Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 178
Filter
1.
Appl Spectrosc ; : 37028241263567, 2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38881037

ABSTRACT

The almost-two-centuries history of spectrochemical analysis has generated a body of literature so vast that it has become nearly intractable for experts, much less for those wishing to enter the field. Authoritative, focused reviews help to address this problem but become so granular that the overall directions of the field are lost. This broader perspective can be provided partially by general overviews but then the thinking, experimental details, theoretical underpinnings and instrumental innovations of the original work must be sacrificed. In the present compilation, this dilemma is overcome by assembling the most impactful publications in the area of analytical atomic spectrometry. Each entry was proposed by at least one current expert in the field and supported by a narrative that justifies its inclusion. The entries were then assembled into a coherent sequence and returned to contributors for a round-robin review.

2.
Anal Chim Acta ; 1315: 342812, 2024 Aug 01.
Article in English | MEDLINE | ID: mdl-38879212

ABSTRACT

BACKGROUND: Potassium isotopic analysis is increasingly performed in both geological and biological contexts as a result of the introduction of MC-ICP-MS instrumentation either equipped with a collision/reaction cell or having the capability of working at "extra-high" mass resolution in order to deal with spectral interference caused by argon hydride (ArH+) ions. Potassium plays an important role in the central nervous system, and its isotopic analysis could provide an enhanced insight into the corresponding processes, but K isotopic analysis of cerebrospinal fluid is challenging due to the small volume, a few microliter only, typically available. This work aimed at developing a method for determining the K isotopic signature of serum and cerebrospinal fluid at a final K concentration of 25 ng mL-1 using Faraday cup amplifiers equipped with a 1013 Ω resistor. RESULTS: Potassium isotope ratios obtained for reference materials measured at a final K concentration of 25 ng mL-1 were in excellent agreement with the corresponding reference values and the internal and external precision for the δ41K value was 0.11 ‰ (2SE, N = 50) and 0.10 ‰ (2SD, N = 6), respectively. The robustness against the presence of matrix elements and the concentration mismatch between sample and standard observed at higher K concentrations is preserved at low K concentration. Finally, K isotopic analysis of serum and cerebrospinal fluid (3-12 µL of sample) of healthy mice of both sexes was performed, revealing a trend towards an isotopically lighter signature for serum and cerebrospinal fluid from female individuals, however being significant for serum only. SIGNIFICANCE: This work provides a robust method for high-precision K isotopic analysis at a concentration of 25 ng mL-1. By monitoring both K isotopes, 39K and 41K, with Faraday cups connected to amplifiers with 1013 Ω resistors, accurate K isotope ratio results are obtained with a two-fold improvement in internal and external precision compared to those obtained with the set-up with traditional 1011 Ω resistors. The difference in the K isotope ratio in CSF and serum between the sexes, is possibly indicating an influence of the sex or hormones on the fractionation effects accompanying cellular uptake/release.


Subject(s)
Mass Spectrometry , Potassium , Animals , Potassium/blood , Potassium/cerebrospinal fluid , Female , Male , Mice , Isotopes , Humans
3.
Talanta ; 276: 126210, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38728804

