1.
Medicine (Baltimore) ; 103(20): e38295, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38758838

ABSTRACT

To assess the diagnostic performance of unenhanced electrocardiogram (ECG)-gated cardiac computed tomography (CT) for detecting myocardial edema, using MRI T2 mapping as the reference standard. This retrospective study protocol was approved by our institutional review board, which waived the requirement for written informed consent. Between December 2017 to February 2019, consecutive patients who had undergone T2 mapping for myocardial tissue characterization were identified. We excluded patients who did not undergo unenhanced ECG-gated cardiac CT within 3 months from MRI T2 mapping or who had poor CT image quality. All patients underwent unenhanced ECG-gated cardiac CT with an axial scan using a third-generation, 320 × 0.5 mm detector-row CT unit. Two radiologists together drew regions of interest (ROIs) in the interventricular septum on the unenhanced ECG-gated cardiac CT images. Using T2 mapping as the reference standard, the diagnostic performance of unenhanced cardiac CT for detecting myocardial edema was evaluated by using the area under the receiver operating characteristic curve with sensitivity and specificity. Youden index was used to find an optimal sensitivity-specificity cutoff point. A cardiovascular radiologist independently performed the measurements, and interobserver reliability was assessed using intraclass correlation coefficients for CT value measurements. A P value of <.05 was considered statistically significant. We included 257 patients who had undergone MRI T2 mapping. Of the 257 patients, 35 patients underwent unenhanced ECG-gated cardiac CT. One patient was excluded from the study because of poor CT image quality. Finally, 34 patients (23 men; age 64.7 ±â€…14.6 years) comprised our study group. Using T2 mapping, we identified myocardial edema in 19 patients. Mean CT and T2 values for 34 patients were 46.3 ±â€…2.7 Hounsfield unit and 49.0 ±â€…4.9 ms, respectively. Mean CT values moderately correlated with mean T2 values (Rho = -0.41; P < .05). Mean CT values provided a sensitivity of 63.2% and a specificity of 93.3% for detecting myocardial edema, with a cutoff value of ≤45.0 Hounsfield unit (area under the receiver operating characteristic curve = 0.77; P < .01). Inter-observer reproducibility in measuring mean CT values was excellent (intraclass correlation coefficient = 0.93; [95% confidence interval: 0.86, 0.96]). Myocardial edema could be detected by CT value of myocardium in unenhanced ECG-gated cardiac CT.


Subject(s)
Electrocardiography , Tomography, X-Ray Computed , Humans , Male , Female , Middle Aged , Retrospective Studies , Electrocardiography/methods , Tomography, X-Ray Computed/methods , Aged , Magnetic Resonance Imaging/methods , Sensitivity and Specificity , Reproducibility of Results , Edema/diagnostic imaging , Edema, Cardiac/diagnostic imaging , Cardiac-Gated Imaging Techniques/methods , ROC Curve , Adult
2.
Physiol Meas ; 45(4)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38599227

ABSTRACT

Objective.In cardiovascular magnetic resonance imaging, synchronization of image acquisition with heart motion (calledgating) is performed by detecting R-peaks in electrocardiogram (ECG) signals. Effective gating is challenging with 3T and 7T scanners, due to severe distortion of ECG signals caused by magnetohydrodynamic effects associated with intense magnetic fields. This work proposes an efficient retrospective gating strategy that requires no prior training outside the scanner and investigates the optimal number of leads in the ECG acquisition set.Approach.The proposed method was developed on a data set of 12-lead ECG signals acquired within 3T and 7T scanners. Independent component analysis is employed to effectively separate components related with cardiac activity from those associated to noise. Subsequently, an automatic selection process identifies the components best suited for accurate R-peak detection, based on heart rate estimation metrics and frequency content quality indexes.Main results.The proposed method is robust to different B0 field strengths, as evidenced by R-peak detection errors of 2.4 ± 3.1 ms and 10.6 ± 15.4 ms for data acquired with 3T and 7T scanners, respectively. Its effectiveness was verified with various subject orientations, showcasing applicability in diverse clinical scenarios. The work reveals that ECG leads can be limited in number to three, or at most five for 7T field strengths, without significant degradation in R-peak detection accuracy.Significance.The approach requires no preliminary ECG acquisition for R-peak detector training, reducing overall examination time. The gating process is designed to be adaptable, completely blind and independent of patient characteristics, allowing wide and rapid deployment in clinical practice. The potential to employ a significantly limited set of leads enhances patient comfort.


Subject(s)
Electrocardiography , Heart , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Heart/diagnostic imaging , Heart/physiology , Image Processing, Computer-Assisted/methods , Signal Processing, Computer-Assisted , Male , Adult , Heart Rate , Cardiac-Gated Imaging Techniques/methods , Female , Retrospective Studies
3.
NMR Biomed ; 37(4): e5091, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38196195

ABSTRACT

BACKGROUND: Despite the widespread use of cine MRI for evaluation of cardiac function, existing real-time methods do not easily enable quantification of ventricular function. Moreover, segmented cine MRI assumes periodicity of cardiac motion. We aim to develop a self-gated, cine MRI acquisition scheme with data-driven cluster-based binning of cardiac motion. METHODS: A Cartesian golden-step balanced steady-state free precession sequence with sorted k-space ordering was designed. Image data were acquired with breath-holding. Principal component analysis and k-means clustering were used for binning of cardiac phases. Cluster compactness in the time dimension was assessed using temporal variability, and dispersion in the spatial dimension was assessed using the Calinski-Harabasz index. The proposed and the reference electrocardiogram (ECG)-gated cine methods were compared using a four-point image quality score, SNR and CNR values, and Bland-Altman analyses of ventricular function. RESULTS: A total of 10 subjects with sinus rhythm and 8 subjects with arrhythmias underwent cardiac MRI at 3.0 T. The temporal variability was 45.6 ms (cluster) versus 24.6 ms (ECG-based) (p < 0.001), and the Calinski-Harabasz index was 59.1 ± 9.1 (cluster) versus 22.0 ± 7.1 (ECG based) (p < 0.001). In subjects with sinus rhythm, 100% of the end-systolic and end-diastolic images from both the cluster and reference approach received the highest image quality score of 4. Relative to the reference cine images, the cluster-based multiphase (cine) image quality consistently received a one-point lower score (p < 0.05), whereas the SNR and CNR values were not significantly different (p = 0.20). In cases with arrhythmias, 97.9% of the end-systolic and end-diastolic images from the cluster approach received an image quality score of 3 or more. The mean bias values for biventricular ejection fraction and volumes derived from the cluster approach versus reference cine were negligible. CONCLUSION: ECG-free cine cardiac MRI with data-driven clustering for binning of cardiac motion is feasible and enables quantification of cardiac function.


Subject(s)
Image Interpretation, Computer-Assisted , Magnetic Resonance Imaging, Cine , Humans , Magnetic Resonance Imaging, Cine/methods , Image Interpretation, Computer-Assisted/methods , Cardiac-Gated Imaging Techniques/methods , Ventricular Function , Cluster Analysis , Reproducibility of Results
4.
Eur Radiol ; 34(8): 4920-4927, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38195730

ABSTRACT

OBJECTIVES: Assessment of myocardial strain by feature tracking magnetic resonance imaging (FT-MRI) in human fetuses with and without congenital heart disease (CHD) using cardiac Doppler ultrasound (DUS) gating. METHODS: A total of 43 human fetuses (gestational age 28-41 weeks) underwent dynamic cardiac MRI at 3 T. Cine balanced steady-state free-precession imaging was performed using fetal cardiac DUS gating. FT-MRI was analyzed using dedicated post-processing software. Endo- and epicardial contours were manually delineated from fetal cardiac 4-chamber views, followed by automated propagation to calculate global longitudinal strain (GLS) of the left (LV) and right ventricle (RV), LV radial strain, and LV strain rate. RESULTS: Strain assessment was successful in 38/43 fetuses (88%); 23 of them had postnatally confirmed diagnosis of CHD (e.g., coarctation, transposition of great arteries) and 15 were heart healthy. Five fetuses were excluded due to reduced image quality. In fetuses with CHD compared to healthy controls, median LV GLS (- 13.2% vs. - 18.9%; p < 0.007), RV GLS (- 7.9% vs. - 16.2%; p < 0.006), and LV strain rate (1.4 s-1 vs. 1.6 s-1; p < 0.003) were significantly higher (i.e., less negative). LV radial strain was without a statistically significant difference (20.7% vs. 22.6%; p = 0.1). Bivariate discriminant analysis for LV GLS and RV GLS revealed a sensitivity of 67% and specificity of 93% to differentiate between fetuses with CHD and healthy fetuses. CONCLUSION: Myocardial strain was successfully assessed in the human fetus, performing dynamic fetal cardiac MRI with DUS gating. Our study indicates that strain parameters may allow for differentiation between fetuses with and without CHD. CLINICAL RELEVANCE STATEMENT: Myocardial strain analysis by cardiac MRI with Doppler ultrasound gating and feature tracking may provide a new diagnostic approach for evaluation of fetal cardiac function in congenital heart disease. KEY POINTS: • MRI myocardial strain analysis has not been performed in human fetuses so far. • Myocardial strain was assessed in human fetuses using cardiac MRI with Doppler ultrasound gating. • MRI myocardial strain may provide a new diagnostic approach to evaluate fetal cardiac function.


Subject(s)
Fetal Heart , Heart Defects, Congenital , Humans , Female , Pregnancy , Heart Defects, Congenital/diagnostic imaging , Fetal Heart/diagnostic imaging , Magnetic Resonance Imaging, Cine/methods , Magnetic Resonance Imaging/methods , Cardiac-Gated Imaging Techniques/methods
5.
Cardiol Young ; 34(4): 838-845, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37877254

ABSTRACT

INTRODUCTION: Identification of paediatric coronary artery abnormalities is challenging. We studied whether coronary artery CT angiography can be performed safely and reliably in children. MATERIALS: Retrospective analysis of consecutive coronary CT angiography scans was performed for image quality and estimated radiation dose. Both factors were assessed for correlation with electrocardiographic-gating technique that was protocoled on a case-by-case basis, radiation exposure parameters, image noise artefact parameters, heart rate, and heart rate variability. RESULTS: Sixty scans were evaluated, of which 96.5% were diagnostic for main left and right coronaries and 91.3% were considered diagnostic for complete coronary arteries. Subjective image quality correlated significantly with lower heart rate, increasing patient age, and higher signal-to-noise ratio. Estimated radiation dose only correlated significantly with choice of electrocardiographic-gating technique with median doses as follows: 2.42 mSv for electrocardiographic-gating triggered high-pitch spiral technique, 5.37 mSv for prospectively triggered axial sequential technique, 3.92 mSv for retrospectively gated technique, and 5.64 mSv for studies which required multiple runs. Two scans were excluded for injection failure and one for protocol outside the study scope. Five non-diagnostic cases were attributed to breathing motion, scanning prior to peak contrast enhancement, or scan acquisition during the incorrect portion of the R-R interval. CONCLUSIONS: Diagnostic-quality coronary CT angiography can be performed reliably with a low estimated radiation exposure by tailoring each scan protocol to the patient's body habitus and heart rate. We propose coronary CT angiography is a safe and effective diagnostic modality for coronary artery abnormalities in children.


Subject(s)
Coronary Artery Disease , Heart Defects, Congenital , Humans , Child , Computed Tomography Angiography/adverse effects , Computed Tomography Angiography/methods , Retrospective Studies , Radiation Dosage , Tomography, X-Ray Computed/methods , Heart , Coronary Artery Disease/diagnostic imaging , Coronary Angiography/adverse effects , Coronary Angiography/methods , Cardiac-Gated Imaging Techniques/methods
6.
Acta Radiol ; 64(5): 2024-2032, 2023 May.
Article in English | MEDLINE | ID: mdl-36451522

ABSTRACT

BACKGROUND: Redoable precise and non-invasive diagnostic imaging modality with the least radiation dose is essential for infants with congenital heart disease (CHD) . PURPOSE: To investigate the accuracy and estimate the radiation dose of our cardiac computed tomography (CCT) protocol. MATERIAL AND METHODS: A total of 82 infants with CHD underwent non-ECG-gated CCT without contrast timing scanning techniques and were retrospectively studied. The image quality and radiation dose were estimated. The radiation dose was compared statistically to virtual retrospective ECG-gated and prospective ECG-triggering scanning modes. The diagnostic accuracy was assessed assuming the surgical results as the diagnostic gold standard. RESULTS: Most exams showed a high quality with low radiation doses compared to previous studies. The mean effective dose (ED) was 0.39 ± 1.2, significantly lower than that of the virtual retrospective ECG-gated and prospective ECG-triggering scanning and lower than in previous studies. Our CCT protocol has achieved a diagnostic accuracy of 99.52% with a sensitivity of 94.83% and specificity of 99.91%. CONCLUSION: Non-ECG-gated CCT without contrast timing techniques can detect the non-coronary cardiovascular defects of CHD in infants with an ultralow radiation dose and a high diagnostic accuracy.


Subject(s)
Heart Defects, Congenital , Multidetector Computed Tomography , Infant , Humans , Retrospective Studies , Prospective Studies , Radiation Dosage , Coronary Angiography/methods , Multidetector Computed Tomography/methods , Heart Defects, Congenital/diagnostic imaging , Electrocardiography , Cardiac-Gated Imaging Techniques/methods
7.
Eur Radiol ; 33(2): 1254-1265, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36098798

ABSTRACT

OBJECTIVES: To validate an artificial intelligence (AI)-based fully automatic coronary artery calcium (CAC) scoring system on non-electrocardiogram (ECG)-gated low-dose chest computed tomography (LDCT) using multi-institutional datasets with manual CAC scoring as the reference standard. METHODS: This retrospective study included 452 subjects from three academic institutions, who underwent both ECG-gated calcium scoring computed tomography (CSCT) and LDCT scans. For all CSCT and LDCT scans, automatic CAC scoring (CAC_auto) was performed using AI-based software, and manual CAC scoring (CAC_man) was set as the reference standard. The reliability and agreement of CAC_auto was evaluated and compared with that of CAC_man using intraclass correlation coefficients (ICCs) and Bland-Altman plots. The reliability between CAC_auto and CAC_man for CAC severity categories was analyzed using weighted kappa (κ) statistics. RESULTS: CAC_auto on CSCT and LDCT yielded a high ICC (0.998, 95% confidence interval (CI) 0.998-0.999 and 0.989, 95% CI 0.987-0.991, respectively) and a mean difference with 95% limits of agreement of 1.3 ± 37.1 and 0.8 ± 75.7, respectively. CAC_auto achieved excellent reliability for CAC severity (κ = 0.918-0.972) on CSCT and good to excellent but heterogenous reliability among datasets (κ = 0.748-0.924) on LDCT. CONCLUSIONS: The application of an AI-based automatic CAC scoring software to LDCT shows good to excellent reliability in CAC score and CAC severity categorization in multi-institutional datasets; however, the reliability varies among institutions. KEY POINTS: • AI-based automatic CAC scoring on LDCT shows excellent reliability with manual CAC scoring in multi-institutional datasets. • The reliability for CAC score-based severity categorization varies among datasets. • Automatic scoring for LDCT shows a higher false-positive rate than automatic scoring for CSCT, and most common causes of a false-positive are image noise and artifacts for both CSCT and LDCT.


Subject(s)
Calcium , Cardiac-Gated Imaging Techniques , Coronary Vessels , Tomography, X-Ray Computed , Humans , Artificial Intelligence , Calcium/analysis , Cardiac-Gated Imaging Techniques/methods , Coronary Vessels/diagnostic imaging , Datasets as Topic , Electrocardiography , Multicenter Studies as Topic , Reproducibility of Results , Retrospective Studies , Tomography, X-Ray Computed/methods
8.
Tomography ; 8(5): 2426-2434, 2022 Sep 28.
Article in English | MEDLINE | ID: mdl-36287800

ABSTRACT

Rationale and Objective: Thoracic CT angiography (CTA) for ascending aortic dissection, a life-threatening emergency, is performed routinely without Electrocardiographic (ECG) gating, therefore allowing the apparition of a pulsation artefact. We aimed to evaluate and compare the diagnostic performance, the inter and intra-reporter agreement of ECG gated CTA and non-ECG gated CTA for detecting ascending aortic dissection, considering their training level. Our hypothesis is that ECG gated CTA has superior diagnostic accuracy for ascending aortic dissection compared to non-gated CTA. Materials and Methods: We collected data using 24 questions survey using clinically validated CT examinations. Sixty-six respondents (medical students, radiology residents, and consultants) blinded to the actual diagnosis independently evaluated the images pertaining to the presence of ascending aortic dissection. The reference standard was represented by clinical and imaging diagnosis. Inter-rater and inter-group concordance was evaluated; the agreement with reference tests was calculated and assessed as a function of reporters' training level. Results: Reporters' ascending aortic dissection assessment showed a better correlation with the reference standard in the ECG gated CTA. The inter-rater correlation was higher in the ECG gated CTA compared to non-ECG gated CTA. Observers' confidence for diagnosing ascending aortic dissection was higher in the ECG gated CTA. Statistically significant differences (p < 0.05) were found between different training levels when assessing non-ECG gated examinations. Conclusions: ECG gated CTA shows a higher diagnostic performance for ascending aortic dissection than non-ECG gated CTA, regardless of the reporters' training level.


Subject(s)
Aortic Dissection , Computed Tomography Angiography , Humans , Computed Tomography Angiography/methods , Cardiac-Gated Imaging Techniques/methods , Electrocardiography/methods , Angiography/methods , Aortic Dissection/diagnostic imaging
9.
Magn Reson Imaging ; 92: 161-168, 2022 10.
Article in English | MEDLINE | ID: mdl-35777685

ABSTRACT

To explore and extend on dynamic imaging of joint motion, an MRI-safe device guiding knee motion with an attached rotary encoder was used in MRI measurements of multiple knee flexion-extension cycles using radial gradient echo imaging with the golden-angle as azimuthal angle increment. Reproducibility of knee motion was investigated. Real-time and CINE mode anatomical images were reconstructed for different knee flexion angles by synchronizing the encoder information with the MRI data, and performing flexion angle selective gating across multiple motion cycles. When investigating the influence of the rotation angle window width on reconstructed CINE images, it was found that angle windows between 0.5° and 3° exhibited acceptable image sharpness without suffering from significant motion-induced blurring. Furthermore, due to flexible retrospective image reconstruction afforded by the radial golden-angle imaging, the number of motion cycles included in the reconstruction could be retrospectively reduced to investigate the corresponding influence of acquisition time on image quality. Finally, motion reproducibility between motion cycles and accuracy of the flexion angle selective gating were sufficient to acquire whole-knee 3D dynamic imaging with a retrospectively gated 3D cone UTE sequence.


Subject(s)
Cardiac-Gated Imaging Techniques , Image Interpretation, Computer-Assisted , Cardiac-Gated Imaging Techniques/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging, Cine/methods , Reproducibility of Results , Retrospective Studies
10.
J Comput Assist Tomogr ; 45(3): 415-420, 2021.
Article in English | MEDLINE | ID: mdl-33797443

ABSTRACT

OBJECTIVES: The aim of this study was to determine the difference and correlation in pulmonary artery (PA) size when measured from the electrocardiogram (ECG)-gated computed tomography (CT) and non-ECG-gated CT. METHODS: In the retrospective study, 279 patients who underwent both ECG-gated CT and non-ECG-gated CT were enrolled. Maximum and minimum diameters of main pulmonary artery (MPA), right pulmonary artery (RPA), and ascending aorta (AAO) were measured, whereas mean diameters of MPA and RPA were obtained. The same PA size parameters were also measured on non-ECG-gated CT. RESULTS: There was a significant difference in maximum and minimum PA diameters between ECG-gated CT and non-ECG-gated CT, whereas mean PA diameters showed no statistically difference. The PA parameters showed a strong positive correlation between these 2 examinations. CONCLUSIONS: The PA size was different between ECG-gated CT and non-ECG-gated CT, whereas the PA size parameters on non-ECG-gated CT could be used to predict those with ECG-gated CT, which allow for confident prediction of pulmonary hypertension and guide further surgical intervention.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Heart Defects, Congenital/diagnostic imaging , Hypertension, Pulmonary/diagnostic imaging , Pulmonary Artery/diagnostic imaging , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Electrocardiography , Female , Heart Defects, Congenital/pathology , Heart Defects, Congenital/physiopathology , Humans , Hypertension, Pulmonary/pathology , Hypertension, Pulmonary/physiopathology , Male , Middle Aged , Pulmonary Artery/pathology , Pulmonary Artery/physiopathology , Retrospective Studies , Sensitivity and Specificity , Young Adult
11.
NMR Biomed ; 34(1): e4420, 2021 01.
Article in English | MEDLINE | ID: mdl-33021342

ABSTRACT

INTRODUCTION: Magnetic resonance elastography (MRE)-derived aortic stiffness is a potential biomarker for multiple cardiovascular diseases. Currently, gradient-recalled echo (GRE) MRE is a widely accepted technique to estimate aortic stiffness. However, multi-slice GRE MRE requires multiple breath-holds (BHs), which can be challenging for patients who cannot consistently hold their breath. The aim of this study was to investigate the feasibility of a multi-slice spin-echo echo-planar imaging (SE-EPI) MRE sequence for quantifying in vivo aortic stiffness using a free-breathing (FB) protocol and a single-BH protocol. METHOD: On Scanner 1, 25 healthy subjects participated in the validation of FB SE-EPI against FB GRE. On Scanner 2, another 15 healthy subjects were recruited to compare FB SE-EPI with single-BH SE-EPI. Among all volunteers, five participants were studied on both scanners to investigate the inter-scanner reproducibility of FB SE-EPI aortic MRE. Bland-Altman analysis, Lin's concordance correlation coefficient (LCCC) and coefficient of variation (COV) were evaluated. The phase-difference signal-to-noise ratios (PD SNR) were compared. RESULTS: Aortic MRE using FB SE-EPI and FB GRE yielded similar stiffnesses (paired t-test, P = 0.19), with LCCC = 0.97. The FB SE-EPI measurements were reproducible (intra-scanner LCCC = 0.96) and highly repeatable (LCCC = 0.99). The FB SE-EPI MRE was also reproducible across different scanners (inter-scanner LCCC = 0.96). Single-BH SE-EPI scans yielded similar stiffness to FB SE-EPI scans (LCCC = 0.99) and demonstrated a low COV of 2.67% across five repeated measurements. CONCLUSION: Multi-slice SE-EPI aortic MRE using an FB protocol or a single-BH protocol is reproducible and repeatable with advantage over multi-slice FB GRE in reducing acquisition time. Additionally, FB SE-EPI MRE provides a potential alternative to BH scans for patients who have challenges in holding their breath.


Subject(s)
Aorta, Abdominal/diagnostic imaging , Cardiac-Gated Imaging Techniques/methods , Elasticity Imaging Techniques/methods , Magnetic Resonance Imaging/methods , Vascular Stiffness , Aorta, Abdominal/physiology , Cardiac-Gated Imaging Techniques/instrumentation , Echo-Planar Imaging/instrumentation , Echo-Planar Imaging/methods , Elasticity Imaging Techniques/instrumentation , Feasibility Studies , Humans , Magnetic Resonance Imaging/instrumentation , Reference Values , Reproducibility of Results , Respiration , Signal-To-Noise Ratio
12.
BMC Med Imaging ; 20(1): 128, 2020 12 09.
Article in English | MEDLINE | ID: mdl-33297985

