Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 159
1.
Am J Cardiol ; 2024 May 24.
Article En | MEDLINE | ID: mdl-38797196

The hemodynamic performance of self-expandable valves (SEVs) is a preferable choice for small aortic annuli in transcatheter aortic valve replacement (TAVR). However, no data are, so far, available regarding the relation between the size of SEVs and clinical outcomes. This study aimed to evaluate the impact of prosthesis size on adverse events after TAVR using SEVs. We retrospectively analyzed 1,400 patients (23-mm SEV: 13.6%) who underwent TAVR using SEVs at 12 centers. The impact of SEV size on all-cause death and heart failure (HF) after TAVR was evaluated by multivariate Cox regression and propensity score (PS) matching analysis. During the follow-up period (median 511 days), 201 all-cause deaths and 87 HF rehospitalizations were observed. The incidence of all-cause death was comparable between small- (23-mm SEV) and larger-sized (26- or 29-mm SEV) (16.8% vs 13.9%, log-rank p = 0.29). The size of SEV was not associated with a higher incidence of all-cause death (hazard ratio [HR] 1.21, 95% confidence interval [CI] 0.79 to 1.86 in Cox regression; HR 1.31, 95% CI 0.77 to 2.23 in PS matching) and HF after TAVR (subdistribution HR 0.79, 95% CI 0.37 to 1.72 in Cox regression; subdistribution HR 1.00, 95% CI 0.44 to 2.30 in PS matching). The multivariate model including postprocedural prosthesis-patient mismatch showed consistent results. In conclusion, small SEVs had comparable midterm clinical outcomes to larger-sized SEVs, even if the prosthesis-patient mismatch was observed after TAVR.

2.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Article En | MEDLINE | ID: mdl-38726714

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Aortic Valve Stenosis , Aortic Valve , Heart Valve Prosthesis , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/methods , Female , Male , Aged, 80 and over , Aged , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/physiopathology , Treatment Outcome , Aortic Valve/surgery , Aortic Valve/physiopathology , Aortic Valve/diagnostic imaging , Prosthesis Design , Hemodynamics , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Hospital Mortality
3.
JACC Asia ; 4(4): 306-319, 2024 Apr.
Article En | MEDLINE | ID: mdl-38660100

Background: Few reports on pre-existing left bundle branch block (LBBB) in patients undergoing transcatheter aortic valve replacement (TAVR) are currently available. Further, no present studies compare patients with new onset LBBB with those with pre-existing LBBB. Objectives: This study aimed to investigate the association between pre-existing or new onset LBBB and clinical outcomes after TAVR. Methods: Using data from the Japanese multicenter registry, 5,996 patients who underwent TAVR between October 2013 and December 2019 were included. Patients were classified into 3 groups: no LBBB, pre-existing LBBB, and new onset LBBB. The 2-year clinical outcomes were compared between 3 groups using Cox proportional hazards models and propensity score analysis to adjust the differences in baseline characteristics. Results: Of 5,996 patients who underwent TAVR, 280 (4.6%) had pre-existing LBBB, while 1,658 (27.6%) experienced new onset LBBB. Compared with the no LBBB group, multivariable Cox regression analysis showed that pre-existing LBBB was associated not only with a higher 2-year all-cause (adjusted HR: 1.39; 95% CI: 1.06-1.82; P = 0.015) and cardiovascular (adjusted HR: 1.60; 95% CI: 1.04-2.48; P = 0.031) mortality, but also with higher all-cause (adjusted HR: 1.43, 95% CI: 1.07-1.91; P = 0.016) and cardiovascular (adjusted HR: 1.81, 95% CI:1.12-2.93; P = 0.014) mortality than the new onset LBBB group. Heart failure was the most common cause of cardiovascular death, with more heart failure deaths in the pre-existing LBBB group. Conclusions: Pre-existing LBBB was independently associated with poor clinical outcomes, reflecting an increased risk of cardiovascular mortality after TAVR. Patients with pre-existing LBBB should be carefully monitored.