ABSTRACT

High-precision isotopic analysis of mercury (Hg) using multi-collector ICP-mass spectrometry (MC-ICP-MS) is a powerful method for obtaining insight into the sources, pathways and sinks of this toxic metal. Modification of a commercially available mercury analyzer (Teledyne Leeman Labs, Hydra IIc - originally designed for quantification of Hg through sample combustion, collection of the Hg vapor on a gold amalgamator, subsequent controlled release of Hg and detection using cold vapor atomic absorption spectrometry CVAAS) enabled the system to be used for the direct high-precision Hg isotopic analysis of solid samples using MC-ICP-MS - i.e., without previous sample digestion and subsequent dilution. The changes made to the mercury analyzer did not compromise its (simultaneous) use for Hg quantification via CVAAS. The Hg vapor was mixed with a Tl-containing aerosol produced via pneumatic nebulization, creating wet plasma conditions, and enabling the use of Tl as an internal standard for correction of instrumental mass discrimination. Accurate and precise (0.10 ‰ 2SD, δ202Hg, n = 5) results were obtained for an in-house standard solution of Hg (20 ng Hg sample intake). Initial validation relied on the successful analysis of two solid certified reference materials of biological origin (BCR CRM 464 Tuna fish and NRC-CNRC TORT-3 Lobster hepatopancreas). It was shown that instrumental mass discrimination can be adequately corrected for by relying on the use of an aqueous Hg standard solution (NIST SRM 3133), without the need of matrix-matching. The novel setup developed thus allows for direct high-precision isotopic analysis of Hg in solid samples, thus enhancing the sample throughput. It is also suited for samples for which low amounts are available only and/or that are characterized by low Hg concentrations.

5.
Anal Chim Acta ; 1287: 342089, 2024 Jan 25.
Article in English | MEDLINE | ID: mdl-38182382

ABSTRACT

BACKGROUND: Recent papers on LA-ICP-MS have reported that certain elements are transported in particulate form, others in gaseous form and still others in a combination of both upon ablation of C-based materials. These two phases display different transport behaviour characteristics, potentially causing smearing in elemental maps, and could be processed differently in the ICP which raises concerns as to accuracy of quantification and emphasizes the need for matrix-matching of external standards. This work aims at a better understanding of two-phase sample transport by evaluating the peak profile changes observed upon varying parameters such as laser energy density and wavelength. RESULTS: It is demonstrated that upon ablation of gelatin, elements are transported predominantly in particulate phase, but already at low laser energy density, a significant fraction of some elements is transported in the gaseous phase, which is even more expressed at higher energy density. This behaviour is element-specific since the ratio of the signal intensity for the analyte element transported in gas phase to the total signal intensity was 0 % for 23Na, 43 % for 66Zn and as high as 95 % for 13C using a 193 nm laser. The results also suggest an effect of the laser wavelength, as all elements show either the same or higher amount of gas phase formation upon ablating with 213 nm versus 193 nm. It was even established that elements that fully occur in particulate form upon ablation using 193 nm laser radiation are partly converted into gaseous phase when using 213 nm. SIGNIFICANCE: This work provides a thorough investigation of the underexposed phenomenon of two-phase sample transport upon ablation of biological samples upon via LA-ICP-MS. It is shown that for some elements a fraction of the ablated material is converted and transported in the gas phase, which can lead to significant smearing effects. As such, it is important to evaluate element-specific peak profiles on beforehand and, if necessary, adapt instrument settings and slow down data acquisition.


Subject(s)
Gelatin , Laser Therapy , Gases , Spectrum Analysis , Mass Spectrometry
6.
Anal Chem ; 95(50): 18579-18586, 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38050919

ABSTRACT

In this work, laser ablation (LA) was characterized as a method for sampling and introducing microplastic particles (MPs) into an inductively coupled plasma (ICP) for subsequent 13C+ monitoring using an ICP-mass spectrometer operated in single-event mode. MPs of different types (PS, PMMA, and PVC) and sizes (2-20 µm) were introduced intactly. The laser energy density did not affect the particle sampling across a wide range (0.25-6.00 J cm-2). Single-shot analysis separated clustered MPs (2-7 MPs per cluster) during the LA and particle transport processes, allowing the temporally resolved analysis of the individual constituting MPs. Line scanning showed superior performance when using a small laser beam diameter combined with a high repetition rate. The 13C+ signal intensity correlated linearly (R2 >0.9945) with the absolute C mass in a 2-10 µm size range, while the use of He in the collision-reaction cell (CRC) allowed extension of the linear range to 20 µm. The LA approach generated narrower 13C+ signal distributions than the traditional solution-based approach (dry versus wet plasma conditions) and proved successful for the analysis of a mixed suspension (containing four sizes of PS MPs in a 2-5 µm size range) and for sampling MPs from PVDF and glass microfiber filters, with the latter offering a lower background.

