Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 13 de 13
Filter
1.
Vasa ; 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39017671

ABSTRACT

Background: Bifemoral arterial access is common in patients undergoing transcatheter aortic valve implantation (TAVI), with a primary treatment access (TAVI access) and a secondary non-TAVI access. Pseudoaneurysm (PSA) is an important complication of femoral arterial puncture. Major vascular complications after TAVI are well described, but little is known about PSA. Patients and methods: A total of 2063 patients underwent transfemoral TAVI between January 2014 and January 2020. Vascular ultrasound of the common femoral artery was assessed before and after TAVI. We compared patient characteristics, periprocedural risk scores, procedural characteristics, and access site bleeding events according to Valve Academic Research Consortium 3 (VARC-3) criteria, length of stay (LOS), and all-cause mortality at one year between patients with (46) and without (2017) PSA. Results: The incidence of PSA after TAVI was 2.2% (46/2063). All PSA were successfully treated with ultrasound-guided manual compression (UGMC) or thrombin injection (UGTI) without complications. Patients with PSA had lower platelet counts (210×1000/µl vs. 234×1000/µl; p<0.05), more heart failure symptoms on admission (91% vs. 25%; p<0.05), were more often treated with (N)OACs for atrial fibrillation (AF; 54% vs. 38%; p <0.05), and were less often treated with aspirin (35% vs. 51%; p<0.03). Multivariate analysis identified secondary access site (odds ratio [OR] 8.11; p<0.001) and (N)OAC therapy (OR 1.31; p = 0.037) as risk factors for PSA development. PSA is associated with VARC-3 type 1-3 access site bleeding and longer LOS (15.2 ± 11.3 d vs. 11.6 ± 8.9 d; p<0.01), but this did not affect one year mortality (17% vs. 14%; p = 0.53). Conclusions: Pseudoaneurysms are an important complication after TAVI and are associated with access site bleeding and prolonged hospital stay. (N)OAC therapy and secondary access are important risk factors. Pseudoaneurysms can be safely and effectively treated with thrombin injection and do not affect one-year mortality.

2.
Echocardiography ; 41(8): e15888, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39042643

ABSTRACT

BACKGROUND: Device-related thrombosis (DRT) is a common finding after left atrial appendage closure (LAAC) and is associated with worse outcomes. As women are underrepresented in clinical studies, further understanding of sex differences in DRT patients is warranted. METHODS AND RESULTS: This sub-analysis from the EUROC-DRT-registry compromises 176 patients with diagnosis of DRT after LAAC. Women, who accounted for 34.7% (61/176) of patients, were older (78.0 ± 6.7 vs. 74.9 ± 9.1 years, p = .06) with lower rates of comorbidities. While DRT was detected significantly later in women (173 ± 267 vs. 127 ± 192 days, p = .01), anticoagulation therapy was escalated similarly, mainly with initiation of novel oral anticoagulant (NOAC), vitamin K antagonist (VKA) or heparin. DRT resolution was achieved in 67.5% (27/40) of women and in 75.0% (54/72) of men (p = .40). In the remaining cases, an intensification/switch of anticoagulation was conducted in 50.% (9/18) of men and in 41.7% (5/12) of women. Final resolution was achieved in 72.5% (29/40) cases in women, and in 81.9% (59/72) cases in men (p = .24). Women were followed-up for a similar time as men (779 ± 520 vs. 908 ± 687 days, p = .51). Kaplan-Meier analysis revealed no difference in mortality rates in women (Hazard Ratio [HR]: 1.73, 95%-Confidence interval [95%-CI]: .68-4.37, p = .25) and no differences in stroke (HR: .83, 95%-CI: .30-2.32, p = .72) within 2 years after LAAC. CONCLUSION: Evaluation of risk factors and outcome revealed no differences between men and women, with DRT in women being diagnosed significantly later. Women should be monitored closely to assess for DRT formation/resolution. Treatment strategies appear to be equally effective.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Registries , Thrombosis , Humans , Female , Male , Atrial Appendage/surgery , Aged , Thrombosis/etiology , Atrial Fibrillation/surgery , Sex Factors , Anticoagulants/therapeutic use , Risk Factors , Postoperative Complications , Septal Occluder Device , Treatment Outcome , Echocardiography, Transesophageal/methods , Europe/epidemiology , Left Atrial Appendage Closure
3.
J Am Heart Assoc ; 13(15): e034086, 2024 Aug 06.
Article in English | MEDLINE | ID: mdl-39041603

