Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.527
Filter
1.
Front Nucl Med ; 4: 1426650, 2024.
Article in English | MEDLINE | ID: mdl-39355210

ABSTRACT

Introduction: Nuclear medicine infection imaging is routinely performed with the use of leukocytes radiolabelled with technetium-99m hexamethylpropyleneamine oxime ([99mTc]Tc-HMPAO) and single-photon emission computed tomography (SPECT). Positron emission tomography (PET) is more sensitive than SPECT and results in higher-quality images. Zirconium-89 (89Zr) is a positron emitter with a half-life of 78.4 h, which translates to the biological half-life and slow biodistribution of intact cells and allows delayed PET imaging for more accurate biodistribution of the labelled leukocytes to infection foci. A first-in-human study with [89Zr]Zr-oxine-leukocytes in four healthy volunteers was reported in 2022. Our first-in-human study utilising the cell surface labelling approach aimed to image infection in patients with the use of 89Zr-labelled leukocytes, using p-isothiocyanatobenzyl-desferrioxamine B (Df-Bz-NCS) as a bifunctional chelating agent, and to compare the scan quality and biodistribution of [89Zr]Zr-Df-Bz-NCS-labelled leukocytes on PET images to SPECT images obtained with [99mTc]Tc-HMPAO-labelled leukocytes. Methods: Leukocytes were isolated from whole-blood samples of eight patients with clinically and/or radiologically confirmed infection. Isolated leukocytes were labelled with [99mTc]Tc-HMPAO according to standardised methods, and [89Zr]Zr-Df-Bz-NCS according to our previously published radiolabelling method. Whole-body SPECT imaging was performed 2 and 18 h post injection of [99mTc]Tc-HMPAO-labelled leukocytes, and whole-body PET/CT was performed 3 and 24 h post injection of [89Zr]Zr-Df-Bz-NCS-labelled leukocytes in seven patients. Results: Successful [89Zr]Zr-Df-Bz-NCS-leukocyte labelling was achieved. High labelling efficiencies were obtained (81.7% ± 3.6%; n = 8). A mean high viability of [89Zr]Zr-Df-Bz-NCS-labelled leukocytes was observed (88.98% ± 12.51%). The [89Zr]Zr-Df-Bz-NCS-leukocyte labelling efficiency was not significantly affected by the white blood cell count of the patient. The performance of [99mTc]Tc-HMPAO- and [89Zr]Zr-Df-Bz-NCS-labelled leukocytes, in terms of the ability to accurately detect infection, were similar in two out of seven patients, and [99mTc]Tc-HMPAO-labelled leukocytes outperformed [89Zr]Zr-Df-Bz-NCS-labelled leukocytes in one patient with femoral osteomyelitis. However, in two cases of pulmonary pathology, [89Zr]Zr-Df-Bz-NCS-labelled leukocytes demonstrated improved pathological uptake. No skeletal activity was observed in any of the patients imaged with [89Zr]Zr-Df-Bz-NCS-labelled leukocytes, illustrating the in vivo stability of the radiolabel. Discussion: Although the [89Zr]Zr-Df-Bz-NCS-leukocyte labelling aspect of this study was noteworthy, infection imaging did not yield convincingly positive results due to the pulmonary trapping of intravenously administered [89Zr]Zr-Df-Bz-NCS-labelled leukocytes.

2.
Front Nucl Med ; 4: 1355912, 2024.
Article in English | MEDLINE | ID: mdl-39355215

ABSTRACT

Radiopharmaceutical therapy has been widely adopted owing primarily to the development of novel radiopharmaceuticals. To fully utilize the potential of these RPTs in the era of precision medicine, therapy must be optimized to the patient's tumor characteristics. The vastly disparate dosimetry methodologies need to be harmonized as the first step towards this. Multiple factors play a crucial role in the shift from empirical activity administration to patient-specific dosimetry-based administrations from RPT. Factors such as variable responses seen in patients with presumably similar clinical characteristics underscore the need to standardize and validate dosimetry calculations. These efforts combined with ongoing initiatives to streamline the dosimetry process facilitate the implementation of radiomolecular precision oncology. However, various challenges hinder the widespread adoption of personalized dosimetry-based activity administration, particularly when compared to the more convenient and resource-efficient approach of empiric activity administration. This review outlines the fundamental principles, procedures, and methodologies related to image activity quantification and dosimetry with a specific focus on 177Lutetium-based radiopharmaceuticals.

3.
Front Nucl Med ; 4: 1232135, 2024.
Article in English | MEDLINE | ID: mdl-39355219

ABSTRACT

Introduction: Single-photon emission computed tomography (SPECT) and positron emission tomography (PET) are non-invasive nuclear medicine techniques that can identify areas of abnormal myocardial perfusion. We assessed the prevalence of cardiovascular risk factors in patients with suspected coronary artery disease (CAD) undergoing SPECT or PET stress myocardial perfusion imaging (MPI). Based on significant risk factors associated with an abnormal MPI, we developed a nomogram for each cohort as a pretest that would be helpful in decision-making for clinicians. Methods: A total of 6,854 patients with suspected CAD who underwent stress myocardial perfusion imaging by SPECT or PET/CT was studied. As part of the baseline examination, clinical teams collected information on traditional cardiovascular risk factors: age, gender, body mass index, angina, dyspnea, diabetes, hypertension, hyperlipidemia, family history of CAD, and smoking. Results: The prevalence of cardiovascular risk factors was different in the two cohorts of patients undergoing SPECT (n = 4,397) or PET (n = 2,457) myocardial perfusion imaging. A statistical significance was observed in both cohorts for age, gender, and diabetes. At multivariable analysis, only age and male gender were significant covariates in both cohorts. The risk of abnormal myocardial perfusion imaging related to age was greater in patients undergoing PET (odds ratio 4% vs. 1% per year). In contrast, male gender odds ratio was slightly higher for SPECT compared to PET (2.52 vs. 2.06). In the SPECT cohort, smoking increased the risk of abnormal perfusion of 24%. Among patients undergoing PET, diabetes and hypertension increased the risk of abnormal perfusion by 63% and 37%, respectively. For each cohort, we obtained a nomogram by significant risk factors at multivariable logistic regression. The area under the receiver operating characteristic curve associated with the nomogram was 0.67 for SPECT and 0.73 for the PET model. Conclusions: Patients with suspected CAD belonging to two different cohorts undergoing SPECT or PET stress myocardial perfusion imaging can have different cardiovascular risk factors associated with a higher risk of an abnormal MPI study. As crude variables, age, gender, and diabetes were significant for both cohorts. Net of the effect of other covariates, age and gender were the only risk factors in common between the two cohorts. Furthermore, smoking and type of stress test were significant for the SPECT cohort, where as diabetes and hypertension were significant for the PET cohort. Nomograms obtained by significant risk factors for the two cohorts can be used by clinicians to evaluate the risk of an abnormal study.

4.
EJNMMI Phys ; 11(1): 80, 2024 Oct 02.
Article in English | MEDLINE | ID: mdl-39356406

ABSTRACT

BACKGROUND: Deep learning (DL)-based denoising has been proven to improve image quality and quantitation accuracy of low dose (LD) SPECT. However, conventional DL-based methods used SPECT images with mixed frequency components. This work aims to develop an integrated multi-frequency denoising network to further enhance LD myocardial perfusion (MP) SPECT denoising. METHODS: Fifty anonymized patients who underwent routine 99mTc-sestamibi stress SPECT/CT scans were retrospectively recruited. Three LD datasets were obtained by reducing the 10 s acquisition time of full dose (FD) SPECT to be 5, 2 and 1 s per projection based on the list mode data for a total of 60 projections. FD and LD projections were Fourier transformed to magnitude and phase images, which were then separated into two or three frequency bands. Each frequency band was then inversed Fourier transformed back to the image domain. We proposed a 3D integrated attention-guided multi-frequency conditional generative adversarial network (AttMFGAN) and compared with AttGAN, and separate AttGAN for multi-frequency bands denoising (AttGAN-MF).The multi-frequency FD and LD projections of 35, 5 and 10 patients were paired for training, validation and testing. The LD projections to be tested were separated to multi-frequency components and input to corresponding networks to get the denoised components, which were summed to get the final denoised projections. Voxel-based error indices were measured on the cardiac region on the reconstructed images. The perfusion defect size (PDS) was also analyzed. RESULTS: AttGAN-MF and AttMFGAN have superior performance on all physical and clinical indices as compared to conventional AttGAN. The integrated AttMFGAN is better than AttGAN-MF. Multi-frequency denoising with two frequency bands have generally better results than corresponding three-frequency bands methods. CONCLUSIONS: AttGAN-MF and AttMFGAN are promising to further improve LD MP SPECT denoising.

5.
Med Phys ; 2024 Sep 03.
Article in English | MEDLINE | ID: mdl-39225550

ABSTRACT

BACKGROUND: Deep learning is the primary method for conducting automated analysis of SPECT bone scintigrams. The lack of available large-scale data significantly hinders the development of well-performing deep learning models, as the performance of a deep learning model is positively correlated with the size of the dataset used. Therefore, there is an urgent demand for an automated data generation method to enlarge the dataset of SPECT bone scintigrams. PURPOSE: We introduce a deep learning-based generation model that can generate realistic but not identical samples from the original SPECT bone scintigrams. METHODS: Following the generative adversarial learning architecture, a bone metastasis scintigram generation model christened BMS-Gen is proposed. First, BMS-Gen takes multiple input conditions and employs multi-receptive field learning to ensure that the generated samples are as realistic as possible. Second, BMS-Gen adopts generative adversarial learning to retain the diversity of the generated samples. Last, BMS-Gen uses a two-stage training strategy to improve the quality of the generated samples. RESULTS: Experimental evaluation conducted on a set of clinical data of SPECT BM scintigrams has shown the performance of the proposed BMS-Gen, achieving the best overall scores of 1678.0, 69.33, and 19.51 for FID (Fréchet Inception Distance), MSE (Mean Square Error), and PSNR (Peak Signal-to-Noise Ratio) metrics. The introduction of samples generated by BMS-Gen contributes a maximum (minimum) increase of 3.01% (0.15%) on the F-1 score and a maximum (minimum) increase of 6.83% (2.21%) on the DSC score for the image classification and segmentation tasks, respectively. CONCLUSIONS: The proposed BMS-Gen model can be used as a promising tool for augmenting the data of bone scintigrams, greatly facilitating the development of deep learning-based automated analysis of SPECT bone scintigrams.

6.
Mov Disord ; 2024 Sep 03.
Article in English | MEDLINE | ID: mdl-39225564

ABSTRACT

BACKGROUND: The cardinal motor symptoms of Parkinson's disease (PD) include rigidity, bradykinesia, and rest tremor. Rigidity and bradykinesia correlate with contralateral nigrostriatal degeneration and striatal dopamine deficit, but association between striatal dopamine function and rest tremor has remained unclear. OBJECTIVE: The aim of this study was to investigate the possible link between dopamine function and rest tremor using Parkinson's Progression Markers Initiative dataset, the largest prospective neuroimaging cohort of patients with PD. METHODS: Clinical, [123I]N-ω-fluoropropyl-2ß-carbomethoxy-3ß-(4-iodophenyl)nortropane ([123I]FP-CIT) single photon emission computed tomography (SPECT), and structural magnetic resonance imaging data from 354 early PD patients and 166 healthy controls were included in this study. We employed a novel approach allowing nonlinear registration of individual scans accurately to a standard space and voxelwise analyses of the association between motor symptoms and striatal dopamine transporter (DAT) binding. RESULTS: Severity of both rigidity and bradykinesia was negatively associated with contralateral striatal DAT binding (PFWE < 0.05 [FWE, family-wise error corrected]). However, rest tremor amplitude was positively associated with increased ipsilateral DAT binding (PFWE < 0.05). The association between rest tremor and binding remained the same controlling for Hoehn & Yahr stage, Movement Disorder Society Unified Parkinson's Disease Rating Scale (MDS-UPDRS) part III score, bradykinesia-rigidity score, or motor phenotype. The association between rest tremor and binding was independent of bradykinesia-rigidity and replicated using 2-year follow-up data (PFWE < 0.05). CONCLUSION: In agreement with the existing literature, we did not find a consistent association between rest tremor and contralateral dopamine defect. However, our results demonstrate a link between rest tremor and increased or less decreased ipsilateral DAT binding. Our findings provide novel information about the association between dopaminergic function and parkinsonian rest tremor. © 2024 The Author(s). Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.

7.
EJNMMI Rep ; 8(1): 27, 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39218826

ABSTRACT

PURPOSE: To investigate the performance of dynamic 3D diuretic renal scintigraphy using a hybrid whole body CZT SPECT/CT for the evaluation of acute ureteric obstruction in patients with urinary stone disease. METHODS: 20 patients who presented to the Emergency Department with acute renal colic due to urinary stone disease confirmed by means of CT were prospectively included. Three observers evaluated and graded hydronephrosis, hydroureter, perirenal stranding, and thickening of the renal fascia from the CT as well as the renal scintigraphy curves from the dynamic SPECT study. The normalized residual activity from dynamic SPECT was analysed at 16 min in all patients and at 20 min in suspected obstruction. RESULTS: Renal scintigraphy curves showed a sensitivity of 100%, specificity of 93%, PPV 83% and a NPV 100% for obstruction, while normalized residual activity showed a sensitivity of 100%, specificity of 73%, PPV 56% and a NPV 100%. All patients presented at least 2 secondary signs of obstruction on the CT, showing a PPV of only 25% for obstruction. CONCLUSION: Dynamic 3D diuretic renal scintigraphy CZT SPECT/CT provides valuable functional and anatomical information from one single examination. The combination of pathological renogram curves and high normalized residual activity values provide the most valuable imaging information to determine the presence of acute ureteric obstruction. The secondary signs of obstruction observed on CT are not specific and should not be used to confirm or discard obstruction in patients with urinary stone disease. TRIAL REGISTRATION: ISRCTN15338358. Registration date 03/01/2024. Retrospectively registered. https://www.isrctn.com/ISRCTN15338358?q=miguel%20ochoa%20figueroa&filters=&sort=&offset=1&totalResults=2&page=1&pageSize=10.

8.
Open Med (Wars) ; 19(1): 20241027, 2024.
Article in English | MEDLINE | ID: mdl-39247440

ABSTRACT

Purpose: This study aimed to assess the biodistribution and bioactivity of the affibody molecular probe 99mTc-(HE)3ZHER2:V2, prepared by genetic recombination, and to investigate its potential for targeted human epidermal growth factor receptor 2 (HER2) imaging in SKOV3 ovarian cancer and MDA-MB-361 breast cancer xenografts. Methods: Affibody molecules were generated through genetic recombination. The radiochemical purity of the 99mTc-labeled HER2 affibody was determined using reverse phase high performance liquid chromatography (RP-HPLC). Evaluation of HER2 affinity in SKOV3 ovarian cancer cells and MDA-MB-361 breast cancer cells (HER2-positive) was conducted by calculating equilibrium dissociation constants. Biodistribution of the 99mTc-labeled affibody molecular probe was assessed in Balb/c mice bearing SKOV3 tumors. Tumor targeting specificity was evaluated in Balb/c mice using SKOV3, MDA-MB-361, and AT-3 (HER2-negative) xenografts. Results: Affibody (HE)3ZHER2:V2, generated through recombinant gene expression, was successfully labeled with 99mTc, achieving a radiochemical purity of (96.0 ± 1.7)% (n = 3) as determined by RP-HPLC. This molecular probe exhibited specific binding to HER2-positive SKOV3 cells, demonstrating intense radioactive uptake. Biodistribution analysis showed rapid accumulation of 99mTc-(HE)3ZHER2:V2 in HER2-positive tumors post-administration, primarily clearing through the urinary system. Single-photon emission computed tomography imaging conducted 1-3 h after intravenous injection of 99mTc-(HE)3ZHER2:V2 into HER2-positive SKOV3 and MDA-MB-361 nude mouse models confirmed targeted uptake of the molecular probe by the tumors. Conclusions: The molecular probe 99mTc-(HE)3ZHER2:V2 developed in this study effectively targets HER2 for imaging HER2-positive SKOV3 and MDA-MB-361 xenografts in vivo. It exhibits rapid blood clearance without evident toxic effects, suggesting its potential as a valuable marker for detecting HER2 expression in tumor cells.

9.
Curr Radiopharm ; 2024 Aug 27.
Article in English | MEDLINE | ID: mdl-39253932

ABSTRACT

BACKGROUND: Gated SPECT is an established technique for assessment of left ventricular function in cardiovascular disease patients. However, there is little information about the influence of diabetes mellitus on gated SPECT parameters. This study was established to assess gated SPECT parameters in Diabetes Mellitus (DM) and non-diabetes mellitus (non-DM) patients with normal Myocardial Perfusion Imaging (MPI). METHODS: In this analytical cross-sectional study, 314 patients (157 DM, 157 non-DM) with normal MPI were enrolled. Prevalence of risk factors for CAD like hypertension (HTN), and dyslipidemia were found to be significantly higher (p <0.01) in DM patients compared to non-DM. RESULTS: No statistically significant difference was observed among the TID, ESV, EDV, PFR, TTPF, and Wall Thickness (WT) parameters between DM and non-DM patients. Wall motion (Wm) in DM patients was significantly higher compared to non-DM patients. (3.9 ± 0.51 vs. 2.69 ± 0.48 for DM and non-DM patients, respectively, p-value:0.01). Also, there was no significant difference in Wm in the two groups with and without HTN. This shows the independent effect of DM on the Wm. CONCLUSION: This study believes that the Wm parameter should be noted for the early diagnosis or prevention of heart disease in DM patients. These findings can indicate the gradual changes in the movements of the left ventricle and the beginning of the progression of diabetic cardiomyopathy.

10.
Ann Nucl Med ; 2024 Sep 10.
Article in English | MEDLINE | ID: mdl-39254922

ABSTRACT

PURPOSE: This study evaluated the usefulness of SUV analysis of 99mTc-galactosyl human serum albumin (99mTc-GSA) scintigraphy including SUV analysis of the cardiac blood pool normalized by blood volume as a predictor of short-term survival in severe liver failure. PATIENTS AND METHODS: We enrolled 24 patients with severe liver failure who underwent 99mTc-GSA scintigraphy and were admitted to the intensive care unit. Patients were divided into survival and non-survival groups at 7, 14, and 28 days from the performance of 99mTc-GSA scintigraphy. From SPECT images we calculated SUVs of the cardiac blood pool, performing normalization for body weight, lean body weight, Japanese lean body weight, and blood volume and we calculated SUVs of the liver, normalizing by body weight, lean body weight, and Japanese lean body weight. We also calculated the uptake ratio of the heart at 15 min to that at 3 min (HH15) and the uptake ratio of the liver at 15 min to the liver plus the heart at 15 min (LHL15) from planar images of 99mTc-GSA scintigraphy. RESULTS: There were significant differences between the 7 day survival and non-survival groups for all SUVs of the heart and the liver and HH15, for 14 day survival groups in SUVs of the heart normalized by Japanese lean body weight and blood volume, and no significant differences between 28 day survival groups for any SUVs, HH15, or LHL15. Although the difference was not significant, SUV analysis of the heart normalized by blood volume showed the highest value for the area under the receiver-operating-characteristics curve for both 7 day and 14 day survival. CONCLUSION: SUV analysis of 99mTc-GSA including SUV analysis of cardiac blood pool normalized by blood volume is of value for prediction of short-term survival in cases with severe liver failure.

