Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 50
Filter
1.
Article in English | MEDLINE | ID: mdl-38860493

ABSTRACT

AIMS: Transthoracic echocardiography is recommended in all patients with acute coronary syndrome but is time-consuming and lacks an evidence base. We aimed to assess the feasibility, diagnostic accuracy and time-efficiency of hand-held echocardiography in patients with acute coronary syndrome and describe the impact of echocardiography on clinical management in this setting. METHODS AND RESULTS: Patients with acute coronary syndrome underwent both hand-held and transthoracic echocardiography with agreement between key imaging parameters assessed using kappa statistics. The immediate clinical impact of hand-held echocardiography in this population was systematically evaluated.Overall, 262 patients (65±12 years, 71% male) participated. Agreement between hand-held and transthoracic echocardiography was good-to-excellent (kappa 0.60-1.00) with hand-held echocardiography having an overall negative predictive value of 95%. Hand-held echocardiography was performed rapidly (7.7±1.6 min) and completed a median of 5 [interquartile range 3-20] hours earlier than transthoracic echocardiography. Systematic hand-held echocardiography in all patients with acute coronary syndrome identified an important cardiac abnormality in 50% and the clinical management plan was changed by echocardiography in 42%. In 85% of cases, hand-held echocardiography was sufficient for patient decision-making and transthoracic echocardiography was no longer deemed necessary. CONCLUSIONS: In patients with acute coronary syndrome, hand-held echocardiography provides comparable results to transthoracic echocardiography, can be more rapidly applied and gives sufficient imaging information for decision-making in the vast majority of patients. Systematic echocardiography has clinical impact in half of patients, supporting the clinical utility of echocardiography in this population, and providing an evidence-base for current guidelines.

2.
Eur Heart J Cardiovasc Imaging ; 24(6): 759-767, 2023 05 31.
Article in English | MEDLINE | ID: mdl-36662130

ABSTRACT

AIMS: Bioprosthetic aortic valve degeneration demonstrates pathological similarities to aortic stenosis. Lipoprotein(a) [Lp(a)] is a well-recognized risk factor for incident aortic stenosis and disease progression. The aim of this study is to investigate whether serum Lp(a) concentrations are associated with bioprosthetic aortic valve degeneration. METHODS AND RESULTS: In a post hoc analysis of a prospective multimodality imaging study (NCT02304276), serum Lp(a) concentrations, echocardiography, contrast-enhanced computed tomography (CT) angiography, and 18F-sodium fluoride (18F-NaF) positron emission tomography (PET) were assessed in patients with bioprosthetic aortic valves. Patients were also followed up for 2 years with serial echocardiography. Serum Lp(a) concentrations [median 19.9 (8.4-76.4) mg/dL] were available in 97 participants (mean age 75 ± 7 years, 54% men). There were no baseline differences across the tertiles of serum Lp(a) concentrations for disease severity assessed by echocardiography [median peak aortic valve velocity: highest tertile 2.5 (2.3-2.9) m/s vs. lower tertiles 2.7 (2.4-3.0) m/s, P = 0.204], or valve degeneration on CT angiography (highest tertile n = 8 vs. lower tertiles n = 12, P = 0.552) and 18F-NaF PET (median tissue-to-background ratio: highest tertile 1.13 (1.05-1.41) vs. lower tertiles 1.17 (1.06-1.53), P = 0.889]. After 2 years of follow-up, there were no differences in annualized change in bioprosthetic hemodynamic progression [change in peak aortic valve velocity: highest tertile [0.0 (-0.1-0.2) m/s/year vs. lower tertiles 0.1 (0.0-0.2) m/s/year, P = 0.528] or the development of structural valve degeneration. CONCLUSION: Serum lipoprotein(a) concentrations do not appear to be a major determinant or mediator of bioprosthetic aortic valve degeneration.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis , Male , Humans , Aged , Aged, 80 and over , Female , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve/pathology , Prospective Studies , Lipoprotein(a) , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography/adverse effects , Heart Valve Prosthesis/adverse effects , Bioprosthesis/adverse effects
3.
Diabetes Metab Syndr Obes ; 15: 2323-2334, 2022.
Article in English | MEDLINE | ID: mdl-35958875

ABSTRACT

Objective: To evaluate the relationship between health literacy, social support, and self-efficacy as predictors of change in A1c and readmission among hospitalized patients with type 2 diabetes (T2D). Methods: This is a secondary analysis of patients with T2D (A1c >8.5%) enrolled in a randomized trial in which health literacy (Newest Vital Sign), social support (Multidimensional Scale of Perceived Social Support), and empowerment (Diabetes Empowerment Scale-Short Form) was assessed at baseline. Multivariable models evaluated whether these concepts were associated with A1c reduction at 12 weeks (absolute change, % with >1% reduction, % reaching individualized target) and readmission (14 and 30 days). Results: A1c (N=108) decreased >1% in 60%, while individualized A1c target was achieved in 31%. After adjustment for baseline A1c and potential confounders, health literacy was associated with significant reduction in A1c (Estimate -0.21, 95% CI -0.40, -0.01, p=0.041) and >1% decrease in A1c (OR 1.37, 95% CI 1.08, 1.73, p=0.009). However, higher social support was associated with greater adjusted odds of reaching the individualized A1c target (OR 1.63, 95% CI 1.04, 2.55, p=0.32). Both higher empowerment (OR 0.23, 95% CI 0.08, 0.64, p=0.005) and social support (OR 0.57, 95% CI 0.36, 0.91, p=0.018) were associated with fewer readmissions by 14 days, but not 30 days. Conclusion: The study indicates that health literacy and social support may be important predictors of A1c reduction post-discharge among hospitalized patients with T2D. Social support and diabetes self-management skills should be addressed and early follow-up may be critical for avoiding readmissions. Clinical Trial: NCT03455985.