ABSTRACT

BACKGROUND: Detailed visualization and precise measurements of aortic valve dimensions are critical for the success of transcatheter aortic valve implantation and for the prevention of complications. Currently, multislice computed tomography is the gold standard for assessment of the aortic annulus and surrounding structures to determine the prosthesis size. New technologies such as virtual reality (VR) not only enable 3-dimensional (3D) visualization with the potential to improve understanding of anatomy and pathology but also allow measurements in 3D. This study aims to investigate the feasibility, accuracy, and reproducibility of VR for the visualization of the aortic valve, the surrounding structures, and its role in preprocedural sizing for transcatheter aortic valve implantation. METHODS AND RESULTS: Based on the preprocedural multislice computed tomography data, 3mensio measurements and 3D visualizations and measurements using VR software were performed retrospectively on 60 consecutive patients who underwent transcatheter aortic valve implantation at our heart center. There were no significant differences but strong correlations between the VR measurements compared with those performed with the 3mensio software. Furthermore, excellent or good intra- and interobserver reliability could be demonstrated for all values. In a structured questionnaire, users reported that VR simplified anatomical understanding, improved 3D comprehension of adjacent structures, and was associated with very good self-perceived depth perception. CONCLUSIONS: The use of VR for preprocedural transcatheter aortic valve implantation sizing is feasible and has precise and reproducible measurements. In addition, 3D visualization improves anatomical understanding and orientation. To evaluate the potential benefits of 3D visualization for planning further cardiovascular interventions, research in this field is needed.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Feasibility Studies , Heart Valve Prosthesis , Imaging, Three-Dimensional , Multidetector Computed Tomography , Transcatheter Aortic Valve Replacement , Virtual Reality , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Reproducibility of Results , Male , Female , Transcatheter Aortic Valve Replacement/methods , Transcatheter Aortic Valve Replacement/instrumentation , Aged, 80 and over , Aged , Retrospective Studies , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Prosthesis Design , Observer Variation , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted
4.
Circulation ; 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38836358

ABSTRACT

BACKGROUND: Whether aortic valve stenosis (AS) can adversely affect systemic endothelial function independently of standard modifiable cardiovascular risk factors is unknown. METHODS: We therefore investigated endothelial and cardiac function in an experimental model of AS mice devoid of standard modifiable cardiovascular risk factors and human cohorts with AS scheduled for transcatheter aortic valve replacement. Endothelial function was determined by flow-mediated dilation using ultrasound. Extracellular hemoglobin (eHb) concentrations and NO consumption were determined in blood plasma of mice and humans by ELISA and chemiluminescence. This was complemented by measurements of aortic blood flow using 4-dimensional flow acquisition by magnetic resonance imaging and computational fluid dynamics simulations. The effects of plasma and red blood cell (RBC) suspensions on vascular function were determined in transfer experiments in a murine vasorelaxation bioassay system. RESULTS: In mice, the induction of AS caused systemic endothelial dysfunction. In the presence of normal systolic left ventricular function and mild hypertrophy, the increase in the transvalvular gradient was associated with elevated eryptosis, increased eHb and plasma NO consumption; eHb sequestration by haptoglobin restored endothelial function. Because the aortic valve orifice area in patients with AS decreased, postvalvular mechanical stress in the central ascending aorta increased. This was associated with elevated eHb, circulating RBC-derived microvesicles, eryptotic cells, lower haptoglobin levels without clinically relevant anemia, and consecutive endothelial dysfunction. Transfer experiments demonstrated that reduction of eHb by treatment with haptoglobin or elimination of fluid dynamic stress by transcatheter aortic valve replacement restored endothelial function. In patients with AS and subclinical RBC fragmentation, the remaining circulating RBCs before and after transcatheter aortic valve replacement exhibited intact membrane function, deformability, and resistance to osmotic and hypoxic stress. CONCLUSIONS: AS increases postvalvular swirling blood flow in the central ascending aorta, triggering RBC fragmentation with the accumulation of hemoglobin in the plasma. This increases NO consumption in blood, thereby limiting vascular NO bioavailability. Thus, AS itself promotes systemic endothelial dysfunction independent of other established risk factors. Transcatheter aortic valve replacement is capable of limiting NO scavenging and rescuing endothelial function by realigning postvalvular blood flow to near physiological patterns. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05603520. URL: https://www.clinicaltrials.gov; Unique identifier: NCT01805739.

5.
JACC Cardiovasc Imaging ; 17(8): 847-860, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38795109

ABSTRACT

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.


Subject(s)
Aortic Valve Stenosis , Aortic Valve , Calcinosis , Echocardiography, Stress , Multidetector Computed Tomography , Predictive Value of Tests , Severity of Illness Index , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Female , Male , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve/pathology , Calcinosis/diagnostic imaging , Calcinosis/physiopathology , Aged, 80 and over , Reproducibility of Results , ROC Curve , Ventricular Function, Left , Area Under Curve , Stroke Volume , Hemodynamics
6.
Front Cardiovasc Med ; 11: 1328906, 2024.
Article in English | MEDLINE | ID: mdl-38596690

ABSTRACT

Background: Understanding complex cardiac anatomy is essential for percutaneous left atrial appendage (LAA) closure. Conventional multi-slice computed tomography (MSCT) and transesophageal echocardiography (TEE) are now supported by advanced 3D printing and virtual reality (VR) techniques for three-dimensional visualization of volumetric data sets. This study aimed to investigate their added value for LAA closure procedures. Methods: Ten patients scheduled for interventional LAA closure were evaluated with MSCT and TEE. Patient-specific 3D printings and VR models were fabricated based on MSCT data. Ten cardiologists then comparatively assessed LAA anatomy and its procedure relevant surrounding structures with all four imaging modalities and rated their procedural utility on a 5-point Likert scale questionnaire (from 1 = strongly agree to 5 = strongly disagree). Results: Device sizing was rated highest in MSCT (MSCT: 1.9 ± 0.8; TEE: 2.6 ± 0.9; 3D printing: 2.5 ± 1.0; VR: 2.5 ± 1.1; p < 0.01); TEE, VR, and 3D printing were superior in the visualization of the Fossa ovalis compared to MSCT (MSCT: 3.3 ± 1.4; TEE: 2.2 ± 1.3; 3D printing: 2.2 ± 1.4; VR: 1.9 ± 1.3; all p < 0.01). The major strength of VR and 3D printing techniques was a superior depth perception (VR: 1.6 ± 0.5; 3D printing: 1.8 ± 0.4; TEE: 2.9 ± 0.7; MSCT: 2.6 ± 0.8; p < 0.01). The visualization of extracardiac structures was rated less accurate in TEE than MSCT (TEE: 2.6 ± 0.9; MSCT: 1.9 ± 0.8, p < 0.01). However, 3D printing and VR insufficiently visualized extracardiac structures in the present study. Conclusion: A true 3D visualization in VR or 3D printing provides an additional value in the evaluation of the LAA for the planning of percutaneous closure. In particular, the superior perception of depth was seen as a strength of a 3D visualization. This may contribute to a better overall understanding of the anatomy. Clinical studies are needed to evaluate whether a more comprehensive understanding through advanced multimodal imaging of patient-specific anatomy using VR may translate into improved procedural outcomes.

7.
J Cardiovasc Dev Dis ; 11(3)2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38535105

ABSTRACT

Due to the complex and variable anatomy of the left atrial appendage, percutaneous left atrial appendage closure (LAAC) can be challenging. In this study, we investigated the impact of fusion imaging (FI) on the LAAC learning curve of two interventionalists. The first interventionalist (IC 1) was initially trained without FI and continued his training with FI. The second interventionalist (IC 2) performed all procedures with FI. We compared the first 36 procedures without FI of IC 1 (group 1) with his next 36 interventions with FI (group 2). Furthermore, group 1 was compared to 36 procedures of IC 2 who directly started his training with FI (group 3). Group 1 demonstrated that the learning curve without FI has a flat course with weak correlations for fluoroscopy time, contrast volume, and procedure time, but not for dose area product. Group 2 with FI showed improvement with a steep course and strong correlations for all four parameters. In group 3, we also saw a steep progression with strong correlations. Furthermore, the mean measurements of the parameters in the groups with FI decreased significantly as an indicator of procedural efficacy. We demonstrated that FI may improve the learning curve of experienced and non-experienced ICs.

8.
Interv Cardiol ; 19: e01, 2024.
Article in English | MEDLINE | ID: mdl-38464494

ABSTRACT

Optimised implantation depth (OID) is crucial to obtain the best haemodynamic and clinical outcome during transcatheter heart valve (THV) deployment. OID ensures a better haemodynamic profile and is associated with a potential reduction in permanent pacemaker implantations, both of which are important during transcatheter aortic valve replacement (TAVR). Apart from patient-related anatomic conditions, many factors, such as THV and wire selection, as well as implantation strategies, can be controlled by the operator and facilitate the implantation process. However, there are only limited data dealing with predictors for OID. Therefore, the aim of this review was to outline factors and tools that might influence the final implantation depth during TAVR procedures, potentially influencing the outcome.

9.
J Invasive Cardiol ; 36(1)2024 Jan.
Article in English | MEDLINE | ID: mdl-38224296

ABSTRACT

OBJECTIVES: Dynamic Coronary Roadmap (DCR) is a software tool that creates a real-time dynamic coronary artery overlay on fluoroscopic images. The efficacy of DCR in significantly reducing contrast medium use during percutaneous coronary interventions (PCI) has previously been shown. In this study, we aimed to determine if DCR is equally effective irrespective of the performing investigator's experience level. METHODS: In this sub-analysis of a monocentric, open-label, randomized trial, 130 patients with hemodynamic relevant coronary type A and B lesions were randomized and contrast medium use was conducted with (+) or without (-) DCR software. PCI was randomly allocated and performed by an investigator with high (A) or medium (B) experience level. RESULTS: Overall, contrast medium use was significantly reduced by both investigators in the +DCR group, and Investigator B used significantly less contrast medium with the software than Investigator A. The DCR software was not accompanied by increased radiation exposure for the patients or the teams. On the contrary, dose area product was reduced by both investigators, but was significantly reduced by the highly experienced investigator when using DCR. Fluoroscopy time was not different between investigators. Procedural success was 100%. Serious in-hospital adverse events were not observed. One of Investigator A's patients suffered from post-procedural acute kidney injury in the -DCR group. CONCLUSIONS: DCR significantly reduces contrast medium use during PCI irrespective of investigator's experience level.


Subject(s)
Acute Kidney Injury , Percutaneous Coronary Intervention , Humans , Percutaneous Coronary Intervention/adverse effects , Diagnostic Imaging , Coronary Vessels , Heart , Contrast Media/adverse effects
10.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Article in English | MEDLINE | ID: mdl-38276659

