-Response Relationship, Drug , Drug Tapering
16.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38986659

ABSTRACT

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve , Heart Valve Prosthesis , Prosthesis Design , Registries , Severity of Illness Index , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve Insufficiency/physiopathology , Aortic Valve Insufficiency/mortality , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Female , Male , Retrospective Studies , Aged , Treatment Outcome , Aged, 80 and over , Risk Factors , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality , Transcatheter Aortic Valve Replacement/instrumentation , Patient Readmission , Recovery of Function , Europe , Heart Failure/mortality , Heart Failure/therapy , Heart Failure/physiopathology , Heart Failure/diagnosis , Hemodynamics
17.
EuroIntervention ; 20(14): e865-e875, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39007832

ABSTRACT

BACKGROUND: Complete revascularisation is supported by recent trials in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease (MVD) without cardiogenic shock. However, the optimal timing of non-culprit lesion revascularisation is currently debated. AIMS: This prespecified analysis of the BioVasc trial aims to determine the effect of immediate complete revascularisation (ICR) compared to staged complete revascularisation (SCR) on clinical outcomes in patients with STEMI. METHODS: Patients presenting with STEMI and MVD were randomly assigned to ICR or SCR. The primary endpoint was the composite of all-cause mortality, myocardial infarction, any unplanned ischaemia-driven revascularisation, or cerebrovascular events at 1-year post-index procedure. RESULTS: Between June 2018 and October 2021, 608 (ICR: 305, SCR: 303) STEMI patients were enrolled. No significant differences between ICR and SCR were observed at 1-year follow-up in terms of the primary endpoint (7.0% vs 8.3%, hazard ratio [HR] 0.84, 95% confidence interval [CI]: 0.47-1.50; p=0.55): all-cause mortality (2.3% vs 1.3%, HR 1.77, 95% CI: 0.52-6.04; p=0.36), myocardial infarction (1.7% vs 3.3%, HR 0.50, 95% CI: 0.17-1.47; p=0.21), unplanned ischaemia-driven revascularisation (4.1% vs 5.0%, HR 0.80, 95% CI: 0.38-1.71; p=0.57) and cerebrovascular events (1.4% vs 1.3%, HR 1.01, 95% CI: 0.25-4.03; p=0.99). At 30-day follow-up, a trend towards a reduction of the primary endpoint in the ICR group was observed (ICR: 3.0% vs SCR: 6.0%, HR 0.50, 95% CI: 0.22-1.11; p=0.09). ICR was associated with a reduction in overall hospital stay (ICR: median 3 [interquartile range {IQR} 2-5] days vs SCR: median 4 [IQR 3-6] days; p<0.001). CONCLUSIONS: Clinical outcomes at 1 year were similar for STEMI patients who had undergone ICR and those who had undergone SCR.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , ST Elevation Myocardial Infarction , Humans , ST Elevation Myocardial Infarction/surgery , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/therapy , Male , Female , Middle Aged , Percutaneous Coronary Intervention/methods , Aged , Treatment Outcome , Coronary Artery Disease/surgery , Coronary Artery Disease/mortality , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Time Factors , Time-to-Treatment , Myocardial Revascularization/methods
18.
Article in English | MEDLINE | ID: mdl-38970592

ABSTRACT

Inter-echocardiography core laboratory (ECL) harmonization is pivotal to consider data from different ECLs interchangeable. On the basis of the experience of the first trans-Atlantic harmonization of 2 established ECLs in the field of transcatheter aortic valve replacement (TAVR) trials, this review describes the harmonized ECL methodology in analyzing and adjudicating the post-TAVR echocardiographic endpoints according to Valve Academic Research Consortium 3 definitions. This review presents the feasibility and intra- and inter-ECL reproducibility, explains the root cause of potential important inter-ECL variability, and formulates ECL recommendations for optimal post-TAVR echocardiographic image acquisition. The implementation of inter-ECL harmonization may further define the best practice of ECLs and have logistic and regulatory implications for the realization of future TAVR trials.

19.
Article in English | MEDLINE | ID: mdl-38970594

ABSTRACT

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

20.
Eur J Heart Fail ; 26(8): 1736-1744, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38825743

ABSTRACT

AIMS: Heart failure (HF), a global pandemic affecting millions of individuals, calls for adequate predictive guidance for improved therapy. Congestion, a key factor in HF-related hospitalizations, further underscores the need for timely interventions. Proactive monitoring of intracardiac pressures, guided by pulmonary artery (PA) pressure, offers opportunities for efficient early-stage intervention, since haemodynamic congestion precedes clinical symptoms. METHODS: The BioMEMS study, a substudy of the MONITOR-HF trial, proposes a multifaceted approach integrating blood biobank data with traditional and novel HF parameters. Two additional blood samples from 340 active participants in the MONITOR-HF trial were collected at baseline, 3-, 6-, and 12-month visits and stored for the BioMEMS biobank. The main aims are to identify the relationship between temporal biomarker patterns and PA pressures derived from the CardioMEMS-HF system, and to identify the biomarker profile(s) associated with the risk of HF events and cardiovascular death. CONCLUSION: Since the prognostic value of single baseline measurements of biomarkers like N-terminal pro-B-type natriuretic peptide is limited, with the BioMEMS study we advocate a dynamic, serial approach to better capture HF progression. We will substantiate this by relating repeated biomarker measurements to PA pressures. This design rationale presents a comprehensive review on cardiac biomarkers in HF, and aims to contribute valuable insights into personalized HF therapy and patient risk assessment, advancing our ability to address the evolving nature of HF effectively.


Subject(s)
Biomarkers , Heart Failure , Pulmonary Artery , Humans , Heart Failure/physiopathology , Heart Failure/blood , Biomarkers/blood , Prognosis , Pulmonary Artery/physiopathology , Female , Male , Natriuretic Peptide, Brain/blood , Peptide Fragments/blood , Aged , Pulmonary Wedge Pressure/physiology , Chronic Disease , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL