Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.516
Filter
1.
Sci Rep ; 14(1): 17904, 2024 08 02.
Article in English | MEDLINE | ID: mdl-39095411

ABSTRACT

Seismocardiographic (SCG) signals are chest wall vibrations induced by cardiac activity and are potentially useful for cardiac monitoring and diagnosis. SCG waveform is observed to vary with respiration, but the mechanism of these changes is poorly understood as alterations in autonomic tone, lung volume, heart location and intrathoracic pressure are all varying during the respiratory cycle. Understanding SCG variability and its sources may help reduce variability and increase SCG clinical utility. This study investigated SCG variability during breath holding (BH) at two different lung volumes (i.e., end inspiration and end expiration) and five airway pressures (i.e., 0, ± 2-4, and ± 15-20 cm H2O). Variability during normal breathing was also studied with and without grouping SCG beats into two clusters of similar waveform morphologies (performed using the K-medoid algorithm in an unsupervised machine learning fashion). The study included 15 healthy subjects (11 Females and 4 males, Age: 21 ± 2 y) where SCG, ECG, and spirometry were simultaneously acquired. SCG waveform variability was calculated at each experimental state (i.e., lung volume and airway pressure). Results showed that breath holding was more effective in reducing the intra-state variability of SCG than clustering normal breathing data. For the BH states, the intra-state variability increased as the airway pressure deviated from zero. The subaudible-to-audible energy ratio of the BH states increased as the airway pressure decreased below zero which may be related to the effect of the intrathoracic pressure on cardiac afterload and blood ejection. When combining the BH waveforms at end inspiration and end expiration states (at the same airway pressures) into one group, the intra-state variability increased, which suggests that the lung volume and associated change in heart location were a significant source of variability. The linear trend between airway pressure and waveform changes was found to be statistically significant for BH at end expiration. To confirm these findings, more studies are needed with a larger number of airway pressure levels and larger number of subjects.


Subject(s)
Breath Holding , Humans , Male , Female , Young Adult , Lung/physiology , Respiration , Electrocardiography , Adult , Lung Volume Measurements , Spirometry/methods , Algorithms
2.
Undersea Hyperb Med ; 51(2): 173-184, 2024.
Article in English | MEDLINE | ID: mdl-38985153

ABSTRACT

Objective: This study aimed to systematically analyze the existing literature and conduct a meta-analysis on the acute effects of apnea on the hematological response by assessing changes in hemoglobin (Hb) concentration and hematocrit (Hct) values. Methods: Searches in Pubmed, The Cochrane Library, and Web of Science were carried out for studies in which the main intervention was voluntary hypoventilation, and Hb and Hct values were measured. Risk of bias and quality assessments were performed. Results: Nine studies with data from 160 participants were included, involving both subjects experienced in breath-hold sports and physically active subjects unrelated to breath-holding activities. The GRADE scale showed a "high" confidence for Hb concentration, with a mean absolute effect of 0.57 g/dL over control interventions. "Moderate" confidence appeared for Hct, where the mean absolute effect was 2.45% higher over control interventions. Hb concentration increased to a greater extent in the apnea group compared to the control group (MD = 0.57 g/dL [95% CI 0.28, 0.86], Z = 3.81, p = 0.0001) as occurred with Hct (MD = 2.45% [95% CI 0.98, 3.93], Z = 3.26, p = 0.001). Conclusions: Apnea bouts lead to a significant increase in the concentration of Hb and Hct with a high and moderate quality of evidence, respectively. Further trials on apnea and its application to different settings are needed.


Subject(s)
Hemoglobins , Humans , Apnea/blood , Apnea/etiology , Breath Holding , Hematocrit , Hemoglobins/analysis
3.
Undersea Hyperb Med ; 51(2): 189-196, 2024.
Article in English | MEDLINE | ID: mdl-38985155

ABSTRACT

Hypoxia, centralization of blood in pulmonary vessels, and increased cardiac output during physical exertion are the pathogenetic pathways of acute pulmonary edema observed during exposure to extraordinary environments. This study aimed to evaluate the effects of breath-hold diving at altitude, which exposes simultaneously to several of the stimuli mentioned above. To this aim, 11 healthy male experienced divers (age 18-52y) were evaluated (by Doppler echocardiography, lung echography to evaluate ultrasound lung B-lines (BL), hemoglobin saturation, arterial blood pressure, fractional NO (Nitrous Oxide) exhalation in basal condition (altitude 300m asl), at altitude (2507m asl) and after breath-hold diving at altitude. A significant increase in E/e' ratio (a Doppler-echocardiographic index of left atrial pressure) was observed at altitude, with no further change after the diving session. The number of BL significantly increased after diving at altitude as compared to basal conditions. Finally, fractional exhaled nitrous oxide was significantly reduced by altitude; no further change was observed after diving. Our results suggest that exposure to hypoxia may increase left ventricular filling pressure and, in turn, pulmonary capillary pressure. Breath-hold diving at altitude may contribute to interstitial edema (as evaluated by BL score), possibly because of physical efforts made during a diving session. The reduction of exhaled nitrous oxide at altitude confirms previous reports of nitrous oxide reduction after repeated exposure to hypoxic stimuli. This finding should be further investigated since reduced nitrous oxide production in hypoxic conditions has been reported in subjects prone to high-altitude pulmonary edema.


Subject(s)
Altitude , Breath Holding , Diving , Echocardiography, Doppler , Hypoxia , Lung , Humans , Male , Diving/physiology , Diving/adverse effects , Adult , Young Adult , Hypoxia/physiopathology , Middle Aged , Adolescent , Lung/physiopathology , Lung/diagnostic imaging , Lung/blood supply , Pulmonary Edema/etiology , Pulmonary Edema/physiopathology , Pulmonary Edema/diagnostic imaging , Arterial Pressure/physiology , Oxygen Saturation/physiology , Nitric Oxide/metabolism , Blood Pressure/physiology , Hemoglobins/analysis
4.
Radiat Prot Dosimetry ; 200(13): 1274-1293, 2024 Aug 09.
Article in English | MEDLINE | ID: mdl-39003236

ABSTRACT

The verification and use of the best treatment approach using 3D conformal radiation therapy (3DCRT), intensity modulated radiation therapy (IMRT) and Rapid Arc methods for left breast radiation with dosimetric and radiobiological characteristics. The use of custom-built Python software for the estimation and comparison of volume, mean dose, maximum dose, monitor units and normal tissue integral dose along with radiobiological parameters such as NTCP, tumor control probability, equivalent uniform dose and LKB's effective volume from 3DCRT, IMRT and Rapid Arc planning with deep inspiration with breath holding (DIBH) and free breadth (FB) techniques. Volume growth of three-fourth in DIBH compared with FB causes a decrease in cardiac doses and complications because the left lung expands, pulling the heart away from the chest wall and the treatment area. A tiny area of the left lung was exposed during treatment, which reduced the mean dose. There was little difference in the treatment approaches because the spinal cord was immobile in both techniques. Rapid Arc is the unmatched modality for left-sided breast irradiation with significant patient breath-hold, as shown by the comparison of dosimetric and radiobiological parameters from treatment techniques with a deep inspiration breath-hold approach.


Subject(s)
Breath Holding , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Unilateral Breast Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Organs at Risk/radiation effects , Radiometry/methods
5.
Eur J Radiol ; 177: 111549, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38850723

ABSTRACT

OBJECTIVES: To investigate PET/CT registration and quantification accuracy of thoracic lesions of a single 30-second deep-inspiration breath-hold (DIBH) technique with a total-body PET (TB-PET) scanner, and compared with free-breathing (FB) PET/CT. METHODS: 137 of the 145 prospectively enrolled patients finished a routine FB-300 s PET/CT exam and a 30-second DIBH TB-PET with chest to pelvis low dose CT. The total-body FB-300 s, FB-30 s, and DIBH-30 s PET images were reconstructed. Quantitative assessment (SUVmax and SUVmean of lung and other organs), PET/CT registration assessment and lesion analysis (SUVmax, SUVpeak, SUVmean and tumor-background ratio) were compared with Wilcoxon signed-rank tests. RESULTS: The SUVmax and SUVmean of the lung with DIBH-30 s were significantly lower than those with FB. The distances of the liver dome between PET and CT were significantly smaller with DIBH-30 s than with FB. 195 assessable lesions in 106 patients were included, and the detection sensitivity was 97.9 % and 99.0 % in FB-300 s, and DIBH-30 s, respectively. For both small co-identified lesions (n = 86) and larger co-identified lesions with a diameter ≥ 1 cm (n = 91), the lesion SUVs were significantly greater with DIBH-30 s than with FB-300 s. Regarding lesion location, the differences of the SUVs for the lesions in the lower thorax area (n = 97, p < 0.001) were significant between DIBH-30 s and FB-300 s, while these differences were not statistically significant in the upper thorax (n = 80, p > 0.05). The lesion tumor-to-surrounding-background ratio (TsBR) was significantly increased, both in the upper and lower thorax. CONCLUSION: The TB DIBH PET/CT technique is feasible in clinical practice. It reduces the background lung uptake and achieves better registration and lesion quantification, especially in the lower thorax.


Subject(s)
Breath Holding , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Radiopharmaceuticals , Sensitivity and Specificity , Whole Body Imaging , Humans , Positron Emission Tomography Computed Tomography/methods , Male , Female , Middle Aged , Aged , Whole Body Imaging/methods , Adult , Prospective Studies , Aged, 80 and over , Reproducibility of Results , Thoracic Neoplasms/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Inhalation
6.
Lakartidningen ; 1212024 Jun 05.
Article in Swedish | MEDLINE | ID: mdl-38836364

ABSTRACT

Witnessing breath-holding spells (BHS) can be distressing and patients with BHS disproportionately consume a substantial amount of health care resources. Common among preschool children, BHS follow a distinct sequence of events. A comprehensive patient history is the primary diagnostic tool. BHS lacked standardized diagnostic criteria and guidelines until our recent Acta Paediatrica publication. Studying 519 BHS cases in Skåne (years 2004-2018), we found overuse of electrocardiograms (ECGs) and electroencephalograms (EEGs), and underuse of blood tests for treatable iron deficiency and anemia, both known BHS contributors. Building upon our cohort analysis, we refined the definition of BHS and introduced a clinical management algorithm. Simulations showed reduced EEG and ECG use and an increase in blood tests. Our guideline not only streamlines diagnostic processes, but also optimizes the allocation of healthcare resources for more effective and targeted interventions.


Subject(s)
Algorithms , Breath Holding , Electrocardiography , Practice Guidelines as Topic , Humans , Child, Preschool , Electroencephalography , Infant , Anemia, Iron-Deficiency/diagnosis , Anemia, Iron-Deficiency/therapy , Child
7.
Curr Oncol ; 31(6): 3189-3198, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38920725

ABSTRACT

Women with left-sided breast cancer receiving adjuvant radiotherapy have increased incidence of cardiac mortality due to ischemic heart disease; to date, no threshold dose for late cardiac/pulmonary morbidity or mortality has been established. We investigated the likelihood of cardiac death and radiation pneumonitis in women with left-sided breast cancer who received comprehensive lymph node irradiation. The differences in dosimetric parameters between free-breathing (FB) and deep inspiration breath hold (DIBH) techniques were also addressed. Based on NTCP calculations, the probability of cardiac death was significantly reduced with the DIBH compared to the FB technique (p < 0.001). The risk of radiation pneumonitis was not clinically significant. There was no difference in coverage between FB and DIBH plans. Doses to healthy structures were significantly lower in DIBH plan than in FB plan for V20, V30, and ipsilateral total lung volume. Inspiratory gating reduces the dose absorbed by the heart without compromising the target range, thus reducing the likelihood of cardiac death.


Subject(s)
Unilateral Breast Neoplasms , Humans , Female , Unilateral Breast Neoplasms/radiotherapy , Middle Aged , Aged , Lymphatic Irradiation/methods , Radiotherapy Dosage , Radiotherapy, Adjuvant/methods , Adult , Breath Holding , Radiotherapy Planning, Computer-Assisted/methods , Lymph Nodes/pathology , Lymph Nodes/radiation effects
8.
Biomed Phys Eng Express ; 10(4)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38861951

ABSTRACT

Objective.We aim to: (1) quantify the benefits of lung sparing using non-adaptive magnetic resonance guided stereotactic body radiotherapy (MRgSBRT) with advanced motion management for peripheral lung cancers compared to conventional x-ray guided SBRT (ConvSBRT); (2) establish a practical decision-making guidance metric to assist a clinician in selecting the appropriate treatment modality.Approach.Eleven patients with peripheral lung cancer who underwent breath-hold, gated MRgSBRT on an MR-guided linear accelerator (MR linac) were studied. Four-dimensional computed tomography (4DCT)-based retrospective planning using an internal target volume (ITV) was performed to simulate ConvSBRT, which were evaluated against the original MRgSBRT plans. Metrics analyzed included planning target volume (PTV) coverage, various lung metrics and the generalized equivalent unform dose (gEUD). A dosimetric predictor for achievable lung metrics was derived to assist future patient triage across modalities.Main results.PTV coverage was high (median V100% > 98%) and comparable for both modalities. MRgSBRT had significantly lower lung doses as measured by V20 (median 3.2% versus 4.2%), mean lung dose (median 3.3 Gy versus 3.8 Gy) and gEUD. Breath-hold, gated MRgSBRT resulted in an average reduction of 47% in PTV volume and an average increase of 19% in lung volume. Strong correlation existed between lung metrics and the ratio of PTV to lung volumes (RPTV/Lungs) for both modalities, indicating that RPTV/Lungsmay serve as a good predictor for achievable lung metrics without the need for pre-planning. A threshold value of RPTV/Lungs< 0.035 is suggested to achieve V20 < 10% using ConvSBRT. MRgSBRT should otherwise be considered if the threshold cannot be met.Significance.The benefits of lung sparing using MRgSBRT were quantified for peripheral lung tumors; RPTV/Lungswas found to be an effective predictor for achievable lung metrics across modalities. RPTV/Lungscan assist a clinician in selecting the appropriate modality without the need for labor-intensive pre-planning, which has significant practical benefit for a busy clinic.