4.
ESC Heart Fail ; 2024 Apr 12.
Article En | MEDLINE | ID: mdl-38607328

AIMS: A considerable proportion of candidates for transcatheter aortic valve implantation (TAVI) have underlying heart failure (HF) with preserved ejection fraction (HFpEF), which can be challenging for diagnosis because significant valvular heart disease should be excluded before diagnosing HFpEF. This study investigated the long-term prognostic value of the pre-procedural H2FPEF score in patients with preserved ejection fraction (EF) undergoing TAVI. METHODS AND RESULTS: Patients who underwent TAVI between October 2013 and May 2017 were enrolled from the Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation Japanese multicentre registry. After excluding 914 patients, 1674 patients with preserved EF ≥ 50% (median age: 85 years, 72% female) were selected for calculation of the H2FPEF score and were dichotomized into two groups: the low H2FPEF score [0-5 points; n = 1399 (83.6%)] group and the high H2FPEF score [6-9 points; n = 275 (16.4%)] group. Patients with high H2FPEF scores were associated with a higher prevalence of New York Heart Association Functional Class III/IV (59.3% vs. 43.7%, P < 0.001), diabetes (24.4% vs. 18.5%, P = 0.03), and paradoxical low-flow, low-gradient aortic stenosis (15.9% vs. 6.2%, P < 0.001). These patients showed worse prognoses than those with low H2FPEF scores regarding the cumulative 2 year all-cause mortality (26.3% vs. 15.5%, log-rank P < 0.001), cardiovascular mortality (10.5% vs. 5.4%, log-rank P < 0.001), HF hospitalization (16.2% vs. 6.7%, log-rank P < 0.001), and the composite endpoint of cardiovascular mortality and HF hospitalization (23.8% vs. 10.8%, log-rank P < 0.001). After adjustment for several confounders, the high H2FPEF scores were independently associated with increased risk for all-cause mortality [adjusted hazard ratio (HR), 1.48; 95% confidence interval (CI), 1.09-2.00; P = 0.011] and for the composite endpoint of cardiovascular mortality and HF hospitalization (adjusted HR, 1.95; 95% CI, 1.38-2.74; P < 0.001). Subgroup analysis confirmed the excess risk of high H2FPEF scores relative to low H2FPEF scores for the composite endpoint of cardiovascular mortality and HF hospitalization increased with a lower Society of Thoracic Surgeons (STS) score (STS score <8%: adjusted HR, 2.40; 95% CI, 1.50-3.85; P < 0.001; STS score ≥8%: adjusted HR, 1.34; 95% CI, 0.79-2.28; P = 0.28; Pinteraction = 0.030). CONCLUSIONS: The H2FPEF score is useful for predicting long-term adverse outcomes after TAVI, including all-cause mortality, cardiovascular mortality, and HF hospitalization for patients with preserved EF. More aggressive interventions targeting HFpEF in addition to the TAVI procedure might be relevant in patients with high H2FPEF scores, particularly in those with a lower surgical risk.

6.
Open Heart ; 11(1)2024 Feb 27.
Article En | MEDLINE | ID: mdl-38417913

OBJECTIVES: The clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with aortic stenosis (AS) and concomitant active cancer remain insufficiently explored. This study aimed to assess the midterm outcomes of TAVR in patients diagnosed with AS and active cancer. METHODS: Data from the OCEAN-TAVI, a prospective Japanese registry of TAVR procedures, was analysed to compare prognoses and clinical outcomes in patients with and without active cancer at the time of TAVR. RESULTS: Of the 2336 patients who underwent TAVR from October 2013 to July 2017, 89 patients (3.8%) had active cancer, whereas 2247 did not. Among patients with active cancer, 49 had limited-stage cancer (stage 1 or 2). The prevalent cancers identified before TAVR were colon (21%), prostate (18%), lung (15%), liver (11%) and breast (9%). Although the periprocedural complications and 30-day mortality rates were comparable between the groups, the 3-year survival rate after TAVR was notably lower in patients with active cancer (64.7%) than in those without active cancer (74.7%; p=0.016). Nevertheless, the 3-year survival rate of patients with limited-stage cancer (stage 1 or 2) did not significantly differ from those without cancer (70.6% vs 74.7%, p=0.50). CONCLUSIONS: The patients with active cancer exhibited significantly reduced midterm survival rates. However, no distinct disparity existed in those with limited-stage cancer (stage 1 or 2). Although TAVR is a viable treatment in patients with AS with active cancer, the type and stage of cancer and prognosis should be carefully weighed in the decision-making process.


