1.
JMIR Med Inform ; 12: e51171, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38596848

ABSTRACT

Background: With the capability to render prediagnoses, consumer wearables have the potential to affect subsequent diagnoses and the level of care in the health care delivery setting. Despite this, postmarket surveillance of consumer wearables has been hindered by the lack of codified terms in electronic health records (EHRs) to capture wearable use. Objective: We sought to develop a weak supervision-based approach to demonstrate the feasibility and efficacy of EHR-based postmarket surveillance on consumer wearables that render atrial fibrillation (AF) prediagnoses. Methods: We applied data programming, where labeling heuristics are expressed as code-based labeling functions, to detect incidents of AF prediagnoses. A labeler model was then derived from the predictions of the labeling functions using the Snorkel framework. The labeler model was applied to clinical notes to probabilistically label them, and the labeled notes were then used as a training set to fine-tune a classifier called Clinical-Longformer. The resulting classifier identified patients with an AF prediagnosis. A retrospective cohort study was conducted, where the baseline characteristics and subsequent care patterns of patients identified by the classifier were compared against those who did not receive a prediagnosis. Results: The labeler model derived from the labeling functions showed high accuracy (0.92; F1-score=0.77) on the training set. The classifier trained on the probabilistically labeled notes accurately identified patients with an AF prediagnosis (0.95; F1-score=0.83). The cohort study conducted using the constructed system carried enough statistical power to verify the key findings of the Apple Heart Study, which enrolled a much larger number of participants, where patients who received a prediagnosis tended to be older, male, and White with higher CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes, stroke, vascular disease, age 65-74 years, sex category) scores (P<.001). We also made a novel discovery that patients with a prediagnosis were more likely to use anticoagulants (525/1037, 50.63% vs 5936/16,560, 35.85%) and have an eventual AF diagnosis (305/1037, 29.41% vs 262/16,560, 1.58%). At the index diagnosis, the existence of a prediagnosis did not distinguish patients based on clinical characteristics, but did correlate with anticoagulant prescription (P=.004 for apixaban and P=.01 for rivaroxaban). Conclusions: Our work establishes the feasibility and efficacy of an EHR-based surveillance system for consumer wearables that render AF prediagnoses. Further work is necessary to generalize these findings for patient populations at other sites.

2.
Commun Med (Lond) ; 3(1): 167, 2023 Dec 13.
Article in English | MEDLINE | ID: mdl-38092993

ABSTRACT

BACKGROUND: Arrhythmia symptoms are frequent complaints in children and often require a pediatric cardiology evaluation. Data regarding the clinical utility of wearable technologies are limited in children. We hypothesize that an Apple Watch can capture arrhythmias in children. METHODS: We present an analysis of patients ≤18 years-of-age who had signs of an arrhythmia documented by an Apple Watch. We include patients evaluated at our center over a 4-year-period and highlight those receiving a formal arrhythmia diagnosis. We evaluate the role of the Apple Watch in arrhythmia diagnosis, the results of other ambulatory cardiac monitoring studies, and findings of any EP studies. RESULTS: We identify 145 electronic-medical-record identifications of Apple Watch, and find arrhythmias confirmed in 41 patients (28%) [mean age 13.8 ± 3.2 years]. The arrythmias include: 36 SVT (88%), 3 VT (7%), 1 heart block (2.5%) and wide 1 complex tachycardia (2.5%). We show that invasive EP study confirmed diagnosis in 34 of the 36 patients (94%) with SVT (2 non-inducible). We find that the Apple Watch helped prompt a workup resulting in a new arrhythmia diagnosis for 29 patients (71%). We note traditional ambulatory cardiac monitors were worn by 35 patients (85%), which did not detect arrhythmias in 10 patients (29%). In 73 patients who used an Apple Watch for recreational or self-directed heart rate monitoring, 18 (25%) sought care due to device findings without any arrhythmias identified. CONCLUSION: We demonstrate that the Apple Watch can record arrhythmia events in children, including events not identified on traditionally used ambulatory monitors.