7.
Int J Mol Sci ; 24(21)2023 Oct 27.
Article in English | MEDLINE | ID: mdl-37958667

ABSTRACT

Hypomagnesemia was historically prevalent in individuals with type 1 diabetes mellitus (T1DM), but contemporary results indicate an incidence comparable to that in the general population, likely due to improved treatment in recent decades, resulting in better glycemic control. However, a recent study found a significant difference between the serum Mg isotopic composition of T1DM individuals and controls, indicating that disruptions to Mg homeostasis persist. Significant deviations were also found in samples taken one year apart. To investigate whether the temporal variability in serum Mg isotopic composition is linked to the transient impact of administered insulin, Mg isotope ratios were determined in serum from 15 T1DM individuals before and one hour after insulin injection/meal consumption using multi-collector inductively coupled plasma-mass spectrometry. Consistent with results of the previous study, significant difference in the serum Mg isotopic composition was found between T1DM individuals and 10 sex-matched controls. However, the average difference between pre- and post-insulin injection/meal T1DM samples of 0.05 ± 0.13‱ (1SD) was not significant. No difference was observed for controls before (-0.12 ± 0.16‱) and after the meal (-0.10 ± 0.13‱) either, suggesting a lack of a postprandial Mg isotopic response within one hour of food consumption, and that the timing of the most recent meal may not require controlling for when determining serum Mg isotopic composition.


Subject(s)
Diabetes Mellitus, Type 1 , Humans , Isotopes , Magnesium , Insulin , Insulin, Regular, Human
8.
ACS Nano ; 17(20): 20002-20012, 2023 Oct 24.
Article in English | MEDLINE | ID: mdl-37787479

ABSTRACT

Colloidal InAs quantum dots (QDs) are widely studied as a printable optoelectronic material for short-wave infrared (SWIR) that is not restricted by regulations on hazardous substances. Such applications, however, require synthetic procedures that yield QDs with adjustable sizes at the end of the reaction. Here, we show that such one-size-one-batch protocols can be realized through temperature profiles that involve a rapid transition from a lower injection temperature to a higher reaction temperature. By expediting the transition to the reaction temperature and reducing the overall synthesis concentration, we can tune QD sizes from 4.5 to 10 nm, the latter corresponding to a band gap transition at 1600 nm. We argue that the temperature ramps provide a more distinct separation between nucleation at low temperature and growth at high temperature such that larger QDs are obtained by minimizing the nucleation time. The synthetic procedures introduced here will strongly promote the development of a SWIR optoelectronic technology based on InAs QDs, while the use of temperature profiles to steer a colloidal synthesis can find applications well beyond the specific case of InAs QDs.

9.
ACS Appl Mater Interfaces ; 15(42): 49022-49034, 2023 Oct 25.
Article in English | MEDLINE | ID: mdl-37819736

ABSTRACT

Because peritoneal metastasis (PM) from ovarian cancer is characterized by non-specific symptoms, it is often diagnosed at advanced stages. Pressurized intraperitoneal aerosol chemotherapy (PIPAC) can be considered a promising drug delivery method for unresectable PM. Currently, the efficacy of intraperitoneal (IP) drug delivery is limited by the off-label use of IV chemotherapeutic solutions, which are rapidly cleared from the IP cavity. Hence, this research aimed to improve PM treatment by evaluating a nanoparticle-loaded, pH-switchable supramolecular polymer hydrogel as a controlled release drug delivery system that can be IP nebulized. Moreover, a multidirectional nozzle was developed to allow nebulization of viscous materials such as hydrogels and to reach an even IP gel deposition. We demonstrated that acidification of the nebulized hydrogelator solution by carbon dioxide, used to inflate the IP cavity during laparoscopic surgery, stimulated the in situ gelation, which prolonged the IP hydrogel retention. In vitro experiments indicated that paclitaxel nanocrystals were gradually released from the hydrogel depot formed, which sustained the cytotoxicity of the formulation for 10 days. Finally, after aerosolization of this material in a xenograft model of PM, tumor progression could successfully be delayed, while the overall survival time was significantly increased compared to non-treated animals.