Aortic Valve Stenosis , Neoplasms , Transcatheter Aortic Valve Replacement , Male , Humans , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Prospective Studies , Time Factors , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Neoplasms/diagnosis
7.
Am J Cardiol ; 214: 47-54, 2024 Mar 01.
Article En | MEDLINE | ID: mdl-38215815

Sodium-glucose cotransporter-2 inhibitors (SGLT2is) are widely used in cardiology and are effective in treating acute coronary syndrome (ACS). Their effects on unstable plaque in patients with ACS remains unclear. This study aimed to examine the effectiveness of SGLT2is in coronary plaque based on optical coherence tomography (OCT) images and the prognosis of ACS with type 2 diabetes mellitus. This retrospective study included 109 patients in the total cohort and 29 patients in the OCT cohort. Based on SGLT2i administration after ACS, the total cohort was categorized into non-SGLT2i (n = 69) and SGLT2i (n = 40) groups. The OCT cohort had 15 and 14 patients in the non-SGLT2i and SGLT2i groups, respectively. The OCT images of unstable plaque were analyzed in nonstented lesions during ACS catheterization and at the 6-month follow-up. The total cohort was assessed after 1 year for major adverse cardiovascular events, including all-cause mortality, revascularization, cerebrovascular disease, and heart failure hospitalization. SGLT2is improved unstable lesions with a significantly thicker fibrous cap (48 ± 15 µm vs 26 ± 24 µm, p = 0.005), reduced lipid arc (-29 ± 12° vs -18 ± 14°, p = 0.028), higher % decrease in total lipid arc (-35 ± 13% vs -19 ± 18%, p = 0.01), and lower major adverse cardiovascular event incidence (log-rank p = 0.023, hazard ratio 4.72 [1.08 to 20.63]) and revascularization rate (adjusted hazard ratio 6.77 [1.08 to 42.52]) than the non-SGLT2i group. In conclusion, SGLT2is can improve the markers of plaque stability and may improve the prognosis in patients with type 2 diabetes mellitus.


Acute Coronary Syndrome , Diabetes Mellitus, Type 2 , Plaque, Atherosclerotic , Sodium-Glucose Transporter 2 Inhibitors , Humans , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/drug therapy , Acute Coronary Syndrome/epidemiology , Sodium-Glucose Transporter 2 Inhibitors/therapeutic use , Diabetes Mellitus, Type 2/complications , Diabetes Mellitus, Type 2/drug therapy , Retrospective Studies , Plaque, Atherosclerotic/complications , Plaque, Atherosclerotic/diagnostic imaging , Plaque, Atherosclerotic/drug therapy , Glucose , Lipids , Sodium
8.
Circ J ; 88(4): 462-471, 2024 Mar 25.
Article En | MEDLINE | ID: mdl-38030300

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis (AS), but despite estimates of life expectancy after TAVI being essential in heart team discussion, these data are scarce. Therefore, the current study sought to assess long-term survival and its trends in relation to chronological age, surgical risk, and treatment period.Methods and Results: We included 2,414 consecutive patients who underwent TAVI for severe symptomatic AS between 2008 and 2021 at 2 international centers. For the analysis, long-term survival was evaluated according to age, surgical risk, and treatment period categorized into 3 groups, respectively. The longest follow-up was 13.5 years. Overall survival was 67.6% at 5 years and 26.9% at 10 years. Younger patients, lower surgical risk, and later treatment period showed better survival (log-rank P<0.001, respectively). In the multivariate analysis, age <75years, lower surgical risk, and later time period were significantly associated with better survival. The incidence of paravalvular leakage ≥moderate, red blood cell transfusion, and acute kidney injury were independently associated with increasing risk of 5-year death. CONCLUSIONS: In a real-world registry, survival was substantial following TAVI, especially in younger and lower surgical-risk patients, with improving outcomes over time. This should be considered in heart team discussions of life-long management for AS patients after TAVI.


Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/surgery , Treatment Outcome , Risk Factors , Heart Valve Prosthesis Implantation/adverse effects , Registries
9.
Am J Cardiol ; 213: 151-160, 2024 Feb 15.
Article En | MEDLINE | ID: mdl-38103766

Preexisting right bundle branch block (RBBB) is the strongest predictor for permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI). However, the risk assessment for new PPI and effective procedural strategy for preventing new PPI in patients with preexisting RBBB are still unclear. This study stratified the new PPI risk after TAVI and investigated the impact of implantation strategy in a preexisting RBBB cohort. We analyzed 237 patients with preexisting RBBB who underwent TAVI. The primary endpoint was the incidence of new PPI. Multivariate analyses investigating predictors for new PPI were performed. The overall PPI rate was 33.3%. Significant baseline predictors for new PPI were combination of RBBB, left anterior or posterior fascicular block, and first-degree atrioventricular block (odds ratio [OR] 2.55, 95% confidence interval [CI] 1.09 to 5.04), high calcium volume of noncoronary cusp (OR 2.08, 95% CI 1.05 to 4.10), and membranous septum (MS) length <2 mm (OR 2.02, 95% CI 1.09 to 3.75) in the univariate analysis and MS length <2 mm (OR 2.25, 95% CI 1.06 to 4.82) in the multivariate analysis. On the multivariate analysis including procedural variables, predilatation (OR 2.41, 95% CI 1.01 to 5.83), self-expanding valves (Corevalve, Evolut R, and Evolut Pro/Pro+; Medtronic Inc., Minneapolis, Minnesota) or mechanical expanding valves (Lotus/Lotus Edge; Boston Scientifics, Marlborough, Massachusetts) (OR 3.00, 95% CI 1.31 to 6.91), and implantation depth > MS length (OR 4.27, 95% CI 1.81 to 10.08) were significantly associated with new PPI. The incidence of new PPI increased according to the number of baseline predictors (0: 20.9%, 1: 34.3%, and ≥2: 52.0%) and procedural predictors (0: 3.7%, 1: 20.9%, 2: 40.5%, and 3: 60.0%). New PPI risk in a preexisting RBBB subset could be stratified by baseline factors. Device selection and implantation strategy considering MS length could prevent new PPI even in these high-risk population.


Aortic Valve Stenosis , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Bundle-Branch Block/epidemiology , Bundle-Branch Block/therapy , Pacemaker, Artificial/adverse effects , Aortic Valve Stenosis/complications , Risk Assessment , Risk Factors , Aortic Valve/surgery , Treatment Outcome , Heart Valve Prosthesis/adverse effects
10.
J Clin Med ; 12(23)2023 Nov 30.
Article En | MEDLINE | ID: mdl-38068484

BACKGROUND: Individuals with heart failure displaying supra-normal left ventricular ejection fraction (snLVEF) may exhibit less favorable clinical outcomes in contrast to their counterparts with normal left ventricular ejection fraction (nLVEF). The distinctive characteristics and mid-term prognosis of individuals with severe aortic stenosis and snLVEF following transcatheter aortic valve replacement (TAVR) remain enigmatic. METHODS: Among 7393 patients diagnosed with severe aortic stenosis who underwent TAVR between 2013 and 2019 and were enlisted in the optimized transcatheter valvular intervention (OCEAN-TAVI) multicenter registry (UMIN000020423), we selected patients with left ventricular ejection fraction (LVEF) ≥ 50%. snLVEF was defined as LVEF exceeding 65%. We compared the baseline characteristics and assessed three-year post-TAVR mortality and heart failure readmission rates between the snLVEF (LVEF > 65%) and nLVEF cohorts (LVER 50-65%). RESULTS: Our study cohort comprised 5989 patients (mean age 84.4 ± 5.1 years and 1783 males). Among these, 2819 patients were categorized within the snLVEF cohort, while the remaining 3170 were allocated to the nLVEF group. Individuals within the snLVEF cohort were more likely to be female and displayed lower levels of natriuretic peptides, as well as smaller left ventricular dimensions in comparison to their nLVEF counterparts (p < 0.05 for all). The presence of snLVEF emerged as an independent predictor of the three-year composite endpoint relative to nLVEF, with an adjusted hazard ratio of 1.16 (95% confidence interval 1.02-1.31, p = 0.023) after accounting for several potential confounding factors. CONCLUSIONS: snLVEF was relatively common among candidates for TAVR with preserved ejection fraction. Patients harboring snLVEF appear to manifest a distinctive clinical profile and encounter less favorable clinical outcomes following TAVR in contrast to those characterized by nLVEF.