11.
Radiol Med ; 2024 Sep 10.
Article in English | MEDLINE | ID: mdl-39256298

ABSTRACT

PURPOSE: The objective of this study was to investigate the role of myocardial perfusion imaging (MPI) stress tests using stress cardiac magnetic resonance (sCMR) and single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in non-cardiac surgery (NCS) pre-operatory management. MATERIALS AND METHODS: This monocentric retrospective study enrolled patients with coronary artery disease or a minimum of two cardiovascular risk factors undergoing intermediate-to-high-risk non-cardiac surgeries. The primary composite endpoint comprised cardiac death, cardiogenic shock, acute coronary syndromes (ACS), and cardiogenic pulmonary edema occurring within 30 days after surgery, while the secondary endpoint was ACS. RESULTS: A total of 1590 patients were enrolled; among them, 669 underwent a MPI stress test strategy (sCMR: 287, SPECT-MPI: 382). The incidence of 30-day cardiac events was lower in the stress-tested group compared to the non-stress-tested group (1.2% vs. 3.4%; p 0.006). Adopting a stress test strategy showed a significant reduction in the risk of the composite endpoint (OR: 0.33, 95% CI: 0.15-0.76, p 0.009) and ACS (OR: 0.41, 95% CI: 0.17-0.98, p 0.046) at multivariable analysis, with similar cardiac events rate between stress CMR and SPECT (1.1% vs. 1.3%, p 0.756). Stress CMR showed a greater accuracy to predict coronary artery revascularizations (sCMR c-statistic: 0.95, ischemic cut-point: 5.5%; SPECT c-statistic: 0.85, ischemic cut-point: 7.5%). CONCLUSION: Stress test strategy is related to a lower occurrence of cardiac events in high-risk patients scheduled for intermediate-to-high-risk non-cardiac surgeries. Both sCMR and SPECT-MPI comparably reduce the likelihood of cardiac complications, albeit sCMR offers greater accuracy in predicting coronary artery revascularization.

12.
Article in English | MEDLINE | ID: mdl-39259227

ABSTRACT

The introduction of smaller footprint, more sensitive Cadmium-Zinc-Telluride (CZT)-based detectors with improved spatial and energy resolution has enabled the design of innovative full-ring 360° CZT SPECT/CT systems (e.g., VERITON® and StarGuide™). With this transformative technology now aiming to become mainstream in clinical practice, several critical questions need to be addressed. This EANM position paper provides practical recommendations on how to use these devices for routine bone SPECT/CT studies, facilitating the transition from traditional planar whole-body imaging and conventional SPECT/CT to these novel systems. In particular, initial guidance is provided on imaging acquisition and reporting workflows, image reconstruction, and CT acquisition parameters. Given the emerging nature of this technology, the available evidence base is still limited, and the proposed adaptations in workflows and scan protocols will likely evolve before being integrated into definitive guidelines. In the meantime, this EANM position paper serves as a comprehensive guide for integrating these advanced hybrid SPECT/CT imaging systems into clinical practice and outlining areas for further study.

13.
J Nucl Cardiol ; : 102031, 2024 Sep 02.
Article in English | MEDLINE | ID: mdl-39233111

ABSTRACT

- Diffuse and patchy myocardial uptake of Tc-99m PYP is well established in cases of ATTR-CA. - Chronic myocardial infarction leads to regional myocardial thinning and lack of vascular supply can present as regional sparing 'cold spot' on Tc-99m PYP imaging. - The absence of Tc-99m PYP uptake in vascular regions should raise the possibility of underlying scar.