4.
JMIR Diabetes ; 7(3): e33401, 2022 Jul 26.
Article in English | MEDLINE | ID: mdl-35881437

ABSTRACT

BACKGROUND: Although the use of electronic order sets has become standard practice for inpatient diabetes management, there is limited decision support at discharge. OBJECTIVE: In this study, we assessed whether an electronic discharge order set (DOS) plus nurse follow-up calls improve discharge orders and postdischarge outcomes among hospitalized patients with type 2 diabetes mellitus. METHODS: This was a randomized, open-label, single center study that compared an electronic DOS and nurse phone calls to enhanced standard care (ESC) in hospitalized insulin-requiring patients with type 2 diabetes mellitus. The primary outcome was change in glycated hemoglobin (HbA1c) level at 24 weeks after discharge. The secondary outcomes included the completeness and accuracy of discharge prescriptions related to diabetes. RESULTS: This study was stopped early because of feasibility concerns related to the long-term follow-up. However, 158 participants were enrolled (DOS: n=82; ESC: n=76), of whom 155 had discharge data. The DOS group had a greater frequency of prescriptions for bolus insulin (78% vs 44%; P=.01), needles or syringes (95% vs 63%; P=.03), and glucometers (86% vs 36%; P<.001). The clarity of the orders was similar. HbA1c data were available for 54 participants in each arm at 12 weeks and for 44 and 45 participants in the DOS and ESC arms, respectively, at 24 weeks. The unadjusted difference in change in HbA1c level (DOS - ESC) was -0.6% (SD 0.4%; P=.18) at 12 weeks and -1.1% (SD 0.4%; P=.01) at 24 weeks. The adjusted difference in change in HbA1c level was -0.5% (SD 0.4%; P=.20) at 12 weeks and -0.7% (SD 0.4%; P=.09) at 24 weeks. The achievement of the individualized HbA1c target was greater in the DOS group at 12 weeks but not at 24 weeks. CONCLUSIONS: An intervention that included a DOS plus a postdischarge nurse phone call resulted in more complete discharge prescriptions. The assessment of postdischarge outcomes was limited, owing to the loss of the long-term follow-up, but it suggested a possible benefit in glucose control. TRIAL REGISTRATION: ClinicalTrials.gov NCT03455985; https://clinicaltrials.gov/ct2/show/NCT03455985.

5.
JACC Cardiovasc Imaging ; 15(6): 1107-1120, 2022 06.
Article in English | MEDLINE | ID: mdl-35033495

ABSTRACT

BACKGROUND: Bioprosthetic valve thrombosis may have implications for valve function and durability. OBJECTIVES: Using a novel glycoprotein IIb/IIIa receptor radiotracer 18F-GP1, we investigated whether positron emission tomography (PET)-computed tomography (CT) could detect thrombus formation on bioprosthetic aortic valves. METHODS: Ex vivo experiments were performed on human platelets and explanted bioprosthetic aortic valves. In a prospective cross-sectional study, patients with either bioprosthetic or normal native aortic valves underwent echocardiography, CT angiography, and 18F-GP1 PET-CT. RESULTS: Flow cytometric analysis, histology, immunohistochemistry, and autoradiography demonstrated selective binding of 18F-GP1 to activated platelet glycoprotein IIb/IIIa receptors and thrombus adherent to prosthetic valves. In total, 75 participants were recruited: 53 with bioprosthetic valves (median time from implantation 37 months [IQR: 12-80 months]) and 22 with normal native aortic valves. Three participants had obstructive valve thrombosis, and a further 3 participants had asymptomatic hypoattenuated leaflet thickening on CT angiography. All bioprosthetic valves, but none of the native aortic valves, demonstrated focal 18F-GP1 uptake on the valve leaflets: median maximum target-to-background ratio 2.81 (IQR: 2.29-3.48) vs 1.43 (IQR: 1.28-1.53) (P < 0.001). Higher 18F-GP1 uptake was independently associated with duration of valve implantation and hypoattenuated leaflet thickening. All 3 participants with obstructive valve thrombosis were anticoagulated for 3 months, leading to resolution of their symptoms, improvement in mean valve gradients, and a reduction in 18F-GP1 uptake. CONCLUSIONS: Adherence of activated platelets is a common and sustained finding on bioprosthetic aortic valves. 18F-GP1 uptake is higher in the presence of thrombus, regresses with anticoagulation, and has potential use as an adjunctive clinical tool. (18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis; NCT04073875).


Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Thrombosis , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Cross-Sectional Studies , Humans , Positron Emission Tomography Computed Tomography , Positron-Emission Tomography , Predictive Value of Tests , Prospective Studies , Thrombosis/diagnostic imaging , Thrombosis/etiology
6.
Endocrinol Diabetes Metab ; 4(3): e00258, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34277982

ABSTRACT

AIMS: This study examined the effect of experimentally-induced hypoglycaemia on measures of myocardial blood flow and myocardial injury in adults with, and without, type 1 diabetes. METHODS: In a prospective, randomised, open-label, blinded, endpoint cross-over study, 17 young adults with type 1 diabetes with no cardiovascular risk factors, and 10 healthy non-diabetic volunteers, underwent hyperinsulinaemic-euglycaemic (blood glucose 4.5-5.5 mmol/L) and hypoglycaemic (2.2-2.5 mmol/L) clamps. Myocardial blood flow was assessed using transthoracic echocardiography Doppler coronary flow reserve (CFR) and myocardial injury using plasma high-sensitivity cardiac troponin I (hs-cTnI) concentration. RESULTS: During hypoglycaemia, coronary flow reserve trended non-significantly lower in those with type 1 diabetes than in the non-diabetic participants (3.54 ± 0.47 vs. 3.89 ± 0.89). A generalised linear mixed-model analysis examined diabetes status and euglycaemia or hypoglycaemia as factors affecting CFR. No statistically significant difference in CFR was observed for diabetes status (p = .23) or between euglycaemia and hypoglycaemia (p = .31). No changes in hs-cTnI occurred during hypoglycaemia or in the recovery period (p = .86). CONCLUSIONS: A small change in CFR was not statistically significant in this study, implying hypoglycaemia may require more than coronary vasomotor dysfunction to cause harm. Further larger studies are required to investigate this putative problem.