11.
Contemp Clin Trials ; 134: 107358, 2023 Nov.
Article En | MEDLINE | ID: mdl-37852534

BACKGROUND: Despite the wide implementation of transcatheter aortic valve implantation (TAVI), the optimal antithrombotic therapy after TAVI has not been established yet. Owing to the accumulating evidence supporting the efficacy and safety of single antiplatelet therapy (SAPT) over dual antiplatelet therapy, the latest guideline recommends life-long SAPT. However, there is scarce evidence supporting SAPT compared with non-antithrombotic therapy. Given the vulnerability of patients undergoing TAVI in terms of high bleeding risk, the benefit of SAPT may be canceled out by its potential increased bleeding risk. STUDY DESIGN AND OBJECTIVES: Non-antithrombotic Therapy After Transcatheter Aortic Valve Implantation (NAPT) Trial is a prospective, randomized controlled, open-label blinded endpoint multicenter trial conducted in Japan, testing the non-inferiority of non-antithrombotic therapy compared with aspirin monotherapy in patients who underwent TAVI and had no indications for long-term oral anticoagulation therapy (OAC). Patients who successfully underwent trans-femoral TAVI for severe aortic stenosis with either balloon-expandable or self-expandable valves are eligible for inclusion. Key exclusion criteria are (i) occurrence of perioperative complications (ii) indications of taking antithrombotic drugs for other reasons; (iii) eGFR <30 ml/min/1.73 m2 or hemodialysis or peritoneal dialysis. A total of 360 patients will be randomized (1:1) to aspirin monotherapy vs. non-antithrombotic therapy. The primary outcome is a composite of all-cause mortality, myocardial infarction, stroke, and bleeding. All bleeding events based on the Valve Academic Research Consortium 3 are included as a component of the primary outcome. CONCLUSION: The NAPT trial will determine the non-inferiority of a non-antithrombotic therapy compared with aspirin monotherapy after TAVI.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Platelet Aggregation Inhibitors/adverse effects , Prospective Studies , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/drug therapy , Aortic Valve Stenosis/etiology , Aspirin/therapeutic use , Treatment Outcome
12.
Am J Cardiol ; 207: 140-149, 2023 11 15.
Article En | MEDLINE | ID: mdl-37738784

The optimal percent oversizing (%OS) using the SAPIEN3 Ultra (S3U) weighing the incidence of paravalvular regurgitation (PVR) ≥ mild against the risk of conduction disturbance (CD) is not known. This study sought to define an optimal extent of the annulus area %OS suitable for transcatheter aortic valve implantation with the S3U compared with the SAPIEN3 (S3). A total of 350 patients with the S3U were compared with 606 patients with the S3. Patients were categorized depending on the degree of %OS. PVR ≥ mild was observed in 8.9% of patients with the S3U and in 21.8% of those with the S3 (p <0.001). The S3U demonstrated a sustainably lower incidence of PVR ≥ mild than the S3 in any extent of %OS. There was an inverse proportional relation between the extent of %OS and frequency of PVR ≥ mild in the S3, whereas the S3U group provided little change. The incidences of PVR ≥ mild were steady >5%OS in the S3 (5% to 10%OS: 13.3%, and >10%OS: 12.1%) and >0%OS in the S3U (0% to 5%OS: 5.9%, 5% to 10%OS: 6.0%, and >10%OS: 6.1%). An increasing %OS was independently associated with the occurrence of CD (<0%OS: 9.8%, 0% to 5%OS: 13.1%, 5% to 10%OS: 16.6%, and >10%OS: 19.2%, p = 0.012). The incidence of PVR ≥ mild and/or CD was the lowest (10.1%) in the 0% to 5%OS in patients with the S3U. In conclusion, the HomoSAPIEN2 study suggests that the S3U tolerates a lesser degree of %OS for mitigating PVR ≥ mild than the S3. Minimal %OS, ranging from 0% to 5%, may be optimal for the S3U with balancing the risk of PVR and CD. Trial Identifier: UMIN000040413/URL: https://center6.umin.ac.jp/cgi-open-bin/ctr/ctr_view.cgi?recptno=R000046115.


Aortic Valve Insufficiency , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Hemodynamics , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Am J Cardiol ; 204: 130-139, 2023 10 01.
Article En | MEDLINE | ID: mdl-37541149

Electrocardiogram (ECG) left ventricular hypertrophy (LVH) is associated with the prognosis of patients with aortic stenosis. However, the impact of the presence or absence of ECG-LVH on the clinical outcomes after transcatheter aortic valve implantation (TAVI) is limited. This study aimed to assess the prognostic value of ECG-LVH among patients with aortic stenosis treated by TAVI. A total of 1,667 patients who underwent TAVI were prospectively enrolled into the OCEAN-TAVI (Optimized CathEter vAlvular iNtervention-Transcatheter Aortic Valve Implantation) registry. A total of 1,446 patients (mean age 84 years; 29.9% men) were analyzed. The Sokolow-Lyon index was used to determine the presence of ECG-LVH. LVH was also assessed using transthoracic echocardiography (TTE). We investigated the association between ECG-LVH and all-cause and cardiovascular mortality. This study identified ECG-LVH and TTE-LVH in 743 (51.5%) and 1,242 patients (86.0%), respectively. The Kaplan-Meier analysis revealed that all-cause mortality was significantly higher among patients without ECG-LVH than among those with ECG-LVH (log-rank p <0.001). In the multivariable analysis, the absence of ECG-LVH was independently associated with all-cause mortality (hazard ratio 1.98, 95% confidence interval 1.39 to 2.82, p <0.001), regardless of the presence or absence of TTE-LVH. Furthermore, the presence of TTE-LVH with the absence of ECG-LVH was observed in 575 patients (40%), which was associated with cardiovascular mortality (hazard ratio 2.84, 95% confidence interval 1.56 to 5.17, p <0.001). In conclusion, the absence of ECG-LVH was independently associated with an increased risk of all-cause mortality after TAVI. Risk stratification using both ECG-LVH and TTE-LVH is a useful predictor of adverse clinical outcomes after TAVI.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Female , Transcatheter Aortic Valve Replacement/adverse effects , Prognosis , Hypertrophy, Left Ventricular/diagnosis , Hypertrophy, Left Ventricular/epidemiology , Hypertrophy, Left Ventricular/etiology , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Registries , Aortic Valve/surgery , Treatment Outcome
14.
Struct Heart ; 7(3): 100153, 2023 May.
Article En | MEDLINE | ID: mdl-37273854

Background: Cardiac sympathetic nerve activity (SNA) is overactivated in heart failure patients and associated with clinical outcomes. The aim of this study is to investigate the early effect of MitraClip repair on cardiac SNA. Methods: We evaluated the change of cardiac SNA by 123I- meta-iodobenzylguanidine (MIBG) scintigraphy in patients who underwent MitraClip repair from March 2019 to June 2020 in our hospital. Patients without acute procedural success were excluded, including patients who died or underwent mitral valve surgery before discharge. MIBG scintigraphy was performed at baseline and 1 â€‹month after MitraClip repair. Results: We analyzed 48 patients (mean age 78.6 ± 10 years; 52.1% male; 37 secondary mitral regurgitation [SMR]/11 primary mitral regurgitation [PMR]). MR severity and New York Heart Association functional class significantly improved from baseline to 1 â€‹month after MitraClip repair (both p < 0.001). Overall, delay heart-mediastinum ratio (H/M) had no significant change, and washout rate (WR) showed a decreasing trend (delay H/M; pre 2.07 ± 0.46, post 2.05 ± 0.49, paired p = 0.348, WR; pre 36.1 ± 11.6%, post 33.6 ± 11.7%, paired p = 0.061). In PMR patients, WR was significantly decreased, however, delay H/M was not (delay H/M; pre 2.15 ± 0.50, post 2.10 ± 0.57, paired p = 0.019, WR; pre 34.6 ± 10.5%, post 26.7 ± 13.8%, paired p = 0.568). In contrast, in SMR patients, neither delay H/M nor WR were significantly changed (delay H/M; pre 2.05 ± 0.45, post 2.03 ± 0.47, paired p = 0.474, WR; pre 36.6 ± 11.9%, post 35.7 ± 10.4%, paired p = 0.523). Conclusions: Our study demonstrates that MitraClip repair could significantly decrease cardiac SNA of WR in PMR patients during 1-month follow-up, however, in SMR patients, the significant change of MIBG parameters was not observed.

15.
JACC Cardiovasc Interv ; 16(10): 1192-1204, 2023 05 22.
Article En | MEDLINE | ID: mdl-37225290

BACKGROUND: Data regarding the impact of high transcatheter heart valve (THV) implantation on coronary access after transcatheter aortic valve replacement (TAVR) as assessed by postimplantation computed tomography (CT) are scarce. OBJECTIVES: The authors sought to assess the impact of high THV implantation on coronary access after TAVR. METHODS: We included 160 and 258 patients treated with Evolut R/PRO/PRO+ and SAPIEN 3 THVs, respectively. In the Evolut R/PRO/PRO+ group, the target implantation depth was 1 to 3 mm using the cusp overlap view with commissural alignment technique for the high implantation technique (HIT), whereas it was 3 to 5 mm using 3-cusp coplanar view for the conventional implantation technique (CIT). In the SAPIEN 3 group, the HIT employed the radiolucent line-guided implantation, whereas the central balloon marker-guided implantation was used for the CIT. Post-TAVR CT was performed to analyze coronary accessibility. RESULTS: HIT reduced the incidence of new conduction disturbances after TAVR for both THVs. In the Evolut R/PRO/PRO+ group, post-TAVR CT showed that the HIT group had a higher incidence of the interference of THV skirt (22.0% vs 9.1%; P = 0.03) and a lower incidence of the interference of THV commissural posts (26.0% vs 42.7%; P = 0.04) with access to 1 or both coronary ostia compared with the CIT group. These incidences were similar between the HIT and CIT groups in the SAPIEN 3 group (THV skirt: 0.9% vs 0.7%; P = 1.00; THV commissural tabs: 15.7% vs 15.3%; P = 0.93). In both THVs, CT-identified risk of sinus sequestration in TAVR-in-TAVR was significantly higher in the HIT group compared with the CIT group (Evolut R/PRO/PRO+ group: 64.0% vs 41.8%; P = 0.009; SAPIEN 3 group: 17.6% vs 5.3%; P = 0.002). CONCLUSIONS: High THV implantation substantially reduced conduction disturbances after TAVR. However, post-TAVR CT revealed that there is a risk for unfavorable future coronary access after TAVR and sinus sequestration in TAVR-in-TAVR. (Impact of High Implantation of Transcatheter Heart Valve during Transcatheter Aortic Valve Replacement on Future Coronary Access; UMIN000048336).


Aortic Valve , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Tomography, X-Ray Computed
16.
Thromb J ; 21(1): 60, 2023 May 24.
Article En | MEDLINE | ID: mdl-37226249

BACKGROUND: Cancer-associated thrombosis is a frequent complication of cancer; however, little evidence is available regarding the association between cancer history and coronary artery stent thrombosis (ST). We aimed to investigate the relationship between cancer history and second-generation drug-eluting stent thrombosis (G2-ST). METHODS: From the REAL-ST (Retrospective Multicenter Registry of ST After First- and Second-Generation Drug-Eluting Stent Implantation) registry, this study evaluated 1265 patients (G2- ST cases, n = 253; controls, n = 1012) with cancer-related information available. RESULTS: The prevalence of patients with cancer history was higher (12.3% vs. 8.5%, p = 0.065), and that of currently diagnosed and currently treated cancer was significantly higher in ST cases than controls (3.6% vs. 1.4%, p = 0.021; 3.2% vs. 1.3%, p = 0.037, respectively). Multivariable logistic regression analysis revealed that cancer history was associated with late ST (odds ratio [OR]: 2.80, 95% confidence intervals [CI]: 0.92-8.55, p = 0.071) and very late ST (OR: 2.40, 95% CI: 1.02-5.65, p = 0.046), but not with early ST (OR: 1.01, 95% CI: 0.51-2.00, p = 0.97). During the median follow-up period of 872 days after the index ST events, patients with cancer history showed a higher mortality than those without, among both ST cases (hazard ratio [HR]: 1.93, 95% CI: 1.06-3.51, p = 0.031) and controls (HR: 1.93, 95% CI: 1.09-3.40, p = 0.023). CONCLUSION: A post hoc analysis of REAL-ST registry revealed that patients with G2-ST had a higher prevalence of currently diagnosed and currently treated cancer. Notably, cancer history was associated with the occurrence of late and very late ST, but not with early ST.

