Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.999
Filter
1.
EJNMMI Res ; 14(1): 63, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38976101

ABSTRACT

BACKGROUND: Positron emission tomography (PET) is now an established diagnostic method for myocardial perfusion imaging (MPI) in coronary artery disease, which is the main cause of death globally. The available tracers show several limitations, therefore, the 18F-labelled tracer is in high demand nowadays. The preclinical studies on normal Wistar rats aimed to characterise two potential, novel radiotracers, [18F]SYN1 and [18F]SYN2, to evaluate which is a better candidate for PET MPI cardiotracer. RESULTS: The dynamic microPET images showed rapid myocardial uptake for both tracers. However, the uptake was higher and also stable for [18F]SYN2, with an average standardized uptake value of 3.8. The biodistribution studies confirmed that [18F]SYN2 uptake in the cardiac muscle was high and stable (3.02%ID/g at 15 min and 2.79%ID/g at 6 h) compared to [18F]SYN1 (1.84%ID/g at 15 min and 0.32%ID/g at 6 h). The critical organs determined in dosimetry studies were the small intestine and the kidneys. The estimated effective dose for humans was 0.00714 mSv/MBq for [18F]SYN1 and 0.0109 mSv/MBq for [18F]SYN2. The tested dose level of 2 mg/kg was considered to be the No Observed Adverse Effect Level (NOAEL) for both candidates. The better results were achieved for [18F]SYN2, therefore, further preclinical studies were conducted only for this tracer. Radioligand binding assays showed significant responses in 3 from 68 assays: muscarinic acetylcholine M1 and M2 receptors and potassium channel hERG. The compound was mostly metabolised via an oxidative N-dealkylation, while the fluor substituent was not separated from the molecule. CONCLUSION: [18F]SYN2 showed a favourable pharmacodynamic and pharmacokinetic profile, which enabled a clear visualization of the heart in microPET. The compound was well-tolerated in studies in normal rats with moderate radiation exposure. The results encourage further exploration of [18F]SYN2 in clinical studies.

2.
Int J Radiat Biol ; : 1-11, 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38953870

ABSTRACT

PURPOSE: Radiation-induced alterations in gene expression show great promise for dose reconstruction and for severity prediction of acute health effects. Among several genes explored as potential biomarkers, FDXR is widely used due to high upregulation in white blood cells following radiation exposure. Nonetheless, the absence of a standardized protocols for gene expression-based biodosimetry is a notable gap that warrants attention to enhance the accuracy, reproducibility and reliability. The objective of this study was to evaluate the sensitivity of transcriptional biodosimetry to differences in protocols used by different laboratories and establish guidelines for the calculation of calibration curve using FDXR expression data. MATERIAL AND METHODS: Two sets of irradiated blood samples generated during RENEB exercise were used. The first included samples irradiated with known doses including: 0, 0.25, 0.5, 1, 2, 3 and 4 Gy. The second set consisted of three 'blind' samples irradiated with 1.8 Gy, 0.4 Gy and a sham-irradiated sample. After irradiation, samples were incubated at 37 °C over 24 h and sent to participating laboratories, where RNA isolation and FDXR expression analysis by qPCR were performed using sets of primers/probes and reference genes specific for each laboratory. Calibration curves based on FDXR expression data were generated using non-linear and linear regression and used for dose estimation of 'blind' samples. RESULTS: Dose estimates for sham-irradiated sample (0.020-0.024 Gy) and sample irradiated with 0.4 Gy (0.369-0.381 Gy) showed remarkable consistency across all laboratories, closely approximating the true doses regardless variation in primers/probes and reference genes used. For sample irradiated with 1.8 Gy the dose estimates were less precise (1.198-2.011 Gy) but remained within an acceptable margin for triage within the context of high dose range. CONCLUSION: Methodological differences in reference genes and primers/probes used for FDXR expression measurement do not have a significant impact on the dose estimates generated, provided that all reference genes performed as expected and the primers/probes target a similar set of transcript variants. The preferred method for constructing a calibration curve based on FDXR expression data involves employing linear regression to establish a function that describes the relationship between the logarithm of absorbed dose and FDXR ΔCt values. However, one should be careful with using non-irradiated sample data as these cannot be accurately represented on a logarithmic scale. A standard curve generated using this approach can give reliable dose estimations in a dose range from 50 mGy to 4 Gy at least.

3.
J Appl Clin Med Phys ; : e14451, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38952057

ABSTRACT

PURPOSE: This study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems. METHODS AND MATERIALS: We assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film. RESULTS: We observed that the 1 × 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 × 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of ∼1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies. CONCLUSIONS: This study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.

4.
J Nucl Med ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38960712

ABSTRACT

Novel theranostic approaches using radiopharmaceuticals targeting prostate-specific membrane antigen (PSMA) have emerged for treating metastatic castration-resistant prostate cancer. The physical properties and commercial availability of 177Lu make it one of the most used radionuclides for radiopharmaceutical therapy (RPT). In this literature review, we aimed at comparing the dosimetry of the most used [177Lu]Lu-PSMA RPT compounds. Methods: This was a systematic review and metaanalysis of [177Lu]Lu-PSMA RPT (617, I&T, and J591) dosimetry in patients with prostate cancer. Absorbed doses in Gy/GBq for each organ at risk (kidney, parotid and submandibular glands, bone marrow, liver, and lacrimal glands) and for tumor lesions (bone and nonbone lesions) were extracted from included articles. These were used to estimate the pooled average absorbed dose of each agent in Gy/GBq and in Gy/cycle, normalized to the injected activity (per cycle) used in the VISION (7.4 GBq), SPLASH (6.8 GBq), and PROSTACT trials (5.8 GBq). Results: Twenty-nine published articles comprising 535 patients were included in the metaanalysis. The pooled doses (weighted average across studies) of [177Lu]Lu-PSMA-617 and [177Lu]Lu-PSMA-I&T were 4.04 Gy/GBq (17 studies, 297 patients) and 4.70 Gy/GBq (10 studies, 153 patients) for the kidney (P = 0.10), 5.85 Gy/GBq (14 studies, 216 patients) and 2.62 Gy/GBq (5 studies, 86 patients) for the parotids (P < 0.01), 5.15 Gy/GBq (5 studies, 81 patients) and 4.35 Gy/GBq (1 study, 18 patients) for the submandibular glands (P = 0.56), 11.03 Gy/GBq (6 studies, 121 patients) and 19.23 Gy/GBq (3 studies, 53 patients) for the lacrimal glands (P = 0.20), 0.24 Gy/GBq (12 studies, 183 patients) and 0.19 Gy/GBq (4 studies, 68 patients) for the bone marrow (P = 0.31), and 1.11 Gy/GBq (9 studies, 154 patients) and 0.56 Gy/GBq (4 studies, 56 patients) for the liver (P = 0.05), respectively. Average tumor doses tended to be higher for [177Lu]Lu-PSMA-617 than for [177Lu]Lu-PSMA-I&T in soft tissue tumor lesions (4.19 vs. 2.94 Gy/GBq; P = 0.26). Dosimetry data of [177Lu]Lu-J591 were limited to one published study of 35 patients with reported absorbed doses of 1.41, 0.32, and 2.10 Gy/GBq to the kidney, bone marrow, and liver, respectively. Conclusion: In this metaanalysis, there was no significant difference in absorbed dose between [177Lu]Lu-PSMA-I&T and [177Lu]Lu-PSMA-617. There was a possible trend toward a higher kidney dose with [177Lu]Lu-PSMA-I&T and a higher tumor lesion dose with [177Lu]Lu-PSMA-617. It remains unknown whether this finding has any clinical impact. The dosimetry methodologies were strikingly heterogeneous among studies, emphasizing the need for standardization.

5.
J Nucl Med ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38960710

ABSTRACT

Functional liver parenchyma can be damaged from treatment of liver malignancies with 90Y selective internal radiation therapy (SIRT). Evaluating functional parenchymal changes and developing an absorbed dose (AD)-toxicity model can assist the clinical management of patients receiving SIRT. We aimed to determine whether there is a correlation between 90Y PET AD voxel maps and spatial changes in the nontumoral liver (NTL) function derived from dynamic gadoxetic acid-enhanced MRI before and after SIRT. Methods: Dynamic gadoxetic acid-enhanced MRI scans were acquired before and after treatment for 11 patients undergoing 90Y SIRT. Gadoxetic acid uptake rate (k1) maps that directly quantify spatial liver parenchymal function were generated from MRI data. Voxel-based AD maps, derived from the 90Y PET/CT scans, were binned according to AD. Pre- and post-SIRT k1 maps were coregistered to the AD map. Absolute and percentage k1 loss in each bin was calculated as a measure of loss of liver function, and Spearman correlation coefficients between k1 loss and AD were evaluated for each patient. Average k1 loss over the patients was fit to a 3-parameter logistic function based on AD. Patients were further stratified into subgroups based on lesion type, baseline albumin-bilirubin scores and alanine transaminase levels, dose-volume effect, and number of SIRT treatments. Results: Significant positive correlations (ρ = 0.53-0.99, P < 0.001) between both absolute and percentage k1 loss and AD were observed in most patients (8/11). The average k1 loss over 9 patients also exhibited a significant strong correlation with AD (ρ ≥ 0.92, P < 0.001). The average percentage k1 loss of patients across AD bins was 28%, with a logistic function model demonstrating about a 25% k1 loss at about 100 Gy. Analysis between patient subgroups demonstrated that k1 loss was greater among patients with hepatocellular carcinoma, higher alanine transaminase levels, larger fractional volumes of NTL receiving an AD of 70 Gy or more, and sequential SIRT treatments. Conclusion: Novel application of multimodality imaging demonstrated a correlation between 90Y SIRT AD and spatial functional liver parenchymal degradation, indicating that a higher AD is associated with a larger loss of local hepatocyte function. With the developed response models, PET-derived AD maps can potentially be used prospectively to identify localized damage in liver and to enhance treatment strategies.

6.
J Nucl Med ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38960715

ABSTRACT

Image-based dosimetry-guided radiopharmaceutical therapy has the potential to personalize treatment by limiting toxicity to organs at risk and maximizing the therapeutic effect. The 177Lu dosimetry challenge of the Society of Nuclear Medicine and Molecular Imaging consisted of 5 tasks assessing the variability in the dosimetry workflow. The fifth task investigated the variability associated with the last step, dose conversion, of the dosimetry workflow on which this study is based. Methods: Reference variability was assessed by 2 medical physicists using different software, methods, and all possible combinations of input segmentation formats and time points as provided in the challenge. General descriptive statistics for absorbed dose values from the global submissions from participants were calculated, and variability was measured using the quartile coefficient of dispersion. Results: For the liver, which included lesions with high uptake, variabilities of up to 36% were found. The baseline analysis showed a variability of 29% in absorbed dose results for the liver from datasets where lesions included and excluded were grouped, indicating that variation in how lesions in normal liver were treated was a significant source of variability. For other organs and lesions, variability was within 7%, independently of software used except for the local deposition method. Conclusion: The choice of dosimetry method or software had a small contribution to the overall variability of dose estimates.

7.
Med Phys ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38980220

ABSTRACT

An Addendum to the AAPM's TG-51 protocol for the determination of absorbed dose to water is presented for electron beams with energies between 4 MeV and 22 MeV ( 1.70 cm ≤ R 50 ≤ 8.70 cm $1.70\nobreakspace {\rm cm} \le R_{\text{50}} \le 8.70\nobreakspace {\rm cm}$ ). This updated formalism allows simplified calibration procedures, including the use of calibrated cylindrical ionization chambers in all electron beams without the use of a gradient correction. New k Q $k_{Q}$ data are provided for electron beams based on Monte Carlo simulations. Implementation guidance is provided. Components of the uncertainty budget in determining absorbed dose to water at the reference depth are discussed. Specifications for a reference-class chamber in electron beams include chamber stability, settling, ion recombination behavior, and polarity dependence. Progress in electron beam reference dosimetry is reviewed. Although this report introduces some major changes (e.g., gradient corrections are implicitly included in the electron beam quality conversion factors), they serve to simplify the calibration procedure. Results for absorbed dose per linac monitor unit are expected to be up to approximately 2 % higher using this Addendum compared to using the original TG-51 protocol.

8.
Phys Med ; 124: 103420, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38970950

ABSTRACT

PURPOSE: The purpose of this study is to investigate the dosimetric characteristics of a collimator for minibeam radiotherapy (MBRT) with film dosimetry and Monte Carlo (MC) simulations. The outcome of MBRT with respect to conventional RT using a glioma preclinical model was also evaluated. METHODS: A multi-slit collimator was designed to be used with commercial small animal irradiator. The collimator was built by aligning 0.6 mm wide and 5 mm thick parallel lead leaves at 0.4 mm intervals. Dosimetry characteristics were evaluated by Gafchromic (CG) films and TOPAS Monte Carlo (MC) code. An in vivo experiment was performed using a glioma preclinical model by injecting two million GL261cells subcutaneously and treating with 25 Gy, single fraction, with MBRT and conventional RT. Survival curves and acute radiation damage were measured to compare both treatments. RESULTS: A satisfactory agreement between experimental results and MC simulations were obtained, the measured FWHM and distance between the peaks were respectively 0.431 and 1.098 mm. In vivo results show that MBRT can provide local tumor control for three weeks after RT treatment and a similar survival fraction of open beam radiotherapy. No severe acute effects were seen for the MBRT group. CONCLUSIONS: We developed a minibeam collimator and presented its dosimetric features. Satisfactory agreement between MC and GC films was found with differences consistent with uncertainties due to fabrication and set-up errors. The survival curves of MBRT and open field RT are similar while atoxicity is dramatically lower with MBRT, preliminarily confirming the expected effect.

9.
Phys Med Biol ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38959910

ABSTRACT

OBJECTIVE: To develop and benchmark a novel 3D dose verification technique consisting of polymer-gel-dosimeter (PGD) with cone-beam-CT (CBCT) readout through a two-institution study. The technique has potential for wide and robust applicability through reliance on CBCT readout. Approach: Three treatment plans (3-Field, TG119-C-shape spine, 4-target SRS) were created by two independent institutions (Institution A and B). A Varian Truebeam LINAC was used to deliver the plans to NIPAM polymer gel dosimeters produced at both institutions using an identical approach. For readout, a slow CBCT scan mode was used to acquire pre- and post-irradiation images of the gel (1 mm slice thickness). Independent gel analysis tools were used to process the PGD images (A: VistaAce software, B: in-house MATLAB code). Comparing planned and measured doses, the analysis involved a combination of 1D line profiles, 2D contour plots, and 3D global gamma maps (criteria ranging between 2%1mm and 5%2mm, with a 10% dose threshold). Main Results: For all gamma criteria tested, the 3D gamma pass rates were all above 90% for 3-field and 88% for the SRS plan. For the C-shape spine plan, we benchmarked our 2% 2mm result against previously published work using film analysis (93.4%). For 2%2mm, 99.4% (Institution A data), and 89.7% (Institution B data) were obtained based on VistaAce software analysis, 83.7% (Institution A data), and 82.9% (Institution B data) based on MATLAB. Significance: The benchmark data demonstrate that when two institutions follow the same rigorous procedures gamma passing rates up to 99%, for 2%2mm criteria can be achieved for substantively different treatment plans. The use of different software and calibration techniques may have contributed to the variation in the 3D gamma results. By sharing the data across institutions, we observe the gamma passing rate is more consistent within each pipeline, indicating the need for standardized analysis methods.

10.
Brachytherapy ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38964977

ABSTRACT

PURPOSE: High dose-rate (HDR) brachytherapy is integral for the treatment of numerous cancers. Preclinical studies involving HDR brachytherapy are limited. We aimed to describe a novel platform allowing multi-modality studies with clinical HDR brachytherapy and external beam irradiators, establish baseline dosimetry standard of a preclinical orthovoltage irradiator, to determine accurate dosimetric methods. METHODS: A dosimetric assessment of a commercial preclinical irradiator was performed establishing the baseline dosimetry goals for clinical irradiators. A 3D printed platform was then constructed with 14 brachytherapy channels at 1cm spacing to accommodate a standard tissue culture plate at a source-to-cell distance (SCD) of 1 cm or 0.4 cm. 4-Gy CT-based treatment plans were created in clinical treatment planning software and delivered to 96-well tissue culture plates using an Ir192 source or a clinical linear accelerator. Standard calculation models for HDR brachytherapy and external beam were compared to corresponding deterministic model-based dose calculation algorithms (MBDCAs). Agreement between predicted and measured dose was assessed with 2D-gamma passing rates to determine the best planning methodology. RESULTS: Mean (±standard deviation) and median dose measured across the plate for the preclinical irradiator was 423.7 ± 8.5 cGy and 430.0 cGy. Mean percentage differences between standard and MBDCA dose calculations were 9.4% (HDR, 1 cm SCD), 0.43% (HDR, 0.4 cm SCD), and 2.4% (EBRT). Predicted and measured dose agreement was highest for MBDCAs for all modalities. CONCLUSION: A 3D-printed tissue culture platform can be used for multi-modality irradiation studies with great accuracy. This tool will facilitate preclinical studies to reveal biologic differences between clinically relevant radiation modalities.

11.
Article in English | LILACS-Express | LILACS | ID: biblio-1535344

ABSTRACT

Purpose: To describe the acoustic characteristics of a classroom, voice quality, fatigue, and vocal load of university professors. Methods: Exploratory, observational, longitudinal, and descriptive study with a single group of participants, including vocal monitoring data over two weeks. Acoustic characterization of the classroom, perceptual-auditory evaluation, and acoustic analysis of voice samples were conducted before and after classes. Vocal dosimetry was performed during classes, and the Vocal Fatigue Index (VFI) was assessed at the beginning of each week. Descriptive analysis of the findings was conducted, and randomization test was performed to verify the internal reliability of the judge. Results: All participants reported speaking loudly in the classroom, with the majority reporting vocal changes in the past six months, and only one participant reported a current vocal change. The classroom had acoustical measures and estimations that deviated from established standards. The professors used high vocal intensities during classes. After the classes, an increase in the absolute values of the aggregated data for CAPE-V, jitter, and fundamental frequency was found, varying within the range of normality. Furthermore, there was an observed increase in both post-lesson intensity and VFI when comparing the two-week period. Conclusions: Vocal intensities and VFI were possibly impacted by the acoustics of the classroom. The increase in average VFI between the weeks may be attributed to a cumulative fatigue sensation. Further research with a larger number of participants and in acoustically conditioned classrooms is suggested in order to evaluate collective intervention proposals aimed at reducing the vocal load on teachers.


Objetivo: Describir las características acústicas, calidad vocal, fatiga y carga vocal de profesores universitarios. Métodos: Estudio exploratorio, observacional, longitudinal, descriptivo con un solo grupo de participantes y datos de monitoreo vocal durante dos semanas. Se realizó caracterización acústica de la sala, evaluación auditiva-perceptiva y acústica de muestras de voz antes y después de las clases. Se realizó dosimetría vocal durante las clases y se verificó el Índice de Fatiga Vocal (IFV) en dos semanas. Se realizó un análisis descriptivo de los hallazgos y una prueba de aleatorización para verificar la confiabilidad interna del juez. Resultados: Todos los participantes informaron hablar en voz alta en clase, la mayoría informó cambios vocales en los últimos seis meses y solo uno informó cambios vocales actuales. La sala presentó mediciones y estimaciones acústicas fuera de las normas establecidas. Los profesores utilizaron intensidades vocales altas durante las clases. Hubo un aumento en los valores absolutos de los datos agrupados para CAPE-V, jitter y frecuencia fundamental, variando dentro de los límites normales, después de las clases. La intensidad después de las clases y el IFV, en la comparación entre las dos semanas, mostraron un aumento. Conclusiones: La dosis vocal y el IFV posiblemente se vieron afectados por la acústica del aula. El aumento del IFV medio entre semanas pudo deberse a la sensación de cansancio acumulada. Se sugieren nuevas investigaciones con un mayor número de participantes y que se realicen en la sala acondicionada acústicamente para evaluar propuestas de intervención colectiva, con el objetivo de reducir la carga vocal de los docentes.

12.
Phys Med ; 123: 103403, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38870643

ABSTRACT

PURPOSE: Although plastic scintillator detectors (PSDs) are considered ideal dosimeters for small field dosimetry in conventional linear accelerators (linacs), the impact of the magnetic field strength on the response of the PSD must be investigated. METHODS: A linac Monte Carlo (MC) head model for a low-field MR-linac was validated for small field dosimetry and utilized to calculate field output factors (OFs). The MC-calculated OFs were compared with the treatment planning system (TPS)-calculated OFs and measured OFs using a Blue Physics (BP) Model 10 commercial PSD and a synthetic diamond detector. The field-specific correction factors, [Formula: see text] , were calculated for the PSD in the presence of a 0.35 T and magnetic field. The impact of the source focal spot size and initial electron energy on the MC-calculated OFs was investigated. RESULTS: Good agreement to within 2 % was found between the MC-calculated OFs and BP PSD OFs except for the 0.415 × 0.415 cm2 field size. The BP PSD [Formula: see text] correction factors were calculated to be within 1 % of unity. For field sizes ≥1.66 × 1.66 cm2, the MC-calculated OFs were relatively insensitive to the focal spot size and initial electron energy to within 2.5 %. However, for smaller field sizes, the MC-calculated OFs were found to differ up to 9.50 % and 7.00 % when the focal spot size and initial electron energy was varied, respectively. CONCLUSIONS: The BP PSD was deemed suitable for small field dosimetry in MR-linacs without requiring any [Formula: see text] correction factors.

13.
Phys Med ; 123: 103405, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38870645

ABSTRACT

The effect of mammography measurement conditions was investigated to evaluate their impact on measurement uncertainties in clinical practice. The most prominent physical X-ray beam quantities i.e., - air kerma, half-value layer, and X-ray tube voltage - were examined by measuring the response of two ionization chambers and six X-ray multimeters (XMMs) of different models. Measurements were performed using several anode/filter combinations and both with and without the compression paddle in the X-ray beam. Maximum differences of higher than 6 % were found for all quantities when the dosimeter displayed value was compared with the reference value or the variation within the clinical anode/filter combinations Mo/Mo and Mo/Rh were considered. The study showed that the calibration procedure with the W/Al anode/filter combination was reliable only for ionization chambers, and the response of XMMs varies in such a way that the calibration coefficient cannot be predicted between various measurement conditions used in calibration and clinical practices. XMM calibrations are typically performed without a compression paddle in the beam, and the response of the XMM changes when radiation quality is slightly altered. If XMM specific data is not available, based on this study, an additional uncertainty of 2 % (k = 1) could be used as a typical estimate, at least for air kerma measurements. XMMs should be used for clinical measurements in mammography only with correct settings. If the correct settings are not available, the XMMs should not be used or used only with extreme caution.

14.
Int J Radiat Biol ; : 1-9, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38889539

ABSTRACT

INTRODUCTION: Medulloblastoma is a central nerves tumor that often occurs in pediatrics. The main radiotherapy technique for this tumor type is craniospinal irradiation (CSI), through which the whole brain and spinal cord are exposed to radiation. Due to the immaturity of healthy organs in pediatrics, radiogenic side effects such as second cancer are more severe. Accordingly, the current study aimed to evaluate the risk of secondary cancer development in healthy organs following CSI. MATERIALS AND METHODS: Seven organs at risk (OARs) including skin, eye lens, thyroid, lung, liver, stomach, bladder, colon, and gonads were considered and the dose received by each OAR during CSI was measured inside an anthropomorphic RANDO phantom by TLDs. Then, the mean obtained dose for each organ was used to estimate the probability of secondary malignancy development according to the recommended cancer risk coefficients for specific organs. RESULTS: The results demonstrated that the stomach and colon are at high risk of secondary malignancy occurrence, while the skin has the lowest probability of secondary cancer development. The total received dose after the treatment course by all considered organs was lower than the corresponding tolerable dose levels. CONCLUSIONS: From the results, it can be concluded that some OARs during CSI are highly at risk of secondary cancer development. This issue may be of concern due to organ immaturity in pediatrics which can intensify the radiogenic effects of radiation exposure. Accordingly, strict shielding the OARs during craniospinal radiotherapy and/or sparing them from the radiation field through modern techniques such as hadron therapy is highly recommended.

15.
Front Oncol ; 14: 1307516, 2024.
Article in English | MEDLINE | ID: mdl-38884089

ABSTRACT

Introduction: Glioblastoma (grade IV) is the most aggressive primary brain tumor in adults, representing one of the biggest therapeutic challenges due to its highly aggressive nature. In this study, we investigated the impact of millimeter waves on tridimensional glioblastoma organoids derived directly from patient tumors. Our goal was to explore novel therapeutic possibilities in the fight against this challenging disease. Methods: The exposure setup was meticulously developed in-house, and we employed a comprehensive dosimetry approach, combining numerical and experimental methods. Biological endpoints included a global transcriptional profiling analysis to highlight possible deregulated pathways, analysis of cell morphological changes, and cell phenotypic characterization which are all important players in the control of glioblastoma progression. Results and discussion: Our results revealed a significant effect of continuous millimeter waves at 30.5 GHz on cell proliferation and apoptosis, although without affecting the differentiation status of glioblastoma cells composing the organoids. Excitingly, when applying a power level of 0.1 W (Root Mean Square), we discovered a remarkable (statistically significant) therapeutic effect when combined with the chemotherapeutic agent Temozolomide, leading to increased glioblastoma cell death. These findings present a promising interventional window for treating glioblastoma cells, harnessing the potential therapeutic benefits of 30.5 GHz CW exposure. Temperature increase during treatments was carefully monitored and simulated with a good agreement, demonstrating a negligible involvement of the temperature elevation for the observed effects. By exploring this innovative approach, we pave the way for improved future treatments of glioblastoma that has remained exceptionally challenging until now.

16.
Phys Med ; 123: 103406, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38875931

ABSTRACT

PURPOSE: Ionisation chamber based reference dosimetry in magnetic resonance linear accelerators (MRL) aimed for radiotherapy requires correction for recombination losses. Published studies have found that such corrections can be carried out using the two-voltage method. These studies have, however, not included comparison with recombination corrections based on the Niatel method, which can be seen as a robust reference method due to its clear separation of initial and volume recombination and its explicit account of the pulsed nature of the dose delivery. The primary objective of this work therefore was to carry out such a comparison. MATERIALS AND METHODS: Four Farmer-type chambers (PTW-30006 and PTW-30013) were placed in a water phantom in 1.5 T Elekta Unity MRL. The chambers were oriented antiparallel or perpendicular to the static magnetic field B0 and irradiated at a source-to-surface distance of 133.5 cm with a 10 × 10 cm2 field size. RESULTS: The two-voltage method gave results in agreement (within 0.1%) with the recombination corrections derived from the Niatel method. The recombination corrections from three Niatel parameter sets (one based on a Varian Truebeam and two obtained directly in the MRL) deviated less than 0.1% from each other. A systematic shift in the recombination correction of less than 0.05% was observed if polarity corrections were not applied. CONCLUSIONS: The study supports the use of the two-voltage method in MRLs based on its excellent agreement with the Niatel method. This work, therefore, complements existing knowledge as previous studies have not included a comparison with the Niatel method.

17.
Radiologie (Heidelb) ; 2024 Jun 14.
Article in German | MEDLINE | ID: mdl-38877140

ABSTRACT

CLINICAL-METHODOLOGICAL PROBLEM: Imaging procedures employing ionizing radiation require compliance with European directives and national regulations in order to protect patients. Each exposure must be indicated, individually adapted, and documented. Unacceptable dose exceedances must be detected and reported. These tasks are time-consuming and require meticulous diligence. STANDARD RADIOLOGICAL METHODS: Computed tomography (CT) is the most important contributor to medical radiation exposure. Optimizing the patient's dose is therefore mandatory. Use of modern technology and reconstruction algorithms already reduces exposure. Checking the indication, planning, and performing the examination are further important process steps with regard to radiation protection. Patient exposure is usually monitored by dose management systems (DMS). In special cases, a risk assessment is required by calculating the organ doses. METHODOLOGICAL INNOVATIONS: Artificial intelligence (AI)-assisted techniques are increasingly used in various steps of the process: they support examination planning, improve patient positioning, and enable automated scan length adjustments. They also provide real-time estimates of individual organ doses. EVALUATION: The integration of AI into medical imaging is proving successful in terms of dose optimization in various areas of the radiological workflow, from reconstruction to examination planning and performing exams. However, the use of AI in conjunction with DMS has not yet been considered on a large scale. PRACTICAL RECOMMENDATION: AI processes offer promising tools to support dose management. However, their implementation in the clinical setting requires further research, extensive validation, and continuous monitoring.

18.
J Nucl Med ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38936975

ABSTRACT

Internal dosimetry supports safe and effective patient management during radionuclide therapy. Yet, it is associated with high clinical workload, costs, and patient burden, as patient scans at multiple time points (MTPs) must be acquired. Dosimetry based on imaging at a single time point (STP) has continuously gained popularity. However, MTP protocols, used as a reference to judge the validity of STP dosimetry, differ depending on local requirements and deviate from the unknown patient-specific ground truth pharmacokinetics. The aim of this study was to compare the error and optimum time point for different STP approaches using different reference MTP protocols. Methods: Whole-body SPECT/CT scans of 7 patients (7.4-8.9 GBq of [177Lu]Lu-PSMA-I&T) were scheduled at 24, 48, 72, and 168 h after injection. Sixty lesions, 14 kidneys, and 10 submandibular glands were delineated in the SPECT/CT data. Two curve models, that is, a mono- and a biexponential model, were fitted to the MTP data, in accordance with goodness-of-fit analysis (coefficients of variation, sum of squared errors). Three population-based STP approaches were compared: one method published by Hänscheid et al., one by Jackson et al., and one using population-based effective half-lives in the mono- or biexponential curve models. Percentage differences between STP and MTP dosimetry were evaluated. Results: Goodness-of-fit parameters show that a monoexponential function and a biexponential function with shared population-based parameters and physical tail are reasonable reference models. When comparing both reference models, we observed maximum differences of -44%, -19%, and -28% in the estimated absorbed doses for lesions, kidneys, and salivary glands, respectively. STP dosimetry with an average deviation of less than 10% from MTP dosimetry may be feasible; however, this deviation and the optimum imaging time point showed a dependence on the chosen reference protocol. Conclusion: STP dosimetry for [177Lu]Lu-PSMA therapy is promising to boost the integration of dosimetry into clinical routine. According to our patient cohort, 48 h after injection may be regarded as a compromise for STP dosimetry for lesions and at-risk organs. The results from this analysis show that a common gold standard for dosimetry is desirable to allow for reliable and comparable STP dosimetry.

19.
Phys Med Biol ; 69(14)2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38830362

ABSTRACT

Dosimetry of ultra-high dose rate beams is one of the critical components which is required for safe implementation of FLASH radiotherapy (RT) into clinical practice. In the past years several national and international programmes have emerged with the aim to address some of the needs that are required for translation of this modality to clinics. These involve the establishment of dosimetry standards as well as the validation of protocols and dosimetry procedures. This review provides an overview of recent developments in the field of dosimetry for FLASH RT, with particular focus on primary and secondary standard instruments, and provides a brief outlook on the future work which is required to enable clinical implementation of FLASH RT.


Subject(s)
Radiometry , Radiotherapy Dosage , Radiometry/methods , Humans , Radiotherapy/methods , Radiation Dosage
20.
Cancers (Basel) ; 16(11)2024 May 31.
Article in English | MEDLINE | ID: mdl-38893216

ABSTRACT

Objectives: We investigated spatial patterns between primary and recurrent tumor sites and assessed long-term toxicity after dose escalation stereotactic body radiation therapy (SBRT) to the dominant intra-prostatic nodule (DIN). Materials and methods: In 33 patients with intermediate-high-risk prostate cancer (PCa), doses up to 50 Gy were administered to the DIN. Recurrence sites were determined and compared to the original tumor development sites through multiparametric MRI and 68Ga-labeled prostate-specific membrane antigen (PSMA) positron emission tomography/computed tomography (68Ga-PSMA-PET/CT) images. Overlap rates, categorized as 75% or higher for full overlap, and 25-74% for partial overlap, were assessed. Long-term toxicity is reported. Results: All patients completed treatment, with only one receiving concomitant androgen deprivation therapy (ADT). Recurrences were diagnosed after a median of 33 months (range: 17-76 months), affecting 13 out of 33 patients (39.4%). Intra-prostatic recurrences occurred in 7 patients (21%), with ≥75% overlap in two, a partial overlap in another two, and no overlap in the remaining three patients. Notably, five patients with intra-prostatic recurrences had synchronous bone and/or lymph node metastases, while six patients had isolated bone or lymph node metastasis without intra-prostatic recurrences. Extended follow-up revealed late grade ≥ 2 GU and GI toxicity in 18% (n = 6) and 6% (n = 2) of the patients. Conclusions: Among patients with intermediate-high-risk PCa undergoing focal dose-escalated SBRT without ADT, DIN recurrences were infrequent. When present, these recurrences were typically located at the original site or adjacent to the initial tumor. Conversely, relapses beyond the DIN and in extra-prostatic (metastatic) sites were prevalent, underscoring the significance of systemic ADT in managing this patient population. Advances in knowledge: Focal dose-escalated prostate SBRT prevented recurrences in the dominant nodule; however, extra-prostatic recurrence sites were frequent.

SELECTION OF CITATIONS
SEARCH DETAIL
...