Subject(s)
Four-Dimensional Computed Tomography , Lung Neoplasms , Lung , Magnetic Resonance Imaging , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiosurgery/methods , Lung Neoplasms/radiotherapy , Lung Neoplasms/diagnostic imaging , Radiotherapy Planning, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Lung/diagnostic imaging , Retrospective Studies , Four-Dimensional Computed Tomography/methods , Male , Female , Radiotherapy, Image-Guided/methods , Breath Holding , Aged , Middle Aged , Organ Sparing Treatments/methods , Organs at Risk
9.
J Appl Clin Med Phys ; 25(8): e14414, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38803045

ABSTRACT

PURPOSE: To evaluate the intra-fractional tumor motion in lung stereotactic body radiotherapy (SBRT) with deep inspiration breath-hold (DIBH), and to investigate the adequacy of the current planning target volume (PTV) margins. METHODS: Twenty-eight lung SBRT patients with DIBH were selected in this study. Among the lesions, twenty-three were at right or left lower lobe, two at right middle lobe, and three at right or left upper lobe. Post-treatment gated cone-beam computed tomography (CBCT) was acquired to quantify the intra-fractional tumor shift at each treatment. These obtained shifts were then used to calculate the required PTV margin, which was compared with the current applied margin of 5 mm margin in anterior-posterior (AP) and right-left (RL) directions and 8 mm in superior-inferior (SI) direction. The beam delivery time was prolonged with DIBH. The actual beam delivery time with DIBH (Tbeam_DIBH) was compared with the beam delivery time without DIBH (Tbeam_wo_DIBH) for the corresponding SBRT plan. RESULTS: A total of 113 treatments were analyzed. At six treatments (5.3%), the shifts exceeded the tolerance defined by the current PTV margin. The average shifts were 0.0 ± 1.9 mm, 0.1±1.5 mm, and -0.5 ± 3.7 mm in AP, RL, and SI directions, respectively. The required PTV margins were determined to be 4.5, 3.9, and 7.4 mm in AP, RL, and SI directions, respectively. The average Tbeam_wo_DIBH and Tbeam_DIBH were 2.4 ± 0.4 min and 3.6 ± 1.5 min, respectively. The average treatment slot for lung SBRT with DIBH was 25.3 ± 7.9 min. CONCLUSION: Intra-fractional tumor motion is the predominant source of treatment uncertainties in CBCT-guided lung SBRT with DIBH. The required PTV margin should be determined based on data specific to each institute, considering different techniques and populations. Our data indicate that our current applied PTV margin is adequate, and it is possible to reduce further in the RL direction. The time increase of Tbeam_DIBH, relative to the treatment slot, is not clinically significant.


Subject(s)
Breath Holding , Cone-Beam Computed Tomography , Lung Neoplasms , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Lung Neoplasms/radiotherapy , Lung Neoplasms/surgery , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Radiotherapy Planning, Computer-Assisted/methods , Radiosurgery/methods , Cone-Beam Computed Tomography/methods , Radiotherapy, Intensity-Modulated/methods , Male , Aged , Female , Middle Aged , Organs at Risk/radiation effects , Movement , Aged, 80 and over , Dose Fractionation, Radiation , Prognosis , Inhalation
10.
PLoS One ; 19(5): e0296696, 2024.
Article in English | MEDLINE | ID: mdl-38722966

ABSTRACT

BACKGROUND: With recent advances in magnetic resonance imaging (MRI) technology, the practical role of lung MRI is expanding despite the inherent challenges of the thorax. The purpose of our study was to evaluate the current status of the concurrent dephasing and excitation (CODE) ultrashort echo-time sequence and the T1-weighted volumetric interpolated breath-hold examination (VIBE) sequence in the evaluation of thoracic disease by comparing it with the gold standard computed tomography (CT). METHODS: Twenty-four patients with lung cancer and mediastinal masses underwent both CT and MRI including T1-weighted VIBE and CODE. For CODE images, data were acquired in free breathing and end-expiratory images were reconstructed using retrospective respiratory gating. All images were evaluated through qualitative and quantitative approaches regarding various anatomical structures and lesions (nodule, mediastinal mass, emphysema, reticulation, honeycombing, bronchiectasis, pleural plaque and lymphadenopathy) inside the thorax in terms of diagnostic performance in making specific decisions. RESULTS: Depiction of the lung parenchyma, mediastinal and pleural lesion was not significant different among the three modalities (p > 0.05). Intra-tumoral and peritumoral features of lung nodules were not significant different in the CT, VIBE or CODE images (p > 0.05). However, VIBE and CODE had significantly lower image quality and poorer depiction of airway, great vessels, and emphysema compared to CT (p < 0.05). Image quality of central airways and depiction of bronchi were significantly better in CODE than in VIBE (p < 0.001 and p = 0.005). In contrast, the depiction of the vasculature was better for VIBE than CODE images (p = 0.003). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were significant greater in VIBE than CODE except for SNRlung and SNRnodule (p < 0.05). CONCLUSIONS: Our study showed the potential of CODE and VIBE sequences in the evaluation of localized thoracic abnormalities including solid pulmonary nodules.