18.
Am J Cardiol ; 191: 14-22, 2023 03 15.
Article En | MEDLINE | ID: mdl-36623409

The impact of mild paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) remains controversial. We evaluated the impact of mild PVR after TAVI on long-term clinical outcomes. We included patients who underwent TAVI for severe symptomatic aortic stenosis between December 2008 and June 2019 at 2 international centers and compared all-cause death between the group with mild PVR (group 1) and the group with none or trace PVR (group 2). PVR was categorized using a 3-class grading scheme, and patients with PVR ≧ moderate and those who were lost to follow-up were excluded. This retrospective analysis included 1,404 patients (mean age 81.7 ± 6.5 years, 58.0% women). Three hundred fifty eight patients (25.5%) were classified into group 1 and 1,046 patients (74.5%) into group 2. At baseline, group 1 was older and had a lower body mass index, worse co-morbidities, and more severe aortic stenosis. To account for these differences, propensity score matching was performed, resulting in 332 matched pairs. Within these matched groups, during a mean follow-up of 3.2 years, group 1 had a significantly lower survival rate at 5 years (group 1: 62.0% vs group 2: 68.0%, log-rank p = 0.029, hazard ratio: 1.41 [95% confidence interval: 1.04 to 1.91]). In the matched cohort, patients with mild PVR had a significant 1.4-fold increased risk of mortality at 5 years after TAVI compared with those with none or trace PVR. Further studies with more patients are needed to evaluate the impact of longer-term outcomes.


Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/complications , Retrospective Studies , Aortic Valve Insufficiency/epidemiology , Aortic Valve Insufficiency/surgery , Aortic Valve Insufficiency/etiology , Treatment Outcome , Aortic Valve/surgery , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis Implantation/methods , Risk Factors
19.
JACC Cardiovasc Interv ; 16(1): 79-91, 2023 01 09.
Article En | MEDLINE | ID: mdl-36599591

BACKGROUND: Several trials demonstrated that aspirin monotherapy compared with aspirin plus clopidogrel is associated with a lower incidence of bleeding without an increased risk of ischemic events in patients after transcatheter aortic valve replacement (TAVR); however, there remains a paucity of data to prove the necessity of even aspirin monotherapy. OBJECTIVES: This study aimed to compare clinical outcomes and valve performance of the 3 different antithrombotic strategies post-TAVR from the OCEAN-TAVI (Optimized transCathEter vAlvular iNtervention) registry. METHODS: Patients who received anticoagulation or had procedural complications were excluded. The remaining patients were classified into 3 groups according to the antithrombotic regimen at discharge: 1) nonantithrombotic therapy (None); 2) single-antiplatelet therapy (SAPT); and 3) dual-antiplatelet therapy (DAPT). The primary outcome was the incidence of net adverse clinical events (NACEs) (ie, cardiovascular death, stroke, myocardial infarction, and life-threatening or major bleeding). RESULTS: Overall, 3,575 TAVR patients were included (None, 293; SAPT, 1,354; DAPT, 1,928). The median follow-up period was 841 days (IQR: 597-1,340 days). The incidence of NACEs did not differ between the groups (None vs SAPT: adjusted HR [aHR]: 1.18; P = 0.45; None vs DAPT: aHR: 1.09; P = 0.67). There was a lower incidence of all bleeding in patients with no antithrombotics (None vs SAPT: aHR: 0.63; P = 0.12; None vs DAPT: aHR: 0.51; P = 0.04). The valve performance was similar among the groups. Leaflet thrombosis was detected in 8.5% of the nonantithrombotic group. CONCLUSIONS: Compared with SAPT/DAPT, the nonantithrombotic strategy was not associated with an increased risk of NACEs and potentially reduced the risk of bleeding events. The nonantithrombotic strategy may be an acceptable alternative to SAPT/DAPT in selected patients with TAVR.


Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Platelet Aggregation Inhibitors/adverse effects , Treatment Outcome , Drug Therapy, Combination , Aspirin/adverse effects , Hemorrhage/chemically induced , Registries , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery
...