Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Environ Mol Mutagen ; 2024 Jul 16.
Article in English | MEDLINE | ID: mdl-39012003

ABSTRACT

The detection of N-nitrosamines in drug products has raised global regulatory interest in recent years due to the carcinogenic potential of some nitrosamines in animals and a need to identify a testing strategy has emerged. Ideally, methods used would allow for the use of quantitative analysis of dose-response data from in vivo genotoxicity assays to determine a compound-specific acceptable intake for novel nitrosamines without sufficient carcinogenicity data. In a previous study we compared the dose-response relationships of N-nitrosodiethylamine (NDEA) in three in vivo genotoxicity endpoints in rats. Here we report a comparison of NDEA's genotoxicity profile in mice. Big Blue® mice were administered NDEA at doses of 0.001, 0.01, 0.1, 1 and 3 mg/kg/day by oral gavage for 28 days followed by 3 days of expression. Statistically significant increases in the NDEA induced mutations were detected by both the transgenic rodent mutation assay (TGR) using the cII endpoint and by duplex sequencing in the liver but not bone marrow of mice. In addition, administration of NDEA for two consecutive days in male C57BL/6N mice caused elevated DNA damage levels in the liver as measured by % tail DNA in comet assay. The benchmark dose (BMD) analysis shows a BMDL50 of 0.03, 0.04 and 0.72 mg/kg/day for TGR, duplex sequencing and comet endpoints, respectively. Overall, this study demonstrated a similar genotoxicity profile of NDEA between mice and rats and provides a reference that can be used to compare the potential potency of other novel nitrosamines for the induction of gene mutations.

2.
Article in English | MEDLINE | ID: mdl-38821675

ABSTRACT

Currently, there is no test system, whether in vitro or in vivo, capable of examining all endpoints required for genotoxicity evaluation used in pre-clinical drug safety assessment. The objective of this study was to develop a model which could assess all the required endpoints and possesses robust human metabolic activity, that could be used in a streamlined, animal-free manner. Liver-on-chip (LOC) models have intrinsic human metabolic activity that mimics the in vivo environment, making it a preferred test system. For our assay, the LOC was assembled using primary human hepatocytes or HepaRG cells, in a MPS-T12 plate, maintained under microfluidic flow conditions using the PhysioMimix® Microphysiological System (MPS), and co-cultured with human lymphoblastoid (TK6) cells in transwells. This system allows for interaction between two compartments and for the analysis of three different genotoxic endpoints, i.e. DNA strand breaks (comet assay) in hepatocytes, chromosome loss or damage (micronucleus assay) and mutation (Duplex Sequencing) in TK6 cells. Both compartments were treated at 0, 24 and 45 h with two direct genotoxicants: methyl methanesulfonate (MMS) and ethyl methanesulfonate (EMS), and two genotoxicants requiring metabolic activation: benzo[a]pyrene (B[a]P) and cyclophosphamide (CP). Assessment of cytochrome activity, RNA expression, albumin, urea and lactate dehydrogenase production, demonstrated functional metabolic capacities. Genotoxicity responses were observed for all endpoints with MMS and EMS. Increases in the micronucleus and mutations (MF) frequencies were also observed with CP, and %Tail DNA with B[a]P, indicating the metabolic competency of the test system. CP did not exhibit an increase in the %Tail DNA, which is in line with in vivo data. However, B[a]P did not exhibit an increase in the % micronucleus and MF, which might require an optimization of the test system. In conclusion, this proof-of-principle experiment suggests that LOC-MPS technology is a promising tool for in vitro hazard identification genotoxicants.