14.
Knee ; 51: 58-64, 2024 Sep 04.
Article in English | MEDLINE | ID: mdl-39236638

ABSTRACT

BACKGROUND: An open wedge high tibial osteotomy (OWHTO) may lead to gait alteration, which change the contact loading in the contralateral knee, while clear evidence about the impact on contralateral knee still lacks. The purpose of the current study was to evaluate the change in scintigraphic uptake using SPECT-CT in the medial compartment of the contralateral knee following OWHTO. METHODS: Contralateral radiographic measurements were performed for patients with medial osteoarthritis and varus malalignment of >5° treated with OWHTO in this retrospective analysis. The medial compartmental changes according to SPECT/CT analysis before and 1-year after OWHTO were evaluated on the contralateral side. RESULTS: The study comprised 72 patients. The mean preoperative mechanical femorotibial angle was a mean varus of 7.6° (range, 5.1° - 13.0°), corrected to a mean valgus of 2.5° (range, 1.9° - -8.5°) postoperatively. The average grading of the scintigraphic uptakes in the medial compartment of the contralateral knee was significantly decreased 1 year postoperatively than after the surgery (from 2.8 ± 0.4 to 2.1 ± 0.6, p < 0.001). Measurable differences in varus alignment on radiographs of the contralateral limb were identified. The preoperative mechanical axis value decreased from 8.0° ± 2.4° to 6.7° ± 2.6° at the 3-month postoperative visit (p = 0.011). The overall decrease in varus alignment remained at the 2-year final postoperative follow-up. CONCLUSION: Alignment correction by OWHTO results in reducing scintigraphy uptakes in medial compartment and improvement in mechanical alignment of the contralateral knee. LEVEL OF EVIDENCE: Therapeutic Level IV.

15.
Clin Podiatr Med Surg ; 41(4): 649-663, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39237177

ABSTRACT

Use of SPECT/CT (Single Photon Emission Computed Tomography/Computed Tomography) is increasing providing additional information in patients with inconclusive clinical examination and unremarkable imaging findings presenting with chronic pain after total ankle arthroplasty. To differentiate the cause of pain after total ankle arthroplasty can be challenging. SPECT/CT combines structural and metabolic imaging as a hybrid tool leading to higher specificity and overall diagnostic accuracy presumably in cases of gutter impingement, prosthetic loosening, and osteoarthritis of adjacent joints. Moreover, SPECT/CT can complement diagnostic work up in periprosthetic joint infections. Basal tracer enhancement has to be considered for the interpretation of imaging findings.


Subject(s)
Ankle Joint , Arthroplasty, Replacement, Ankle , Humans , Arthroplasty, Replacement, Ankle/adverse effects , Ankle Joint/surgery , Ankle Joint/diagnostic imaging , Single Photon Emission Computed Tomography Computed Tomography , Osteoarthritis/surgery , Osteoarthritis/diagnostic imaging , Tomography, Emission-Computed, Single-Photon , Prosthesis Failure , Prosthesis-Related Infections/diagnostic imaging , Prosthesis-Related Infections/etiology , Joint Prosthesis/adverse effects
16.
Diagnostics (Basel) ; 14(17)2024 Sep 09.
Article in English | MEDLINE | ID: mdl-39272781

ABSTRACT

Primary: aldosteronism is a frequent cause of secondary hypertension. With access to specialized care, an increasing number of patients with aldosteronism are being identified. Primary aldosteronism is treatable by adrenal surgery if aldosterone excess originates from one of the two, and not from both, adrenals. Bilateral hyperplasia requires lifelong mineralocorticoid receptor antagonist treatment. Up till now, adrenal venous sampling (AVS) has been widely used to distinguish between one-sided and two-sided aldosterone overproduction and patient selection for surgery. AVS is an invasive technique, and the unsuccessful sampling of the right adrenal vein during AVS often prevents side comparison, making the AVS procedure useless. Molecular imaging using [131I]6ß-iodomethyl-19-norcholesterol with SPECT CT imaging (SPECT/CT) may be a potential alternative. METHODS: In 42 consecutive patients with confirmed primary aldosteronism, molecular imaging has been performed. After dexamethasone suppression of the non-affected adrenal tissue, 37 MBq [131I]6ß-iodomethyl-19-norcholesterol was injected i.v., and SPECT/CT images were taken 7 days later. Based on the visual evaluation of the images by two nuclear medicine specialists, patients with one-sided tracer accumulation underwent adrenalectomy. To identify a SPECT/CT parameter that best characterizes the side difference, the maximum counts and the mean counts of spherical VOIs were analyzed. RESULTS: Of the 42 patients, 24 had one-sided aldosterone overproduction by SPECT/CT. After surgical removal of the involved adrenal, all 24 patients with SPECT/CT-identified unilateral aldosteronism achieved biochemical cure, defined as a normalized potassium level combined with an aldosterone-to-renin ratio ≤ 30. To identify the best measurable parameter of SPECT/CT side difference, the mean counts and maximum counts of a series of spherical VOIs of different diameters were analyzed. The ratio of the mean counts of 3 cm spherical VOIs of the right and left adrenal regions (lateralization index) was the best discriminator; a ratio of ≥1.29 was characteristic of one-sided disease, without overlap between the one-sided and two-sided patient groups. CONCLUSIONS: [131I]6ß-iodomethyl-19-norcholesterol SPECT/CT with a count-based image interpretation and side-ratio calculation may be an equipollent non-invasive substitute for adrenal venous sampling in the lateralization of mineralocorticoid overproduction. It reliably identifies unilateral disease and facilitates patients' selection for surgical intervention. If confirmed by others, this functional imaging may replace AVS when lateralization is required for management decisions in primary aldosteronism.