Subject(s)
Diabetes Mellitus, Type 1 , Hypoglycemia , Blood Glucose , Cross-Over Studies , Humans , Hypoglycemia/etiology , Prospective Studies , Young Adult
7.
J Cardiovasc Magn Reson ; 23(1): 73, 2021 06 10.
Article in English | MEDLINE | ID: mdl-34107986

ABSTRACT

BACKGROUND: First-phase ejection fraction (EF1; the ejection fraction measured during active systole up to the time of maximal aortic flow) measured by transthoracic echocardiography (TTE) is a powerful predictor of outcomes in patients with aortic stenosis. We aimed to assess whether cardiovascular magnetic resonance (CMR) might provide more precise measurements of EF1 than TTE and to examine the correlation of CMR EF1 with measures of fibrosis. METHODS: In 141 patients with at least mild aortic stenosis, we measured CMR EF1 from a short-axis 3D stack and compared its variability with TTE EF1, and its associations with myocardial fibrosis and clinical outcome (aortic valve replacement (AVR) or death). RESULTS: Intra- and inter-observer variation of CMR EF1 (standard deviations of differences within and between observers of 2.3% and 2.5% units respectively) was approximately 50% that of TTE EF1. CMR EF1 was strongly predictive of AVR or death. On multivariable Cox proportional hazards analysis, the hazard ratio for CMR EF1 was 0.93 (95% confidence interval 0.89-0.97, p = 0.001) per % change in EF1 and, apart from aortic valve gradient, CMR EF1 was the only imaging or biochemical measure independently predictive of outcome. Indexed extracellular volume was associated with AVR or death, but not after adjusting for EF1. CONCLUSIONS: EF1 is a simple robust marker of early left ventricular impairment that can be precisely measured by CMR and predicts outcome in aortic stenosis. Its measurement by CMR is more reproducible than that by TTE and may facilitate left ventricular structure-function analysis.


Subject(s)
Aortic Valve Stenosis , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Humans , Magnetic Resonance Spectroscopy , Predictive Value of Tests , Stroke Volume
8.
Circulation ; 143(25): 2418-2427, 2021 06 22.
Article in English | MEDLINE | ID: mdl-33913339

ABSTRACT

BACKGROUND: Valvular calcification is central to the pathogenesis and progression of aortic stenosis, with preclinical and observational studies suggesting that bone turnover and osteoblastic differentiation of valvular interstitial cells are important contributory mechanisms. We aimed to establish whether inhibition of these pathways with denosumab or alendronic acid could reduce disease progression in aortic stenosis. METHODS: In a single-center, parallel group, double-blind randomized controlled trial, patients >50 years of age with calcific aortic stenosis (peak aortic jet velocity >2.5 m/s) were randomized 2:1:2:1 to denosumab (60 mg every 6 months), placebo injection, alendronic acid (70 mg once weekly), or placebo capsule. Participants underwent serial assessments with Doppler echocardiography, computed tomography aortic valve calcium scoring, and 18F-sodium fluoride positron emission tomography and computed tomography. The primary end point was the calculated 24-month change in aortic valve calcium score. RESULTS: A total of 150 patients (mean age, 72±8 years; 21% women) with calcific aortic stenosis (peak aortic jet velocity, 3.36 m/s [2.93-3.82 m/s]; aortic valve calcium score, 1152 AU [655-2065 AU]) were randomized and received the allocated trial intervention: denosumab (n=49), alendronic acid (n=51), and placebo (injection n=25, capsule n=25; pooled for analysis). Serum C-terminal telopeptide, a measure of bone turnover, halved from baseline to 6 months with denosumab (0.23 [0.18-0.33 µg/L] to 0.11 µg/L [0.08-0.17 µg/L]) and alendronic acid (0.20 [0.14-0.28 µg/L] to 0.09 µg/L [0.08-0.13 µg/L]) but was unchanged with placebo (0.23 [0.17-0.30 µg/L] to 0.26 µg/L [0.16-0.31 µg/L]). There were no differences in 24-month change in aortic valve calcium score between denosumab and placebo (343 [198-804 AU] versus 354 AU [76-675 AU]; P=0.41) or alendronic acid and placebo (326 [138-813 AU] versus 354 AU [76-675 AU]; P=0.49). Similarly, there were no differences in change in peak aortic jet velocity or 18F-sodium fluoride aortic valve uptake. CONCLUSIONS: Neither denosumab nor alendronic acid affected progression of aortic valve calcification in patients with calcific aortic stenosis. Alternative pathways and mechanisms need to be explored to identify disease-modifying therapies for the growing population of patients with this potentially fatal condition. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02132026.


