Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22.613
Filter
1.
Article in English | MEDLINE | ID: mdl-39040523

ABSTRACT

The new Kyoto guidelines for the management of intraductal papillary mucinous neoplasm (IPMN) provide evidence-based recommendations for the diagnosis and treatment of IPMN. Endoscopic ultrasonography (EUS) is a diagnostic modality with a high spatial resolution that allows detailed observation and obtaining cyst fluid or tissue samples via EUS-guided fine needle aspiration (EUS-FNA). Currently, EUS is an indispensable examination method for the diagnosis of pancreatic diseases. On the other hand, there have been concerns that EUS imaging tends to be highly operator-dependent, and may lack objectivity. Previous guidelines have assigned EUS as an option for patients with worrisome features. However, recent reports indicate that the sensitivity of EUS for the diagnosis of mural nodules (MNs) is more than 90%, comparable or superior to that of contrast-enhanced computed tomography or magnetic resonance cholangiopancreatography. The specific advantages of EUS in the diagnosis of IPMN are: (1) high spatial resolution imaging for the diagnosis of MNs, (2) contrast-enhanced EUS for differentiation of intra-cystic MNs from mucous clots, and (3) pathological diagnosis using EUS-FNA and differential diagnosis of a pancreatic cystic tumor by cystic fluid analysis. In order to utilize EUS in the diagnosis of IPMN, endoscopists are required to have the skills to provide sufficiently objective imaging findings.

2.
J Biomed Opt ; 30(Suppl 1): S13703, 2025 Jan.
Article in English | MEDLINE | ID: mdl-39034959

ABSTRACT

Significance: Standardization of fluorescence molecular imaging (FMI) is critical for ensuring quality control in guiding surgical procedures. To accurately evaluate system performance, two metrics, the signal-to-noise ratio (SNR) and contrast, are widely employed. However, there is currently no consensus on how these metrics can be computed. Aim: We aim to examine the impact of SNR and contrast definitions on the performance assessment of FMI systems. Approach: We quantified the SNR and contrast of six near-infrared FMI systems by imaging a multi-parametric phantom. Based on approaches commonly used in the literature, we quantified seven SNRs and four contrast values considering different background regions and/or formulas. Then, we calculated benchmarking (BM) scores and respective rank values for each system. Results: We show that the performance assessment of an FMI system changes depending on the background locations and the applied quantification method. For a single system, the different metrics can vary up to ∼ 35 dB (SNR), ∼ 8.65 a . u . (contrast), and ∼ 0.67 a . u . (BM score). Conclusions: The definition of precise guidelines for FMI performance assessment is imperative to ensure successful clinical translation of the technology. Such guidelines can also enable quality control for the already clinically approved indocyanine green-based fluorescence image-guided surgery.


Subject(s)
Benchmarking , Molecular Imaging , Optical Imaging , Phantoms, Imaging , Signal-To-Noise Ratio , Molecular Imaging/methods , Molecular Imaging/standards , Optical Imaging/methods , Optical Imaging/standards , Image Processing, Computer-Assisted/methods
3.
Front Pediatr ; 12: 1429490, 2024.
Article in English | MEDLINE | ID: mdl-39350792

ABSTRACT

Wandering spleen (WS) concurrent with splenic pedicle torsion and infarction has been described rarely. We reported our experience in diagnosing and treating such a condition in a 16-year-old girl with acute abdominal pain. A plain CT scan showed the wandering of the spleen from the left upper quadrant. Contrast-enhanced CT indicated dilatation and distortion in the splenic vein, a counterclockwise "whirl sign" in the splenic pedicle, pancreatic tail torsion, and splenic infarction. The patient was diagnosed with WS combined with splenic pedicle torsion and splenic infarction and underwent splenectomy for treatment. She showed a satisfactory outcome during the follow-up. To enhance our understanding of it, we performed a comprehensive literature research to summarize the clinical manifestations, treatment options, and outcomes among adolescent patients.

4.
Cureus ; 16(8): e68160, 2024 Aug.
Article in English | MEDLINE | ID: mdl-39350853

ABSTRACT

BACKGROUND: Previous reports attempted to evaluate bladder cancer using 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) by washing out the excreted FDG with a diuretic. The purpose of this study was to evaluate the value of diuretic FDG PET/plain CT (drtPET/CT) and diuretic FDG PET/contrast-enhanced CT (drtPET/ceCT) in the assessment of upper urinary tract cancers. MATERIALS AND METHODS: A total of 66 patients underwent drtPET/CT for suspected upper urinary tract cancer (UUTC). The study targeted 29 patients who were strongly suspected of having UUTC and underwent magnetic resonance imaging (MRI) of the upper urinary tract. A total of 29 (24 male, five female) patients, with a mean ± SD age of 73 ± 3 (range, 43-84) years, had a suspected neoplasm in the upper urinary tract. They underwent FDG PET/plain and contrast-enhanced CT before and after a diuretic and MRI including diffusion-weighted imaging (DWI). A urologist and a physician board-certified in nuclear medicine and radiology independently interpreted the standard PET/CT (stdPET/CT), drtPET/CT, drtPET/ceCT, ceCT, and MRI with DWI images. Interobserver agreement and the diagnostic performance of each modality were evaluated. RESULTS: The kappa values of stdPET/CT, drtPET/CT, drtPET/ceCT, ceCT, and MRI were 0.381, 0.567, 0.7031, 0.448, and 0.185, respectively, with drtPET/ceCT showing the highest kappa value and the only one with good interobserver agreement (>60%). The area under the curve of drtPET/ceCT was 0.92, which was significantly higher than those of stdPET/CT (P=0.027) and MRI (P=0.047). CONCLUSIONS: In the present study, drtPET/ceCT had the best diagnostic performance and the highest interobserver agreement for detecting upper urinary tract urothelial cancers.

5.
World J Nephrol ; 13(3): 98300, 2024 Sep 25.
Article in English | MEDLINE | ID: mdl-39351183

ABSTRACT

Acute pyelonephritis (APN) is a bacterial infection resulting in kidney inflammation, typically arising as a complication of an ascending urinary tract infection that ascends from the bladder to the kidneys. Clinical diagnosis is generally based on clinical and laboratory findings. Recent guidelines recommend not performing diagnostic imaging unless a complicated APN is suspected or the infection affects high-risk patients such as the elderly, immunocompromised individuals, or diabetics. Contrast-enhanced ultrasound (CEUS) is a valuable tool in both the diagnosis and follow-up of APN. It aids in distinguishing small simple nephritic involvement from abscess complications and monitoring their evolution over time during antibiotic therapy. Given its lack of ionizing radiation and nephrotoxicity, CEUS is a valid diagnostic modality for approaching and monitoring pyelonephritis, improving early identification and characterization of inflammatory lesions. This review aims to summarize the main evidence on the use of ultrasound and CEUS in the diagnosis of APN and its follow-up.

6.
J Vitreoretin Dis ; 8(5): 533-539, 2024.
Article in English | MEDLINE | ID: mdl-39351501

ABSTRACT

Introduction: To investigate whether there is visual function impairment in patients with posterior vitreous detachment (PVD) using the active-learning quantitative contrast sensitivity function test. Methods: In this cross-sectional study, contrast sensitivity was measured in eyes with PVD and eyes without PVD using the quantitative contrast sensitivity function algorithm on the Adaptive Sensory Technology platform. Outcomes included the area under the log contrast sensitivity function curve, contrast acuity, and contrast sensitivity thresholds at 1 to 18 cycles per degree (cpd). Snellen visual acuity (VA) was also measured. Mixed-effects multiple linear regression analyses were performed to evaluate the association between the presence of PVD and visual function, controlling for age and lens status. Results: The cohort comprised 232 healthy eyes of 205 participants; of these, 80 eyes of 69 patients had PVD. There was no significant association between VA and PVD presence. However, PVD was significantly associated with decreased contrast sensitivity thresholds at 1.5 cpd (ß, -0.058; P = .003) and 3 cpd (ß, -0.067; P = .004). Contrast sensitivity thresholds at lower (1 cpd) or higher (6, 12, 18 cpd) spatial frequencies did not significantly correlate with PVD presence. Even in the subgroup of symptomatic PVD eyes, VA was not significantly decreased, while quantitative contrast sensitivity function outcomes showed visual function deficits at low spatial frequencies (1.5 cpd and 3 cpd). Conclusions: Contrast sensitivity measured with the quantitative contrast sensitivity function test showed visual function deficits in eyes with PVD that would have been missed with VA testing alone. Incorporating this test in the retina clinic might offer a more comprehensive functional assessment of eyes with PVD, serving as an adjunct outcome metric in clinical decision-making.

7.
World J Gastrointest Surg ; 16(9): 2942-2952, 2024 Sep 27.
Article in English | MEDLINE | ID: mdl-39351558

ABSTRACT

BACKGROUND: Gastrointestinal stromal tumors (GISTs) vary widely in prognosis, and traditional pathological assessments often lack precision in risk stratification. Advanced imaging techniques, especially magnetic resonance imaging (MRI), offer potential improvements. This study investigates how MRI imagomics can enhance risk assessment and support personalized treatment for GIST patients. AIM: To assess the effectiveness of MRI imagomics in improving GIST risk stratification, addressing the limitations of traditional pathological assessments. METHODS: Analyzed clinical and MRI data from 132 GIST patients, categorizing them by tumor specifics and dividing into risk groups. Employed dimension reduction for optimal imagomics feature selection from diffusion-weighted imaging (DWI), T1-weighted imaging (T1WI), and contrast enhanced T1WI with fat saturation (CE-T1WI) fat suppress (fs) sequences. RESULTS: Age, lesion diameter, and mitotic figures significantly correlated with GIST risk, with DWI sequence features like sphericity and regional entropy showing high predictive accuracy. The combined T1WI and CE-T1WI fs model had the best predictive efficacy. In the test group, the DWI sequence model demonstrated an area under the curve (AUC) value of 0.960 with a sensitivity of 80.0% and a specificity of 100.0%. On the other hand, the combined performance of the T1WI and CE-T1WI fs models in the test group was the most robust, exhibiting an AUC value of 0.834, a sensitivity of 70.4%, and a specificity of 85.2%. CONCLUSION: MRI imagomics, particularly DWI and combined T1WI/CE-T1WI fs models, significantly enhance GIST risk stratification, supporting precise preoperative patient assessment and personalized treatment plans. The clinical implications are profound, enabling more accurate surgical strategy formulation and optimized treatment selection, thereby improving patient outcomes. Future research should focus on multicenter studies to validate these findings, integrate advanced imaging technologies like PET/MRI, and incorporate genetic factors to achieve a more comprehensive risk assessment.

8.
World J Radiol ; 16(9): 375-379, 2024 Sep 28.
Article in English | MEDLINE | ID: mdl-39355388

ABSTRACT

Contrast-induced acute kidney injury (CI-AKI) is a major concern in clinical practice, particularly among high-risk patients with preexisting renal and cardiovascular conditions. Although periprocedural hydration has long been the primary approach for CI-AKI prevention, recent advancements have led to the development of novel approaches such as RenalGuard and contrast removal systems. This editorial explores these emerging approaches and highlights their potential for enhancing CI-AKI prevention. By incorporating the latest evidence into clinical practice, health-care professionals can more effectively maintain renal function and improve outcomes for patients undergoing contrast-enhanced procedures.

9.
Rev Cardiovasc Med ; 25(9): 338, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39355575

ABSTRACT

Background: The high-sensitivity C-reactive protein to high-density lipoprotein cholesterol ratio (CHR) is a novel biomarker associated with coronary artery disease (CAD) risk. This study aimed to analyze the relationship between CHR and contrast-induced acute kidney injury (CI-AKI). Methods: This retrospective cross-sectional research included 10,917 individuals who underwent PCI. CI-AKI was diagnosed using the Kidney Disease: Improving Global Outcomes (KIDIGO) standard. Univariate and multivariable logistic regression analyses were conducted to examine the association between CHR and CI-AKI, followed by a receiver operating characteristic (ROC) curve of participants to assess the clinical diagnostic performance of CHR on CI-AKI. Results: A total of 1037 patients (9.50%) developed CI-AKI after PCI. The age of individuals averaged 64.1 ± 11.1 years old, with 2511 females (23.0%). A multivariate logistic regression study revealed that higher CHR levels were linked to higher CI-AKI incidence rates ([Q4 vs. Q1]: odds ratio (OR) = 1.89, 95% confidence interval (CI) [1.42 to 2.54], p < 0.001). A restricted cubic spline analysis revealed a linear association between CHR and CI-AKI. ROC analysis indicated that CHR was an excellent predictor of CI-AKI (area under ROC curve = 0.606, 95% CI [0.588 to 0.624]). Conclusions: A high CHR level is strongly associated with increased CI-AKI incidence, suggesting that CHR may be an independent risk factor for CI-AKI. Clinical Trial registration: NCT05050877. https://clinicaltrials.gov/study/NCT05050877?tab=results.

11.
Neurosurg Rev ; 47(1): 721, 2024 Oct 02.
Article in English | MEDLINE | ID: mdl-39356341

ABSTRACT

Assessing the extent of damage to the posterior limb of the internal capsule (PLIC) is important for early prediction of clinical outcomes in intracerebral hemorrhage (ICH) patients. Currently, using MRI to reconstruct the extent of damage to PLIC is not suitable for quick assessment of prognosis in emergency settings. We aimed to investigate whether the PLIC damage quantified by non-contrast computed tomography (NCCT) is associated with clinical outcomes after basal ganglia intracerebral hemorrhage (BG-ICH). This study retrospectively included 146 BG-ICH patients from the Department of Neurosurgery at the Second Affiliated Hospital of Chongqing Medical University. The damage to the PLIC was quantified using Tangency X measured by NCCT. The importance of features is determined using the Boruta algorithm and Least Absolute Shrinkage and Selection Operator (LASSO) regression. Multivariate logistic regression models were established to examine the impact of PLIC damage on outcomes. Restricted Cubic Splines (RCS) were used to explore potential nonlinear relationships, and Receiver Operating Characteristic (ROC) curves were used to compare the predictive performance of Tangency X with other scoring systems for 6-month neurological outcomes (poor outcomes [mRS: 3-6]). In the multivariate logistic regression adjusting for all covariates, Tangency X was independently associated with an increased risk of poor outcomes (OR = 1.32, 95% CI: 1.17-1.52) in BG-ICH patients. There is a nonlinear relationship between Tangency X and poor outcomes. Specifically, the risk of poor outcomes increases by 1.29 times (OR = 1.29, 95% CI: 1.09-1.67) for each additional 1 mm increase in Tangency X beyond 4 mm. We next observed that the AUC for Tangency X in predicting poor outcomes is 0.8511. The extent of PLIC damage measured by NCCT may represent a promising predictor of poor outcomes after BG-ICH.


Subject(s)
Basal Ganglia Hemorrhage , Internal Capsule , Tomography, X-Ray Computed , Humans , Female , Internal Capsule/diagnostic imaging , Male , Middle Aged , Basal Ganglia Hemorrhage/diagnostic imaging , Aged , Tomography, X-Ray Computed/methods , Retrospective Studies , Treatment Outcome , Adult , Prognosis
12.
Article in English | MEDLINE | ID: mdl-39356437

ABSTRACT

Iodinated contrast media (ICMs) used in X-ray imaging for medical diagnostics are released into wastewater and then encountered in river water at concentrations ranging from several dozen to hundreds of µg/L, and even thousands of µg/L in hospital effluents. ICMs are considered as emerging pollutants as their occurrence and impact on ecosystems and the environment are poorly documented. Even if they are considered inert for humans, aquatic organisms are continuously exposed to ICMs, and their potential deleterious effects are therefore questioned as we have recently demonstrated that they enter into organisms such as the zebra mussels. To answer this question, Dreissena polymorpha were exposed to two ICMs of different osmolality, diatrizoic acid and iohexol, at an environmental concentration (100 µg/L) for 21 days before a depuration phase of 4 days. The occurrence, fate, and impact of both ICMs in these organisms were studied using a metallomic approach. Thus, iodine as well as endogenous copper and zinc were quantified and analyzed in cytosolic extracts of digestive glands, gills, and gonads of mussels by size exclusion chromatography coupled to ICP MS. This work shows that a subcellular fractionation is necessary to distinguish variations in total element content. The cytosolic iodoprotein chromatographic pattern was consistent for the three organs and confirmed the presence of ICMs in cytosols. Additionally, this exploratory work tends to show a weak biological effect of ICMs with a substantial variation of the profile of Cu-binding proteins mostly in the gill cytosol and to a lesser extent, in the digestive gland cytosol.

13.
Neth Heart J ; 2024 Oct 02.
Article in English | MEDLINE | ID: mdl-39356452

ABSTRACT

Several risk prediction models exist to predict atherosclerotic cardiovascular disease in asymptomatic individuals, but systematic reviews have generally found these models to be of limited utility. The coronary artery calcium score (CACS) offers an improvement in risk prediction, yet its role remains contentious. Notably, its negative predictive value has a high ability to rule out clinically relevant atherosclerotic cardiovascular disease. Nonetheless, CACS 0 does not permanently reclassify to a lower cardiovascular risk and periodic reassessment every 5 to 10 years remains necessary. Conversely, elevated CACS (> 100 or > 75th percentile adjusted for age, sex and ethnicity) can reclassify intermediate-risk individuals to a high risk, benefiting from preventive medication. The forthcoming update to the Dutch cardiovascular risk management guideline intends to re-position CACS for cardiovascular risk assessment as such in asymptomatic individuals. Beyond CACS as a single number, several guidelines recommend coronary CT angiography (CCTA), which provides additional information about luminal stenosis and (high-risk) plaque composition, as the first choice of test in symptomatic patients and high-risk patients. Ongoing randomised studies will have to determine the value of atherosclerosis evaluation with CCTA for primary prevention in asymptomatic individuals.

14.
J Med Radiat Sci ; 2024 Sep 01.
Article in English | MEDLINE | ID: mdl-39217463

ABSTRACT

INTRODUCTION: Radiography students complete professional placements in various clinical settings and must adhere to distinct infection prevention and control (IPC) protocols. The aim of this study was to explore radiography students' training, knowledge, attitudes, and practice (KAP) relating to IPC in the use of contrast media injectors in computed tomography (CT). METHODS: An online survey study was undertaken with radiography students enrolled at two Australian universities. Survey questions related to contrast media training and KAP regarding IPC in CT. Data was summarised using descriptive statistics, with comparisons between experience in public and private practice. One free-text response question focused on non-adherence to IPC best practice, analysed using content analysis. RESULTS: In total, 40 students completed the survey (9% response rate). Reports of IPC and contrast media equipment training was high, with disposition for further training. Regarding IPC knowledge, 65% of students responded correctly to all 'knowledge' items (individual scores range: 60-100%). Low consensus was observed regarding whether gloves replace the need for hand hygiene and if CT contrast tubing poses risk to healthcare workers (85% each). Mean scores ranged from 41% to 100% regarding identification of sterile syringe and tubing components. Responses to the open-ended question were categorised into four themes: 'High non-adherence risk working conditions', 'attitudes and practice', 'knowledge', and 'prioritise good IPC practice'. CONCLUSIONS: Radiography students demonstrate varied comprehension of IPC regarding contrast media equipment, and results suggest need for collaborative efforts between academic institutions and clinical training sites to integrate IPC protocols into curricula and on-site training.

15.
Article in English | MEDLINE | ID: mdl-39219453

ABSTRACT

BACKGROUND: Patients with chronic kidney disease and CAD have been denied revascularization because of fear of precipitating acute renal failure from contrast exposure. Skepticism on whether Ultra-Low contrast percutaneous coronary intervention (PCI) or Zero contrast PCI (ULC/ZC PCI) can be safely performed has limited its adoption. METHODS: This observational registry enrolled 200 consecutive patients referred for elective PCI at a single center from June 2021 to December 2022. The study investigated whether the clinical outcomes of PCI performed with UL/ZC-PCI (n-48) were comparable to outcomes following standard PCI (n-152). RESULTS: Both groups were well matched in baseline and procedural characteristics. The groups had a highly statistical difference in the use of CV. Mean CV was 19.17 ± 7.29 cc in the ULC/ZC-group and 147.14 ± 73.55 cc in the control arm. The principal findings of the study were that the incidence of ontrast-induced acute kidney injury (AKI) was eightfold lower in patients receiving UL/ZC compared to the control group that received standard PCI. The incidence of all-cause mortality, myocardial infarction and major bleeding were similar in both groups. At 6 months, the decrement in renal function was lower in the group that received lower volumes of contrast. CONCLUSIONS: This single center observational registry demonstrated that UL-C/ZC-PCI is safe and effective in a broad spectrum of complex lesions. The skillsets needed to perform this are teachable, widely applicable and do not require a large upgrade of capital equipment. AKI rates and decrement in renal function at 6 months were both significantly lower in the UL-ZC group.

16.
J Belg Soc Radiol ; 108(1): 73, 2024.
Article in English | MEDLINE | ID: mdl-39219810

ABSTRACT

Teaching point: Aortoenteric fistula, a major complication of aortic surgery, can be identified with certainty on CT scan with opacification of the intestinal tract.

17.
J Diabetes Res ; 2024: 4905669, 2024.
Article in English | MEDLINE | ID: mdl-39219990

ABSTRACT

Background: Deposition of adipose tissue may have a promoting role in the development of diabetic complications. This study is aimed at investigating the relationship between adipose tissue thickness and risk of contrast-induced nephropathy (CIN) in patients with Type 2 diabetes mellitus (T2DM). Methods: A total of 603 T2DM patients undergoing percutaneous coronary angiography or angioplasty with suspicious or confirmed stable coronary artery disease were enrolled in this study. The thicknesses of perirenal fat (PRF), subcutaneous fat (SCF), intraperitoneal fat (IPF), and epicardial fat (ECF) were measured by color Doppler ultrasound, respectively. The association of various adipose tissues with CIN was analyzed. Results: Seventy-seven patients (12.8%) developed CIN in this cohort. Patients who developed CIN had significantly thicker PRF (13.7 ± 4.0 mm vs. 8.9 ± 3.6 mm, p < 0.001), slightly thicker IPF (p = 0.046), and similar thicknesses of SCF (p = 0.782) and ECF (p = 0.749) compared to those who did not develop CIN. Correlation analysis showed that only PRF was positively associated with postoperation maximal serum creatinine (sCr) (r = 0.18, p = 0.012), maximal absolute change in sCr (r = 0.33, p < 0.001), and maximal percentage of change in sCr (r = 0.36, p < 0.001). In receiver operating characteristic (ROC) analysis, the area under the curve (AUC) of PRF (0.809) for CIN was significantly higher than those of SCF (0.490), IPF (0.594), and ECF (0.512). Multivariate logistic regression analysis further confirmed that thickness of PRF, rather than other adipose tissues, was independently associated with the development of CIN after adjusted for confounding factors (odds ratio (OR) = 1.53, 95% CI: 1.38-1.71, p < 0.001). Conclusions: PRF is independently associated with the development of CIN in T2DM patients undergoing coronary catheterization.


Subject(s)
Contrast Media , Coronary Angiography , Diabetes Mellitus, Type 2 , Diabetic Nephropathies , Humans , Diabetes Mellitus, Type 2/complications , Female , Male , Contrast Media/adverse effects , Middle Aged , Aged , Coronary Angiography/adverse effects , Risk Factors , Coronary Artery Disease/diagnostic imaging , Adipose Tissue/diagnostic imaging , Adipose Tissue/pathology , Kidney Diseases/chemically induced , Intra-Abdominal Fat/diagnostic imaging , Cardiac Catheterization/adverse effects , Creatinine/blood
18.
Biomed Eng Lett ; 14(5): 1125-1135, 2024 Sep.
Article in English | MEDLINE | ID: mdl-39220033

