Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Phytomedicine ; 123: 155259, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38096718

ABSTRACT

BACKGROUND: Scutellaria baicalensis Georgi, a traditional Chinese medicine, is clinically applied mainly as the dried root of Scutellaria baicalensis, and the aerial parts of Scutellaria baicalensis, its stems and leaves, are often consumed as "Scutellaria baicalensis tea" to clear heat, dry dampness, reduce fire and detoxify, while few comparative analyses of the spatial metabolome of the aerial and underground parts of Scutellaria baicalensis have been carried out in current research. METHODS: In this work, Matrix-assisted laser desorption ionization-mass spectrometry imaging (MALDI-MSI) was used to visualize the spatial imaging of the root, stem, and leaf of Scutellaria baicalensis at a high resolution of 10 µm, respectively, investigating the spatial distribution of the different secondary metabolites in the aerial and underground parts of Scutellaria baicalensis. RESULTS: In the present results, various metabolites, such as flavonoid glycosides, flavonoid metabolites, and phenolic acids, were systematically characterized in Scutellaria baicalensis root, stem, and leaf. Nine glycosides, 18 flavonoids, one organic acid, and four other metabolites in Scutellaria baicalensis root; nine glycosides, nine flavonoids, one organic acid in Scutellaria baicalensis stem; and seven flavonoids and seven glycosides in Scutellaria baicalensis leaf were visualized by MALDI-MSI. In the underground part of Scutellaria baicalensis, baicalein, wogonin, baicalin, wogonoside, and chrysin were widely distributed, while there was less spatial location in the aerial parts. Moreover, scutellarein, carthamidin/isocarthamidin, scutellarin, carthamidin/isocarthamidin-7-O-glucuronide had a high distribution in the aerial parts of Scutellaria baicalensis. In addition, the biosynthetic pathways involved in the biosynthesis of significant flavonoid metabolites in aerial and underground parts of Scutellaria baicalensis were successfully localized and visualized. CONCLUSIONS: MALDI-MSI offers a favorable approach for investigating the spatial distribution and effective utilization of metabolites of Scutellaria baicalensis. The detailed spatial chemical information can not only improve our understanding of the biosynthesis pathways of flavonoid metabolites, but more importantly, suggest that we need to fully exert the overall medicinal value of Scutellaria baicalensis, strengthening the reuse and development of the resources of Scutellaria baicalensis aboveground parts.


Subject(s)
Flavonoids , Scutellaria baicalensis , Scutellaria baicalensis/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Flavonoids/analysis , Glycosides/analysis , Metabolome , Lasers , Plant Roots/chemistry
2.
Bioengineering (Basel) ; 10(9)2023 Sep 12.
Article in English | MEDLINE | ID: mdl-37760181

ABSTRACT

Quadrupole mass spectrometers (QMS) are widely used for clinical diagnosis and chemical analysis. To obtain the best experimental results, mass spectrometers must be calibrated to an ideal setting before use. However, tuning the current QMS is challenging. Traditional tuning techniques possess low automation levels and rely primarily on skilled engineers. Therefore, in this study, we propose an innovative auto-tuning algorithm for QMS based on the improved particle swarm optimization (PSO) algorithm to automatically find the optimal solution of QMS parameters and make the QMS reach the optimal state. The improved PSO algorithm is combined with simulated annealing, multiple inertia weights, dynamic boundaries, and other methods to prevent the traditional PSO algorithm from the issue of a local optimal solution and premature convergence. According to the characteristics of the mass spectrum peaks, a termination function is proposed to simplify the termination conditions of the PSO algorithm and further improve the automation level of the mass spectrometer. The results of auto-calibration testing of resolution and mass axis show that both resolution and mass axis calibration could effectively meet the requirements of mass spectrometry experiments. By the experiment of auto-optimization testing of lens and ion source parameters, these parameters were all in the vicinity of the optimal solution, which achieved the expected performance. Through numerous experiments, the reproducibility of the algorithm was established as meeting the auto-tuning function of the QMS. The proposed method can automatically tune the mass spectrometer from its non-optimal condition to the optimal one, which can effectively reduce the tuning difficulty of QMS.

SELECTION OF CITATIONS
SEARCH DETAIL
...