Subject(s)
Lung Neoplasms , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Female , Male , Middle Aged , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Aged , Tomography, X-Ray Computed/methods , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods , Adult , Lung/diagnostic imaging , Lung/pathology , Retrospective Studies , Breath Holding
11.
Curr Sports Med Rep ; 23(5): 199-206, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38709946

ABSTRACT

ABSTRACT: Breath-hold divers, also known as freedivers, are at risk of specific injuries that are unique from those of surface swimmers and compressed air divers. Using peer-reviewed scientific research and expert opinion, we created a guide for medical providers managing breath-hold diving injuries in the field. Hypoxia induced by prolonged apnea and increased oxygen uptake can result in an impaired mental state that can manifest as involuntary movements or full loss of consciousness. Negative pressure barotrauma secondary to airspace collapse can lead to edema and/or hemorrhage. Positive pressure barotrauma secondary to overexpansion of airspaces can result in gas embolism or air entry into tissues and organs. Inert gas loading into tissues from prolonged deep dives or repetitive shallow dives with short surface intervals can lead to decompression sickness. Inert gas narcosis at depth is commonly described as an altered state similar to that experienced by compressed air divers. Asymptomatic cardiac arrhythmias are common during apnea, normally reversing shortly after normal ventilation resumes. The methods of glossopharyngeal breathing (insufflation and exsufflation) can add to the risk of pulmonary overinflation barotrauma or loss of consciousness from decreased cardiac preload. This guide also includes information for medical providers who are tasked with providing medical support at an organized breath-hold diving event with a list of suggested equipment to facilitate diagnosis and treatment outside of the hospital setting.


Subject(s)
Barotrauma , Breath Holding , Decompression Sickness , Diving , Humans , Diving/injuries , Diving/adverse effects , Barotrauma/etiology , Barotrauma/diagnosis , Decompression Sickness/therapy , Decompression Sickness/etiology , Decompression Sickness/diagnosis , Hypoxia/etiology , Inert Gas Narcosis/etiology , Inert Gas Narcosis/diagnosis
12.
Magn Reson Med ; 92(3): 1138-1148, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38730565

ABSTRACT

PURPOSE: To develop a highly accelerated multi-echo spin-echo method, TEMPURA, for reducing the acquisition time and/or increasing spatial resolution for kidney T2 mapping. METHODS: TEMPURA merges several adjacent echoes into one k-space by either combining independent echoes or sharing one echo between k-spaces. The combined k-space is reconstructed based on compressed sensing theory. Reduced flip angles are used for the refocusing pulses, and the extended phase graph algorithm is used to correct the effects of indirect echoes. Two sequences were developed: a fast breath-hold sequence; and a high-resolution sequence. The performance was evaluated prospectively on a phantom, 16 healthy subjects, and two patients with different types of renal tumors. RESULTS: The fast TEMPURA method reduced the acquisition time from 3-5 min to one breath-hold (18 s). Phantom measurements showed that fast TEMPURA had a mean absolute percentage error (MAPE) of 8.2%, which was comparable to a standardized respiratory-triggered sequence (7.4%), but much lower than a sequence accelerated by purely k-t undersampling (21.8%). High-resolution TEMPURA reduced the in-plane voxel size from 3 × 3 to 1 × 1 mm2, resulting in improved visualization of the detailed anatomical structure. In vivo T2 measurements demonstrated good agreement (fast: MAPE = 1.3%-2.5%; high-resolution: MAPE = 2.8%-3.3%) and high correlation coefficients (fast: R = 0.85-0.98; high-resolution: 0.82-0.96) with the standardized method, outperforming k-t undersampling alone (MAPE = 3.3-4.5%, R = 0.57-0.59). CONCLUSION: TEMPURA provides fast and high-resolution renal T2 measurements. It has the potential to improve clinical throughput and delineate intratumoral heterogeneity and tissue habitats at unprecedented spatial resolution.


Subject(s)
Algorithms , Kidney Neoplasms , Kidney , Phantoms, Imaging , Humans , Kidney Neoplasms/diagnostic imaging , Kidney/diagnostic imaging , Magnetic Resonance Imaging/methods , Female , Adult , Male , Image Interpretation, Computer-Assisted/methods , Reproducibility of Results , Middle Aged , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Breath Holding
13.
Magn Reson Imaging ; 111: 138-147, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38729225

ABSTRACT

OBJECTIVES: To explore the potential and performance of quantitative and semi-quantitative parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) based on compressed sensing volumetric interpolated breath-hold (CS-VIBE) examination in the differential diagnosis of thyroid nodules. MATERIALS AND METHODS: A total of 208 patients with 259 thyroid nodules scheduled for surgery operation were prospectively recruited. All participants underwent routine and DCE-MRI. DCE-MRI quantitative parameters [Ktrans, Kep, Ve], semi-quantitative parameters [wash-in, wash-out, time to peak (TTP), arrival time (AT), peak enhancement intensity (PEI), and initial area under curve in 60 s (iAUC)] and time-intensity curve (TIC) types were analyzed. Differential diagnostic performances were assessed using area under the receiver operating characteristic curve (AUC) and compared with the Delong test. RESULTS: Ktrans, Kep, Ve, wash-in, wash-out, PEI and iAUC were statistically significantly different between malignant and benign nodules (P < 0.001). Among these parameters, ROC analysis revealed that Ktrans showed the highest diagnostic performance in the differentiation of benign and malignant nodules, followed by wash-in. ROC analysis also revealed that Ktrans achieved the best diagnostic performance for distinguishing papillary thyroid carcinoma (PTC) from non-PTC, follicular adenoma (FA) from non-FA, nodular goiter (NG) from non-NG, with AUC values of 0.854, 0.895 and 0.609, respectively. Type III curve is frequently observed in benign thyroid nodules, accounting for 77.4% (82/106). While malignant nodules are more common in type II, accounting for 57.5% (88/153). CONCLUSION: Thyroid examination using CS-VIBE based DCE-MRI is a feasible, non-invasive method to identify benign and malignant thyroid nodules and pathological types.