Subject(s)
Carbon Dioxide , Peritoneal Neoplasms , Animals , Humans , Peritoneal Neoplasms/drug therapy , Hydrogels/chemistry , Polymers/chemistry , Hydrogen-Ion Concentration
10.
Nanoscale ; 15(26): 11268-11279, 2023 Jul 06.
Article in English | MEDLINE | ID: mdl-37345980

ABSTRACT

This study describes an interlaboratory comparison (ILC) among nine (9) laboratories to evaluate and validate the standard operation procedure (SOP) for single-particle (sp) ICP-TOFMS developed within the context of the Horizon 2020 project ACEnano. The ILC was based on the characterization of two different Pt nanoparticle (NP) suspensions in terms of particle mass, particle number concentration, and isotopic composition. The two Pt NP suspensions were measured using icpTOF instruments (TOFWERK AG, Switzerland). Two Pt NP samples were characterized and mass equivalent spherical sizes (MESSs) of 40.4 ± 7 nm and 58.8 ± 8 nm were obtained, respectively. MESSs showed <16% relative standard deviation (RSD) among all participating labs and <4% RSD after exclusion of the two outliers. A good agreement was achieved between the different participating laboratories regarding particle mass, but the particle number concentration results were more scattered, with <53% RSD among all laboratories, which is consistent with results from previous ILC studies conducted using ICP-MS instrumentation equipped with a sequential mass spectrometer. Additionally, the capabilities of sp-ICP-TOFMS to determine masses on a particle basis are discussed with respect to the potential for particle density determination. Finally, because quasi-simultaneous multi-isotope and multi-element determinations are a strength of ICP-TOFMS instrumentation, the precision and trueness of isotope ratio determinations were assessed. The average of 1000 measured particles yielded a precision of below ±1% for intensity ratios of the most abundant Pt isotopes, i.e.194Pt and 195Pt, while the accuracy of isotope ratios with the lower abundant isotopes was limited by counting statistics.

11.
Biology (Basel) ; 12(6)2023 Jun 14.
Article in English | MEDLINE | ID: mdl-37372142

ABSTRACT

Alzheimer's' disease (AD) is characterized by the formation of ß-amyloid (Aß) plaques and neurofibrillary tangles of tau protein in the brain. Aß plaques are formed by the cleavage of the ß-amyloid precursor protein (APP). In addition to protein aggregations, the metabolism of the essential mineral element Cu is also altered during the pathogenesis of AD. The concentration and the natural isotopic composition of Cu were investigated in blood plasma and multiple brain regions (brain stem, cerebellum, cortex, and hippocampus) of young (3-4 weeks) and aged (27-30 weeks) APPNL-G-F knock-in mice and wild-type controls to assess potential alterations associated with ageing and AD. Tandem inductively coupled plasma-mass spectrometry (ICP-MS/MS) was used for elemental analysis and multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS) for high-precision isotopic analysis. The blood plasma Cu concentration was significantly altered in response to both age- and AD-related effects, whereas the blood plasma Cu isotope ratio was only affected by the development of AD. Changes in the Cu isotopic signature of the cerebellum were significantly correlated with the changes observed in blood plasma. The brain stem showed a significant increase in Cu concentration for both young and aged AD transgenic mice compared with healthy controls, whereas the Cu isotopic signature became lighter as a result of age-related changes. In this work, ICP-MS/MS and MC-ICP-MS provided relevant and complementary information on the potential role of Cu in ageing and AD.