ABSTRACT

BACKGROUND: Ultra-high field magnetic resonance imaging (MR) may be used to improve intracranial blood flow measurements. However, standard cardiac synchronization methods tend to fail at ultra-high field MR. Therefore, this study aims to investigate an alternative synchronization technique using Doppler ultrasound. METHODS: Healthy subjects (n = 9) were examined with 7T MR. Flow was measured in the M1-branch of the middle cerebral artery (MCA) and in the cerebral aqueduct (CA) using through-plane phase contrast (2D flow). Flow in the circle of Willis was measured with three-dimensional, three-directional phase contrast (4D flow). Scans were gated with Doppler ultrasound (DUS) and electrocardiogram (ECG), and pulse oximetry data (POX) was collected simultaneously. False negative and false positive trigger events were counted for ECG, DUS and POX, and quantitative flow measures were compared. RESULTS: There were fewer false positive triggers for DUS compared to ECG (5.3 ± 11 vs. 25 ± 31, p = 0.031), while no other measured parameters differed significantly. Net blood flow in M1 was similar between DUS and ECG for 2D flow (1.5 ± 0.39 vs. 1.6 ± 0.41, bias ± 1.96SD: - 0.021 ± 0.36) and 4D flow (1.8 ± 0.48 vs. 9 ± 0.59, bias ± 1.96SD: - 0.086 ± 0.57 ml). Net CSF flow per heart beat in the CA was also similar for DUS and ECG (3.6 ± 2.1 vs. 3.0 ± 5.8, bias ± 1.96SD: 0.61 ± 13.6 µl). CONCLUSION: Gating with DUS produced fewer false trigger events than using ECG, with similar quantitative flow values. DUS gating is a promising technique for cardiac synchronization at 7T.


Subject(s)
Blood Flow Velocity , Cardiac-Gated Imaging Techniques/methods , Cerebral Arteries/diagnostic imaging , Ultrasonography, Doppler/methods , Adult , Cerebral Arteries/physiology , Electrocardiography , False Negative Reactions , False Positive Reactions , Female , Humans , Male , Middle Aged , Oximetry , Reference Values , Young Adult
13.
Pediatr Radiol ; 50(10): 1375-1380, 2020 09.
Article in English | MEDLINE | ID: mdl-32696109

ABSTRACT

BACKGROUND: As CT technology has advanced, techniques for pediatric cardiac CT in congenital heart disease have evolved from retrospective electrocardiography (ECG)-gating with relatively high radiation doses to lower-dose prospective ECG-gating and even single-beat gated scans. Despite these advances, coronary artery imaging in children remains challenging because of their small vessel size and high heart rates, often necessitating retrospective gating. OBJECTIVE: Evaluate coronary artery visualization in pediatric patients (<20 years) who underwent low-dose high-pitch ECG-triggered scans and stratify the probability of coronary artery visualization based upon heart rate and body surface area (BSA). MATERIALS AND METHODS: Two hundred eleven high-pitch ECG-triggered studies from April 2014 to November 2017 were reviewed by two pediatric cardiac imagers in this retrospective study. Patient age, gender, BSA, average heart rate, heart rate variability and use of general anesthesia were recorded as well as dose-length product (DLP) and volumetric CT dose index (CTDIvol). We assessed the coronary artery score using a 5-point scale, with score of ≥3 considered of diagnostic quality. We performed multivariate statistical analysis including logistic regression to analyze effects of heart rate and BSA. RESULTS: Patient age range was 1 day to 19 years (median age 3 years). Heart rate range was 49-188 beats per minute (bpm; median 122 bpm) and BSA range was 0.15-2.07 m2 (median 0.53 m2). The origin and proximal coronary arteries were confidently seen (score ≥3) in 61% of studies in this cohort. Coronary artery visualization scores further increased with increased BSA (P<0.002) and with decreased heart rate (P<0.001). At heart rates <100 bpm or in patients with BSA>0.58, adequate coronary artery visualization was present 72% of the time. CONCLUSION: While in many patients the coronary artery origins are visualized using high-pitch ECG-triggered technique, the importance of coronary artery visualization needs to be weighed with the radiation dose penalty in individual patients to achieve optimal imaging.


Subject(s)
Body Surface Area , Cardiac-Gated Imaging Techniques/methods , Coronary Vessels/diagnostic imaging , Heart Defects, Congenital/diagnostic imaging , Heart Rate , Tomography, X-Ray Computed/methods , Adolescent , Child , Child, Preschool , Female , Humans , Infant , Infant, Newborn , Male , Retrospective Studies , Young Adult
14.
J Surg Oncol ; 122(3): 407-411, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32483842

