Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Language
Publication year range
1.
Braz J Anesthesiol ; 71(5): 565-571, 2021.
Article in English | MEDLINE | ID: mdl-33895220

ABSTRACT

BACKGROUND AND OBJECTIVES: With the intensive study of lung protective ventilation strategies, people begin to advocate the individualized application of positive end-expiratory pressure (PEEP). This study investigated the optimal PEEP in patients during one-lung ventilation (OLV) and its effects on pulmonary mechanics and oxygenation. METHODS: Fifty-eight patients who underwent elective thoracoscopic lobectomy were randomly divided into two groups. Both groups received an alveolar recruitment maneuver (ARM) after OLV. Patients in Group A received optimal PEEP followed by PEEP decremental titration, while Group B received standard 5 cmH2O PEEP until the end of OLV. Relevant indexes of respiratory mechanics, pulmonary oxygenation and hemodynamics were recorded after entering the operating room (T0), 10 minutes after intubation (T1), pre-ARM (T2), 20 minutes after the application of optimal PEEP (T3), at the end of OLV (T4) and at the end of surgery (T5). Postoperative outcomes were also assessed. RESULTS: The optimal PEEP obtained in Group A was 8.8 ± 2.4 cmH2O, which positively correlated with BMI and forced vital capacity (FVC). Group A had a higher CPAT than Group B at T3, T4, T5 (p < 0.05) and a smaller ΔP than Group B at T3, T4 (p < 0.01). At T4, PaO2 was significantly higher in Group A (p < 0.01). At T3, stroke volume variation was higher in Group A (p < 0.01). Postoperative outcomes did not differ between the two groups. CONCLUSIONS: Our findings suggest that the individualized PEEP can increase lung compliance, reduce driving pressure, and improve pulmonary oxygenation in patients undergoing thoracoscopic lobectomy, with little effect on hemodynamics.


Subject(s)
One-Lung Ventilation , Positive-Pressure Respiration , Humans , Lung Compliance , Respiratory Mechanics , Tidal Volume
2.
Genet. mol. biol ; Genet. mol. biol;27(2): 284-290, Jun. 2004. ilus, tab, graf
Article in English | LILACS | ID: lil-362903

ABSTRACT

To identify the specificity of base substitutions, a novel experimental system was established based on rifampicin-resistant (Rif r) mutant screening and sequencing of the defined region of the rpoB gene in E. coli. We focused on comparing mutational spectra of base substitutions induced by either low energy nitrogen ion beam implantation or 60Co-gamma rays. The most significant difference in the frequency of specific kinds of mutations induced by low energy nitrogen ion beam was that CG -> TA transitions were significantly increased from 32 to 46, AT -> TA transversions were doubled from 7 to 15 in 50 mutants, respectively. The preferential base substitutions induced by nitrogen ion beam implantation were CG -> TA transitions, AT -> GC transitions, AT -> TA transversions, which account for 92.13 percent (82/89) of the total. The mutations induced by 60Co-gamma rays were preferentially GC -> AT and AT -> GC transitions, which totaled 84.31 percent (43/51).


Subject(s)
Escherichia coli , Gamma Rays , Rifampin , Ions , Mutation , Seeds
SELECTION OF CITATIONS
SEARCH DETAIL