12.
Adv Healthc Mater ; 12(24): e2300594, 2023 09.
Article in English | MEDLINE | ID: mdl-37247322

ABSTRACT

The ability to improve nanoparticle delivery to solid tumors is an actively studied domain, where various mechanisms are looked into. In previous work, the authors have looked into nanoparticle size, tumor vessel normalization, and disintegration, and here it is aimed to continue this work by performing an in-depth mechanistic study on the use of ciRGD peptide co-administration. Using a multiparametric approach, it is observed that ciRGD can improve nanoparticle delivery to the tumor itself, but also to tumor cells specifically better than vessel normalization strategies. The effect depends on the level of tumor perfusion, hypoxia, neutrophil levels, and vessel permeability. This work shows that upon characterizing tumors for these parameters, conditions can be selected that can optimally benefit from ciRGD co-administration as a means to improve NP delivery to solid tumors.


Subject(s)
Nanoparticles , Neoplasms , Humans , Neuropilin-1/therapeutic use , Neutrophils , Drug Delivery Systems , Neoplasms/drug therapy , Neoplasms/pathology , Nanoparticles/chemistry , Hypoxia
13.
Am J Biol Anthropol ; 181(2): 231-249, 2023 06.
Article in English | MEDLINE | ID: mdl-37021710

ABSTRACT

OBJECTIVES: So far, no 87 Sr/86 Sr mobility studies have been done for Neolithic remains from Belgium and information on the Sr isotopic variability in the region is scarce. This study aims to explore mobility in a Final Neolithic population from the funerary cave 'Grotte de La Faucille', contribute to the understanding of the isotopic composition of bioavailable Sr in Belgium, assess evidence for male mobility using proteomic analysis, and explore possible places of origin for nonlocal individuals. MATERIALS AND METHODS: The 87 Sr/86 Sr isotope ratio of dental enamel from six adults and six juveniles was determined. Liquid chromatography mass spectrometry-based protein analysis was employed to identify individuals of male biological sex. 87 Sr/86 Sr of micromammal teeth, snail shells, and modern plants from three geological areas in Belgium were measured to establish isotopic signatures for bioavailable strontium. Nonlocality was assessed by comparing human 87 Sr/86 Sr isotope ratios to the 87 Sr/86 Sr range for bioavailable Sr. RESULTS: Four individuals yielded 87 Sr/86 Sr isotope ratios consistent with a nonlocal origin. No statistical differences were found between adults and juveniles. Three males were detected in the sample set, of which two show nonlocal 87 Sr/86 Sr values. DISCUSSION: This study provides evidence for mobility in Final Neolithic Belgium. The four nonlocal 87 Sr/86 Sr signatures correspond with the 87 Sr/86 Sr of bio-available Sr in Dutch South Limburg, the Black Forest in Southwest Germany, and regions of France, such as parts of the Paris Basin and the Vosges. The results support the ruling hypothesis of connections with Northern France, brought to light by archeological research.


Subject(s)
Proteomics , Strontium Isotopes , Male , Adult , Humans , Belgium , Strontium Isotopes/analysis , Isotopes/analysis , Strontium/analysis
14.
Metallomics ; 15(3)2023 03 06.
Article in English | MEDLINE | ID: mdl-36881726

ABSTRACT

In the last 20 years, the application of high-precision isotopic analysis of essential mineral elements (Mg, K, Ca, Fe, Cu, and Zn) to biomedicine (sometimes referred to as isotope metallomics) has revealed that their stable isotopic compositions are altered by the metal dysregulation that is fundamental to the pathogenesis of many cancers and other diseases. Despite many published works showing the diagnostic and prognostic potential of this approach, a number of factors that may influence the stable isotopic composition of these essential mineral elements in healthy individuals remain unstudied. In this perspective article, we summarize the available evidence from trophic level studies, animal models, and ancient and modern humans, relating to physiological and lifestyle factors that appear likely (there is evidence indicating their influence) or unlikely (there is evidence indicating their lack of influence) to require controlling for when investigating variations in essential mineral element isotopic compositions in human subjects. We also discuss factors that require additional data to properly assess. There is evidence that sex, menopausal status, age, diet, vitamin and metal supplementation, genetic variation, and obesity influence the isotopic composition of at least one essential mineral element in the human body. The task of investigating potential influences on essential mineral element isotopic compositions in the human body is sizeable, but presents an exciting research opportunity, with each incremental advance helping to improve the quality of research output in the context of isotope metallomics.