17.
Glob Health Med ; 6(4): 244-250, 2024 Aug 31.
Article in English | MEDLINE | ID: mdl-39219587

ABSTRACT

The aim of this study is to estimate eye lens exposure dose when handling radiopharmaceuticals and interacting with patients receiving radiopharmaceuticals, and to verify the usefulness of X-ray protective goggles in mitigating such radiation exposure using phantoms. To evaluate radiation exposure during the handling of radiopharmaceuticals, we employed a fluorescent glass dosimeter to measure the radiation doses associated with 99mTc, 123I, 131I, 111In, and 18F at distances of 30 cm and 60 cm, followed by calculation of the 3 mm dose equivalent rate (3DER). We then estimated the dose reduction rates for various scenarios, including the use of syringe shields and X-ray protective goggles with lead equivalences of 0.07, 0.15, 0.75, and 0.88 mmPb, as well as their combined application. X-ray protective goggles with lead equivalence of 0.75 mmPb outperformed those with 0.07 mmPb and 0.15 mmPb, for all radionuclides and at both source distances. X-ray protective goggles with 0.88 mmPb outperformed those with 0.75 mmPb during handling of 131I and 111In at a distance of 30 cm. In the remaining scenarios, X-ray protective goggles with 0.88 mmPb resulted in marginal reductions or no discernible additional effects. The overall shielding effect of X-ray protective goggles was less pronounced for 131I and 18F, but the combined use of a syringe shield with X-ray protective goggles with 0.75 or 0.88 mmPb improved the dose reduction rate for all scenarios. In simulating patient care, X-ray protective goggles with 0.88 mmPb demonstrated a dose reduction effect of approximately 50% or more. X-ray protective goggles could reduce the 3DER for the eye lens, and were more effective when combined with a syringe shield. It is valid to use a lead equivalence of 0.88 mmPb to fully harness the protective capabilities of X-ray shielding goggles when dealing with all five types of nuclides in clinical settings.

18.
Epilepsy Behav ; 159: 110014, 2024 Oct.
Article in English | MEDLINE | ID: mdl-39236374

ABSTRACT

PURPOSE: To analyze the characteristics of cerebral blood flow changes of poor sleep quality in people with epilepsy(PWE). METHODS: 90 PWE treated in The General Hospital of Ningxia Medical University from December 2021 to September 2023 were divided into poor sleep quality group (PSQG) and good sleep quality group (GSQG) according to the Chinese version of the Pittsburgh Sleep Quality Index (CPSQI), to compare the differences in cerebral perfusion between the two groups of patients, so as to summarize the characteristics of cerebral blood flow changes of poor sleep quality in PWE. RESULTS: The positive rate of interictal single-photon emission computed tomography/computed tomography (SPECT/CT) was 76.7 %(69/90), which showed localized cerebral hypoperfusion. There was no statistical difference between the two groups of PSQG (N=29) and GSQG (N=61) in terms of the positive rate of SPECT/CT, the number of hypoperfusion foci, and the range of hypoperfusion foci. In PSQG and GSQG, 9 patients(31.0 %) and 6 patients(9.8 %) showed hypoperfusion in the right parietal lobe, respectively, and the difference between the two groups was statistically significant (P=0.017). There was no statistical difference the rate of the interictal epileptiform discharges (IEDs) and the brain area of IEDs in electroencephalography(EEG) between the two groups. CONCLUSION: SPECT/CT of poor sleep quality in PWE demonstrated hypoperfusion in the right parietal lobe.


Subject(s)
Cerebrovascular Circulation , Epilepsy , Single Photon Emission Computed Tomography Computed Tomography , Humans , Female , Male , Adult , Epilepsy/diagnostic imaging , Epilepsy/physiopathology , Epilepsy/complications , Middle Aged , Cerebrovascular Circulation/physiology , Young Adult , Adolescent , Brain/diagnostic imaging , Brain/physiopathology , Sleep Quality , Aged , Electroencephalography , Sleep Wake Disorders/diagnostic imaging , Sleep Wake Disorders/physiopathology , Sleep Wake Disorders/etiology
19.
BMC Med Imaging ; 24(1): 236, 2024 Sep 09.
Article in English | MEDLINE | ID: mdl-39251959