ABSTRACT

Dual-mode optical imaging can simultaneously provide morphological and functional information. Furthermore, it can be integrated with projection mapping method to directly observe the images in the region of interest. This study was aimed to develop a dual-mode optical projection mapping system (DOPMS) that obtains laser speckle contrast image (LSCI) and subcutaneous vein image (SVI) and projects onto the region of interest, minimizing the spatial misalignment between the regions captured by the camera and projected by a projector. In in vitro and in vivo studies, LSCI and SVI were obtained and projected under single-mode illumination, where either the laser or light-emitting diode (LED) was activated, and under dual-mode illumination, where the laser and LED were activated simultaneously. In addition, fusion image (FI) of LSCI and SVI was implemented to selectively observe blood perfusion in the vein. DOPMS successfully obtained LSCI, SVI, and FI and projected them onto the identical region of interest, minimizing spatial misalignment. Single-mode illumination resulted in relatively clearer and noise-free images. Dual-mode illumination introduced speckle noise to SVI and FI but enabled real-time imaging by simultaneously employing LSCI, SVI, and FI. FI may be more effective for quasi-static evaluations before and after treatment under single-mode illumination and for real-time evaluation during treatment under dual-mode illumination owing to its faster image processing, albeit with a potential tradeoff in image quality.

19.
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 46(4): 575-580, 2024 Aug.
Article in Chinese | MEDLINE | ID: mdl-39223022

ABSTRACT

Hepatic sinusoidal obstruction syndrome (HSOS),a toxic liver injury,can lead to multiple organ failure in severe cases and is even fatal.Early diagnosis is of great significance for the selection of treatment regimens and prognosis.Currently,ultrasound,as the preferred diagnostic method for liver diseases,has been recommended in expert consensus and criteria for the diagnosis of HSOS.However,there are no definitive imaging diagnostic standards.This paper summarizes the sonographic features of ultrasound and new ultrasound technologies in HSOS research.Analyzing the characteristic sonographic images from gray-scale ultrasonography,Doppler ultrasonography,ultrasound elastography,and contrast-enhanced ultrasonography at different stages of the disease enables the establishment and refining of the corresponding imaging diagnostic standards and provides effective auxiliary examination methods for the early diagnosis and differential diagnosis of HSOS.


Subject(s)
Hepatic Veno-Occlusive Disease , Ultrasonography , Hepatic Veno-Occlusive Disease/diagnostic imaging , Humans , Ultrasonography/methods
20.
Article in English | MEDLINE | ID: mdl-39225035

ABSTRACT

PURPOSE: To assess the visual impact of Diffusion Optics Technology™ 0.2 DOT lenses (SightGlass Vision Inc.) designed for myopia control on primary gaze. DOT spectacle lenses contain light scattering elements that scatter light as it passes through the lens which, in turn, reduces retinal image contrast. METHODS: Fifty-one children (12.2 ± 1.3, range 10-14 years; 51% females) were randomly assigned to wear DOT spectacle (n = 27) or single vision lenses (n = 24) across six investigational sites in North America. Binocular high- and low-contrast distant visual acuities, near visual acuity, reading speed, contrast sensitivity, stereoacuity and glare were assessed in primary gaze after at least 3 years of wear, with the study 95% powered in all metrics to detect significant differences between the groups. RESULTS: Mean binocular distance high-contrast (-0.09 ± 0.02 vs. -0.08 ± 0.02 logMAR, p = 0.81), low-contrast (0.05 ± 0.02 vs. 0.07 ± 0.02 logMAR, p = 0.52) and near visual acuity with glare sources (-0.06 ± 0.03 vs. -0.09 ± 0.03 logMAR, p = 0.32) were similar for DOT and single vision lens wearers, respectively. Contrast sensitivity was similar between children wearing DOT or single vision lenses across 11 of the 16 spatial frequencies (p > 0.05). Mean stereopsis was similar (p = 0.30) with the DOT lenses (33.2 ± 12.5″) and single vision lenses (38.1 ± 14.2″). Functional reading speed metrics were similar in both study groups, as was the objectively measured head tilt during reading (p > 0.05). The mean halo radius was 0.56° ± 0.17° with the DOT lenses compared with 0.50° ± 0.12° with single vision lenses (p = 0.02), but the statistically significant difference was smaller than the non-inferiority bound of 0.4°. CONCLUSION: Diffusion optics technology lenses provide a clinically equivalent visual experience to a standard single vision lens.

SELECTION OF CITATIONS
SEARCH DETAIL