Subject(s)
Alendronate/therapeutic use , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/drug therapy , Bone Density Conservation Agents/therapeutic use , Denosumab/therapeutic use , Disease Progression , Aged , Aged, 80 and over , Aortic Valve Stenosis/metabolism , Double-Blind Method , Female , Humans , Male , Middle Aged , Positron Emission Tomography Computed Tomography , Treatment Outcome , Vascular Calcification/diagnostic imaging , Vascular Calcification/drug therapy , Vascular Calcification/metabolism
9.
BMJ Open ; 10(12): e040200, 2020 12 07.
Article in English | MEDLINE | ID: mdl-33293311

ABSTRACT

INTRODUCTION: Survivors of acute pancreatitis (AP) have shorter overall survival and increased incidence of new-onset cardiovascular, respiratory, liver and renal disease, diabetes mellitus and cancer compared with the general population, but the mechanisms that explain this are yet to be elucidated. Our aim is to characterise the precise nature and extent of organ dysfunction following an episode of AP. METHODS AND ANALYSIS: This is an observational prospective cohort study in a single centre comprising a University hospital with an acute and emergency receiving unit and clinical research facility. Participants will be adult patient admitted with AP. Participants will undergo assessment at recruitment, 3 months and 3 years. At each time point, multiple biochemical and/or physiological assessments to measure cardiovascular, respiratory, liver, renal and cognitive function, diabetes mellitus and quality of life. Recruitment was from 30 November 2017 to 31 May 2020; last follow-up measurements is due on 31 May 2023. The primary outcome measure is the incidence of new-onset type 3c diabetes mellitus during follow-up. Secondary outcome measures include: quality of life analyses (SF-36, Gastrointestinal Quality of Life Index); montreal cognitive assessment; organ system physiological performance; multiomics predictors of AP severity, detection of premature cellular senescence. In a nested cohort within the main cohort, individuals may also consent to multiparameter MRI scan, echocardiography, pulmonary function testing, cardiopulmonary exercise testing and pulse-wave analysis. ETHICS AND DISSEMINATION: This study has received the following approvals: UK IRAS Number 178615; South-east Scotland Research Ethics Committee number 16/SS/0065. Results will be made available to AP survivors, caregivers, funders and other researchers. Publications will be open-access. TRIAL REGISTRATION NUMBERS: ClinicalTrials.gov Registry (NCT03342716) and ISRCTN50581876; Pre-results.


Subject(s)
COVID-19 , Pancreatitis , Acute Disease , Follow-Up Studies , Humans , Prospective Studies , Quality of Life , SARS-CoV-2 , Scotland
10.
Heart ; 106(24): 1906-1913, 2020 12.
Article in English | MEDLINE | ID: mdl-33020228

ABSTRACT

OBJECTIVE: CT quantification of aortic valve calcification (CT-AVC) is useful in the assessment of aortic stenosis severity. Our objective was to assess its ability to track aortic stenosis progression compared with echocardiography. METHODS: Subjects were recruited in two cohorts: (1) a reproducibility cohort where patients underwent repeat CT-AVC or echocardiography within 4 weeks and (2) a disease progression cohort where patients underwent annual CT-AVC and/or echocardiography. Cohen's d-statistic (d) was computed from the ratio of annualised progression and measurement repeatability and used to estimate group sizes required to detect annualised changes in CT-AVC and echocardiography. RESULTS: A total of 33 (age 71±8) and 81 participants (age 72±8) were recruited to the reproducibility and progression cohorts, respectively. Ten CT scans (16%) were excluded from the progression cohort due to non-diagnostic image quality. Scan-rescan reproducibility was excellent for CT-AVC (limits of agreement -12% to 10 %, intraclass correlation (ICC) 0.99), peak velocity (-7% to +17%; ICC 0.92) mean gradient (-25% to 27%, ICC 0.96) and dimensionless index (-11% to +15%; ICC 0.98). Repeat measurements of aortic valve area (AVA) were less reliable (-44% to +28%, ICC 0.85).CT-AVC progressed by 152 (65-375) AU/year. For echocardiography, the median annual change in peak velocity was 0.1 (0.0-0.3) m/s/year, mean gradient 2 (0-4) mm Hg/year and AVA -0.1 (-0.2-0.0) cm2/year. Cohen's d-statistic was more than double for CT-AVC (d=3.12) than each echocardiographic measure (peak velocity d=0.71 ; mean gradient d=0.66; AVA d=0.59, dimensionless index d=1.41). CONCLUSION: CT-AVC is reproducible and demonstrates larger increases over time normalised to measurement repeatability compared with echocardiographic measures.


Subject(s)
Aortic Valve Stenosis/diagnosis , Aortic Valve/diagnostic imaging , Calcium/metabolism , Multidetector Computed Tomography/methods , Aged , Aortic Valve/metabolism , Aortic Valve Stenosis/metabolism , Echocardiography, Doppler , Female , Follow-Up Studies , Humans , Male , Middle Aged , Reproducibility of Results , Retrospective Studies , Severity of Illness Index
11.
Eur Heart J Cardiovasc Imaging ; 21(9): 949-958, 2020 09 01.
Article in English | MEDLINE | ID: mdl-32556199

ABSTRACT

AIMS: To describe the cardiac abnormalities in patients with COVID-19 and identify the characteristics of patients who would benefit most from echocardiography. METHODS AND RESULTS: In a prospective international survey, we captured echocardiography findings in patients with presumed or confirmed COVID-19 between 3 and 20 April 2020. Patient characteristics, indications, findings, and impact of echocardiography on management were recorded. Multivariable logistic regression identified predictors of echocardiographic abnormalities. A total of 1216 patients [62 (52-71) years, 70% male] from 69 countries across six continents were included. Overall, 667 (55%) patients had an abnormal echocardiogram. Left and right ventricular abnormalities were reported in 479 (39%) and 397 (33%) patients, respectively, with evidence of new myocardial infarction in 36 (3%), myocarditis in 35 (3%), and takotsubo cardiomyopathy in 19 (2%). Severe cardiac disease (severe ventricular dysfunction or tamponade) was observed in 182 (15%) patients. In those without pre-existing cardiac disease (n = 901), the echocardiogram was abnormal in 46%, and 13% had severe disease. Independent predictors of left and right ventricular abnormalities were distinct, including elevated natriuretic peptides [adjusted odds ratio (OR) 2.96, 95% confidence interval (CI) 1.75-5.05) and cardiac troponin (OR 1.69, 95% CI 1.13-2.53) for the former, and severity of COVID-19 symptoms (OR 3.19, 95% CI 1.73-6.10) for the latter. Echocardiography changed management in 33% of patients. CONCLUSION: In this global survey, cardiac abnormalities were observed in half of all COVID-19 patients undergoing echocardiography. Abnormalities were often unheralded or severe, and imaging changed management in one-third of patients.