Subject(s)
Breath Holding , Contrast Media , Feasibility Studies , Magnetic Resonance Imaging , Thyroid Nodule , Humans , Male , Female , Thyroid Nodule/diagnostic imaging , Middle Aged , Adult , Magnetic Resonance Imaging/methods , Diagnosis, Differential , Aged , Prospective Studies , ROC Curve , Thyroid Gland/diagnostic imaging , Thyroid Gland/pathology , Image Interpretation, Computer-Assisted/methods , Young Adult , Reproducibility of Results , Image Enhancement/methods , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Sensitivity and Specificity
14.
Pediatr Neurol ; 156: 53-58, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38733854

ABSTRACT

BACKGROUND: Breath-holding spells are a benign condition primarily seen in 3% to 5% of healthy children aged between six months and five years. Although no specific treatment is recommended due to its benign nature, iron and piracetam are used in severe or recurrent cases. We planned to compare the heart rate variability (HRV) before and after treatment with 24-hour Holter monitoring in patients receiving iron and piracetam treatment and investigate the treatment's effectiveness. METHODS: Twenty-five patients who applied to the outpatient clinic between 2013 and 2015 due to breath-holding spells were included in the study. The patients who received piracetam and iron therapy and underwent 24-hour rhythm Holter monitoring were evaluated retrospectively. RESULTS: Fourteen (56%) of these patients were evaluated as having cyanotic-type and 11 (44%) patients were assessed as having pale-type breath-holding spells. A significant difference was found only between hourly peak heart rate and total power in the group receiving iron treatment. Significant differences were also found among the minimum heart rate, mean heart rate, the standard deviation of RR intervals, the mean square root of the sum of the squares of their difference between adjacent RR intervals, spectpow, and low frequency before and after the treatment in the patients who started piracetam treatment (P < 0.05). CONCLUSIONS: Our study is critical as it is the first to investigate the effects of treatment options on various HRV in patients with breath-holding spells. There were statistically significant changes in HRV parameters in patients receiving piracetam, and the number of attacks decreased significantly. Piracetam treatment contributes positively to the breath-holding spell with regard to efficacy and HRV, therefore it can be used to treat breath-holding spells.


Subject(s)
Breath Holding , Heart Rate , Piracetam , Humans , Heart Rate/drug effects , Heart Rate/physiology , Breath Holding/drug effects , Male , Female , Child, Preschool , Retrospective Studies , Infant , Piracetam/pharmacology , Piracetam/administration & dosage , Piracetam/therapeutic use , Electrocardiography, Ambulatory/drug effects , Treatment Outcome , Iron/administration & dosage , Iron/pharmacology
15.
J Cancer Res Ther ; 20(3): 863-868, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38623966

ABSTRACT

PURPOSE: To investigate the effects of different dose rates (DRs) in continuous and interrupted irradiation on in-vitro survival of the MCF-7 cell line, towards finding possible radiobiological effects of breath-hold techniques in breast radiotherapy (RT), in which intra-fractional beam interruptions and delivery prolongation can occur. MATERIALS AND METHODS: MCF-7 cells were irradiated continuously or with regular interruptions using 6 MV x-rays at different accelerator DRs (50-400 cGy/min) to deliver a 2 Gy dose. The interrupted irradiation was delivered in a 10 s on, 10 s off manner. Then, cell survival and viability were studied using colony and MTT assays, respectively. RESULTS: Survival and viability with continuous and interrupted irradiation were similar ( P > 0.5). A significant increase in survival at 50, 100, and 400 cGy/min compared to 200 and 300 cGy/min was observed, also a significant decreasing and then increasing trend from 50 to 200 cGy/min and 200 to 400 cGy/min, respectively ( P < 0.04). Relative to 200 cGy/min, the survival fractions at 50, 100, 300, and 400 cGy/min were 1.24, 1.23, 1.05, and 1.20 times greater, respectively. Cell viability did not show significant differences between the DRs, despite following the same trend as cell survival. CONCLUSION: Our results suggest that for continuous irradiation of in-vitro MCF-7 cells, with increasing DR within the 50-400 cGy/min range, sensitivity increases and then decreases (inverse effect), also that up to doubling of treatment time in breath-hold techniques does not affect in-vitro radiobiological efficacy with 200-400 cGy/min accelerator DRs. Further confirmatory studies are required.


