ABSTRACT
Tissue-engineered vascular grafts (TEVGs) poised for regenerative applications are central to effective vascular repair, with their efficacy being significantly influenced by scaffold architecture and the strategic distribution of bioactive molecules either embedded within the scaffold or elicited from responsive tissues. Despite substantial advancements over recent decades, a thorough understanding of the critical cellular dynamics for clinical success remains to be fully elucidated. Graft failure, often ascribed to thrombogenesis, intimal hyperplasia, or calcification, is predominantly linked to improperly modulated inflammatory reactions. The orchestrated behavior of repopulating cells is crucial for both initial endothelialization and the subsequent differentiation of vascular wall stem cells into functional phenotypes. This necessitates the TEVG to provide an optimal milieu wherein immune cells can promote early angiogenesis and cell recruitment, all while averting persistent inflammation. In this study, we present an innovative TEVG designed to enhance cellular responses by integrating a physicochemical gradient through a multilayered structure utilizing synthetic (poly (ester urethane urea), PEUU) and natural polymers (Gelatin B), thereby modulating inflammatory reactions. The luminal surface is functionalized with a four-arm polyethylene glycol (P4A) to mitigate thrombogenesis, while the incorporation of adhesive peptides (RGD/SV) fosters the adhesion and maturation of functional endothelial cells. The resultant multilayered TEVG, with a diameter of 3.0 cm and a length of 11 cm, exhibits differential porosity along its layers and mechanical properties commensurate with those of native porcine carotid arteries. Analyses indicate high biocompatibility and low thrombogenicity while enabling luminal endothelialization and functional phenotypic behavior, thus limiting inflammation in in-vitro models. The vascular wall demonstrated low immunogenicity with an initial acute inflammatory phase, transitioning towards a pro-regenerative M2 macrophage-predominant phase. These findings underscore the potential of the designed TEVG in inducing favorable immunomodulatory and pro-regenerative environments, thus holding promise for future clinical applications in vascular tissue engineering.
ABSTRACT
Introduction: Thrombogenesis, a major cause of implantable cardiovascular device failure, can be addressed through the use of biodegradable polymers modified with anticoagulating moieties. This study introduces a novel polyester urethane urea (PEUU) functionalized with various anti-platelet deposition molecules for enhanced antiplatelet performance in regenerative cardiovascular devices. Methods: PEUU, synthesized from poly-caprolactone, 1,4-diisocyanatobutane, and putrescine, was chemically oxidized to introduce carboxyl groups, creating PEUU-COOH. This polymer was functionalized in situ with polyethyleneimine, 4-arm polyethylene glycol, seleno-L-cystine, heparin sodium, and fondaparinux. Functionalization was confirmed using Fourier-transformed infrared spectroscopy and X-ray photoelectron spectroscopy. Bio-compatibility and hemocompatibility were validated through metabolic activity and hemolysis assays. The anti-thrombotic activity was assessed using platelet aggregation, lactate dehydrogenase activation assays, and scanning electron microscopy surface imaging. The whole-blood clotting time quantification assay was employed to evaluate anticoagulation properties. Results: Results demonstrated high biocompatibility and hemocompatibility, with the most potent anti-thrombotic activity observed on pegylated surfaces. However, seleno-L-cystine and fondaparinux exhibited no anti-platelet activity. Discussion: The findings highlight the importance of balancing various factors and addressing challenges associated with different approaches when developing innovative surface modifications for cardiovascular devices.
ABSTRACT
BACKGROUND: A wearable artificial lung could improve lung transplantation outcomes by easing implementation of physical rehabilitation during long-term pretransplant respiratory support. The Modular Extracorporeal Lung Assist System (ModELAS) is a compact pumping artificial lung currently under development. This study evaluated the long-term in vivo performance of the ModELAS during venovenous support in awake sheep. Feedback from early trials and computational fluid dynamic analysis guided device design optimization along the way. METHODS: The ModELAS was connected to healthy sheep via a dual-lumen cannula in the jugular vein. Sheep were housed in a fixed-tether pen while wearing the device in a holster during support. Targeted blood flow rate and support duration were 2-2.5 L/min and 28-30 days, respectively. Anticoagulation was maintained via systemic heparin. Device pumping and gas exchange performance and hematologic indicators of sheep physiology were measured throughout support. RESULTS: Computational fluid dynamic-guided design modifications successfully decreased pump thrombogenicity from initial designs. For the optimized design, 4 of 5 trials advancing past early perioperative and cannula-related complications lasted the full month of support. Blood flow rate and CO2 removal in these trials were 2.1 ± 0.3 L/min and 139 ± 15 mL/min, respectively, and were stable during support. One trial ended after 22 days of support due to intradevice thrombosis. Support was well tolerated by the sheep with no signs of hemolysis or device-related organ impairment. CONCLUSIONS: These results demonstrate the ability of the ModELAS to provide safe month-long support without consistent deterioration of pumping or gas exchange capabilities.