Subject(s)
Cardiovascular Diseases/diagnostic imaging , Cardiovascular Diseases/epidemiology , Coronavirus Infections/epidemiology , Echocardiography/methods , Heart Diseases/diagnostic imaging , Heart Diseases/epidemiology , Pneumonia, Viral/epidemiology , Age Factors , Aged , COVID-19 , Comorbidity , Coronavirus Infections/diagnosis , Cross-Sectional Studies , Europe , Female , Humans , Incidence , Internationality , Internet , Logistic Models , Male , Middle Aged , Multivariate Analysis , Pandemics , Pneumonia, Viral/diagnosis , Predictive Value of Tests , Prognosis , Prospective Studies , Sex Factors
12.
Heart ; 106(16): 1236-1243, 2020 08.
Article in English | MEDLINE | ID: mdl-32345658

ABSTRACT

OBJECTIVE: First-phase ejection fraction (EF1) is a novel measure of early left ventricular systolic dysfunction. We investigated determinants of EF1 and its prognostic value in aortic stenosis. METHODS: EF1 was measured retrospectively in participants of an echocardiography/cardiovascular magnetic resonance cohort study which recruited patients with aortic stenosis (peak aortic velocity of ≥2 m/s) between 2012 and 2014. Linear regression models were constructed to examine variables associated with EF1. Cox proportional hazards were used to determine the prognostic power of EF1 for aortic valve replacement (AVR, performed as part of clinical care in accordance with international guidelines) or death. RESULTS: Total follow-up of the 149 participants (69.8% male, 70 (65-76) years, mean gradient 33 (21-42) mm Hg) was 238 029 person-days. Sixty-seven participants (45%) had a low baseline EF1 (<25%) despite normal ejection fraction (67% (62%-71%)). Patients with low EF1 had more severe aortic stenosis (mean gradient 39 (34-45) mm Hg vs 24 (16-35) mm Hg, p<0.001) and more myocardial fibrosis (indexed extracellular volume (iECV) (24.2 (19.6-28.7) mL/m2 vs 20.6 (16.8-24.3) mL/m2, p=0.002; late gadolinium enhancement (LGE) prevalence 52% vs 20%, p<0.001). Zva, iECV and infarct LGE were independent predictors of EF1. EF1 improved post-AVR (n=57 with post-AVR EF1 available, baseline 16 (12-24) vs follow-up 27% (22%-31%); p<0.001). Low baseline EF1 was an independent predictor of AVR/death (HR 5.6, 95% CI 3.4 to 9.4), driven by AVR. CONCLUSION: EF1 quantifies early, potentially reversible systolic dysfunction in aortic stenosis, is associated with global afterload and myocardial fibrosis, and is an independent predictor of AVR.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Aortic Valve/diagnostic imaging , Echocardiography , Hemodynamics , Stroke Volume , Ventricular Function, Left , Aged , Aortic Valve/pathology , Aortic Valve/physiopathology , Aortic Valve Stenosis/pathology , Aortic Valve Stenosis/physiopathology , Female , Fibrosis , Humans , Magnetic Resonance Imaging, Cine , Male , Middle Aged , Myocardium/pathology , Predictive Value of Tests , Prognosis , Retrospective Studies
13.
Acta Biomater ; 102: 181-191, 2020 01 15.
Article in English | MEDLINE | ID: mdl-31707085

ABSTRACT

The ideal construct for tracheal replacement remains elusive in the management of long segment airway defects. Tissue engineered tracheal grafts (TETG) have been limited by the development of graft stenosis or collapse, infection, or lack of an epithelial lining. We applied a mouse model of orthotopic airway surgery to assess the impact of three critical barriers encountered in clinical applications: the scaffold, the extent of intervention, and the impact of cell seeding and characterized their impact on graft performance. First, synthetic tracheal scaffolds electrospun from polyethylene terephthalate / polyurethane (PET/PU) were orthotopically implanted in anterior tracheal defects of C57BL/6 mice. Scaffolds demonstrated complete coverage with ciliated respiratory epithelium by 2 weeks. Epithelial migration was accompanied by macrophage infiltration which persisted at long term (>6 weeks) time points. We then assessed the impact of segmental tracheal implantation using syngeneic trachea as a surrogate for the ideal tracheal replacement. Graft recovery involved local upregulation of epithelial progenitor populations and there was no evidence of graft stenosis or necrosis. Implantation of electrospun synthetic tracheal scaffold for segmental replacement resulted in respiratory distress and required euthanasia at an early time point. There was limited epithelial coverage of the scaffold with and without seeded bone marrow-derived mononuclear cells (BM-MNCs). We conclude that synthetic scaffolds support re-epithelialization in orthotopic patch implantation, syngeneic graft integration occurs with focal repair mechanisms, however epithelialization in segmental synthetic scaffolds is limited and is not influenced by cell seeding. STATEMENT OF SIGNIFICANCE: The life-threatening nature of long-segment tracheal defects has led to clinical use of tissue engineered tracheal grafts in the last decade for cases of compassionate use. However, the ideal tracheal reconstruction using tissue-engineered tracheal grafts (TETG) has not been clarified. We addressed the core challenges in tissue engineered tracheal replacement (re-epithelialization and graft patency) by defining the role of cell seeding with autologous bone marrow-derived mononuclear cells, the mechanism of respiratory epithelialization and proliferation, and the role of the inflammatory immune response in regeneration. This research will facilitate comprehensive understanding of cellular regeneration and neotissue formation on TETG, which will permit targeted therapies for accelerating re-epithelialization and attenuating stenosis in tissue engineered airway replacement.


Subject(s)
Respiratory Mucosa/metabolism , Tissue Scaffolds/chemistry , Trachea/metabolism , Animals , Bone Marrow Cells/metabolism , Cell Culture Techniques , Female , Mice, Inbred C57BL , Polyethylene Terephthalates/chemistry , Polyurethanes/chemistry , Plastic Surgery Procedures/methods , Tissue Engineering/methods , Trachea/surgery
14.
Echo Res Pract ; 6(4): 105-114, 2019 Dec 01.
Article in English | MEDLINE | ID: mdl-31729209

ABSTRACT

A technology based on velocity ratio indices is described for application in the myocardium. Angle-independent Doppler indices, such as the pulsatility index, which employ velocity ratios, can be measured even if the ultrasound beam vector at the moving target and the motion vector are not in a known plane. The unknown plane situation is often encountered when an ultrasound beam interrogates sites in the myocardium. The velocities employed in an index calculation must be close to the same or opposite directions. The Doppler velocity ratio indices are independent of angle in 3D space as are ratio indices based on 1D strain and 1D speckle tracking. Angle-independent results with spectral Doppler methods are discussed. Possible future imaging techniques based on velocity ratios are presented. By using indices that involve ratios, several other sources of error cancel in addition to that of angular dependence for example errors due to less than optimum gain settings and beam distortion. This makes the indices reliable as research or clinical tools. Ratio techniques can be readily implemented with current commercial blood flow pulsed wave duplex Doppler equipment or with pulsed wave tissue Doppler equipment. In 70 patients where the quality of the real-time B-mode looked suitable for the Doppler velocity ratio technique, there was only one case where clear spectra could not be obtained for both the LV wall and the septum. A reproducibility study of spectra from the septum of the heart shows a 12% difference in velocity ratios in the repeat measurements.

15.
Otolaryngol Head Neck Surg ; 161(3): 458-467, 2019 09.
Article in English | MEDLINE | ID: mdl-31035858

ABSTRACT

OBJECTIVES: Humans receiving tissue-engineered tracheal grafts have experienced poor outcomes ultimately resulting in death or the need for graft explantation. We assessed the performance of the synthetic scaffolds used in humans with an ovine model of orthotopic tracheal replacement, applying standard postsurgical surveillance and interventions to define the factors that contributed to the complications seen at the bedside. STUDY DESIGN: Large animal model. SETTING: Pediatric academic research institute. SUBJECTS AND METHODS: Human scaffolds were manufactured with an electrospun blend of polyethylene terephthalate and polyurethane reinforced with polycarbonate rings. They were seeded with autologous bone marrow-derived mononuclear cells and implanted in sheep. Animals were evaluated with routine bronchoscopy and fluoroscopy. Endoscopic dilation and stenting were performed to manage graft stenosis for up to a 4-month time point. Grafts and adjacent native airway were sectioned and evaluated with histology and immunohistochemistry. RESULTS: All animals had signs of graft stenosis. Three of 5 animals (60%) designated for long-term surveillance survived until the 4-month time point. Graft dilation and stent placement resolved respiratory symptoms and prolonged survival. Necropsy demonstrated evidence of infection and graft encapsulation. Granulation tissue with signs of neovascularization was seen at the anastomoses, but epithelialization was never observed. Acute and chronic inflammation of the native airway epithelium was observed at all time points. Architectural changes of the scaffold included posterior wall infolding and scaffold delamination. CONCLUSIONS: In our ovine model, clinically applied synthetic tissue-engineered tracheas demonstrated infectious, inflammatory, and mechanical failures with a lack of epithelialization and neovascularization.


Subject(s)
Tissue Engineering , Tissue Scaffolds , Trachea/surgery , Animals , Humans , Polyethylene Terephthalates , Polyurethanes , Postoperative Complications/epidemiology , Prosthesis Design , Sheep , Tissue Engineering/methods , Treatment Outcome
16.
J Am Coll Cardiol ; 73(17): 2150-2162, 2019 05 07.
Article in English | MEDLINE | ID: mdl-31047003