ABSTRACT

BACKGROUND AND OBJECTIVES: Irreversible electroporation (IRE) is a nonthermal electrical tumor ablative strategy for unresectable tumors. IRE is relatively safe around critical structures but may induce cardiac arrhythmia when its delivery is not synchronized to the cardiac cycle. We performed a systematic literature review to determine rates of arrhythmia when IRE was utilized with or without cardiac synchronization. METHODS: An online literature search was conducted with additional hand selection of articles. Data were extracted and pooled analyses were performed. RESULTS: Twelve articles were included in analysis. IRE was performed for 481 patients; 46% hepatic tumors (n = 223), 36% pancreatic lesions (n = 168), and multiple other locations including prostate. Synchronization was performed on 422 patients. Arrhythmias were noted in 3.7% of cases (n = 18/481); cardiac synchronization: 1.2% (n = 5/422) vs unsynchronized: 22.0% (n = 13/59), P < .0001. These events occurred in every organ except the prostate. CONCLUSIONS: IRE remains a potent technology for unresectable tumors, but arrhythmia is a clinical concern. This literature review confirms that cardiac gating should be used in all cases outside of prostate to prevent this potentially serious adverse event.


Subject(s)
Ablation Techniques/statistics & numerical data , Arrhythmias, Cardiac/epidemiology , Electroporation/statistics & numerical data , Liver Neoplasms/surgery , Pancreatic Neoplasms/surgery , Ablation Techniques/adverse effects , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/etiology , Cardiac-Gated Imaging Techniques/methods , Humans
16.
J Nucl Med Technol ; 48(2): 141-142, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32499324
17.
J Neurosurg ; 134(5): 1650-1657, 2020 Jun 05.
Article in English | MEDLINE | ID: mdl-32503002

ABSTRACT

OBJECTIVE: Previous studies have demonstrated the importance of intracranial elastance; however, methodological difficulties have limited widespread clinical use. Measuring elastance may offer potential benefit in helping to identify patients at risk for untoward intracranial pressure (ICP) elevation from small rises in intracranial volume. The authors sought to develop an easily used method that accounts for the changing ICP that occurs over a cardiac cycle and to assess this method in a large-animal model over a broad range of ICPs. METHODS: The authors used their previously described cardiac-gated intracranial balloon pump and swine model of cerebral edema. In the present experiment they measured elastance at 4 points along the cardiac cycle-early systole, peak systole, mid-diastole, and end diastole-by using rapid balloon inflation to 1 ml over an ICP range of 10-30 mm Hg. RESULTS: The authors studied 7 swine with increasing cerebral edema. Intracranial elastance rose progressively with increasing ICP. Peak-systolic and end-diastolic elastance demonstrated the most consistent rise in elastance as ICP increased. Cardiac-gated elastance measurements had markedly lower variance within swine compared with non-cardiac-gated measures. The slope of the ICP-elastance curve differed between swine. At ICP between 20 and 25 mm Hg, elastance varied between 8.7 and 15.8 mm Hg/ml, indicating that ICP alone cannot accurately predict intracranial elastance. CONCLUSIONS: Measuring intracranial elastance in a cardiac-gated manner is feasible and may offer an improved precision of measure. The authors' preliminary data suggest that because elastance values may vary at similar ICP levels, ICP alone may not necessarily best reflect the state of intracranial volume reserve capacity. Paired ICP-elastance measurements may offer benefit as an adjunct "early warning monitor" alerting to the risk of untoward ICP elevation in brain-injured patients that is induced by small increases in intracranial volume.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Compliance , Intracranial Hypertension/physiopathology , Intracranial Pressure , Animals , Biological Variation, Individual , Brain Edema/complications , Brain Edema/physiopathology , Diastole , Encephalocele/etiology , Encephalocele/prevention & control , Equipment Design , Female , Intracranial Hypertension/etiology , Swine , Systole , Translational Research, Biomedical
18.
World Neurosurg ; 138: 706-713, 2020 06.
Article in English | MEDLINE | ID: mdl-31917307

ABSTRACT

In this paper, 64-slice spiral computed tomography (CT) retrospective electrocardiographic (ECG) gating technology was used to perform coronary CT angiography scans. The aorta and aortic pulmonary artery diameter were measured quantitatively in healthy people and patients with hypertension and cerebrovascular disease. Corresponding aortic pulmonary artery ratios were obtained through calculation, and the changes of aortic diameter, aortic pulmonary artery ratio, and aortic diameter difference between different cardiac phases, ages, sexes, and levels of hypertension were discussed. Through research, it can be concluded that 64-row spiral CT scan combined with ECG gating technology can accurately measure the dynamic changes of the aortic diameter with the cardiac cycle. At the same time, the aortic diameter measured by multidetector CT scan combined with ECG gating technology and the phase difference between different phases can objectively reflect the degree of arterial damage in patients with hypertension; therefore, early screening of aortic diseases in patients with hypertension can be performed. Diagnosis to detect abnormalities as early as possible and start treatment as early as possible to prevent the disease from progressing and even affecting other tissues and organs can also be obtained.