Subject(s)
Artificial Organs , Extracorporeal Circulation/instrumentation , Lung Transplantation , Lung/surgery , Pulmonary Gas Exchange , Respiration , Animals , Equipment Design , Extracorporeal Circulation/adverse effects , Lung/physiopathology , Pulmonary Circulation , Sheep, Domestic , Time FactorsABSTRACT
OBJECTIVE: Ideal heart valve solutions aim to provide thrombosis-free durability. A scaffold-based polycarbonate urethane urea tissue-engineered heart valve designed to mimic native valve microstructure and function was used. This study examined the acute in vivo function of a stented tissue-engineered heart valve in a porcine model. METHODS: Trileaflet valves were fabricated by electrospinning polycarbonate urethane urea using double component fiber deposition. The tissue-engineered heart valve was mounted on an AZ31 magnesium alloy biodegradable stent frame. Five 80-kg Yorkshire pigs underwent open tissue-engineered heart valve implantation on cardiopulmonary bypass in the pulmonary position. Tissue-engineered heart valve function was echocardiographically evaluated immediately postimplant and at planned study end points at 1, 4, 8, and 12 hours. Explanted valves underwent biaxial mechanical testing and scanning electron microscopy for ultrastructural analysis and thrombosis detection. RESULTS: All 5 animals underwent successful valve implantation. All were weaned from cardiopulmonary bypass, closed, and recovered until harvest study end point except 1 animal that was found to have congenital tricuspid valve dysplasia and that was euthanized postimplant. All 5 cases revealed postcardiopulmonary bypass normal leaflet function, no regurgitation, and an average peak velocity of 2 m/s, unchanged at end point. All tissue-engineered heart valve leaflets retained microstructural architecture with no platelet activation or thrombosis by scanning electron microscopy. There was microscopic evidence of fibrin deposition on 2 of 5 stent frames, not on the tissue-engineered heart valve. Biaxial stress examination revealed retained postimplant mechanics of tissue-engineered heart valve fibers without functional or ultrastructural degradation. CONCLUSIONS: A biodegradable elastomeric heart valve scaffold for in situ tissue-engineered leaflet replacement is acutely functional and devoid of leaflet microthrombosis.
Subject(s)
Absorbable Implants , Alloys/chemistry , Elastomers/chemistry , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Pulmonary Valve/surgery , Tissue Engineering/methods , Tissue Scaffolds , Animals , Heart Valve Prosthesis Implantation/adverse effects , Materials Testing , Models, Animal , Prosthesis Design , Prosthesis Failure , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/ultrastructure , Stress, Mechanical , Sus scrofa , Thrombosis/etiology , Time FactorsABSTRACT
OBJECTIVE: Tissue-engineered vascular grafts containing adipose-derived mesenchymal stem cells offer an alternative to small-diameter vascular grafts currently used in cardiac and lower-extremity revascularization procedures. Adipose-derived, mesenchymal stem cell-infused, tissue-engineered vascular grafts have been shown to promote remodeling and vascular homeostasis in vivo and offer a possible treatment solution for those with cardiovascular disease. Unfortunately, the time needed to cultivate adipose-derived mesenchymal stem cells remains a large hurdle for tissue-engineered vascular grafts as a treatment option. The purpose of this study was to determine if stromal vascular fraction (known to contain progenitor cells) seeded tissue-engineered vascular grafts would remain patent in vivo and remodel, allowing for a "same-day" process for tissue-engineered vascular graft fabrication and implantation. METHODS: Stromal vascular fraction, obtained from adult human adipose tissue, was seeded within 4 hours after acquisition from the patient onto poly(ester urethane)urea bilayered scaffolds using a customized rotational vacuum seeding device. Constructs were then surgically implanted as abdominal aortic interposition grafts in Lewis rats. RESULTS: Findings revealed patency in 5 of 7 implanted scaffolds at 8 weeks, along with neotissue formation and remodeling occurring in patent tissue-engineered vascular grafts. Patency was documented using angiography and gross inspection, and remodeling and vascular components were detected using immunofluorescent chemistry. CONCLUSIONS: A "same-day" cell-seeded, tissue-engineered vascular graft can remain patent after implantation in vivo, with neotissue formation and remodeling occurring by 8 weeks.
Subject(s)
Adipose Tissue/cytology , Aorta, Abdominal/surgery , Bioprosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Stem Cell Transplantation/instrumentation , Stromal Cells/physiology , Stromal Cells/transplantation , Tissue Engineering/methods , Tissue Scaffolds , Adult , Animals , Aorta, Abdominal/metabolism , Aorta, Abdominal/pathology , Aorta, Abdominal/physiopathology , Biomarkers/metabolism , Cells, Cultured , Feasibility Studies , Female , Humans , Middle Aged , Neointima , Phenotype , Prosthesis Design , Rats, Inbred Lew , Stromal Cells/metabolism , Time Factors , Transplantation, Heterologous , Vascular Patency , Vascular Remodeling , WorkflowABSTRACT
OBJECTIVES: The PediaFlow (HeartWare International, Inc, Framingham, Mass) is a miniature, implantable, rotodynamic, fully magnetically levitated, continuous-flow pediatric ventricular assist device. The fourth-generation PediaFlow was evaluated in vitro and in vivo to characterize performance and biocompatibility. METHODS: Supported by 2 National Heart, Lung, and Blood Institute contract initiatives to address the limited options available for pediatric patients with congenital or acquired cardiac disease, the PediaFlow was developed with the intent to provide chronic cardiac support for infants as small as 3 kg. The University of Pittsburgh-led Consortium evaluated fourth-generation PediaFlow prototypes both in vitro and within a preclinical ovine model (n = 11). The latter experiments led to multiple redesigns of the inflow cannula and outflow graft, resulting in the implantable design represented in the most recent implants (n = 2). RESULTS: With more than a decade of extensive computational and experimental efforts spanning 4 device iterations, the AA battery-sized fourth-generation PediaFlow has an operating range of 0.5 to 1.5 L/min with minimal hemolysis in vitro and excellent hemocompatibility (eg, minimal hemolysis and platelet activation) in vivo. The pump and finalized accompanying implantable components demonstrated preclinical hemodynamics suitable for the intended pediatric application for up to 60 days. CONCLUSIONS: Designated a Humanitarian Use Device for "mechanical circulatory support in neonates, infants, and toddlers weighing up to 20 kg as a bridge to transplant, a bridge to other therapeutic intervention such as surgery, or as a bridge to recovery" by the Food and Drug Administration, these initial results document the biocompatibility and potential of the fourth-generation PediaFlow design to provide chronic pediatric cardiac support.