Subject(s)
Breast Neoplasms , Breath Holding , Cell Survival , Dose Fractionation, Radiation , Humans , Breast Neoplasms/radiotherapy , Breast Neoplasms/pathology , Cell Survival/radiation effects , MCF-7 Cells , Female , Dose-Response Relationship, Radiation , Radiobiology/methods , Radiotherapy Dosage
16.
Abdom Radiol (NY) ; 49(8): 2574-2584, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38662208

ABSTRACT

PURPOSE: The purpose of our study is to investigate image quality, efficiency, and diagnostic performance of a deep learning-accelerated single-shot breath-hold (DLSB) against BLADE for T2-weighted MR imaging (T2WI) for gastric cancer (GC). METHODS: 112 patients with GCs undergoing gastric MRI were prospectively enrolled between Aug 2022 and Dec 2022. Axial DLSB-T2WI and BLADE-T2WI of stomach were scanned with same spatial resolution. Three radiologists independently evaluated the image qualities using a 5-scale Likert scales (IQS) in terms of lesion delineation, gastric wall boundary conspicuity, and overall image quality. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated in measurable lesions. T staging was conducted based on the results of both sequences for GC patients with gastrectomy. Pairwise comparisons between DLSB-T2WI and BLADE-T2WI were performed using the Wilcoxon signed-rank test, paired t-test, and chi-squared test. Kendall's W, Fleiss' Kappa, and intraclass correlation coefficient values were used to determine inter-reader reliability. RESULTS: Against BLADE, DLSB reduced total acquisition time of T2WI from 495 min (mean 4:42 per patient) to 33.6 min (18 s per patient), with better overall image quality that produced 9.43-fold, 8.00-fold, and 18.31-fold IQS upgrading against BALDE, respectively, in three readers. In 69 measurable lesions, DLSB-T2WI had higher mean SNR and higher CNR than BLADE-T2WI. Among 71 patients with gastrectomy, DLSB-T2WI resulted in comparable accuracy to BLADE-T2WI in staging GCs (P > 0.05). CONCLUSIONS: DLSB-T2WI demonstrated shorter acquisition time, better image quality, and comparable staging accuracy, which could be an alternative to BLADE-T2WI for gastric cancer imaging.


Subject(s)
Deep Learning , Magnetic Resonance Imaging , Neoplasm Staging , Stomach Neoplasms , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/pathology , Humans , Female , Male , Middle Aged , Prospective Studies , Aged , Magnetic Resonance Imaging/methods , Adult , Reproducibility of Results , Image Interpretation, Computer-Assisted/methods , Breath Holding , Aged, 80 and over , Signal-To-Noise Ratio
17.
Br J Radiol ; 97(1158): 1162-1168, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38648776

ABSTRACT

OBJECTIVES: A portable respiratory training system with a gyroscope sensor (gyroscope respiratory training system [GRTS]) was developed and the feasibility of respiratory training was evaluated. METHODS: Simulated respiratory waveforms from a respiratory motion phantom and actual respirator waveforms from volunteers were acquired using the GRTS and Respiratory Gating for Scanners system (RGSC). Respiratory training was evaluated by comparing the stability and reproducibility of respiratory waveforms from patients undergoing expiratory breath-hold radiation therapy, with and without the GRTS. The stability and reproducibility of respiratory waveforms were assessed by root mean square error and gold marker placement-based success rate of expiratory breath-hold, respectively. RESULTS: The absolute mean difference for sinusoidal waveforms between the GRTS and RGSC was 2.0%. Among volunteers, the mean percentages of errors within ±15% of the respiratory waveforms acquired by the GRTS and RGSC were 96.1% for free breathing and 88.2% for expiratory breath-hold. The mean root mean square error and success rate of expiratory breath-hold (standard deviation) with and without the GRTS were 0.65 (0.24) and 0.88 (0.89) cm and 91.0% (6.9) and 89.1% (11.6), respectively. CONCLUSIONS: Respiratory waveforms acquired by the GRTS exhibit good agreement with waveforms acquired by the RGSC. Respiratory training with the GRTS reduces inter-patient variability in respiratory waveforms, thereby improving the success of expiratory breath-hold radiation therapy. ADVANCES IN KNOWLEDGE: A respiratory training system with a gyroscope sensor is inexpensive and portable, making it ideal for respiratory training. This is the first report concerning clinical implementation of a respiratory training system.