Wearable devices, such as smart watches, have become popular for the monitoring of health, particularly for people with heart conditions. Wearable devices have been well-studied in adults, however there is less information available on their effectiveness in monitoring children's health. We reviewed the heart electrical recordings of a group of children who submitted recordings obtained from their Apple Watches during moments when they felt as though their heart's rhythm was abnormal. The Apple Watches captured rhythm abnormalities that matched the diagnoses obtained using heart monitors used clinically. This study shows that use of Apple Watches can enable clinicians to identify abnormalities that many traditional at-home monitoring devices do not detect. Thus, wearable devices, such as the Apple Watch, could be used to help identify heart rhythm disorders in children.

4.
Circ Arrhythm Electrophysiol ; 15(2): e010557, 2022 02.
Article in English | MEDLINE | ID: mdl-35089800

ABSTRACT

BACKGROUND: Limited data exist regarding implantable cardioverter defibrillator (ICD) usage in infants and toddlers. This study evaluates ICD placement indications, procedural techniques, programming strategies, and outcomes of ICDs in infants and toddlers. METHODS: This is a single-center retrospective review of all patients ≤3 years old who received an ICD from 2009 to 2021. RESULTS: Fifteen patients received an ICD at an age of 1.2 years (interquartile range [IQR], 0.1-2.4; 12 [80%] women; weight, 8.2 kg [IQR, 4.2-12.6]) and were followed for a median of 4.28 years (IQR, 1.40-5.53) or 64.2 patient-years. ICDs were placed for secondary prevention in 12 patients (80%). Diagnoses included 8 long-QT syndromes (53%), 4 idiopathic ventricular tachycardias/ventricular fibrillations (VFs; 27%), 1 recurrent ventricular tachycardia with cardiomyopathy (7%), 1 VF with left ventricular noncompaction (7%), and 1 catecholaminergic polymorphic ventricular tachycardia (7%). All implants were epicardial, with a coil in the pericardial space. Intraoperative defibrillation safety testing was attempted in 11 patients (73%), with VF induced in 8 (53%). Successful restoration of sinus rhythm was achieved in all tested patients with a median of 9 (IQR, 7.3-11.3) J or 0.90 (IQR, 0.68-1.04) J/kg. Complications consisted of 1 postoperative chylothorax and 3 episodes of feeding intolerance. VF detection was programmed to 250 (IQR, 240-250) ms with first shock delivering 10 (IQR, 5-15) J or 1.1 (IQR, 0.8-1.4) J/kg. Three patients (20%) received appropriate shocks for ventricular tachycardia/VF. No patient received an inappropriate shock. There were 2 (13%) ventricular lead fractures (at 2.6 and 4.2 years post-implant), 1 (7%) pocket-site infection, and 2 (13%) generator exchanges. All patients were alive, and 1 patient (7%) received a heart transplant. CONCLUSIONS: ICDs can be safely and effectively placed for sudden death prevention in infants and toddlers with good midterm outcomes.


Subject(s)
Arrhythmias, Cardiac/therapy , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable , Electric Countershock/instrumentation , Age Factors , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Child, Preschool , Death, Sudden, Cardiac/etiology , Electric Countershock/adverse effects , Female , Humans , Infant , Male , Primary Prevention , Prosthesis Design , Recovery of Function , Retrospective Studies , Secondary Prevention , Time Factors , Treatment Outcome
5.
Intensive Care Med Exp ; 9(1): 54, 2021 Oct 18.
Article in English | MEDLINE | ID: mdl-34657982

ABSTRACT

BACKGROUND: The COVID-19 pandemic has caused a global mechanical ventilator shortage for treatment of severe acute respiratory failure. Development of novel breathing devices has been proposed as a low cost, rapid solution when full-featured ventilators are unavailable. Here we report the design, bench testing and preclinical results for an 'Automated Bag Breathing Unit' (ABBU). Output parameters were validated with mechanical test lungs followed by animal model testing. RESULTS: The ABBU design uses a programmable motor-driven wheel assembled for adult resuscitation bag-valve compression. ABBU can control tidal volume (200-800 ml), respiratory rate (10-40 bpm), inspiratory time (0.5-1.5 s), assist pressure sensing (- 1 to - 20 cm H2O), manual PEEP valve (0-20 cm H2O). All set values are displayed on an LCD screen. Bench testing with lung simulators (Michigan 1600, SmartLung 2000) yielded consistent tidal volume delivery at compliances of 20, 40 and 70 (mL/cm H2O). The delivered fraction of inspired oxygen (FiO2) decreased with increasing minute ventilation (VE), from 98 to 47% when VE was increased from 4 to 16 L/min using a fixed oxygen flow source of 5 L/min. ABBU was tested in Berkshire pigs (n = 6, weight of 50.8 ± 2.6 kg) utilizing normal lung model and saline lavage induced lung injury. Arterial blood gases were measured following changes in tidal volume (200-800 ml), respiratory rate (10-40 bpm), and PEEP (5-20 cm H2O) at baseline and after lung lavage. Physiological levels of PaCO2 (≤ 40 mm Hg [5.3 kPa]) were achieved in all animals at baseline and following lavage injury. PaO2 increased in lavage injured lungs in response to incremental PEEP (5-20 cm H2O) (p < 0.01). At fixed low oxygen flow rates (5 L/min), delivered FiO2 decreased with increased VE. CONCLUSIONS: ABBU provides oxygenation and ventilation across a range of parameter settings that may potentially provide a low-cost solution to ventilator shortages. A clinical trial is necessary to establish safety and efficacy in adult patients with diverse etiologies of respiratory failure.