ABSTRACT

BACKGROUND: To evaluate the clinical performance of two deep learning methods, one utilizing real clinical pairs and the other utilizing simulated datasets, in enhancing image quality for two-dimensional (2D) fast whole-body scintigraphy (WBS). METHODS: A total of 83 patients with suspected bone metastasis were retrospectively enrolled. All patients underwent single-photon emission computed tomography (SPECT) WBS at speeds of 20 cm/min (1x), 40 cm/min (2x), and 60 cm/min (3x). Two deep learning models were developed to generate high-quality images from real and simulated fast scans, designated 2x-real and 3x-real (images from real fast data) and 2x-simu and 3x-simu (images from simulated fast data), respectively. A 5-point Likert scale was used to evaluate the image quality of each acquisition. Accuracy, sensitivity, specificity, and the area under the curve (AUC) were used to evaluate diagnostic efficacy. Learned perceptual image patch similarity (LPIPS) and the Fréchet inception distance (FID) were used to assess image quality. Additionally, the count-level consistency of WBS was compared between the two models. RESULTS: Subjective assessments revealed that the 1x images had the highest general image quality (Likert score: 4.40 ± 0.45). The 2x-real, 2x-simu and 3x-real, 3x-simu images demonstrated significantly better quality than the 2x and 3x images (Likert scores: 3.46 ± 0.47, 3.79 ± 0.55 vs. 2.92 ± 0.41, P < 0.0001; 2.69 ± 0.40, 2.61 ± 0.41 vs. 1.36 ± 0.51, P < 0.0001), respectively. Notably, the quality of the 2x-real images was inferior to that of the 2x-simu images (Likert scores: 3.46 ± 0.47 vs. 3.79 ± 0.55, P = 0.001). The diagnostic efficacy for the 2x-real and 2x-simu images was indistinguishable from that of the 1x images (accuracy: 81.2%, 80.7% vs. 84.3%; sensitivity: 77.27%, 77.27% vs. 87.18%; specificity: 87.18%, 84.63% vs. 87.18%. All P > 0.05), whereas the diagnostic efficacy for the 3x-real and 3x-simu was better than that for the 3x images (accuracy: 65.1%, 66.35% vs. 59.0%; sensitivity: 63.64%, 63.64% vs. 64.71%; specificity: 66.67%, 69.23% vs. 55.1%. All P < 0.05). Objectively, both the real and simulated models achieved significantly enhanced image quality from the accelerated scans in the 2x and 3x groups (FID: 0.15 ± 0.18, 0.18 ± 0.18 vs. 0.47 ± 0.34; 0.19 ± 0.23, 0.20 ± 0.22 vs. 0.98 ± 0.59. LPIPS: 0.17 ± 0.05, 0.16 ± 0.04 vs. 0.19 ± 0.05; 0.18 ± 0.05, 0.19 ± 0.05 vs. 0.23 ± 0.04. All P < 0.05). The count-level consistency with the 1x images was excellent for all four sets of model-generated images (P < 0.0001). CONCLUSIONS: Ultrafast 2x speed (real and simulated) images achieved comparable diagnostic value to that of standardly acquired images, but the simulation algorithm does not necessarily reflect real data.


Subject(s)
Bone Neoplasms , Deep Learning , Tomography, Emission-Computed, Single-Photon , Whole Body Imaging , Humans , Whole Body Imaging/methods , Female , Male , Retrospective Studies , Middle Aged , Aged , Tomography, Emission-Computed, Single-Photon/methods , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/secondary , Sensitivity and Specificity , Adult , Aged, 80 and over
20.
Front Oncol ; 14: 1414337, 2024.
Article in English | MEDLINE | ID: mdl-39286020

ABSTRACT

The objective of this review is to examine the potential benefits and challenges of CT-based lung function imaging in radiotherapy over recent decades. This includes reviewing background information, defining related concepts, classifying and reviewing existing studies, and proposing directions for further investigation. The lung function imaging techniques reviewed herein encompass CT-based methods, specifically utilizing phase-resolved four-dimensional CT (4D-CT) or end-inspiratory and end-expiratory CT scans, to delineate distinct functional regions within the lungs. These methods extract crucial functional parameters, including lung volume and ventilation distribution, pivotal for assessing and characterizing the functional capacity of the lungs. CT-based lung ventilation imaging offers numerous advantages, notably in the realm of thoracic radiotherapy. By utilizing routine CT scans, additional radiation exposure and financial burdens on patients can be avoided. This imaging technique also enables the identification of different functional areas of the lung, which is crucial for minimizing radiation exposure to healthy lung tissue and predicting and detecting lung injury during treatment. In conclusion, CT-based lung function imaging holds significant promise for improving the effectiveness and safety of thoracic radiotherapy. Nevertheless, challenges persist, necessitating further research to address limitations and optimize clinical utilization. Overall, this review highlights the importance of CT-based lung function imaging as a valuable tool in radiotherapy planning and lung injury monitoring.

SELECTION OF CITATIONS
SEARCH DETAIL