ABSTRACT

BACKGROUND: Lipoprotein(a) [Lp(a)], a major carrier of oxidized phospholipids (OxPL), is associated with an increased incidence of aortic stenosis (AS). However, it remains unclear whether elevated Lp(a) and OxPL drive disease progression and are therefore targets for therapeutic intervention. OBJECTIVES: This study investigated whether Lp(a) and OxPL on apolipoprotein B-100 (OxPL-apoB) levels are associated with disease activity, disease progression, and clinical events in AS patients, along with the mechanisms underlying any associations. METHODS: This study combined 2 prospective cohorts and measured Lp(a) and OxPL-apoB levels in patients with AS (Vmax >2.0 m/s), who underwent baseline 18F-sodium fluoride (18F-NaF) positron emission tomography (PET), repeat computed tomography calcium scoring, and repeat echocardiography. In vitro studies investigated the effects of Lp(a) and OxPL on valvular interstitial cells. RESULTS: Overall, 145 patients were studied (68% men; age 70.3 ± 9.9 years). On baseline positron emission tomography, patients in the top Lp(a) tertile had increased valve calcification activity compared with those in lower tertiles (n = 79; 18F-NaF tissue-to-background ratio of the most diseased segment: 2.16 vs. 1.97; p = 0.043). During follow-up, patients in the top Lp(a) tertile had increased progression of valvular computed tomography calcium score (n = 51; 309 AU/year [interquartile range: 142 to 483 AU/year] vs. 93 AU/year [interquartile range: 56 to 296 AU/year; p = 0.015), faster hemodynamic progression on echocardiography (n = 129; 0.23 ± 0.20 m/s/year vs. 0.14 ± 0.20 m/s/year] p = 0.019), and increased risk for aortic valve replacement and death (n = 145; hazard ratio: 1.87; 95% CI: 1.13 to 3.08; p = 0.014), compared with lower tertiles. Similar results were noted with OxPL-apoB. In vitro, Lp(a) induced osteogenic differentiation of valvular interstitial cells, mediated by OxPL and inhibited with the E06 monoclonal antibody against OxPL. CONCLUSIONS: In patients with AS, Lp(a) and OxPL drive valve calcification and disease progression. These findings suggest lowering Lp(a) or inactivating OxPL may slow AS progression and provide a rationale for clinical trials to test this hypothesis.


Subject(s)
Aortic Valve Stenosis/blood , Apolipoprotein B-100/blood , Calcinosis/complications , Disease Progression , Lipoprotein(a)/blood , Phospholipids/blood , Age Factors , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/pathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/etiology , Biomarkers/blood , Calcinosis/blood , Cohort Studies , Echocardiography, Doppler/methods , Female , Humans , Hyperlipidemias/blood , Hyperlipidemias/complications , Hyperlipidemias/mortality , Male , Middle Aged , Positron-Emission Tomography/methods , Prognosis , Proportional Hazards Models , Prospective Studies , Risk Assessment , Sex Factors , Survival Analysis , Tomography, X-Ray Computed/methods
17.
J Vis Exp ; (146)2019 04 01.
Article in English | MEDLINE | ID: mdl-30985752

ABSTRACT

Treatment options for congenital or secondary long segment tracheal defects have historically been limited due to an inability to replace functional tissue. Tissue engineering holds great promise as a potential solution with its ability to integrate cells and signaling molecules into a 3-dimensional scaffold. Recent work with tissue engineered tracheal grafts (TETGs) has seen some success but their translation has been limited by graft stenosis, graft collapse, and delayed epithelialization. In order to investigate the mechanisms driving these issues, we have developed a mouse model for tissue engineered tracheal graft implantation. TETGs were constructed using electrospun polymers polyethylene terephthalate (PET) and polyurethane (PU) in a mixture of PET and PU (20:80 percent weight). Scaffolds were then seeded using bone marrow mononuclear cells isolated from 6-8 week-old C57BL/6 mice by gradient centrifugation. Ten million cells per graft were seeded onto the lumen of the scaffold and allowed to incubate overnight before implantation between the third and seventh tracheal rings. These grafts were able to recapitulate the findings of stenosis and delayed epithelialization as demonstrated by histological analysis and lack of Keratin 5 and Keratin 14 basal epithelial cells on immunofluorescence. This model will serve as a tool for investigating cellular and molecular mechanisms involved in host remodeling.


Subject(s)
Tissue Engineering/methods , Trachea/transplantation , Animals , Constriction, Pathologic/pathology , Epithelial Cells/cytology , Mice, Inbred C57BL , Models, Animal , Polyethylene Terephthalates/chemistry , Tissue Scaffolds/chemistry
18.
J Am Coll Cardiol ; 73(10): 1107-1119, 2019 03 19.
Article in English | MEDLINE | ID: mdl-30871693

ABSTRACT

BACKGROUND: Bioprosthetic aortic valve degeneration is increasingly common, often unheralded, and can have catastrophic consequences. OBJECTIVES: The authors sought to assess whether 18F-fluoride positron emission tomography (PET)-computed tomography (CT) can detect bioprosthetic aortic valve degeneration and predict valve dysfunction. METHODS: Explanted degenerate bioprosthetic valves were examined ex vivo. Patients with bioprosthetic aortic valves were recruited into 2 cohorts with and without prosthetic valve dysfunction and underwent in vivo contrast-enhanced CT angiography, 18F-fluoride PET, and serial echocardiography during 2 years of follow-up. RESULTS: All ex vivo, degenerate bioprosthetic valves displayed 18F-fluoride PET uptake that colocalized with tissue degeneration on histology. In 71 patients without known bioprosthesis dysfunction, 14 had abnormal leaflet pathology on CT, and 24 demonstrated 18F-fluoride PET uptake (target-to-background ratio 1.55 [interquartile range (IQR): 1.44 to 1.88]). Patients with increased 18F-fluoride uptake exhibited more rapid deterioration in valve function compared with those without (annualized change in peak transvalvular velocity 0.30 [IQR: 0.13 to 0.61] vs. 0.01 [IQR: -0.05 to 0.16] ms-1/year; p < 0.001). Indeed 18F-fluoride uptake correlated with deterioration in all the conventional echocardiographic measures of valve function assessed (e.g., change in peak velocity, r = 0.72; p < 0.001). Each of the 10 patients who developed new overt bioprosthesis dysfunction during follow-up had evidence of 18F-fluoride uptake at baseline (target-to-background ratio 1.89 [IQR: 1.46 to 2.59]). On multivariable analysis, 18F-fluoride uptake was the only independent predictor of future bioprosthetic dysfunction. CONCLUSIONS: 18F-fluoride PET-CT identifies subclinical bioprosthetic valve degeneration, providing powerful prediction of subsequent valvular dysfunction and highlighting patients at risk of valve failure. This technique holds major promise in the diagnosis of valvular degeneration and the surveillance of patients with bioprosthetic valves. (18F-Fluoride Assessment of Aortic Bioprosthesis Durability and Outcome [18F-FAABULOUS]; NCT02304276).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis/surgery , Aortic Valve , Bioprosthesis , Heart Valve Prosthesis , Positron Emission Tomography Computed Tomography/methods , Postoperative Complications , Prosthesis Failure/adverse effects , Aged , Aortic Valve/physiopathology , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnosis , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/diagnosis , Calcinosis/diagnosis , Calcinosis/etiology , Computed Tomography Angiography/methods , Echocardiography/methods , Female , Fluorodeoxyglucose F18/pharmacology , Humans , Male , Postoperative Complications/diagnosis , Postoperative Complications/etiology , Predictive Value of Tests , Prognosis , Radiopharmaceuticals/pharmacology
19.
Radiol Cardiothorac Imaging ; 1(4): e190027, 2019 Oct.
Article in English | MEDLINE | ID: mdl-33778518

ABSTRACT

PURPOSE: To use global longitudinal strain (GLS) as a marker of left ventricular decompensation in aortic stenosis and to investigate the relationship of GLS measured with cardiac MRI with markers of myocardial fibrosis, symptom development, remodeling, and clinical outcomes. MATERIALS AND METHODS: Patients with aortic stenosis and healthy control subjects were assessed. GLS was assessed by using cardiac MRI feature tracking, diffuse fibrosis by T1 mapping, and replacement fibrosis using late gadolinium enhancement. Follow-up was prospective for the primary endpoint of all-cause mortality. RESULTS: GLS was reduced in aortic stenosis (n = 159) compared with control subjects (n = 41) (-17.6% ± 3.1 [standard deviation] vs -18.9% ± 2.6, P = .02). GLS demonstrated weak associations with aortic stenosis severity (Vmax; r = 0.24, P = .0005) but showed moderate correlation with T1 mapping measures of myocardial fibrosis (eg, indexed extracellular volume [iECV]; r = 0.43, P < .0001). Moreover, GLS was reduced in patients with midwall fibrosis compared with control subjects (P < .001), although values were similar to those of patients with myocardial infarction (P = .25). In adjusted analyses, GLS was associated with total myocardial fibrosis burden (iECV) and ejection fraction (both P < .001). GLS offered poor discrimination between disease states, inability to distinguish between control subjects and patients (area under the curve [AUC], 0.60), presence or absence of fibrosis (AUC, 0.63), or symptomatic severity (left ventricular decompensation AUC, 0.64). At follow-up (median, 1466 days), 21 patients died. GLS did not independently predict clinical outcomes. CONCLUSION: GLS correlates with established markers of myocardial fibrosis. However, widespread utility of single GLS measurements may be limited by overlap between disease states and its inability to predict clinical outcomes beyond current established markers.© RSNA, 2019Supplemental material is available for this article.

20.
Circ Cardiovasc Imaging ; 11(6): e007451, 2018 06.
Article in English | MEDLINE | ID: mdl-29914867

ABSTRACT

BACKGROUND: Aortic stenosis is accompanied by progressive left ventricular hypertrophy and fibrosis. We investigated the natural history of these processes in asymptomatic patients and their potential reversal post-aortic valve replacement (AVR). METHODS: Asymptomatic and symptomatic patients with aortic stenosis underwent repeat echocardiography and magnetic resonance imaging. Changes in peak aortic-jet velocity, left ventricular mass index, diffuse fibrosis (indexed extracellular volume), and replacement fibrosis (late gadolinium enhancement [LGE]) were quantified. RESULTS: In 61 asymptomatic patients (43% mild, 34% moderate, and 23% severe aortic stenosis), significant increases in peak aortic-jet velocity, left ventricular mass index, indexed extracellular volume, and LGE mass were observed after 2.1±0.7 years, with the most rapid progression observed in patients with most severe stenosis. Patients with baseline midwall LGE (n=16 [26%]; LGE mass, 2.5 g [0.8-4.8 g]) demonstrated particularly rapid increases in scar burden (78% [50%-158%] increase in LGE mass per year). In 38 symptomatic patients (age, 66±8 years; 76% men) who underwent AVR, there was a 19% (11%-25%) reduction in left ventricular mass index (P<0.0001) and an 11% (4%-16%) reduction in indexed extracellular volume (P=0.003) 0.9±0.3 years after surgery. By contrast midwall LGE (n=10 [26%]; mass, 3.3 g [2.6-8.0 g]) did not change post-AVR (n=10; 3.5 g [2.1-8.0 g]; P=0.23), with no evidence of regression even out to 2 years. CONCLUSIONS: In patients with aortic stenosis, cellular hypertrophy and diffuse fibrosis progress in a rapid and balanced manner but are reversible after AVR. Once established, midwall LGE also accumulates rapidly but is irreversible post valve replacement. Given its adverse long-term prognosis, prompt AVR when midwall LGE is first identified may improve clinical outcomes. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifiers: NCT01755936 and NCT01679431.


Subject(s)
Aortic Valve Stenosis/diagnostic imaging , Hypertrophy, Left Ventricular/diagnostic imaging , Magnetic Resonance Imaging , Myocardium/pathology , Ventricular Function, Left , Ventricular Remodeling , Aged , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/physiopathology , Aortic Valve Stenosis/surgery , Contrast Media/administration & dosage , Disease Progression , Echocardiography , Female , Fibrosis , Heart Valve Prosthesis Implantation , Humans , Hypertrophy, Left Ventricular/etiology , Hypertrophy, Left Ventricular/pathology , Hypertrophy, Left Ventricular/physiopathology , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Quebec , Scotland , Severity of Illness Index , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...