Subject(s)
Aorta/diagnostic imaging , Cardiac-Gated Imaging Techniques/methods , Computed Tomography Angiography/methods , Hypertension/diagnostic imaging , Pulmonary Artery/diagnostic imaging , Tomography, Spiral Computed/methods , Adult , Aged , Aged, 80 and over , Aorta/pathology , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/pathology , Case-Control Studies , Coronary Angiography/methods , Diastole , Electrocardiography , Female , Humans , Hypertension/pathology , Male , Middle Aged , Multidetector Computed Tomography , Organ Size , Pulmonary Artery/pathology , Sinus of Valsalva/diagnostic imaging , Sinus of Valsalva/pathology , Systole , Tomography, X-Ray Computed
19.
J Magn Reson Imaging ; 51(1): 260-272, 2020 01.
Article in English | MEDLINE | ID: mdl-31228302

ABSTRACT

BACKGROUND: Fetal cardiovascular MRI complements ultrasound to assess fetal cardiovascular pathophysiology. PURPOSE: To develop a free-breathing method for retrospective fetal cine MRI using Doppler ultrasound (DUS) cardiac gating and tiny golden angle radial sampling (tyGRASP) for accelerated acquisition capable of detecting fetal movements for motion compensation. STUDY TYPE: Feasibility study. SUBJECTS: Nine volunteers (gestational week 34-40). Short-axis and four-chamber views were acquired during maternal free-breathing and breath-hold. FIELD STRENGTH/SEQUENCE: 1.5T cine balanced steady-state free precession. ASSESSMENT: A self-gated reconstruction method was improved for clinical application by using 1) retrospective DUS gating, and 2) motion detection and rejection/correction algorithms for compensating for fetal motion. The free-breathing reconstructions were qualitatively and quantitatively assessed, and DUS-gating was compared with self-gating in breath-hold reconstructions. A scoring of 1-4 for overall image quality, cardiac, and extracardiac diagnostic quality was used. STATISTICAL TESTS: Friedman's test was used to assess differences in qualitative scoring between observers. A Wilcoxon matched-pairs signed rank test was used to assess differences between breath-hold and free-breathing acquisitions and between observers' quantitative measurements. RESULTS: In all cases, 111 free-breathing and 145 breath-hold acquisitions, the automatically calculated DUS-based cardiac gating signal provided reconstructions of diagnostic quality (median score 4, range 1-4). Free-breathing did not affect the DUS-based cardiac gated retrospective radial reconstruction with respect to image or diagnostic quality (all P > 0.06). Motion detection with rejection/correction in k-space produced high-quality free-breathing DUS-based reconstructions [median 3, range (2-4)], whereas free-breathing self-gated methods failed in 80 out of 88 cases to produce a stable gating signal. DATA CONCLUSION: Free-breathing fetal cine cardiac MRI based on DUS gating and tyGRASP with motion compensation yields diagnostic images. This simplifies acquisition for the pregnant woman and thus could help increase fetal cardiac MRI acceptance in the clinic. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:260-272.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Fetal Heart/anatomy & histology , Magnetic Resonance Imaging/methods , Ultrasonography, Prenatal/methods , Feasibility Studies , Female , Humans , Motion , Pregnancy , Respiration
20.
Pediatr Radiol ; 50(2): 180-187, 2020 02.
Article in English | MEDLINE | ID: mdl-31853572

ABSTRACT

BACKGROUND: Pediatric cardiac computed tomography (CT) can be acquired without electrode placement by using synthetic electrocardiogram (ECG). OBJECTIVE: To determine whether the depiction of gross cardiac structures and coronary arteries in 320-row pediatric CT is not inferior when CT is gated with synthetic ECG at 150 beats per minute (bpm), compared to the patients' own ECG. MATERIALS AND METHODS: Sixty 320-row CT examinations performed in children younger than 3 years old with congenital cardiac anomaly were enrolled in this retrospective study. Thirty examinations were scanned using the children's own ECG for gating and 30 examinations were scanned using synthetic ECG at 150 bpm. The image quality was compared between the two gating modes using a 3-point scale to delineate the following anatomical structures: atrial septum, ventricular septum, right atrium, right ventricle, left atrium, left ventricle, main pulmonary artery, ascending aorta, aortic arch including the patent ductus arteriosus, descending aorta, right coronary artery and left main trunk. Beam-hardening artifacts from contrast enhancement material were evaluated using a 3-point scale, and the overall image quality was evaluated using a 5-point scale. RESULTS: Synthetic ECG was not inferior to the patients' ECG in depicting each structure, beam-hardening artifact and overall image quality. Average indices were clinically acceptable imaging quality, except for subjective image quality of mid and distal coronary arteries. CONCLUSION: Pediatric cardiac CT in patients younger than 3 years old can be acquired using synthetic ECG gating, with image quality not inferior to the patients' ECG.


Subject(s)
Cardiac-Gated Imaging Techniques/methods , Electrocardiography/methods , Heart Defects, Congenital/diagnostic imaging , Tomography, X-Ray Computed/methods , Female , Humans , Infant , Infant, Newborn , Male , Retrospective Studies