Subject(s)
Human Body , Isotopes , Animals , Humans , Metals , Minerals , Life Style
15.
J Environ Sci (China) ; 128: 203-212, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36801035

ABSTRACT

Biogenic palladium nanoparticles (bio-Pd NPs) are used for the reductive transformation and/or dehalogenation of persistent micropollutants. In this work, H2 (electron donor) was produced in situ by an electrochemical cell, permitting steered production of differently sized bio-Pd NPs. The catalytic activity was first assessed by the degradation of methyl orange. The NPs showing the highest catalytic activity were selected for the removal of micropollutants from secondary treated municipal wastewater. The synthesis at different H2 flow rates (0.310 L/hr or 0.646 L/hr) influenced the bio-Pd NPs size. The NPs produced over 6 hr at a low H2 flow rate had a larger size (D50 = 39.0 nm) than those produced in 3 hr at a high H2 flow rate (D50 = 23.2 nm). Removal of 92.1% and 44.3% of methyl orange was obtained after 30 min for the NPs with sizes of 39.0 nm and 23.2 nm, respectively. Bio-Pd NPs of 39.0 nm were used to treat micropollutants present in secondary treated municipal wastewater at concentrations ranging from µg/L to ng/L. Effective removal of 8 compounds was observed: ibuprofen (69.5%) < sulfamethoxazole (80.6%) < naproxen (81.4%) < furosemide (89.7%) < citalopram (91.7%) < diclofenac (91.9%) < atorvastatin (> 94.3%) < lorazepam (97.2%). Removal of fluorinated antibiotics occurred at > 90% efficiency. Overall, these data indicate that the size, and thus the catalytic activity of the NPs can be steered and that the removal of challenging micropollutants at environmentally relevant concentrations can be achieved through the use of bio-Pd NPs.


Subject(s)
Metal Nanoparticles , Water Pollutants, Chemical , Water Purification , Wastewater , Palladium/chemistry , Water Pollutants, Chemical/metabolism
16.
Anal Chim Acta ; 1240: 340744, 2023 Feb 01.
Article in English | MEDLINE | ID: mdl-36641153

ABSTRACT

Sulfur isotope ratios are often used as biogeochemical tracers to gain understanding of abiotic and biological processes involved in the sulfur cycle in both modern and ancient environments. There is however a lack of matrix-matched well-characterized isotopic reference materials that are essential for controlling the accuracy and precision. This study therefore focused on expanding and complementing the currently available sulfur isotope ratio data by providing the bulk sulfur isotopic composition, as determined using multi-collector inductively coupled plasma-mass spectrometry (MC-ICP-MS), for a comprehensive set of commercially and/or readily available biological and geological reference materials. A total 7 isotopic reference materials and 41 elemental reference materials were studied. These reference materials include standards of terrestrial and marine animal origin, terrestrial plant origin, human origin, and geological origin. Different sample preparation protocols, including digestion and subsequent chromatographic isolation of S, were evaluated and the optimum approach selected for each matrix type. For achieving enhanced robustness, the sample preparation and sulfur isotope ratio measurements were done at two different laboratories for selected reference materials, while at one of the laboratories the measurements were additionally performed using two different MC-ICP-MS instruments. Determined δ34SVCDT and δ33SVCDT values compared well between the different laboratories, as well as between the different generation MC-ICP-MS instruments, and for standards that were previously characterized, our data are similar to literature values. The δ34SVCDT ranges determined for the different categories of the reference materials - terrestrial animal origin: +2 to +9‰, marine animal origin: +15 to +20‰, human origin: +6 to +10‰, terrestrial plant origin: -20 to +7‰, and geological origin: -12 to +21‰ - fit the expected values based on previous studies of similar types of matrices well. No significant mass-independent fractionation is observed when considering the expanded uncertainties for Δ33SV-CDT.


Subject(s)
Sulfur , Animals , Humans , Mass Spectrometry/methods , Sulfur Isotopes/analysis , Spectrum Analysis
17.
Microb Biotechnol ; 16(5): 901-914, 2023 05.
Article in English | MEDLINE | ID: mdl-36106503

ABSTRACT

The production of biogenic palladium nanoparticles (bio-Pd NPs) is widely studied due to their high catalytic activity, which depends on the size of nanoparticles (NPs). Smaller NPs (here defined as <100 nm) are more efficient due to their higher surface/volume ratio. In this work, inductively coupled plasma-mass spectrometry (ICP-MS), flow cytometry (FCM) and transmission electron microscopy (TEM) were combined to obtain insight into the formation of these bio-Pd NPs. The precipitation of bio-Pd NPs was evaluated on a cell-per-cell basis using single-cell ICP-MS (SC-ICP-MS) combined with TEM images to assess how homogenously the particles were distributed over the cells. The results provided by SC-ICP-MS were consistent with those provided by "bulk" ICP-MS analysis and FCM. It was observed that heterogeneity in the distribution of palladium over an entire cell population is strongly dependent on the Pd2+ concentration, biomass and partial H2 pressure. The latter three parameters affected the particle size, ranging from 15.6 to 560 nm, and exerted a significant impact on the production of the bio-Pd NPs. The TEM combined with SC-ICP-MS revealed that the mass distribution for bacteria with high Pd content (144 fg Pd cell-1 ) indicated the presence of a large number of very small NPs (D50 = 15.6 nm). These results were obtained at high cell density (1 × 105 ± 3 × 104 cells µl-1 ) and H2 partial pressure (180 ml H2 ). In contrast, very large particles (D50 = 560 nm) were observed at low cell density (3 × 104 ± 10 × 102 cells µl-1 ) and H2 partial pressure (10-100 ml H2 ). The influence of the H2 partial pressure on the nanoparticle size and the possibility of size-tuned nanoparticles are presented.


Subject(s)
Metal Nanoparticles , Palladium , Partial Pressure , Mass Spectrometry/methods , Spectrum Analysis
18.
J Nanobiotechnology ; 20(1): 518, 2022 Dec 09.
Article in English | MEDLINE | ID: mdl-36494816

ABSTRACT

Nanoparticle (NP) delivery to solid tumors remains an actively studied field, where several recent studies have shed new insights into the underlying mechanisms and the still overall poor efficacy. In the present study, Au NPs of different sizes were used as model systems to address this topic, where delivery of the systemically administered NPs to the tumor as a whole or to tumor cells specifically was examined in view of a broad range of tumor-associated parameters. Using non-invasive imaging combined with histology, immunohistochemistry, single-cell spatial RNA expression and image-based single cell cytometry revealed a size-dependent complex interaction of multiple parameters that promoted tumor and tumor-cell specific NP delivery. Interestingly, the data show that most NPs are sequestered by tumor-associated macrophages and cancer-associated fibroblasts, while only few NPs reach the actual tumor cells. While perfusion is important, leaky blood vessels were found not to promote NP delivery, but rather that delivery efficacy correlated with the maturity level of tumor-associated blood vessels. In line with recent studies, we found that the presence of specialized endothelial cells, expressing high levels of CD276 and Plvap promoted both tumor delivery and tumor cell-specific delivery of NPs. This study identifies several parameters that can be used to determine the suitability of NP delivery to the tumor region or to tumor cells specifically, and enables personalized approaches for maximal delivery of nanoformulations to the targeted tumor.


Subject(s)
Metal Nanoparticles , Nanoparticles , Neoplasms , Humans , Tumor Microenvironment , Particle Size , Gold/metabolism , Endothelial Cells/metabolism , Neoplasms/metabolism , Drug Delivery Systems/methods , Cell Line, Tumor , B7 Antigens/metabolism
19.
Anal Bioanal Chem ; 414(25): 7517-7530, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35927365

ABSTRACT

This work describes the development of a novel method for quantitative mapping of Hg and Se in mushroom fruit body tissues with laser ablation coupled to inductively coupled plasma-mass spectrometry (LA-ICP-MS). Different parameters of the protocol for preparation of the standards used for quantification via external calibration were assessed, e.g., the dissolution temperature of gelatin standards and the addition of chitosan and L-cysteine as additives to the gelatin-based calibration droplets to better match the sample matrix. While chitosan was not suited for this purpose, the presence of L-cysteine considerably improved the figures of merit of the calibration, leading to limits of detection of 0.006 and 0.3 µg g-1 for Hg and Se, respectively, at a pixel size of 20 × 20 µm. Further, an in-house reference material, ideally suited for the validation of the method for application to mushroom samples, was successfully prepared from a paste of Boletus edulis. The newly developed method was used to investigate the distribution of Hg and Se in tissue sections of five porcini mushroom individuals of three different species (Boletus edulis, Boletus aereus, and Boletus pinophilus) and one sample of a parasol mushroom (Macrolepiota procera). For one sample, additional areas were ablated at higher spatial resolution, with a laser spot size down to 5 µm, which allows a detailed investigation of the spatial distribution of Hg and Se in mushrooms.


Subject(s)
Agaricales , Laser Therapy , Mercury , Selenium , Basidiomycota , Cysteine , Fruit/chemistry , Gelatin , Humans , Mass Spectrometry/methods , Mercury/analysis , Selenium/analysis
20.
Sci Total Environ ; 851(Pt 1): 158226, 2022 Dec 10.
Article in English | MEDLINE | ID: mdl-35998716

ABSTRACT

The Sea Scheldt estuary has been suggested to be a significant pathway for transfer of plastic debris to the North Sea. We have studied 12,801 plastic items that were collected in the Sea Scheldt estuary (Belgium) during 3 sampling campaigns (in spring, summer, and autumn) using a technique called anchor netting. The investigation results indicated that the abundance of plastic debris in the Scheldt River was on average 1.6 × 10-3 items per m3 with an average weight of 0.38 × 10-3 g per m3. Foils were the most abundant form, accounting for >88 % of the samples, followed by fragments for 11 % of the samples and filaments, making up for <1 % of the plastic debris. FTIR spectroscopy of 7 % of the total number of plastic debris items collected in the Sea Scheldt estuary (n = 883) revealed that polypropylene (PP), polyethylene (PE), and polystyrene (PS) originating from disposable packaging materials were the most abundant types of polymers. A limited number of plastic debris items (n = 100) were selected for non-destructive screening of their mineral element composition using micro-X-ray fluorescence spectrometry (µXRF). The corresponding results revealed that S, Ca, Si, P, Al, and Fe were the predominant mineral elements. These elements originate from flame retardants, mineral fillers, and commonly used catalysts for plastic production. Finally, machine learning algorithms were deployed to test a new concept for forensic identification of the different plastic entities based on the most important elements present using a limited subset of PP (n = 36) and PE (n = 35) plastic entities.


Subject(s)
Flame Retardants , Water Pollutants, Chemical , Environmental Monitoring/methods , Estuaries , Flame Retardants/analysis , Plastics/analysis , Polyethylene/analysis , Polymers , Polypropylenes/analysis , Polystyrenes/analysis , Waste Products/analysis , Water Pollutants, Chemical/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...