Subject(s)
Feasibility Studies , Humans , Reproducibility of Results , Male , Adult , Phantoms, Imaging , Female , Breath Holding , Breathing Exercises/instrumentation , Breathing Exercises/methods , Middle Aged , Respiration , Equipment Design
18.
J Egypt Natl Canc Inst ; 36(1): 11, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38584227

ABSTRACT

BACKGROUND: The moderate deep inspiratory breath hold (mDIBH) is a modality famed for cardiac sparing. Prospective studies based on this are few from the eastern part of the world and India. We intend to compare the dosimetry between mDIBH and free-breathing (FB) plans. METHODS: Thirty-two locally advanced left breast cancer patients were taken up for the study. All patients received a dose of 50 Gy in 25 fractions to the chest wall/intact breast, followed by a 10-Gy boost to the lumpectomy cavity in the case of breast conservation surgery. All the patients were treated in mDIBH using active breath coordinator (ABC). The data from the two dose volume histograms were compared regarding plan quality and the doses received by the organs at risk. Paired t-test was used for data analysis. RESULTS: The dose received by the heart in terms of V5, V10, and V30 (4.55% vs 8.39%) and mean dose (4.73 Gy vs 6.74 Gy) were statistically significant in the ABC group than that in the FB group (all p-values < 0.001). Also, the dose received by the LADA in terms of V30 (19.32% vs 24.87%) and mean dose (32.99 Gy vs 46.65 Gy) were significantly less in the ABC group. The mean treatment time for the ABC group was 20 min, while that for the free-breathing group was 10 min. CONCLUSIONS: Incorporating ABC-mDIBH for left-sided breast cancer radiotherapy significantly reduces the doses received by the heart, LADA, and left and right lung, with no compromise in plan quality but with an increase in treatment time.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Female , Breath Holding , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/radiotherapy , Prospective Studies , Heart , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Organs at Risk
19.
Magn Reson Imaging ; 111: 15-20, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38579974

ABSTRACT

BACKGROUND: In patients who have difficulty holding their breath, a free breathing (FB) respiratory-triggered (RT) bSSFP cine technique may be used. However, this technique may have inferior image quality and a longer scan time than breath-hold (BH) bSSFP cine acquisitions. This study examined the effect of an audiovisual breathing guidance (BG) system on RT bSSFP cine image quality, scan time, and ventricular measurements. METHODS: This study evaluated a BG system that provides audiovisual instructions and feedback on the timing of inspiration and expiration to the patient during image acquisition using input from the respiratory bellows to guide them toward a regular breathing pattern with extended end-expiration. In this single-center prospective study in patients undergoing a clinical cardiac magnetic resonance examination, a ventricular short-axis stack of bSSFP cine images was acquired using 3 techniques in each patient: 1) FB and RT (FBRT), 2) BG system and RT (BGRT), and 3) BH. The 3 acquisitions were compared for image quality metrics (endocardial edge definition, motion artifact, and blood-to-myocardial contrast) scored on a Likert scale, scan time, and ventricular volumes and mass. RESULTS: Thirty-two patients (19 females; median age 21 years, IQR 18-32) completed the study protocol. For scan time, BGRT was faster than FBRT (163 s vs. 345 s, p < 0.001). Endocardial edge definition, motion artifact, and blood-to-myocardial contrast were all better for BGRT than FBRT (p < 0.001). Left ventricular (LV) end-systolic volume (ESV) was smaller (3%, p = 0.02) and LV ejection fraction (EF) was larger (0.5%, p = 0.003) with BGRT than with FBRT. There was no significant difference in LV end-diastolic volume (EDV), LV mass, right ventricular (RV) EDV, RV ESV, and RV EF. Scan times were shorter for BGRT compared to BH. Endocardial edge definition and blood-to-myocardial contrast were better for BH than BGRT. Compared to BH, the LV EDV, LV ESV, RV EDV, and RV ESV were mildly smaller (all differences <7%) for BGRT. CONCLUSIONS: The addition of a BG system to RT bSSFP cine acquisitions decreased the scan time and improved image quality. Further exploration of this BG approach is warranted in more diverse populations and with other free breathing sequences.


Subject(s)
Magnetic Resonance Imaging, Cine , Humans , Magnetic Resonance Imaging, Cine/methods , Female , Male , Adult , Prospective Studies , Respiration , Middle Aged , Respiratory-Gated Imaging Techniques/methods , Heart/diagnostic imaging , Heart Ventricles/diagnostic imaging , Breath Holding , Artifacts , Reproducibility of Results , Audiovisual Aids , Young Adult
20.
Curr Sports Med Rep ; 23(4): 137-142, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38578491

ABSTRACT

ABSTRACT: Present-day diving comes in various forms, from utilizing sophisticated diving equipment to relying solely on one's ability to hold their breath. The diver and physician must be aware of the many common medical conditions and environmental considerations of this unique activity. While barotrauma remains the most common dive-related injury, injuries and accidents also are related to diving equipment-related accidents and exposure to marine flora and fauna. In addition, breath-hold diving, which includes free diving, snorkeling, and tasks, is an activity humans have done for thousands of years for recreation or survival. This article will update the dangers of diving and methods to prevent or treat injuries.


Subject(s)
Barotrauma , Diving , Humans , Diving/adverse effects , Diving/injuries , Barotrauma/etiology , Breath Holding
SELECTION OF CITATIONS
SEARCH DETAIL