Subject(s)
Electric Power Supplies , Heart Failure/therapy , Heart-Assist Devices , Hemodynamics , Prosthesis Implantation/instrumentation , Ventricular Function , Age Factors , Animals , Animals, Newborn , Body Weight , Child, Preschool , Electric Power Supplies/adverse effects , Heart Failure/physiopathology , Heart-Assist Devices/adverse effects , Hemolysis , Humans , Infant , Infant, Newborn , Materials Testing , Miniaturization , Prosthesis Design , Sheep, DomesticABSTRACT
OBJECTIVE: One of the rate-limiting barriers within the field of vascular tissue engineering is the lengthy fabrication time associated with expanding appropriate cell types in culture. One particularly attractive cell type for this purpose is the adipose-derived mesenchymal stem cell (AD-MSC), which is abundant and easily harvested from liposuction procedures. Even this cell type has its drawbacks, however, including the required culture period for expansion, which could pose risks of cellular transformation or contamination. Eliminating culture entirely would be ideal to avoid these concerns. In this study, we used the raw population of cells obtained after digestion of human liposuction aspirates, known as the stromal vascular fraction (SVF), as an abundant, culture-free cell source for tissue-engineered vascular grafts (TEVGs). METHODS: SVF cells and donor-paired cultured AD-MSCs were first assessed for their abilities to differentiate into vascular smooth muscle cells (SMCs) after angiotensin II stimulation and to secrete factors (eg, conditioned media) that promote SMC migration. Next, both cell types were incorporated into TEVG scaffolds, implanted as an aortic graft in a Lewis rat model, and assessed for their patency and composition. RESULTS: In general, the human SVF cells were able to perform the same functions as AD-MSCs isolated from the same donor by culture expansion. Specifically, cells within the SVF performed two important functions; namely, they were able to differentiate into SMCs (SVF calponin expression: 16.4% ± 7.7% vs AD-MSC: 19.9%% ± 1.7%) and could secrete promigratory factors (SVF migration rate relative to control: 3.1 ± 0.3 vs AD-MSC: 2.5 ± 0.5). The SVF cells were also capable of being seeded within biodegradable, elastomeric, porous scaffolds that, when implanted in vivo for 8 weeks, generated patent TEVGs (SVF: 83% patency vs AD-MSC: 100% patency) populated with primary vascular components (eg, SMCs, endothelial cells, collagen, and elastin). CONCLUSIONS: Human adipose tissue can be used as a culture-free cell source to create TEVGs, laying the groundwork for the rapid production of cell-seeded grafts.
Subject(s)
Adipose Tissue/blood supply , Bioprosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Muscle, Smooth, Vascular/transplantation , Myocytes, Smooth Muscle/transplantation , Stromal Cells/transplantation , Tissue Engineering/methods , Adult , Angiotensin II/pharmacology , Animals , Aorta, Abdominal/metabolism , Aorta, Abdominal/pathology , Aorta, Abdominal/surgery , Blood Vessel Prosthesis Implantation/methods , Cell Differentiation , Cell Movement , Cell Separation , Cells, Cultured , Female , Humans , Lipectomy , Mesenchymal Stem Cell Transplantation , Mesenchymal Stem Cells/drug effects , Mesenchymal Stem Cells/metabolism , Muscle, Smooth, Vascular/drug effects , Muscle, Smooth, Vascular/metabolism , Myocytes, Smooth Muscle/drug effects , Myocytes, Smooth Muscle/metabolism , Phenotype , Rats, Inbred Lew , Stromal Cells/drug effects , Stromal Cells/metabolism , Time Factors , Tissue ScaffoldsABSTRACT
OBJECTIVE: Ascending thoracic aortic aneurysm (ATAA) in patients with bicuspid aortic valve (BAV) commonly dilate asymmetrically compared with patients with tricuspid aortic valve (TAV). This discrepancy in aneurysm geometry led us to hypothesize that microarchitectural differences underlie the observed asymmetric dilatation pattern. The purpose of this study was to characterize the microarchitectural distinctions of the extracellular matrix of the 2 phenotypes with a focus on the proportion of radially oriented elastin and collagen fibers in different circumferential aortic regions. METHODS: Aortic tissue rings were obtained just distal to the sinotubular junction from patients with BAV or TAV undergoing elective aneurysm repair. They were sectioned into three circumferentially based regions according to adjacent aortic sinus segment (left coronary sinus [L], right coronary sinus [R], or noncoronary sinus [N]). Multiphoton microscopy was used to quantify and characterize the number of radially oriented elastin and collagen fibers. RESULTS: There were fewer radially oriented fibers in medial region N and medial-intimal region R of BAV-ATAAs when compared with TAV-ATAAs (medial region N, amplitude of angular undulation of elastin = 10.67° ± 1.35° vs 15.58° ± 1.91°; P = .041; medial-intimal region R, amplitude of angular undulation of elastin = 9.83° ± 0.83° vs 14.72° ± 1.64°; P = .015). Conversely, fibers became more radially oriented in the medial-intimal region L of BAV-ATAA when compared with TAV-ATAA (amplitude of angular undulation of collagen = 18.67° ± 0.95° vs 14.56° ± 1.37°; P = .041). CONCLUSIONS: The differential pattern of fiber orientation noted between L and N-R regions help explain the unique pattern of greater curvature dilatation of BAV-ATAA. The distinctions noted in matrix microarchitecture may form the basis of differing aneurysm geometries and aortic wall integrities in ATAAs arising in these different valve morphologies.