Subject(s)
Hepatocytes , Micronucleus Tests , Mutagenicity Tests , Mutagens , Humans , Hepatocytes/drug effects , Hepatocytes/metabolism , Mutagens/toxicity , Micronucleus Tests/methods , Mutagenicity Tests/methods , Liver/drug effects , Liver/metabolism , Lab-On-A-Chip Devices , DNA Damage/drug effects , Comet Assay/methods , Cyclophosphamide/toxicity , Methyl Methanesulfonate/toxicity , Cell Line , Benzo(a)pyrene/toxicity , Coculture Techniques , Ethyl Methanesulfonate/toxicity , Mutation/drug effects
3.
bioRxiv ; 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38529488

ABSTRACT

The combination of ultra-long Oxford Nanopore (ONT) sequencing reads with long, accurate PacBio HiFi reads has enabled the completion of a human genome and spurred similar efforts to complete the genomes of many other species. However, this approach for complete, "telomere-to-telomere" genome assembly relies on multiple sequencing platforms, limiting its accessibility. ONT "Duplex" sequencing reads, where both strands of the DNA are read to improve quality, promise high per-base accuracy. To evaluate this new data type, we generated ONT Duplex data for three widely-studied genomes: human HG002, Solanum lycopersicum Heinz 1706 (tomato), and Zea mays B73 (maize). For the diploid, heterozygous HG002 genome, we also used "Pore-C" chromatin contact mapping to completely phase the haplotypes. We found the accuracy of Duplex data to be similar to HiFi sequencing, but with read lengths tens of kilobases longer, and the Pore-C data to be compatible with existing diploid assembly algorithms. This combination of read length and accuracy enables the construction of a high-quality initial assembly, which can then be further resolved using the ultra-long reads, and finally phased into chromosome-scale haplotypes with Pore-C. The resulting assemblies have a base accuracy exceeding 99.999% (Q50) and near-perfect continuity, with most chromosomes assembled as single contigs. We conclude that ONT sequencing is a viable alternative to HiFi sequencing for de novo genome assembly, and has the potential to provide a single-instrument solution for the reconstruction of complete genomes.

4.
Food Chem Toxicol ; 185: 114512, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38342231

ABSTRACT

Duplex sequencing (DS) is an error-corrected next-generation sequencing (NGS) method that can overcome notorious high error rate from the process of NGS and detect ultralow-frequency mutations. In this study, we evaluated the mutagenicity of aristolochic acid, a known genotoxic carcinogen, and methapyrilene, a known nongenotoxic carcinogen using DS. Four male Fisher 344 rats were treated with aristolochic acid, methapyrilene, or the vehicle control for 6 weeks, liver tissues were collected one day after the treatment, and the DNA was isolated for analysis. The mutation frequency for the aristolochic acid-treated group was significantly increased over the vehicle control (44-fold), whereas no significant difference in the mutation frequency was observed between the methapyrilene-treated and the control groups. The primary type of mutation induced by aristolochic acid was A:T > T:A transversion, which occurred frequently at ApT sites, whereas the major type of mutation in the control and methapyrilene-treated groups was G:C > A:T transition, which occurred frequently at CpG sites. These findings are consistent with previously published data obtained with other in vivo mutation assays. Thus, our results suggest that the DS mutation assay is a promising technology for assessing mutagenicity of chemicals in vivo.


Subject(s)
Aristolochic Acids , Methapyrilene , Rats , Animals , Male , Mutagens/toxicity , Aristolochic Acids/toxicity , Carcinogens/toxicity
5.
Article in English | WPRIM (Western Pacific) | ID: wpr-829025

ABSTRACT

Accurate detection of low frequency mutations from plasma cell-free DNA in blood using targeted next generation sequencing technology has shown promising benefits in clinical settings. Duplex sequencing technology is the most commonly used approach in liquid biopsies. Unique molecular identifiers are attached to each double-stranded DNA template, followed by production of low-error consensus sequences to detect low frequency variants. However, high sequencing costs have hindered application of this approach in clinical practice. Here, we have developed an improved duplex sequencing approach called SinoDuplex, which utilizes a pool of adapters containing pre-defined barcode sequences to generate far fewer barcode combinations than with random sequences, and implemented a novel computational analysis algorithm to generate duplex consensus sequences more precisely. SinoDuplex increased the output of duplex sequencing technology, making it more cost-effective. We evaluated our approach using reference standard samples and cell-free DNA samples from lung cancer patients. Our results showed that SinoDuplex has high sensitivity and specificity in detecting very low allele frequency mutations. The source code for SinoDuplex is freely available at https://github.com/SinOncology/sinoduplex.

SELECTION OF CITATIONS
SEARCH DETAIL