9.
Sci Transl Med ; 9(406)2017 Sep 06.
Article in English | MEDLINE | ID: mdl-28878011

ABSTRACT

Conventional methods for histopathologic tissue diagnosis are labor- and time-intensive and can delay decision-making during diagnostic and therapeutic procedures. We report the development of an automated and biocompatible handheld mass spectrometry device for rapid and nondestructive diagnosis of human cancer tissues. The device, named MasSpec Pen, enables controlled and automated delivery of a discrete water droplet to a tissue surface for efficient extraction of biomolecules. We used the MasSpec Pen for ex vivo molecular analysis of 20 human cancer thin tissue sections and 253 human patient tissue samples including normal and cancerous tissues from breast, lung, thyroid, and ovary. The mass spectra obtained presented rich molecular profiles characterized by a variety of potential cancer biomarkers identified as metabolites, lipids, and proteins. Statistical classifiers built from the histologically validated molecular database allowed cancer prediction with high sensitivity (96.4%), specificity (96.2%), and overall accuracy (96.3%), as well as prediction of benign and malignant thyroid tumors and different histologic subtypes of lung cancer. Notably, our classifier allowed accurate diagnosis of cancer in marginal tumor regions presenting mixed histologic composition. Last, we demonstrate that the MasSpec Pen is suited for in vivo cancer diagnosis during surgery performed in tumor-bearing mouse models, without causing any observable tissue harm or stress to the animal. Our results provide evidence that the MasSpec Pen could potentially be used as a clinical and intraoperative technology for ex vivo and in vivo cancer diagnosis.


Subject(s)
Mass Spectrometry/instrumentation , Neoplasms/diagnosis , Organ Specificity , Animals , Disease Models, Animal , Female , Humans , Intraoperative Care , Mice, Nude , Molecular Diagnostic Techniques , Neoplasms/surgery , Principal Component Analysis
10.
J Biomed Opt ; 20(11): 115002, 2015 Nov.
Article in English | MEDLINE | ID: mdl-26538329

ABSTRACT

The ability to distinguish macrophage subtypes noninvasively could have diagnostic potential in cancer, atherosclerosis, and diabetes, where polarized M1 and M2 macrophages play critical and often opposing roles. Current methods to distinguish macrophage subtypes rely on tissue biopsy. Optical imaging techniques based on light scattering are of interest as they can be translated into biopsy-free strategies. Because mitochondria are relatively strong subcellular light scattering centers, and M2 macrophages are known to have enhanced mitochondrial biogenesis compared to M1, we hypothesized that M1 and M2 macrophages may have different angular light scattering profiles. To test this, we developed an in vitro angle-resolved forward light scattering measurement system. We found that M1 and M2 macrophage monolayers scatter relatively unequal amounts of light in the forward direction between 1.6 deg and 3.2 deg with M2 forward scattering significantly more light than M1 at increasing angles. The ratio of forward scattering can be used to identify the polarization state of macrophage populations in culture.


Subject(s)
Macrophages/cytology , Macrophages/physiology , Microscopy, Phase-Contrast/instrumentation , Nephelometry and Turbidimetry/instrumentation , Refractometry/instrumentation , Animals , Cells, Cultured , Equipment Design , Equipment Failure Analysis , Light , Macrophages/classification , Male , Mice , Mice, Inbred C57BL , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity