Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Angew Chem Int Ed Engl ; 63(35): e202408792, 2024 Aug 26.
Article in English | MEDLINE | ID: mdl-38850105

ABSTRACT

The abnormal fluctuation of temperature in vivo usually reflects the progression of inflammatory diseases. Noninvasive, real-time, and accurate monitoring and imaging of temperature variation in vivo is advantageous for guiding the early diagnosis and treatment of disease, but it remains difficult to achieve. Herein, we developed a temperature-activated near-infrared-II fluorescence (NIR-II FL) and surface-enhanced Raman scattering (SERS) nanoprobe for long-term monitoring of temperature changes in rat arthritis and timely assessment of the status of osteoarthritis. The thermosensitive polymer bearing NIR-II FL dye was grafted onto the surface of nanoporous core-satellite gold nanostructures to form the nanoprobe, wherein the nanoprobe contains NIR-II FL and Raman reference signals that are independent of temperature change. The ratiometric FL1150/FL1550 and S1528/S2226 values of the nanoprobe exhibited a reversible conversion with temperature changes. The nanoprobe accurately distinguishes the temperature variations in the inflamed joint versus the normal joint in vivo by ratiometric FL and SERS imaging, allowing for an accurate diagnosis of inflammation. Meanwhile, it can continuously monitor fluctuations in temperature over an extended period during the onset and treatment of inflammation. The tested temperature change trend could be used as an indicator for early diagnosis of inflammation and real-time evaluation of therapeutic effects.


Subject(s)
Fluorescent Dyes , Gold , Osteoarthritis , Spectrum Analysis, Raman , Temperature , Animals , Rats , Osteoarthritis/diagnostic imaging , Fluorescent Dyes/chemistry , Gold/chemistry , Metal Nanoparticles/chemistry , Infrared Rays , Fluorescence , Surface Properties
2.
Small ; 19(11): e2206666, 2023 03.
Article in English | MEDLINE | ID: mdl-36534901

ABSTRACT

Optical imaging in the second near-infrared (NIR-II, 900-1700 nm) window has been extensively investigated for bioimaging. However, a strong autofluorescence background from real-time excitation light significantly reduces the images' quality of NIR-II fluorescence (FL) imaging. To resolve this issue, a NIR-II self-luminous small molecule (CLPD) based on bioluminescence (BL) resonance energy transfer (BRET) mechanism is first developed. The reactive oxygen species (ROS) can trigger NIR-II BL and reduce the NIR-II FL signals of the CLPD simultaneously, enabling ROS-correlated ratiometric BL/FL imaging. CLPD is used for high-contrast NIR-II BL imaging of osteoarthritis as well as guiding the treatment process by ratiometric BL/FL imaging. Moreover, CLPD is applied for NIR-II BL imaging of tumor triggered by the generated ROS during PDT. A correlation between the ratiometric NIR-II BL/FL signal and tumor size is constructed, providing a trustworthy tool for early assessment of PDT effect. Overall, this study presents a novel NIR-II self-luminous small molecular probe for in vivo imaging and provides a strategy for design a self-evaluation system of therapeutic effect.


Subject(s)
Molecular Probes , Neoplasms , Humans , Reactive Oxygen Species , Neoplasms/diagnostic imaging , Neoplasms/therapy , Inflammation
3.
Anal Chem ; 94(30): 10797-10804, 2022 08 02.
Article in English | MEDLINE | ID: mdl-35829734

ABSTRACT

Metformin is commonly used for clinical treatment of type-2 diabetes, but long-term or overdose intake of metformin usually causes selective upregulation of H2S level in the liver, resulting in liver injury. Therefore, tracking the changes of H2S content in the liver would contribute to the prevention and diagnosis of liver injury. However, in the literature, there are few reports on ratiometric PA molecular probes for H2S detection in drug-induced liver injury (DILI). Accordingly, here we developed a H2S-activated ratiometric PA probe, namely BDP-H2S, based Aza-BODIPY dye for detecting the H2S upregulation of metformin-induced liver injury. Due to the intramolecular charge transfer (ICT) effect, BDP-H2S exhibited a strong PA signal at 770 nm. Following the response to H2S, its ICT effect was recovered which showed a decrement of PA770 and an enhancement of PA840. The ratiometric PA signal (PA840/PA770) showed excellent H2S selectivity response with a low limit of detection (0.59 µM). Bioimaging experiments demonstrated that the probe has been successfully used for ratiometric PA imaging of H2S in cells and metformin-induced liver injury in mice. Overall, the designed probe emerges as a powerful tool for noninvasive and accurate imaging of H2S level and tracking its distribution and variation in liver in-real time.


Subject(s)
Chemical and Drug Induced Liver Injury, Chronic , Hydrogen Sulfide , Metformin , Photoacoustic Techniques , Animals , Fluorescent Dyes/pharmacology , Mice , Photoacoustic Techniques/methods
SELECTION OF CITATIONS
SEARCH DETAIL