ABSTRACT

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

11.
Int J Cardiol ; 399: 131690, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38160912

ABSTRACT

BACKGROUND: Impella™ is increasingly used in cardiogenic shock. However, thromboembolic and bleeding events are frequent during percutaneous mechanical circulatory support (pMCS). OBJECTIVE: Therefore, we aimed to explore the optimal anticoagulation regime for pMCS to prevent thromboembolism and bleedings. METHODS: This hypothesis-generating multi-center cohort study investigated 170 patients with left-Impella™ support. We (A) compared bleeding/thrombotic events in two centers with therapeutic range (TR-aPTT) activated partial thromboplastin time (60-80s) and (B) compared events of these centers with one center with intermediate range aPTT (40-60s). RESULTS: After matching, there were no differences in patients' characteristics. In centers aiming at TR-aPTT, major bleeding was numerically lower with aPTT <60s within 48 h of left-Impella™ support, versus patients that achieved the aimed aPTT of ≥60s [aPTT ≥60s: 22 (37.3%) vs. aPTT<60s 14 (23.7%); Hazard ratio [HR], 0.62 (95%) CI, 0.28-1.38; p = 0.234]. Major cardiovascular and cerebrovascular adverse events (MACCE) did not differ between groups. In comparison of centers, TR-aPTT strategy showed higher major bleeding rates [TR: 8 (47.1%) vs. intermediate range: 1 (5.9%); HR, 0.06 (95%) CI, 0.01-0.45; p = 0.006]. MACCE were lower in the intermediate range aPTT group as well [TR 12 (70.6%) vs. intermediate range 5 (29.4%) HR, 0.32 (95%) CI, 0.11-0.92; p = 0.034]. CONCLUSION: This pilot analysis showed that lowering UFH-targets in left-Impella™ supported CS patients seems to be a safe and promising strategy for reducing major bleedings without increasing MACCE. This needs to be validated in larger, randomized clinical trials.


Subject(s)
Heparin , Thromboembolism , Humans , Anticoagulants , Shock, Cardiogenic/diagnosis , Cohort Studies , Partial Thromboplastin Time , Hemorrhage/chemically induced , Hemorrhage/diagnosis , Thromboembolism/chemically induced , Retrospective Studies
12.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Article in English | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

ABSTRACT

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Subject(s)
Pacemaker, Artificial
13.
JACC cardiovasc. interv ; 12(5): 433-443, Mar. 2019. tabela, gráfico
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024526

ABSTRACT

Abstract OBJECTIVES: The aim of this study was to compare transcatheter aortic valve replacement (TAVR) with the Acurate neo (NEO) and Evolut PRO (PRO) devices. BACKGROUND: The NEO and PRO bioprostheses are 2 next-generation self-expanding devices developed for TAVR. METHODS: The NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) registry retrospectively included patients who underwent transfemoral TAVR with either NEO or PRO valves at 24 centers between January 2012 and March 2018. One-to-one propensity score matching resulted in 251 pairs. Pre-discharge and 30-day Valve Academic Research Consortium (VARC)-2 defined outcomes were evaluated. Binary logistic regression was performed to adjust the treatment effect for propensity score quintiles. RESULTS: A total of 1,551 patients (n = 1,263 NEO; n = 288 PRO) were included. The mean age was 82 years, and the mean Society of Thoracic Surgeons score was 5.1%. After propensity score matching (n = 502), VARC-2 device success (90.6% vs. 91.6%; p = 0.751) and pre-discharge moderate to severe (II+) paravalvular aortic regurgitation (7.3% vs. 5.7%; p = 0.584) were comparable between the NEO and PRO groups. Furthermore, there were no significant differences in any 30-day clinical outcome between matched NEO and PRO pairs, including all-cause mortality (3.2% vs. 1.2%; p = 0.221), stroke (2.4% vs. 2.8%; p = 1.000), new permanent pacemaker implantation (11.0% vs. 12.8%; p = 0.565), and VARC-2 early safety endpoint (10.6% vs. 10.4%; p = 1.000). Logistic regression on the unmatched cohort confirmed a similar risk of VARC-2 device success, paravalvular aortic regurgitation II+, and 30-day clinical outcomes after NEO and PRO implantation. CONCLUSIONS: (AU)


Subject(s)
Humans , Transcatheter Aortic Valve Replacement
SELECTION OF CITATIONS
SEARCH DETAIL